This document is a Bulk Installation Inspection Form used by the Department of Veterans Affairs (VA) to evaluate the condition of medical bulk liquid oxygen and nitrous oxide systems. It covers a comprehensive inspection of the main vessel, reserve tank or cylinders, vaporizers, regulators, alarms, and other equipment. Key details include evaluating the overall site conditions, vessel condition, equipment condition, medical system requirements, and new installation checklist items. The form is used to document the annual inspection of these critical medical gas systems to ensure they are in proper working order and compliant with relevant safety standards. It provides a standardized process for the VA to maintain the integrity and functionality of their medical gas infrastructure.

View the file

Other files

File Type Posted
36C24724Q0538 0002.pdf PDF
36C24724Q0538 0001.docx DOCX document
36C24724Q0538 (005).pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bulk Installation Inspection Form - MED - Rev 02-28-20 Page 1

MEDICAL ANNUAL INSPECTION FORM Work Order #:

BULK SUPPLY SYSTEM Onsite Time (hr):

Travel Time (hr):

Inspection Date: Type of Inspection: Initial PM Customer Owned: Yes No

Customer: Account: Contact: Phone:

Address: City: State: ZIP:

Product: Location Type: Outdoor Indoor Courtyard

MAIN VESSEL INFORMATION

Tank Code: NB#: S/N: MFR Name:

Tank Size: MAWP: Rehab Date: MFR Year:

PSV Inlet Size: BD Inlet Size:

PSV Outlet Size: BD Outlet Size: Telemetry Type: Level Gauge Full: in.

PSV Set Point: BD Set Point: BAM# or FF#: Level Gauge Reorder: in.

RESERVE SUPPLY INFORMATION

Type: Cylinders Vessel For Reserve Cylinders, Qty: Cylinder Size: 9" x 55" 9" x 51"

For Reserve Vessel, Fill Out Information Below (Cylinder Height Excludes Valve)

Tank Code: NB#: S/N: MFR Name:

Tank Size: MAWP: Rehab Date: MFR Year:

PSV Inlet Size: BD Inlet Size:

PSV Outlet Size: BD Outlet Size: BAM Buddy: Yes No Level Gauge Full: in.

PSV Set Point: BD Set Point: Level Gauge Reorder: in.

1 OVERALL SITE CONDITION YES NO N/A NOTES/COMMENTS

1.1 Adequate trailer access, clear for safe delivery? (clear

line of sight, less than 25’ from trailer to fill valves)?

1.2 Adequate lighting for night time deliveries?

1.3 Site secured, fenced, and gates are locked?

1.4 Vessel and system is protected where exposed to

vehicle impact by bollards or other approved means?

1.5 Site has adequate ventilation or mitigation (vents

captured, etc.) if indoor or courtyard installation?

1.6 Adequate and safe access to service equipment? (3'

around vessel and other equipment)

1.7 Pipe supports anchored, pipe clamps tight, and unistrut

stand plastic caps installed?

1.8 Vessel, vaporizers, and equipment anchored?

1.9 Vessel and equipment concrete pad is in good condition

(no serious spalling, cracks, frost heaves, etc.)

1.10 Site has adequate drainage?

Bulk Installation Inspection Form - MED - Rev 02-28-20 Page 2

1.11 Pressure relief devices installed between block valves

and discharge in a safe direction?

1.12 Electrical equipment and conduit in good condition (no

signs of damage, labeled, etc.)?

1.13 System piping and components leak checked and free

of leaks?

1.14 Overall site condition is free of debris, chemical storage, combustibles, or other hazards?

1.15 Exposure distances comply with NFPA 55 and Airgas

Standards (NFPA Distances Table)?

1.16 Concrete off-load pad is installed, in good condition, and free of combustibles for O2 or N2O installations?

1.17 “No Smoking” signs posted for O2 or N2O installations?

1.18 Grounding system (if installed for O2 and N2O tanks, lightning protection, etc.) is in good condition and tight?

1.19 Telemetry system is functioning properly and solar

panel cleaned (if appl.)?

2 VESSEL CONDITION MAIN TANK RESERVE TANK NOTES/COMMENTS

(If no reserve tank, leave those columns unchecked) YES NO YES NO

2.1 Vessel cosmetic condition (paint, dirt, logo, etc.) is

adequate?

2.2 All required Airgas, NFPA, and warning decals are in

place, correct, and legible?

2.3 Tank code is legibly stenciled or labeled on vessel

(verify code if instructed)?

2.4 Vessel has pressure relief device on the fill line?

2.5 Pressure gauges are functional and legible?

2.6 Liquid level gauge is functional, legible, zero checked, and has "reorder" and "full" arrows?

2.7 Vessel has no signs of poor vacuum such as venting, cold spots, etc; (take vacuum reading if suspect)?

2.8 Fill connection correct, in good condition, and equipped

with dust or pressure cap?

2.9 Fill line check valve is installed & operationally checked by safely opening top fill valve to check back-flow?

2.10 Hose drain and full trycock valves are installed and

working properly?

2.11 Pressure building system tested and is operating

correctly at system set point per data label?

2.12 All valve handles are in good working order and valves

tagged properly?

2.13 Vessel has diverter assembly with dual PSVs/BDs?

Cycle to both sides to check flow and for any leaks.

2.14 Vessel PSVs are in good condition, legible, seals intact, and have no signs of weeping?

2.15 Vessel PSVs marked test date will be less than 5 years

old at time of next PM (capture test date)

Test Date:

2.16 Vessel PSVs are secure, free from obstruction, and

venting towards ground or safe location?

2.17 Vessel burst disks (BDs) visually inspected; set point < 150% tank MAWP, good condition, and not weeping?

Bulk Installation Inspection Form - MED - Rev 02-28-20 Page 3

EQUIPMENT INFORMATION

Main Vaporizer Type: Vap. Qty.: Vap. MFR: Vap. Model #:

Reserve Vap. Type: Vap. Qty.: Vap. MFR: Vap. Model #:

PCM Type: Liq Main/Liq Reserve Reg. Size: Reg. MFR: Reg. Model:

Liq Main/Cyl Reserve Delivery Pressure Set Point: Final Line PSV SetPt:

Auxiliary Manifold (Hyperbarics): Yes No Aux Manifold Set Point: Aux PSV Set Point:

Vaporizer Switching Manifold: Yes No Local Alarm Light Panel: Yes No

Other Equip. Notes:

3 EQUIPMENT CONDITION YES NO N/A NOTES/COMMENTS

3.1 Piping material and/or insulation is correct for the

service and in good working condition?

3.2 Process vaporizers at least 50% free of ice build up?

3.3 Vaporizer switching (if installed) verified for proper

operation?

3.4 Vaporizers are protected with thermal PSV and

inspected for set point, orientation, and condition?

3.5 Line regulators are inspected and checked for proper

operation and set point?

3.6 Final line PSV inspected and is in good condition, legible, and has no signs of weeping?

4 MEDICAL SYSTEM REQUIREMENTS YES NO N/A NOTES/COMMENTS

4.1 Bulk system alarm contacts are wired to the facility?

4.2 Discussed with facility their requirements to test

alarms?

4.3 Main vessel low level alarm signal works correctly? Set Point:

4.4 Reserve-in-use alarm signal works correctly? Set Point:

4.5 Reserve vessel low pressure alarm or reserve cylinders

low pressure alarm works correctly? Set Point:

4.6 Reserve vessel low level alarm works correctly? Set Point:

4.7 Local alarm light panel (if installed) functions properly?

4.8 Emergency oxygen supply connection (EOSC)

installed? (N/A for stand-alone hyperbarics facility.)

4.9 Cylinder Reserve: In acceptable condition, with legible

product label and lot number, and properly secured?

4.10 Cylinder Reserve: Pressure is acceptable (not

depleted)? Consider replacing if ~1900 psig. Pressure:

4.11 System will automatically switch to the reserve supply?

4.12 System verified to be free of unauthorized changes?

Bulk Installation Inspection Form - MED - Rev 02-28-20 Page 4

5 NITROUS OXIDE AND CARBON DIOXIDE YES NO N/A NOTES/COMMENTS

5.1 Each fill connection has blow down valve at the CGA

connection and hose restraint cable in good condition?

5.2 Electrical disconnects appear to be in good condition

and no visual signs of blown fuses, loose conduit?

5.3 Refrigeration unit and compressor verified for proper

operation and maintained per MFR recommendations?

MFR and Size:

Refrignt Type:

5.4 Vessel pressure is above 250 psig and within design

range on data label? Record pressure in notes. Pressure:

5.5 Pressure building system tested and is operating

correctly at system set point per data label?

5.6 N2O only: 240 V power plug with disconnect and

grounding source for N2O truck are in good condition?

6 NEW INSTALLATION CHECKLIST YES NO N/A NOTES/COMMENTS

6.1 All field piping is pressure and leak tested to 110% of

design pressure per ASME B31.3?

6.2 Vessel and equipment anchored per standard or

engineered pad drawings?

6.3 All piping, fittings, and equipment installed for O2

service are verified clean for oxygen service?

6.4 Installations with P&ID are installed per design, any

modifications approved, and as-built verified?

6.5 Vessel first-filled and system purged with intended

product?

6.6 Vessel and system set points meet design and

customer requirements?

6.7 Regulator strainers checked for debris and lines purged

if neccessary?

6.8 Site, Vessel, and Equipment requirements in checklist

sections above are in compliance?

COMMENTS:

Technician Name: Customer Name:

Technician Signature: Customer Signature:

Textfield:
Textfield-0: 1.5
Textfield-1: .5
Textfield-2: 7 SEP 2023
PM: Off
Customer Owned Yes: On
No: Off
ChkBox: On
Textfield-3: EAGLE HOME DEPT OF VA COLUMBIA
Textfield-4: 6439 GARNERS FERRY RD
Textfield-5: 2731936
Textfield-6: COLUMBIA
Textfield-7: Joe Chipps
Textfield-8: SC
Textfield-9: (803) 776-4000
Textfield-10: 29209-1638
Textfield-11: OX USPBLK
Indoor: On
Courtyard: Off
ChkBox-0: On
Textfield-12: 51599
Textfield-13: 3000 G
Textfield-14: 23252
Textfield-15: 250
Textfield-16: 3/4
Textfield-17: 3/4
Textfield-18: 375
Textfield-19: 1779M
Textfield-20: NA
Textfield-21: CHART
Textfield-22: 1989
Textfield-23: 1
Textfield-24: 1.25
Textfield-25: 245
Textfield-26: BAM
Textfield-27: 5016 0000 1703
Textfield-28: 140
Textfield-29: 50
Vessel: Off
For Reserve Cylinders Qty: On
Textfield-30: NA
9x51 a: Off
Textfield-31: 56160
Textfield-32: 260 G
Textfield-33: 216146
Textfield-34: 250
Textfield-35: 3/4
Textfield-36: 3/4
Textfield-37: 353
Textfield-38: 31016730
Textfield-39: NA
Textfield-40: CHART
Textfield-41: 2010
Textfield-42: 1/2
Textfield-43: 3/4
Textfield-44: 250
No-0: Off
Level Gauge Full: On
Textfield-45: 58
Textfield-46: 25
Textfield-47:
11-1:
ChkBox-3: On
ChkBox-4: Off
12:
13-1:
ChkBox-5: On
ChkBox-6: Off
14:
U: On
Textfield-48:
16-1:
ChkBox-7: On
ChkBox-8: Off
17:
18-1:
ChkBox-9: On
ChkBox-10: Off
19:
110-1:
Textfield-51:
ChkBox-11: On
ChkBox-12: Off
ChkBox-13: Off
Textfield-52:
113:
114-1:
ChkBox-14: On
ChkBox-15: Off
115:
116-2:
ChkBox-16: On
ChkBox-17: Off
ChkBox-18: Off
117:
118-2:
ChkBox-19: On
ChkBox-20: Off
ChkBox-21: Off
119:
ChkBox-26: On
ChkBox-27: Off
ChkBox-28: On
ChkBox-29: Off
21:
22-3:
ChkBox-30: On
ChkBox-31: Off
ChkBox-32: On
ChkBox-33: Off
23:
24-3:
ChkBox-34: On
ChkBox-35: Off
ChkBox-36: On
ChkBox-37: Off
25:
26-2:
n: On
27:
ChkBox-38: On
ChkBox-39: Off
ChkBox-40: On
ChkBox-41: Off
28:
29-3:
ChkBox-42: On
ChkBox-43: Off
ChkBox-44: On
ChkBox-45: Off
210:
211-2:
ChkBox-46: On
ChkBox-47: Off
ChkBox-48: On
ChkBox-49: Off
212:
213-3:
214-3:
ChkBox-50: On
ChkBox-51: Off
ChkBox-52: On
Date: Off
Date Test: 7.2019
216-2:
ChkBox-53: On
ChkBox-54: Off
ChkBox-55: On
ChkBox-56: Off
217:
Textfield-54: AMBIENT
Textfield-55: NA
Textfield-56: 2
Textfield-57:
Textfield-58: 1"
Textfield-59: CRYOQUIP
Textfield-60:
Textfield-61: REGO
Textfield-62: 52
Textfield-63: 50
Textfield-64: VAIHO8FBL3M
Textfield-65:
Textfield-66: BR1788B
Liq MainLiq Reserve Reg Size: On
Liq MainCyl Reserve: Off
Textfield-67: 75
Textfield-68: 75
No-1: Off
Aux Manifold Set Point: Off
No-2: Off
Local Alarm Light Panel Yes: On
No-3: On
ChkBox-57: Off
Textfield-69:
ChkBox-60: On
ChkBox-61: Off
Textfield-71:
32-2:
ChkBox-62: On
ChkBox-63: Off
ChkBox-64: Off
33:
34-2:
ChkBox-65: On
ChkBox-66: Off
ChkBox-67: Off
35:
U-0: On
36:
41-1:
ChkBox-68: On
ChkBox-69: Off
42:
Set Point: 30"
ChkBox-70: On
Set Point-0: Off
Set Point-1: 80 PSI
Set Point-2: 100 PSI
ChkBox-71: On
ChkBox-72: Off
Set Point-3: Off
Set Point-4: 25"
ChkBox-73: On
ChkBox-74: Off
ChkBox-75: Off
47:
48-2:
ChkBox-76: Off
ChkBox-77: Off
ChkBox-78: On
49:
Pressure:
ChkBox-79: On
ChkBox-80: Off
411:
412-1:
51-2:
ChkBox-81: Off
ChkBox-82: Off
ChkBox-83: On
52:
Refrignt Type MFR and Size:
Pressure-0:
ChkBox-84: Off
ChkBox-85: Off
ChkBox-86: On
55:
56-2:
ChkBox-87: Off
ChkBox-88: Off
ChkBox-89: On
61:
62-2:
ChkBox-90: Off
ChkBox-91: Off
ChkBox-92: On
63:
64:
65-2:
ChkBox-93: Off
ChkBox-94: Off
ChkBox-95: On
66:
67-2:
ChkBox-96: Off
ChkBox-97: Off
ChkBox-98: On
68:
COMMENTS:
Textfield-72: Wevone Hobbs SOBLK348
Textfield-73:
Textfield-74: Joe Chipps
Textfield-75:
CheckBox1: Off
CheckBox2: Yes
CheckBox3: Off
CheckBox4: Yes
CheckBox5: Off
CheckBox6: Off
CheckBox7: Off
CheckBox8: Off
CheckBox9: Yes
CheckBox10: Yes
CheckBox11: Off
CheckBox12: Yes
CheckBox13: Off
CheckBox14: Yes
CheckBox15: Off
CheckBox16: Yes
CheckBox17: Off
CheckBox18: Yes
CheckBox19: Off
CheckBox20: Yes
CheckBox21: Off
CheckBox22: Off
CheckBox23: Yes
CheckBox24: Off
CheckBox25: Off
CheckBox26: Yes
CheckBox27: Off
CheckBox28: Yes
CheckBox29: Off
CheckBox30: Yes
CheckBox31: Off
CheckBox32: Off
CheckBox33: Off
CheckBox34: Yes
CheckBox35: Off
CheckBox36: Yes
CheckBox37: Off
CheckBox38: Off
CheckBox39: Yes
CheckBox40: Off
CheckBox41: Yes
CheckBox42: Off
CheckBox43: Yes
CheckBox44: Off
CheckBox45: Yes
CheckBox46: Off
CheckBox47: Yes
CheckBox48: Off
CheckBox49: Yes
CheckBox50: Off
CheckBox51: Yes
CheckBox52: Off
CheckBox53: Yes
CheckBox54: Off
CheckBox55: Yes
CheckBox56: Off
CheckBox57: Yes
CheckBox58: Off
CheckBox59: Yes
CheckBox60: Off
CheckBox61: Yes
CheckBox62: Off
CheckBox63: Off
CheckBox64: Off
CheckBox65: Off
CheckBox66: Yes
CheckBox67: Off
CheckBox68: Off
CheckBox69: Yes
CheckBox70: Off
CheckBox71: Yes
CheckBox72: Off
CheckBox73: Yes
CheckBox74: Off
CheckBox75: Yes
CheckBox76: Off
CheckBox77: Off
CheckBox78: Off
CheckBox79: Off
CheckBox80: Yes
CheckBox81: Yes
CheckBox82: Off
CheckBox83: Off
CheckBox84: Off
CheckBox85: Yes
CheckBox86: Off
CheckBox87: Off
CheckBox88: Yes
CheckBox89: Off
CheckBox90: Off
CheckBox91: Yes
CheckBox92: Off
CheckBox93: Off
CheckBox94: Yes
CheckBox95: Off
CheckBox96: Off
CheckBox97: Yes
CheckBox98: Off
CheckBox99: Off
CheckBox100: Yes
CheckBox101: Off
CheckBox102: Off
CheckBox103: Yes
CheckBox104: Off
CheckBox105: Off
CheckBox106: Yes