36C24719B0004-0001003.pdf
PDF 11 MB Posted
- Solicitation number
- 36C24719B0004
About this file
36C24719B0004 0001 521-17-101 Combined Drawings_Part3.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24719B0004-0004000.docx | DOCX document | |
| 36C24719B0004-0003000.docx | DOCX document | |
| 36C24719B0004-0002002.pdf | ||
| 36C24719B0004-0002003.pdf | ||
| 36C24719B0004-0002001.pdf | ||
| 36C24719B0004-0002000.docx | DOCX document | |
| 36C24719B0004-0001001.pdf | ||
| 36C24719B0004-0001000.docx | DOCX document | |
| 36C24719B0004-0001002.pdf | ||
| 36C24719B0004-000.docx | DOCX document | |
| 36C24719B0004.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P-708
P-402
AC
AC
PHARMACY
OFFICE
1101B
CLOSET
1101A-A
BF
ROOF
CORRIDOR
OFFICE
1101B
CLOSET
1101A-A
OFFICE
OPEN
OFFICE
DLB DLB
A. CONTRACTOR SHALL REMOVE AND REPAIR PORTIONS OF FLOORS,
CEILINGS AND/OR SLABS AFFECTED BY PLUMBING MODIFICATIONS.
REPAIR SURFACES TO MATCH EXISTING UNLESS NOTED OTHERWISE
ON ARCHITECTURAL DRAWINGS.
B. CONTRACTOR SHALL INSPECT AND ROD OUT EXISTING SANITARY
WASTE AND/OR SEWER PIPING BEFORE MAKING ANY NEW
CONNECTIONS. CONTRACTOR SHALL NOTIFY COR OF ALL SANITARY
SEWER WHICH IS NOT SERVICEABLE AND REQUIRE REPLACEMENT.
C. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING
CODE, LOCAL CODE, AND/OR WHERE HORIZONTAL SANITARY SEWER
PIPING CHANGES DIRECTION OVER 45°. NO CLEANOUT(S) WILL BE
ALLOWED ABOVE CEILING UNLESS NOTED OTHERWISE.
D. NEW 2" SANITARY SEWER PIPING SHALL BE SLOPED A MINIMUM TWO
PERCENT, ONE-QUARTER INCH PER FOOT. NEW 3" AND 4" SANITARY
SEWER PIPING SHALL BE SLOPED A MINIMUM ONE PERCENT,
ONE-EIGHTH INCH PER FOOT.
NEW WORK NOTES FOR THIS DRAWING ONLY
1. CONNECT NEW DOMESTIC COLD WATER SUPPLY PIPING TO EXISTING
DOMESTIC COLD WATER SUPPLY RISER IN PIPE CHASE ABOVE FIRST
FLOOR CEILING LEVEL AT APPROXIMATE LOCATION INDICATED.
2. CONNECT NEW DOMESTIC HOT WATER SUPPLY PIPING TO EXISTING
DOMESTIC HOT WATER SUPPLY RISER IN PIPE CHASE ABOVE FIRST
FLOOR CEILING LEVEL AT APPROXIMATE LOCATION INDICATED.
3. CONNECT NEW VENT PIPING TO EXISTING VENT STACK IN PIPE CHASE
ABOVE FIRST FLOOR CEILING LEVEL AT APPROXIMATE LOCATION
INDICATED.
4. CONNECT NEW SANITARY SEWER PIPING TO EXISTING SANITARY
SEWER STACK BELOW FLOOR IN PIPE CHASE ABOVE BASEMENT
CEILING LEVEL AT APPROXIMATE LOCATION INDICATED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018Revisions: Date:
440 Martin Luther King Jr. Blvd
Macon, GA 31201
478.743.8415 Fax: 478.743.8239
www.clarknexsen.com
KEY PLAN
N.T.S.
GENERAL NOTES
FLOOR PIPING PLAN
PHASE 1 PARTIAL FIRST
FLOOR PIPING PLAN
PHASE 2 PARTIAL FIRST
DLB DLB
PARTIAL SECOND FLOOR PIPING PLAN PARTIAL SECOND FLOOR ROOF PIPING PLAN
A. CONTRACTOR SHALL REMOVE AND REPAIR PORTIONS OF FLOORS,
CEILINGS AND/OR SLABS AFFECTED BY PLUMBING MODIFICATIONS.
REPAIR SURFACES TO MATCH EXISTING UNLESS NOTED OTHERWISE
ON ARCHITECTURAL DRAWINGS.
B. CONTRACTOR SHALL INSPECT AND ROD OUT EXISTING SANITARY
WASTE AND/OR SEWER PIPING BEFORE MAKING ANY NEW
CONNECTIONS. CONTRACTOR SHALL NOTIFY COR OF ALL SANITARY
SEWER WHICH IS NOT SERVICEABLE AND REQUIRE REPLACEMENT.
C. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING
CODE, LOCAL CODE, AND/OR WHERE HORIZONTAL SANITARY SEWER
PIPING CHANGES DIRECTION OVER 45°. NO CLEANOUT(S) WILL BE
ALLOWED ABOVE CEILING UNLESS NOTED OTHERWISE.
D. NEW 2" SANITARY SEWER PIPING SHALL BE SLOPED A MINIMUM TWO
PERCENT, ONE-QUARTER INCH PER FOOT. NEW 3" AND 4" SANITARY
SEWER PIPING SHALL BE SLOPED A MINIMUM ONE PERCENT,
ONE-EIGHTH INCH PER FOOT.
E. ALL HORIZONTAL STORM DRAINAGE PIPING, RAIN WATER LEADER, AND
BOTTOM OF ROOF DRAIN SHALL BE INSULATED.
NEW WORK NOTES FOR THIS DRAWING ONLY
1. H.V.A.C. EQUIPMENT. REFER TO MECHANICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
2. PROVIDE AND INSTALL NEW 3" VENT THRU ROOF.
3. PROVIDE AND INSTALL NEW 4" HUB DRAIN. SET HUB RIM 2" ABOVE
ROOF.
4. PROVIDE AND INSTALL NEW 1" REDUCE PRESSURE BACKFLOW
PREVENTION ASSEMBLY.
5. CONNECT NEW SANITARY SEWER PIPING TO EXISTING SANITARY
SEWER STACK ABOVE SECOND FLOOR CEILING LEVEL AT
APPROXIMATE LOCATION INDICATED.
6. CONNECT NEW VENT PIPING TO EXISTING VENT PIPING ABOVE
SECOND FLOOR CEILING LEVEL AT APPROXIMATE LOCATION
INDICATED.
7. CONNECT 1" DOMESTIC COLD WATER SUPPLY TO EXISTING DOMESTIC
WATER STACK ABOVE SECOND FLOOR CEILING IN PIPING CHAS.
8. 1"DCWS-UP.
9. 1"DCWS-DN. HEAT TRACE ALL PIPING ON ROOF AND IN HVAC UNIT
REFER TO ELECTRICAL FOR ADDITIONAL INFORMATION.
10. 2"V-UP TO VENT THRU ROOF.
11. 3"V-UP TO VENT THRU ROOF.
12. 4"SS-P-TRAP FOR HUB DRAIN ON ROOF.
13. 1"DCWS FOR H.V.A.C. MAKE-UP WATER. REFER TO MECHANICAL
DRAWINGS FOR ADDITIONAL INFORMATION.
14. PROVIDE AND INSTALL 3/4" HOSE BIB.
15. PROVIDE AND INSTALL NEW 3" ROOF DRAIN.
16. CONNECT NEW 4" STORM DRAINAGE PIPING TO EXISTING STORM
DRAINAGE PIPING ABOVE SECOND FLOOR CEILING AT APPROXIMATE
LOCATION INDICATED.
17. 3"SD-UP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018Revisions: Date:
440 Martin Luther King Jr. Blvd
Macon, GA 31201
478.743.8415 Fax: 478.743.8239
www.clarknexsen.com
KEY PLAN
N.T.S.
GENERAL NOTES
DLB DLB
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018Revisions: Date:
440 Martin Luther King Jr. Blvd
Macon, GA 31201
478.743.8415 Fax: 478.743.8239
www.clarknexsen.com
PENDENT
SPRINKLER
ESCUTCHEON
PLATE
ESCUTCHEON
RETAINER
CAULK
PERIMETER
RETURN BEND DROP TO PENDENT SPRINKLER
HEAD FOR USP CLEAN ROOM DETAIL
NONE
1" DROP
NIPPLE
1"x1/2" REDUCER
COUPLING
GYP BOARD
CEILING
SPRINKLER
MAIN SUPPLY
PIPING
CAULK PERIMETERGYP BOARD
CEILING
RETURN BEND DROP TO
PENDENT SPRINKLER HEAD DETAIL
NONE
1" DROP
NIPPLE
1"x1/2" REDUCER
COUPLING
PENDENT
SPRINKLER
TILE CEILING
ESCUTCHEON
PLATE
SPRINKLER
MAIN
SUPPLY
PIPING
ESCUTCHEON RETAINER
PIPE HANGER DETAIL
NONE
PIPE
GENERAL NOTES:
(HANGER DETAIL ONLY)
A ALL HANGERS SHALL BE SPACED IN ACCORDANCE WITH
PIPE MANUFACTURERS REQUIREMENTS.
EXTERNAL PLUG
DROP IN CONCRETE
ANCHOR
EXISTING TO REMAIN SPRINKLER PIPE
NEW PENDENT SPRINKLER HEAD
POINT OF CONNECTION
EXISTING PENDENT SPRINKLER HEAD TO REMAIN
PIPE TURN DOWN
NEW SPRINKLER PIPE
SPRINKLER PIPE TO BE DEMOLISHED
FIRE PROTECTION LEGEND
EXISTING UPRIGHT SPRINKLER HEAD
EXISTING PENDENT SPRINKLER HEAD TO BE REMOVED
HANGER
ROD
HEX NUT
CLEVIS TYPE
HANGER
STRAP
HANGER
HANGER
ROD
HANGER
ROD
CONCRETE STRUCTURE
PIPE
1 OFFICE
1365F
OF
LAB
1101D
OFFICE
1101C
PHARMACY
CLOSET
1101A-A
STORAGE
1101A
TOILET
1101E
OFFICE
1101B
1 1
2 2 2 2 2 2
CORRIDOR
OFFICE
1365F
OFFICE
I.V.
BUFFER
1101K
ANTE
ROOM
1101J
CHEMO
BUFFER
1101L
CLOSET
1101A-A
OFFICE
1101B
1 1
2 2 2 2 2
DLB DLB
A. CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES TO
PREVENT CONFLICT OF SPACE IN ALL NEW WORK AREAS.
B. PER THE LIFE SAFETY CODE, WHEN A REQUIRED AUTOMATIC FIRE
SPRINKLER SYSTEM (SECTION 9.7.6.1) OR AUTOMATIC FIRE ALARM
SYSTEM (SECTION 9.6.1.6) IS OUT OF SERVICE FOR MORE THAN 4 HOURS
IN A 24-HOUR PERIOD, THE AUTHORITY HAVING JURISDICTION MUST BE
NOTIFIED AND THE BUILDING SHALL BE EVACUATED OR A FIRE WATCH
WILL BE POSTED. THE BUILDING SHALL REMAIN OCCUPIED.
CONTRACTOR SHALL PROVIDE THE REQUIRED FIRE WATCH. IN NO CASE
SHALL THE FIRE PROTECTION SYSTEM BE SHUT DOWN DURING OFF
HOURS OF WORKDAY WITHOUT A FIRE WATCH. THE DURATION OF THE
FIRE WATCH WILL BE UNTIL THE AFFECTED SYSTEM IS FULLY
RESTORED. SYSTEM SHALL BE RETURNED TO NORMAL OPERATING
CONDITIONS AT END OF EACH WORKDAY.
DEMOLITION NOTES FOR THIS SHEET ONLY
1. CONTRACTOR SHALL REMOVE EXISTING SPRINKLER HEADS AND
ASSOCIATED PIPING DROPS REQUIRED BY CEILING REMOVAL.
2. CONTRACTOR SHALL REMOVE EXISTING SPRINKLER HEAD CEILING
ESCUTCHEON IN AREA WHERE CEILING IS BEING REMOVED AND
REPLACED FOR HVAC EQUIPMENT AND DUCT WORK.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018Revisions: Date:
440 Martin Luther King Jr. Blvd
Macon, GA 31201
478.743.8415 Fax: 478.743.8239
www.clarknexsen.com
KEY PLAN
N.T.S.
GENERAL NOTES
FLOOR DEMOLITION FIRE PROTECTION PLAN
PHASE 1 PARTIAL FIRST
FLOOR DEMOLITION FIRE PROTECTION PLAN
PHASE 2 PARTIAL FIRST
1 1
3 5
3 5
3 5
PHARMACY
OFFICE
1101B
CLOSET
1101A-A
4 5
4 5
6 6 6 6 6 6
2 2
4 5
CORRIDOR
OFFICE
1101B
CLOSET
1101A-A
OFFICE
OPEN
OFFICE
4 5
4 5
4 5
6 6 6 6 6 6
DLB DLB
FLOOR FIRE PROTECTION PLAN
PHASE 1 PARTIAL FIRST
FLOOR FIRE PROTECTION PLAN
PHASE 2 PARTIAL FIRST
NEW WORK NOTES FOR THIS DRAWING ONLY
1. CONTRACTOR SHALL INSTALL NEW SPRINKLER PIPING DROPS AND
QUICK RESPONSE SPRINKLER HEADS FOR CLEAN ROOM IN
ACCORDANCE WITH NFPA 13. REFER TO RETURN BEND DROP TO
PENDENT SPRINKLER HEAD FOR USP CLEAN ROOM DETAIL ON FIRE
PROTECTION DRAWING F-001.
2. CONTRACTOR SHALL INSTALL NEW SPRINKLER PIPING DROPS AND
QUICK RESPONSE SPRINKLER HEADS FOR STANDARD COVERAGE IN
ACCORDANCE WITH NFPA 13. REFER TO RETURN BEND TO PENDENT
SPRINKLER HEAD DETAIL ON FORE PROTECTION DRAWING F-001.
3. CONTRACTOR SHALL LOCATE SPRINKLER HEADS IN A UNIFORM
PATTERN AND COORDINATE WITH OTHER CEILING EQUIPMENT
4. CONTRACTOR SHALL LOCATE SPRINKLER HEADS IN CENTER OF CEILING
TILE AND COORDINATE WITH OTHER CEILING EQUIPMENT
5. CONTRACTOR SHALL SUPPORT SPRINKLER PIPING IN ACCORDANCE
WITH SEISMIC REQUIREMENTS OF NFPA 13.
6. CONTRACTOR SHALL INSTALL SPRINKLER HEAD CEILING ESCUTCHEON
IN AREA WHERE CEILING WAS REMOVED AND REPLACED FOR
INSTALLATION OF HVAC EQUIPMENT AND DUCT WORK.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018Revisions: Date:
440 Martin Luther King Jr. Blvd
Macon, GA 31201
478.743.8415 Fax: 478.743.8239
www.clarknexsen.com
KEY PLAN
N.T.S.
GENERAL NOTES
A. CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES TO
PREVENT CONFLICT OF SPACE IN ALL NEW WORK AREAS.
B. PER THE LIFE SAFETY CODE, WHEN A REQUIRED AUTOMATIC FIRE
SPRINKLER SYSTEM (SECTION 9.7.6.1) OR AUTOMATIC FIRE ALARM
SYSTEM (SECTION 9.6.1.6) IS OUT OF SERVICE FOR MORE THAN 4 HOURS
IN A 24-HOUR PERIOD, THE AUTHORITY HAVING JURISDICTION MUST BE
NOTIFIED AND THE BUILDING SHALL BE EVACUATED OR A FIRE WATCH
WILL BE POSTED. THE BUILDING SHALL REMAIN OCCUPIED.
CONTRACTOR SHALL PROVIDE THE REQUIRED FIRE WATCH. IN NO CASE
SHALL THE FIRE PROTECTION SYSTEM BE SHUT DOWN DURING OFF
HOURS OF WORKDAY WITHOUT A FIRE WATCH. THE DURATION OF THE
FIRE WATCH WILL BE UNTIL THE AFFECTED SYSTEM IS FULLY
RESTORED. SYSTEM SHALL BE RETURNED TO NORMAL OPERATING
CONDITIONS AT END OF EACH WORKDAY.
| 3 Plumbing.pdf |
| PL101.pdf |
| 7580 PL101 |
| 7580 PL 101 |
| PL102.pdf |
| 7580 PL102 |
| 7580 PL 102 |
| 4 Fire Protection.pdf |
| F-001.pdf |
| 7580 F-001 |
| 7580 F-001 |
| FD101.pdf |
| 7580 FD101 |
| 7580 FD101 |
| FP101.pdf |
| 7580 FP101 |
| 7580 FP 101 |
File details come from the government source that posted it.