36C24719B0004-0001002.pdf
PDF 4 MB Posted
- Solicitation number
- 36C24719B0004
About this file
36C24719B0004 0001 521-17-101 Combined Drawings_Part2 02.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24719B0004-0004000.docx | DOCX document | |
| 36C24719B0004-0003000.docx | DOCX document | |
| 36C24719B0004-0002002.pdf | ||
| 36C24719B0004-0002003.pdf | ||
| 36C24719B0004-0002001.pdf | ||
| 36C24719B0004-0002000.docx | DOCX document | |
| 36C24719B0004-0001001.pdf | ||
| 36C24719B0004-0001003.pdf | ||
| 36C24719B0004-0001000.docx | DOCX document | |
| 36C24719B0004-000.docx | DOCX document | |
| 36C24719B0004.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPLIED ENGINEERING
SOLUTIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018 PJC JSW
PHASE 1 - PARTIAL FLOOR PLANS FOR PIPE AND
DUCT RISERS - MECHANICAL
M102
KEY PLAN
N.T.S.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018 PJC JSW
PHASE 2 - FIRST FLOOR DUCTWORK AND PIPING
NEW WORK PLANS - MECHANICAL
M103
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018 PJC JSW
PARTIAL FIRST FLOOR AIR FLOW REQUIREMENTS
AND SENSOR/ DISPLAY PANEL LOCATION PLANS -
MECHANICAL
M104
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018 PJC JSW
MECHANICAL DETAILS
M501
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018 PJC JSW
M502
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018 PJC JSW
M503
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018 PJC JSW
M504
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018 PJC JSW
MECHANICAL SCHEDULES
M601
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018 PJC JSW
CONTROL SCHEMATIC, CONTROL SCHEDULES
AND LEGEND - MECHANICAL
M801
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018 PJC JSW
SEQUENCE OF CONTROLS - MECHANICAL
M802
A. THESE DRAWINGS ARE DIAGRAMMATIC ONLY AND ARE NOT TO BE
SCALED. FIELD VERIFY ALL DIMENSIONS, PIPE SIZES, AND INVERTS.
REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND
LOCATIONS OF ALL PLUMBING FIXTURES AND EQUIPMENT.
B. COORDINATE PIPE ROUTING WITH DUCT ROUTING, EQUIPMENT
LOCATIONS, ELECTRICAL INSTALLATIONS, AND BUILDING STRUCTURAL
MEMBERS. OFFSET PIPING WHERE REQUIRED TO AVOID CONFLICTS.
AVOID PENETRATING ANY MAIN STRUCTURAL BEAM. NOTIFY COR OF ANY
CONFLICTS.
C. CONTRACTOR SHALL REMOVE AND REPAIR PORTIONS OF FLOORS,
CEILINGS AND/OR SLABS AFFECTED BY PLUMBING MODIFICATIONS.
REPAIR SURFACES TO MATCH EXISTING UNLESS OTHERWISE NOTED ON
ARCHITECTURAL DRAWINGS.
D. WHERE CHASES ARE NOT PRESENT, CONNECT VENT PIPING TOGETHER
IN CEILING SPACE IF POSSIBLE TO AVOID CUTTING THROUGH STUDS.
E. PRIOR TO PERFORMING ANY PLUMBING WORK OR PURCHASING ANY
MATERIALS VERIFY EXACT LOCATION, ROUTING, AND PIPE SIZES, ETC.
OF ALL EXISTING WASTE, DRAIN, VENT, DOMESTIC WATER SUPPLY AND
RETURN PIPING.
F. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING
CODE, LOCAL CODE, BOTTOM OF STACKS, AND WHERE HORIZONTAL
SANITARY SEWER PIPING CHANGES DIRECTION OVER 45°.
G. NEW 2" SANITARY SEWER PIPING SHALL BE SLOPED A MINIMUM OF TWO
PERCENT, ONE-QUARTER INCH PER FOOT. NEW 3" AND 4" SANITARY
SEWER PIPING SHALL BE SLOPED A MINIMUM OF ONE PERCENT,
ONE-EIGHTH INCH PER FOOT.
H. ALL HORIZONTAL STORM DRAINAGE PIPING SHALL BE INSULATED.
I. ALL DOMESTIC COLD WATER SUPPLY, DOMESTIC HOT WATER SUPPLY,
AND DOMESTIC HOT WATER RETURN PIPING SHALL BE INSULATED
ABOVE CEILING, EXPOSED, IN WALLS AND IN PIPE CHASES.
PLUMBING PIPING SYMBOLS
PIPE, DEMOLITION TO BE REMOVED
FIXTURE OR EQUIPMENT, DEMOLITION TO BE
REMOVED
DOMESTIC COLD WATER, COLD WATER
DOMESTIC HOT WATER, HOT WATER
DOMESTIC HOT WATER RETURN, HOT WATER
RETURN
VENT, SANITARY
SOIL, WASTE, OR SANITARY SEWER
SANITARY SEWER, BELOW FLOOR
STORM WATER DRAINAGESD
PLUMBING ABBREVIATIONS
A/E ARCHITECT / ENGINEER
AC ABOVE CEILING
AFF ABOVE FINISH FLOOR
AG AIR GAP
AP ACCESS PANEL
ASHRAE AMERICAN SOCIETY OF
HEATING, REFRIGERATION,
AIR CONDITIONING
ENGINEERS
ASME AMERICAN SOCIETY OF
MECHANICAL ENGINEERS
ASPE AMERICAN SOCIETY OF
PLUMBING ENGINEERS
BF BELOW FLOOR
BG BELOW GRADE
CFM CUBIC FEET PER MINUTE
DCWS DOMESTIC COLD WATER
DFU DRAINAGE FIXTURE UNITS
DHWR DOMESTIC HOT WATER
RETURN
DHWS DOMESTIC HOT WATER
SUPPLY
DN DOWN
DWG DRAWING
F FAHRENHEIT
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FU FIXTURE UNITS
GAL GALLON
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
H&CW HOT AND COLD WATER
HB HOSE BIBB
HD HUB DRAIN
HP HORSEPOWER
HYD HYDRANT
IPC INTERNATIONAL PLUMBING
CODE
KW KILOWATT
KWH KILOWATT-HOUR
MA MEDICAL AIR
MBH 1000 BTUH
MED MEDICAL
MV MEDICAL VACUUM
NC NORMALLY CLOSED
NTS NOT TO SCALE
OX OXYGEN
PG PRESSURE GAGE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH
ATMOSPHERE
PSIG POUNDS PER SQUARE INCH
GAGE
RP RECIRCULATION PUMP
SS SANITARY SEWER
SCFM STANDARD CUBIC
FOOT/MINUTE
TYP TYPICAL
V VENT
VS VENT STACK
VTR VENT THROUGH ROOF
W WASTE
WCO WALL CLEANOUT
WH WALL HYDRANT
WHA WATER HAMMER ARRESTER
WSFU WATER SUPPLY FIXTURE
UNITS
PLUMBING VALVE SYMBOLS
CHECK VALVE
ANGLE GLOBE VALVE
BALL VALVE
TEST PLUG (PRESSURE/TEMPERATURE)
BALANCING VALVE
VALVE ON RISER
GENERAL PLUMBING SYMBOLS
DIRECTION OF FLOW
REDUCER OR INCREASER
TOP CONNECTION, 45° OR 90°
BOTTOM CONNECTION, 45° OR 90°
SIDE CONNECTION
WATER HAMMER ARRESTOR
RISE OR DROP IN PIPE
UNION
PIPE UP
PIPE DOWN
HOSE BIBB
NON-FREEZE WALL HYDRANT
FLOOR DRAIN
SHOWER DRAIN
HUB DRAIN
PLUGGED TEE
WALL CLEANOUT
POINT OF CONNECTION BETWEEN NEW AND
EXISTING WORK
LIMIT OF DEMOLITION
CONTRACTOR GENERAL NOTES
LEGENDPLUMBING FIXTURE SCHEDULE
MARK FIXTURE DFU
DCWS
WSFU
DHWS
WSFU
TOTAL
WSFU
CONNECTION PIPE SIZE
REMARKS
WASTE VENT DCWS DHWS
P-402 LAVATORY 1.00 0.50 0.50 0.70 1.50 1.50 0.50 0.50 1 AND 3
P-708
EMERGENCY EYE &
FACE WASH
- - - - - - - - 2 AND 3
NOTES:
1. DESIGN BASIS: POWERS LFG480 OR APPROVED EQUAL.
2. EXPOSED, ROUGH BRONZE CHROME PLATED FINISH, SIDE CONNECTIONS, TOP OUTLET.
3. MINIMUM FLOW SHALL BE 0.25 GPM.
DOMESTIC WATER CALCULATIONS
SIZE
GPM
FLUSH VALVE
WSFU
FLUSH TANK
WSFUFLUSH
VALVE
FLUSH
TANK
1/2" 2 2 - 0.25
3/4" 3 3 - 1
NOTES:
1. FIXTURE UNIT VALUES BASED ON THE INTERNATIONAL PLUMBING CODE SIZING CHARTS.
2. MAX VELOCITY FOR HOT WATER - 5 FT/SECOND, FOR COLD WATER 6 FT/SECOND.
THERMOSTATIC TYPE PRESSURE BALANCE MIXING VALVE SCHEDULE
MARK
PIPING PRESSURE
DROP
PSI
CAPACITY
GPM
TEMPERATURE
REMARKS
INLET OUTLET COLD HOT TEMPERED
MV-1 3/8 3/8 5 0.5 50°F 130°F 110°F 1, 2, AND 3
NOTES:
1. WALL HUNG, VITREOUS CHINA, SINGLE SPOUT WALL MOUNTED ELBOW CONTROL FAUCET WITH
VACUUM BREAKER. PROVIDE ASSE 1070 APPROVED THERMOSTATIC MIXING VALVE UNDER SINK.
2. FACUET MOUNTED, LARGE VISIBLE HANDLE OPERATION, PULL KNOB, AND ANTIMICROBIAL
SPRAYHEADS. BASIS OF DESIGN: MANUFACTURER: GUARDIAN, MODEL: G1100.
3. BARRIER-FREE HEALTHCARE INITIATIVE REQUIREMENTS.
PLUMBING FIXTURE UNIT CALCULATION
MARK FIXTURE QTY
DRAINAGE FU DOMESTIC WATER FU
EACH TOTAL
COLD
WATER
EACH
COLD
WATER
TOTAL
HOT
WATER
EACH
HOT
WATER
TOTAL
WATER
SUPPLY
EACH
WATER
SUPPLY
TOTAL
P-402 LAVATORY 1 1.00 1.00 0.50 0.50 0.50 0.50 0.70 0.70
P-708
EMERGENCY EYE &
FACE WASH
1 - - - - - - - -
1.00 0.50 0.50 0.70
DOMESTIC WATER SUPPLY 0.70 WSFU = 3.00 GPM.
DOMESTIC COLD WATER SUPPLY 0.50 WSFU = 3.00 GPM
DOMESTIC HOT WATER SUPPLY 0.50 WSFU = 3.00 GPM
PIPE SIZE: 2" DRAINAGE 1/2" DCWS ~ 1/2" DHWS
SHOCK ABSORBER SCHEDULE
ABSORBOTRON TYPE NO. 5005 5010 5020 5030 5040 5050
P.D.I. SYMBOL A B C D E F
FIXTURE UNIT RATING 1-11 12-32 33-60 61-113 114-154 155-330
NOTES:
1. J.R. SMITH MANUFACTURING COMPANY NUMBER SHOWN. JOSAM, ZURN, OR APPROVED EQUAL IS
ACCEPTABLE.
P-708 P-402
P-708 P-402
2"
(E)5"
(E)5"
3"
2"
S S
S S
(E)1"
(E)1"
(E)3"
(E)3"
1/2"
ISOMETRIC RISER DIAGRAMS
(DOMESTIC WATER DISTRIBUTION)
(WASTE, DRAIN, AND VENT PIPING)
1/2"
DLB DLB
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018Revisions: Date:
440 Martin Luther King Jr. Blvd
Macon, GA 31201
478.743.8415 Fax: 478.743.8239
www.clarknexsen.com
LAB
1101D
OFFICE
1101C
STORAGE
1101A
OFFICE
1365F
TOILET
1101E
CLOSET
1101A-A
PHARMACY
OFFICE
1101B
ROOF
ELEC
MEC
EL
CORRIDOR
1365F
CLOSET
1101A-A
OFFICE
1101B
I.V.
BUFFER
1101K
ANTE
ROOM
1101J
CHEMO
BUFFER
1101L
DLB DLB
A. ALL EXISTING PLUMBING FIXTURES SERVING FIRST FLOOR TO REMAIN
UNLESS OTHERWISE NOTED.
B. ALL EXISTING PLUMBING PIPING SERVING FIRST FLOOR TO REMAIN
UNLESS OTHERWISE NOTED.
C. DEMOLITION SHALL INCLUDE ALL FITTINGS, PIPE SUPPORTS, AND
HANGERS OF PIPING BEING REMOVED.
D. ABANDONED OR UNUSED PIPING AND/OR STACKS SHALL BE REMOVED.
1. REMOVE AND DISCARD EXISTING WALL HUNG LAVATORY, FAUCET,
SUPPLIES, STOPS, TRAP, AND ALL ASSOCIATED PIPING. WASTE PIPING
SHALL BE PLUGGED IN WALL. DOMESTIC WATER PIPING SHALL BE CUT,
REMOVED, DISCARDED AND CAPPED AT THE MAIN.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018Revisions: Date:
440 Martin Luther King Jr. Blvd
Macon, GA 31201
478.743.8415 Fax: 478.743.8239
www.clarknexsen.com
KEY PLAN
N.T.S.
GENERAL NOTES
# DEMOLITION NOTES FOR THIS DRAWING ONLY
FLOOR PIPING DEMOLITION PLAN
PHASE 1 PARTIAL FIRST
FLOOR PIPING DEMOLITION PLAN
PHASE 2 PARTIAL FIRST
DLB DLB
DEMOLITION PIPING PLAN
PARTIAL SECOND FLOOR
DEMOLITION PIPING PLAN
PARTIAL SECOND FLOOR ROOF
A. CONTRACTOR SHALL REMOVE AND REPAIR PORTIONS OF FLOORS,
CEILINGS AND/OR SLABS AFFECTED BY PLUMBING MODIFICATIONS.
REPAIR SURFACES TO MATCH EXISTING UNLESS NOTED OTHERWISE
ON ARCHITECTURAL DRAWINGS.
B. CONTRACTOR SHALL INSPECT AND ROD OUT EXISTING SANITARY
WASTE AND/OR SEWER PIPING BEFORE MAKING ANY NEW
CONNECTIONS. CONTRACTOR SHALL NOTIFY COR OF ALL SANITARY
SEWER WHICH IS NOT SERVICEABLE AND REQUIRE REPLACEMENT.
C. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING
CODE, LOCAL CODE, AND/OR WHERE HORIZONTAL SANITARY SEWER
PIPING CHANGES DIRECTION OVER 45°. NO CLEANOUT(S) WILL BE
ALLOWED ABOVE CEILING UNLESS NOTED OTHERWISE.
D. NEW 2" SANITARY SEWER PIPING SHALL BE SLOPED A MINIMUM TWO
PERCENT, ONE-QUARTER INCH PER FOOT. NEW 3" AND 4" SANITARY
SEWER PIPING SHALL BE SLOPED A MINIMUM ONE PERCENT,
ONE-EIGHTH INCH PER FOOT.
DEMOLITION NOTES FOR THIS DRAWING ONLY
1. EXISTING ROOF DRAIN TO REMAIN.
2. EXISTING VENT THRU ROOF TO REMAIN.
3. CUT, REMOVE, AND DISCARD EXISTING VENT PIPING ABOVE SECOND
FLOOR CEILING AT APPROXIMATE LOCATION INDICATED.
4. CUT, REMOVE, AND DISCARD EXISTING STORM DRAINAGE PIPING
ABOVE SECOND FLOOR AT APPROXIMATE LOCATION INDICATED.
5. PLUG/CAP EXISTING VENT THRU ROOF. AT APPROXIMATE LOCATION
INDICATED.
6. REMOVE AND DISCARD EXISTING ROOF DRAIN. ROOF SHALL BE
REPAIRED TO MATCH EXISTING. REFER TO ARCHITECTURAL
DRAWINGS FOR ADDITIONAL INFORMATION.
7. CUT AND PLUG/CAP EXISTING VENT PIPING BELOW ROOF. REMOVE
AND DISCARD PIPE, FITTINGS, HANGARS AND SUPPORTS ABOVE
SECOND FLOOR CEILING BACK TO LIMITS OF DEMOLITION.
8. REMOVE AND DISCARD EXISTING ROOF LEADER AND STORM
DRAINAGE PIPING BACK TO LIMITS OF DEMOLITION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE SPACE FOR
RELOCATION OF
INPATIENT PHARMACY
BIRMINGHAM VA MEDICAL CENTER
521-17-101
Project Director
08-31-2018Revisions: Date:
440 Martin Luther King Jr. Blvd
Macon, GA 31201
478.743.8415 Fax: 478.743.8239
www.clarknexsen.com
KEY PLAN
N.T.S.
GENERAL NOTES
| 3 Plumbing.pdf |
| P-001.pdf |
| 7580 P-001 |
| 7580 P-001 |
| PD101.pdf |
| 7580 PD101 |
| 7580 PD101 |
| PD102.pdf |
| 7580 PD102 |
| 7580 PD 102 |
File details come from the government source that posted it.