36C24625Q0499.docx

DOCX document 25 KB Posted

Attached to
6515--Sources Sought Endoscope leak tester/maint unit Federal contract opportunity
Solicitation number
36C24625Q0499
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

This Sources Sought notice from the Department of Veterans Affairs Network Contracting Office 6 seeks market research for an Automated Endoscope leak tester and Endoscope Maintenance Unit for the Wake County VA outpatient clinic in Garner, NC. The required equipment includes a dual-scope capable automated leak tester with LCD display, RFID reader, data export capabilities, and approximate dimensions of 11"W x 7.2"D x 7.9"H, along with accessories including wall mount, printer, and scope ID tags. The maintenance unit must be compatible with OES fiberscopes and EVIS EXERA videoscopes, perform alcohol flushing and leakage testing, and measure approximately 3.5"W x 6.5"D x 6"H.

Responses are due by March 10, 2025, at 10AM EST to Byron.Brown4@va.gov. Respondents must indicate if they are small business manufacturers or resellers, provide capability statements, and include manufacturer authorization letters if acting as distributors. The NAICS code is 334510 and PSC is 6515. No set-aside has been specified. This market research will inform the government's acquisition strategy, and no questions will be entertained during this phase.

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
Sources Sought Endoscope leak tester/maint unit

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
23667
SOLICITATION NUMBER*
36C24625Q0499
RESPONSE DATE/TIME/ZONE
03-10-2025 10AM EASTERN TIME, NEW YORK, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
334510

CONTRACTING OFFICE ADDRESS

Department of Veterans Affairs Network Contracting Office 6 100 Emancipation Drive Hampton VA 23667

POINT OF CONTACT*

Contracting Officer Byron Brown Byron.Brown4@va.gov None

PLACE OF PERFORMANCE

ADDRESS
Wake County VA outpatient clinic

Garner NC

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of Garner CBOC is conducting Market Research through this sources sought notice to help determine the availability of qualified Businesses, capable of providing Automated Endoscope leak tester along with Endoscope Maintenance Unit, that meets, but not limited to, the following:

Automated endoscope leak tester

· Dual scope leak test capable

· Performs dry endoscope leak test

· LCD displays workflow instructions, test results and settings

· Electronically export records to a PC for backup and analysis

· Dual automatic and manual leak testing modes

· Self-check on start-up

· Built in RFID reader and data archive capability

· Desktop or wall-mount capability

· Leakage test time approximately three minutes

· Must Include: Wall mount, Printer, Interface cable, Portable memory USB, Scope ID Tags

· Approximate overall size: 11”W x 7.2”D x 7.9”H

Endoscope Maintenance Unit

· Compatible with all OES fiberscopes and EVIS EXERA videoscopes.

· Alcohol flushing of the air/water channel (compatible with OES fiberscopes and 100/130/200/230 series scopes).

· Can help detect hidden pinholes and loose joints preventing fluid invasion

· Performs leakage testing and fluid removal of the air/water channel

· Must Include: Wall mount bracket

· Approximate overall size: 3.5”W x 6.5”D x 6”H

All respondents shall indicate/provide the following:

· Whether or not they are small business manufacturers of the products they wish to offer, or if they are a reseller of a small business manufacturer.

· A copy of its capabilities statement.

Failure to provide the above information may result in the potential offeror being considered incapable of meeting the VA’s needs.

If the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered “grey market” and shall not be considered capable of meeting the VA’s needs.

The capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research, and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses shall be submitted in writing no later then March 10,2025, at 10AM EST to the attention of: Byron.Brown4@va.gov

Please title the subject line for all responses as: Endoscope units