This is a Presolicitation Notice from the Department of Veterans Affairs Network Contracting Office for an endoscope equipment procurement. The solicitation (36C24625Q0499) seeks two specific medical devices: the Olympus America Inc. ALT-Pro Automatic Endoscope Leak Tester (U6008) and the Olympus America Inc. MU-1 Endoscope Maintenance Unit (U6009). The ALT-Pro is a dual-scope leak testing device with features including LCD workflow display, electronic record export, RFID reader, and wall-mount capability, while the MU-1 is compatible with various endoscope types and performs leakage testing and fluid removal.
The solicitation is set for response on 03-24-2025 at 10am Eastern Time, with a product service code of 6515 and NAICS code 334510. The procurement is for two units of each device, which must include specific accessories like wall mounts, printers, and interface cables. The contracting point of contact is Byron Brown (Byron.Brown4@va.gov) at the Department of Veterans Affairs Network Contracting Office located in Hampton, VA 23667. The solicitation will remain in the archive for 30 days after the response date.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Presolicitation Notice Presolicitation Notice
| SUBJECT* |
| Endoscope Leak Tester and Endoscope Maintenance unit with supplies |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 23667 |
| SOLICITATION NUMBER* |
| 36C24625Q0499 |
| RESPONSE DATE/TIME/ZONE |
| 03-24-2025 10am EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 334510 |
PLACE OF PERFORMANCE
POSTAL CODE
COUNTRY
CONTACT INFORMATION
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs Network Contracting Office 6 100 Emancipation Drive Hampton VA 23667
POINT OF CONTACT*
Contracting Officer Byron Brown Byron.Brown4@va.gov None
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
U6008 Automatic Endoscope Leak Tester – Olympus America Inc. ALT-Pro
· Automated endoscope leak tester
· Dual scope leak test capable
· Performs dry endoscope leak test
· LCD displays workflow instructions, test results and settings
· Electronically export records to a PC for backup and analysis
· Dual automatic and manual leak testing modes
· Self-check on start-up
· Built in RFID reader and data archive capability
· Desktop or wall-mount capability
· Leakage test time approximately three minutes
· Must Include: Wall mount, Printer, Interface cable, Portable memory USB, Scope ID Tags
· Approximate overall size: 11”W x 7.2”D x 7.9”H
· Quantity 2 U6009 Endoscope Maintenance Unit – Olympus America Inc. MU-1
· Endoscope Maintenance Unit
· Compatible with all OES fiberscopes and EVIS EXERA videoscopes.
· Alcohol flushing of the air/water channel (compatible with OES fiberscopes and 100/130/200/230 series scopes).
· Can help detect hidden pinholes and loose joints preventing fluid invasion
· Performs leakage testing and fluid removal of the air/water channel
· Must Include: Wall mount bracket
· Power Supply Voltage: 120 V
· Approximate overall size: 3.5”W x 6.5”D x 6”H
· Quantity 2