A600-ED101.pdf
PDF 18 MB Posted
- Attached to
- Z2DZ--Renovate And Replace Pharmacy AHUs Federal contract opportunity
- Solicitation number
- 36C24620R0152
About this file
This document provides details of a federal contract opportunity for renovation work at the Durham VA Medical Center in North Carolina. The Department of Veterans Affairs is seeking a contractor to renovate the main and satellite compounding pharmacies at the medical center, including replacing two air handling units. The work is to be completed in two phases with an estimated value between $1 million and $5 million. It is anticipated to be a set-aside for service-disabled veteran-owned small businesses. The solicitation will be issued on September 29th with proposals due approximately 30 days later. A site visit is scheduled for October 5th. Interested parties should register on the website and check for any amendments, with the point of contact being Desiree Mills-Hicks.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Design Narratives-Final.pdf | ||
| SOW.pdf | ||
| ED102-T602.pdf | ||
| A000-A500.pdf | ||
| 36C24620R0152_2.docx | DOCX document | |
| Specifications-Final.pdf | ||
| 36C24620R0152_1.docx | DOCX document | |
| 36C24620R0152.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL FINISH:
PTM: PATCH TO MATCH EXISTING FINISH.
CT: CERAMIC TILE
FLOORING FINISH:
RF: RUBBER FLOORING.
RF: INTEGRAL BASE - 4".
RB: RESILIANT BASE - 4".
CPT: CARPET.
WALL FINISH:
P: PAINT
RES-W2: SPECIAL COATING - HIGH BUILD GLAZED EPOXY
COATING.
CEILING FINISH:
AT: ACOUSTICAL CEILING TILE.
GWB: GYPSUM WALL BOARD.
NOTE: GC TO PROVIDE SAMPLES FOR ALL FINAL COLOR
SELECTIONS & APPROVAL
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management
558-17-233
Durham VAMC Durham NC
REPLACE PHARMACY AHUS
RENOVATE F1204 & N1004
COMPOUNDING PHARMACIES
102 THIRD AVENUE NORTHEAST
HICKORY, NORTH CAROLINA 28601
PHONE: 828.315.9962
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
NC License No: C‐2848 AME Project No: 18104
VA FORM 08-6231
F
E
D
C
B
A
PLAN NORTH TRUE NORTH A600
DesignerChecker
FINISH INFORMATION
FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY
June 30, 2020 June 30, 2020
WALL & DOOR PROTECTION SCHEDULE
TAG DESCRIPTION COMMENTS
CG-1 CORNER GUARD STAINLESS STEEL
CG-2 CORNER GUARD STAINLESS STEEL
RWC RIGID VINYL WALL COVERING 8' HIGH SHEET
RWC1 RIGID VINYL WALL COVERING 42" HIGH SHEET
FINISH LEGEND
FLOORING FINISH SCHEDULE
ROOM BASE FINISH
LEVEL NUMBER NAME
FLOORING
CODE FLOORING TYPE FLOORING PATTERN FLOORING COLOR FLOORING SIZE ACCENT BASE CODE BASE TYPE BASE STYLE BASE COLOR
LEVEL 01 F1204 PHARMACY PTM PTM PTM PTM PTM PTM PTM PTM PTM PTM
LEVEL 01 F1204D OMNICELL/795 AREA RF Mannington Smooth Welded Rubber Sheet Flooring N/A Light Beige/Gray Taupe Continuous N/A RF Integral Flash Cove Base with Aluminum Extrusion top cap edge Match Flooring Color LEVEL 01 F1204J HAZARDOUS STORAGE RF Mannington Smooth Welded Rubber Sheet Flooring N/A Light Beige/Gray Taupe Continuous N/A RF Integral Flash Cove Base with Aluminum Extrusion top cap edge Match Flooring Color LEVEL 01 F1204K ANTE ROOM RF Mannington Smooth Welded Rubber Sheet Flooring SOLID W/ ACCENT AT DOOR Medium Grey/Taupe Continuous LIGHT GREY/TAUPE RF Integral Flash Cove Base with Aluminum Extrusion top cap edge Match Flooring Color LEVEL 01 F1204L HAZARDOUS COMPOUNDING RF Mannington Smooth Welded Rubber Sheet Flooring SOLID W/ ACCENT AT DOOR Light Beige/Gray Taupe Continuous MEDIUM GREY/TAUPE RF Integral Flash Cove Base with Aluminum Extrusion top cap edge Match Flooring Color LEVEL 01 F1204M NON HAZARDOUS COMPOUNDING RF Mannington Smooth Welded Rubber Sheet Flooring N/A Light Beige/Gray Taupe Continuous N/A RF Integral Flash Cove Base with Aluminum Extrusion top cap edge Match Flooring Color LEVEL 01 F1204N STERILE STORAGE RF Mannington Smooth Welded Rubber Sheet Flooring N/A Light Beige/Gray Taupe Continuous N/A RF Integral Flash Cove Base with Aluminum Extrusion top cap edge Match Flooring Color
LEVEL 01 F1217 LOCKER/BREAK ROOM PTM PTM PTM PTM PTM PTM PTM PTM PTM PTM
LEVEL 01 F1217B SHARED OFFICE CPT Armstrong MedIntone Homogeneous Sheet Flooring TBD Light Beige/Gray Taupe Continuous N/A RB Applied Resiliant Base TBD LEVEL 01 F1217C OFFICE CPT Armstrong MedIntone Homogeneous Sheet Flooring TBD Light Beige/Gray Taupe Continuous N/A RB Applied Resiliant Base TBD
LEVEL 01 N1002 CHEMOTHERAPY PTM PTM PTM PTM PTM PTM PTM PTM PTM PTM
LEVEL 01 N1002B WORK AREA PTM PTM PTM PTM PTM PTM PTM PTM PTM PTM
LEVEL 01 N1004 VESTIBULE RF Mannington Smooth Welded Rubber Sheet Flooring N/A Medium Grey/Taupe Continuous N/A RF Integral Flash Cove Base with Aluminum Extrusion top cap edge Match Flooring Color LEVEL 01 N1004A ANTE ROOM RF Mannington Smooth Welded Rubber Sheet Flooring SOLID W/ ACCENT AT DOOR Light Beige/Gray Taupe Continuous MEDIUM GREY/TAUPE RF Integral Flash Cove Base with Aluminum Extrusion top cap edge Match Flooring Color LEVEL 01 N1004B HAZARDOUS DRUG STORAGE RF Mannington Smooth Welded Rubber Sheet Flooring N/A Light Beige/Gray Taupe Continuous N/A RF Integral Flash Cove Base with Aluminum Extrusion top cap edge Match Flooring Color LEVEL 01 N1004C HAZARDOUS COMPOUNDING RF Mannington Smooth Welded Rubber Sheet Flooring SOLID W/ ACCENT AT DOOR Light Beige/Gray Taupe Continuous MEDIUM GREY/TAUPE RF Integral Flash Cove Base with Aluminum Extrusion top cap edge Match Flooring Color
LEVEL 01 N1006 PHYSICAL THERAPY ROOM PTM PTM PTM PTM PTM PTM PTM PTM PTM PTM
LEVEL 01 N1006A STORAGE PTM Mannington Smooth Welded Rubber Sheet Flooring N/A Light Beige/Gray Taupe Continuous N/A PTM Integral Flash Cove Base with Aluminum Extrusion top cap edge Match Flooring Color LEVEL 01 N1006B VESTIBULE PTM Mannington Smooth Welded Rubber Sheet Flooring N/A Medium Grey/Taupe Continuous N/A PTM Integral Flash Cove Base with Aluminum Extrusion top cap edge Match Flooring Color
LEVEL 01 N1008B MECHANICAL PTM PTM PTM PTM PTM PTM PTM PTM PTM PTM
WALL FINISH SCHEDULE
ROOM WALL FINISH
LEVEL NUMBER NAME
WALL FINISH
CODE WALL FINISH TYPE WALL FINISH COLOR SIZE / COMMENTS
LEVEL 01 F1217 LOCKER/BREAK ROOM PTM Paint to match existing Paint to match existing N/A LEVEL 01 F1204J HAZARDOUS STORAGE RES-W2 Paint Glazed Finish Off White Finish - Submit for approval Similar to PPG Parchment Paper or Sherwin Williams Navajo White LEVEL 01 F1217C OFFICE P Paint Eggshell Finish PPG Parchment Paper - PPG # 1095-1 LEVEL 01 F1204M NON HAZARDOUS COMPOUNDING RES-W2 Paint Glazed Finish Off White Finish - Submit for approval Similar to PPG Parchment Paper or Sherwin Williams Navajo White LEVEL 01 F1204N STERILE STORAGE RES-W2 Paint Glazed Finish Off White Finish - Submit for approval Similar to PPG Parchment Paper or Sherwin Williams Navajo White LEVEL 01 F1204K ANTE ROOM RES-W2 Paint Glazed Finish Off White Finish - Submit for approval Similar to PPG Parchment Paper or Sherwin Williams Navajo White LEVEL 01 F1204L HAZARDOUS COMPOUNDING RES-W2 Paint Glazed Finish Off White Finish - Submit for approval Similar to PPG Parchment Paper or Sherwin Williams Navajo White LEVEL 01 F1204D OMNICELL/795 AREA RES-W2 Paint Glazed Finish Off White Finish - Submit for approval Similar to PPG Parchment Paper or Sherwin Williams Navajo White LEVEL 01 N1004C HAZARDOUS COMPOUNDING RES-W2 Paint Glazed Finish Off White Finish - Submit for approval Similar to PPG Parchment Paper or Sherwin Williams Navajo White LEVEL 01 N1004A ANTE ROOM RES-W2 Paint Glazed Finish Off White Finish - Submit for approval Similar to PPG Parchment Paper or Sherwin Williams Navajo White LEVEL 01 F1217B SHARED OFFICE P Paint Eggshell Finish PPG Parchment Paper - PPG # 1095-1 N/A LEVEL 01 N1004 VESTIBULE RES-W2 Paint Glazed Finish Off White Finish - Submit for approval Similar to PPG Parchment Paper or Sherwin Williams Navajo White LEVEL 01 N1006B VESTIBULE PTM Paint to match existing Paint to match existing N/A LEVEL 01 N1006A STORAGE P Paint Eggshell Finish PPG Parchment Paper - PPG # 1095-1 N/A LEVEL 01 N1004B HAZARDOUS DRUG STORAGE RES-W2 Paint Glazed Finish Off White Finish - Submit for approval Similar to PPG Parchment Paper or Sherwin Williams Navajo White LEVEL 01 N1002B WORK AREA PTM Paint to match existing Paint to match existing N/A LEVEL 01 N1006 PHYSICAL THERAPY ROOM PTM Paint to match existing Paint to match existing N/A LEVEL 01 N1002 CHEMOTHERAPY PTM Paint to match existing Paint to match existing N/A LEVEL 01 F1204 PHARMACY PTM Paint to match existing Paint to match existing N/A LEVEL 01 N1008B MECHANICAL PTM Paint to match existing Paint to match existing N/A
CEILING FINISH SCHEDULE
ROOM GENERAL CEILING FINISH
LEVEL NUMBER NAME CEILING CODE CEILING TYPE CEILING STYLE CEILING COLOR / GRID COLOR CEILING SIZE
LEVEL 01 F1204 PHARMACY PTM PTM PTM PTM PTM
LEVEL 01 F1204D OMNICELL/795 AREA AT-1 ACT Armstrong Unperforated VL Tile White 2' X 2' LEVEL 01 F1204J HAZARDOUS STORAGE GWB RES-W2 Paint Glazed Finish White N/A LEVEL 01 F1204K ANTE ROOM GWB RES-W2 Paint Glazed Finish White N/A LEVEL 01 F1204L HAZARDOUS COMPOUNDING GWB RES-W2 Paint Glazed Finish White N/A LEVEL 01 F1204M NON HAZARDOUS COMPOUNDING GWB RES-W2 Paint Glazed Finish White N/A LEVEL 01 F1204N STERILE STORAGE GWB RES-W2 Paint Glazed Finish White N/A
LEVEL 01 F1217 LOCKER/BREAK ROOM PTM PTM PTM PTM PTM
LEVEL 01 F1217B SHARED OFFICE AT-1 ACT Armstrong Unperforated VL Tile White 2' X 2' LEVEL 01 F1217C OFFICE AT-1 ACT Armstrong Unperforated VL Tile White 2' X 2'
LEVEL 01 N1002 CHEMOTHERAPY PTM PTM PTM PTM PTM
LEVEL 01 N1002B WORK AREA PTM PTM PTM PTM PTM
LEVEL 01 N1004 VESTIBULE AT-1 ACT Armstrong Unperforated VL Tile White 2' X 2' LEVEL 01 N1004A ANTE ROOM GWB RES-W2 Paint Glazed Finish White N/A LEVEL 01 N1004B HAZARDOUS DRUG STORAGE GWB RES-W2 Paint Glazed Finish White N/A LEVEL 01 N1004C HAZARDOUS COMPOUNDING GWB RES-W2 Paint Glazed Finish White N/A
LEVEL 01 N1006 PHYSICAL THERAPY ROOM PTM PTM PTM PTM PTM
LEVEL 01 N1006A STORAGE AT-1 ACT Armstrong Unperforated VL Tile White 2' X 2' LEVEL 01 N1006B VESTIBULE AT-1 ACT Armstrong Unperforated VL Tile White 2' X 2'
LEVEL 01 N1008B MECHANICAL PTM PTM PTM PTM PTM
MILLWORK FINISH SCHEDULE
ROOM MILLWORK CABINET COUNTERTOP
LEVEL NUMBER NAME CABINET CODE CABINET TYPE CABINET MATERIAL
CABINET
COLOR CABINET SIZE/COMMENT
COUNTERTOP
TYPE
COUNTERTOP
MATERIAL
COUNTERTOP
COLOR
LEVEL 01 F1204 PHARMACY MILLWORK N/A N/A N/A COUNTERTOP ONLY Solid Surface Corian - Grade B Savannah LEVEL 01 F1217 LOCKER/BREAK ROOM MILLWORK Plastic Laminate Wilsonart Shaker Cherry # 7935K-07 Silver Wire Pulls Solid Surface Corian - Grade B Savannah LEVEL 01 N1002 CHEMOTHERAPY MILLWORK N/A N/A N/A COUNTERTOP ONLY Solid Surface Corian - Grade B Savannah
ACCEPTABLE MANUFACTURERS
SPECIFIED PRODUCT
LAVATORY
STAINLESS STEEL SINKS
CARRIERS
FAUCETS
CLEANOUTS
VALVES (SAME MANUFACTURER)
INSULATION
WATER SUPPLY BOX
ACCEPTED MANUFACTURERS
AMERICAN STANDARD, CRANE, KOHLER
ELKAY, JUST
JOSAM, SMITH, WADE, ZURN
CHICAGO, KOHLER, SPEAKMAN, T&S BRASS
JOSAM, SMITH, WADE, ZURN, MIFAB
APOLLO, CRANE, ITT GRINELL, NIBCO, MILWAUKEE
ARMSTRONG, CERTAINTEED, KNAUF, JOHNS-MANVILLE
GUY GRAY, SIOUX CHIEF
PLUMBING ABBREVIATIONS
DESCRIPTIONTYPE
ADA AMERICANS WITH DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
BFF BELOW FINISH FLOOR
CI CAST IRON
FF FINISH FLOOR
FT FEET
GAL GALLON
HW HOT WATER
LAV LAVATORY
MAX MAXIMUM
MIN MINIMUM
TYP TYPICAL
WC WATER CLOSET
°F DEGREE FAHRENHEIT
GC GENERAL CONTRACTOR
PC PLUMBING CONTRACTOR
DWV DRAIN, WASTE & VENT
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
ASSE AMERICAN SOCIETY OF SAFETY ENGINEERS
ASTM AMERICAN SOCIETY FOR TESTING & MATERIALS
DIAM DIAMETER
IN INCH
SF SQUARE FEET
VTR VENT THROUGH ROOF
1. ALL PLUMBING VENTS IN EXTERIOR WALLS SHALL BE OFFSET A MINIMUM OF 3'-0"
AT ROOF BEFORE ROOF PENETRATION.
2. ALL PLUMBING VENTS SHALL BE LOCATED NO CLOSER THAN 15'-0" FROM ANY
MECHANICAL UNIT OR OUTDOOR AIR INTAKE. COORDINATE WITH MECHANICAL
CONTRACTOR.
3. ALL PLUMBING AND PLUMBING MATERIALS SHALL MEET THE REQUIREMENTS OF THE
STATE AND LOCAL PLUMBING CODES.
4. THE USE OF HORIZONTAL CLEANOUTS ON SANITARY SEWERS IS PROHIBITED. USE
FLOOR OR WALL CLEANOUT.
5. ALL WALL HYDRANTS SHALL BE MOUNTED 24" ABOVE FINISHED GRADE UNLESS
OTHERWISE SPECIFIED.
6. ALL PIPING SHALL BE ROUTED TO AVOID CONFLICTS WITH OTHER TRADES.
7. COORDINATE WITH ARCHITECTURAL WORKING DRAWINGS BEFORE ROUGHING-IN
PLUMBING FIXTURES.
8. MAKE PROPER HOT AND COLD WATER, WASTE, AND VENT ETC., PIPING
CONNECTIONS TO ALL FIXTURES AND EQUIPMENT EVEN THOUGH ALL BRANCHES,
FITTINGS AND CONNECTIONS MAY NOT BE SHOWN.
9. COORDINATE LOCATION OF ALL EQUIPMENT, FIXTURES AND PIPING WITH
STRUCTURAL AND ALL OTHER TRADES. PIPING ROUTED ABOVE CEILING SHALL BE
ROUTED AS HIGH AS POSSIBLE.
10. ALL OPENINGS IN CEILINGS AND PLENUM WALLS FOR PLUMBING PIPES SHALL BE
SEALED AIR TIGHT.
11. THE USE OF DOUBLE SANITARY "WYE" FITTINGS IS PROHIBITED. USE SINGLE
"WYE" FITTINGS ONLY.
12. ALL HOT AND COLD WATER PIPING INDICATED TO ROUTED ABOVE FINISHED
CEILINGS OR IN EXTERIOR WALLS SHALL BE INSTALLED ON THE CONDITIONED
SPACE SIDE OF THE BUILDING INSULATION.
13. SLOPES AND INVERT ELEVATIONS OF EXISTING SEWERS, ETC., SHALL BE
ESTABLISHED AND VERIFIED BY PLUMBING CONTRACTOR BEFORE ANY PIPING IS
INSTALLED IN ORDER THAT PROPER SLOPES WILL BE MAINTAINED AND NECESSARY
INVERT ELEVATIONS OBTAINED.
14. IT IS THE INTENTION OF THESE DRAWINGS TO COVER ALL WORK AND MATERIAL
FOR A COMPLETE FIRST CLASS INSTALLATION. ANY EQUIPMENT, PLUMBING
FIXTURE, TRIM HARDWARE AND/OR DEVICES USUALLY UTILIZED IN THE CLASS OF
WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS,
BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF THE
WORK (AS DETERMINED BY THE ARCHITECT) SHALL BE FURNISHED AND INSTALLED
BY THE CONTRACTOR AS PART OF HIS TOTAL WORK.
15. VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK OR ORDERING
EQUIPMENT, PIPING, FIXTURES, ETC.
16. SEAL AROUND ALL WALL PENETRATIONS AIR TIGHT AT FIRE RATED WALLS AND FILL
ANY VOIDS APPROVED FIRESTOPPING.
17. INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS AND ALL APPLICABLE LISTING REQUIREMENTS. COORDINATE
BLOCKING AND NECESSARY SUPPORTS WITH THE GENERAL CONTRACTOR. PROVIDE
AND INSTALL UNLESS SPECIFICALLY ASSIGNED BY THE G.C. TO ANOTHER
CONTRACTOR.
18. ANY PIPES PENETRATING RATED WALLS, SMOKE WALLS, SMOKE BARRIERS, ETC.,
SHALL BE SEALED WITH A CODE COMPLIANT U.L. RATED ASSEMBLY THAT
MAINTAINS THE INTEGRITY AND FUNCTION OF THE WALL WHILE ACCOUNTING FOR
THE PIPE MATERIAL, SIZE AND INSULATION.
19. ALL PIPING, FITTINGS, VALVES, ETC. USED IN DOMESTIC WATER SYSTEMS SHALL
BE NSF 61 CERTIFIED.
20. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID TO DETERMINE FIELD
CONDITIONS AND EXTENT OF THE WORK UNDER THIS CONTRACT. LACK O
FKNOWLEDGE OF EXISTING FIELD CONDITIONS WILL NOT BE CONSIDERED A BASIS
FOR CHANGE ORDERS.
PLUMBING GENERAL NOTES
PIPE TURN UP
PIPE TURN DOWN
PIPE DROP OFF BOTTOM OF MAIN PIPE
DOMESTIC COLD WATER PIPE (CW)
DOMESTIC HOT WATER PIPE (HW)
SANITARY WASTE PIPE (S)
SANITARY VENT PIPE (V)
DESIGNATION DESCRIPTION
PLUMBING LEGENDPLUMBING FIXTURE SCHEDULE
NOTES:
1. PROVIDE WITH OFFSET TAILPIECE, CHROME TRAP AND CLEANOUT, AND CHROME SUPPLIES WITH 1/4 TURN STOPS.
2. PROVIDE WITH J-35-SSF DRAIN, JTM-47 THERMOSTATIC MIXING VALVE, JG1800 EYE WASH, AND JMXE-300 EYEWASH MIXING VALVE.
3. PROVIDE WITH ASSE CERTIFIED THERMOSTATIC MIXING VALVE MOUNTED ABOVE CEILING.
FLOOR CLEAN OUT (FCO)/GRADE CLEANOUT (GCO)
FLOOR DRAIN (FD)
FULL PORT BALL VALVE
NEW WORK
DESIGNATION DESCRIPTION
PLUMBING NEW/EXISTING LEGEND
EXISTING TO REMAIN (ETR)
EXISTING TO BE DEMOLISHED (ETBD)
BEGINNING OR END OR NEW WORK OR
CONNECTION TO EXISTING (CTE)
CW COLD WATER
S SANITARY
V VENT
ETBD EXISTING TO BE DEMOLISHED
ETR EXISTING TO REMAIN
CTE CONNECT TO EXISTING
SUSPENDED PIPE ON TRAPEZE
RESTRAIN IF ANY PIPE
ON TRAPEZE >2"
RESTRAIN IF TOTAL
WEIGHT OF PIPES ON
TRAPEZE>10LBS/FT
(SEE NOTE 2)
13.6.8.3.1
REQUIRED
(SEE NOTE 4)
(CAST IRON, PLASTIC, CERAMIC)
(STEEL, AL, CU, ETC.)
RESTRAIN IF>2"
(SEE NOTE 2)
13.6.7
RESTRAIN ALL
PIPE
EQUIPMENT
RESTRAIN IF >75LBS
PROVIDE FLEX CONN.
(SEE NOTE 1)
13.1.4.5
13.6.5
13.1.4.5
13.1.4.5
13.1.4.5RESTRAIN ALL
COMPONENT SUPPORTS
WALL MOUNTED
FLOOR MOUNTED
ROOF MOUNTED
COMPONENT IDENTIFICATION
REQUIREMENT REFERENCE
1.5
COMPONENT IMPORTANCE FACTOR (Ip)
SEISMIC DESIGN CATEGORY C
SEISMIC AND WIND REQUIREMENTS
FOR PLUMBING SYSTEMS
COMPONENT CERTIFICATION
SUSPENDED NON DUCTILE PIPING
SUSPENDED DUCTILE PIPING
NOT INLINE W/
SUSPENDED
SEISMIC RESTRAINT ASCE 7-16
PIPE
INLINE W/
13.2.2
TABLE NOTES:
1. FLEXIBLE CONNECTIONS REQUIRED FOR PIPE CONNECTIONS ONLY.
2. RESTRAINT IS NOT REQUIRED IF THE PIPING IS SUPPORTED BY HANGERS WHERE EACH HANGER IS 12 INCHES OR LESS IN
LENGTH FROM THE TOP OF THE PIPE OR DUCT TO THE SUPPORTING STRUCTURE. WHERE PIPES ARE SUPPORTED ON A TRAPEZE, THE TRAPEZE SHALL BE SUPPORTED BY HANGERS HAVING A LENGTH OF 12 INCHES OR LESS. WHERE ROD
HANGERS ARE USED, THEY SHALL BE EQUIPPED WITH SWIVELS, EYES NUTS OR OTHER DEVICES TO PREVENT BENDING IN
THE ROD.
3. ALL PIPING, REGARDLESS OF SIZE, DESIGNED TO CARRY TOXIC, HIGHLY TOXIC, OR EXPLOSIVE GASES MUST BE
RESTRAINED.
4. COMPONENT CERTIFICATION MUST BE SUPPLIED BY THE EQUIPMENT MANUFACTURER AT THE TIME OF SUBMITTAL FOR
REVIEW BY ENGINEER OF RECORD.
A. PER 2018 INTERNATIONAL BUILDING CODE, MECHANICAL EQUIPMENT AND COMPONENTS, INCLUDING THEIR SUPPORTS AND ATTACHMENTS, SHALL BE DESIGNED FOR SEISMIC FORCES IN ACCORDANCE WITH CHAPTER 13 OF ASCE 7-16.
B. EXTERIOR EQUIPMENT (INCLUDING ROOF CURBS AND ROOF RAILS) EXPOSED TO WIND SHALL BE DESIGNED AND INSTALLED
TO RESIST THE WIND PRESSURES DETERMINED IN ACCORDANCE WITH CHAPTERS 26 THROUGH 29 OF ASCE 7-16.
C. WHERE DESIGN FOR SEISMIC AND WIND LOADS IS REQUIRED, THE MORE DEMANDING FORCE MUST BE USED.
D. REFERENCE THE STRUCTURAL DRAWINGS FOR SITE SPECIFIC INFORMATION ON SEISMIC DESIGN CATEGORY, WIND SPEED, ETC.
E. USE TABLE BELOW TO DETERMINE SEISMIC RESTRAINT REQUIREMENTS FOR EACH COMPONENT.
F. FOR ALL COMPONENTS REQUIRING SEISMIC RESTRAINT, THE COMPONENT SUPPORTS AND ATTACHMENTS SHALL BE
DESIGNED BY A REGISTERED DESIGN PROFESSIONAL.
G. WHERE SEISMIC RESTRAINT IS REQUIRED, HOUSEKEEPING PADS NEEDED FOR THE INSTALLATION OF EQUIPMENT UNDER THIS CONTRACT MUST BE DESIGNED BY THE SEISMIC ENGINEER. DO NOT POUR ANY HOUSEKEEPING PADS PRIOR TO THE
RECEIPT OF APPROVED SEISMIC SUBMITTAL.
H. SEISMIC RESTRAINTS FOR DUCTWORK, PIPING AND CONDUIT MUST BE SHOWN ON SEISMIC SUBMITTAL LAYOUT DRAWINGS SHOWING SPECIFIC RESTRAINT LOCATIONS ALONG WITH ACCOMPANYING DETAILS AND CALCULATIONS.
INFORMATION FOR / IBC-2018 / ASCE 7-16
RISK CATEGORY IV
RESTRAIN ALL
RESTRAIN ALL
RESTRAIN ALL
RESTRAIN IF>2"
(SEE NOTE 2)
13.6.8.3.3.a
13.6.8.3.3
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management
558-17-233
Durham VAMC Durham NC
REPLACE PHARMACY AHUS
RENOVATE F1204 & N1004
COMPOUNDING PHARMACIES
102 THIRD AVENUE NORTHEAST
HICKORY, NORTH CAROLINA 28601
PHONE: 828.315.9962
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
NC License No: C-2848
AME Project No: 18104
VA FORM 08-6231
F
E
D
C
B
A
PLAN NORTH TRUE NORTH
P-001
DBWFFR
PLUMBING - GENERAL NOTES, SCHEDULES
AND LEGENDS
FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY
June 30, 2020
MARK DESCRIPTION
CONNECTION SIZES
MANUFACTURER MODEL TRIM MOUNTING NOTESWASTE VENT CW HW
P-4 PHARMACY WASH UP
SINK
2" 1-1/2" 1/2" 1/2" JUST MFG. JPH-ADA-2224-CT JUST JSL-46-AC WALL 2
P-6 INTEGRAL SINK 2" 1-1/2" 1/2" 1/2" EXISTING TO BE
RELOCATED
- NEW FAUCET: CHICAGO 116.103.AB.1 COUNTER 1
P-8 CONDENSATE DRAIN
BOX
1-1/2" 1-1/2" - - SIOUX CHIEF OX BOX 696 N/A WALL
P-9 EMERGGENCY
EYEWASH
FD - 1" 1" HAWS
CORPORATION
7360BT - FLOOR 3
FCO FLOOR CLEANOUT 2" 1-1/2" - - ZURN ZN1400-IC3 - FLOOR
DEMOLISH EXISTING
SINK COMPLETE
(ETR) (ETR)
(ETR)
(ETR)
EXISTING S RISER
EXISTING V RISER (ETR)4" S
(ETR)2" V
(ETR)
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management
558-17-233
Durham VAMC Durham NC
REPLACE PHARMACY AHUS
RENOVATE F1204 & N1004
COMPOUNDING PHARMACIES
102 THIRD AVENUE NORTHEAST
HICKORY, NORTH CAROLINA 28601
PHONE: 828.315.9962
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
NC License No: C-2848
AME Project No: 18104
VA FORM 08-6231
F
E
D
C
B
A
PLAN NORTH TRUE NORTH
PD101
DBWFFR
PLUMBING - DEMOLITION PLAN - LEVEL 01 -
F1204
FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY
June 30, 2020
1/4" = 1'-0"
PLUMBING - DEMOLITION PLAN - LEVEL 01 - F1204
0' 2' 4' 8'
SCALE: 1/4" = 1'-0"
EXISTING OXYGEN AND
MEDICAL VACUUM OUTLETS
AND ASSOCIATED SLIDE
SHALL BE DEMOLISHED.
ASSOCIATED MEDICAL GAS
PIPING SHALL BE
DEMOLISHED BACK TO MAIN
AND CAPPED. ALL AFFECTED
PIPING SHALL BE
RECERTIFIED AS PER
NFPA-99.
DEMOLISH EXISTING
EMERGENCY SHOWER/
EYEWASH COMPLETE
DEMOLISH
EXISTING WALL
HUNG SINK
COMPLETE.
EXISTING SINK AND CABINET
TO BE RELOCATED. REMOVE
EXISTING FAUCET, TRAP AND
SUPPLIES COMPLETE.
DEMOLISH MOP
SINK COMPLETE.
(ETR) S AND V STACK
(ETR)FCO
2" S(ETR)
S (ETR)
3" S(ETR)
BFF
BFF
BFF BFF
BFFBFF
B F F
B F F
BFF
2 1/2" HW
4" CW
2 1/2" HW
4" CW
(ETR)
(ETR)
(ETR)
(ETR)
1/2" HW
1/2" HW(ETBR)
(ETBR)
1 1/2" V (ETBR)
2" S(ETBR)
1/2" HW
1/2" CW (ETBR)
(ETBR)
1" CW(ETBR)
1" CW
1" HW
(ETR)
(ETR)
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management
558-17-233
Durham VAMC Durham NC
REPLACE PHARMACY AHUS
RENOVATE F1204 & N1004
COMPOUNDING PHARMACIES
102 THIRD AVENUE NORTHEAST
HICKORY, NORTH CAROLINA 28601
PHONE: 828.315.9962
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
NC License No: C-2848
AME Project No: 18104
VA FORM 08-6231
F
E
D
C
B
A
PLAN NORTH TRUE NORTH
PD102
DBWFFR
PLUMBING - DEMOLITION PLAN - LEVEL 01 -
N1004
FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY
June 30, 2020
1/4" = 1'-0"
PLUMBING - DEMOLITION PLAN - LEVEL 01 - N1004
OFFICE
F1217C
SHARED
OFFICE
F1217B
HAZARDOUS
COMPOUNDING
F1204L
HAZARDOUS
STORAGE
F1204J
ANTE
ROOM
F1204K
NON
HAZARDOUS
COMPOUNDING
F1204M
STERILE
STORAGE
F1204N
PHARMACY
F1204
OMNICELL/795
AREA
F1204D
LOCKER/BREAK
ROOM
F1217
(ETR) (ETR)
(ETR)
(ETR)
2" V2" S
P-4
(ETR)4" S
(ETR)2" V
(ETR)4" S
(ETR)2" V
SMOKE TIGHT PARTITION
RATED WALL LEGEND
1 HOUR FIRE BARRIER
2 HOUR FIRE BARRIER
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management
558-17-233
Durham VAMC Durham NC
REPLACE PHARMACY AHUS
RENOVATE F1204 & N1004
COMPOUNDING PHARMACIES
102 THIRD AVENUE NORTHEAST
HICKORY, NORTH CAROLINA 28601
PHONE: 828.315.9962
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
NC License No: C-2848
AME Project No: 18104
VA FORM 08-6231
F
E
D
C
B
A
PLAN NORTH TRUE NORTH
PL101
DBWFFR
PLUMBING - NEW WORK PLAN - LEVEL 01 -
F1204 - WASTE AND VENT PIPING
FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY
June 30, 2020
1/4" = 1'-0"
PLUMBING - NEW WORK PLAN - LEVEL 01 - F1204 - WASTE AND VENT PIPING
STORAGE
N1006A
HAZARDOUS
DRUG
STORAGE
N1004B
HAZARDOUS
COMPOUNDING
N1004C
ANTE
ROOM
N1004A
VESTIBULE
N1004
VESTIBULE
N1006B
PHYSICAL
THERAPY
ROOM
N1006
CHEMOTHERAPY
N1002
WORK
AREA
N1002B
(ETR)FCO
P-6
3" S
2" S
S
3" V
(ETR)
(ETR)
(ETR)
(ETR)
(ETR) S AND V STACK
1 1/2" V
2" S
1 1/2" V
P-4
P-9
1 1/2" V
P-8
SMOKE TIGHT PARTITION
RATED WALL LEGEND
1 HOUR FIRE BARRIER
2 HOUR FIRE BARRIER
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management
558-17-233
Durham VAMC Durham NC
REPLACE PHARMACY AHUS
RENOVATE F1204 & N1004
COMPOUNDING PHARMACIES
102 THIRD AVENUE NORTHEAST
HICKORY, NORTH CAROLINA 28601
PHONE: 828.315.9962
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
NC License No: C-2848
AME Project No: 18104
VA FORM 08-6231
F
E
D
C
B
A
PLAN NORTH TRUE NORTH
PL102
DBWFFR
PLUMBING - NEW WORK PLAN - LEVEL 01 -
N1004 - WASTE AND VENT PIPING
FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY
June 30, 2020
1/4" = 1'-0"
PLUMBING - NEW WORK PLAN - LEVEL 01 - N1004 - WASTE AND VENT PIPING
(ETR) (ETR)
(ETR)
(ETR)
P-4
HAZARDOUS
STORAGE
F1204J
OFFICE
F1217C
NON
HAZARDOUS
COMPOUNDING
F1204M
STERILE
STORAGE
F1204N
ANTE
ROOM
F1204K
HAZARDOUS
COMPOUNDING
F1204L
OMNICELL/795
AREA
F1204D
SHARED
OFFICE
F1217B
PHARMACY
F1204
1/2" HW
1/2" CW
(ETR)CW AND HW RISERS
IN CHASE TO FIXTURES
1/2"CW UP TO AHU-1204 ON
INTERSTITIAL SPACE ABOVE.
PROVIDE BACKFLOW DEVICE
EQUAL TO ZURN/WILKINS
375ST - 1/2". MOUNT ON WALL
ADJACENT TO UNIT. PROVIDE FUNNEL
DRAIN AND INDIRECT WASTE
PIPING TO FLOOR DRAIN FOR AHU.
1/2" CW
1/2" CW
1/2" HW
SMOKE TIGHT PARTITION
RATED WALL LEGEND
1 HOUR FIRE BARRIER
2 HOUR FIRE BARRIER
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management
558-17-233
Durham VAMC Durham NC
REPLACE PHARMACY AHUS
RENOVATE F1204 & N1004
COMPOUNDING PHARMACIES
102 THIRD AVENUE NORTHEAST
HICKORY, NORTH CAROLINA 28601
PHONE: 828.315.9962
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
NC License No: C-2848
AME Project No: 18104
VA FORM 08-6231
F
E
D
C
B
A
PLAN NORTH TRUE NORTH
PL201
DBWFFR
PLUMBING - NEW WORK PLAN - LEVEL 01 -
F1204 - WATER SUPPLY PIPING
FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY
June 30, 2020
1/4" = 1'-0"
PLUMBING - NEW WORK PLAN - LEVEL 01 - F1204 - WATER SUPPLY PIPING
P-6
B F F
B F F
BFF
BFF
B F F
B F F
BFF
BFF BFF
BFF
B F F
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1" HW
1" CW (ETR)
(ETR)
2 1/2" HW
4" CW
(ETR)
(ETR)
B F F
HAZARDOUS
COMPOUNDING
N1004C
ANTE
ROOM
N1004A
VESTIBULE
N1004
VESTIBULE
N1006B
STORAGE
N1006A
HAZARDOUS
DRUG
STORAGE
N1004B
WORK
AREA
N1002B
PHYSICAL
THERAPY
ROOM
N1006
CHEMOTHERAPY
N1002
P-4
BFF
BFF
P-9
B F F
1" CW
1" HW
1/2" CW
1/2"CW UP TO AHU-N1004
ON ROOF. ROUTE CW UP
THROUGH ROOF CURB TO
UNIT. FINAL CONNECTION
BY MECH. CONTRACTOR.
1/2"CW UP
TO ABOVE
CEILING.
BACKFLOW DEVICE EQUAL TO
ZURN/WILKINS 375ST - 1/2"
PROVIDE FUNNEL DRAIN AND
INDIRECT WASTE PIPING TO
DRAIN BOX P-8
SMOKE TIGHT PARTITION
RATED WALL LEGEND
1 HOUR FIRE BARRIER
2 HOUR FIRE BARRIER
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management
558-17-233
Durham VAMC Durham NC
REPLACE PHARMACY AHUS
RENOVATE F1204 & N1004
COMPOUNDING PHARMACIES
102 THIRD AVENUE NORTHEAST
HICKORY, NORTH CAROLINA 28601
PHONE: 828.315.9962
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
NC License No: C-2848
AME Project No: 18104
VA FORM 08-6231
F
E
D
C
B
A
PLAN NORTH TRUE NORTH
PL202
DBWFFR
PLUMBING - NEW WORK PLAN - LEVEL 01 -
N1004 - WATER SUPPLY PIPING
FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY
June 30, 2020
1/4" = 1'-0"
PLUMBING - NEW WORK PLAN - LEVEL 01 - N1004 - WATER SUPPLY PIPING
2" V
2" S
1/2" CW
1/2" HW
P-4
1/2" CW
2" S
2" V
1/2" HW
P-8
1 1/2" V
P-6
1 1/2" V
1/2" CW
1/2" HW
2" S
(ETR)1" CW
(ETR)1" HW
(ETR)4" S
(ETR)4" V
(ETR)4" S
(ETR)3" S
FCO
P-9
2" S
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management
558-17-233
Durham VAMC Durham NC
REPLACE PHARMACY AHUS
RENOVATE F1204 & N1004
COMPOUNDING PHARMACIES
102 THIRD AVENUE NORTHEAST
HICKORY, NORTH CAROLINA 28601
PHONE: 828.315.9962
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
NC License No: C-2848
AME Project No: 18104
VA FORM 08-6231
F
E
D
C
B
A
PLAN NORTH TRUE NORTH
P-501
DBWFFR
PLUMBING - RISERS
FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY
June 30, 2020
NTS
WASTE AND VENT RISER SCHEMATIC -F1204 PHARMACY
NTS
WASTE AND VENT RISER SCHEMATIC - N1004 SATELITE PHARMACY
CLAMP MUST BE LOCATED
MAXIMUM OF 3" FROM
JOIST
PANEL POINT. IF NOT,
PROVIDE
VERTICAL ANGLE IRON
SUPPORT FRONT AND BACK
TO STRENGTHEN.
B-LINE OR EQUAL TOP
BEAM CLAMP. (USE ONLY
ON
LEVEL JOIST MEMBERS)
B-LINE B3100 OR
EQUAL CLEVIS
HANGER.
PIPE INSULATION. REFER
TO SPECIFICATIONS FOR
DETAILS.
PIPING. REFER TO
SPECIFICATIONS
FOR
DETAILS.
B-LINE B3151 OR
EQUAL SHEET METAL
INSULATION SHIELD.
NOTES:
1. PIPE HANGER SPACING SHALL BE IN ACCORDANCE WITH 2018 INTERNATIONAL
BUILDING CODE.
2. PROVIDE UNISTRUT OR ANGLE IRON BRIDGING SPANNING MULTIPLE BAR
JOISTS AS REQUIRED.
3. PRIME OR PAINT ALL HANGERS, PIPE WELDS, AND OTHER ITEMS SUBJECT
TO RUSTING.
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management
558-17-233
Durham VAMC Durham NC
REPLACE PHARMACY AHUS
RENOVATE F1204 & N1004
COMPOUNDING PHARMACIES
102 THIRD AVENUE NORTHEAST
HICKORY, NORTH CAROLINA 28601
PHONE: 828.315.9962
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
NC License No: C-2848
AME Project No: 18104
VA FORM 08-6231
F
E
D
C
B
A
PLAN NORTH TRUE NORTH
P-701
DBWFFR
PLUMBING - DETAILS
FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY
June 30, 2020
NTS
INDIVIDUAL PIPE HANGER METAL FRAMING DETAIL
PIPE TURN UP (UP)
PIPE TURN DOWN (DN)
MECHANICAL PIPING LEGEND
CONDENSATE DRAIN PIPINGCD
HEATING EFFICIENCY: SEE SCHEDULES
COOLING EFFICIENCY: SEE SCHEDULES
MECHANICAL SPACING CONDITIONING SYSTEM
BUILDING COOLING LOAD: EXISTING - NO CHANGE
BUILDING HEATING LOAD: EXISTING - NO CHANGE
EXISTING - NO CHANGE
MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT.
SUMMER WET BULB: 74.0°F
METHOD OF COMPLIANCE: PRESCRIPTIVE
CODE ENFORCEMENT JURISDICTION: VAMC
NAME OF PROJECT: DURHAM VAMC REPLACE PHARMACY AIR
HANDLER UNITS
BUILDING OCCUPANCY: I-2
OWNER/CONTACT PERSON: DEREK GROTHEER
ADDRESS: 508 FULTON STREET DURHAM, NC 27705
EXTERIOR DESIGN CONDITIONS:
WINTER DRY BULB: 17.5°F
SUMMER DRY BULB: 93.2°F
THERMAL ZONE: 4A
GROSS BUILDING AREA:
PROPOSED USE: HOSPITAL
MECHANICAL CODE SUMMARY
RELATIVE HUMIDITY: 50% R.H.
INTERIOR DESIGN CONDITIONS (PHARMACY COMPOUNDING):
WINTER DRY BULB: 64°F
SUMMER DRY BULB: 64°F
DESCRIPTION OF UNIT: MODULAR ROOFTOP & INDOOR AIR
HANDLING UNITS, LAB EXHAUST FANS
COOLING OUTPUT OF SYSTEMS: SEE SCHEDULES
HEAT OUTPUT OF SYSTEMS: SEE SCHEDULES
DESIGNATION DESCRIPTION
EXISTING TO REMAIN
(EQUIPMENT, DUCTWORK, PIPING, ETC.)
EXISTING/DEMO/NEW LEGEND
EXISTING TO BE DEMOlLISHED OR RELOCATED -
REFER TO PLAN NOTES PRIOR TO DEMOLITION
(EQUIPMENT, DUCTWORK, PIPING, ETC.)
NEW
(EQUIPMENT, DUCTWORK, PIPING, ETC.)
BEGINNING OR END OF NEW WORK -OR-
CONNECT TO EXISTING
MECHANICAL GENERAL NOTES
GENERAL ITEMS
1. GENERAL NOTES ON THIS DRAWING ARE APPLICABLE TO EACH HVAC
DRAWING OF THIS SET. SEE EACH DRAWING FOR SPECIFIC NOTES
APPLICABLE TO THAT DRAWING.
2. OVERHEAD PIPING AND DUCTWORK IN SPACES WITHOUT HUNG CEILINGS
SHALL BE RUN AS CLOSE TO ROOF DECK AS PRACTICAL, AS CLOSE TO
PARALLEL JOISTS AS POSSIBLE AND ABOVE LIGHTING FIXTURES TO
CONCEAL PIPING.
3. OVERHEAD DUCTWORK AND PIPING IN SPACES WITH CEILINGS SHALL BE
CONCEALED UNLESS OTHERWISE NOTED.
4. COORDINATE LOCATION OF GRILLES, REGISTERS, DIFFUSERS,
THERMOSTATS AND OTHER WALL OR CEILING MOUNTED HVAC
ACCESSORIES WITH REFLECTED CEILING PLAN, LIGHTING FIXTURE
LAYOUT AND ACCESSORIES INSTALLED BY OTHER TRADES SO AS TO
PRESENT A NEAT AND ATTRACTIVE INSTALLATION THROUGHOUT THE
ENTIRE BUILDING. IT IS THE INTENT FOR GRILLES, REGISTERS AND
DIFFUSERS TO BE INSTALLED IN THE CENTER OF CEILING PANELS.
5. ARRANGE PIPING AND DUCTWORK, PARTICULARLY ABOVE CEILING AS
REQUIRED TO CLEAR STRUCTURE, DUCTS, CONDUITS, ETC. ALLOWING
SPACE FOR PIPE HANGERS, ACCESS TO VALVES, FILTERS, AND
MAINTENANCE OF EQUIPMENT.
6. EQUIPMENT WITH FILTERS SHALL BE INSTALLED SO THAT FILTERS CAN BE
EASILY REMOVED AND REPLACED.
7. COORDINATE LOCATION AND INSTALLATION OF EQUIPMENT WITH OTHER
TRADES.
8. DO NOT SCALE DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR EXACT
LOCATIONS OF DOORS, WINDOWS, ETC.
9. THERMOSTATS SHALL BE LOCATED IN THE ROOMS INDICATED. INSTALL
AT 48" ABOVE FINISH FLOOR.
10. PIPING, DUCTWORK, VENTS, ETC., EXTENDING THROUGH EXTERIOR
WALLS AND ROOF SHALL BE FLASHED AND COUNTER FLASHED IN A
WEATHERPROOF MANNER.
11. PIPING AND DUCTWORK INSULATION SHALL RUN CONTINUOUSLY
THROUGH NON-RATED FLOORS, WALLS, ROOF AND PARTITIONS, UNLESS
OTHERWISE INDICATED.
12. FLEXIBLE AIR DUCTS SHALL HAVE UL 181 LISTING, FIBERGLASS SCRIM,
R-6 INSULATION, AND MAXIMUM DISTANCE OF 6'-0".
13. NO PIPING SHALL BE SMALLER THAN 3/4" UNLESS OTHERWISE NOTED.
14. PROVIDE UNION OR FLANGED CONNECTIONS AT EACH PIECE OF
EQUIPMENT AND ON BOTH SIDES OF CONTROL VALVES AND PRESSURE
REGULATING VALVES. PROVIDE SHUT-OFF VALVES ON BOTH SIDES OF
AUTOMATIC VALVES.
15. PIPING SHALL BE SUPPORTED IN ACCORDANCE WITH THE
SPECIFICATIONS. ADDITIONAL SUPPORTS OR HANGERS SHALL BE
ADJACENT TO ELBOWS TO PREVENT WEIGHT OF PIPING BEING PLACED
ON EQUIPMENT.
16. ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE
WITH THE LATEST EDITION OF SMACNA'S "HVAC DUCT CONSTRUCTION
STANDARDS - METAL AND FLEXIBLE."
17. PROVIDE BEARING PLATES AND OTHER NECESSARY REINFORCEMENT AT
DUCTWORK SUPPORTS TO ENSURE THAT DUCT INSULATION MAINTAINS
REQUIRED "R" VALUES.
18. PROVIDE ACCESS DOORS IN DUCTWORK WHERE INDICATED OR
REQUIRED FOR ACCESS TO SYSTEM COMPONENTS INCLUDING THE
FOLLOWING:
A. DAMPER MOTORS AND/OR MOTOR OPERATED DAMPERS
B. FILTERS
C. FIRE DAMPERS AND SMOKE DAMPERS
D. SMOKE DETECTORS
19. PROVIDE A MINIMUM OF THREE TIMES THE FAN DIAMETER OF STRAIGHT
DUCTWORK OFF THE SUPPLY AIR FAN DISCHARGE BEFORE ANY TAKEOFFS
OR ELBOWS.
20. PROVIDE EXTENDED VOLUME DAMPER CONTROL RODS SO THAT HANDLES
ARE WELL CLEAR OF DUCT INSULATION.
DESIGNATION DESCRIPTION
TEST AND BALANCE NOTE
1. THE CONTRACTOR SHALL HIRE AN APPROVED TEST
AND BALANCE AGENCY TO PERFORM A FULL TEST
AND BALANCE OF THE RENOVATED AREAS AFTER
CONSTRUCTION IS COMPLETE. TEST AND BALANCE
SHALL INCLUDE (BUT NOT LIMITED TO) MODULAR AIR
HANDLING UNITS, EXHAUST FANS, VAV TERMINAL
UNITS, CHILLED WATER COILS, STEAM HEATING
COILS, STEAM HUMIDIFIERS, HEATING HOT WATER
COILS, AND EXISTING EQUIPMENT TO REMAIN.
2. THE CONTRACTOR IS RESPONSIBLE FOR TEST AND
BALANCE OF ALL SYSTEMS WITHIN THE RENOVATED
AREAS (INCLUDING EXISTING TO REMAIN
EQUIPMENT) TO ACHIEVE THE AIRFLOWS AND FLOW
RATES INDICATED ON THESE CONSTRUCTION
DOCUMENTS.
3. THESE DRAWINGS ARE BASED ON EXISTING
DOCUMENTS AND LIMITED FIELD OBSERVATIONS.
THE CONTRACTOR SHALL CONDUCT A TEST OF
EXISTING SYSTEMS PRIOR TO STARTING WORK TO
ESTABLISH AIRFLOWS FOR ALL EXISTING AIR
DISTRIBUTION DEVICES AND TO VERIFY SUFFICIENT
AIRFLOW IS AVAILABLE TO ACHIEVE THE AIRFLOWS
INDICATED ON THESE DRAWINGS. UPON
COMPLETION OF WORK, ALL AIR DISTRIBUTION
DEVICES NOT SPECIFICALLY TAGGED SHALL BE
BALANCED TO THEIR ORIGINAL AIRFLOWS. REPORT
ANY DEFICIENCIES TO THE VA COR AND ENGINEER
PRIOR TO STARTING WORK.
HOT WATER RETURN (HEATING)HWR
HOT WATER SUPPLY (HEATING)HWS
CHILLED WATER RETURNCWR
CHILLED WATER SUPPLYCWS
2-WAY CONTROL VALVE
BUTTERFLY VALVE
UNION
DIRECTION OF FLOW
FULL PORT BALL VALVE
AUTOMATIC FLOW LIMITING VALVE
AF
CHECK VALVE
Y-STRAINER
FS FLOW SWITCH
FM FLOW METER
TS TEMPERATURE SENSOR
PS PRESSURE SENSOR
RELATIVE HUMIDITYRH
RETURN AIRRA
PHASEPH
PRESSURE DROPPD
OUTDOOR AIROA
MINIMUM CIRCUIT AMPACITYMCA
MECHANICAL CONTRACTORM.C.
1000 BTU PER HOURMBH
MAXIMUMMAX
LEAVING AIR TEMPERATURELAT
FAN FILTER UNITFFU
CUBIC FEET PER MINUTECFM
BIOLOGICAL SAFETY CABINETBSC
SUPPLY AIR
NOISE CRITERIA
MAXIMUM OVER CURRENT PROTECTION
INCHES WATER GAUGE (PRESSURE)
FULL LOAD AMPS
SA
NC
MOCP
EXTERNAL STATIC PRESSURE
ALARM
AIR HANDLING UNIT
ABOVE FINISHED FLOOR
IN. WG.
FLA
ESP
AL
AHU
AFF
MECHANICAL ABBREVIATIONS
VARIABLE AIR VOLUMEVAV
SP STATIC PRESSURE
DESCRIPTIONDESIGNATION
ENTERING AIR TEMPERATUREEAT
SENSIBLESENS
EXHAUST FANEF
WET BULB TEMPERATUREWB
DRY BULB TEMPERATUREDB
ENGINEERING CONTROL CENTER (BAS)ECC
CONTROLS CONTRACTORC.C.
DIFFERENTIAL PRESSUREDP
VARIABLE FREQUENCY DRIVEVFD
TSP TOTAL STATIC PRESSURE
UNLESS NOTED OTHERWISEUNO
HORSEPOWERHP
SUPPLY AIR DUCT WITH TURNING VANES
TURNING UP/DOWN
DESIGNATION DESCRIPTION
RETURN AIR DUCT WITH TURNING VANES
TURNING UP/DOWN
MITERED 90 ELBOW WITH TURNING VANES
EXHAUST AIR DUCT WITH TURNING VANES
TURNING UP/DOWN
MECHANICAL SYMBOL LEGEND
DD
MANUAL VOLUME DAMPER WITH EXTENDED
CONTROL ROD
DUCT
CEILING MOUNTED SUPPLY DIFFUSER
CEILING MOUNTED RETURN GRILLE
CEILING MOUNTED EXHAUST GRILLE
T
TEMPERATURE SENSOR. MOUNT 4'-0" A.F.F. PER
THE ACCESSIBILITY CODE.
COMBINATION FIRE/SMOKE DAMPER, WITH 24V
ACTUATOR, VERTICAL, WITH ACCESS DOOR AND
DUCT SMOKE DETECTOR, UL 555 AND UL 555S.
F/S
FIRE DAMPER, VERTICAL, DYNAMIC TYPE WITH
BLADES OUT OF AIRSTREAM, WITH ACCESS DOOR,
UL 555.
FD
SMOKE DAMPER, VERTICAL, WITH ACCESS DOOR
AND DUCT SMOKE DETECTOR, UL 555.
SD
DUCT ACCESS DOOR LOCATION
DUCT SMOKE DETECTOR ASSEMBLY INCLUDING
SAMPLING TUBE AND SHUTDOWN RELAY.
INSTALLATION PER SECTION 907.3.1 OF THE 2018
INTERNATIONAL FIRE CODE
M
MOTORIZED CONTROL DAMPER WITH 24V
ACTUATOR
AD
COMPONENT
CERTIFICATION
ROOF MOUNTED
COMPONENT
IDENTIFICATION
TABLE NOTES:
1. FLEXIBLE CONNECTIONS REQUIRED FOR PIPE CONNECTIONS ONLY.
2. RESTRAINT IS NOT REQUIRED IF THE PIPING OR DUCTWORK IS SUPPORTED BY HANGERS WHERE EACH
HANGER IS 12 INCHES OR LESS IN LENGTH FROM THE TOP OF THE PIPE OR DUCT TO THE SUPPORTING
STRUCTURE. WHERE PIPES OR DUCTS ARE SUPPORTED ON A TRAPEZE, THE TRAPEZE SHALL BE
SUPPORTED BY HANGERS HAVING A LENGTH OF 12 INCHES OR LESS. WHERE ROD HANGERS ARE
USED, THEY SHALL BE EQUIPPED WITH SWIVELS, EYE NUTS OR OTHER DEVICES TO PREVENT BENDING
IN THE ROD.
3. ALL PIPING AND DUCTWORK, REGARDLESS OF SIZE, DESIGNED TO CARRY TOXIC, HIGHLY TOXIC, OR
EXPLOSIVE GASES OR USED FOR SMOKE CONTROL MUST BE RESTRAINED.
4. COMPONENT CERTIFICATION MUST BE SUPPLIED BY THE EQUIPMENT MANUFACTURER AT THE TIME OF
SUBMITTAL FOR REVIEW BY THE ENGINEER OF RECORD.
SEISMIC AND WIND REQUIREMENTS
FOR MECHANICAL SYSTEMS
INFORMATION FOR IBC-2018/ASCE 7-16
SEISMIC DESIGN CATEGORY: C
RISK CATEGORY: IV
FLOOR MOUNTED
WALL MOUNTED
COMPONENT SUPPORTS
NOT INLINE W/
DUCT/PIPE
INLINE W/
DUCT/PIPE
SUSPENDED
EQUIPMENT
REQUIRED
(SEE NOTE 4)
RESTRAIN ALL
SEISMIC
RESTRAINT
REQUIREMENT
1.5
RESTRAIN ALL
RESTRAIN IF > 75 LBS
PROVIDE FLEX .
CONN. (SEE NOTE 1)
13.2.2
13.1.4.5
ASCE 7-16
REFERENCE
13.1.4.5
13.1.4.5
13.6.5
13.1.4.5
13.6.7
COMPONENT IMPORTANCE
FACTOR (Ip)
SUSPENDED DUCTILE
PIPING
(STEEL, AL, CU, ETC.)
RESTRAIN IF > 2"
(SEE NOTE 2)
13.6.8.3.3.a
SUSPENDED NON-DUCTILE
PIPING (CAST IRON,
PLASTIC, CERAMIC)
RESTRAIN ALL
(SEE NOTE 2)
13.6.8.3.3
SUSPENDED PIPE
ON TRAPEZE
RESTRAIN IF ANY PIPE
ON TRAPEZE >2"
RESTRAIN IF TOTAL
WEIGHT OF PIPES ON
TRAPEZE >10 LBS/FT
(SEE NOTE 2)
13.6.8.3.1
DUCTWORK
RESTRAIN IF > 6 SQ.
FT. OR > 17 LBS/FT
(SEE NOTES 2,3)
13.6.7
MULTIPLE DUCTS ON
TRAPEZE
RESTRAIN IF TOTAL
WEIGHT OF DUCTS ON
TRAPEZE > 10 LBS/FT
(SEE NOTES 2,3)
13.6.7
1. PER 2018 INTERNATIONAL BUILDING CODE, MECHANICAL EQUIPMENT AND COMPONENTS,
INCLUDING THEIR SUPPORTS AND ATTACHMENTS, SHALL BE DESIGNED FOR SEISMIC FORCES IN
ACCORDANCE WITH CHAPTER 13 OF ASCE 7-16.
2. EXTERIOR EQUIPMENT (INCLUDING ROOF CURBS AND ROOF RAILS) EXPOSED TO WIND SHALL BE
DESIGNED AND INSTALLED TO RESIST THE WIND PRESSURES DETERMINED IN ACCORDANCE WITH
CHAPTERS 26 THROUGH 29 OF ASCE 7-16.
3. WHERE DESIGN FOR SEISMIC AND WIND LOADS IS REQUIRED, THE MORE DEMANDING FORCE MUST
BE USED.
4. REFERENCE THE STRUCTURAL DRAWINGS FOR SITE SPECIFIC INFORMATION ON SEISMIC DESIGN
CATEGORY, WIND SPEED, ETC.
5. USE TABLE BELOW TO DETERMINE SEISMIC RESTRAINT REQUIREMENTS FOR EACH COMPONENT.
6. FOR ALL COMPONENTS REQUIRING SEISMIC RESTRAINT, THE COMPONENT SUPPORTS AND
ATTACHMENTS SHALL BE DESIGNED BY A REGISTERED DESIGN PROFESSIONAL.
7. WHERE SEISMIC RESTRAINT IS REQUIRED, HOUSEKEEPING PADS NEEDED FOR THE INSTALLATION
OF EQUIPMENT UNDER THIS CONTRACT MUST BE DESIGNED BY THE SEISMIC ENGINEER. DO NOT
POUR ANY HOUSEKEEPING PADS PRIOR TO THE RECEIPT OF APPROVED SEISMIC SUBMITTAL.
8. SEISMIC RESTRAINTS FOR DUCTWORK, PIPING AND CONDUIT MUST BE SHOWN ON SEISMIC
SUBMITTAL LAYOUT DRAWINGS SHOWING SPECIFIC RESTRAINT LOCATIONS ALONG WITH
ACCOMPANYING DETAILS AND CALCULATIONS.
RESTRAIN ALL
RESTRAIN ALL
RESTRAIN ALL
AIR CONTROL VALVEACV
EXISTING TO BE DEMOLISHEDETBD
EXISTING TO REMAINETR
MEDIUM PRESSURE STEAM (30 PSI)MPS
MEDIUM PRESSURE STEAM (30 PSI)
CONDENSATE RETURN
MPR
VARIABLE FREQUENCY DRIVE
(VFD) NOTES
1. ALL VFD'S SHALL COMPLY WITH IEEE 519-2993. VFD
MANUFACTURER SHALL PROVIDE A DISTORTION
ANALYSIS.
2. ALL VFD'S SHALL BE LIMITED TO A MAXIMUM 60 HZ.
THE TEST AND BALANCE FIRM MAY NOT INCREASE THE
FREQUENCY ON ANY VFD ABOVE 60 HZ TO ACHIEVE
THE AIRFLOWS SHOWN ON THESE CONSTRUCTION
DOCUMENTS.
DUCT SEALING REQUIREMENTS
4.0" PRESSURE CLASSMEDIUM PRESSURE SUPPLY
DUCT PRESSURE REQUIREMENTS
PRESSURE CLASSDUCT SYSTEM
2.0" PRESSURE CLASSLOW PRESSURE SUPPLY
LOW PRESSURE RETURN
LOW PRESSURE EXHAUST
1. ALL DUCTWORK SHALL BE SEALED IN ACCORDANCE WITH
SEAL CLASS "A"
2. SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, WALL
PENETRATIONS, AND DUCT CONNECTIONS. PRESSURE SENSITIVE
TAPE SHALL NOT BE USED AS THE PRIMARY SEALANT, UNLESS IT
HAS BEEN CERTIFIED TO COMPLY WITH UL-181A OR UL181B BY AN
INDEPENDENT TESTING LABORATORY AND THE TAPE IS USED IN
ACCORDANCE WITH THAT CERTIFICATION.
3. LONGITUDINAL SEAMS ARE JOINTS ORIENTED IN THE
DIRECTION OF AIRFLOW. TRANSVERSE JOINTS ARE CONNECTIONS
OF TWO DUCT SECTIONS ORIENTED PERPENDICULAR TO AIRFLOW.
DUCT WALL PENETRATIONS ARE OPENINGS MADE BY ANY SCREW
FASTENER, PIPE, ROD, OR WIRE. SPIRAL LOCK SEAMS IN ROUND
DUCTS NEED NOT BE SEALED. ALL OTHER CONNECTIONS ARE
CONSIDERED TRANSVERSE JOINTS, INCLUDING BUT NOT LIMITED
TO SPIN-INS, TAPS AND OTHER BRANCH CONNECTIONS, ACCESS
DOORS FRAMES AND JAMBS, DUCT CONNECTIONS TO EQUIPMENT,
ETC.
2.0" PRESSURE CLASS
2.0" PRESSURE CLASS
PHASING & PRE-CONSTRUCTION NOTES
1. CONTRACTOR SHALL REVIEW THE PHASING REQUIREMENTS AND NOTES
INDICATED ON PHASING SHEET A051. SOME EXISTING AREAS SHALL
REMAIN OCCUPIED MONDAY-SUNDAY. COORDINATE PHASING,
DEMOLITION, NEW WORK, AND ANY SHUT-DOWN OF EXISTING SYSTEMS
WITH THE VA COR.
2. PRIOR TO BIDDING, THE CONTRACTOR SHALL CONDUCT A THOROUGH
SURVEY OF EXISTING CONDITIONS. DISCREPANCIES BETWEEN THE
CONTRACT DOCUMENTS AND EXISTING CONDITIONS SHALL BE BROUGHT
TO THE ATTENTION OF THE VA COR, ARCHITECT, AND ENGINEER AT
LEAST ONE WEEK PRIOR TO THE BID DATE. SUBMISSION OF A BID
INDICATES THE CONTRACTOR IS FAMILIAR WITH EXISTING CONDITIONS
AND HAS INCLUDED IN HIS BID ALL WORK NECESSARY TO INSTALL THIS
PROJECT.
3. PRIOR TO BIDDING, THE CONTRACTOR SHALL CAREFULLY EXAMINE AND
FAMILIARIZE HIMSELF WITH THE PHASING REQUIREMENTS, EXISTING
CONDITIONS, AND NEW WORK SHOWN ON THE CONSTRUCTION
DOCUMENTS. SUBMISSION OF A PROPOSAL SHALL BE CONSIDERED AS
EVIDENCE THAT SUCH A REVIEW AND EXAMINATION HAS BEEN
PERFORMED.
4. THE CONTRACTOR SHALL PROVIDE TEMPORARY HEATING & COOLING AS
REQUIRED TO ALLOW THE AREAS INDICATED ON PHASING SHEET A051
TO REMAIN OCCUPIED DURING CONSTRUCTION. PORTABLE HVAC UNITS
SHALL BE PROVIDED AS REQUIRED. THE CONTRACTOR HAS THE OPTION
OF TYING PORTABLE HVAC UNITS INTO EXISTING SYSTEMS DURING
CONSTRUCTION.
5. THE CONTRACTOR SHALL INCLUDE IN HIS BID ALL WORK NEEDING TO BE
DONE AFTER HOURS OR ON WEEKENDS, ANY WORK REQUIRING
SHUTDOWNS, ANY WORK THAT MAY REQUIRE OVERTIME, AND ANY NEED
FOR TEMPORARY HEATING & COOLING. LATER CLAIMS FOR EXTRA
LABOR OR MATERIALS REQUIRED DUE TO DIFFICULTIES ENCOUNTERED
WILL NOT BE RECOGNIZED.
6. THE SPACE ABOVE CEILINGS IS VERY CONGESTED WITH EXISTING
MECHANICAL EQUIPMENT, DUCTWORK, MECHANICAL PIPING, PLUMBING
PIPING, SPRINKLER PIPING, ELECTRICAL CONDUIT, LIGHTS, CABLE
TRAYS, LOOSE CABLES, ABANDONED ITEMS, ETC. INSTALLATION OF
NEW EQUIPMENT, DUCTWORK, AND PIPING WILL BE CHALLENGING. THE
CONTRACTOR SHALL RELOCATE, RE-SIZE, AND/OR RE-ROUTE
EQUIPMENT, DUCTWORK, AND PIPING (INCLUDING EXISTING TO
REMAIN) AS REQUIRED FOR THE NEW WORK AND TO MAINTAIN THE
ARCHITECT'S CEILING HEIGHTS.
7. ANY AIR INTAKES ADJACENT TO WORK AREAS SHALL BE FILTERED FROM
DUST AND DEBRIS WITH MINIMUM MERV 13 FILTRATION.
8. ALL PHASES SHALL BE KEPT UNDER NEGATIVE PRESSURE AND
EXHAUSTED DIRECTLY OUTDOORS.
TB TERMINAL BOX
DOMESTIC COLD WATER FOR
MECHANICAL EQUIPMENT
(INSTALLED BY P.C.)
DCW
MECHANICAL DOMESTIC COLD WATER
FOR MECHANICAL EQUIPMENT
(INSTALLED BY M.C.)
MDCW
ELECTRICAL CONTRACTORE.C.
EXISTING TO BE RELOCATEDETBR
COORDINATION DRAWINGS
1. A MEETING SHALL BE ARRANGED BY THE CONTRACTOR AND TAKE PLACE PRIOR TO STARTING THE
COORDINATION DRAWINGS. THIS MEETING SHALL INCLUDE AT A MINIMUM THE CONTRACTOR AND THE VA SUCH THAT WE CAN CONFIRM THE REQUIREMENTS OF THE COORDINATION DRAWINGS PRIOR TO
THEM BEING SUBMITTED.
2. THE CONTRACTOR SHALL COORDINATE WITH OTHER TRADES SO THAT THE FOLLOWING LISTS OF ITEMS CAN BE INDICATED ON A COMMON SET OF PLANS. FLOOR PLANS AND SECTIONS ARE TO BE DRAWN TO
SCALE IN ALL CONGESTED AREAS (SUCH AS CORRIDORS, CHASES, AND EQUIPMENT ROOMS) AND
SPECIFIC AREAS NOTED IN THESE DOCUMENTS. THESE SHALL BE SUBMITTED COLLECTIVELY FROM ALL DISCIPLINES INTO ONE OVERALL DOCUMENT FOR REVIEW BY THE ENGINEER ON AN AS NEEDED BASIS
OR WHERE SPECIFICALLY DIRECTED WITHIN THE CONTRACT DOCUMENTS. THESE COORDINATION
DRAWINGS SHALL BE SUBMITTED FOR REVIEW PRIOR TO ANY OTHER INDIVIDUAL PRODUCT DATA OR
FABRICATION DRAWINGS. SHOW THE FOLLOWING AT A MINIMUM:
• CEILING.
• FLOOR.
• ROOF OR FLOOR DECKING ABOVE.
• STRUCTURAL ELEMENTS.
• LIGHT FIXTURES.
• LARGE ELECTRICAL OR TELECOM CONDUITS AND/OR PULL BOXES.
• HVAC DUCTWORK.
• HVAC EQUIPMENT ABOVE CEILING, INDICATING SERVICE CLEARANCES.
• HVAC PIPING.
• PLUMBING PIPING.
• SPRINKLER PIPING.
• MOUNTING RACKS AND SUPPORT ASSEMBLIES FOR ASSOCIATED PIPING/DUCTWORK.
3. IT IS IMPORTANT TO NOTE THAT DUCTWORK/PIPING/CABLE TRAY, ETC. CANNOT BE FABRICATED UNTIL THE COORDINATION DRAWINGS HAVE BEEN COMPILED, SUBMITTED, AND APPROVED. ANY MATERIAL
PROCUREMENT OR INSTALLATION WORK COMMENCED PRIOR TO APPROVAL IS TAKEN AT THE RISK OF
THE CONTRACTOR AND MAY HAVE TO BE MODIFIED/MOVED AT THEIR COST.
REMOTE OPERATED MANUAL VOLUME DAMPER
WITH MINI CEILING CABLE TERMINATION - REFER
TO DETAILDUCT
AEROSOL INJECTION PORT ASSEMBLY WITH 3/4"
FLEXIBLE TUBING TO DUCT CONNECTION PLATE
LOCATED IMMEDIATELY DOWNSTREAM OF REMOTE
OPERATED DAMPER
H
ZONE HUMIDITY SENSOR. MOUNT 4'-0" A.F.F.
PER THE ACCESSIBILITY CODE.
EXHAUST AIREA
LOUVERLVR
LOW PRESSURE STEAM (10 PSI)
FOR STEAM-TO-STEAM HUMIDIFIERS
LPS
LOW PRESSURE STEAM (10 PSI)
FOR STEAM-TO-STEAM HUMIDIFIERS
LPR
PM
PRESSURE MONITOR. MOUNT 4'-0" A.F.F. PER
THE ACCESSIBILITY CODE.
CONTRACTING OFFICER'S REPRESENTATIVECOR
P -OR-
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: PRIME CONTRACTOR: Office of Construction and Facilities Management
558-17-233
Durham VAMC Durham NC
REPLACE PHARMACY AHUS
RENOVATE F1204 & N1004
COMPOUNDING PHARMACIES
102 THIRD AVENUE NORTHEAST
HICKORY, NORTH CAROLINA 28601
PHONE: 828.315.9962
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
NC License No: C-2848
AME Project No: 18104
VA FORM 08-6231
F
E
D
C
B
A
M-001
WEBFFR
MECHANICAL - GENERAL NOTES AND LEGENDS
FINAL CONSTRUCTION DOCUMENTS - FOR BIDDING PURPOSES ONLY
June 30, 2020
32x20
/1 x
30x16
16x14
8ø ø ø ø ø
/2 x
18x12
ETR
VAV-30-2-10
ETR
VAV-30-2-12
ETR
30-2-14
ETBR
30-2-10
24x10 x x
ETBR
VAV-30-2-16
ETBD
VAV-30-2-11
7 7
7 7
18x1215x1212x10
12x10 x
ETR
325 CFM
ETR
325 CFM
ETR
325 CFM
/1
33/16
/1
INVESTIGATIONAL
PHARMACIST
F1204
ONCOLOGY
DRUG PREP
F1204D
STORAGE
F1204F
V ADD
F1204A
HSK
F1204B
TOILET
F1204C
CHIEF
F1215
H W
S
H W
R
H W
S
H W
R
H W
S
H W
R
2 1/2" HWS
1 1/2" HWR10
/4
H
W R
/4
H
W S
/4
H
W S
/4
H
W R
/4
H
W R
/4
H
W S
ETR
EXHAUST
LOUVER
x
70x30 x x
ETBD
EF-54
x
8ø
8ø
/2 x x
34x20 x
34x20
4" CWR
4" CWS
6" CWR
ETR
RELIEF
AIR
FAN
36/18
44x30
2" MPS 2 1/2" MPS 3" MPS
2" MPR2" MPR
C W
S
C W
R
2" MPS
/2
M P R
1 1/2" MPR
2" MPS
INTERSTITIAL
MECHANICAL
SPACE
F2121
INTERSTITIAL
MECHANICAL
SPACE
F2121
SMOKE TIGHT…
This is the start of the file's text. The full file is on GovTribe.