36C24618B0613-002.pdf
PDF 15 MB Posted
- Solicitation number
- 36C24618B0613
About this file
36C24618B0613 S02 - Final Design Drawings.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24618B0613-00003000.docx | DOCX document | |
| 36C24618B0613-00003001.pdf | ||
| 36C24618B0613-00003002.pdf | ||
| 36C24618B0613-00002000.docx | DOCX document | |
| 36C24618B0613-00001000.docx | DOCX document | |
| 36C24618B0613-001.docx | DOCX document | |
| 36C24618B0613-004.pdf | ||
| 36C24618B0613-003.pdf | ||
| 36C24618B0613-000.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RENOVATE
ADMINISTRATIVE
BUILDING 66
590-14-102
NO. DESCRIPTION DATE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned
Small Business
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
100% FINAL DESIGN - NOT FOR CONSTRUCTION
FULLY SPRINKLERED
T
M C
EWNO
M
O
OF VIRG
N
A I
I
LA H
GERALD P. LAMINA JR.
Lic. No. 039989
ANOISSEF
O
R P
L E N G I N E
E R
COVER SHEET
PRE-EVALUATION,
AND DRAWING INDEX
66-G-001
DSST
DOOR TAG
1i
1i
M349
1i
EXISTING DOOR
NEW DOOR
DEMO DOOR
NEW WALL
EXISTING WALL
DEMO WALL OR ITEMS
ABOVE OR BELOW
WALL PROTECTION TAG
WALL TAG
ROOM NUMBER
REVISION TAG
EQUIPMENT TAG
TOILET ACCESSORY TAG
DEMOLITION NOTE
NEW WORK NOTE
A810
DEMO ROOM NUMBER
A101
SIM
CURTAINWALL AND
WINDOW MARKER1i
1i
INTERIOR ELEVATION
MARKER
SECTION OR WALL
SECTION NUMBER
COLUMN GRID NUMBER
EXISTING COLUMN
GRID NUMBER
EXISTING WINDOW MARKER
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Date
Project No.Drawing Title
Building No.
Location
Drawn by:Checked by:
Project Title
SHEET OF
Drawing No.APPROVED: PROJECT DIRECTOR www.pfa-architect.com
ARCHITECTURE, PLANNING, INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510
Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
1010 Kings Highway South Building One - 1st Floor Cherry Hill, NJ 08034 Tel (856) 429-4000 Fax (856) 429-5002
F
E
D
C
E
B
A th re e-ei gh th s in ch o ne fo ot on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ha lf in ch on e fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
Building 66
/1
9/
:5 8:
A
M
66-A001
HAMPTON, VIRGINIA
Renovate Administrative Bldg.
jht ljh12-19-2014
590-14-102Architectural Abbreviations and Legends
Abbreviations
TERRAZZOTER
EXISTING TO REMAINETR
BT BRICK TILE
ON CENTERO.C.
MOUNTINGMTG
CERAMIC WALL PAVER TILECWPT
RA
R
QT.
PTD
PNT
PLAM
CG
COL
CLG, CLNG
ACT
A.F.F.
CORNER GUARD
CEILING
COLUMN
ACOUSTICAL TILE
ABOVE FINISH FLOOR
VERT
VB.
TYP
SUSP.
STOR
AT@
GWB
FIN
EXIST.
EWC
ELEV
ELEC
CORR
CONT. CONTINUOUS
CORRIDOR
ELECTRIC(AL)
ELEVATOR
EXISTING
FINISH(ED)
NIC.
MTL
MECH
MAX
L
HT
HR
HDWR
NOT IN CONTRACT
HARDWARE
HOUR
HEIGHT
LENGTH
MAXIMUM
MECHANICAL
METAL
CFCI
CFOI
OFOI
OFCI
CONTRACTOR FURNISHED
CONTRACTOR FURNISHED
OWNER FURNISHED
OWNER FURNISHED
ELECTRIC WATER
GYPSUM
SIM
CONCRETECONC.
PLASTIC LAMINATE
VINYL BASE
VERTICAL
TYPICAL
PAINT
PAINTED
QUARRY TILE
RISER
RETURN AIR
SIMILAR
STORAGE
SUSPENDED
DIAMETER
ANGLE
CENTER LINE
EXP EXPOSED
TO MATCH EXISTINGTME
COOLER
WALLBOARD
CONTRACTOR INSTALLED
OWNER INSTALLED
CONTRACTOR INSTALLED
OWNER INSTALLED
CL
O
Legend
MB MILLWORK BASE VAT VINYL ASBESTOS TILE
RST RESILIENT STAIR TREAD
GRT GROUT
CPT CARPET TILE
SV. SHEET VINYL
WT WALL TILE
QR. QUARTER ROUND
SS SOLID SURFACE
TB. TILE BASE
SVT. SOLID VINYL TILE
MT. MOSAIC TILE
RT RUBBER TILE
WP WAINSCOTING PANEL
TP. TOILET PARTITION
PT PORCELAIN TILE
FT FLOOR TILE, MOSAIC
TR. TRIM ACCESSORY
CT CERAMIC TILE
NO.
AI
NI
GR
IV
FOHTLAEWNO
M M
O
C JOSEPH H. TROST
ARCHITECT
1 HR RATED WALL
BUILDING REGULATION DATA
APPLICABLE CODES AND STANDARDS
NFPA 101, 2012
INTERNATIONAL BUILDING CODE (IBC 2012)
NFPA-101 LIFE SAFETY CODE (2012)
NFPA-220 STANDARD TYPE OF BUILDING CONSTRUCTION (2012)
NFPA-10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS (2012)
NFPA-70 NATIONAL ELECTRIC CODE (2008)
NFPA-101 LIFE SAFETY CODE (2012) CHAPTER 43.6 RECONSTRUCTION
CLASSIFICATION OF OCCUPANCY:
1. EXISTING BUILDING OCCUPANCY CHAPTER 39.
BUILDING HAS AUTOMATIC FIRE SUPPRESSION SYSTEM.
HAZARDOUS AREAS SHALL BE PROTECTED IN ACCORDANCE WITH TABLE 18.3.2.1 AS FOLLOWS:
CONSTRUCTION TYPE:
1. NFPA 220 (2012 EDITION) TYPE V (000), FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13.
MEANS OF EGRESS:
1. MAX ALLOWED LENGTH OF EXIT ACCESS 300 FEET PER PARAGRAPH 39.2.6.2.2; MAX TRAVEL IN THIS FACILITY IS
LESS THAN 300 FEET.
2. OCCUPANT LOAD PER TABLE 7.3.1.3
100 GSF PER PERSON
19,119 GSF = 192 OCCUPANTS
3. EGRESS WIDTH FOR DOORS AND CORRIDORS REQUIRED IS .20 INCHES X 96 OCCUPANNTS = 18.4" INCHES
(MINIMUM 36 INCHES)
ACTUAL EGRESS CAPACITY IS 72 INCHES (360) PEOPLE.
FINISH REQUIREMENTS (NFPA 101 10.2.2):
EXIT ENCLOSURES / EXIT PASSAGEWAYS: CLASS (A) OR (B)
EXIT ACCESS CORRIDORS & OTHER EXIT WAYS: CLASS (A) OR (B)
ROOMS AND ENCLOSED SPACES: CLASS (A) OR (B)
FLOORS IN EXIT ENCLOSURES, EXIT PASSAGEWAYS AND CORRIDORS
(OTHER THAN WOOD, VINYL, LINOLEUM AND RESILIENT FLOORS W/O FIBER MATERIALS): CLASS (I) OR (II)
FIRE PROTECTION:
AUTOMATIC SPRINKLER SYSTEMS: FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13, PORTABLE FIRE
EXITINSHERS (NFPA 10).
CLASS ABC TYPE; MIN. RATING 2-A (WHERE INDICATED ON LIFE SAFETY PLAN)
MAIXUM TRAVEL DISTANCE: 75'
(FULLY SPRINKLERED)
USE GROUP B, PER SECTION 304
CONSTRUCTION TYPE B, PER SECTION 602.5; 9000 S.F. PER STORY + 200% = 27,000 S.F. PER STORY
AREA: 54,000 GSF (2 STORIES ALLOWED)
AREA OF 1ST FLOOR: 10,400 S.F.
AREA OF 2ND FLOOR: 8,719 S.F.
BUILDING TOTAL: 19,119 GSF
AREA OF RENOVATION 1ST FLOOR: 373 GSF
AREA OF RENOVATION 2ND FLOOR: 7,362 GSF
OCCUPANCY LOAD = 1 PERSON PER 100 S.F.
TOTAL OCCUPANTS: 192 PEOPLE
LIFE SAFETY LEGEND
BUILDING AREA AND HEIGHT LIMITATIONS
2 3 4 5
6 7
8 9 10 11
B
D
A
C
E
107A
103G
C-1
103F
103E
104B
102A
102E 102F 102G 102H 102L
102D 102C102B
EG-1
101B
101A
101C
104C 104D 104E 104F
104G
104A
104J
104I104H
104Q C-2
104P 104O 104N 104M
104L
100 100A
100C
100 100A
103E
103G107A
108B
2.1 2.2 2.3
2.A
202F
202G 202H
202J
201B
202B202C202D
202E
204Q
204B
204K
204A
C-3
203D
203E
201A
201C201
EG-2
2.4
2.B
2.5 2.6
203C
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Date
Project No.Drawing Title
Building No.
Location
Drawn by:Checked by:
Project Title
SHEET OF
Drawing No.APPROVED: PROJECT DIRECTOR www.pfa-architect.com
ARCHITECTURE, PLANNING, INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510
Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
1010 Kings Highway South Building One - 1st Floor Cherry Hill, NJ 08034 Tel (856) 429-4000 Fax (856) 429-5002
F
E
D
C
E
B
A th re e-ei gh th s in ch o ne fo ot on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ha lf in ch on e fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
Building 66
/1
9/
:5 8:
A
M
66-LS110
HAMPTON, VIRGINIA
Renovate Administrative Bldg.
jht ljh12-19-2014
590-14-102Life Safety- First and Second Floor
1/8" = 1'-0"
FIRST FLOOR - LIFE SAFETY
1/8" = 1'-0"
SECOND FLOOR - LIFE SAFETY
NO.
AI
NI
GR
IV
FOHTLAEWNO
M M
O
D103
D102LD102H
D102GD102FD102E
D102A
D108
D104CC
D102B D102C D102D
DC-1
D106
DEG-1
D101B
D101
D101C
D101A
D100 D100A
D107B
D107A
D104P D104O D104N D104M D104L
D105
D104A
D104G
D104FD104ED104DD104C
D104B
D104Q
D104
DC-2
D104S D104I D104J
2 3 4 5
6 7
8 9 10 11
B
D
A
C
E
D100C
7 7
15 15
TYP
TYP
17 17
PIPING PIPING
PIPING
21 21
D105B
D105C
D105A D103A
D103B
PHASE III PHASE I
PHASE III PHASE I
GENERAL DEMOLITION NOTES
• ARCHITECTURAL DEMOLITION DRAWINGS INDICATE IN GENERAL, THE EXTENT OF ARCHITECTURAL DEMOLITION. SEE OTHER DISCIPLES DRAWINGS FOR EXTENT OF STRUCTURAL , MECHANICAL, AND ELECTRICAL DEMOLITION. REMOVE ALL ASSOCIATED APPURTENANCES NOT REQUIRED IN THE NEW WORK, ALL ABANDONED ITEMS, AND ALL ITEMS REQUIRED FOR THE INSTALLATION OF NEW WORK, TO PROVIDE FOR A COMPLETE PROJECT. ITEMS NOT SPECIFICALLY INDICATED THAT ARE QUESTIONABLE FOR REMOVAL SHALL BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR A DECISION.
• THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS PRIOR TO
THE START OF CONSTRUCTION.
• THE CONTRACTOR SHALL PATCH ALL EXISTING SURFACES TO MATCH EXISTING WHERE AFFECTED BY CONSTRUCTION OPERATIONS, INCLUDING BUT NOT LIMITED TO PLUMBING, MECHANICAL AND ELECTRICAL
WORK.
• THE CONTRACTOR SHALL PATCH NAIL HOLES, ETC, AND REMOVE MISCELLANEOUS APPURTENANCES ON
EXISTING WALLS TO BE PAINTED OR COVERED WITH WALL COVERING.
• ALL EXISTING FLOORING MATERIALS WHICH ARE TO REMAIN IN PLACE SHALL BE COMPLETELY CLEANED AND
STRIPPED OF WAX IN ORDER TO RECEIVE NEW FINISHES.
• ALL NEW WORK SHALL ALIGN WITH EXISTING WHERE THEY INTERSECT UNLESS OTHERWISE NOTED.
• THE CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING SURFACES WHICH WERE PREVIOUSLY DAMAGED PRIOR TO CONSTRUCTION OPERATIONS IF VISIBLE AFTER NEW WORK IS COMPLETE, REGARDLESS IF THE ITEM
WAS SPECIFICALLY NOTED OR NOT.
• THE CONTRACTOR SHALL REMOVE AND PATCH ANY AREAS UNCOVERED WHERE WOOD NAILERS OR GROUNDS ARE FOUND TO EXIST BEHIND ANY TRIM ITEMS OR EQUIPMENT REMOVED. WALLS SHALL BE MADE FLUSH WITH
EXISTING ADJACENT SURFACES AND READY TO RECEIVE NEW FINISHES.
• IF ANY ASBESTOS CONTAINING MATERIAL IS ENCOUNTERED DURING THE COURSE OF CONSTRUCTION OPERATIONS WHICH IS NOT INDICATED ON THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL NOTIFY THE
ARCHITECT IMMEDIATELY.
• WHERE EXISTING VINYL WALL COVERING IS REMOVED ON EXISTING WALLS TO REMAIN, THE CONTRACTOR SHALL PATCH AND REPAIR WALL AS REQUIRED TO PROVIDE A LEVEL AND TRUE SURFACES ON WHICH TO
INSTALL NEW FINISHES.
• WHERE EXISTING CERAMIC TILE IS REMOVED FROM EXISTING WALLS TO REMAIN, THE CONTRACTOR SHALL LEVEL WALL WITH PLASTER AS REQUIRED TO PROVIDE A LEVEL AND TRUE SURFACES ON WHICH TO INSTALL
NEW FINISHES.
• WHERE EXISTING CERAMIC TILE IS REMOVED FROM CONCRETE FLOORS TO REMAIN, THE CONTRACTOR SHALL LEVEL FLOOR AREAS WITH CONCRETE AS REQUIRED TO BE LEVEL WITH ADJACENT FLOOR SURFACES.
• ALL SIGNAGE WHICH OCCURS ON WALL OR ON DOORS TO BE REMOVED SHALL BE REMOVED BY THE
CONTRACTOR AND TURNED OVER TO THE OWNER.
• ALL FINISHES LISTED IN THE DEMOLITION SCHEDULE SHALL BE REMOVED COMPLETELY UNLESS INDICATED OTHERWISE. DEMOTION SHALL INCLUDE BACKINGS, MASTIC AND GLUES, SETTING BEDS, AND SUBSTRATE AS
REQUIRED TO PREPARE THE MATERIAL FOR NEW WORK AND/OR FINISHES.
• ALL NOTES, REMARKS AND/OR SCHEDULES ON THIS SHEET ARE FOR THIS SHEET ONLY UNLESS OTHERWISE
NOTED.
• EXISTING HAND RAIL AND BUMPER GUARD SHALL BE REMOVED AND TURNED OVER TO THE OWNER.
• ALL EXISTING SMOKE DETECTORS, AND SPEAKERS TO REMAIN AND REWORKED WITH NEW CEILING SYSTEM.
• EXISTING WALL FINISHES TO BE VERIFIED AND PREPPED ACCORDINGLY FOR NEW FINISHES SCHEDULES - BY
CONTRACTOR.
• DESIGN INTENT IS TO UPGRADE ALL FINISHES TO FULLEST EXTENT.
• ALL EXISTING ACCESSORY / EQUIPMENT ITEMS: SECURITY CAMERAS, WIRELESS CONNECTION BOXES, EMERGENCY LIGHT FIXTURES, WINDOW COVERINGS, CEILING AND WALL MOUNTED SPEAKERS, THERMOSTAT CONTROLS, RAISED OUTETS ON CMU WALLS, PUSH BUTTON CONTROL BOXES, FIRE PULLS AND FIRE EXTINGUISHERS SHALL BE FIELD VERIFIED BY THE CONTRACTOR FOR WORKING CAPACITY, LOCATION AND TYPE. RETAIN ITEMS FOR INSTALLATION IN EXISTING LOCATION UNLESS OTHER WISE NOTED. REPAIR AND REPLACE ITEMS AS NECCESARY; MATCH EXISTING. SEE M.E.P. DRAWINGS FOR EXTENT OF WORK.
• OWNER SHALL BE RESPONSIBLE FOR REMOVING, REPLACING, SPECIFYING AND COORDINATING EXISTING FF & E ITEMS, INTERIOR SIGNAGE, AS WELL AS ANY WALL MOUNTED DISPLAY ITEMS PRIOR TO PROJECT COMMENCEMENT. CONTRACTOR SHALL WORK WITH OWNER TO STORE, PROTECT AND RE-INSTALL ITEMS AS
NECCESARY.
DEMOLITION NOTES
1. REMOVE EXISTING DOOR, FRAME AND HARDWARE IN ITS ENTIRETY. SALVAGE ALL HARDWARE AND TURN OVER TO
OWNER. REMOVE EXISTING GLASS ARCH TRANSOM WINDOW ABOVE.
2. REMOVE EXISTING PLUMBING FIXTURES AND TOILET ACCESSORIES IN THEIR ENTIRETY. SEE PLUMBING DRAWINGS FOR
EXTENT OF WORK.
3. REMOVE EXISTING FLOOR DRAIN IN ITS ENTIRETY. PATCH VOIDS TO MATCH EXISTING SLAB. SEE PLUMBING DRAWINGS
FOR EXTENT OF WORK.
4. REMOVE EXISTING DOOR, FRAME, AND HARDWARE IN ITS ENTIRETY. INCLUDING BUT NOT LIMITED TO ALL JAMB
ANCHORS AND DOOR STOPS. SALVAGE ALL DOOR HARDWARE AND TURN OVER TO OWNER.
5. REMOVE TOILET PARTITION IN ITS ENTIRETY.
6. REMOVE METAL STUD AND GYPSUM WALL BOARD PARTITION IN ITS ENTIRETY..
7. REMOVE EXISTING WINDOW AND HARDWARE IN ITS ENTIRETY. REMOVE EXISTING LOUVER IN IT'S ENTIRETY; PREP
OPENING TO RECEIVE NEW LOUVER, SEE SHEET A801.
8. REMOVE EXISTING WALL WAINSCOTING, WALL BASE AND CHAIR RAIL IN ITS ENTIRETY.
9. REMOVE EXISTING NURSE CALL CONNECTIONS AND BOX IN ITS ENTIRETY. SEE ELECTRICAL DRAWINGS FOR EXTENT
OF WORK.
10. REMOVE RADIATOR UNIT IN ITS ENTIRETY AND TURN OVER TO OWNER. SEE MECHANICAL, ELECTRICAL, PLUMBING
DRAWINGS FOR EXTENT OF WORK.
11. REMOVE EXISTING PARTIAL HEIGHT CHASE WALL AND CORRESPONDING CONNECTIONS.
12. REMOVE ALL PLUMBING CONNECTIONS NOT UTILIZED. SEE PLUMBING DRAWINGS FOR EXTENT OF WORK. RE-DIRECT
ALL EXPOSED PVC PIPES TO BE ALIGNED TO WALL OR CEILING AS NECCESARY.
13. REMOVE 2" THICK, 3/4" HEIGHT WALL VINYL WRAPPED PLYWOOD PANEL IN ITS ENTIRETY.
14. NOT USED.
15. REMOVE EXISTING ASBESTOS VINYL COMPOSITION TILE IN ITS ENTIRETY. PROVIDE ASBESTOS ABATEMENT AND
REPAIR SUBSTRATE AS NEEDED TO BE CLEAN AND LEVEL TO RECIEVE NEW FINISHES.
16. REMOVE METAL ACCESS WALL PANEL.
17. REMOVE EXISTING VINYL COMPOSITION TILE IN ITS ENTIRETY. PREP AND REPAIR SUBSTRATE AS NEEDED TO BE
CLEAN AND LEVEL TO RECIEVE NEW FINISHES. SEE ASBESTOS PLAN FOR EXTENT OF WORK.
18. REMOVE EXISTING AIR HANDLING UNIT. SEE MECHANICAL DRAWINGS FOR EXTENT OF WORK.
19. REMOVE EXISTING MASONRY WALL IN IT'S ENTIRETY.
20. REMOVE EXISTING DOOR, FRAME, HARDWARE AND MASONRY ABOVE IN ITS ENTIRETY. TURN HARDWARE OVER TO
OWNER,
21. REMOVE EXISTING FLOOR AND FRAMING AS REQUIRED TO INSTALL NEW STRUCTURAL SUPPORT SYSTEM. SEE
STRUCTURAL DRAWINGS FOR EXTENT OF WORK.
22. REMOVE EXISTING DOOR AND HARDWARE IN IT'S ENTIRETY. FRAME TO REMAIN. PREP FRAME TO RECIEVE NEW
DOOR HARDWARE.
*** DEMOLITION NOTES APPLY TO THIS SHEET ONLY ***
1. EXISTING CEILING TILE AND SUSPENSION SYSTEM SHALL BE REMOVED AND RETAINED FOR REUSE AS REQUIRED TO
INSTALL NEW DUCKWORK.
2. UNLESS INDICATED BY DASHED LINES, EXISTING CMU OR GWB TO REMAIN.
3. EXISTING WINDOW SOFFITS TO REMAIN; TYPICAL ALL EXISTING SOFFITS.
DEMOLITION SCHEDULE REMARKS
D203A D202J
D202H
D202G
D202F
D208
D202E
D202D D202C D202B
D201B
D202 D203E
D203B
D203D
DC-3
DEG-2
D201 D201C
D201A D201D
D204Q
D204B
D204
D204K
D205
D204A
122.1 2.2 2.3
2.A
7 7
2.4
2.B
2.5 2.6
PIPING
PIPING
PIPING
TYP
18 18
TYP
D203C
1717 17
PHASE IV PHASE II
PHASE IV PHASE II
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Date
Project No.Drawing Title
Building No.
Location
Drawn by:Checked by:
Project Title
SHEET OF
Drawing No.APPROVED: PROJECT DIRECTOR www.pfa-architect.com
ARCHITECTURE, PLANNING, INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510
Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
1010 Kings Highway South Building One - 1st Floor Cherry Hill, NJ 08034 Tel (856) 429-4000 Fax (856) 429-5002
F
E
D
C
E
B
A th re e-ei gh th s in ch o ne fo ot on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ha lf in ch on e fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
Building 66
/1
9/
:5 8:
A
M
66-AD110
HAMPTON, VIRGINIA
Renovate Administrative Bldg.
jht ljh12-19-2014
590-14-102Demolition Plan - First and Second Floor
1/8" = 1'-0"
FIRST FLOOR DEMOLITION PLAN
DEMOLITION SCHEDULE - FIRST FLOOR
** ALL FINISHES LISTED IN THIS SCHEDULE ARE TO BE REMOVED
COMPLETELY UNLESS OTHERWISE NOTED **
NUMBER FLOOR BASE WALL CEILING REMARKS
D100 CPT RB ETR ETR 2
D100A ETR ETR ETR ETR 1
D100C ETR ETR ETR ETR 1
D101 CPT RB ETR ACT 2
D101A CPT RB ETR ACT 2
D101B ETR ETR ETR ETR 1
D101C ETR ETR ETR ETR 1
D102 VT RB ETR ACT 1
D102A ETR ETR ETR ETR 1
D102B ETR ETR ETR ETR 1
D102C ETR ETR ETR ETR 1
D102D ETR ETR ETR ETR 1
D102E ETR ETR ETR ETR 1
D102F ETR ETR ETR ETR 1
D102G ETR ETR ETR ETR 1
D102H ETR ETR ETR ETR 1
D102L SC - ETR EXP -
D103 VAT / RST RB ETR ACT / PTD
GWB
D103A FT TB CWPT / CT / CMU
/ PTD GWB
ACT 2
D103B FT TB CWPT / CT / CMU
/ PTD GWB
ACT 2
D104 VT ETR ETR ACT 1
D104A VT RB ETR ACT 1,3
D104B VT RB ETR ACT 1
D104C VT RB ETR ACT 1,3
D104D VT RB ETR ACT 1,3
D104E VT RB ETR ACT 1,3
D104F VT RB ETR ACT 1,3
D104G VT RB ETR ACT 1
D104I VT RB ETR ACT 1
D104J VT RB ETR ACT 1
D104L VT RB ETR ACT 1,3
D104M VT RB ETR ACT 1,3
D104N VT RB ETR ACT 1,3
D104O VT RB ETR ACT 1,3
D104P VT RB ETR ACT 1,3
D104Q VT RB ETR ACT 1
D104S VT RB ETR ACT 1
D105 VAT / RST RB ETR ACT / PTD
GWB
D105A FT TB CWPT / CMU /
PTD GWB
ACT 2
D105B CPT RB CWPT / CT / CMU
/ PTD GWB
ACT 2
D105C FT TB CWPT / CT / CMU
/ PTD GWB
ACT 2
D106 ETR ETR ETR ETR 1
D107A CPT RB PTD GWB / CMU ACT 2
D107B CPT RB PTD GWB / CMU /
WP
ACT 2
D108 VAT / RST RB ETR ACT / PTD
GWB
DC-1 CPT RB ETR ACT 2
DC-2 ETR RB ETR ETR 2
DEG-1 ETR ETR ETR ETR -
1/8" = 1'-0"
SECOND FLOOR DEMOLITION PLAN
DEMOLITION SCHEDULE - SECOND FLOOR
** ALL FINISHES LISTED IN THIS SCHEDULE ARE TO BE REMOVED
COMPLETELY UNLESS OTHERWISE NOTED **
NUMBER FLOOR BASE WALL CEILING REMARKS
D201 CPT RB ETR ACT 2
D201A ETR ETR ETR ETR 3
D201C ETR ETR ETR ETR -
D202 ETR ETR PTD GWB / CMU ETR 1
D202A ETR ETR PTD GWB / CMU ETR 1
D202B ETR ETR PTD GWB / CMU ETR 1,3
D202C ETR ETR PTD GWB / CMU ETR 1,3
D202D ETR ETR PTD GWB / CMU ETR 1,3
D202E ETR ETR PTD GWB / CMU ETR 1,3
D202F ETR ETR PTD GWB / CMU ETR 1,3
D202G ETR ETR PTD GWB / CMU ETR 1,3
D202H ETR ETR PTD GWB / CMU ETR 1,3
D202J ETR ETR PTD GWB / CMU ETR 1
D203A CPT RB / TB CWPT / CMU /
PTD GWB
ACT 2
D203B FT TB CWPT / CT / CMU
/ PTD GWB
ACT 2
D203C FT TB CWPT / CT / CMU
/ PTD GWB
ACT 2
D203D FT TB CT / CMU ACT 2
D203E VAT / RST RB PTD GWB / CMU ETR PTD GWB 2
D204 VCT RB PTD GWB / CMU ETR 2,3
D204A VCT RB PTD GWB / CMU ETR 2,3
D204B VCT RB ETR EXP 2
D204K VCT RB PTD GWB / CMU ETR 2,3
D204Q VCT RB PTD GWB / CMU ETR 2,3
D205 VAT / RST RB PTD GWB / CMU ETR PTD GWB 2
D208 VAT / RST RB PTD GWB / CMU ETR PTD GWB 2
DC-3 CPT RB PTD GWB ACT 2
DEG-2 ETR ETR ETR ETR -
NO.
AI
NI
GR
IV
FOHTLAEWNO
M M
O
107A
103G
C-1 103F103E
104B
102A
102E 102F 102G 102H 102L
102D102C102B
EG-1
101B
101A
101C
104C 104D 104E 104F
104G
104A
104J104I104H
104Q C-2
104P 104O 104N 104M 104L
100 100A
100C
2 3 4 5
6 7
8 9 10 11
B
D
A
C
E
100 100A
103E
103G107A
108B
TYP
TYP
6 6
TYP
TYP
9 TYP
TYP
TYP
TYP
9 TYP
TYP
D D D D
B B
19 3316
21LVT
LVT
105B
100C
PHASE III PHASE I
PHASE III PHASE I
202F
202G 202H
202J
201B
202B202C202D
202E
204Q
204B
204K
204A
C-3
203D203
203E
201A
201C201
EG-2
2.1 2.2 2.3
2.A
TYP
TYP
TYP
TYP
TYP
1111 11
TYP
TYP
TYP
2.4
2.B
2.5 2.6
203C
LVT
TYP
TYP
TYP
203C
19 19C C C C
A A
203D
TYP
TYP
11 11
TYP
TYP
20 20
LVT
PHASE IV PHASE II
PHASE IV PHASE II
10 10
10 10 10
• CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR A RESOLUTION. ADJUSTMENTS TO DIMENSIONS AND CONDITIONS SHOWN MAY BE
REQUIRED.
• ALL DIMENSIONS ARE REFERENCED FROM FACE OF STUD AT NEW CONSTRUCTION UNLESS
OTHERWISE NOTED. DIMENSIONS ARE REFERENCED FROM FACE OF FINISH AT EXISTING
CONSTRUCTION.
• ALL DIMENSIONS INDICATED +/- ARE APPROXIMATE AND MUST BE FIELD VERIFIED PRIOR TO THE
START OF CONSTRUCTION.
• PROVIDE SHALL MEAN TO SUPPLY, TO FURNISH AND TO INSTALL COMPLETE WITH ALL ACCESSORIES, PARTS AND/OR SERVICES TO BE READY FOR ITS INTENDED USE.
• WHERE WORK ABUTS OR ADJOINS EXISTING SURFACES WHICH WILL REMAIN EXPOSED, ALIGN NEW
WORK FLUSH WITH EXISTING ADJACENT SURFACES.
• THE CONTRACTOR SHALL MAINTAIN THE EXISTING BUILDING IN A WATER TIGHT CONDITION
THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD. REPAIR DAMAGE CAUSED BY CONSTRUCTION
OPERATIONS. TAKE ALL PRECAUTIONS NECESSARY TO PROTECT THE BUILDING AND ITS OCCUPANTS
DURING THE CONSTRUCTION PERIOD.
• CONTRACTOR SHALL PROVIDE BARRIERS TO PREVENT ENTRY TO THE CONSTRUCTION AREA.
BARRIERS SHALL NOT INTERFERE WITH THE OWNERS USE OF THE SITE.
• THE CONTRACTOR SHALL PROVIDE NEGATIVE PRESSURE IN THE AREA OF RENOVATION TO PREVENT
THE SPREAD OF DUST TO OCCUPIED AREAS OF THE BUILDING.
• ALL NOTES, REMARKS AND/OR SCHEDULES ON THIS SHEET ARE FOR THIS ONLY UNLESS OTHERWISE
NOTED.
• ALL EXISTING ACCESSORY / EQUIPMENT ITEMS: SECURITY CAMERAS, WIRELESS CONNECTION
BOXES, EMERGENCY LIGHT FIXTURES, WINDOW COVERINGS, CEILING AND WALL MOUNTED
SPEAKERS, THERMOSTAT CONTROLS, RAISED OUTETS ON CMU WALLS, PUSH BUTTON CONTROL
BOXES, FIRE PULLS AND FIRE EXTINGUISHERS SHALL BE FIELD VERIFIED BY THE CONTRACTOR FOR WORKING CAPACITY, LOCATION AND TYPE. RETAIN ITEMS FOR INSTALLATION IN EXISTING LOCATION UNLESS OTHER WISE NOTED. REPAIR AND REPLACE ITEMS AS NECCESARY; MATCH EXISTING. SEE
M.E.P. DRAWINGS FOR EXTENT OF WORK.
• OWNER SHALL BE RESPONSIBLE FOR REMOVING, REPLACING, SPECIFYING AND COORDINATING EXISTING FF & E ITEMS, INTERIOR SIGNAGE, AS WELL AS ANY WALL MOUNTED DISPLAY ITEMS PRIOR
TO PROJECT COMMENCEMENT. CONTRACTOR SHALL WORK WITH OWNER TO STORE, PROTECT AND
RE-INSTALL ITEMS AS NECCESARY.
• THE PROJECT IS CONSTRUCTED IN FOUR PHASES. EACH PHASE IS SELF CONTAINED.
GENERAL NEW WORK NOTES
1. INSTALL BLOWN INSULATION @ INTERSECTION OF EXISTING WALL AND NEW CONSTRUCTION, OR EXISTING
WALL AND EXISTING CONSTRUCTION TYP.
2. INSTALL FLOOR MOUNTED TOILET PARTITION.
3. PROVIDE LOUVER IN TOP WINDOW OPENING, APPROXIMATELY 3'-0" WIDE X 1'-0" HIGH. FIELD VERIFY.
4. PROVIDE URINAL. SEE PLUMBING DRAWINGS FOR EXTENT OF WORK.
5. PROVIDE NEW WALL HUNG TOILET. SEE PLUMBING DRAWINGS FOR EXTENT OF WORK.
6. PROVIDE WALL MOUNTED, PREMOLED LAVATORY WITH QUARTZ COUNTERTOP AND HARDWIRED SENSOR
FAUCETS. SEE PLUMBING DRAWINGS FOR EXTENT OF WORK.
7. PROVIDE TOILET ACCESSORIES AND EQUIPMENT. SEE TOILET ACCESSORY SCHEDULE ON SHEET 66-A700.
8. PROVIDE A MIN. 32" WIDE X 36" HIGH LOCKABLE METAL ACCESS PANEL DOOR FOR EXISTING MECHANICAL
CHASE.
9. PROVIDE 1 5/8" MTL STUDS AT 16" O.C. MAX WITH 5/8" GWB. PROVIDE MINERAL WOOL INSULATION
(1-1/2" THICK), EXTEND TO DECK ABOVE.
10. INFILL EXISTING WALL WITH BLOWN INSULATION. EXTEND EXISTING WALL TO DECK ABOVE.
11. INFILL BELOW EXISTING BULLNOSE (4'-0"A.F.F.) HIDDEN BEHIND WALL CONSTRUCTION WITH BLOWN
INSULATION, PATCH HOLES AND FINISH TO MATCH.
12. PREP CMU WALLS AS NECESSARY AND PROVIDE NEW WALL PAINT. PAINT STAIR RAILS AND RISERS.
13. NOT USED.
14. PROVIDE NEW LOUVER TO FIT INSIDE EXISTING OPENING.
15. PROVIDE NEW STAIR TREADS AND LANDING FINISHES.
16. BOX OUT FULL HEIGHT VERTICAL PIPING WITH GYPSUM BOARD WHERE INDICATED. CONTRACTOR TO
FIELD VERIFY USE AND PROVIDE ACCESS PANELS WHERE NECCESARY.
17. PREP, PATCH AND REPAIR SUBSTRATE AS NECCESARY TO RECEIVE NEW FLOOR FINISHES AS
SCHEDULED.
18. PROVIDE NEW WATER COOLER AT THIS LOCATION. CLEAR FLOOR SPACE OF 30" X 48". SEE PLUMBING
DRAWINGS FOR EXTENT OF WORK.
19. PAINT INTERIOR GLASS BLACK. EXTEND WALL IN FRONT OF WINDOW TO DECK ABOVE.
20. INFILL EXISTING WALL TO MAKE FLUSH WITH REMAINING.
21. INSTALL DRAIN CLEANLY AROUND SHEET VINYL. SEE DETAIL 4/66-201. SEE PLUMBING DRAWINGS FOR
EXTENT OF WORK.
22. PROVIDE NEW MAG LOCK POWER SUPPLY AND REQUEST TO EXIT BUTTON. CARD READER BY OWNER.
NEW WORK NOTES
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Date
Project No.Drawing Title
Building No.
Location
Drawn by:Checked by:
Project Title
SHEET OF
Drawing No.APPROVED: PROJECT DIRECTOR www.pfa-architect.com
ARCHITECTURE, PLANNING, INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510
Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
1010 Kings Highway South Building One - 1st Floor Cherry Hill, NJ 08034 Tel (856) 429-4000 Fax (856) 429-5002
F
E
D
C
E
B
A th re e-ei gh th s in ch o ne fo ot on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ha lf in ch on e fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
Building 66
/1
9/
:5 8:
A
M
66-A111
HAMPTON, VIRGINIA
Renovate Administrative Bldg.
jht ljh12-19-2014
590-14-102New Work Plan - First and Second Floor
1/8" = 1'-0"
NEW WORK PLAN - FIRST FLOOR
1/8" = 1'-0"
NEW WORK PLAN - SECOND FLOOR
ROOM LEGEND
NUMBER NAME
100 WAITING AREA
100A CONFERENCE ROOM
100C MECH CLOSET
101 LOBBY
101A FOYER
101B RECEPTION CHECK-IN
101C OFFICE
102 ANTE ROOM
102A OFFICE
102B OFFICE
102C OFFICE
102D CHIEF OFFICE
102E OFFICE
102F OFFICE
102G OFFICE
102H OFFICE
102L MECHANICAL ROOM
103 STAIRWELL
103E JANITOR
103F VESTIBULE
103G MEN'S TOILET
104 ANTI-ROOM CORRIDOR
104A AFGE OFFICE
104B MECHANICAL ROOM
104C NAGE OFFICE
104D NAGE OFFICE
104E NAGE OFFICE
104F AFGE OFFICE
104G STORAGE ROOM
104H AFGE OFFICE
104I AFGE OFFICE
104J AFGE OFFICE
104L OFFICE
104M OFFICE
104N OFFICE
104O OFFICE
104P OFFICE
104Q NAGE OFFICE
105 STAIRWELL
106 DATA CLOSET
107 VESTIBULE
107A WOMEN'S TOILET
108 STAIRWELL
201 VESTIBULE
201A RECEPTION / WAITING
201B FILE ROOM
201C EXAM ROOM
201D OFFICE
202 OFFICE
202B OFFICE
202C OFFICE
202D OFFICE
202E OFFICE
202F OFFICE
202G OFFICE
202H OFFICE
202J MECHANICAL ROOM
203 WOMEN'S RESTROOM
203C JANITOR
203D MEN'S RESTROOM
203E STAIRWELL
204 CUBICALS
204A OFFICE
204B MECHANICAL ROOM
204K SUPERVISOR OFFICE
204Q OFFICE
205 STAIRWELL
208 STAIRWELL
C-1 CORRIDOR
C-2 CORRIDOR
C-3 CORRIDOR
EG-1 ELEVATOR
EG-2 ELEVATOR
NO.
AI
NI
GR
IV
FOHTLAEWNO
M M
O
• ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL
CODES AND ORDINANCES.
• CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF
CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE
ARCHITECT FOR A RESOLUTION.
• EACH SUB CONTRACTOR SHALL REVIEW THE CONSTRUCTION DOCUMENTS AND EVALUATE THE SCOPE OF WORK REQUIRED BY THEIR RESPECTIVE TRADE AND ANY CONFLICTS WITH OTHER TRADES. ANY CONFLICTS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR A RESOLUTION.
• PROVIDE SHALL MEAN TO SUPPLY, TO FURNISH AND TO INSTALL COMPLETE WITH ALL ACCESSORIES, PARTS AND/OR SERVICES TO BE READY FOR ITS INTENDED USE.
• CONTRACTOR SHALL COORDINATE ALL REQUIRED CONDUIT, PIPING AND CHASES FOR OWNER
FURNISHED OWNER INSTALLED EQUIPMENT WITH THE OWNER.
• CONTRACTOR SHALL COORDINATE WITH WORK BEING PERFORMED UNDER SEPARATE CONTRACT BY
OWNER.
• SEE FIRE PLAN FOR FIRE WALL AND SMOKE PARTITION LOCATIONS.
• ALL ABUTTING DISSIMILAR MATERIALS ARE TO BE SEALED. COLOR TO MATCH ADJACENT MATERIALS.
• ALL NOTES, REMARKS AND/OR SCHEDULES ON THIS SHEET ARE FOR THIS SHEET ONLY UNLESS
OTHERWISE NOTED.
• REMOVE ALL EXISTING ACCESSORY / EQUIPMENT ITEMS: SECURITY CAMERAS, WIRELESS CONNECTION BOXES, EMERGENCY LIGHT FIXTURES, WINDOW COVERINGS, CEILING AND WALL MOUNTED SPEAKERS, THERMOSTAT CONTROLS, RAISED OUTETS ON CMU WALLS, PUSH BUTTON CONTROL BOXES, FIRE PULLS AND FIRE EXTINGUISHERS SHALL BE FIELD VERIFIED BY THE CONTRACTOR FOR WORKING CAPACITY, LOCATION AND TYPE. RETAIN ITEMS FOR INSTALLATION IN EXISTING LOCATION UNLESS OTHER WISE NOTED. REPAIR AND REPLACE ITEMS AS NECCESARY; MATCH EXISTING. SEE M.E.P. DRAWINGS FOR
EXTENT OF WORK.
• ALL EXISTING LIGHT FIXTURE AND EXISTING ACCESSORY / EQUIPMENT ITEMS LOCATIONS MUST BE FIELD
VERIFIED BY THE CONTRACTOR DURING BIDDING.
1. REMOVE EXISTING CEILING GRID SYSTEM, ACOUSTIC TILE, AND LIGHT FIXTURES AS REQUIRED TO INSTALL NEW WORK. RETAIN FOR RE-INSTALLATION. REPLACE ALL DAMAGED OR SOILED ACOUSTIC
TILES ; MATCH EXISTING.
2. PROVIDE NEW CEILING GRID SYSTEM, ACOUSTIC TILE [ACT#1]. SEE ELECTRICAL DRAWINGS FOR
EXTENT OF WORK.
3. PROVIDE GYPSUM BOARD SOFFIT AT THIS LOCATION. SEE DETAIL 1/66-A201.
4. CLEAN, REPAIR AND RE-PAINT GYPSUM BOARD CEILING COMPLETE. CEILING HEIGHT VARIES; FIELD
VERIFY.
5. PROVIDE GYPSUM BOARD SOFFIT AT THIS LOCATION. SEE DETAIL 2/66-A201.
6. CLEAN, REPAIR AND RE-PAINT EXPOSED CEILING COMPLETE.
7. REMOVE EXISTING PATIENT CURTAIN TRACK. RETAIN FOR RE-INSTALLATION IN EXISTING LOCATION.
8. REMOVE EXISTING LIGHT FIXTURES, WINDOW COVERINGS, SECURITY CAMERAS, WIRELESS
CONNECTION BOXES, AND EMERGENCY LIGHTING AS NECCESSARY TO COMPLETE NEW WORK. SEE
M.E.P. DRAWINGS FOR EXTENT OF WORK. REPAIR WOODEN PANELING AS NECCESARY; MATCH EXISTNG.
REPLACE ANY ITEMS AS NECCESARY; MATCH EXISTING.
CEILING NOTES
GENERAL CEILING NOTES
2' X 2' RECESSED
LED LIGHT FIXTURE
CEILING LEGEND
EXHAUST AIR DIFFUSER
RETURN AIR DIFFUSER
SUPPLY AIR DIFFUSER
2' X 4 RECESSED
LED LIGHT FIXTURE
EXIT SIGN
SUSPENDED LED STRIP LIGHT
RECESSED LED LINEAR LIGHT
W/ UTILITY MODULES
NOTE: SEE M.E.P. DRAWINGS FOR ADDITIONAL INFORMATION.
DECORATIVE SUSPENDED
GLASS LIGHT FIXTURE
2 3 4 5
6 7
8 9 10 11
B
D
A
C
E
TYP
107A
103G
103F
103E
C-1
6 6
104B102L
1 1 1
1 1 1
TYP
8 1
11 1 1 1
1 1 1
102H102G102F102E102A
102B 102C 102D
100 100A
101C
EG-1
101B
104C 104D 104E 104F
104Q
104P 104O 104N 104M 104L
104J
104I104H
104A
104G
100C
2' - 0" 2' - 0"
TYP
EQ
EQ
EQ EQ
EQ
EQ
EQ EQ
66-A811
TYP.
66-A811
TYP.
TYP
PROJECT LIMITS
1st FLOOR - KEY PLAN
2.1 2.2 2.3
2.A
204B202J
203E
203 203D
205208
202F
202E
202D 202C 202B
201B
202H202G
204A
204Q
204K
2.4
2.B
2.5 2.6
201A
EG-2
201C
TYP
2' - 0"
2' - 0"
6 6
C-3
TYP
TYP
TYP
EQ
EQ
EQ EQ
EQ
EQ
EQEQ
EQ
EQ
66-A811
TYP.
1'
6" 2'
PROJECT LIMITS
2nd FLOOR - KEY PLAN
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Date
Project No.Drawing Title
Building No.
Location
Drawn by:Checked by:
Project Title
SHEET OF
Drawing No.APPROVED: PROJECT DIRECTOR www.pfa-architect.com
ARCHITECTURE, PLANNING, INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510
Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
1010 Kings Highway South Building One - 1st Floor Cherry Hill, NJ 08034 Tel (856) 429-4000 Fax (856) 429-5002
F
E
D
C
E
B
A th re e-ei gh th s in ch o ne fo ot on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ha lf in ch on e fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
Building 66
/1
9/
:5 8:
A
M
66-A200
HAMPTON, VIRGINIA
Renovate Administrative Bldg.
jht ljh12-19-2014
590-14-102Reflected Ceiling Plan - First and Second Floor
1/8" = 1'-0"
REFLECTED CEILING PLAN - FIRST FLOOR
ROOM LEGEND
NUMBER NAME
100 WAITING AREA
100A CONFERENCE ROOM
100C MECH CLOSET
101 LOBBY
101A FOYER
101B RECEPTION CHECK-IN
101C OFFICE
102 ANTE ROOM
102A OFFICE
102B OFFICE
102C OFFICE
102D CHIEF OFFICE
102E OFFICE
102F OFFICE
102G OFFICE
102H OFFICE
102L MECHANICAL ROOM
103 STAIRWELL
103E JANITOR
103F VESTIBULE
103G MEN'S TOILET
104 ANTI-ROOM CORRIDOR
104A AFGE OFFICE
104B MECHANICAL ROOM
104C NAGE OFFICE
104D NAGE OFFICE
104E NAGE OFFICE
104F AFGE OFFICE
104G STORAGE ROOM
104H AFGE OFFICE
104I AFGE OFFICE
104J AFGE OFFICE
104L OFFICE
104M OFFICE
104N OFFICE
104O OFFICE
104P OFFICE
104Q NAGE OFFICE
105 STAIRWELL
106 DATA CLOSET
107 VESTIBULE
107A WOMEN'S TOILET
108 STAIRWELL
201 VESTIBULE
201A RECEPTION / WAITING
201B FILE ROOM
201C EXAM ROOM
201D OFFICE
202 OFFICE
202B OFFICE
202C OFFICE
202D OFFICE
202E OFFICE
202F OFFICE
202G OFFICE
202H OFFICE
202J MECHANICAL ROOM
203 WOMEN'S RESTROOM
203C JANITOR
203D MEN'S RESTROOM
203E STAIRWELL
204 CUBICALS
204A OFFICE
204B MECHANICAL ROOM
204K SUPERVISOR OFFICE
204Q OFFICE
205 STAIRWELL
208 STAIRWELL
C-1 CORRIDOR
C-2 CORRIDOR
C-3 CORRIDOR
EG-1 ELEVATOR
EG-2 ELEVATOR
1/8" = 1'-0"
REFLECTED CEILING PLAN - SECOND FLOOR
NOTE: HALF-TONE GRID INDICATES EXISTING.
NOTE: HALF-TONE GRID INDICATES EXISTING.
NO.
AI
NI
GR
IV
FOHTLAEWNO
M M
O
DOOR
DOOR FRAME AS SCHEDULED
PORCELAIN TILE AS SCHEDULED
FLASH PATCH TRANSITION
METAL DIVIDER EDGE
FLUSH WITH ADJACENT FINISH
CPT AS SCHEDULED
METAL EDGE TRIM [TR #1]
TYPICAL PORCELAIN TILE TO CARPET TRANSITION
2"
3'
0"
3"
4'
2" WT#1, TYP.
WT#2, TYP.
TR#4, TYP.
MT#1, TYP.
CB#1, TYP.
6" 4"
3"
1' - 0"
PAINTED GYP. ABOVE, TYP.
VA
R
IE
S
SV COVE BASE DETAIL
VINYL COVE CAP
WALL AS SCHEDULED
SHEET VINYL RESILIENT
FLOORING TURNED UP
TO FORM BASE
RUBBER FILLET STRIP
SHEET VINYL
RESILIENT FLOORING
FINISH FLOOR
6"
COLORED CAULK TO MATCH SHEET VINYL
2"
3'
0"
3"
4'
2"
4" 6"
1'
0"
VA
R
IE
S
3"
WT#1, TYP.
WT#2, TYP.
TR#4, TYP.
MT#1, TYP.
CB#1, TYP.
WT#3, TYP.
1' - 0"
2' - 0"
TYPICAL LVT / SVT TO CARPET REDUCER
DOOR AS
SCHEDULED
DOOR FRAME
BEYOND
SOLID VINYL TILE
AS SCHEDULED
2 1/2" WHEELED
TRAFFIC REDUCER
[TR#2]
(FIELD VERIFY STYLE)
CARPET AS
SCHEDULED
NOTE: INSTALL T-MOLD REDUCER STRIP
SUCH THAT IT IS CONCEALED FROM VIEW
WHEN DOOR IS IN CLOSED POSITION.
GENERAL FINISH NOTES
• PROVIDE FLOOR TRANSITIONS AS NOTED WHERE ALL FLOOR FINISH CHANGE MATERIALS.
CONTRACTOR TO VERIFY TRANSITION AND REDUCER STYLE PRIOR TO INSTALLATION.
• ALL FLOOR FINISH TRANSITIONS SHALL BE CONCEALED BY A CLOSED DOOR. TRANSITIONS
SHALL CLEAR DOORS IN THE OPEN POSITION.
• ALL FINISHES LISTED ARE NEW UNLESS SPECIFIALLY NOTED AS EXISTING.
• WALL BASE SHALL BE RUBBER ROLL GOODS, UNLESS OTHERWISE NOTED.
• WHERE PAINTED GWB ARE INDICATED, PAINTING INCLUDES ALL PREVIOUSLY PAINTED
SURFACES AND TRIM.
• HATCH PATTERNS ON FINISH PLANS ARE REPRESENTATIONAL ONLY TO DISTINGUISH COLOR
CHANGES, UNLESS OTHERWISE NOTED.
• ALL WALLS TO BE PAINTED PNT #2, EGGSHELL, UNLESS OTHERWISE NOTED. SEE FINISH
COLORS FOR INFORMATION.
• ALL DOORS AND DOOR TRIM TO BE PAINTED PNT #5, SEMI-GLOSS, UNLESS OTHERWISE
NOTED. SEE FINISH COLORS FOR INFORMATION.
• ALL VINYL COMPOSITION TILE TO BE INSTALLED MONOLITHIC.
• ALL CARPET TILE TO BE INSTALLED QUARTER TURNED.
• ALL RUBBER WALL BASE SHALL BE INSTALLED WITH FORMED CORNERS.
• INSTALL [TR#1] (METAL TRANSITION STRIP) WHERE TILE MEETS CARPET TILE. CONTRACTOR
TO VERIFY STYLE PROFILE PRIOR TO INSTALLATION.
• INSTALL [TR#2] (VINYL REDUCER STRIP) WHERE RESILIENT MEETS CARPET TILE. COLOR TO
MATCH RESILIENT MATERIAL.
• REFER TO SHEET 66-A200 FOR CEILING DETAILS.
• SEE NEW WORK NOTES ON SHEET 66-A110 FOR ACCENT PAINT LOCATIONS.
FINISH REMARKS
1. PROVIDE METAL EDGE TRIM [TR#3] AT ALL OUTSIDE EDGES OF TILE WAINSCOTING IN TOILETS.
PROVIDE MATCHING INSIDE / OUTSIDE CORNER PCS.
2. INSTALLED PORCELAIN TILE [WT#1 / WT#2 / WT#3] WITH ALIGNED GROUT JOINTS. USE 3/16"
GROUT JOINT MINIMUM.
3. INSTALL [GRT#1] FOR WALL TILE ; INSTALL [GRT#2] FOR FLOOR TILE.
4. INSTALL TILE PATTERN 1/2" HEIGHT ON ALL WALLS, LESS PLUMBING WALL. SEE DETAIL 5/66- A600.
5. INSTALL TILE PATTERN FULL HEIGHT ON PLUMBING WALL ONLY. SEE DETAIL 6/66-A600.
6. INSTALL [LVT#1] ON DIAGONAL. AT PATTERN EDGE, PROVIDE [LVT#2] FOR LINEAR BANDING.
7. PROVIDE 6" SHEET VINYL INTEGRAL COVE BASE. SEE DETAIL 3/66-A600. PROVIDE HEAT
WELDED SEAMS WITH WELDING ROD COLOR TO MATCH ADJACENT FIELD COLOR OF SHEET VINYL
AS NOTED.
8. INSTALL [MB#1] MILLWORK BASE AND [QR#1] QUARTER ROUND AT THIS LOCATION. MITER ALL
CORNER CLEANLY AND PROVIDE CUSTOM COLOR MATCHED CAULK FOR ALL CUT / EXPOSED
EDGES.
9. PROVIDE PAINT [PNT#6] FOR STAIR RAILINGS AND HAND RAILS.
10. PROVIDE [CG#1] CORNER GUARD ALL OUTSIDE CORNER LOCATIONS.
11. PROVIDE [CG#2] CUSTOM WIDTH, FLUSH MOUNT CORNER GUARD AT LAVATORY WALL. SEE
DETAIL 4/66-A600. FINISH TO JOIN CLEANLY TO EDGES. PROVIDE CUSTOM COLOR MATCHED
CAULK ALONG JOINTS.
12. PROVIDE ACCENT PAINT [ PNT#5] AT ALL FULL AND RECESSED COLUMN LOCATIONS. SEE
FINISH SCHEDULE FOR DETAILS.
FINISH COLORS
FLOOR
SV#1: (JANITOR) SPECKLED TAN
CPT#1 (FIELD) SAGE / TAN / PURPLE MULTI-TONE BLOCK PRINT
LVT#1 (NATURAL STONE) TAUPE TRAVERTINE, 18" X 18"
LVT#2 (NATURAL STONE) TAUPE TRAVERTINE, 4" X 36"
SVT#1 (MECHANICAL) DARK GRAY - MARBELIZED
RST#1: (STAIR TREAD) HEAVY DUTY RUBBER; SQUARE NOSE TREAD WITH
ABRASIVE STRIP [COLOR: “SAFETY YELLOW”]; RAISED SQUARE TREAD
TEXTURE; COLOR: MEDIUM TAUPE WITH MIN. 10% RECYLED CORK
CONTENT.
RT#1: (STAIR LANDING) RUBBER TILE; RAISED CIRCULAR DESIGN;
COLOR: DARK BLUE / GRAY WITH MIN. 10% RECYLED CORK CONTENT.
PT#1: (MOSAIC FLOOR TILE) 3" SLATE; BLUE / GRAY WITH PURPLE FLECKS
TR#1: (METAL TRANSITION STRIP) SATIN ANNODIZED ALUMINUM
TR#2: (VINYL REDUCER STRIP) 2 1/2" WHEELED TRAFFIC
TRANSITION
WALL AND CEILING
ACT#1 (STANDARD) ANGLED TEGULAR; WHITE
WT#1: (WALL TILE) UNPOLISHED; BEIGE; 6" X 12"
WT#2: (WALL TILE) UNPOLISHED; BEIGE; 3" X 24"
WT#3: (WALL TILE) UNPOLISHED; BEIGE; 12" X 24"
MT#1: (MOSAIC TILE) 5/8" X 5/8" SQUARE MOSAIC; MIXED TUMBLED STONE /
GLASS
CB#1: (COVE BASE) UNPOLISHED; BEIGE; 2" X 12"; PROVIDE MATCHING INSIDE
AND OUTSIDE CORNERS.
CB#2 (BULLNOSE TRIM) UNPOLISHED; BEIGE; 4" X 12"BN
CG#1 (CORNER GUARD) 3 1/2" STAINLESS STEEL WITH #4 SATIN FINISH;
SURFACE MOUNTED.
CG#2 (CORNER GUARD) CUSTOM WIDTH FLUSH MOUNT CORNER GUARD;
COLOR: FAWN
PNT#1 (CEILINGS) OFF-WHITE
PNT#2 (CREAM) CREAM
PNT#3 (BEIGE) YELLOW TONED BEIGE
PNT#4 (CELERY) LIGHT SAGE
PNT#5 (COLUMN ACCENT) MEDIUM SAGE
PNT#6 (STAIR-RAILS / DOOR-FRAMES) MEDIUM GRAY
PNT#7 (TAUPE) RED TONED BEIGE
RB#1 (RUBBER WALL BASE) 6" THERMOSET RUBBER WALL BASE; 1/8" THICK; TOE;
COLOR: FAWN
MB#1 (PROFILED BASE) 6" MILLWORK RESILIENT WALL BASE; COLOR: FAWN;
MITER CORNERS. CAULK ALL CUT / EXPOSED EDGES WITH CUSTOM
COLOR MATCHED CAULK.
QR#1 (QUARTER ROUND) 1/2" X 1/2" HIGH RADIUS WITH ADHESIVE BACKING
TO MATCH MILLWOR BASE. PROVIDE ADDITIONAL ADHESIVE TO
SECURE FIRMLY ALONG ALL MILLWORK BASE. CAULK ALL CUT /
EXPOSED EDGES WITH CUSTOM COLOR MATCHED CAULK.
(FIELD VERIFY)
TR#3: (METAL EDGE TRIM) SATIN ANNODIZED NICKEL; EXTRUDED SQUARE
PROFILE; PROVIDE MATCHING INSIDE AND OUTSIDE CORNERS.
TR#4: (DECORATIVE METAL TRIM LINER) SATIN ANNODIZED NICKEL;
[1" wide X 1/4" thick]
TR#5: (METAL EDGE TRIM) SATIN ANNODIZED NICKEL; LINEAR PROFILE;
PROVIDE MATCHING INSIDE AND OUTSIDE CORNERS.
CASEWORK
SS#1: (LAVATORY COUNTERTOP) QUARTZ: BLACK BASE WITH PEARL CHIPS
SS#2: (WINDOW SILLS) SOLID SURFACE: CREAM WITH BEIGE FLECKS
ACCESSORIES
GRT#1: (WALL GROUT) PREMIUM EPOXY GROUT; MEDIUM BEIGE
GRT#2: (FLOOR GROUT) PREMIUM EPOXY GROUT; DARK GREY
TP#1: (TOILET PARTITION) ROTARY BRUSHED; METALLIC NICKEL
FINISHED WALL WIDTH
5 /8"
GWB
1 5/8"
EX
TR
U D
ED
P
LA
ST
IC
C
O
VE
R
3/4" FOAM TAPE
ALUMINUM RETAINER
#6 X 1 15/8"
BUGLE HG SMS
METAL STUD
D R
Y W
A
LL
S
ET
BA
C
K
FEATHER WALL FINISH
TO TAPER INTO ADJACENT
FINISH; PROVIDE COLOR MATCHED CAULK AT
EXPOSED GAPS.
[CG#2] CORNER GUARD
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Date
Project No.Drawing Title
Building No.
Location
Drawn by:Checked by:
Project Title
SHEET OF
Drawing No.APPROVED: PROJECT DIRECTOR www.pfa-architect.com
ARCHITECTURE, PLANNING, INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510
Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
1010 Kings Highway South Building One - 1st Floor Cherry Hill, NJ 08034 Tel (856) 429-4000 Fax (856) 429-5002
F
E
D
C
E
B
A th re e-ei gh th s in ch o ne fo ot on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ha lf in ch on e fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
Building 66
/1
9/
:5 8:
A
M
66-A600
HAMPTON, VIRGINIA
Renovate Administrative Bldg.
jht ljh12-19-2014
590-14-102Finish Schedule, Details and Notes
FINISH SCHEDULE
NUMBER Name
FLOOR
Floor Color
BASE
Base Color
WALL
Wall Color CEILING Ceiling
Color Height REMARKSMTL MTL MTL MTL
100 WAITING AREA CPT CPT#1 MB / QR MB#1 / QR#1 PTD GWB PNT#2 ACT ACT#1 TME 8,10
100A CONFERENCE ROOM EXIST ETR EXIST TME PTD GWB ETR EXIST ETR EXIST -
100C MECH CLOSET EXIST ETR EXIST TME PTD GWB ETR EXIST ETR EXIST -
101 LOBBY CPT CPT#1 MB / QR MB#1 / QR#1 PTD GWB PNT#2 / PNT#5 EXIST ETR TME 8,10,12
101A FOYER CPT CPT#1 MB / QR MB#1 / QR#1 PTD GWB PNT#2 EXIST ETR TME 8,10
101B RECEPTION CHECK-IN EXIST ETR EXIST TME PTD GWB ETR EXIST ETR TME -
101C OFFICE EXIST ETR EXIST TME PTD GWB ETR EXIST ETR TME -
102 ANTE ROOM EXIST ETR EXIST TME PTD GWB ETR EXIST ETR TME -
102A OFFICE EXIST ETR EXIST TME PTD GWB ETR EXIST ETR TME -
102B OFFICE EXIST ETR EXIST TME PTD GWB ETR EXIST ETR TME -
102C OFFICE EXIST ETR EXIST TME PTD GWB ETR EXIST ETR TME -
102D CHIEF OFFICE EXIST ETR EXIST TME PTD GWB ETR EXIST ETR TME -
102E OFFICE EXIST ETR EXIST TME PTD GWB / CMU ETR EXIST ETR TME -
102F OFFICE EXIST ETR EXIST TME PTD GWB / CMU ETR EXIST ETR TME -
102G OFFICE EXIST ETR EXIST TME PTD GWB / CMU ETR EXIST ETR TME -
102H OFFICE EXIST ETR EXIST TME PTD GWB / CMU ETR EXIST ETR TME -
102L MECHANICAL ROOM SVT SVT#1 RB RB#1 PTD GWB / CMU PNT#3 EXP - - -
103 STAIRWELL RST / RT RST#1 / RT#1 RB RB#1 PTD GWB / CMU PNT#3 PTD GWB - VARIES 9,10
103E JANITOR SV SV#1 SV SV#1 EPOXY PTD GWB/CMU PNT#2 ACT ACT#1 9'-0" 7
103F VESTIBULE LVT LVT#1 MB / QR MB#1 / QR#1 PTD GWB PNT#2 ACT ACT#1 TME 6, 8, 10 103G MEN'S TOILET PT PT#1 CB / BN CB#1 / BN#1 WT / MT / TR / MR GWB WT#1,2,3 / MT#1 / TR#4 / TR#5 / PNT#7 ACT / PTD GWB ACT#1 / PNT#1 VARIES 1,2,3,4, 5, 11 104 ANTI-ROOM CORRIDOR CPT CPT#1 RB RB#1 PTD GWB PNT#4 / PNT#5 EXIST ETR EXIST 10,12
104A AFGE OFFICE CPT CPT#1 RB RB#1 PTD GWB PNT#2 EXIST ETR TME 10
104B MECHANICAL ROOM SVT SVT#1 RB RB#1 PTD GWB / CMU PNT#3 EXP - - -
104C NAGE OFFICE CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 EXIST ETR TME 10,12
104D NAGE OFFICE CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 EXIST ETR TME 10,12
104E NAGE OFFICE CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 EXIST ETR TME 10,12
104F AFGE OFFICE CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 EXIST ETR TME 10,12
104G STORAGE ROOM CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 EXIST ETR TME 10
104H AFGE OFFICE CPT CPT#1 RB RB#1 PTD GWB PNT#2 EXIST ETR TME 10,12
104I AFGE OFFICE CPT CPT#1 RB RB#1 PTD GWB PNT#2 EXIST ETR TME 10,12
104J AFGE OFFICE CPT CPT#1 RB RB#1 PTD GWB PNT#2 EXIST ETR TME 10
104L OFFICE CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 EXIST ETR TME 10
104M OFFICE CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 EXIST ETR TME 10
104N OFFICE CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 EXIST ETR TME 10
104O OFFICE CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 EXIST ETR TME 10
104P OFFICE CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 EXIST ETR TME 10
104Q NAGE OFFICE CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 EXIST ETR TME 10
105 STAIRWELL RST / RT RST#1 / RT#1 RB RB#1 PTD GWB / CMU PNT#3 PTD GWB - VARIES 9,10
106 DATA CLOSET EXIST ETR EXIST TME PTD GWB ETR EXIST ETR EXIST -
107 VESTIBULE LVT LVT#1 RB RB#1 PTD GWB PNT#2 ACT ACT#1 TME 6, 8, 10
107A WOMEN'S TOILET PT PT#1 CB / BN CB#1 / BN#1 WT / MT / TR / MR GWB WT#1,2,3 / MT#1 / TR#4 / TR#5 / PNT#7 ACT / PTD GWB ACT#1 / PNT#1 VARIES 1,2,3,4, 5, 11 108 STAIRWELL RST / RT RST#1 / RT#1 RB RB#1 PTD GWB / CMU PNT#3 PTD GWB - VARIES 9,10 201 VESTIBULE CPT CPT#1 MB / QR MB#1 / QR#1 PTD GWB / CMU PNT#2 EXIST ETR EXIST 8,10
201A RECEPTION / WAITING EXIST ETR EXIST TME PTD GWB / CMU ETR EXP ETR EXIST -
201B FILE ROOM EXIST ETR EXIST TME PTD GWB ETR EXIST ETR EXIST -
201C EXAM ROOM EXIST ETR EXIST TME PTD GWB / CMU ETR EXIST ETR EXIST -
201D OFFICE EXIST ETR EXIST TME PTD GWB / CMU ETR EXIST ETR EXIST 8,10
202 OFFICE CPT CPT#1 RB RB#1 PTD GWB PNT#4 / PNT#5 EXIST ETR EXIST 12
202B OFFICE CPT CPT#1 RB RB#1 PTD GWB PNT#2 EXIST ETR EXIST 8,10
202C OFFICE CPT CPT#1 RB RB#1 PTD GWB PNT#2 EXIST ETR EXIST 8,10
202D OFFICE CPT CPT#1 RB RB#1 PTD GWB PNT#2 EXIST ETR EXIST 8,10
202E OFFICE CPT CPT#1 RB RB#1 PTD GWB PNT#2 EXIST ETR EXIST 8,10
202F OFFICE CPT CPT#1 RB RB#1 PTD GWB PNT#2 EXIST ETR EXIST 8,10
202G OFFICE CPT CPT#1 RB RB#1 PTD GWB PNT#2 EXIST ETR EXIST 8,10
202H OFFICE CPT CPT#1 RB RB#1 PTD GWB PNT#2 EXIST ETR EXIST 8,10
202J MECHANICAL ROOM SVT SVT#1 RB RB#1 PTD GWB / CMU PNT#3 EXP - TME -
203 WOMEN'S RESTROOM PT PT#1 CB / BN CB#1 / BN#1 WT / MT / TR / MR GWB WT#1,2,3 / MT#1 / TR#4 / TR#5 / PNT#7 ACT / PTD GWB ACT#1 / PNT#1 VARIES 1,2,3,4, 5, 11
203C JANITOR SV SV#1 SV SV#1 EPOXY PTD GWB/CMU PNT#2 ACT ACT#1 9'-0" 7
203D MEN'S RESTROOM PT PT#1 CB / BN CB#1 / BN#1 WT / MT / TR / MR GWB WT#1,2,3 / MT#1 / TR#4 / TR#5 / PNT#7 ACT / PTD GWB ACT#1 / PNT#1 VARIES 1,2,3,4, 5, 11 203E STAIRWELL RST / RT RST#1 / RT#1 RB RB#1 PTD GWB / CMU PNT#3 PTD GWB - VARIES 9,10
204 CUBICALS CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#4 / PNT#5 ACT ACT#1 TME 12
204A OFFICE CPT CPT#1 RB RB#1 PTD GWB PNT#2 ACT ACT#1 TME -
204B MECHANICAL ROOM SVT SVT#1 RB RB#1 PTD GWB / CMU PNT#3 EXP - TME -
204K SUPERVISOR OFFICE CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 ACT ACT#1 TME 10
204Q OFFICE CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 ACT ACT#1 TME 10
205 STAIRWELL RST / RT RST#1 / RT#1 RB RB#1 PTD GWB / CMU PNT#3 PTD GWB - VARIES 9,10 208 STAIRWELL RST / RT RST#1 / RT#1 RB RB#1 PTD GWB / CMU PNT#3 PTD GWB - VARIES 9,10 C-1 CORRIDOR CPT / LVT CPT#1 / LVT#1 MB / QR MB#1 / QR#1 PTD GWB / CMU PNT#2 ACT / PTD GWB ACT#1 / PNT#1 TME 8,10
C-2 CORRIDOR CPT CPT#1 RB RB#1 PTD GWB / CMU PNT#2 ACT ACT#1 TME 10,12
C-3 CORRIDOR CPT / SVT CPT#1 / LVT#1 MB / QR MB#1 / QR#1 PTD GWB / CMU PNT#2 ACT / PTD GWB ACT#1 / PNT#1 TME 8,10
EG-1 ELEVATOR EXIST ETR EXIST TME - PNT#2 MFTR STD ETR TME -
EG-2 ELEVATOR EXIST ETR EXIST TME - PNT#2 MFTR STD ETR TME -
66-A600 1 1/2" = 1'-0"
1 THRESHOLD DETAIL
66-A600 1/2" = 1'-0"
5 TYPICAL TILE PATTERN - 1/2 HEIGHT
66-A600 3" = 1'-0"
3 SV DETAIL
66-A600 1/2" = 1'-0"
6 TYPICAL TILE PATTERN - FULL HEIGHT
66-A600 1 1/2" = 1'-0"
2 TRANSITION DETAIL
NTS66-A600
4 FLUSH MOUNT CORNER GUARD - FULL HEIGHT
NO.
AI
NI
GR
IV
FOHTLAEWNO
M M
O
66-A810
66-A810
6' - 0 1/2"
5' - 0 1/2"
TP1
TP1 TP1
GB3
GB2
GB2
GB3
GB1
GB2
GB1
GB2
6" 6"
PTR1PTR1
MR1
M1B M1B
M1B
M3
M1B
M3
M3
M3
TP1
GB2
GB2
TP1 GB2
M1B M1B
M1B
M1B
M1B
M1B
M1B M1B
M1BM1B
M1B
M1B
M1B
M1B
M3B M3B 6' - 0 1/2"
STAIRWELL
CORRIDOR
C-1
VESTIBULE
VESTIBULE
103F
JANITOR
103E
MEN'S TOILET
103G
WOMEN'S TOILET
107A
1'
/8
2'
5'
6" 1'
6"
M6
1'
/8
2'
5'
6" 1'
6"
4' - 6"
5'
7/
8" 4'
1/ 2"
5'
7/
8"
/4
5'
7/
8"
/4
37' - 11 3/8"
M1B
M3B
MR1
5' - 0 1/2"
11' - 6" 11' - 6"
PIPING
M1B
HD1 HD1
SD1
SD1
3'
1/
2" 2'
5'
1/ 2"
2'
6" 2'
6"
2'
6" 2'
6"
SD1
SD1
MR1
MR1
LVTY1 LVTY1
SN1
SN1
SN1
HD1 HD1
RH1
RH1
RH1
RH1
RH1
GB2
FA
C
E O
F
FI
N
IS
H
5'
1/
2" 2'
FA
C
E O
F
FI
N
IS
H
3'
1/
2"
5'
2"
3' - 8 7/8"
5'
3/
4"
4'
1/
2" 5'
2"
1 FA
C
E O
F
FI
N
IS
H
FA
C E
O F
FI
N
IS
H
FA
C
E O
F
FI
N
IS
H
FA
C E
O F
FI
N
IS
H
FACE OF FINISH
5' - 2 1/8"
66-A810
66-A811
6' - 0 1/2"
TP1
TP1
TP1
1"
TP1
1"
TP1
6"
GB2
GB1
GB3 GB2
GB1
GB3
GB2
GB2
GB2
GB2
6"
GB2
GB2
MR1
M1B M3
M6 M1B
M1B
M1B
M1B
PTR1 PTR1
1' - 10 3/4"
M1B
M1B
M1B
M1B
M1B
M3B
M1B
M1B
M1B
M3B
M1B
STAIRWELL
203E
CORRIDOR
C-3
MEN'S
RESTROOM
203D
WOMEN'S
RESTROOM
1'
6"
5' - 0 1/2"
5'
7" 2'
5'
7" 3'
1"
3'
1"
5'
/1 6"
5'
1/
4"
/8
MR1
6'
1/
4"
M1B
M1B
M1B
M1B
M3
M3
M1B
3' - 1 1/2"
5' - 6 3/8"
5'
9/
JANITOR
203C
/2
5'
1/
2" 2'
3'
1/ 2"
M3
SD1
SD1
SD1
SD1
HD1
HD1
MR1
LVTY1
LVTY1
SN1
SN1
SN1
HD1
2'
6" 2'
6"
2'
6" 2'
6"
MR1
3'
1" 3'
1"
5'
1/
2" 3'
1/ 8"
/4
RH1
RH1
RH1
M1B
FA
C
E O
F
FI
N
IS
H
FA
C
E O
F
FI
N
IS
H
FA
C
E O
F
FI
N
IS
H
1'
6"
FA
C
E O
F
FI
N
IS
H
5' - 3 3/8" M3
4' - 2 3/4"
M3
M1B
6' - 7 5/16"
PROJECT LIMITS
1st FLOOR - KEY PLAN
PROJECT LIMITS
2nd FLOOR - KEY PLAN
1. HOLD WALL AS TIGHT TO PIPING AS POSSIBLE.
REMARKS
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Date
Project No.Drawing Title
Building No.
Location
Drawn by:Checked by:
Project Title
SHEET OF
Drawing No.APPROVED: PROJECT DIRECTOR www.pfa-architect.com
ARCHITECTURE, PLANNING, INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510
Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
1010 Kings Highway South Building One - 1st Floor Cherry Hill, NJ 08034 Tel (856) 429-4000 Fax (856) 429-5002
F
E
D
C
E
B
A th re e-ei gh th s in ch o ne fo ot on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ha lf in ch on e fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
Building 66
/1
9/
:5 8:
A
M
66-A700
HAMPTON, VIRGINIA
Renovate Administrative Bldg.
jht ljh12-19-2014
590-14-102Enlarged Floor Plans
1/4" = 1'-0"
ENLARGED PLAN - FIRST FLOOR
1/4" = 1'-0"
ENLARGED PLAN - SECOND FLOOR
TOILET ACCESSORY SCHEDULE
MARK DESCRIPTION MOUNTING HEIGHT REMARKS
GB1 36" HORIZONTAL GRAB BAR 34" TO BOTTOM A.F.F.; 6" FROM WALL CFCI
GB2 42" HORIZONTAL GRAB BAR 34" TO BOTTOM A.F.F.; 12" FROM WALL CFCI
GB3 18" VERTICAL GRAB BAR 40" A.F.F. TO TOP OF GRAB BAR; 40" FROM WALL VERTICAL MOUNT HD1 AUTOMATIC HAND DRYER 42" A.F.F TO TOP; 42" FROM WALL; 24"-42" TO CENTERLINE OF ADJACENT FIXTURE CFCI
LVTY1 PREMOLDED QUARTZ LAVATORY UNIT 33.5" TO COUNTER BASIN A.F.F; 60" WIDE CFCI
MR1 CHANNEL FRAMED MIRROR / SHELF COMBINATION 40" TO SHELF BOTTOM A.F.F.; 36" HIGH; EQUAL SPACING ON ALL SIDES CFCI; (1) UNIT OVER EACH FAUCET PTR1 SEMI-RECESSED CONVERTIBLE PAPER TOWEL DISPSENSER / WASTE RECEPTACLE 34" TO TOP OF OPENING; 18" FROM WALL EDGE; CFCI; PROVIDE TRASH LINER INSERT ADD-ON TO UNIT
RH1 CLOTHES HOOK WITH BUMPER 40" A.F.F. TO CENTERLINE OF DOOR. CFCI
SD1 SURFACE MOUNTED SOAP DISPENSER 40" TO CONTROLS A.F.F.; 11.25"" TO CENTERLINE OF SINK OFOI SN1 SURFACE MOUNTED SANITARY NAPKIN DISPSENSER 30" A.F.F. TO TOP OF CABINET; 30" TO CENTERLINE; CFCI;
TP1 TOILET PAPER DISPENSER 19" A.F.F.; 19" TO CENTERLINE OFOI; DOUBLE ROLL UNIT
WALL TYPE SCHEDULE
TYPE STC DESCRIPTION FIRE RATING UL REMARKS
M1B N/A 1 5/8" METAL STUDS AT 16" O.C. MAX. 5/8" GWB ONE SIDE. EXTEND
GWB 4" ABOVE CEILING. FASTEN STUD TO UNDERSIDE OF DECK.
- - AT EXTERIOR WALLS, SEE
NOTE #9 ON SHEET 66-A111
M3 N/A 3 5/8" METAL STUDS AT 16" O.C. MAX. 5/8" GWB BOTH SIDES.
EXTEND GWB TO 4" ABOVE FINISHED CEILING. ANCHOR STUDS TO
UNDERSIDE OF DECK OR STRUCTURE ABOVE AT 48" O.C. MAX
M3B N/A 3 5/8" METAL STUDS AT 16" O.C. MAX. 5/8" GWB ONE SIDE. EXTEND
WALL ASSEMBLY TO 4" ABOVE FINISHED CEILING.
M6 N/A 6" METAL STUDS AT 16" O.C. MAX. 5/8" GWB BOTH SIDES. EXTEND
GWB TO 4" ABOVE FINISHED CEILING. ANCHOR STUDS TO
UNDERSIDE OF DECK OR STRUCTURE ABOVE AT 48" O.C. MAX
NO.
AI
NI
GR
IV
FOHTLAEWNO
M M
O
HMV
HOLLOW METAL VISION
F
FLUSH WOOD
SC
H
ED
U
LE
D
H
EI
G H
T
SCHEDULED WIDTH
VISION
PANEL
SC
H
ED
U
LE
D
H
EI
G H
T
SCHEDULED WIDTH
SC
H
ED
U
LE
D
H
EI
G H
T
SCHEDULED WIDTH
HMPD
HOLLOW METAL
2" 2"VARIES
2"
VA
R
IE
S
2 3/4" 2 3/4"FIELD VERIFY
1'
0"
VA
R
IE
S
3'
3/
4"
3'
- 0
1. EXISTING FRAME TO REMAIN. FIELD VERIFY PRIOR TO ORDERING DOOR.
2. REMOVE EXISTING WOOD WITHIN HEADER. PROVIDE TEMPERED WINDOW
GLAZING TO FIT WITHIN EXISTING FRAME. REMOVED EXISTING DOOR. FIELD
VERIFY. PROVIDE NEW DOOR AND HARDWARE.
3. EXISTING DOOR AND FRAME TO REMAIN. REMOVE EXISTING HARDWARE AND
RETURN TO OWNER. INSTALL NEW HARDWARE. REPAIR DOOR AS
NECCESARY.
4. REMOVED EXISTING DOOR, FRAME AND HARDWARE; RETURN TO OWNER.
PROVIDE NEW DOOR, FRAME AND HARDWARE.
5. PROVIDE NEW DOOR, FRAME AND HARDWARE.
6. PROVIDE DOOR HARDWARE AT THIS LOCATION AS AN ADDITIVE BID ITEM.
CONTRACTOR TO FIELD VERIFY.
DOOR REMARKS
2"
1/2"
HOLLOW METAL
FRAME, (PTD)
CAULK BOTH SIDES (TYP)
METAL STUDS
SEE WALL TYPES
SEE WALL TYPE
PROVIDE MINIMUM OF 3
JAMB ANCHORS PER JAMB
GWB - SEE WALL TYPE
SCHEDULE
FRAME BEYOND
ALUMINUM THRESHOLD SET IN
3 BEADS CONT. SEALANT
PREMOLDED EXPANSION JOINT
EXIST CONCRETE SLAB
7 3/4" 2 3/4"
EXISTING WALL
CAULK
WOOD BRICK MOULD
HOLLOW METAL FRAME
PTD WHITE
1" INSULATED GLASS
ARCHED
1/ 2"
2"
APPLIED METAL STOP
AL
IG
N W
IT
H
B
LD
B
AN
D
DOOR
2 3/4"
EXISTING WALL
CAULK
WOOD BRICK MOULD
PTD WHITE
HOLLOW METAL FRAME
PTD WHITE
1/ 2"
2"
JAMB ANCHOR PROVIDE 4
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Date
Project No.Drawing Title
Building No.
Location
Drawn by:Checked by:
Project Title
SHEET OF
Drawing No.APPROVED: PROJECT DIRECTOR www.pfa-architect.com
ARCHITECTURE, PLANNING, INTERIORS
World Trade Center 101 West Main Street, Suite 7000 Norfolk, VA 23510
Phone: 757-471-0537 Fax: 757-471-4205
PF&A DESIGN
1010 Kings Highway South Building One - 1st Floor Cherry Hill, NJ 08034 Tel (856) 429-4000 Fax (856) 429-5002
F
E
D
C
E
B
A th re e-ei gh th s in ch o ne fo ot on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot on e-ha lf in ch on e fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
Building 66
/1
9/
:5 8:
A
M
66-A800
HAMPTON, VIRGINIA
Renovate Administrative Bldg.
jht…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.