This Sources Sought Notice is issued by the Department of Veterans Affairs (VA) VISN 5 Network Contracting Office for Endodry Cabinets at the Beckley VA Medical Center. The solicitation (Number 36C24525Q0561) seeks potential sources for medical equipment, specifically Medivator Scope Drying Cabinets, with a response deadline of June 18, 2025, at 10:00 AM EST. The procurement includes five line items: two Endodry Advanced Cabinets, two Total Care Connect Endodry units, two installation business days, nine hook-up assemblies, and three Cleanascope Advanced 6-Tray units.

The Statement of Work details that the Beckley VA Medical Center needs to replace end-of-life scope drying cabinets due to age and equipment breakdowns. The required Medivator EndoDry Cabinet offers comprehensive features, including complete endoscope channel drying within one hour, double HEPA filtration, 31-day storage without microbial growth, barcode scanning, touch screen display, and integration with existing Medivator systems. The cabinet is designed to minimize Hospital Acquired Infections (HAI) and reduce endoscope repair costs through hands-free transfers and advanced drying technology. The solicitation uses NAICS code 339113 and is currently in a sources sought notice phase, which means it is not yet a formal solicitation but is gathering market research.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
Endodry Cabinets RFI

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
20422
SOLICITATION NUMBER*
36C24525Q0561
RESPONSE DATE/TIME/ZONE
06-18-2025 10:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
90 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
339113
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

VA Central Office

811 Vermont Ave Washington DC 20420

POINT OF CONTACT*

Contract Specialist Michael Jones michael.jones16@va.gov

PLACE OF PERFORMANCE

ADDRESS
Department of Veterans Affairs

Beckley VA Medical Center

200 Veterans Ave

Beckley WV

POSTAL CODE
25801
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

Responses must be received no later than Wednesday, June 18, 2025, at 10:00AM EST.

THIS SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.

THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS SOURCES SOUGHT NOTICE IN ACCORDANCE WITH (IAW) FAR 15.201(e).

DISCLAIMER: This Sources Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought Notice that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought Notice.

SOURCES SOUGHT DESCRIPTION

This is NOT a solicitation announcement. This is a sources sought notice only. The purpose of this sources sought notice is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339113. Responses to this sources sought notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought notice, a solicitation announcement may be published. Responses to this sources sought notice are not considered adequate responses for a solicitation announcement.

The Department of Veterans Affairs (VA), VISN 5 Network Contracting Office, is seeking sources that can provide Endodry Cabinets for the Beckley VA Medical Center.

ITEM INFORMATION

ITEM NUMBER
DESCRIPTION OF SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
2.00
EA
__________________
__________________

#1 DRY1001 Endodry Adv Cabinet

LOCAL STOCK NUMBER: DRY1001

2.00
EA
__________________
__________________

#2 SE2000452 Total Care Connect Endodry

LOCAL STOCK NUMBER: SE2000452

2.00
EA
__________________
__________________

#3 NS1011 Install, Endodry Business Day

LOCAL STOCK NUMBER: INS1011

9.00
EA
__________________
__________________

#4 28611 Model 2-8-611 Assy, Hook-Up, Oly

LOCAL STOCK NUMBER: 28611

3.00
EA
__________________
__________________

#5 103466 GTIN: 18011517103466 Cleanascope Adv 6 Tray

LOCAL STOCK NUMBER: 103466

GRAND TOTAL
__________________

STATEMENT OF WORK

GENERAL INFORMATION

1. Title: MEDIVATOR SCOPE DRYING CABINETS

2. Scope of work: VAMC Beckley SPS department has been affected by end of life for our Scope drying cabinet and needs to be replaced due to age and the resulting down time due to break downs. Endodry system will circulate better than HEPA filtered air through both the channels of the endoscopes as well as around the exterior of the scope ensuring it is “bone dry” within 1 hour.

This cabinet filters air down to .01 micron. This cabinet is the only cabinet on the market that has the validation for 100% “bone dry” internal channels as well as data that supports a 31-day storage time with no microbial growth. This cabinet is able to track storage times. This cabinet will utilize the same transport cassettes and hookup blocks as the Advantage Plus, thus providing superior efficiency. The hookup blocks are HLD’d every single scope.

This cabinet in conjunction with the cassette system has been proven to reduce endoscope repair damages due to its “hands free” scope transfers. Medivator Endo Dry scope storage cabinet is part of the Medivator scope processing system we use at Beckley VAMC is compatible with our current Medivators and the New Pass-thru medivators.

Design considerations for new equipment:

MEDIVATORS ENDODRY DRYING AND STORAGE CABINET

SALIENT CHARACTERISTICS

(A) Functions to be performed:

The MEDIVATORS® EndoDry Drying & Storage Cabinet provides complete drying of internal endoscope channels within one hour and maintains the microbiological attitude of the high-level disinfected endoscope in a controlled storage environment for up to 31 days. The EndoDry uses instrument grade air flow and double HEPA filtration to dry endoscope channels, which minimizes the risk of bacterial growth that can lead to Hospital Acquired Infections (HAI)

(B) Performance required:

Small footprint and can completely dry endoscope channels within one hour Barcode scanning for endoscope and operator identification Utilizes the Advantage Plus Connection Block for quick-connect from the Advantage to EndoDry Tracks, monitors and logs all aspects of the drying and storage cycle for all endoscopes Color touch screen display for quick identification of endoscope drying status and storage time Rigid plastic cassette allows for no touch transfer of endoscopes from Advantage to EndoDry which protects the endoscope and greatly reduces repair costs Locking door(s) protect endoscope inventory Integrates with the Advantage Plus®, Cleanascope® Advantage and Canexis® Assurance system Available in left or right door swing configurations as well as a pass-thru cabinet option

(C) Essential physical characteristics; Dimensions (if applicable):

ENDODRY™ Cabinet for ADVANTAGE PLUS™ Endoscope Reprocessor requires air supply of 58-145 psi (4-10 bar).

Air supply provides a flow rate of 4.2 scfm (120 l/min ANR) for the Advantage Air supply maximum particle size is <1-micron, maximum dew point is -40°C, maximum oil content is 0.01 mg/m3.

Air Supply plumbed to the wall a minimum of 78.7 inches (200 cm) off the floor above the cabinet.

GFI/RCD protected outlet located on the wall a minimum of 78.7 inches (200 cm) off the floor above the cabinet.

RJ45 wall mounted network jack located on the wall a minimum of 78.7 inches (200 cm) off the floor above the cabinet (ENDODRY™ Cabinet for ADVANTAGE PLUS™ Endoscope Reprocessor only).

Installation site has a level floor.

Installation site accommodates the dimensions of H74.8” x W23.6” x D21.3” (190cm x 60cm x 54cm)

Product Description:

General Air Connection Dimensions: H74.8” X W23.6” X D21.3” Quality: ISO 8573-1:2010 class 1.4.1 (H190 cm x W60 cm x D54 cm) Maximum particle size is 1 micron Maximum dew point is +3°C Maximum oil content is 0.01 mg/m3 Weight: 375 lbs. (170 kg) Pressure: ADV Cabinet: 29-145 psi (2-10 bar) DSD Cabinet: 72-145 psi (5-10 bar) Operating Temperature: 50 -104ºF (10-40ºC) Demand: ADV Cabinet: 3.4 scfm (95 l/min ANR) DSD Cabinet: 7 scfm (200 l/min ANR) Connection: 1/4” (6 mm) ID air hose Electrical Connection Interface Power Supply: 100-240 VAC, 50/60 Hz Ethernet: RJ45, 10/100 Mbit 15A circuit (120v), 20A circuit (230v) Power Input: 75 W

ENDODRY™ Drying and Storage System

The ENDODRY™ Cabinet is a pass-through, hands-free system that uses instrument-grade air for direct channel drying.

Features

· Eight endoscope trays with interlocks

· Barcode reader for consistent data entry, endoscope tracking and user authorization

· Programmable maximum storage time

· Alarm in case of pressure or power loss

· Internal digital documentation of process parameters

· Integrated multi-lingual information and control panel

· CANEXIS™ Software network-compatible

· Available in single-sided and pass-through configurations

· Utilizes hands-free scope handling system for HLD, drying, storage and transport

Proposed Solution: Medivator Endodry scope storage cabinet and all additional needed accessories.

Place of Performance:

Department of Veterans Affairs Beckley VA Medical Center 200 Veterans Ave.

Beckley WV 25801 The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below.

If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:

(1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.

(2) Is your company considered small under the NAICS code identified under this RFI?

(3) Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?

(4) If you are a small business and you are an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?

(5) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.

(6) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract?

(7) Please provide general pricing for your products/solutions for market research purposes.

(8) Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes?

*** Submissions addressing Section (8) should show clear, compelling, and convincing*** evidence that all equal to items" meet all required salient characteristics.

Responses to this notice shall be submitted via email to Michael.Jones16@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Wednesday, June 18, 2025, at 10:00AM EST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.