36C24525Q0263_1.docx

DOCX document 24 KB Posted

Attached to
6640--Leica HistoCore BIOCUT Microtome Brand Name Only
Solicitation number
36C24525Q0263
Issued by

About this file

This is a Combined Synopsis/Solicitation notice from the Department of Veterans Affairs (VA) Maryland Health Care System seeking a Leica HistoCore BIOCUT Manual Microtome (brand name only) for the Beckley WV VA Medical Center. The equipment will be used to cut tissue ribbons for microscopic slides for pathologic examination.

The solicitation (36C24525Q0263) requires specific capabilities including: manual operation with no automation or electronics, manual auto advance feature, compatibility with both high and low-profile microtome blades using a 2-in-1 blade holder, personalized coarse feed wheel, antistatic waste tray, and adjustable trim level. Responses are due by February 4, 2025, at 4:00 PM Eastern Time. The procurement falls under PSC 6640 and NAICS 334516, with no set-aside specified. The contracting point of contact is Contracting Officer Theresa Thomas.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice

SUBJECT*
Leica HistoCore BIOCUT Microtome Brand Name Only

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
21902
SOLICITATION NUMBER*
36C24525Q0263
RESPONSE DATE/TIME/ZONE
02-04-2025 4PM EASTERN TIME, NEW YORK, USA
ARCHIVE
10 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SBA
PRODUCT SERVICE CODE*
6640
NAICS CODE*
334516
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

VA Maryland Health Care System Contracting Officer (90C) P.O. Box 1000, Bldg. 101, Room 26 Perry Point MD 21902

POINT OF CONTACT*

Contracting Officer Theresa Thomas theresa.thomas7@va.gov

PLACE OF PERFORMANCE

ADDRESS
Beckley WV VA Medical Center

200 Veterans Ave.

Beckley, WV. 25801

POSTAL CODE

COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

STATEMENT OF WORK

Leica HistoCore BIOCUT Manual Microtome Brand name only

This machine’s main function is to cut tissue ribbons for microscopic slides for pathologic examination.

SALIENT CHARACTERISTICS

The Microtome MUST have the following capability:

· The Microtome MUST be manual unit. (We do not want any automation or electronics on this machine.)

· Must have a manual auto advance feature.

· Can be used with high or low-profile microtome blades on the same locking mechanism.

· Needs to have a personalized coarse feed wheel.

· Ability to switch between high AND low profile blades by using a 2-in-1 blade holder.

· Should have an antistatic waste tray.

· Needs to have high and low-profile blades.

· Should have adjustable trim level.

See attached document: 36C24525Q0263 Leica Microtome.

See attached document: Single Source Justification MPT to SAT Leica HistoCore BIOCUT Microtome 2_Redacted.