36C24523Q0796_1.docx
DOCX document 23 KB Posted
- Attached to
- J056--Replace and Install Door Assemblies, Automatic Door Operators and Controllers. 688-23-4-459-0374 (VA-23-00079898) Federal contract opportunity
- Solicitation number
- 36C24523Q0796
About this file
This is a combined synopsis/solicitation notice from the Department of Veterans Affairs seeking replacement and installation of door assemblies, automatic door operators, and controllers at various locations within the Washington DC VA Medical Center. The solicitation number is 36C24523Q0796 and responses are due by July 14, 2023 at 10:00 AM Eastern Time. The work includes replacing failed door units and automatic operators, as well as installing new operators and actuator controllers, at nine door locations to address accessibility, security, and workflow issues. The contractor must provide all labor and parts to complete the services defined in the statement of work, which involves installing presence sensors and integrating access controls as applicable to comply with industry standards and codes.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24523Q0796 0001_1.docx | DOCX document | |
| 36C24523Q0796 DC Door Assemblies RFQ.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice
| SUBJECT* |
| Replace and Install Door Assemblies, Automatic Door Operators and Controllers. 688-23-4-459-0374 |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 21201 |
| SOLICITATION NUMBER* |
| 36C24523Q0796 |
| RESPONSE DATE/TIME/ZONE |
| 07-14-2023 10am EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SBA |
| PRODUCT SERVICE CODE* |
| J056 |
| NAICS CODE* |
| 238290 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
VAMC
10 N Greene St Baltimore MD 21201
POINT OF CONTACT*
Contracting Officer William Chris Galletta william.galletta@va.gov Services team One
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
VAMC
50 Irving St
Washington DC
20422
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov |
| URL DESCRIPTION |
| Department of Veterans Affairs |
| AGENCY CONTACT’S EMAIL ADDRESS |
| william.galletta@va.gov |
| EMAIL DESCRIPTION |
| NCO5 |
DESCRIPTION
See attached document: 36C24523Q0796 DC Door Assemblies RFQ.
The Contractor shall provide all labor and parts necessary to complete services defined in this Statement of Work for the Washington DC VA Medical Center VISN 05 located at 50 Irving Street NW, Washington DC 20422. The services shall encompass needed replacement and installation of door unit assemblies, replacement of failed automatic door operators as well as the installation of operators and actuator controllers needed at other doorways that have been identified as deficient and non-compliant with the Architectural Barriers Act Accessibility Standard to correct accessibility requirements for disabled persons. This installation will correct issues of security for the building, correct ADA Compliance issues and maintain secured areas in which workflow requires continuous flow throughout the operational hours within the facility such as the SPS corridor.
The following provides a breakdown in Scope for each location and a comprehensive description of involved doors. Current condition of the doors impedes the flow of patients entering and exiting the facility and areas within, especially those with mobility challenges as failed operators require more pressure to open and the doors lacking operators make entering areas such as restroom challenging. Additional concerns being addressed are those of security of the building This service is necessary to maintain compliance with ADA (Americans with Disabilities Act) and NFPA 101 (Life Safety Code) requirements.
Included in this requirement are the following nine door locations. For each location the scope provides detail of how the door is to operate and be controlled. For each location as required to comply with BHMA A156.19 and A156.10 presence sensors shall be installed as stated in sections 7.6.1 and 8.1.4. Additionally, this includes the integration of access controls when applicable (by others) to secure the doors.
| *= Required Field |
| Combined Synopsis/Solicitation Notice |
Combined Synopsis/Solicitation Notice
File details come from the government source that posted it. Updated .