Partition As-Builts.pdf
PDF 599 KB Posted
- Solicitation number
- 36C24522B0003
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Tile Selection.png | PNG image | |
| Grout Selection.jpg | JPG image | |
| 36C24522B0003 0002.docx | DOCX document | |
| Floor Drain Detail.pdf | ||
| 540 22 123 Corridor.pdf | ||
| 540 22 123 Paint and Repair Showers on 3A Drawing.pdf | ||
| 36C24522B0003 0001.docx | DOCX document | |
| Combined Specs R2.pdf | ||
| 36C24522B0003_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5/8" G.W.B.
3 5/8" METAL STUDS
BASE - SEE FINISH
SCHEDULE FOR TYPE
TRACK RUNNER
FLOOR SLAB
PARTITION
AS DETAILED
P2
SIMILAR TO P2 WITH 2 1/2"
METAL STUDS
P2A
CHASE OF FURRED PARTITION WITH
DRYWALL BUILT TO 6'-4" A.F.F.
P2B
PARTITION
PARTITION
4 1 /4"
4 7 /8"
1 LAYER 5/8" G.W.B.
ACOUSTICAL BATT
INSULATION
5/8" G.W.B.
3 5/8" METAL STUDS
BASE - SEE FINISH
SCHEDULE FOR TYPE
TRACK RUNNER
FLOOR SLAB
PARTITION
AS DETAILED
P1
SIMILAR TO P1 WITH
2 1/2" METAL STUDS
P1A
SIMILAR TO P1 WITH
6" METAL STUDS
P1B
PARTITION
PARTITION
4 7 /8"
1 LAYER 5/8" TYPE 'X' G.W.B.
THERMA FIBER
BATT INSULATION
(MINERAL WOOL)
TYPE 'X' 5/8" G.W.B.
3 5/8" METAL STUDS
BASE - SEE FINISH
SCHEDULE FOR TYPE
TRACK RUNNER
FLOOR SLAB
1 HR. PARTITION
UL DES. U465
SIMILAR TO P5 WITH
2 1/2" METAL STUDS
P5A 1 HR. PARTITION
P5
ACOUSTICAL BATT
INSULATION
1/2" CEMENT BD. @ CERAMIC
TILE WITH THINSET
3 5/8" METAL STUDS
CERAMIC TILE
WITH THINSET (VERIFY
HEIGHT)
CERAMIC TILE COVE BASE
WITH THINSET
FLOOR SLAB
PARTITION
4x8 CERAMIC TILE
AS DETAILED
P3
4x4 CERAMIC TILE
AS DETAILED
P3A PARTITION
1/2" CEMENT BOARD
ACOUSTICAL BATT
INSULATION
1/2" CEMENT BOARD
WITH THINSET CERAMIC TILE
3 5/8" METAL STUDS
CERAMIC TILE
WITH THINSET
CERAMIC TILE COVE BASE
THINSET
FLOOR SLAB
PARTITION
FURRED OR CHASE PARTITION WITH
4x8 CERAMIC TILE
P4
SIMILAR TO P4 WITH
2 1/2" METAL STUDS
P4A PARTITION
1/2" CEMENT BOARD
SIMILAR TO P3 WITH
6" METAL STUDS
P3B PARTITION
5/8" G.W.B.
BASE - SEE FINISH
SCHEDULE FOR TYPE
FLOOR SLAB
PARTITION
AS DETAILED
P7
1 1 /2"
HAT CHANNEL AS REQ'D
A0-GNA0-GN
A0-GN
A0-GN
A0-GN
A0-GN
A0-GN
A0-GN
4 5 /8"
1" FIRE-SHIELD
SHAFTLINER
THERMA FIBER BATT
INSULATION (MINERAL WOOL)
1 LAYER 1/2" CEMENT BD. @ CERAMIC TILE WITH
THINSET (P6A ONLY)
CH STUD
CERAMIC TILE (P6A ONLY)
J TRACK
FLOOR SLAB
1 HR. SHAFT WALLP6
THERMA FIBER BATT
INSULATION (MINERAL WOOL)
CERAMIC TILE
SIMILAR TO P6 WITH CERAMIC TILE
AND CEMENT BOARD
P6A 1 HR. SHAFT WALL
A0-GN
FLOOR SLAB
PARTITIONP8
EXISTING WALL
1/2" CEMENTITIOUS
TILE BACKER BOARD
CERAMIC TILE W/
THINSET
PARTITION
FURRED OR CHASE PARTITION WITH
4x4 CERAMIC TILE
P4B
CEILING
SEE REFLECTED
CEILING PLAN
CEILING
SEE REFLECTED
CEILING PLAN
UL U499
CEILING
SEE REFLECTED
CEILING PLAN
1 LAYER 5/8" TYPE 'X'
GYPSUM BOARD
4x8 CERAMIC TILE
AS DETAILED
PARTITIONP8A
4x4 CERAMIC TILE
AS DETAILED
CERAMIC TILE AND BACKER
BOARD BOTH SIDES. SEE
FINISH SCHEDULE
FOR TILE SIZES
P3C PARTITION
1 LAYER 1/2" CEMENT BD. @ CERAMIC
TILE WITH THINSET (P6A ONLY)
CEILING
SEE REFLECTED
CEILING PLAN
HEADWALL
PARTITION
P9
SEE 1/A9.3
AS DETAILED
PARTITIONS PARALLEL
TO FLUTES
PARTITIONS PERPINDICULAR
TO FLUTES
CEILING
SEE REFLECTED
CEILING PLAN
1/2" CEMENTITIOUS
TILE BACKER BOARD
5 1 /4"
1" FIRE-SHIELD
SHAFTLINER
THERMA FIBER BATT
INSULATION (MINERAL WOOL)
2 LAYERS 5/8" TYPE 'X' G.W.B.
CH STUD
BASE - SEE FINISH
SCHEDULE FOR TYPE
J TRACK
FLOOR SLAB
2 HR. SHAFT WALL
UL DES. U438
5 1/4"
P10
THERMA FIBER BATT
INSULATION (MINERAL WOOL)
CEILING
SEE REFLECTED
CEILING PLAN
1 LAYER 1/2" CEMENT BD.
@ CERAMIC TILE WITH
THINSET (P10A ONLY)
2 LAYERS 5/8" TYPE
'X' G.W.B.
SIMILAR TO P6 WITH CERAMIC TILE
AND CEMENT BOARD
P10A 2 HR. SHAFT WALL
4 3 /8"
4 5 /8"
1. DIMENSIONS ARE TO THE FACE OF FINISHED WALL SURFACE UNLESS NOTED OTHERWISE.
2. REFER TO THE REFLECTED CEILING PLANS FOR PROPOSED CEILING HEIGHTS AND COORDINATED LOCATIONS OF ALL ELECTRICAL, HVAC AND FIRE PROTECTION DEVICES TO BE INSTALLED IN OR ON FINISHED CEILINGS.
3. UNLESS NOTED OR SHOWN OTHERWISE, DUCTWORK, PIPING, CONDUIT AND STRUCTURAL ELEMENTS ARE NOT TO BE
EXPOSED WITHIN FINISHED SPACES.
4. REPLACE OR PATCH DAMAGED FIRE PROOFING MATERIAL THAT HAS BEEN DAMAGED OR REMOVED DUE TO DEMOLITION WORK OR OTHER CONSTRUCTION ACTIVITY. REFER TO THE PROJECT MANUAL AND THE FIREPROOFING SCHEDULE FOR MATERIAL SPECIFICATIONS AND SPECIFIC DESIGN REQUIREMENTS FOR EACH ASSEMBLY AFFECTED.
5. THE KEYING OF PARTITION TYPES ON THE PLANS IS INTENDED TO AID THE CONTRACTOR IN UNDERSTANDING THE VARIOUS CONDITIONS LIKELY TO BE ENCOUNTERED. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING WHAT MATERIAL (TYPES AND SIZES OF FURRING) IS REQUIRED TO COMPLETE THE PROJECT AS SHOWN.
6. WHERE NEW PARTITIONS ABUT AND ALIGN WITH EXISTING PARTITIONS OR OTHER SURFACES, FINISHED
SURFACES SHALL BE IN THE SAME PLANE.
7. PROVIDE 6”HIGH, 14 GA. SHEET METAL REINFORCEMENT FOR WALL MOUNTED EQUIPMENT UNLESS NOTED
OTHERWISE TO BE OF MORE SUBSTANTIAL REINFORCEMENT
8. WOOD USED FOR FRAMING AND BLOCKING SHALL BE FIRE-RETARDANT TREATED WOOD, U.L. LABELED.
9. ALL EXISTING AND NEW PENETRATIONS, VERTICAL AND HORIZONTAL ARE TO BE PROVIDED WITH AN APPROVED THROUGH-PENETRATION FIRESTOP SYSTEM HAVING A SMOKE RESISTANCE AND/OR FIRE RESISTANCE RATING
EQUAL TO OR GREATER THAN THE ASSEMBLY PENETRATED.
GENERAL NOTES:
PARTITION TO BE PROVIDED- PROVIDE
P1 UNLESS INDICATED OTHERWISE
DOOR - KEYED TO DOOR SCHEDULE
EXISTING DOOR AND FRAME TO BE
REMOVED
EXISTING PARTITION TO REMAIN
Floor Plan Key
EXISTING PARTITION TO BE REMOVED
FROM FLOOR TO STRUCTURE ABOVE-
REMOVE ALL ITEMS CONTAINED WITHIN
OR ATTACHED TO PARTITION,
INCLUDING INTEGRAL COVE BASE
(GLAZED TILE, TERRAZZO, ETC.)
2 HOUR FIRE RATED PARTITION
1 HOUR FIRE RATED PARTITION
1 HOUR SMOKE PARTITION
CRASH RAIL
HANDRAIL
5 1 /2"
14 GAUGE GALVANIZED
SHEET METAL BACK UP
8"
1'
- 2
3'- 0"
A .F
.F
PROVIDE WHERE 'HR' IS
INDICATED ON PLAN.
DRYWALL
20 GAUGE METAL
STUDS AT 16" O.C.
CONTINUOUS 14 GAUGE GALVANIZED
STEEL PLATE SECURED TO EACH STUD.
PLATE TO SPAN A MINIMUM OF 3 STUDS.
16" O.C.
U.N.O.
HE
IG
HT
V
AR
IE
S
" P
LA
TE CRASH RAIL
14 GAUGE GALVANIZED
SHEET METAL BACK UP
8"
1'
- 2
CRASH RAIL
3'- 0"
A .F
.F
8"
PROVIDE WHERE 'CR' IS
INDICATED ON PLAN.
EXISTING CONCRETE DECK
DEFLECTION CHANNEL
CEILING RUNNER
3/4 " M
AX
GYP. BD. SEE
PARTITION TYPES
SEALANT TYP.
(FIRE STOP SEALANT AT
RATED PARTITIONS)
CEMENT BOARD
8" CERAMIC TILE
WATERPROOFING
MEMBRANE
4" CERAMIC COVE TILE
8"
SELF LEVELING CONCRETE TOPPING
SLOPE TO DRAIN 1/8" PER 1'-0"
TOPPING SLAB
FLOOR SLAB
NOTE: PROVIDE WHERE 'CG' IS INDICATED ON PLANS
HAND RAIL
WHERE OCCURS
#8x1" STAINLESS STEEL
SHEET METAL SCREWS
18" O.C. MAXIMUM
HIGH IMPACT VINYL
EXTRUSION - EXTEND FROM
TOP OF BASE TO 7'-0" A.F.F.
ACROVYN SM-20 OR
APPROVED EQUAL
HAND RAIL
WHERE OCCURS
CONTINUOUS
RETAINER
2" 3"
2" 3" architecture planning interior design IKM Incorporated
One PPG Place Pittsburgh, PA 15222
412.281.1337
VA
M C
C
LA
R K
SB
U R G
V A
V e te ra n s
A ff a ir s
D e p a rt m e n t o f
Date
Drawing No.
VA Project No.
DrawnChecked
Project Title
Building Number
Location
Drawing Title
Approved:
Approved: VAMC, CLARKSBURG
WEST VIRGINIAProfessional SealDate
VA FORM 08-6231, OCT 1978
Revisions
VA540-307
IKM Project No.
08-011
LLI ENGINEERING
6000 Brooktree Road, Ste. 300
Wexford, PA 15090 724 934 8800 Tel 724 934 8601 Fax www.lliengineering.com
AS-BUILT 4.1.2011
A0-GN
General Notes,Partition Types and Schedules
Modernize Inpatient Wards 7.15.09
1 1/2" = 1'-0"A0-GN
2 Hand Rail and Crash Rail
1 1/2" = 1'-0"A0-GN
1 Reinforcing/ Mounting Plate
1 1/2" = 1'-0"A0-GN
3 Guard Rail and Crash Rail
UL # HWD-0003 3" = 1'-0"A0-GN
4 Head of Wall Detail
3" = 1'-0"A0-GN
5 Shower Detail
NOTE: BALANCE OF TOILET ROOM
SIMILAR WITH NO FLOOR SLOPE
3" = 1'-0"A0-GN
6 Corner Guard CG
REF.
eos eos
H
G
D
C
B
A
B.6
A5.2
A5.2
A5.3
A5.3 43
Nourishment
Toilet/ Shower
308A
Diet Tech
Semi-Private Patient Room
Soiled Utility
Corridor 300A
Corridor 300B
Nurse Station North
Stair A
Toilet/ Shower
325A
Toilet/ Shower
322A Isolation Patient Room
Ante 319B
Toilet/ Shower
319A
Toilet/ Shower
314A
Physician Work Room
Staff Toilet
Toilet/ Shower
313A
Toilet/ Shower
307A
Private Patient Room
Med Room
Head Nurse
Electrical Closet
EXPANSION
JOINT
Ante 322B
64 SF
Toilet/ Shower
320A
Isolation Patient Room
Toilet/ Shower
340A
Exam Room
Gurney Alcove 300E
Equip.
Alcove
Dictation 309A
3'-2"
ASB
Private Patient Room
7B
Pipe Chase
Pipe Chase
193 SF
Private Patient Room
Semi-Private Patient Room
Semi-Private Patient Room
Semi-Private Patient Room
Toilet/ Shower
321A
300A
0E
2 324
9B
A
A
3A31 4A
322B2
2B
321A
320A
319A
319B2
Wheelchair Alcove
CG CG
CG
CG
CG
CG
CG
CG
Toilet/ Shower
339A
7B
9A
Private Patient Room
P2
311A
F.P. Closet 311A
Housekeeping Aid Closet
CG
CGCGCG
CG
CG
CG
P5
P2
P9 P2B
P5
P9
P2
P9
P2
P2
P9P9
P2
P2
P2
P2
P2
P2
P9
P2
P9
P9
P2
P9
P2
P2
P2
P3
P4
P3
P5 P4
P10A
P3
P3
P3
P8
P3
P3
P3
P3 P3
P4
P3
P3
P3
P4
P4
P3
P3
P3
P5B
P4
P3
P3
P3
P3
5 1/4" 1' - 2 1/4"
6' - 4 1/4"5 1/4"6' - 3 1/8"5"6' - 7"1' - 3 7/8"8' - 5"5"8' - 9 7/8"ASB 9'-8"5"4' - 2 5/8"5"ASB 5'-6 1/2"
P3 P8
P5
P3
P3
P3
P3
P3
P3
P4
P2
P2
P2
P3
P4
P3 P3
P4B
P3P3
P8
P3
P4
BE
D
3'
- 8
3'
- 8
BE
D
3'
- 8
3'
- 8
P3B
10"
75.00°
75.00°
75.00°
5'
- 9
1/ 4"
7'
- 4
7'
- 1
1 7 /8"
ASB 6'-3"
3'
- 6
10"
3'
- 6
3/ 8"
P5
P5B
P5
4' - 10 3/8" 11' - 0" 9' - 6 3/8" 10 3/8" 6' - 3" 5" 8' - 10 3/4" 7' - 7 5/8" 5" 4' - 0" 1' - 7 1/8"
AS
B
6'-
10"
105.00°
4' - 11 3/8"
4'
- 0
" 3'
- 0
BE
D
3'
- 8
3'
- 8
9 7/8"
3' - 4 7/8"
1'
- 5
3/ 4"
3'
- 0
P6
P5
4'
- 0
BE
D
3'
- 8
3'
- 8
1'
- 9
5"
R
9'
3/
4"
AS
B
'-1
1"
R
9'
3/
4"
AS
B
8'
- 5
9 7 /8"
1' - 6" 1' - 10"
ASB 7'-5"
9 7/8"
1'
- 6
1/ 4"
1'
- 5
3/ 4"
3'
- 4
4' - 2"
AS
B
'-7
7'
- 6 3/
4"
8' - 2" 1' - 10" 1' - 5 3/4"
9 7 /8"
3'- 2"
AS
B
1 1 /2"
3'
- 3
1' - 5 5/8"
4' - 2"
P3B
P3B
P3B
EQ
EQ
4'
- 0
4'
- 0
8'
- 9
1'
- 5
3/ 4" 10"
12' - 5 3/8"
105.00°
10' - 8"ASB
8' - 3"
7' - 0"
105.00°
R 39' - 10 7/8"
R 39' - 7 3/4"
BE
D
3'
- 8
3'
- 4
ASB 12'-6" 7' - 8"
8'
- 4
1'
- 6
AS
B
3'-
1/ 2"
3' - 2 5/8"
3' - 0"
BED
.00
ASB 3'-10"
ASB 3'-10"
2'- 6 1
/ 2"
AS
B
AS
B
8'- 2 1
/2" 5"
3'
- 9
AS
B 4'
-5
5'
- 0
1/ 8"
3'
- 4
9'
- 4 3/
8"
7' - 4 3/8" 5" 10' - 2 3/8"
7'
- 4
9' - 0"
1'
- 6
1'
- 1 0"
9 7/8"
105.00° 3' - 10"
5'
- 0
100.00° 6"
105.00°
A5.2 16
A5.217
6'
- 1
0 1 /4"
10 1/8"
CR/CR
CR/CR
CR
/C
R
CR/CR
CR/CR
CR
/C
R
HR
/C
R
HR
/C R
HR/CR
9'
- 8
CR/CR
CR/CR
CR
/C
R
HR
/C
R
HR/CRHR/CRHR/CRHR/CR
HR/CR HR/CR HR/CRHR/CR
HR/CR
HR/CR
HR/CR
HR/CR
HR
/C
R
HR
/C R
HR
/C
R
HR/CRHR/CRHR/CR
HR/CR HR/CR HR/CR HR/CR
HR
/C
R
HR
/C R
HR
/C
R
HR
/C R
HR
/C
R
HR
/C
R
HR
/C R
CR
/C
R
CR
/C
R
CR/CR
CR/CR
ASB 19'-11" ASB 20'-0"
4' - 0"4' - 0"
3'
- 6
3'
- 6
3'
- 6
3'
- 6
3'
- 6
3'
- 6
3'
- 6
3'
- 6
3' - 6"
P8
P7
3'
- 5
TY
PI
CA
L
HO
LD
3'
- 0
TY
PI
CA
L
HO
LD
3'
- 0
S.U.
EMPTY
BAG
P10
P10
P10
RED BAG
BOX
5' - 0"2' - 6"
TRASH
CAN
SPD
CART
P10
P10
P10
P10
P9
7' - 0"
0"
A5.2
P I P
E C
H A
S E
P10
P8
CRASH CART COPIERI.V.
CART
CHART
RACK
CHART
RACK
CHART
RACK
CG
CR
/C
R
ICE
MACHINE
CG
8' - 0" ASB 18'-5"
Clean Utility
A9.3
P4
P3
P8
P7
P4B
P4
P5
P5
P4
A5.2
A5.2 21
A5.2
C-LOCKERS
C-
LO
CK
ER
S
MED
CART
MED
CART
RX DISP.
RX DISP.
P4
P5
P10
P6
P5
P7
'F5' SEE A9.1
P2
P5
P5
P5
P4P8 P8
P7
P7
P2
P2
E
P2 P2
Gurney Alcove 300H
CL-11
3'
- 6
5/ 8"
P7
1' - 10"4'
- 0
H
4'
- 3
RFI 40
7"
CL-10
CL-11 1
4' - 0"
1' - 6"
1' - 6"
CL-12
2"
1'
- 3
"3'
- 0
4'
- 0
322A 5' - 8"
CL-13
P5B
AS
B
6'- 6"
AS
B
3'- 0"
ASB 17' -2"AS
B
5'- 1"
ASB 13'-7"
AS
B
'-1
6'
- 7
2' - 9" 3' - 0"
ASB 8'-6"
AS
B
1/
2"
Day Room
4' - 10"
ASB 10'-1"
AS
B
8'- 7"
ASB 5'-9"
architecture planning interior design IKM Incorporated
One PPG Place Pittsburgh, PA 15222
412.281.1337
VA
M C
C
LA
R K
SB
U R G
V A
V e te ra n s
A ff a ir s
D e p a rt m e n t o f
Date
Drawing No.
VA Project No.
DrawnChecked
Project Title
Building Number
Location
Drawing Title
Approved:
Approved: VAMC, CLARKSBURG
WEST VIRGINIAProfessional SealDate
VA FORM 08-6231, OCT 1978
Revisions
VA540-307
IKM Project No.
08-011
LLI ENGINEERING
6000 Brooktree Road, Ste. 300
Wexford, PA 15090 724 934 8800 Tel 724 934 8601 Fax www.lliengineering.com
AS-BUILT 4.1.2011
A4.2
Enlarged Partial Plan Modernize Inpatient Wards 7.15.09
N
E
W
S
ALL PARTITIONS 'P1' UNLESS NOTED OTHERWISE
L
K.5
K
H
N
A5.3 65
Stair B
Private Patient Room
Toilet/ Shower
332A
Private Patient Room
Toilet/ Shower
333A
Toilet/Shower 334A
Private Patient Room
Toilet/ Shower
326A
Toilet/ Shower
325A
Toilet/ Shower
329A
Toilet/ Shower
328A
Private Patient Room
A
Private Patient Room
Toilet/ Shower
330A
325A
Private Patient Room
Semi-Private Patient Room
Semi-Private Patient Room
Nurse Sub Station
A
A
326A
330329
0A
9A
CG
CG
A
CG
P2
P2
P2
P9 P9
P2
P2
P2
P9
P2
P9
P2
P5
P2
P9
P2
P2B
P2B
P3
P3
P4P3
P3
P4
P3
P4
P3
P3
P3
P3
P3
P3
P4
P3
P3
P3
P3P3
P4 P3
P3
P3
P4
P3
P3
P2
P3
P3
P4
P4
P4
P3
P3
P3
ASB 19'-11" ASB 20'-0"
4' - 0" 4' - 0"
AS
B
4' -5
AS
B
0'3
AS
B
6' -1
/2" 5"
2'
- 6
1/ 2"
6'
- 8
5"
6'
- 7
5"
4'
- 9
4'
- 5
5" 7'
- 1 1/
2" 5"
AS
B
8'- 4"
5" 1'
- 1 1/
2" 8'
- 6
5" 6'
- 5 3/
8" 5"
4'
- 2
5/ 8"
5'
- 0
1/ 8"
3'
- 4
105.00° 3' - 10"
5'
- 0
75.00°
BED
3' - 8"
5' - 0" 1' - 8"
BED
1' - 0" 3' - 8" 3' - 8"
1' - 8 1/8" 2' - 7 7/8"
5'
- 4
BED
3' - 8" 3' - 8"1' - 0"
7' - 8 3/8" 5" 3' - 2"
1' - 5 1/4"1' - 10 3/4"
5/
8"
4' - 2"
5'
- 1
0"
4' - 9"
7' - 11 5/8"7'
- 3
9"
1' - 6"
3' - 2"
DOOR
2' - 8"
DOOR
75.00°
BED
3' - 8" 3' - 8"
3' - 1 7/8"
P2
7' - 5"
4"
16' - 0 3/8"
5' - 2"
4' - 0 5/8"
5 5/8"
BED
BED
75.00°
3' - 8"
3' - 8"
3' - 8"
3' - 8"
3' - 5 1/2"
4' - 8"
4' - 10" 2' - 0"
DOOR
CR/CR
CR/CR
CR
/C
R
5' - 0 5/8"
HR
/C
R
HR
/C R
HR
/C
R
HR
/C R
HR
/C
R
HR
/C
R
HR
/C R
HR
/C
R
HR
/C R
HR
/C
R
HR
/C R
3' - 6 3/8"
4' - 0"
0.
135.00°
3' - 6"
3'
- 6
5'
- 0
3' - 6"
3' - 6"
3' - 6"
3'
- 6
TYPICAL
HOLD
3' - 0" 3' - 5"
TYPICAL
HOLD
3' - 0"
M
A5.2 7
P4 P8
P4
P3
A
P4
P3
P5
A9.1
Gurney Alcove 300H
CL-1
3' - 6" 4'
- 4
EXISTING 6"
CHILLED WATER
LINE
C.T. ON 1/2" CEMENT BD.
3'
- 6
5/ 8"
P7
322A
DRAIN
AS
B
1/
2"
Day Room
Corridor 300C architecture planning interior design IKM Incorporated
One PPG Place Pittsburgh, PA 15222
412.281.1337
VA
M C
C
LA
R K
SB
U R G
V A
V e te ra n s
A ff a ir s
D e p a rt m e n t o f
Date
Drawing No.
VA Project No.
DrawnChecked
Project Title
Building Number
Location
Drawing Title
Approved:
Approved: VAMC, CLARKSBURG
WEST VIRGINIAProfessional SealDate
VA FORM 08-6231, OCT 1978
Revisions
VA540-307
IKM Project No.
08-011
LLI ENGINEERING
6000 Brooktree Road, Ste. 300
Wexford, PA 15090 724 934 8800 Tel 724 934 8601 Fax www.lliengineering.com
AS-BUILT 4.1.2011
A4.3
Enlarged Partial Plan Modernize Inpatient Wards 7.15.09
N
E
W
S
ALL PARTITIONS 'P1' UNLESS NOTED OTHERWISE
| 08011 VA Clarksburg 3A As Built 4012011 - Sheet - A0-GN - General Notes,Partition Types and Schedules.pdf |
| 08011 VA Clarksburg 3A As Built 4012011 - Sheet - A4-2 - Enlarged Partial Plan.pdf |
| 08011 VA Clarksburg 3A As Built 4012011 - Sheet - A4-3 - Enlarged Partial Plan.pdf |
File details come from the government source that posted it. Updated .