36C24520Q0731.docx
DOCX document 16 KB Posted
- Solicitation number
- 36C24520Q0731
About this file
This special notice from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 5 concerns preventative maintenance services for a Canon CT scanner and related equipment located at the Beckley VA Medical Center in West Virginia. The notice is seeking potential sources to provide full-service coverage and support for the listed Canon medical imaging systems, which include an Aquilion One 320 Genesis Series CT scanner, replacement parts, installation, calibration, labor, and response times. Interested parties must respond by September 15, 2020 to be considered. The notice includes descriptions of the required maintenance and technical support services, personnel qualifications, covered and excluded equipment options, and additional terms such as discounts and cybersecurity protections.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Contract Opportunity Special Notice
PRODUCT SERVICE CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
GENERAL INFORMATION
ADDITIONAL INFORMATION
* = Required Field Contract Opportunity Special Notice J065 Canon CT service contract (VA-20-00077463)
*INTENT TO SOLE SOURCE NOTICE
25405 36C24520Q0731 N 811219 Department of Veterans Affairs
VAMC (613)
VISN 5 Contract Satellite Office 510 Butler Avenue, Building 306A Martinsburg WV 25405
CO
Craig Armagost craig.armagost@va.gov 304-263-0811 X4492 Veterans’ Health Administration, Network Contracting Office 5, is issuing this Notice of Intent to Sole Source in order to identify any potential sources that have the resources and capabilities to support and provide preventative maintenance for Canon USA Medical CT products as described below in the Statement of Work. The location of these services will be Beckley Wv VA Medical Center.
All response to this Intent to Sole Source are due by 9/15/2020, at 1:00 PM EST to craig.armagost@va.gov.
Statement of Work
2. Required Services
2.1 Contractor will be required to provide full-service coverage on the equipment listed below. Coverage includes all replacement parts, installation, calibration, labor, and travel necessary to bring the listed equipment to manufacture operating specifications. Throughout the term of the contract, all maintenance (scheduled or unscheduled), shall be provided during the contract business hours of 8:00 AM – 5:00 PM, Monday through Friday, excluding federal holidays. A one (1) hour telephone response is required by the contractor to provide an initial consultation or possible interim measures until the repair can be completed. The contractor is required to respond on-site within four (4) business hours after Biomedical Equipment Support has placed the service call. The VA requires all listed equipment to meet a minimum 95% uptime for the period of performance on a 24 hours basis.
2.2 Contractor will be required to provide technical phone support to the Biomedical Equipment Support Specialist within one (1) hour of initial consultation.
2.3 Contractor will provide Priority parts delivery for all required parts needed to bring the listed equipment to manufacturer operating specifications. All parts shall be Canon OEM (original equipment manufacturer) or equivalent.
2.4 There will be no additional charges for all required hardware and software upgrades during the term of the contract.
2.5 All services for this contract must meet manufacturer's performance and technical specifications, Federal Regulations, and other specifications that may apply such as National Electric Code (NEC), Life Safety Code (LSC), Joint Commission (JC), and VA Regulations.
2.6 The contractor shall ONLY respond to service calls placed by the Biomedical Equipment Support Section or designee.
2.7 ALL SERVICE ENGINEERS MUST REPORT to the Biomedical Equipment Support Section or the Radiology Department to sign in before work is begun on the premises of the Beckley VAMC, and to sign out after work has been completed. The contractor must furnish a detailed field service report, or equivalent, showing work completed, listing all repairs and/or repair parts used to maintain operating efficiency of the equipment. When possible, this report may be delivered to Biomedical Equipment Support before contractor leaves the station or via email to Stacy.Johnson@va.gov. If it is necessary for the contractor to work after 5:00pm, permission must be granted from the Biomedical Support Specialist or designee. If the service was completed after regular duty hours, the FSE will sign out and leave the report in the Police Office, 1B-124H of the hospital. Payment will be withheld pending receipt of this report. The service report from the contractor must contain, at a minimum, the following information:
| a. | Date and time of the contractor’s arrival on station, |
| b. | Type, model, site ID, and serial number(s) of all equipment on which maintenance was |
performed,
| c. | Total time spent performing maintenance, excluding travel time, |
| d. | Detailed narrative description of the malfunction or PM action required, |
| e. | Complete list of parts replaced, |
| f. | Comments as to the cause of the malfunction when applicable, |
| g. | Date and time the work is completed. |
2.8 There is a potential for exposure to bloodborne or other infectious material with equipment throughout the hospital. All maintenance persons must use the “Universal Precautions” (i.e. decontamination of medical equipment, wearing protective gloves, aprons, and goggles) during cleaning and maintenance/repair procedures required by this contract.
2.9 The following is the list of equipment covered under this agreement:
Attachment A Equipment List This agreement includes coverage for the following items. All other options, including but not limited to lasers, injectors, sources, power conditioners (PCDUs, VRDUs, UPSs, etc.) and other non-Canon Medical Systems options, are not covered by this agreement.
For additional options not listed, please contact your local Service Manager.
SYSTEM
AQ/ONE-320G.000 (AQUILION ONE 320 GENESIS
SERIES DYNAMIC VOLUME CT SCANNER WITH AIDR
3D)
GLASSWARE
CTTUBE.E.125K.010 (ROTATION COUNT: UP TO 125,000
USAGE FEE: $3.00) QTY 1
EXCLUDED OPTIONS
PICM (PDU INRUSH CURRENT MONITOR ***NOT
AVAILABLE IN CA***)
VRDU/TIC/BATT (BATTERY CABINET FOR ANY TIC
VRDU)
VRDU/TIC/480I/O-125 (VRDU 480 V INPUT / 480 V
OUTPUT)
RSAP/TIC/HW (REMOTE STATUS ALARM PANEL)
INCLUDED OPTIONS
CHEG-GATING.010 (ECG GATED SCANNING ACQUISITION)
CGS-56A/1B.010 (FAST SCAN AND X-RAY POWER UPGRADE KIT)
CGS-59A/1B.010 (320-SERIES-V TO 640-SERIES-V DETECTOR
UPGRADE)
VLO-BASE/LU/PKG/SNGL-USER.010 (VITREAEXTEND, SINGLE
USER BASE PACKAGE)
VLO-CARDI/LU/PKG.010 (VITREA CT CARDIAC *requires Vitrea base) VLO-COLON/LU/PKG.010 (VITREA CT Colon Analysis *requires Vitrea base) VLO-LIVER/LU/PKG.010 (VITREA CT Liver Analysis *requires Vitrea base) VLO-LUNGNO/LU/PKG.010 (VITREA CT Lung Analysis *requires Vitrea base) AN ADDITIONAL 1% DISCOUNT IS AUTOMATICALLY APPLIED TO THE DISCOUNTED SELL PRICE, PROVIDED CMSU RECEIVES A PURCHASE ORDER FOR THE INITIAL ONE (1) YEAR SERVICE AGREEMENT, WHICH INCLUDES FOUR (4) ONEYEAR OPTIONS THAT MUST BE EXERCISED ANNUALLY AT THE TIME OF RENEWAL, CONTINGENT ON GOVERNMENT
FUNDING.
ADDITIONAL COMMENTS
Gateway Program Cybersecurity Protection:
Gateway Gold cybersecurity connectivity will be included, at no charge to the Customer, during the post-warranty contract term listed on page 1 of this Agreement. For Point of Purchase agreements, coverage during the Warranty term is also included at no additional charge to the customer.
Gateway Gold cybersecurity protection, with remote system diagnostics, shields Canon imaging devices from malicious factors; the remote system diagnostics provided, via InnerVision® Plus, facilitates remote applications support, including a message alert system which allows for early detection and prevention of system problems. In addition, the Gateway Program includes cybersecurity incident response 24X7, 360° Connect Online access, HIPAA compliant authentication, VPN tunnel and FMI updates
4. Personnel Qualifications
Contractor personnel performing maintenance, repair services, and providing technical support must be fully qualified and competent.