This is a Sources Sought Notice issued by the Department of Veterans Affairs, Altoona VA Medical Center, seeking market research on potential suppliers for a CT Scanner Contrast Power Injection System. The solicitation number is 36C24426Q0400, with responses due by March 23, 2026 at 8:00 AM Eastern Time. The contracting office is located in Pittsburgh, PA (ZIP 15215), and the point of contact is Contract Specialist Jefferson Mann at jefferson.mann@va.gov or 717-202-5456. Responses should be submitted via email directly to Mr. Mann.
The Altoona VA Medical Center requires a complete Power Injection System to replace their end-of-life Stellant Flex system with newer technology. The system must meet salient characteristics including power injection capability for complex contrast-enhanced CT protocols, multi-phase programming with hold/pause features, storage and recall of up to 250 protocols, on-board eGFR and weight-based dosing, programmable pressure limits, automated data capture, and PACS/RIS/speech recognition system interconnectivity. Respondents must provide company information, SAM UEI number, business size classification, relevant government contracts (FSS, eCAT, SAC, NAC, NITTAC, or NASA SEWP), product brochures and materials, and answer questions regarding manufacturer status, distributor relationships, authorization letters, and any modifications to the equipment. The NAICS code is 334517 with a small business size standard of 1200 employees. Delivery and installation shall be coordinated upon award with at least five business days' notice prior to shipment. This is market research only; no binding contract will result from responses, and the government will not reimburse response costs.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUBJECT*
CT Scanner Power Injection System
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 15215 |
| SOLICITATION NUMBER* |
| 36C24426Q0400 |
| RESPONSE DATE/TIME/ZONE |
| 03-23-2026 8:00AM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 15 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6525 |
| NAICS CODE* |
| 334517 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 4 1010 Delafield Road Pittsburgh, PA 15215
POINT OF CONTACT*
Contract Specialist Jefferson Mann jefferson.mann@va.gov 717-202-5456
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
Altoona VA Medical Center
2907 Pleasant Valley Blvd
Altoona PA
| POSTAL CODE |
| 16602 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov |
| URL DESCRIPTION |
| Department of Veterans Affairs |
| AGENCY CONTACT’S EMAIL ADDRESS |
| jefferson.mann@va.gov |
EMAIL DESCRIPTION
DESCRIPTION
In accordance with FAR 10, Market Research, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to the Sources Sought Notice. The purpose of this announcement is to gain market research knowledge of potential qualified sources and their size classification.
The Department of Veterans Affairs, Altoona VA Medical Center, 2907 Pleasant Valley Blvd, Altoona, PA 16602, is seeking potential sources capable of providing a CT Scanner Contrast Power Injection System in accordance with the Draft Statement of Need (SON) below.
Please include the following information in your response:
1. Company name
2. Address
3. Contact person name, phone number and email address
4. SAM UEI #
5. Business size/classification/type (i.e. 8a, Hubzone, SDVOSB, VOSB, etc.)
6. FSS/eCAT/SAC/NAC/NITTAC/NASA SEWP or any Government held contract, if applicable provide the number.
7. NAICS: 334517
8. Size Standard: 1200 Employees
9. Provide brochures, pamphlets, hyperlinks, or any other materials necessary to determine material capabilities including special features and any express or implied warranties.
Please answer the following questions:
1. Are you the manufacturer, distributor, or equivalent solution to the above items? If not, can you provide additional information, as shown below? This confirms compliance with the nonmanufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.
2. If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, Point of Contact, and size status (if available).
3. If you’re a small business, are you an authorized distributor/reseller for the items identified above? If so, please include your letter of authorization on the OEM’s letterhead.
4. If you’re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is changed, assembled, or modified.
Responses to this Sources Sought Notice shall be submitted directly via email to jefferson.mann@va.gov. Responses that only include generic marketing material and do not provide for capability to meet requirements listed in the SON may not be considered. Responses must be received no later than 8:00 am ET, 03/23/2026. No solicitation document is available at this time. This notice is simply for Market Research Purposes Only. All information received in response to this RFI that is marked as proprietary will be handled accordingly. The VA will not reimburse any potential contractors for any costs associated with this Sources Sought Notice.
Page 1 of Page 1 of Statement of Need
CT Scanner Contrast Power Injection System Radiology Department Altoona VA Medical Center
Summary The Stellant Flex system is the current system being used in the Radiology CT scanner room at Altoona VA Medical Center (VAMC). The current system has reached end of life and Altoona VAMC requires a new system with the newest technology.
Project Scope The contractor shall provide delivery of a complete Power Injection System and all related Installation to make system fully ready for patient use in accordance with Original Equipment Manufacturer (OEM) specifications.
The CT Scanner Contrast Power Injection System shall at a minimum meet all the following salient characteristics.
The Stellant FLEX- Medrad Stellant FLEX Injection System is a Name Brand Product provided for reference of salient characteristics only.
Salient Characteristics
· Power injectors
· Designed for complex contrast enhanced CT protocols
· Creates a tight contrast bolus
· Enables precisely timed contrast delivery
· Provides more uniform attenuation of the right and left ventricles
· Minimizes artifacts by achieving proper attenuation levels
· Visualize the right coronary arteries and right ventricles in a single study by achieving more uniform attenuation
· Informatics ready platform – enables interconnectivity between your CT scanner, power injector, PACS, RIS, & speech recognition systems
· Storage and recall of up to 250 protocols
· Enhanced protocol manager
· Snap-on/twist-off syringe design
· Automatic plunger advance and retract when attaching and detaching syringes
· Automatic filling and priming
· Multi-phase programming (with hold/pause feature)
· Integrated saline test inject
· Programmable pressure limit
· On-board eGFR and weight-based dosing
· Injection enabled when head is tilted down
· Automated data capture
· Interface with PACS/RIS/SR
· Export of a DICOM secondary capture to PACS
Delivery/Installation Shall be coordinated upon award and at least 5 business days prior to shipment End of Document Page 1 of