About this file

This document is an architectural floor plan for a hospital facility. The plan depicts a multi-floor layout with detailed room designations and mechanical systems. The facility includes numerous patient care areas organized by room type and function, including 42 numbered patient bed rooms (ranging from single-bed isolation rooms to two-bed standard rooms), patient bathrooms and toilets distributed throughout, and specialized medical spaces such as medication rooms, treatment rooms, nourishment rooms, and biomed shops.

The layout features support spaces including nurse stations, staff break rooms, administrative offices (nurse manager, assistant nurse manager, chief of hospitalist, case manager), storage facilities (clean linen, soiled linen, equipment storage, logistics supply), and utility areas (electrical closets, mechanical corridors, HAC units). Vertical circulation is provided by multiple elevators and stairs, with dumbwaiters positioned for medical cart distribution. The roof plan indicates sloped surfaces with a minimum 1/4-inch-per-foot slope, continuous curb perlite crickets, concrete pads for equipment, and drainage provisions including multiple FEC (field erected curb) locations. The grid system uses column references labeled 4 through 40 horizontally and S, R, P, N, M, L, K, J, I, H, G, E, C, B, Q, D vertically to establish spatial organization and coordinate locations throughout the facility.

View the file

Other files

File Type Posted
36C24426B0009 0002_1.docx DOCX document
SIGN IN SHEET FOR SHOWER REFURBISH.pdf PDF
ICRA formfor fourth floor shower refurbish.pdf PDF
36C24426B0009 0002.pdf PDF
36C24426B0009 0001.pdf PDF
36C24426B0009 0001_1.docx DOCX document
36C24426B0009_2.docx DOCX document
36C24426B0009.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UPUP

DN

DN

SL

OP

E 1/4

" P

ER

FO

OT

SL

OP

E 1/4

" P

ER

FO

OT

SL

OP

E 1/4

PE

R

FO

OT

CONCRETE

PADS

CONTINUOUS

CURB PERLITE CRICKET ACHIEVE 1/4"

PER FOOT MIN. SLOPE

DN

F.E.C.

F.E.C.

F.E.C.

4 5 6 7 8 9 10 11 12 13 14 15 16 19 20 21 22 23 25 27 28 29 30 31 32 34 35 36 37 38 39 4033

S

R

P

N

M

L

K

J

I

H

G

E

C

B

Q

D

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

HAND WASH HAND WASHHAND WASHHAND WASH

SL

OP

E

SLOPE

VALLEY RI

DG

E

SLOPE

VALLEY SL

OP

E

VALLE

Y

SLOPE

VALLEY

SL

OP

E

ROOF SYSTEM

WALKWAY PADS

ELECTRICAL

CLOSET

4044A

FEC

4035A

FEC

40E2

ELECTRICAL

CLOSET

40E3

ELECTRICAL

CLOSET

ELECTRICAL

CLOSET

4067A

FEC

40E1

ELECTRICAL

CLOSET

4002L

WAITING

P-5

ELEVATOR

P-6

ELEVATOR

S-7

ELEVATOR

4000L

CORRIDOR

HAC

4060A

BIOMED

CLOSET

BIOMED

SHOP

STORAGE

4053ELECTRICAL

CLOSET

4000E

CORRIDOR

4050A

4047MED

CART

CHARGING

RM

EQUIP

STORAGE

4063CHIEF

OF

HOSPITALIST

40751

BED

ISOLATION

RM

4000E

CORRIDOR

4000L

LOBBY4000W

CORRIDOR

HAC

4081B4081A

PATIENT

TOILET

40811

BED

RM

40802

BED

RM

4080B4080A

PATIENT

TOILET

40792

BED

RM

4079A

PATIENT

TOILET

4079B

40781

BED

RM

4078A

PATIENT

TOILET

STORAGE

STAIR

40761

BED

RM 4075AANTE

RM

4076AANTE

RM

4076B

PATIENT

TOILET

4075B

PATIENT

TOILET

4074LOGISTICS

SUPPLY

RM

4073STAFF

BREAK

RM 4072MAIL

RM

4072B

TOILET

4072A

SHOWER

EQUIP

STORAGE

4069OFFICE

(2

PERSON)

4043PRIVATE

OFFICE

ASST

NURSE

MGR

STORAGE

4040NURSE

MGR

4039STAFF

BREAK

RM

4039A

STAFF

TOILET

4038A

PATIENT

BATH

40381

BED

ISOLATION

RM

40371

BED

ISOLATION

RM 4037BANTE

RM

4037A

PATIENT

TOILET

4036A

PATIENT

TOILET

PSYCH

OFFICE STAIR

4035ELECTRICAL

CLOSET

STORAGE

4033A

PATIENT

BATH

PATIENT

SHOWER

40331

BED

RM

PATIENT

SHOWER

4032A

PATIENT

BATH

4031A

PATIENT

BATH

PATIENT

SHOWER

40301

BED

RM

4030A

PATIENT

BATH

PATIENT

SHOWER

HAC

40272

BED

RM

4026A

PATIENT

TOILET

4027A

PATIENT

TOILET

40262

BED

RM

LINEN

STORAGE

40221

BED

RM

4022A

PATIENT

TOILET

40202

BED

RM4019A

PATIENT

TOILET

40192

BED

RM

ELECTRICAL

CLOSET4017A

PATIENT

TOILET

40172

BED

RM

4016CLEAN

LINEN

4015WARD

CLERK

SOILED

UTILITY4012A

PATIENT

TOILET

NOURISHMENT

40122

BED

RM

40112

BED

RM

4011A

PATIENT

TOILET

4010A

PATIENT

TOILET40101

BED

RM

STAIR 1

SHAFT4005

OFFICE

UNISEX

TOILET

CASE

MGR

40M2

MECH

CORRIDOR

NURSE

STATION

(4

WEST) 4110HOSPITALIST

(3

PERSON)

4110A

TOILET

4109A

TOILET

BED

RM

(4

PERSON)

4108TRAINING

RM

SOILED

UTILITY

WORKSTATION

LAUNDRY

40952

BED

RM

4095A

PATIENT

BATH

4094TREATMENT

RM

4094A

TOILET

4093A

TOILET

4092A

PATIENT

TOILET

40921

BED

RM

4091RESIDENTS

STUDENTS

(3

PERSON)

40882

BED

RM

4088A

PATIENT

TOILET

4087A

PATIENT

TOILET

40872

BED

RM 4090MEDICATION

RM

40M1

MECH

TRAINING

RM

DUMBWAITER

DUMBWAITER

NOURISHMENT

4108A

TOILET

SHAFT

DUMBWAITER

DUMBWAITER

ELEVATOR

ELEVATORELEVATORELEVATOR

40312

BED

RM

40322 BED

RM

4036BANTE

RM

MECH

CORRIDOR

4025MEDICATION

RM

4024NURSE

STATION

4020A

PATIENT

TOILET

DUMBWAITER

DUMBWAITER

DUMBWAITER

DUMBWAITER

MED

CART

CHARGING

RM

File details come from the government source that posted it. Updated .