S02 ACM Survey.pdf
PDF 29 MB Posted
- Attached to
- Z2DA--693-15-101 | Plumbing Upgrade Phase 3
- Solicitation number
- 36C24423R0048
About this file
This document provides details on a federal contract opportunity for plumbing upgrade services. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4 is soliciting proposals under solicitation number 36C24423R0048 for plumbing upgrade phase 3 services. Interested vendors should review the attached 29MB ACM survey file for additional requirement details. Proposals are due by the date specified on the Federal Business Opportunities website. The awarded firm will be expected to provide all necessary labor, materials, equipment, and supervision to complete the defined plumbing upgrade work at the specified VA location.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24423R0048 0006.docx | DOCX document | |
| 36C24423R0048 0005.docx | DOCX document | |
| PA 20230095 - 11.3.2023.pdf | ||
| 36C24423R0048 0004.docx | DOCX document | |
| S02 Amd 4 Gen Duty Valves.pdf | ||
| S02 Amd 4 Fac Water Distribution.pdf | ||
| LuzCty Wage 9-22-23.pdf | ||
| S02 RFI Responses.pdf | ||
| 36C24423R0048 0003.docx | DOCX document | |
| 36C24423R0048 0002.docx | DOCX document | |
| 36C24423R0048 0001.docx | DOCX document | |
| 36C24423R0048.docx | DOCX document | |
| S02 17 194 Specs.pdf | ||
| S02 17 194 DWGs.pdf | ||
| S02 SafetyHealthDuringConstruction 18S-15-346.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PARS
Environmental Inc.
COMPREHENSIVE ASBESTOS
SURVEY AND INVENTORY
BUILDING #1
Veterans Affairs Medical Center – Wilkes-Barre 1111 East End Boulevard Wilkes-Barre, Pennsylvania 18711
CONTRACT #GS-10F-0094W
TASK ORDER #0001
PREPARED FOR
Department of Veterans Affairs Veterans Affairs Medical Center – Wilkes-Barre 1111 East End Boulevard Wilkes-Barre, Pennsylvania 18711-0030
PREPARED BY
PARS Environmental, Inc.
500 Horizon Drive, Suite 540 Robbinsville, New Jersey 08691 609-890-7277 609-890-9116 (fax)
PARS PROJECT NO. 1040-01
OCTOBER 2014
Comprehensive Asbestos Survey and Inventory VAMC – Wilkes-Barre Building #1
PARS Project No. 1040-01
TABLE OF CONTENTS
1.0 BACKGROUND
2.0 INTRODUCTION
3.0 SITE DESCRIPTION
4.0 METHODOLOGY
4.1 ANALYTICAL METHODS:
4.2 FINDINGS
5.0 CONCLUSIONS AND RECOMMENDATIONS
FIGURES
SAMPLE LOCATION MAPS
TABLE 1
HOMOGENEOUS APPLICATION TABLE
TABLE 2
ABATEMENT COST ESTIMATE
APPENDIX A
CERTIFICATIONS
APPENDIX B
APPLICABLE REGULATIONS
APPENDIX C
PHOTO LOG OF CONFIRMED ASBESTOS CONTAINING MATERIALS
APPENDIX D
IATL CERTIFICATIONS
APPENDIX E
BULK SAMPLE LABORATORY REPORT
APPENDIX F
BULK SAMPLE CHAIN OF CUSTODIES
APPENDIX G
LIMITATIONS AND SERVICE CONSTRAINTS
i
DEFINITIONS
Accessible Material – any material to which access can be gained by any means other than significant destruction of building components, or, for the purposes of describing building occupant activities, a material subject to disturbance by routine use or maintenance activities.
ACM By Virtue of Contact – any material that is tested and found via laboratory analysis to be non-asbestos containing, but it is in contact with or applied using another material that is determined to contain asbestos. Since these materials cannot be separated during removal, the non-asbestos-containing material is now contaminated and will need to be disposed of as ACM. Some examples include: floor tile and associated mastic, linoleum sheeting and associated mastic, adhesive upon mastic application, etc.
AHERA – Asbestos Hazard Emergency Response Act
Asbestos – a generic name given to a number of naturally occurring hydrated mineral silicates that possess a unique crystalline structure, are incombustible in air, and are separable into fibers. Asbestos includes the asbestiform varieties of Chrysotile (Serpentine), Crocidolite (Riebeckite), Amosite (Cummingtonite-Grunerite), Anthophyllite, Tremolite, and Actinolite.
Asbestos-Containing Material (ACM) – any material or product which contains more than one percent asbestos.
Asbestos-Containing Building Material (ACBM) – means surfacing ACM, thermal system insulation ACM, or miscellaneous ACM that is found in or on interior structural members or other parts of a building.
Bulk Samples – samples of bulk material; in the case of asbestos, suspect material.
Chain-of-Custody – formal procedures for tracking samples and insuring their integrity.
DOT – United States Department of Transportation
Friable – the material, when dry, may be crumbled, pulverized, or reduced to powder by hand pressure, and includes previously non-friable material after such previously non-friable material becomes damaged to the extent that when dry it may be crumbled, pulverized, or reduced to powder by hand pressure.
Good Condition – as used in the context of material condition, integrity of the material is generally complete, with no visible damage or deterioration, or showing only very limited damage or deterioration. Possible small areas of delamination or indications of limited contact or damage. The mechanism to retain the insulation in its original position (e.g., cloth wrapping over pipe insulation) is still present.
Homogeneous Application – an application of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture, and vintage of application.
ii
NESHAP – National Emission Standard for Hazardous Air Pollutants
NIST – NVLAP – National Institute of Standards and Technology, National Voluntary Laboratory Accreditation Program
Operations and Maintenance (O&M) Program – a program of work practices to maintain friable ACBM in good condition, ensure cleanup of asbestos fibers previously released, and prevent further release by minimizing and controlling friable ACBM disturbance or damage. An O&M Program should be implemented at all buildings with ACM.
Optical Microscope – a microscope which uses the transmission of light through lenses to magnify a specimen for examination. Capable of resolution of fibers or other materials down to approximately
0.25 micrometers in diameter.
OSHA – United States Occupational Safety and Health Administration.
Polarized Light Microscopy (PLM) – an optical microscopic method for the identification of asbestos in bulk samples in which the sample is illuminated with polarized light (light which vibrates in only one plane) to distinguish between different types of asbestos fibers by their shape and unique optical properties.
USEPA - United States Environmental Protection Agency
VA – Department of Veterans Affairs
VAMC Wilkes-Barre – Veterans Affairs Medical Center – Wilkes-Barre iii
1.0 BACKGROUND
PARS Environmental, Inc. (PARS), under contract to the Veterans Affairs Medical Center – Wilkes-Barre (VAMC Wilkes-Barre), completed comprehensive asbestos surveys at the VAMC Wilkes-Barre complex in May 2014. The nine (9) buildings that comprise the VAMC Wilkes- Barre complex were included as part of the survey. The buildings were identified to PARS as the following:
• Building #1: Medical Center
• Building #3: Office Building
• Building #5: Office Building
• Building #8: CWT Residents
• Building #11: Boiler Room and Mezzanine
• Building #12: Engineering
• Building #17: Warehouse
• Building #27: Community Living Center
• Building #28: Emergency Generator
The comprehensive asbestos surveys were completed to locate and identify Homogenous Areas (HAs), identify the asbestos content of HAs, quantify asbestos HAs, assess the condition of HAs, assess the friability and risk of occupant exposure to existing asbestos materials, and provide cost estimates and priorities for damaged or compromised asbestos discovered during the surveys. The survey was completed following local, state, and federal laws, rules, and codes regarding asbestos including the United States Environmental Protection Agency (USEPA) Asbestos Hazard Emergency Response Act (AHERA, 40 CFR 763, Subpart E), USEPA Asbestos School Hazard Abatement Reauthorization Act (ASHARA, 1992), and the Occupational Safety and Health Administration (OSHA) asbestos regulations for general and construction industries (29 CFR 1910.1001 and 1926.1101, respectively).
2.0 INTRODUCTION
PARS Environmental, Inc. (PARS), under contract to the VAMC Wilkes-Barre, has prepared this Asbestos Survey Report for VAMC Wilkes-Barre Building #1 (“Site”).
The asbestos survey was performed by Mr. Julian Fernandez-Obregon and Mr. Cody Postlethwait of PARS. Mr. Fernandez-Obregon is certified as an Asbestos Building Inspector by the Commonwealth of Pennsylvania Department of Labor and Industry (Certification No.
051514) and was responsible for the technical aspects of the survey. Mr. Postlethwait is certified as a USEPA/AHERA Asbestos Building Inspector and assisted Mr. Fernandez- Obregon with non-technical aspects of the survey. Copies of their certifications are included in Appendix A.
The objective of the survey was to identify suspect asbestos-containing material (ACM) for potential removal prior to renovation/demolition activities impacting these materials. During the course of the work, PARS was only allowed to inspect accessible areas. Therefore, only
PARS Project No. 1040-01 limited access was obtained for destructive testing to identify materials which may be hidden or obstructed at the Site. Examples of concealed or obstructed areas include, but are not limited to, wall cavities, pipe chases, spaces above fixed ceilings, and equipment interiors.
The USEPA defines an ACM as a material that contains greater than one percent (>1%) asbestos. A list of applicable regulations of the local, state, and federal regulations governing asbestos are provided in Appendix B.
3.0 SITE DESCRIPTION
The Site encompasses approximately 498,533 square feet (SF) and is a thirteen-story facility referred to as the Main Hospital. The building is constructed with a steel-frame with a brick exterior. There are multiple roofs on this building, on several different levels, some having been replaced recently. Roofing materials vary from a newer rubber membrane roof, to an older, felt and stone covered roof. The interior finishes vary floor to floor, with varying amounts of concrete, carpet, and vinyl floors, ceiling tile of different types, and mostly plaster walls, but some with drywall and joint compound. The structure is primarily heated by a large multi-boiler plant on the basement level, identified as a separate building from the Main Hospital, with heat provided by radiators on most floors.
4.0 METHODOLOGY
PARS performed an asbestos survey at the VAMC Wilkes-Barre from May 5 through May 15, 2014. During that time, PARS completed its survey of the Site. The survey approach included a visual inspection of the suspect ACM. The survey included limited intrusive testing. PARS did not use destructive testing techniques in concealed or obstructed areas during the survey.
All accessible suspect materials were sampled regardless of previous results or age of material.
Suspect materials were divided into homogeneous areas, which are building materials evaluated by the inspectors to be the same based on their color, texture, and suspected age.
Representative samples were collected of each homogeneous material. Suspect materials identified and sampled in Building #1 are listed in Table 1. A photographic log of confirmed ACM is included in Appendix C.
Bulk samples of suspect materials were collected in 4-mil plastic bags and sealed for transport to the laboratory under chain-of-custody protocols. Each sample was assigned a unique homogeneous application number (e.g., M-1, M-2, S-1) and sample identification number (e.g., MH-13-1). If the laboratory identified layered materials in the sample submitted for analysis, for reporting purposes it was assigned the same sample number as the base sample; however, the corresponding homogenous application number and an “A” added (e.g., M-1A, S-1A).
The following are the homogeneous material symbols used for identification in this report:
T = Thermal System Insulation (TSI) M = Miscellaneous Materials S = Surfacing Materials (troweled or spray-applied)
4.1 ANALYTICAL METHODS
Laboratory analysis was conducted by International Asbestos Testing Laboratories, Inc. (IATL) located in Mount Laurel, New Jersey. IATL is certified by the National Institute of Standards and Technology and National Voluntary Laboratory Accreditation Program (NIST-NVLAP #100188) for asbestos analysis. Material identification was performed via Polarized Light Microscopy (PLM) using USEPA Method 600/R-93/116. Samples containing 10% or less of asbestos were also subject to the USEPA 400-point count method. Certifications for IATL are included in Appendix D.
4.2 FINDINGS
Based on the visual inspection performed by PARS, friable and non-friable suspect ACMs were identified at the Site. Below is a list of suspect ACMs that were identified and sampled. A total of 563 bulk samples were collected for analysis. Bulk asbestos sample results are summarized in Table 1 and the corresponding laboratory reports are included in Appendix E. Bulk sample chain-of-custodies are provided in Appendix F. Sample locations are depicted on included Figures.
The following materials are identified as suspect ACM during the survey:
• Floor Tiles (various patterns and sizes) and Associated Mastics
• Drywall and Associated Joint Compound
• Plaster (white and brown coats)
• Window Caulks and Glazing
• Roofing Materials
• Ceiling Tiles (various patterns and sizes) and Associated Mastics (where applicable)
• Fireproofing
• Vibration Dampeners
• Pipe Insulation and Associated Fittings (various diameters)
• Heat Shields
• Covebase and Associated Mastics
• Carpet Mastics
• Stair Treads and Associated Mastics
• Vinyl Floor Sheeting (various patterns) and Associated Mastics
• Wall Waterproofing
Laboratory analytical results indicate that the following identified and sampled suspect ACMs were determined to be asbestos-containing:
• M-8 Light Gray Caulking
• M-9 Black Caulking
• M-20 White Window Caulking
• M-24 12”x12” Beige w/Gray Spots Floor Tile (by virtue of association w/M-24B)
• M-24A Yellow Floor Tile Mastic Associated w/M-24 (by virtue of association w/M-24)
• M-24B Black Floor Tile Mastic Associated w/M-24
• M-28 Orange/Black Carpet Mastic
• M-29 12”x12” White w/Gray Spots Floor Tile (by virtue of association w/M-29A)
• M-29A Black Floor Tile Mastic Associated w/M-29
• M-30 9”x9” Green Floor Tile
• M-30A Black Floor Tile Mastic Associated w/M-30
• M-30B Yellow Mastic Associated w/M-30 (by virtue of association w/M-30)
• M-30C Tan Mastic Associated w/M-30 (by virtue of association w/M-30)
• M-31 9”x9” Tan Floor Tile (by virtue of association w/M-31A)
• M-31A Black Floor Tile Mastic Associated w/M-31 (by virtue of association w/M-31D)
• T-36 6” Pipe Insulation
• T-36A Cork Insulation Associated w/M-36 (by virtue of association w/M-36)
• T-37 Pipe Fitting Insulation Associated w/M-36
• T-37A Cork Insulation Associated w/M-37 (by virtue of association w/M-37)
• M-38 12”x12” White w/Beige Spots Floor Tile (by virtue of association w/M-38D)
• M-38D Black Mastic Associated w/M-38
• M -39 12”x12” Beige w/White Spots Floor Tile (by virtue of association w/M-39A)
• M-39A Black Floor Tile Mastic Associated w/M-39
• M-43 Black Floor Tile Mastic
• M-49 Cementitious Heat Shield
• M-53 9”x9” Brown Floor Tile
• M-53A Tan Mastic Associated w/M-53 (by virtue of association w/M-53B)
• M-53B Black Floor Tile Mastic Associated w/M-53
• M-54 12”x12” Beige w/Brown Streak Floor Tile
• M-54A Yellow/Black Mastic Associated w/M-54
• M-55 12”x12” Green w/Gray Spots Floor Tile
• M-55A Black Mastic Associated w/M-55
• M-56 12”x12” Light Beige w/Dark Spots Floor Tile (by virtue of association w/M-56A)
• M-56A Black Mastic Associated with M-56
• M-57 12”x12” Dark Beige w/Dark Spots Floor Tile (by virtue of association w/M-57A)
• M-57A Black Mastic Associated w/M-57
• M-63 12”x12” Light Mint w/Gray Spots Floor Tile
• M-63A Black Mastic Associated w/M-63
• M-64 12”x12” Light Gray w/Dark Gray Spots Floor Tile
• M-64A Black Mastic Associated w/M-64
• M-65 12”x12” Beige w/Brown Spots Floor Tile
• M-65A Black Mastic Associated w/M-65
• M-68 12”x12” Light Green w/Gray Spots Floor Tile
• M-68B Black Mastic Associated w/M-68
• M-71 12”x12” Green w/Dark Green Streaks Floor Tile
• M-71A Black Mastic Associated w/M-71
• M-72 12”x12” Tan w/Beige Spots Floor Tile
• M-72A Black Mastic Associated w/M-72
• M-81 12”x12” Green w/Olive Spots Floor Tile
• M-81A Black Mastic Associated with M-81
• T-83 12” Pipe Insulation
• T-83A Brown Cork Associated w/M-83 (by virtue of association w/M-83)
• M-84 9”x9” Black Floor Tile
• M-86 12”x12” Brown w/Tan Spots Floor Tile (by virtue of association w/M-86A)
• M-86A Black Mastic Associated w/M-86
• M-93 12”x12” White w/Gray Spots Floor Tile (by virtue of association w/M-93A)
• M-93A Tan/Black Mastic Associated w/M-93
• M-94 12”x12” Beige w/Brown Spots Floor Tile
• M-94A Black/Light Tan Mastic Associated w/M-94
• M-95 12”x12” Mint Floor Tile (by virtue of association w/M-95A)
• M-95A Black Mastic Associated w/M-95
• M-99 9”x9” White w/Blue Spots Floor Tile
• M-99A Black Mastic Associated w/M-99
• M-99B Brown Floor Tile Associated w/M-99
• M-100 12”x12” White w/Gray Spots Floor Tile (by virtue of association w/M-100B)
• M-100A Clear Mastic Associated w/M-100 (by virtue of association w/M-100B)
• M-100B Black Mastic Associated w/M-100
• M-104 12”x12” Black w/White Streaks Floor Tile
• M-107 12”x12” Tan w/Brown Spots Floor Tile
• M-107A Black Mastic Associated w/M-107
• M-115 12”x12” Off-White w/Gray Streaks Floor Tile
• M-115A Black Mastic Associated w/M-115
• S-117 Black Waterproofing/Vapor Barrier
• T-118 6” Pipe Insulation
• T-119 Pipe Fitting Insulation Associated w/6” Pipe
• T-120 3” Pipe Insulation
Per the contract documents, asbestos identified in a bulk sample equal to or above trace quantities shall be reported as ACM. The following materials were identified with equal to or above trace quantities of asbestos and are also considered ACM:
• M-52 White/Yellow Carpet Mastic
• M-59 12”x12” White w/Gray Streaks Floor Tile (by virtue of association w/M-59A)
• M-59B Black Mastic Associated w/M-59
• M-82 12”x12” White w/Beige Spots Floor Tile (by virtue of association w/M-82A)
• M-82A Black/Tan Mastic Associated with M-82
• M-109 12”x12” Beige w/White Streaks Floor Tile
• M-109A Black Mastic Associated w/M-109
PARS Project No. 1040-01
The identified ACMs were noted to be in good condition (i.e., no visible damage or deterioration or showing only very limited damage or deterioration) with the exception of pipe insulation and associated pipe fittings located within the basement level construction area in the west wing (Homogenous Areas S-117, T-118, T-119, T-120).
Destructive testing methods to access concealed and obstructed areas were not employed as part of the survey. Limitations and service constraints are discussed in Appendix G.
4.3 SURVEY OBSERVATIONS
Several homogenous areas were created that spanned several floors, with a minimum of one (1) sample collected per floor for the respective homogenous area. However, lab analysis created a subset of certain homogenous areas, as is the case for M-38 (12” x 12” White Floor Tiles with Beige Spots). The first samples collected on the tenth floor were associated with a yellow and black mastic combination, as determined by the laboratory split, with these samples analyzed showing no asbestos. The same floor tiles were observed on the basement and first floor with mastic that was analyzed positive by the laboratory. Although both share a homogenous area, as the tiles are identical, the underlying mastic is positive on the lower floors, but negative on the upper floors. This allows a split within a homogenous area, as the mastics analyzed by the laboratory showed different results. The homogenous area is not universally identified as ACM, only the area with the mastic confirmed as ACM by the laboratory. This case is observed in several instances, where the mastic is positive for one homogenous area of floor tiles, but in another area with the same tiles where different analytical results for the mastic are identified.
Regarding TSI, confirmed ACM pipe runs were found in the mechanical rooms on the east and west wings, and elevator shaft mechanical rooms of most floors. Suspect pipe insulation above the drop ceiling was only observed on the fourth and tenth floors. The overhead pipes on the other floors were observed to be fiberglass pipe insulation, and not suspect ACM. From the fifth floor down to the basement, in the north wing, suspect pipe insulation was observed and sampled, again remaining contained to a single mechanical shaft, and not branching out above the drop ceiling. Sub-wall pipe insulation was visible only in the basement west wing construction area, where most walls were open and interstitial spaces were exposed for renovation.
5.0 CONCLUSIONS AND RECOMMENDATIONS
Based on the findings of the survey, ACM was identified in Building #1. The identified ACMs, detailed in Section 4.2, were noted to be in good condition (i.e., no visible damage or deterioration or showing only very limited damage or deterioration) with the exception of referenced pipe insulation and associated pipe fittings located within the basement level construction area in the west wing.
PARS Project No. 1040-01
Damaged ACM located within the basement level construction area in the west wing should be removed by a Pennsylvania licensed asbestos contractor with appropriate air monitoring and oversight. Renovation in this area should not proceed until the damaged ACM has been removed and air clearance has been achieved. The damaged ACM included:
• S-117 Black Waterproofing/Vapor Barrier
• T-118 6” Pipe Insulation
• T-119 Pipe Fitting Insulation Associated w/6” Pipe
• T-120 3” Pipe Insulation
All ACM should be removed by a Pennsylvania licensed asbestos contractor prior to renovation or demolition activities impacting these materials. For ACM in good condition that will remain in-place, an operations and maintenance (O&M) program should be developed. The O&M program will define work practices, training requirements, and management procedures designed to maintain the ACM in good condition.
If suspect ACM not referenced in this report is identified in concealed or obstructed areas during renovation and/or demolition activities, it is recommended that the activities that will disturb these materials cease and the materials be sampled and analyzed to assess the potential presence of asbestos. Cost estimates for abatement of the damaged ACM is provided in Table 2.
-o0o-
This report has been reviewed by and is certified as accurate by the undersigned Commonwealth of Pennsylvania Department of Labor and Industry Asbestos Project Designer.
PARS appreciates the opportunity to assist the Department of Veterans Affairs and the VAMC Wilkes-Barre with this project. Should you have any questions or comments please feel free to contact us at (609) 890-7277.
Respectfully submitted, PARS ENVIRONMENTAL, INC.
Rafael L. Torres, III Margaret Halasnik Senior Industrial Hygienist Principal Industrial Hygienist Pennsylvania Licensed Project Designer Certification #030202
FIGURES
SAMPLE LOCATION MAPS
TABLE 1
HOMOGENEOUS APPLICATION TABLE
Homogeneous Application Table
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-1 MH-13-1, 2, 3 Window Caulking Chlorine Tank Room 20LF G 12% Chrysotile
M-2 MH-13-4, 5, 6 2x2 Pinhole Ceiling Tile Server Room 4SF G NAD
M-2 MH-10-151, 152, 153 2x2 Pinhole Ceiling Tile 10th Floor Near Blue Elevators 1500SF G NAD
M-2 MH-9-167 2x2 Pinhole Ceiling Tile 9th Floor 2000SF G NAD
M-2 MH-5-311 2x2 Pinhole Ceiling Tile 5th Floor 10000SF G NAD
M-2 MH-3-367 2x2 Pinhole Ceiling Tile 3rd Floor 20000SF G NAD
M-3 MH-13-7, 8, 9 Caulking, Red Server Room 8LF G NAD
M-3 MH-12-48 Caulking, Red 12th Floor Mechanical Room 10LF G NAD
M-3 MH-10-126 Caulking, Red C10-06 10SF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-3 MH-5-301 Caulking, Red C5-71a 20LF G NAD
M-4 MH-13-10, 11, 12 Caulking, Light Red Chlorine Tank Room 4SF G NAD
M-4 MH-12-49 Caulking, Light Red 12th Floor Mechanical Room 35LF G NAD
M-4 MH-S2-74 Caulking, Light Red Stairwell 2 5LF G NAD
M-5 MH-13-13, 14, 15 Caulking, Red/Black Chlorine Tank Room 1SF G NAD
M-6 MH-13-16, 17, 18 Caulking, Gray Chlorine Tank Room 1SF G NAD
M-7 MH-13-19, 20, 21 Drywall Chlorine Tank Room, Server Room
500SF G NAD
M-7 MH-11-99, 100, 101 Drywall C-11-21 12SF G NAD
M-7 MH-10-145 Drywall 10th Floor 5000SF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-7 MH-9-174 Drywall C9-39 50SF G NAD
M-7 MH-8-190 Drywall 8th Floor 200SF G NAD
M-7 MH-5-310 Drywall 5th Floor 2000SF G NAD
M-7 MH-2-401 Drywall 2nd Floor Front Wing 20000SF G NAD
M-7 MH-1-450 Drywall 1st Floor 5000SF G NAD
M-7 MH-B-549 Drywall Basement 1000SF G NAD
M-7A MH-B-549 Lab Split, Light Tan Floor Tile Basement N/A N/A NAD
M-8 MH-S3-22, 23, 24 Caulking, Light Gray Stairwell 3 1LF G 6.3% Chrysotile
M-9 MH-S3-25, 26, 27 Caulking, Black Stairwell 3 1LF G 9.3% Chrysotile
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-10 MH-S3-28, 29, 30 Wall Filler, Black Stairwell 3 1LF G NAD
M-11 MH-13-31, 32, 33, 34, 35 Spray-On Fireproofing Room 130002-1 1000SF G NAD
M-11 MH-S5-157, 158, 159 Spray-On Fireproofing Stairwell 5 Mechanical Room @ 11th Floor
650SF G NAD
M-11
MH-8-203, 204, 205, 233,
Spray-On Fireproofing Service Elevator Area, C8-49B, C, C8-21, C8-70D
2000SF G NAD
M-11 MH-7-238, 239, 240 Spray-On Fireproofing A7-68, C7-69D 1000SF G NAD
M-11
MH-6-281, 282, 283, 284,
Spray-On Fireproofing C6-67D 1500SF G NAD
M-11
MH-4-334, 335, 336, 337,
Spray-On Fireproofing C4-49B, C, A4-03 1000SF G NAD
M-11
MH-3-384, 385, 386, 387,
Spray-On Fireproofing C3-50A 1000SF G NAD
M-11 MH-1-451, 452, 453 Spray-On Fireproofing 1st Floor 1500SF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-11
MH-1-482, 483, 484, 485,
Spray-On Fireproofing C1-47 1000SF G NAD
M-12 MH-S3-36, 37, 38 Vibration Dampener, Black 12th Floor Mechanical Room 20LF G NAD
M-13 MH-S3-39, 40, 41 Vibration Dampener, White 12th Floor Mechanical Room 30LF G NAD
M-14 MH-S3-42, 43, 44 Pipe Insulation, White/Black 12th Floor Mechanical Room 30LF G NAD
M-15 MH-S3-45, 46, 47 Caulking, Dark Gray 12th Floor Mechanical Room 20LF G NAD
M-16 MH-12-50, 51, 52 Roofing Tar, Black 12th Floor Roof 15LF G NAD
M-17 MH-12-53, 54, 55 Roofing Caulk, Black 12th Floor Roof 300LF G NAD
M-17 MH-11-160, 161, 162 Roofing Caulk, Black 11th Floor Roof 100LF G NAD
M-18 MH-12-56, 57, 58 Roofing Caulk, White 12th Floor Roof 150LF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-18A MH-12-57 Lab Split, Roofing Caulk, Gray 12th Floor Roof N/A N/A NAD
M-19 MH-12-59, 60, 61 Roofing Sealant, White 12th Floor Roof 150LF G NAD
M-19A MH-12-59 Lab Split, Roofing Tar, Black 12th Floor Roof N/A N/A NAD
M-20 MH-12-62, 63, 64 Window Caulk, White Stairwell 3 200LF G 1.3% Chrysotile
M-21 MH-12-65, 66, 67 Roofing Caulk, Gray 12th Floor Roof 55LF G NAD
M-22 MH-12-68, 69-70 Door Caulking, Tan 12th Floor Roof 50LF G NAD
M-23 MH-S3-71, 72, 73 Window Glazing Stairwell 3 5LF G NAD
M-24 MH-11-75, 76, 77
12x12 Beige Floor Tiles w/Gray Spots
11th Floor Hallway 6000SF G NAD*
M-24A MH-11-76 Lab Split, Yellow Mastic 11th Floor Hallway 6000SF G NAD*
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-24B MH-11-77 Lab Split, Black Mastic 11th Floor Hallway 6000SF G 13.8% Chrysotile
M-24 MH-8-191
12x12 Beige Floor Tiles w/Gray Spots
8th Floor 20000SF G 1.4% Chrysotile
M-24A MH-8-191 Lab Split, Yellow/Black Mastic 8th Floor 20000SF G 1.6% Chrysotile
M-24 MH-7-260
12x12 Beige Floor Tiles w/Gray Spots
Service Elevator Area 2000SF G NAD**
M-24A MH-7-260 Lab Split, Black Mastic Service Elevator Area N/A N/A NAD**
M-24 MH-6-274
12x12 Beige Floor Tiles w/Gray Spots
C6-45 2000SF G NAD
M-24B MH-6-274 Lab Split, Tan Mastic C6-45 2000SF G NAD
M-25 MH-11-78, 79, 80 Baseboard Ahesive, Brown C-11-11, Throughout 11th Floor 150SF G NAD
M-25A MH-11-78, 80
Lab Split, Off-White Joint Compound
C-11-11, Throughout 11th Floor N/A N/A NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-25B MH-11-79 Lab Split, Green Joint Compound C-11-11, Throughout 11th Floor N/A N/A NAD
S-26 MH-11-81, 82, 83 Plaster, Whitecoat 11th Floor N/A G NAD
S-26A MH-11-81, 83 Lab Split, Plaster, Browncoat 11th Floor N/A G NAD
S-26B MH-11-82 Lab Split, Tan Mastic 11th Floor N/A N/A NAD
S-26 MH-10-136, 137, 138 Plaster, Whitecoat 10th Floor N/A G NAD
S-26A MH-10-136, 137, 138 Lab Split, Plaster, Browncoat 10th Floor N/A G NAD
S-26 MH-9-164, 165, 166 Plaster, Whitecoat 9th Floor N/A G NAD
S-26A MH-9-164, 165, 166 Lab Split, Plaster, Browncoat 9th Floor N/A G NAD
S-26 MH-8-199, 200, 201, 202 Plaster, Whitecoat 8th Floor N/A G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
S-26A MH-8-199, 200, 201, 202 Lab Split, Plaster, Browncoat 8th Floor N/A G NAD
M-26 MH-7-242, 243, 244, 245 Plaster, Whitecoat 7th Floor N/A G NAD
M-26A MH-7-242, 243, 244, 245 Lab Split, Plaster, Browncoat 7th Floor N/A G NAD
M-26 MH-6-266, 267, 268, 269 Plaster, Whitecoat 6th Floor N/A G NAD
M-26A MH-6-266, 267, 268, 269 Lab Split, Plaster, Browncoat 6th Floor N/A G NAD
S-26
MH-5-295, 296, 297, 298,
Plaster, Whitecoat 5th Floor N/A G NAD
S-26A
MH-5-295, 296, 297, 298,
Lab Split, Plaster, Browncoat 5th Floor N/A G NAD
S-26 MH-4-323, 324, 325 Plaster, Whitecoat 4th Floor N/A G NAD
S-26A MH-4-323, 324, 325 Lab Split, Plaster, Browncoat 4th Floor N/A G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
S-26
MH-3-368, 369, 370, 371,
372, 373
Plaster, Whitecoat 3rd Floor N/A G NAD
S-26A
MH-3-368, 369, 370, 371,
372, 373
Lab Split, Plaster, Browncoat 3rd Floor N/A G NAD
S-26
MH-2-395, 396, 397, 398,
399, 400
Plaster, Whitecoat 2nd Floor N/A G NAD
S-26A
MH-2-395, 396, 397, 398,
399, 400
Lab Split, Plaster, Browncoat 2nd Floor N/A G NAD
S-26
MH-1-442, 443, 444, 445,
446, 447, 448
Plaster, Whitecoat 1st Floor N/A G NAD
S-26A
MH-1-442, 443, 444, 445,
446, 447, 448
Lab Split, Plaster, Browncoat 1st Floor N/A G NAD
S-26
MH-B-506, 507, 508, 509,
510, 511, 512
Plaster, Whitecoat Basement N/A G NAD
S-26A
MH-B-506, 507, 508, 509,
510, 511, 512
Lab Split, Plaster, Browncoat Basement N/A G NAD
M-27 MH-11-84, 85, 86 Carpet Mastic, Yellow C-11-11, 13 600SF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-28 MH-11-87, 88, 89 Carpet Mastic, Orange/Black C-11-30A, 16, 23 1250SF G 3% Chrysotile
M-29 MH-11-90, 91, 92
12x12 White Floor Tiles w/Gray Spots
C-11-13A 150SF G NAD*
M-29A MH-11-90, 91, 92 Lab Split, Black Mastic C-11-13A 150SF G 4.8% Chrysotile
M-30 MH-11-93, 94, 95 9x9 Green Floor Tile C-11-23 350SF G 7.5% Chrysotile
M-30A MH-11-93, 94, 95 Lab Split, Black Mastic C-11-23 350SF G 16.3% Chrysotile
M-30B MH-11-93, 94, 95 Lab Split, Yellow Mastic C-11-23 N/A N/A NAD*
M-30 MH-4-319, 320, 321 9x9 Green Floor Tile C4-132 500SF G 2.1% Chrysotile
M-30A MH-4-319 Lab Split, Black Mastic C4-132 500SF G 1.8% Chrysotile
M-30C MH-4-319, 320, 321 Lab Split, Tan Mastic C4-132 500SF G NAD*
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-31 MH-11-96, 97, 98 9x9 Tan Floor Tile C-11-22 350SF G NAD
M-31A MH-11-96, 97, 98 Lab Split, Tan Mastic C-11-22 N/A N/A NAD
M-31B MH-11-96 Lab Split, Yellow Mastic C-11-22 N/A N/A NAD
M-31C MH-11-97, 98 Lab Split, Yellow/Gray Mastic C-11-22 N/A N/A NAD
M-31 MH-8-221, 222, 223 9x9 Tan Floor Tile C8-33 100SF G NAD*
M-31D MH-8-221 Lab Split, Black Mastic C8-33 100SF G 1.5% Chrysotile
M-32 MH-11-102, 103, 104 Baseboard Adhesive, Tan C-11-19 5SF G NAD
M-32 MH-9-178 Baseboard Adhesive, Tan 9th Floor 20LF G NAD
M-33 MH-11-104, 105, 106 2x4 Fissure Ceiling Tile 11th Floor 3000SF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-33 MH-10-125 2x4 Fissure Ceiling Tile 10th Floor 15000SF G NAD
M-33 MH-8-198 2x4 Fissure Ceiling Tile 8th Floor 20000SF G NAD
M-33 MH-6-265 2x4 Fissure Ceiling Tile 6th Floor 15000SF G NAD
M-33 MH-5-288 2x4 Fissure Ceiling Tile 5th Floor 25000SF G NAD
M-33 MH-3-374 2x4 Fissure Ceiling Tile 3rd Floor 20000SF G NAD
M-33 MH-1-449 2x4 Fissure Ceiling Tile 1st Floor 25000SF G NAD
M-34 MH-11-107, 108, 109 2x4 Pinhole Ceiling Tile 11th Floor 1000SF G NAD
M-34 MH-5-309 2x4 Pinhole Ceiling Tile 5th Floor 10000SF G NAD
M-34 MH-8-189 2x4 Pinhole Ceiling Tile 8th Floor 10000SF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-35 MH-11-110, 111, 112 2x4 Random Ceiling Tile 11th Floor 2000SF G NAD
M-35 MH-B-520 2x4 Random Ceiling Tile Basement 1000SF G NAD
T-36 MH-11-113, 114, 115 TSI 6" Pipe Wrap, Black Mechanical Room near Elevators
10LF/Floor G 1.3% Chrysotile
T-36 MH-10-146 TSI 6" Pipe Wrap, Black 10th Floor Hallway 100LF G 3.2% Chrysotile
T-36A MH-10-146 Lab Split, Brown Cork 10th Floor Hallway N/A N/A NAD*
T-36 MH-9-184 TSI 6" Pipe Wrap, Black C9-27 20LF G NAD**
T-36A MH-9-184 Lab Split, Brown Cork C9-27 N/A N/A NAD**
T-36 MH-4-313 TSI 6" Pipe Wrap, Black C4-73 G NAD**
T-36A MH-4-313 Lab Split, Brown Cork C4-73 N/A N/A NAD**
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
T-36 MH-2-427 TSI 6" Pipe Wrap, Black Mechanical Closet Near Stairwell 1
G 2.8% Chrysotile
T-36A MH-2-427 Lab Split, Brown Cork Mechanical Closet Near Stairwell 1
G NAD*
T-37 MH-11-116, 117, 118 TSI Elbows A/W 6" Pipe Mechanical Room near Elevators
1LF/ea G NAD**
T-37 MH-10-147 TSI Elbows A/W 6" Pipe 10th Floor Hallway 5SF G 2.8% Chrysotile
T-37A MH-10-147 Lab Split, Brown Cork 10th Floor Hallway N/A N/A NAD*
T-37 MH-4-314 TSI Elbows A/W 6" Pipe C4-73 NAD**
T-37A MH-4-314 Lab Split, Brown Cork C4-73 N/A N/A NAD**
T-37 MH-2-428 TSI Elbows A/W 6" Pipe Mechanical Closet Near Stairwell 1
G NAD**
T-37B MH-2-428 Lab Split, Black Tar Mechanical Closet Near Stairwell 1
G NAD**
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
T-37 MH-1-459, 460, 461 TSI Elbows A/W 6" Pipe N1-86, Everywhere above 400LF G 3.8% Chrysotile
M-38 MH-10-119, 120, 121
12x12 White Floor Tile w/Beige Spots
10th Floor Throughout 17000SF G NAD
M-38A MH-10-120 Lab Split, Yellow/Black Mastic 10th Floor Throughout N/A N/A NAD
M-38B MH-10-120
Lab Split, Off-White Leveling Compound
10th Floor Throughout N/A N/A NAD
M-38C MH-10-121 Lab Split, Black Mastic 10th Floor Throughout N/A N/A NAD
M-38 MH-9-185
12x12 White Floor Tile w/Beige Spots
C9-23 100SF G NAD**
M-38 MH-1-454, 467, 468
12x12 White Floor Tile w/Beige Spots
N1-86, 100 hallway, main hallway
20000SF G NAD*
M-38D MH-1-454 Lab Split, Tan/Black Mastic N1-86, 100 hallway, main hallway
20000SF G 1.3% Chrysotile
M-38 MH-B-513, 514, 515
12x12 White Floor Tile w/Beige Spots
Basement Hallway, CB-10, Front Wing Hallway and Offices
20000SF G NAD*
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-38D MH-B-513 Lab Split, Black Mastic Basement Hallway, CB-10, Front Wing Hallway and Offices
20000SF G 4.3% Chrysotile
M-39 MH-10-122, 123, 124
12x12 Beige Floor Tile w/White Spots
10th Floor Throughout 4000SF G NAD
M-39B MH-10-122, 124 Lab Split, Yellow Mastic 10th Floor Throughout N/A N/A NAD
M-39 MH-S5-163
12x12 Beige Floor Tile w/White Spots
Stairwell 5 1200SF G NAD
M-39 MH-9-183
12x12 Beige Floor Tile w/White Spots
9th Floor 10000SF G NAD
M-39B MH-9-183 Lab Split, Tan Mastic 9th Floor N/A NAD
M-39C MH-9-183 Lab Split, Yellow Mastic 9th Floor N/A NAD
M-39 MH-7-241
12x12 Beige Floor Tile w/White Spots
7th Floor 20000SF G NAD
M-39C MH-7-241 Lab Split, Yellow Mastic 7th Floor N/A N/A NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-39 MH-6-286
12x12 Beige Floor Tile w/White Spots
FMSS, Near C6-67B 1500SF G NAD
M-39B MH-6-286 Lab Split, Tan Mastic FMSS, Near C6-67B 1500SF G NAD
M-39 MH-6-287
12x12 Beige Floor Tile w/White Spots
Near Stairwell 5 1500SF G NAD
M-39D MH-6-287
Lab Split, Light Gray/Yellow/Grey Mastic/Leveling Compound
Near Stairwell 5 1500SF G NAD
M-39 MH-5-305
12x12 Beige Floor Tile w/White Spots
5th Floor 20000SF G NAD*
M-39A MH-5-305A Lab Split, Black Mastic 5th Floor 20000SF G 1.5% Chrysotile
M-39 MH-4-315
12x12 Beige Floor Tile w/White Spots
4th Floor 25000SF G NAD*
M-39A MH-4-315 Lab Split, Light Tan/Black Mastic 4th Floor 25000SF G 1.3% Chrysotile
M-39 MH-3-366
12x12 Beige Floor Tile w/White Spots
3rd Floor 25000SF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-39C MH-3-366 Lab Split, Yellow Mastic 3rd Floor 25000SF G NAD
M-39 MH-2-402
12x12 Beige Floor Tile w/White Spots
2nd Floor Front Wing 15000SF G NAD
M-39C MH-2-402 Lab Split, Yellow Mastic 2nd Floor Front Wing 15000SF G NAD
M-39 MH-2-423
12x12 Beige Floor Tile w/White Spots
C2-39, Exam Rooms 4000SF G NAD
M-39D MH-2-423 Lab Split, Off White Mastic C2-39, Exam Rooms 4000SF G NAD
M-39 MH-1-466
12x12 Beige Floor Tile w/White Spots
Exam Rooms West Wing, Service Elevator Area West
20000SF G NAD**
M-39 MH-B-516
12x12 Beige Floor Tile w/White Spots
Basement Hallway, EMT Offices, Kitchen Offices
5000SF G NAD**
M-40 MH-10-127, 128, 129 Joint Compound, White C10-06 20SF G NAD
M-41 MH-10-130, 131, 132 Caulking, White C10-06 20LF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-42 MH-10-133, 134, 135 Window Caulking, Gray C-10-01 4LF/Window G NAD
M-43 MH-10-139, 140, 141 Floor Mastic, Black C10-31 200SF G 1.4% Chrysotile
M-43 MH-9-179 Floor Mastic, Black C9-43 400SF G 1.6% Chrysotile
M-43 MH-6-270 Floor Mastic, Black C6-24 400SF G 3% Chrysotile
M-44 MH-10-142, 143, 144 Caulking, Dark Red C10-28 5SF G NAD
M-44 MH-5-300 Caulking, Dark Red C5-71a 20LF G NAD
M-45 MH-10-148, 149, 150 Baseboard Adhesive, Yellow 10th Floor 2500LF G NAD
M-46 MH-S5-154, 155, 156 Stair Tread Mastic, Yellow Stairwell 5 80SF x11 G NAD
M-47 MH-9-168, 169, 170 Carpet Mastic, Blue C9-39, 40 500SF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-47 MH-2-409, 410, 411 Carpet Mastic, Blue 2nd Floor Lobby 2000SF G NAD
M-48 MH-9-171, 172, 173 2x2 Fissure Ceiling Tile C9-39 50SF G NAD
M-49 MH-9-175, 176, 177 Transite Heat Shield Throughout 4SF/each G 20% Chrysotile
M-50 MH-9-180, 181, 182 12x12 Blue Floor Tile 9th Floor 1000SF G NAD
M-50A MH-9-180 Lab Split, White Joint Compound 9th Floor N/A N/A NAD
M-50 MH-B-497, 498, 499 12x12 Blue Floor Tile CB-10 500SF G NAD
M-51 MH-9-186, 187, 188 12x12 Dark Blue Floor Tile C9-11, 46 400SF G NAD
M-52 MH-8-192, 193, 194 Carpet Mastic, White/Yellow C8-59, 57 400 SF G Trace Chrysotile
M-53 MH-8-195, 196, 197 9x9 Brown Floor Tile C8-58 250SF G 2.2% Chrysotile
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-53A MH-8-195, 196, 197 Lab Split, Tan Mastic C8-58 250SF G NAD*
M-53B MH-8-195 Lab Split, Black Mastic C8-58 250SF G 1.5% Chrysotile
M-54 MH-8-206, 207, 208
12x12 Beige Floor Tile w/Brown Streaks
C8-26, 27, 49 750SF G 1.4% Chrysotile
M-54A MH-8-206 Lab Split, Yellow/Black Mastic C8-26, 27, 49 750SF G 1.2% Chrysotile
M-55 MH-8-209, 210, 211
12x12 Green Floor Tiles w/Gray Spots
C8-50 1000SF G 1.5% Chrysotile
M-55A MH-8-209 Lab Split, Black Mastic C8-50 1000SF G 1.3% Chrysotile
M-55 MH-7-246
12x12 Green Floor Tiles w/Gray Spots
7th Floor 20000SF G 1.2% Chrysotile
M-55A MH-7-246 Lab Split, Black Mastic 7th Floor 20000SF G 1.6% Chrysotile
M-56 MH-8-212, 213, 214 12x12 Light Beige w/Dark Spots C8-50 40SF G NAD*
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-56A MH-8-212 Lab Split, Tan/Black Mastic C8-50 40SF G 1.3% Chrysotile
M-56 MH-B-531 12x12 Light Beige w/Dark Spots EB-38C Access Ramp 100SF G NAD**
M-57 MH-8-215, 216, 217 12x12 Dark Beige w/Dark Spots C8-50 40SF G NAD*
M-57A MH-8-215 Lab Split, Tan/Black Mastic C8-50 40SF G 1.4% Chrysotile
M-57 MH-B-532 12x12 Dark Beige w/Dark Spots EB-38C Access Ramp 100SF G NAD**
M-57A MH-B-532A Lab Split, Black Mastic EB-38C Access Ramp 100SF G NAD**
M-58 MH-8-218, 219, 220 Baseboard Adhesive, Peanut C8-50 100LF G NAD
M-59 MH-8-224, 225, 226
12x12 White Floor Tile w/Gray Streaks
C8-43 150SF G Trace Chrysotile
M-59A MH-8-224
Lab Split, Black/Grey Mastic/Leveling Compound
C8-43 150SF G 1.5% Chrysotile
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-59 MH-7-247
12x12 White Floor Tile w/Gray Streaks
C7-67 150SF G Trace Chrysotile
M-59B MH-7-247 Lab Split, Black Mastic C7-67 150SF G 1.4% Chrysotile
M-59 MH-5-312
12x12 White Floor Tile w/Gray Streaks
Service Elevator Area 600SF G NAD**
M-59B MH-5-312 Lab Split, Black Mastic Service Elevator Area 600SF G NAD**
M-59C MH-5-312 Lab Split, Black Felt Service Elevator Area N/A N/A NAD*
M-60 MH-8-227, 228, 229 Baseboard Adhesive, Brown C8-43 100LF G NAD
M-60 MH-7-261 Baseboard Adhesive, Brown 7th Floor 100LF G NAD
M-60A MH-7-261 Lab Split, Black Cove Base 7th Floor N/A N/A NAD
M-60 MH-3-360, 361, 362 Baseboard Adhesive, Brown 3rd Floor Front Wing 100LF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-60B MH-3-360, 361, 362 Lab Split, Brown Baseboard 3rd Floor Front Wing 100LF G NAD
M-61 MH-8-230, 231, 232
12x12 Tan Floor Tile w/BrownSpots
C8-45 250SF G NAD
M-61A MH-8-230, 231, 232 Lab Split, Black Mastic C8-45 N/A N/A NAD
M-62 MH-8-235, 236, 237 Linoleum, Gray 8th Floor 2000SF G NAD
M-62 MH-3-429, 430, 431 Linoleum, Gray 3rd Floor Construction, west-most rooms
5000SF G NAD
M-63 MH-7-248, 249, 250
12x12 Light Mint Tiles w/Gray Spots
C7-18 500SF G 1.3% Chrysotile
M-63A MH-7-248 Lab Split, Black Mastic C7-18 500SF G 1.8% Chrysotile
M-64 MH-7-251, 252, 253
12x12 Light Gray Floor Tile w/Dark Gray Spots
C7-63, 65 500SF G NAD*
M-64A MH-7-251, 252 Lab Split, Black Mastic C7-63, 65 500SF G 1.3% Chrysotile
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-65 MH-7-254, 255, 256
12x12 Beige Floor Tiles w/Brown Spots
7th Floor 15000SF G NAD*
M-65A MH-7-254 Lab Split, Black Mastic 7th Floor 15000SF G 2.7% Chrysotile
M-66 MH-7-257, 258, 259 Carpet Mastic, Light Brown C7-52 300SF G NAD
M-67 MH-7-262, 263, 264
12x12 White Floor Tile w/Blue Spots
C7-38 1000SF G NAD
M-67 MH-B-528, 529, 530
12x12 White Floor Tile w/Blue Spots
EB-45, 38, 41 1500SF NAD
M-67A MH-B-528, 529, 530 Lab Split, Black Mastic EB-45, 38, 41 1500SF NAD
M-68 MH-6-271, 272, 273
12x12 Light Green Floor Tile w/Gray Spots
6th Floor 20000SF G 2.5% Chrysotile
M-68A MH-6-271 Lab Split, Tan Leveling Compound 6th Floor N/A G NAD*
M-68B MH-6-272 Lab Split, Black Mastic 6th Floor 20000SF G 3.1% Chrysotile
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-68 MH-4-322
12x12 Light Green Floor Tile w/Gray Spots
C4-131 150SF G NAD**
M-68C MH-4-322 Lab Split, Tan Mastic C4-131 150SF G NAD**
M-69 MH-6-275, 276, 277
12x12 White Floor Tiles w/Brown Spots
6th Floor, New Side 15000SF G NAD
M-70 MH-6-278, 279, 280 Carpet Mastic, Orange 6th Floor, New Side 7000SF G NAD
M-70 MH-1-473, 474, 475 Carpet Mastic, Orange C1-23, 54 500SF G NAD
M-71 MH-5-289, 290, 291
12x12 Green Floor Tile w/Dark Green Streaks
5th Floor 25000SF G 1.4% Chrysotile
M-71A MH-5-289 Lab Split, Black Mastic 5th Floor 25000SF G 1.6% Chrysotile
M-72 MH-5-292, 293, 294
12x12 Tan Floor Tile w/Beige Spots
C5-65, C5-05, 6, 7 2500SF G 1.2% Chrysotile
M-72A MH-5-292 Lab Split, Black Mastic C5-65, C5-05, 6, 7 2500SF G 1.4% Chrysotile
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-73 MH-5-302, 303, 304
12x12 Gray Floor Tiles w/White Spots
Media Room Hall, C5-01b 600SF G NAD
M-73A MH-5-304 Lab Split, Yellow Mastic Media Room Hall, C5-01b 600SF G NAD
M-74 MH-5-306, 307, 308
12x12 Pink Floor Tile w/Dark Pink Spots
5th Floor 5000SF G NAD
M-75 MH-4-316, 317, 318
12x12 White Floor Tile w/Gray Spots
4th Floor 5000SF G NAD
M-76 MH-4-328, 329, 330
12x12 Green Floor Tile w/White Spots
Service Elevator Area 300SF G NAD
M-76A MH-4-328 Lab Split, Black Mastic Service Elevator Area 300SF G NAD
M-77 MH-4-331, 332, 333
12x12 Light Green Floor Tile w/White Spots
C4-51E 200SF G NAD
M-77A MH-4-331, 332, 333 Lab Split, Yellow/Blue Mastic C4-51E 200SF G NAD
M-78 MH-4-339, 340, 341 12x12 Salmon Floor Tile Nurses' Office Area, C4-49-51 5000SF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-78A MH-4-339, 340 Lab Split, Yellow Mastic Nurses' Office Area, C4-49-51 5000SF G NAD
M-79 MH-4-342, 343, 344
12x12 Gray Floor Tile w/White Spots
Nurses' Area Front Desk, OR Offices
3000SF G NAD
M-79A MH-4-342, 344 Lab Split, Tan/Blue Mastic Nurses' Area Front Desk, OR Offices
3000SF G NAD
M-79B MH-4-343 Lab Split, Yellow Mastic Nurses' Area Front Desk, OR Offices
3000SF G NAD
M-80 MH-4-345, 346, 347
12x12 White Floor Tile w/Green and Red Spots
4th Floor West Wing 25000SF G NAD
M-80A MH-4-345 Lab Split, Black Mastic 4th Floor West Wing N/A NAD
M-80B MH-4-346, 347
Lab Split, White/Gray Mastic/Leveling Compound
4th Floor West Wing N/A NAD
M-81 MH-3-348, 349, 350
12x12 Green Floor Tile w/Olive Spots
3rd Floor Front and West wing, C3-30
20000SF G 1.4% Chrysotile
M-81A MH-3-348 Lab Split, Black Mastic 3rd Floor Front and West wing, C3-30
20000SF G 1.6% Chrysotile
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-81 MH-2-418
12x12 Green Floor Tile w/Olive Spots
Radiology Wing Hallway, N2- 80, 79, 84, Service Elevator Area, West Wing
25000SF G 1.6% Chrysotile
M-81 MH-B-527
12x12 Green Floor Tile w/Olive Spots
CB-28 300SF G Trace Chrysotile
M-81A MH-B-527 Lab Split, Black Mastic CB-28 300SF G NAD**
M-82 MH-3-351, 352, 353
12x12 White Floor Tiles w/Beige Spots
N3-103, 104, 96, 105, 106, 92, 110, 114
5000SF G NAD*
M-82A MH-3-351, 353 Lab Split, Tan/Black Mastic N3-103, 104, 96, 105, 106, 92, 110, 114
5000SF G Trace Chrysotile
T-83 MH-5-354, 355, 356 TSI 12" Pipe Wrap, Black 5th Floor Front Wing Mechanical Room
150LF G 1.3% Chrysotile
T-83A MH-5-354, 355, 356 Lab Split, Brown Cork 5th Floor Front Wing Mechanical Room
150LF G NAD*
M-84 MH-5-357, 358, 359 9x9 Black Floor Tile 5th Floor Office 150SF G 1.8% Chrysotile
M-85 MH-3-363, 364, 365 Baseboard Adhesive, White 3rd Floor Front Wing 500LF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-86 MH-3-375, 376
12x12 Brown Floor Tile w/Tan Spots
3rd Floor East Wing 10000SF G NAD*
M-86A MH-3-375 Lab Split, Black Mastic 3rd Floor East Wing 10000SF G 1.5% Chrysotile
M-86 MH-2-422
12x12 Brown Floor Tile w/Tan Spots
N2-85, Half, rest Beige, C2-112 500SF G NAD*
M-86A MH-2-422 Lab Split, Tan/Black Mastic N2-85, Half, rest Beige, C2-112 500SF G 1.8% Chrysotile
M-86 MH-1-441
12x12 Brown Floor Tile w/Tan Spots
1st Floor Stairwell Access Maintenance Closet
150SF G NAD**
M-86A MH-1-441 Lab Split, Black Mastic 1st Floor Stairwell Access Maintenance Closet
150SF G NAD**
M-87 MH-3-378, 379, 380 Baseboard Adhesive, Dark Brown Service Elevator Area 100LF G NAD
M-87A MH-3-378, 379, 380 Lab Split, Dark Brown Baseboard Service Elevator Area 100LF G NAD
M-88 MH-3-381, 382, 383 Linoleum, Pink C3-51, 50, 52, 53 1500SF G NAD
Comprehensive Asbestos Survey and Inventory VAMC - Wilkes-Barre Building #1
PARS Project No. 1040-01
HA
Number
Sample Number(s) Material Type / Description Sample Location(s) SF / LF Condition Analytical Result
M-88A MH-3-382, 383 Lab Split, Light Tan Mastic C3-51, 50, 52, 53 1500SF G NAD
M-89 MH-3-389, 390, 391 Linoleum, Maroon C3-32, 33, 27, 54, 26, 56 500SF G NAD
M-90 MH-2-392, 393, 394 12x12 Gray Floor Tile 2nd Floor Front Wing 5000SF G NAD
M-90A MH-2-392, 394 Lab Split, Light Gray Mastic 2nd Floor Front Wing 5000SF G NAD
M-90B MH-2-392, 393, 394 Lab Split, Yellow Mastic 2nd Floor Front Wing 5000SF G NAD
M-90C MH-2-392, 393, 394
Lab Split, Gray Leveling Compound
2nd Floor Front Wing N/A N/A NAD
M-91 MH-2-403, 404, 405 Baseboard Adhesive, Orange 2nd Floor Front Wing 250LF G NAD
M-92 MH-2-406, 407, 408 12x12 Teal Floor Tile 2nd Floor Front Wing, A2-59 2500SF G NAD
M-93 MH-2-412, 413, 414
12x12 White Floor Tile…