36C24419Q1040-017.pdf

PDF 691 KB Posted

Attached to
Fire Stop Barrier Inspection Services Lebanon VAMC
Solicitation number
36C24419Q1040
Issued by

About this file

This combined synopsis/solicitation from the Department of Veterans Affairs seeks firestop barrier inspection services at the Veterans Affairs Medical Center in Lebanon, Pennsylvania. The solicitation number is 36C24419Q1040, with an original response date of August 28, 2019. The NAICS code is 238310 and the procurement is set aside as a total SDVOSB. The statement of work in Attachment 1 provides additional details on the required services. Offerors must follow the quote submission instructions in Attachment 3 and provide pricing using the line item in Attachment 4. The service contract act wage determination number 2015-4231 applies. This is a new requirement not replacing any existing contract.

36C24419Q1040 B34 _ B35.pdf

View the file

Other files

File Type Posted
-18051.docx DOCX document
36C24419Q1040-0002002.rtf RTF text file
36C24419Q1040-0002001.docx DOCX document
36C24419Q1040-0002000.docx DOCX document
36C24419Q1040-0001000.docx DOCX document
36C24419Q1040-0001001.pdf PDF
36C24419Q1040-007.pdf PDF
36C24419Q1040-021.pdf PDF
36C24419Q1040-014.pdf PDF
36C24419Q1040-020.pdf PDF
36C24419Q1040-006.pdf PDF
36C24419Q1040-002.pdf PDF
36C24419Q1040-013.pdf PDF
36C24419Q1040-004.xlsx XLSX spreadsheet
36C24419Q1040-009.pdf PDF
36C24419Q1040-010.pdf PDF
36C24419Q1040-018.pdf PDF
36C24419Q1040-017.pdf PDF
36C24419Q1040-019.pdf PDF
36C24419Q1040-003.docx DOCX document
36C24419Q1040-011.pdf PDF
36C24419Q1040-012.pdf PDF
36C24419Q1040-000.docx DOCX document
36C24419Q1040-015.pdf PDF
36C24419Q1040-001.rtf RTF text file
36C24419Q1040-008.pdf PDF
36C24419Q1040-016.pdf PDF
36C24419Q1040-005.docx DOCX document
36C24419Q1040-019.pdf PDF
36C24419Q1040-008.pdf PDF
36C24419Q1040-002.pdf PDF
36C24419Q1040-000.docx DOCX document
36C24419Q1040-009.pdf PDF
36C24419Q1040-003.docx DOCX document
36C24419Q1040-001.rtf RTF text file
36C24419Q1040-016.pdf PDF
36C24419Q1040-005.docx DOCX document
36C24419Q1040-013.pdf PDF
36C24419Q1040-007.pdf PDF
36C24419Q1040-020.pdf PDF
36C24419Q1040-012.pdf PDF
36C24419Q1040-021.pdf PDF
36C24419Q1040-014.pdf PDF
36C24419Q1040-010.pdf PDF
36C24419Q1040-004.xlsx XLSX spreadsheet
36C24419Q1040-015.pdf PDF
36C24419Q1040-018.pdf PDF
36C24419Q1040-011.pdf PDF
36C24419Q1040-006.pdf PDF
Show all 49

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP UP

DN DN

85 SF

Bedroom S106C

86 SF

Bedroom S106B

88 SF

Double S106

54 SF

Toilet S106A

86 SF

Bedroom S104C

85 SF

Bedroom S104B

88 SF

Double S104

54 SF

Toilet S104A

180 SF

Single S102

68 SF

ADA Toilet S102A

180 SF

Single S100

68 SF

ADA Toilet S100A

124 SF

Vestibule S001

49 SF

HAC /

Storage

S005

111 SF

Office/Meeting S004

65 SF

Storage S003

315 SF

SARRTP

Desk S002

86 SF

Bedroom S110C

85 SF

Bedroom S110B

88 SF

Double S110

54 SF

Toilet S110A

85 SF

Bedroom S114B

86 SF

Bedroom S114C

88 SF

Double S114

54 SF

Toilet S114A

86 SF

Bedroom S116C

85 SF

Bedroom S116B

88 SF

Double S116

54 SF

Toilet S116A

192 SF

Single S118

54 SF

Toilet S118A

612 SF

Corridor S007

85 SF

Bedroom S115B

86 SF

Bedroom S115C

88 SF

Double S115

54 SF

Toilet S115A

86 SF

Bedroom S113B

85 SF

Bedroom S113C

88 SF

Double S113

54 SF

Toilet S113A

181 SF

Single

S111 69 SF

ADA Toilet S111A

114 SF

Mechanical S009

78 SF

Laundry S008

85 SF

Bedroom S105C

86 SF

Bedroom S105B

88 SF

Double S105

54 SF

Toilet S105A

86 SF

Bedroom S107C

85 SF

Bedroom S107B

88 SF

Double

S107 54 SF

Toilet S107A

191 SF

Single S109

53 SF

Toilet S109A

685 SF

Corridor S006

55 SF

Toilet S112A

159 SF

Single S112

32 SF

Elec. Clos.

S007A

63 SF

Elec. Clos.

S008B

141 SF

Single S103

140 SF

Single S101

53 SF

Toilet S103A

53 SF

Toilet S101A

18 SF

Stor.

S008A

18 SF

Stor.

S008C

93 SF

Corridor S029

Group/Living Room

S030

Group Room S132

Toilet S131

E X

IS

T

D

IS

T A

N C

E

4'

-3

EXIST DISTANCE = 90'-0"EXIST DISTANCE = 56'-2"

TEC

TEC

TEC

T E

C

TEC

FEC

FEC

F E

C

68 SF

Vestibule C019

83 SF

Vestibule C001

1119 SF

Dining Social Space

C018

196 SF

Kitchen/Dish C022

332 SF

Gameroom / Lounge

C014

233 SF

Private Family Room

C028

175 SF

Vestibule C005

41 SF

Storage C020

42 SF

Toilet C026

91 SF

Office/Reception C010

233 SF

Private Family Room

C012

446 SF

Mechanical C013

109 SF

Rec.

Therapy Office

C016

45 SF

Toilet C027

320 SF

Gallery/Reception

C002 175 SF

Vestibule C006

110 SF

Rec.

Therapy Office

C01559 SF

Electric C025

178 SF

Servery C021

71 SF

Walk-In Refrigerator

C023 36 SF

HAC

C024

320 SF

Gallery/Reception C002

157 SF

Computer Room

C011

44 SF

Elev Eqmt C017

58 SF

Elevator

CE010

227 SF

Corridor

C003187 SF

Corridor C004

EXIST DISTANCE = 50'-3"

EXIST DISTANCE = 49'-2"

TEC

TEC

T E

C

T E

C

T E

C

T E

C

FEC

F E

C

FEC

PA Office & Consult.

C030

Waiting C031

F E

F E

CS137

C101 C102 C103 C105

C106 C107 C109

CS138

C122 C123

C118 C117

C121

C120

C133 C132 C124A C130 C129 C128

C127C126C125

C124

C111

C112

C115C116 C113C114

C110C100

C108C104

S008

90 SF

Counselor C102

90 SF

Counselor C103

90 SF

Counselor C104

161 SF

Staff Lounge C105

90 SF

Counselor C106

90 SF

Counselor C107

90 SF

Office C108

155 SF

Office C110

155 SF

Office C100

73 SF

Work Room C119

38 SF

IT

C120

59 SF

Electric C121

42 SF

Men's C122

119 SF

Counselor C133

92 SF

Lockers C132

213 SF

Large Conference

C124

99 SF

Counselor C130

99 SF

Psych C129

99 SF

Psych C128

80 SF

Copy/Storage C125

117 SF

Small Conference

C126

99 SF

Counselor C127

132 SF

Business Office

C118

131 SF

RN Office C117

148 SF

Social Worker

C116

124 SF

Social Worker

C115

119 SF

Social Worker

C114

131 SF

Social Worker

C113

34 SF

HAC

C112

78 SF

Office C111

631 SF

Corridor C140

58 SF

Elevator

CE100

45 SF

Women's C123

90 SF

Assistant's Office

C101

90 SF

Assistant's Office

C109

147 SF

Stair 1

CS137

147 SF

Stair 2

CS138

148 SF

Waiting Area C143

183 SF

Corridor C141

325 SF

Corridor C142

87 SF

Corridor C144

EXIST DISTANCE = 56'-3"

EXIST DISTANCE = 99'-1"

T E

C

F E

C

T E

C

F E

C

F E

C

Life Safety Plan Legend

FE

FACP

SD

F

F

Standard Bracket-Mounted Fire Extinguisher

Fire Alarm Control Panel

Smoke Detector

Pull Station

Strobe

Emergency Lighting

Path of Egress

New Exit Sign

Width Provided

Egress Capacity

36"

Smoke Rated Partition

1 HR Partition

2 HR Partition

FEC

Fire Extinguisher Cabinet

TEC Tactile Exit Sign

NOTE: SEE MEP DRAWINGS FOR

COMPLETE ELECTRICAL AND FIRE

PROTECTION INFORMATION

NEW FIRE EXTINGUISHERS TO BE

FURNISHED AND INSTALLED BY G.C.

PROJECT

NORTH

KEY PLAN

TRUE

NORTH

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. of

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of

Facilities

Management o n e e ig h th i n c h o n e f o o t

B

A

C

D

E

F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t 4 o n e q u a rt e r in c h o n e f o o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

MEP & Civil Engineers Buchart Horn 445 W Philadelphia St York, PA 17401 717.852.1400

Fire Protection Engineers

GTA

94 Boston Hill Plymouth, PA 18651-3225 570.779.7843

Structural Engineers QproQ Engineering, Inc.

187 N. Main ST Wilkes-Barre PA 18792 570.823.9935

THESE RECORD DOCUMENTS HAVE BEEN PREPARED BASED ON

INFORMATION PROVIDED BY OTHERS. THE DESIGN PROFESSIONAL HAS

NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THIS

INFORMATION AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR

OMISSIONS WHICH MAY BE INCORPORATED HEREIN AS A RESULT.

Expand Behavioral Health

Clinic Services

7/15/2011

A0-100

595-901

AuthorChecker

Space Summary &

Lifesafety Plan - SARRTP &

Central Building

1/8" = 1'-0"1 Area Plan - SARRTP

1/8" = 1'-0"2 Area Plan - Central Building 1st Floor

1/8" = 1'-0"3 Area Plan - Central Building 2nd Floor

ROOM AREA SCHEDULE - SARRTP

Number Name Area

S106C Bedroom 85 SF

S107 Double 88 SF

S107A Toilet 54 SF

S107B Bedroom 85 SF

S107C Bedroom 86 SF

S109 Single 191 SF

S109A Toilet 53 SF

S110 Double 88 SF

S110A Toilet 54 SF

S110B Bedroom 85 SF

S110C Bedroom 86 SF

S111 Single 181 SF

S111A ADA Toilet 69 SF

S112 Single 159 SF

S112A Toilet 55 SF

S113 Double 88 SF

S113A Toilet 54 SF

S113B Bedroom 86 SF

S113C Bedroom 85 SF

S114 Double 88 SF

S114A Toilet 54 SF

S114B Bedroom 85 SF

S114C Bedroom 86 SF

S115 Double 88 SF

S115A Toilet 54 SF

S115B Bedroom 85 SF

S115C Bedroom 86 SF

S116 Double 88 SF

S116A Toilet 54 SF

S116B Bedroom 85 SF

S116C Bedroom 86 SF

S118 Single 192 SF

S118A Toilet 54 SF

S131 Toilet 85 SF

S132 Group Room 198 SF

7873 SF

ROOM AREA SCHEDULE - SARRTP

Number Name Area

SARRTP

T.O. First Floor

S001 Vestibule 124 SF

S002 SARRTP Desk 315 SF

S003 Storage 65 SF

S004 Office/Meeting 111 SF

S005 HAC / Storage 49 SF

S006 Corridor 685 SF

S007 Corridor 612 SF

S007A Elec. Clos. 32 SF

S008 Laundry 78 SF

S008A Stor. 18 SF

S008B Elec. Clos. 63 SF

S008C Stor. 18 SF

S009 Mechanical 114 SF

S029 Corridor 93 SF

S030 Group/Living Room 558 SF

S100 Single 180 SF

S100A ADA Toilet 68 SF

S101 Single 140 SF

S101A Toilet 53 SF

S102 Single 180 SF

S102A ADA Toilet 68 SF

S103 Single 141 SF

S103A Toilet 53 SF

S104 Double 88 SF

S104A Toilet 54 SF

S104B Bedroom 85 SF

S104C Bedroom 86 SF

S105 Double 88 SF

S105A Toilet 54 SF

S105B Bedroom 86 SF

S105C Bedroom 85 SF

S106 Double 88 SF

S106A Toilet 54 SF

S106B Bedroom 86 SF

ROOM AREA SCHEDULE - Central Building

Number Name Area

Pipe Trench

C32 Room 503 SF

C33 Pipe Trench 0 SF

C34 Pipe Trench 502 SF

C35 Elevator Pit 58 SF

1063 SF

T.O. First Floor

C001 Vestibule 83 SF

C002 Gallery/Reception 320 SF

C003 Corridor 227 SF

C004 Corridor 187 SF

C005 Vestibule 175 SF

C006 Vestibule 175 SF

C010 Office/Reception 91 SF

C011 Computer Room 157 SF

C012 Private Family Room 233 SF

C013 Mechanical 446 SF

C014 Gameroom / Lounge 332 SF

C015 Rec. Therapy Office 110 SF

C016 Rec. Therapy Office 109 SF

C017 Elev Eqmt 44 SF

C018 Dining Social Space 1119 SF

C019 Vestibule 68 SF

C020 Storage 41 SF

C021 Servery 178 SF

C022 Kitchen/Dish 196 SF

C023 Walk-In Refrigerator 71 SF

C024 HAC 36 SF

C025 Electric 59 SF

C026 Toilet 42 SF

C027 Toilet 45 SF

C028 Private Family Room 233 SF

C029 Corridor 127 SF

C030 PA Office & Consult. 152 SF

C031 Waiting 39 SF

CE010 Elevator 58 SF

5152 SF

T. O. Second Floor

C100 Office 155 SF

C101 Assistant's Office 90 SF

C102 Counselor 90 SF

C103 Counselor 90 SF

C104 Counselor 90 SF

C105 Staff Lounge 161 SF

C106 Counselor 90 SF

C107 Counselor 90 SF

C108 Office 90 SF

C109 Assistant's Office 90 SF

C110 Office 155 SF

C111 Office 78 SF

C112 HAC 34 SF

C113 Social Worker 131 SF

C114 Social Worker 119 SF

C115 Social Worker 124 SF

C116 Social Worker 148 SF

C117 RN Office 131 SF

C118 Business Office 132 SF

C119 Work Room 73 SF

C120 IT 38 SF

C121 Electric 59 SF

C122 Men's 42 SF

C123 Women's 45 SF

C124 Large Conference 213 SF

C125 Copy/Storage 80 SF

C126 Small Conference 117 SF

C127 Counselor 99 SF

C128 Psych 99 SF

C129 Psych 99 SF

C130 Counselor 99 SF

C132 Lockers 92 SF

C133 Counselor 119 SF

C140 Corridor 631 SF

C141 Corridor 183 SF

C142 Corridor 325 SF

C143 Waiting Area 148 SF

C144 Corridor 87 SF

CE100 Elevator 58 SF

CS137 Stair 1 147 SF

CS138 Stair 2 147 SF

5086 SF

PROGRAM NET SF

CENTRAL BUILDING (1st Floor) 5151 sf CENTRAL BUILDING (2nd Floor) 5947 sf SARRTP 8262 sf

Total 19360 sf

PRTTP (Temporary Alternate) 6105 sf

Revision Schedule

Number Description Date

34 & 35AS BUILT

Sheets
A0-000 - Abbreviations, Symbols and Notes
A0-001 - Partition Types and Schedules
A0-100 - Space Summary & Lifesafety Plan - SARRTP & Central Building
A0-101 - Space Summary & Lifesaftey Plan - PRRTP
A1-100 - Facility Plans - SARRTP
A1-100a - Corridor and Utility Layout Plan - SARRTP
A1-101 - Facility Plans - Central Building
A1-101a - Corridor and Utility Layout Plan - Central Building
A1-102 - Facility Plans - PRRTP
A1-102a - Corridor and Utility Layout Plan - PRRTP
A1-103 - Walkway and Springhouse Plans, Elevations and Sections
A1-110 - Attic Plan - SARRTP & Central Buildings
A1-112 - Attic Plan - PRRTP
A1-200 - Roof Plan - SARRTP & PRRTP
A1-201 - Roof Plan - Central Building
A2-100 - Enlarged Resident Unit Plans
A3-100 - Building Elevations - SARRTP
A3-101 - Building Elevations - Central Building
A3-102 - Building Elevations - PRRTP
A4-100 - Building Sections - Central Building
A4-200 - Building Sections - SARRTP Wing
A5-100 - Wall Sections and Details
A5-101 - Wall Sections and Details
A5-102 - Wall Sections and Details
A5-103 - Pipe Trench Plans and Details
A5-200 - Pavillion Details
A6-100 - Stair / Elevator Plans, Sections, Details
A7-100 - Enlarged Plans and Interior Elevations
A7-101 - Enlarged Plans and Interior Elevations
A7-201 - Casework Details
A8-100 - Door Schedule, Elevations and Details
A8-101 - Window Schedule, Elevations and Details
A9-100 - Reflected Ceiling Plans - SARRTP
A9-101 - Reflected Ceiling Plans - Central Building
A9-102 - Reflected Ceiling Plans - PRRTP
A9-200 - Room Finish Schedule and Details
G0-000 - Cover Sheet
G0-001 - Drawing List