FedBizOpps Amendment to a Previous Combined Solicitation

CLASSIFICATION CODE

SUBJECT

CONTRACTING OFFICE'S

ZIP-CODE

SOLICITATION NUMBER

BASE NOTICE TYPE

RESPONSE DATE (MM-DD-YYYY)

ARCHIVE

DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS

SET-ASIDE

NAICS CODE

CONTRACTING OFFICE

ADDRESS

POINT OF CONTACT

(POC Information Automatically Filled from User Profile Unless Entered)

DESCRIPTION

See Attachment

AGENCY'S URL

URL DESCRIPTION

AGENCY CONTACT'S EMAIL

ADDRESS

EMAIL DESCRIPTION

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

GENERAL INFORMATION

PLACE OF PERFORMANCE

* = Required Field FedBizOpps Amendment to a Previous Combined Solicitation Rev. March 2010 Access Control System (ACS): Card Readers and Control Panels Spare parts only 19805 36C24419Q0492 04-11-2019 N 334118 Department of Veterans Affairs Network Contracting Office 4 debra.willard@va.gov Department of Veterans Affairs Network Contracting Office 4 PVAMC Philadelphia VA Medical Center 3900 Woodlawn Ave Philadelphia, PA 19104

QUESTIONS ASKED:

In regards to the Door Controllers, Are they POE controllers or non POE controllers?

Are the back boxes required, single gang or double gang electrical boxes?

Are they running IDentipass or PremiSYS?

Note #7 sounds as if they still have IDentipass but it mentions PremiSYS.

If they are running IDentipass, those series 9000 boards are no longer available and not under warranty.

We have a conversion via a Mercury controller but is highly recommended to upgrade to PremiSYS.

If they are running PremiSYS, do they need a combination of 1501 and mr52?

ANSWERS TO QUESTIONS BELOW:

Quantity (55) > The readers are Schlage, multi-technology single-gang reader, black, CSN format: Mfrs. Reference

Quantity (55) > Back Box – Single Gange Back Box

(9) > The controllers are PremiSys LP-Two Reader Controllers

(9) > The controllers are PremiSys Large enclosure which include 8 positions. One position can be used to mount either a 3.6amp or 10 amp power supply. Measures 17.75: (45.1 cm) x 18.13” (46.1 cm)

(9) > Controllers PremiSys Enclosure Lock & Key Set.

(9) > 10 Amp Power Supply with PremiSys Mounting Bracket. Non-ETL

(27) PremiSys Two-Reader Boards Series 3. Mfrs reference # MR52-53

End of Document