FedBizOpps Amendment to a Previous Combined Solicitation
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
BASE NOTICE TYPE
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field FedBizOpps Amendment to a Previous Combined Solicitation Rev. March 2010 Access Control System (ACS): Card Readers and Control Panels Spare parts only 19805 36C24419Q0492 04-11-2019 N 334118 Department of Veterans Affairs Network Contracting Office 4 debra.willard@va.gov Department of Veterans Affairs Network Contracting Office 4 PVAMC Philadelphia VA Medical Center 3900 Woodlawn Ave Philadelphia, PA 19104
QUESTIONS ASKED:
In regards to the Door Controllers, Are they POE controllers or non POE controllers?
Are the back boxes required, single gang or double gang electrical boxes?
Are they running IDentipass or PremiSYS?
Note #7 sounds as if they still have IDentipass but it mentions PremiSYS.
If they are running IDentipass, those series 9000 boards are no longer available and not under warranty.
We have a conversion via a Mercury controller but is highly recommended to upgrade to PremiSYS.
If they are running PremiSYS, do they need a combination of 1501 and mr52?
ANSWERS TO QUESTIONS BELOW:
Quantity (55) > The readers are Schlage, multi-technology single-gang reader, black, CSN format: Mfrs. Reference
Quantity (55) > Back Box – Single Gange Back Box
(9) > The controllers are PremiSys LP-Two Reader Controllers
(9) > The controllers are PremiSys Large enclosure which include 8 positions. One position can be used to mount either a 3.6amp or 10 amp power supply. Measures 17.75: (45.1 cm) x 18.13” (46.1 cm)
(9) > Controllers PremiSys Enclosure Lock & Key Set.
(9) > 10 Amp Power Supply with PremiSys Mounting Bracket. Non-ETL
(27) PremiSys Two-Reader Boards Series 3. Mfrs reference # MR52-53
End of Document