36C24419B0007-0003002.pdf

PDF 24 KB Posted

Attached to
Renovate Building 1, Ground Floor East & 3rd Floor Project No. 542-15-204
Solicitation number
36C24419B0007
Issued by

About this file

36C24419B0007 0003 062000.pdf

View the file

Other files

File Type Posted
36C24419B0007-0005011.pdf PDF
36C24419B0007-0005007.pdf PDF
36C24419B0007-0005002.pdf PDF
36C24419B0007-0005010.pdf PDF
36C24419B0007-0005000.docx DOCX document
36C24419B0007-0005008.pdf PDF
36C24419B0007-0005003.pdf PDF
36C24419B0007-0005009.pdf PDF
36C24419B0007-0005006.pdf PDF
36C24419B0007-0005005.pdf PDF
36C24419B0007-0005004.pdf PDF
36C24419B0007-0005001.pdf PDF
36C24419B0007-0004000.docx DOCX document
36C24419B0007-0003012.pdf PDF
36C24419B0007-0003000.docx DOCX document
36C24419B0007-0003008.pdf PDF
36C24419B0007-0003015.pdf PDF
36C24419B0007-0003009.pdf PDF
36C24419B0007-0003005.pdf PDF
36C24419B0007-0003016.pdf PDF
36C24419B0007-0003013.pdf PDF
36C24419B0007-0003010.pdf PDF
36C24419B0007-0003003.pdf PDF
36C24419B0007-0003004.pdf PDF
36C24419B0007-0003011.pdf PDF
36C24419B0007-0003006.pdf PDF
36C24419B0007-0003007.pdf PDF
36C24419B0007-0003001.pdf PDF
36C24419B0007-0003017.pdf PDF
36C24419B0007-0003014.pdf PDF
36C24419B0007-0002000.docx DOCX document
36C24419B0007-0002002.pdf PDF
36C24419B0007-0002001.pdf PDF
36C24419B0007-0001000.docx DOCX document
Final_Drawings_01072019.pdf PDF
Final_Specification_01072019.pdf PDF
GOVERNMENT_FURNISHED_PROPERTY.pdf PDF
36C24419B0007.docx DOCX document
36C24419B0007_1.docx DOCX document
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RENOVATE BUILDING 1, GROUND FLOOR EAST & 3RD FLOOR 02-19

VA MEDICAL CENTER, COATESVILLE, PA

Project# 542-15-204

542-15-204 06 20 00 - 1

SECTION 06 20 00

FINISH CARPENTRY

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Interior millwork.

B. Items specified:

1. Counter Shelf.

2. Counter or Work Tops.

1.2 RELATED REQUIREMENTS

A. Adhesive, Paint, and Finish VOC Limits: Section 01 81 13, SUSTAINABLE

CONSTRUCTION REQUIREMENTS.

B. Woodwork Finish and Color: Section 09 06 00, SCHEDULE FOR FINISHES.

C. Fabricated Metal brackets, bench supports and countertop legs: Section

05 50 00, METAL FABRICATIONS.

D. Framing, furring and blocking: Section 06 10 00, ROUGH CARPENTRY.

E. Wood doors: Section 08 14 00, WOOD DOORS.

F. Electrical light fixtures and duplex outlets: Division 26, ELECTRICAL.

1.3 APPLICABLE PUBLICATIONS

A. Comply with references to extent specified in this section.

B. ASTM International:

1. A36/A36M-14 - Carbon Structural Steel.

2. A53/A53M-12 - Pipe, Steel, Black and Hot-Dipped Zinc Coated, Welded and Seamless.

3. A240/A240M-15b - Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications.

4. B26/B26M-14e1 - Aluminum-Alloy Sand Castings.

5. B221-14 - Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes.

6. E84-15b - Surface Burning Characteristics of Building Materials.

C. American Hardboard Association (AHA):

1. A135.4-04 - Basic Hardboard.

D. Architectural Woodwork Institute (AWI):

Project# 542-15-204

542-15-204 06 20 00 - 2

1. AWI-09 - Architectural Woodwork Quality Standards and Quality

Certification Program.

E. Builders Hardware Manufacturers Association (BHMA):

1. A156.9-10 - Cabinet Hardware.

2. A156.11-14 - Cabinet Locks.

3. A156.16-13 - Auxiliary Hardware.

F. Federal Specifications (Fed. Spec.):

1. A-A-1922A - Shield Expansion (Calking Anchors, Single Lead).

2. A-A-1936A - Adhesive, Contact, Neoprene Rubber.

3. FF-N-836E- Nut: Square, Hexagon, Cap, Slotted, Castle, Knurled, Welding.

4. FF-S-111D(1) - Screw, Wood (Notice 1 inactive for new design).

5. MM-L-736C(1) - Lumber, Hardwood.

G. Hardwood Plywood and Veneer Association (HPVA):

1. HP1-09 - Hardwood and Decorative Plywood.

H. Military Specification (Mil. Spec):

1. MIL-L-19140E - Lumber and Plywood, Fire-Retardant Treated.

I. National Particleboard Association (NPA):

1. A208.1-09 - Wood Particleboard.

J. National Electrical Manufacturers Association (NEMA):

1. LD 3-05 - High-Pressure Decorative Laminates.

K. U.S. Department of Commerce, Product Standard (PS):

1. PS1-07 - Construction and Industrial Plywood.

2. PS20-10 - American Softwood Lumber Standard.

1.4 PREINSTALLATION MEETINGS

A. Conduct preinstallation meeting at project site minimum 30 days before beginning Work of this section.

1. Required Participants:

a. Contracting Officer's Representative.

b. VA Interior Designer.

c. Contractor.

d. Installer.

2. Meeting Agenda: Distribute agenda to participants minimum 3 days before meeting.

a. Installation schedule.

Project# 542-15-204

542-15-204 06 20 00 - 3

b. Installation sequence.

c. Preparatory work.

d. Protection before, during, and after installation.

e. Installation.

f. Terminations.

g. Transitions and connections to other work.

h. Other items affecting successful completion.

3. Document and distribute meeting minutes to participants to record decisions affecting installation.

1.5 SUBMITTALS

A. Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

B. Submittal Drawings:

1. Show size, configuration, and fabrication and installation details.

2. Millwork items - Half full size scale for sections and details 1: 50

(1/4 inch) for elevations and plans.

C. Manufacturer's Literature and Data:

1. Description of each product.

a. Finish hardware.

b. Sinks with fittings.

c. Electrical components.

2. List of acceptable sealers for fire retardant materials.

3. Installation instructions.

D. Samples:

1. Plastic Laminate Finished Plywood and Particleboard: 150 mm by

300 mm (6 by 12 inches) square, each type and color .

a. Submit quantity required to show full color and texture range.

2. Approved samples may be incorporated into work.

E. Sustainable Construction Submittals:

1. Recycled Content: Identify post-consumer and pre-consumer recycled content percentage by weight.

2. Low Pollutant-Emitting Materials:

a. Show volatile organic compound types and quantities.

b. Certify each composite wood and agrifiber product contains no added urea formaldehyde.

Project# 542-15-204

542-15-204 06 20 00 - 4

F. Certificates: Certify each product complies with specifications.

1. Fire retardant treatment of materials.

2. Moisture content of materials.

G. Qualifications: Substantiate qualifications comply with specifications.

1. Fabricator with project experience list .

2. Installer with project experience list .

1.6 QUALITY ASSURANCE

A. Fabricator Qualifications:

1. Regularly fabricates specified products.

2. Fabricated specified products with satisfactory service on five similar installations for minimum five years.

a. Project Experience List: Provide contact names and addresses for completed projects.

B. Installer Qualifications:

1. Regularly installs specified products.

2. Installed specified products with satisfactory service on five similar installations for minimum five years.

a. Project Experience List: Provide contact names and addresses for completed projects.

1.7 DELIVERY, STORAGE AND HANDLING

A. Deliver products in manufacturer's original sealed packaging.

B. Mark packaging, legibly. Indicate manufacturer's name or brand, type, color, production run number, and manufacture date.

C. Before installation, return or dispose of products within distorted, damaged, or opened packaging.

D. Store products indoors in dry, weathertight facility.

E. Protect products from damage during handling and construction operations.

1.8 FIELD CONDITIONS

A. Environment:

1. Product Temperature: Minimum 21 degrees C (70 degrees F) for minimum

48 hours before installation.

2. Work Area Ambient Conditions: HVAC systems are complete, operational, and maintaining facility design operating conditions

Project# 542-15-204

542-15-204 06 20 00 - 5 continuously, beginning 48 hours before installation until

Government occupancy.

3. Install products when building is permanently enclosed and when wet construction is completed, dried, and cured.

4. Do not install finish lumber or millwork in any room or space where wet process systems such as concrete, masonry, or plaster work is not complete and dry.

B. Field Measurements: Verify field conditions affecting fabrication and installation. Show field measurements on Submittal Drawings.

1. Coordinate field measurement and fabrication schedule to avoid delay.

1.9 WARRANTY

A. Construction Warranty: FAR clause 52.246-21, "Warranty of

Construction."

PART 2 - PRODUCTS

2.1 SYSTEM PERFORMANCE

A. Design acoustical panel complying with specified performance:

1. Surface Burning Characteristics: When tested according to ASTM E84.

a. Flame Spread Rating: 25 maximum.

b. Smoke Developed Rating: 450 maximum.

2.2 MATERIALS

A. Grading and Marking: Factory mark with grade stamp lumber and plywood of inspection agency approved by the Board of Review, American Lumber

Standard Committee.

B. Lumber:

1. Sizes:

a. Lumber Size references, unless otherwise specified, are nominal sizes, and actual sizes within manufacturing tolerances allowed by the standard under which product is produced.

b. Millwork, standing and running trim, and rails: Actual size as shown or specified.

2. Hardwood: MM-L-736, species as specified for each item.

3. Softwood: PS-20, exposed to view appearance grades:

Project# 542-15-204

542-15-204 06 20 00 - 6

a. Use C select or D select, vertical grain for transparent finish including stain transparent finish.

b. Use Prime for painted or opaque finish.

4. Use edge grain Wood members exposed to weather.

5. Moisture Content:

a. 32 mm (1-1/4 inches) or less nominal thickness: 12 percent on 85 percent of the pieces and 15 percent on the remainder.

b. Other materials: According to standards under which the products are produced.

6. Fire Retardant Treatment: Mil. Spec. MIL-L-19140E.

a. Treatment and performance inspection by an independent and qualified testing agency that establishes performance ratings.

b. Each piece of treated material bear identification of the testing agency and indicate performance according to such rating of flame spread and smoke developed.

c. Treat wood for maximum flame spread of 25 and smoke developed of

25.

d. Fire Resistant Softwood Plywood:

1) Grade A, Exterior, plywood for treatment.

2) Surface Burning Characteristics: When tested according to

ASTM E84.

a) Flame spread: 0 to 25.

b) Smoke developed: 100 maximum.

e. Fire Resistant Hardwood Plywood:

1) Core: Fire retardant treated softwood plywood.

2) Hardwood face and back veneers untreated.

3) Factory seal panel edges.

C. Plywood:

1. Softwood Plywood: DOC PS1.

a. Plywood, 13 mm (1/2 inch) and thicker; minimum five ply construction, except 32 mm (1-1/4 inch) thick plywood minimum seven ply.

b. Plastic Laminate Plywood Cores:

1) Exterior Type, and species group.

2) Veneer Grade: A-C.

Project# 542-15-204

542-15-204 06 20 00 - 7

c. Shelving Plywood:

1) Interior Type, any species group.

2) Veneer Grade: A-B or B-C.

d. Other: As specified for item.

2. Hardwood Plywood: HPVA: HP.1.

a. Species of Face Veneer: As shown or as specified with each particular item.

b. Grade:

1) Transparent Finish: Type II (interior) A grade veneer.

2) Paint Finish: Type II (interior) Sound Grade veneer.

c. Species and Cut: Plain sliced red oak unless specified otherwise.

D. Particleboard: NPA A208.1, Type 1, Grade 1-M-3.

1. Plastic Laminate Particleboard Cores:

a. Type 1, Grade 1-M-3, unless otherwise specified.

b. Type 2, Grade 2-M-2, exterior bond, for tops with sinks.

E. Building Board (Hardboard):

1. ANSI/AHA A135.4, 6 mm (1/4 inch) thick unless specified otherwise.

2. Perforated hardboard (Pegboard): Type 1, Tempered perforated 6 mm

(1/4 inch) diameter holes, on 25 mm (1 inch) centers each way, smooth surface one side.

F. Plastic Laminate: NEMA LD-3.

1. Exposed Laminate Surfaces including Countertops, and Sides of

Cabinet Doors: Grade HGL.

2. Cabinet Interiors including Shelving: NEMA, CLS as a minimum, with the following:

a. Plastic laminate clad plywood or particle board.

b. Resin impregnated decorative paper thermally fused to particle board.

3. Plastic Laminate Covered Wood Tops Backing: Grade HGP.

4. Postformed Surfaces: Grade HGP.

G. Stainless Steel: ASTM A240, Type 302 or 304.

H. Cast Aluminum: ASTM B26.

I. Extruded Aluminum: ASTM B221.

Project# 542-15-204

542-15-204 06 20 00 - 8

2.3 PRODUCTS - GENERAL

A. Basis of Design: Section 09 06 00, SCHEDULE FOR FINISHES.

B. Provide each product from one manufacturer and from one production run.

2.4 FABRICATION

A. General:

1. AWI Custom Grade for interior millwork.

2. Finish woodwork, free from pitch pockets.

3. Trim, standard stock molding and members of same species, except where special profiles are shown.

4. Plywood, minimum 13 mm (1/2 inch), unless otherwise shown on

Drawings or specified.

5. Edges of members in contact with concrete or masonry having a square corner caulking rebate.

6. Fabricate members less than 4 m (14 feet) in length from one piece of lumber, back channeled and molded a shown.

7. Fabricate interior trim and items of millwork to be painted from jointed, built-up, or laminated members, unless otherwise shown on

Drawings or specified.

8. Plastic Laminate Work:

a. Factory glued to either a plywood or a particle board core, thickness as shown on Drawings or specified.

b. Cover exposed edges with plastic laminate, except where aluminum, stainless steel, or plastic molded edge strips are shown on drawings or specified. Use plastic molded edge strips on 19 mm (3/4 inch) thick or thinner core material.

c. Provide plastic backing sheet on underside of countertops, vanity tops, thru-wall counter and sills including back splashes and end splashes of countertops.

d. Use backing sheet on concealed large panel surface when decorative face does not occur.

B. Plastic Laminate Counter or Work Tops:

1. Thickness: 32 mm (1-1/4 inch) thick core unless shown otherwise.

a. Edges:

1) Decorative laminate for exposed edges of tops, back, and endsplash, 38 mm (1-1/2 inches) wide.

Project# 542-15-204

542-15-204 06 20 00 - 9

2) Plastic or metal edges for top edges less than 38 mm

(1-1/2 inches) wide.

b. Assemble backsplash and end splash to counter top.

c. Use one piece counters for straight runs.

d. Miter corners for field joints with overlapping blocking on underside of joint.

2.5 ACCESSORIES

A. Hardware:

1. Rough Hardware:

a. Provide rough hardware with a standard plating, applied after punching, forming and assembly of parts; galvanized, cadmium plated, or zinc-coated by electric-galvanizing process.

Galvanized where specified.

b. Fasteners:

1) Bolts with Nuts: FF-N-836.

2) Expansion Bolts: A-A-1922A.

3) Screws: Fed. Spec. FF-S-111.

2. Finish Hardware:

a. Cabinet Hardware: ANSI A156.9.

1) Door/Drawer Pulls: B02011. Door in seismic zones: B03182.

2) Drawer Slides: B05051 for drawers over 150 mm (6 inches) deep, B05052 for drawers 75 mm to 150 mm (3 to 6 inches) deep, and B05053 for drawers less than 75 mm (3 inches) deep.

3) Sliding Door Tracks: B07063.

4) Adjustable Shelf Standards: B4061 with shelf rest B04083.

5) Concealed Hinges: B1601, minimum 110 degree opening.

6) Butt Hinges: B01361, for flush doors, B01381 for inset lipped doors, and B01521 for overlay doors.

7) Cabinet Door Catch: B0371 or B03172.

8) Vertical Slotted Shelf Standard: B04103 with shelf brackets

B04113, sized for shelf depth.

b. Cabinet Locks: ANSI A156.11.

1) Drawers and Hinged Door: E07262.

2) Sliding Door: E07162.

c. Auxiliary Hardware: ANSI A156.16.

Project# 542-15-204

542-15-204 06 20 00 - 10

1) Shelf Bracket: B04041, japanned or enameled finish.

2) Combination Garment rod and Shelf Support: B04051 japanned or enamel finish.

3) Closet Bar: L03131 chrome finish of required length.

4) Handrail Brackets: L03081 or L03101.

a) Cast Aluminum, satin polished finish.

b) Cast Malleable Iron, japanned or enamel finish.

d. Steel Channel Frame and Leg supports for Counter top. Fabricated under Section 05 50 00, METAL FABRICATIONS.

e. Pipe Bench Supports:

1) Pipe: ASTM A53.

f. Thru-Wall Counter Brackets:

1) Steel angles drilled for fasteners on 100 mm (4 inches) centers.

2) Baked enamel prime coat finish.

B. Adhesive:

1. Plastic Laminate: Fed. Spec. A-A-1936.

2. Interior Millwork: Unextended urea resin, unextended melamine resin, phenol resin, or resorcinol resin.

PART 3 - EXECUTION

3.1 PREPARATION

A. Examine and verify substrate suitability for product installation.

B. Protect existing construction and completed work from damage.

C. Clean substrates. Remove contaminants capable of affecting subsequently installed product's performance.

3.2 INSTALLATION

A. Installation:

1. Prime millwork receiving transparent finish and back-paint concealed surfaces.

2. Fasten trim with fine finishing nails, screws, or glue as required.

3. Set nails for putty stopping. Provide washers under bolt heads where no other bearing plate occurs.

4. Seal cut edges of fire retardant treated wood materials with a certified acceptable sealer.

Project# 542-15-204

542-15-204 06 20 00 - 11

5. Coordinate with plumbing and electrical work for installation of fixtures and service connections in millwork items.

6. Plumb and level items unless shown otherwise.

7. Nail finish at each blocking, lookout, or other nailer and intermediate points; toggle or expansion bolt in place where nails are not suitable.

8. Apply adhesive uniformly for full contact between material and substrate.

B. Shelves:

1. Install mounting strip at back wall and end wall for shelves in closets where shown secured with toggle bolts at each end, not over

600 mm (24 inch) centers between ends.

a. Nail Shelf to mounting strip at ends and to back wall strip at not over 900 mm (36 inches) on center.

b. Install metal bracket, ANSI A156.16, B04041, not over 1200 mm

(4 feet) centers when shelves exceed 1800 mm (6 feet) in length.

c. Install metal bracket, ANSI A156.16, B04051, not over 1200 mm

(4 feet) on centers where shelf length exceeds 1800 mm (6 feet) in length with metal rods, clothes hanger bars ANSI A156.16, L03131, of required length, full length of shelf.

2. Install vertical slotted shelf standards to studs with toggle bolts through each fastener opening. Double slotted shelf standards is acceptable where adjacent shelves terminate.

a. Install brackets providing supports for shelf not over 900 mm

(36 inches) on center and within 13 mm (1/2 inch) of shelf end unless shown otherwise.

b. Install shelves on brackets so front edge is restrained by bracket.

C. Install with butt joints in straight runs and miter at corners.

3.3 CLEANING

A. Remove excess adhesive before adhesive sets.

B. Clean exposed surfaces. Remove contaminants and stains.

C. Touch up damaged factory finishes.

1. Repair painted surfaces with touch up primer.

Project# 542-15-204

542-15-204 06 20 00 - 12

3.4 PROTECTION

A. Protect finish carpentry from traffic and construction operations.

B. Cover finish carpentry with reinforced kraft paper, and plywood or hardboard.

C. Remove protective materials immediately before acceptance.

D. Repair damage.

- - - E N D - - -