This document is a Capabilities Design Review (CDR) presentation for the VAMC Canandaigua Radio System Upgrade Project, prepared by Cynergy Professional Systems and Motorola Solutions and updated December 9, 2024.

The project involves designing and implementing a new ASTRO 25 P25-compliant radio communications system for the VA Medical Center in Canandaigua, New York. The proposed solution includes an ASTRO 25 K1 Core system with distributed architecture and IP-based addressing to provide secure voice communications. Key system components include three MCC 7500E dispatch consoles (located in Building 37 main dispatch and Building 16 fire dispatch), four GTR 8000 repeaters (for Fire, Police, EMS, and Ground Transport), APX consolettes for interoperability with Rochester PD and Ontario County, and subscriber equipment across five user groups: Fire Department (15 APX 8000 portables, 3 APX 8500 mobiles, 1 APX 8500 base station); Police Department (25 APX 8000 portables, 4 APX 8500 mobiles); Engineering Shops (35 APX N30 portables, 1 APX 4500 base station); Grounds and Transportation (5 APX N30 portables, 6 APX 4500 mobiles); and Nursing Staff (10 APX N30 portables). System frequencies include Transportation RX 169.0000 MHz TX 163.3625 MHz, Fire RX 172.6875 MHz TX 164.0625 MHz, Police RX 171.1500 MHz TX 169.5750 MHz, and Maintenance RX 170.1875 MHz TX 163.000 MHz. Supporting infrastructure includes Verint logging recorder capability for 6 LMR talk groups and 3 LMR channels, UPS backup power, GPS and tri-band omnidirectional antennas on Buildings 2 and 37, and extensive networking requiring minimum latency of 20 milliseconds, jitter less than 20 milliseconds, and packet loss below 0.02%. The project schedule extends from October 3, 2024 project kickoff through final acceptance on July 29, 2025, with installation phases occurring May 30 through June 18, 2025, and system optimization, testing, training, and acceptance activities completing in July 2025. Customer responsibilities include providing facility space, dedicated 20-amp 120V power circuits, CAT6 ethernet cabling or fiber connectivity between buildings, HVAC maintenance, grounding infrastructure, roof penetrations for antenna lines, and network demarc access within 20 feet of equipment areas.

View the file

Other files for this federal contract opportunity

Other files attached to J059--FY27 SERVICE - Motorola LMR Service and Maintenance (Base plus 4) Canandaigua VA Medical Center, Canandaigua, NY, newest first.
File Type Posted
36C24226Q0812 0003.pdf PDF
36C24226Q0812 0002.pdf PDF
36C24226Q0812 0001 REVISED.pdf PDF
36C24226Q0812 0001.docx DOCX document
36C24226Q0812 Solicitation.pdf PDF
36C24226Q0812_2.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VAMC Canandaigua Canandaigua, New York Oct 18, 2024 Updated Dec 9, 2024

VAMC Canandaigua Radio System Upgrade

Project CDR

Agenda

● Project Team Introduction

● System Overview

● Solution Design Assumptions and Clarifications

● Subscribers

● VA Canandaigua Frequencies

● Dispatch Overview

● Equipment Location

○ Racks

○ Antennas

● Network Design

● Project Schedule

Project Team

● Steve Appling – Cynergy Program Manager

● Wesley Pellum – Motorola Project Manager Team Lead

● Jess Jenkins - Motorola Project Manager

● JeVaughn Julius - Motorola Systems Engineer

● Ali Devine– Motorola Account Manager

● Carol Rea – Motorola Customer Support Manager

● Roman Nevarez – Motorola Associate Customer Support Manager

● John Morgan - Motorola Regional Services Manager

● Javier Rodriguez - Motorola Engineering Manager

System Overview After carefully reviewing your requirements for improved radio communications, Motorola Solutions, Inc. (Motorola Solutions) has prepared this proposal to provide Canandaigua VA with a new K Core system.

The proposed ASTRO 25 system builds upon Motorola Solution’s ASTRO 25 architecture by combining the open standards of P25 with distributed architecture and IP-based addressing. The system will provide Canandaigua VA with a secure voice communications platform, and provide a standardized and secure communications system.

System Overview: Block Diagram Option 2 (Selected)

System Overview: Equipment Bldg. 37 - IT Room

• ASTRO 25 K1 Core

• Unified Event Manager (UEM)/Configuration Manager (CM) Workstation

■ KVM with PC

• (1) Verint Logging Recorder

■ Capable of recording 6 LMR Talk Groups and 3 LMR channels

• (1) Playback Workstation

• (1) Archiving Interface Server (AIS)

• (1) TRAK server for time synchronization

Bldg. 37 - Dispatch/Dispatch Room

• (3) CCHub MCC 7500E Dispatch Consoles

• (1) Conventional Channel Gateway (CCGW)

• (2) APX Consolettes for interop to Rochester PD and Ontario County

• (1) Short Haul Control Station Combiner (CSC)

■ Antenna system, including (1) all band omnidirectional antenna

System Overview: Equipment

Bldg. 16 – Fire Dispatch

• (1) CCHub MCC 7500E Dispatch Consoles

Bldg. 2 - Penthouse

• (4) GTR 8000 Base Radios - Fire, PD, EMS, & Ground Transport

■ 4-Channel Receiver Multicoupler/Transmit Combiner

■ Antenna system, including (2) omnidirectional antennas

• (1) 2700W, 17 min runtime, tower soft-wired UPS

• (1) Core LAN Switch 01

• (1) Core Router

System EquipmentDevice Name Function

VHF APX

Consolettes

Provides dispatch and also allows interoperability with other agencies.

GTR 8000 Repeater High power transceiver which provides wide-area coverage to support voice communications for subscribers.

Combiner Allows multiple transmitters to share an antenna.

Multicoupler Allows multiple receivers to share one antenna.

Backhaul Switch Acts as an interface to remotes site via the backhaul links.

System Equipment Device Name Function

Site LAN Switch Serves as central connection point for Ethernet devices at a site.

Remote

TRAK 9100

Provides timing for RF devices at the Remote site to synchronize simulcast transmissions.

Short Haul Combiner

That can combine multiple control and despatch centre operators' radios, or multiple point-to-point link radios, into a single antenna.

Uninterruptible Power Supply

(UPS)

Allows equipment to keep running for at least a short time when incoming power is interrupted.

Device Name Function

DSC 8000

Manages the radio site and site resources. It assigns voice and data channels, monitors alarms, and provides frequency reference to the base stations.

Equipment Power Chart

MCC 7500E Dispatch Sites

Motorola Solutions included the MCC 7500E dispatch console to provide VA Canandaigua with the confidence of state-of-the-art secure communications, seamless IP-based connectivity, flexible system architecture with scalable components, and centralized console management.

MCC 7500E

System Architecture - Unified Event Manager (UEM)

The UEM provides system administrators a single interface to view the health of their system infrastructure. Drill down from a high-level dashboard to identify the finest component-level alarm, view metering data and access environmental status and controls.

Unified Event Manager

Verint Recording for Public Safety solutions is a channel-based logging recorder solution that helps critical infrastructure public safety answering points (PSAP) record various forms of media, such as emergency calls, radio communications, and more, which are critical to incident management and after action reviews.

Verint Logging Recorder Solution

Subscribers Motorola Systems Engineer─ JeVaughn Julius

System Overview: Subscribers Subscribers:

• Fire Department

■ (15) APX 8000 portables w/ chargers and RSMs

■ (3) APX 8500 mobiles

■ (1) APX 8500 base station

• Police Department

■ (25) APX 8000 portables w/ chargers and RSMs

■ (4) APX 8500 mobiles

• Engineering Shops

■ (35) APX N30 portables w/ chargers

■ (1) APX 4500 base station

• Grounds and transportation

■ (5) APX N30 portables w/ chargers

■ (6) APX 4500 mobiles

• Nursing Staff

■ (10) APX N30 portables w/ chargers

Device Name Function

APX 8000

A 4-in-1 radio that offers limitless interoperability, the clearest, loudest audio and seamless Wi-Fi® connectivity. The compact, rugged and secure APX 8000™ redefines mission critical communications.

APX 8500 mobiles

The APX 8500 all-band mobile radio combines unlimited interoperability, secure Wi-Fi connectivity, integrated bluetooth and purpose-built design, enabling ease of installation and removal.

APX 8500 base station

The APX 8500 High Power variant delivers high transmitter power, for extraordinary reach and coverage. It's ideal for incident commanders who need to coordinate multiple teams across different frequency bands - especially in situations where network infrastructure is unavailable.

APX N30 portables

APX N30 connects your teams in public works or other municipal roles to reliable P25 radio communications with all the essential features they need and nothing they don’t ﹘ delivering APX performance in a pared down, cost effective package.

APX 4500 mobiles

The APX 4500 brings together powerful technology in a compact, rugged, mobile radio that's easy on your budget. It seamlessly unifies public works, utility, rural public safety and transportation users to first responders so they can communicate effectively in the moments that matter.

4500 base station The compact form factor simplifies vehicle installation. Integrated hardware encryption protects your mission-critical communication.

VA Canandaigua Frequencies

Motorola System Engineer ─ JeVaughn Julius

Transportation:

RX: 169.0000 MHz TX:163.3625 MHz

Fire:

RX: 172.6875 MHz TX: 164.0625 MHz

Police:

RX: 171.1500 MHz TX: 169.5750 MHz

Maintenance:

RX: 170.1875 MHz TX: 163.000 MHz

VA Canandaigua Frequencies

DISPATCH LOCATION

Building 37- Dispatch Room

1) Building 37- Dispatch Room will house three (3) Dispatch console.

2) One Verint Playback station will be house in dispatch room for instant recording playback.

3) Space will needed to accommodate ALL new equipments.

Building 16- Fire Dispatch

1) Building 16- Fire Dispatch Room will house one (1) Dispatch console.

2) Space will needed to accommodate ALL new equipment.

Customer to provide the following:

1. Space – Space to accommodate dispatch console. Space should be available in front and in back to service equipment.

2. Power – One (1) dedicated 20A (120V) circuits within 3 feet of console equipment.

3. Connectivity - Three (3) CAT6 ethernet cables from Building 37 Dispatch Room to Core LAN Switch located in IT Room

4. HVAC - Customer to provide air conditioning and heating to maintain room air temperature within equipment specifications.

Building 37 Dispatch Install Requirements

1. Space – Space to accommodate dispatch console. Space should be available in front and in back to service equipment.

2. Power – One (1) dedicated 20A (120V) circuits within 3 feet of console equipment.

3. Connectivity - One (1) Fiber Pair along with media converters to connect dispatch console to core LAN switch located in Building 37 IT Room.

4. HVAC - Customer to provide air conditioning and heating to maintain room air temperature within equipment specifications.

5. Penetration- Customer to provide new or existing penetration for new antenna coax line (if needed).

Building 16 Dispatch Install Requirements

RACK LOCATION

Rack 3 required for GTR8000’s

& UPS

Rack

Rack

Proposed Rack layout

Building 37- Server Room

1) Building 37- Server Room will house the two racks. Current rack size are 6 ½ ft.

a) Rack 1 will have the core system.

b) Rack 2 will house all the APX consolette

1) One (1) New ground bar will need to be installed.

1) Four (4) new outlet will be installed above the racks.

Building 2- Penthouse

1) Building 2- Penthouse will house two racks.

a) Rack 1 will have all the GTR8000

Repeaters

b) Rack 2 will house the combiner/multicoupler equipment.

c) UPS will be located bottom of Rack 1 or

Rack 2.

d) Multicoupler are standalone unit.

1. Space – Space to accommodate cabinet/rack. Three (3) feet of space should be available in front and in back to service equipment.

2. Power – Four (4) dedicated 20A (120V) circuits within 3 feet of cabinet unit.

3. Grounding – Grounding (Ground Bus Bar) inside the equipment room.

4. Connectivity - Three (3) CAT6 ethernet cables from Building 37 Dispatch Room to Penthouse Building 2.

5. HVAC - Customer to provide air conditioning and heating to maintain room air temperature within equipment specifications.

6. Penetration- Customer to provide new or existing penetration for new coax line and GPS.

Install Requirements

ANTENNA SITE

EQUIPMENT

Equipment

OMNI, RUGGED MEANDER

COLLINEAR

QTY 2

Band VHF

Model DSCOL51174 Bandwidth

(MHz)

162-174MHZ

Gain (dB) 0

Weight (lbs) 24 lbs. (approx.)

Length (ft) 7 feet (approx) Location Building 2- Penthouse

Rooftop - Antenna Specifications

Rooftop - Proposed Antenna Locations

1) New location proposed would have shorter transmission line run that would go directly to the Penthouse.

Transmission run: ~20ft

⅞ cable dB of cable loss: 0.09 dB loss per 100ft: 0.443

1) Antenna location was change since original location would have transmission of ~300-350 ft run from building 1 to building 2.

Transmission run: 350ft max

⅞ cable dB of cable loss: 1.55 dB loss per 100ft: 0.443

Interoperable

Antenna System

QTY 1

Band Tri-Band

Bandwidth (MHz)

VHF, UHF & 7/800 MHz

Gain (dB) Unity

Weight (lbs) 10 lbs. (approx.)

Length (ft) 3 feet (approx) Location Building 37

Rooftop - Antenna Specifications

Rooftop - Proposed Antenna Locations

1) New location proposed would have shorter transmission line run that would go directly to the server room.

Transmission run: ~50ft dB of cable loss: 0.22 dB loss per 100ft: 0.443

1) Antenna location was change since original location would have transmission of ~200-300 ft run.

Transmission run: 300ft dB of cable loss: 1.33 dB loss per 100ft: 0.443

Antenna

Interoperable

Antenna System

QTY 1 (2 Pairs)

Band Tri-band

Bandwidth (MHz)

Gain (dB) 35dB

Weight (lbs) -

Length (ft) 4 inches Location Building 37

Rooftop - GPS Antenna Specifications

Rooftop - Proposed GPS Antenna Location

1) GPS Antenna will be also placed on the pole or even wall mounted.

1) Lighting suppressor will be added to prevent damages to antenna.

1) Conduit might be replaced with bigger size to accommodate all transmission lines needed.

Rooftop - Customer Requirements

Customer to provide the following:

1. Space – Space to mount all outdoor antennas.

2. Grounding – Customer to provide grounding point (Ground Bus Bar) on rooftop near antenna locations.

3. Penetration- Customer to provide new or existing penetration for new antenna coax lines.

NETWORK DESIGN &

CONFIGURATION

1. Connectivity: Ethernet links are required to support connectivity (10/100/1000BASE T Ethernet, CAT5e or better cabling, and Full Duplex connections).

• Layer 2 (Metro Ethernet) or Layer 3 (MPLS) supported

2. Network Demarc: Access to customer’s network must be provided within equipment area (<20ft).

3. Bandwidth (Throughput): Network must provide the minimum CIR to ensure voice quality. Bandwidth can be provided on request.

4. Latency (Packet Delay): Network must provide less than 20 ms of latency (end-to-end) to ensure voice quality.

5. Jitter (Variation in latency): Network must provide less than 20 ms of jitter to ensure voice quality.

The 20 ms is a 99th percentile value and is based on Y.1541 method of calculation.

6. Packet Loss: Network must provide less than 0.02% of pack loss (end-to-end) to ensure voice quality.

7. Connectivity- Three (3) CAT 6 ethernet cable from Lan switch to console from Dispatch room to IT Server Room. One (1) Fiber pair and media converters from Building 16 Console to IT Server Room in Building 37.

Network ─ General Requirements

Project Schedule

Questions/Discussion ?

Review of Follow-up & Action Items