This document is a Special Notice for a sole source contract issued by the Department of Veterans Affairs (VA) Albany VAMC. The VA intends to award a contract to Olympus America, Inc. for a Cystoscopy Resection Tray (Solicitation Number: 36C24226Q0223), with a response deadline of 12-26-2025 at 16:00 Eastern Time. The specialized medical equipment consists of a cystoscopy resection set that allows surgeons to visualize and access the bladder and lower urinary tract using a rigid cystoscope and resectoscope assembly, capable of performing diagnostic and therapeutic urologic procedures such as transurethral resection of bladder tumors (TURBT), prostate resection (TURP), biopsies, and tissue coagulation. The ST-CR2 resection tray is designed to ensure proper protection, organization, and sterilization of components, maintaining instrument alignment and compatibility with Olympus resection instruments.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Special Notice Special Notice

SUBJECT*
Cystoscopy Resection Sets-Intent to Sole Source

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
14424
SOLICITATION NUMBER*
36C24226Q0223
RESPONSE DATE/TIME/ZONE
12-26-2025 16:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
PRODUCT SERVICE CODE*
6515
NAICS CODE*
339112

CONTRACTING OFFICE ADDRESS

Department of Veterans Affairs 400 Fort Hill Ave.

Canandaigua NY 14424

POINT OF CONTACT*

Contract Specialist Barry Sawyer Barry.Sawyer@va.gov 585-393-8563

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov/
URL DESCRIPTION
VA Homepage

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

This is a notice of intent to award a sole source contract and is not a request for quotes.

The Department of Veterans Affairs Albany VAMC intends to award a Sole Source open market action contract for the purchase of a Cystoscopy Resection Tray.

Name of Contractor:
Olympus America, Inc.
Street Address:
3500 Corporate Parkway, P.O. Box 610
City, State, Zip:
Center Valley, PA 18034-0610

The cystoscopy resection set operates by allowing the surgeon to visualize and access the bladder and lower urinary tract using a rigid cystoscope and resectoscope assembly. The system combines optical imaging, fluid irrigation, and electrosurgical energy delivery to perform diagnostic and therapeutic urologic procedures such as transurethral resection of bladder tumors (TURBT), transurethral resection of the prostate (TURP), biopsy, coagulation, and removal of lesions or foreign bodies. The rigid cystoscope provides direct visualization through an optical telescope connected to the facility’s camera system and video tower. Continuous irrigation flows through the resectoscope sheath to maintain a clear field of view during surgery.

A working element within the resectoscope advances and retracts an electrosurgical cutting or coagulation electrode. The surgeon activates the electrode using an electrosurgical generator to precisely resect or coagulate tissue under direct visualization. The mechanical movement of the working element, combined with the stability of the resectoscope sheath, allows for controlled tissue removal while minimizing trauma.

The ST-CR2 resection tray supports safe operation by ensuring proper protection, organization, and validated sterilization of all components. The tray maintains instrument alignment, spacing, and immobilization during reprocessing cycles, preserving optical accuracy, electrosurgical performance, and mechanical functionality. The tray’s design ensures compatibility with Olympus resection instruments and compliance with OEM reprocessing Instructions for Use (IFUs). All OEM components necessary to perform rigid cystoscopy and transurethral resection procedures.

These items ensure full compatibility with the facility’s existing endoscopic platform.

See attached document: P03-Single Source Justification MPT to SAT- cystoscopy trays.