36C24225Q0506.docx
DOCX document 195 KB Posted
- Solicitation number
- 36C24225Q0506
About this file
This document is a Request for Quotations (RFQ) for an Indefinite Delivery/Indefinite Quantity (ID/IQ) contract for demolition and abatement services at the VA Western New York Healthcare System (VAWNYHS). The contract will cover work at the Buffalo VA Medical Center and Batavia VA Medical Center, with a five-year term from July 1, 2025, to June 30, 2030. The total contract value is not to exceed $1.5 million, with a minimum order of $10,000 over the contract's lifetime.
The solicitation is set aside specifically for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). Contractors must have an active New York State Department of Labor Asbestos Handling License and technicians must possess a valid Asbestos Certificate. The contract requires emergency response capabilities, with contractors expected to respond within 30 minutes and be on-site within two hours when called. Key services include various demolition and abatement activities such as flooring removal, wall and ceiling demolition, asbestos containment, and hazardous material removal. Evaluation will be based on technical capability, past performance, and pricing, with a focus on the contractor's ability to meet infection control and safety requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24225Q0506 0001.docx | DOCX document | |
| WD Genesee.docx | DOCX document | |
| 20240125 Line-Item Bid Sheet DA IDIQ.xlsx | XLSX spreadsheet | |
| WD Erie.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PAGE OF PAGES
THIS RFQ IS
IS
NOT A SMALL BUSINESS SET-ASIDE
1. REQUEST NO.
2. DATE ISSUED
3. REQUISITION/PURCHASE REQUEST NO.
4.
CERT. FOR NAT. DEF.
RATING
UNDER BDSA REG. 2
AND/OR DMS REG. 1
5A. ISSUED BY
6. DELIVER BY (Date) 5B. FOR INFORMATION CALL: (No collect calls)
7. DELIVERY
NAME
TELEPHONE NUMBER
FOB DESTINATION
(See Schedule)
OTHER
AREA
CODE
NUMBER
9. DESTINATION
a. NAME OF CONSIGNEE
8. TO:
a. NAME
b. COMPANY
b. STREET ADDRESS
c. STREET ADDRESS
c. CITY
d. CITY
e. STATE
f. ZIP CODE
d. STATE
e. ZIP CODE 10.
PLEASE FURNISH QUOTATIONS TO THE ISSUING OFFICE ON
OR BEFORE CLOSE OF BUSINESS (Date) This is a request for information, and quotations furnished are not offers. If you are unable to quote, please so indicate on this form and return it. This request does not commit the Government to pay any costs incurred in the preparation of the submission of this quotation or to contract for supplies or services. Supplies are of domestic origin unless otherwise indicated by quoter. Any representations and/or certifications attached to this Request for Quotations must be completed by the quoter.
ITEM NO.
SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
(a) (b) (c) (d) (e) (f)
a. 10 CALENDAR DAYS %
b. 20 CALENDAR DAYS %
c. 30 CALENDAR DAYS %
d. CALENDAR DAYS
NUMBER
PERCENTAGE
NOTE: Additional provisions and representations are are not attached.
13. NAME AND ADDRESS OF QUOTER
14. SIGNATURE OF PERSON AUTHORIZED TO SIGN QUOTATION
15. DATE OF QUOTATION
a. NAME OF QUOTER
b. STREET ADDRESS
16. SIGNER
a. Name (Type or print)
b. TELEPHONE
c. COUNTY
AREA CODE
d. CITY
e. STATE
f. ZIP CODE
c. TITLE (Type or print)
NUMBER
IMPORTANT:
11. SCHEDULE (Include applicable Federal, State and local taxes)
12. DISCOUNT FOR PROMPT PAYMENT
(THIS IS NOT AN ORDER)
AUTHORIZED FOR LOCAL REPRODUCTION
STANDARD FORM 18
REV. 6-95)
Previous edition not usable Prescribed by GSA-FAR (48 CFR) 53.215-1(a)
REQUEST FOR QUOTATIONS
X 36C24225Q0506 -2025 Department of Veterans Affairs Network Contracting Office (NCO) 2 2875 Union Road Suite 3500 Cheektowaga NY 14227
SPIVACK, MICHAEL
716-862-1461 X22458 Department of Veterans Affairs WNY Healthcare System 3495 Bailey Avenue Buffalo
NY
14215 05-14-2025 See CONTINUATION Page This Statement of Work is for an Indefinite Delivery/ Indefinite Quantity (ID/IQ) Contract for demolition and abatement efforts supporting construction and repair services at VAWNYHS Medical Centers. These services shall be provided on an as needed basis, for a five-year term.
VAWNYHS has various sized projects that require a Contractor to perform the demolition and abatement portion of this work necessary to accomplish this goal.
For detailed requirements, please see attached scope of work.
Please send responses to Michael Spivack at Michael.Spivack@va.gov by 10:00 EST on 0 /2025.
This solicitation is set aside for SDVOSB companies.
X Table of Contents
| A.1 SF 18 REQUEST FOR QUOTATIONS | 1 |
| A.2 PRICE/COST SCHEDULE | 4 |
| ITEM INFORMATION | 4 |
| INSTRUCTIONS, CONDITIONS AND OTHER STATEMENTS TO BIDDERS/OFFERORS | 44 |
| 2.1 52.201-1 ACQUISITION 360: VOLUNTARY SURVEY (SEP 2023) | 44 |
| 2.2 52.216-1 TYPE OF CONTRACT (APR 1984) | 44 |
| 2.3 52.222-5 CONSTRUCTION WAGE RATE REQUIREMENTS—SECONDARY SITE OF THE WORK (MAY 2014) | 44 |
| 2.4 52.222-23 NOTICE OF REQUIREMENT FOR AFFIRMATIVE ACTION TO ENSURE EQUAL EMPLOYMENT OPPORTUNITY FOR CONSTRUCTION (FEB 1999) | 45 |
| 2.5 52.225-10 NOTICE OF BUY AMERICAN REQUIREMENT—CONSTRUCTION MATERIALS (MAY 2014) | 46 |
| 2.6 52.228-1 BID GUARANTEE (SEP 1996) | 47 |
| 2.7 52.228-17 INDIVIDUAL SURETY—PLEDGE OF ASSETS (BID GUARANTEE) (FEB 2021) | 47 |
| 2.8 52.233-2 SERVICE OF PROTEST (SEP 2006) | 48 |
| 2.9 52.252-1 SOLICITATION PROVISIONS INCORPORATED BY REFERENCE (FEB 1998) | 48 |
| 2.10 VAAR 852.228-72 ASSISTING SERVICE-DISABLED VETERAN-OWNED AND VETERAN-OWNED SMALL BUSINESSES IN OBTAINING BONDS (DEC 2009) | 49 |
| 2.11 VAAR 852.233-70 PROTEST CONTENT/ALTERNATIVE DISPUTE RESOLUTION (OCT 2018) | 49 |
| 2.12 VAAR 852.239-75 INFORMATION AND COMMUNICATION TECHNOLOGY ACCESSIBILITY NOTICE (FEB 2023) | 50 |
| 2.13 VAAR 852.233-71 ALTERNATE PROTEST PROCEDURE (OCT 2018) | 50 |
| REPRESENTATIONS AND CERTIFICATIONS | 51 |
| 3.1 52.204-8 ANNUAL REPRESENTATIONS AND CERTIFICATIONS (JAN 2025) | 51 |
| 3.2 52.204-24 REPRESENTATION REGARDING CERTAIN TELECOMMUNICATIONS AND VIDEO SURVEILLANCE SERVICES OR EQUIPMENT (NOV 2021) | 55 |
| 3.3 52.204-29 FEDERAL ACQUISITION SUPPLY CHAIN SECURITY ACT ORDERS—REPRESENTATION AND DISCLOSURES (DEC 2023) | 57 |
| 3.4 52.209-7 INFORMATION REGARDING RESPONSIBILITY MATTERS (OCT 2018) | 59 |
| 3.5 52.209-13 VIOLATION OF ARMS CONTROL TREATIES OR AGREEMENTS—CERTIFICATION (NOV 2021) | 60 |
| GENERAL CONDITIONS | 63 |
| 4.1 52.204-19 INCORPORATION BY REFERENCE OF REPRESENTATIONS AND CERTIFICATIONS (DEC 2014) | 63 |
| 4.2 52.204-23 PROHIBITION ON CONTRACTING FOR HARDWARE, SOFTWARE, AND SERVICES DEVELOPED OR PROVIDED BY KASPERSKY LAB COVERED ENTITIES (DEC 2023) | 63 |
| 4.3 52.204-30 FEDERAL ACQUISITION SUPPLY CHAIN SECURITY ACT ORDERS—PROHIBITION (DEC 2023) | 64 |
| 4.4 52.209-9 UPDATES OF PUBLICLY AVAILABLE INFORMATION REGARDING RESPONSIBILITY MATTERS (OCT 2018) | 69 |
| 4.5 52.211-10 COMMENCEMENT, PROSECUTION, AND COMPLETION OF WORK (APR 1984) | 70 |
| 4.6 52.216-18 ORDERING (AUG 2020) | 70 |
| 4.7 52.216-19 ORDER LIMITATIONS (OCT 1995) | 70 |
| 4.8 52.216-22 INDEFINITE QUANTITY (OCT 1995) | 71 |
| 4.9 52.219-28 POSTAWARD SMALL BUSINESS PROGRAM REREPRESENTATION (JAN 2025) | 71 |
| 4.10 52.222-40 NOTIFICATION OF EMPLOYEE RIGHTS UNDER THE NATIONAL LABOR RELATIONS ACT (DEC 2010) | 75 |
| 4.11 52.225-9 BUY AMERICAN—CONSTRUCTION MATERIALS (OCT 2022) | 76 |
| 4.12 SUPPLEMENTAL INSURANCE REQUIREMENTS | 81 |
| 4.13 52.252-2 CLAUSES INCORPORATED BY REFERENCE (FEB 1998) | 81 |
| 4.14 VAAR 852.203-70 COMMERCIAL ADVERTISING (MAY 2018) | 84 |
| 4.15 VAAR 852.219-73 VA NOTICE OF TOTAL SET-ASIDE FOR CERTIFIED SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESSES (JAN 2023) (DEVIATION) | 84 |
| 4.16 VAAR 852.219-75 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING—CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION (NOV 2022) | 87 |
| 4.17 VAAR 852.232-72 ELECTRONIC SUBMISSION OF PAYMENT REQUESTS (NOV 2018) | 89 |
| 4.18 VAAR 852.201-70 CONTRACTING OFFICER'S REPRESENTATIVE (DEC 2022) | 90 |
| 4.19 VAAR 852.236-71 SPECIFICATIONS AND DRAWINGS FOR CONSTRUCTION (APR 2019) | 90 |
| 4.20 VAAR 852.236-79 CONTRACTOR PRODUCTION REPORT (APR 2019) | 91 |
| 4.21 VAAR 852.236-80 SUBCONTRACTS AND WORK COORDINATION (APR 2019) | 91 |
| 4.22 VAAR 852.242-70 GOVERNMENT CONSTRUCTION CONTRACT ADMINISTRATION (OCT 2020) | 92 |
| 4.23 VAAR 852.242-71 ADMINISTRATIVE CONTRACTING OFFICER (OCT 2020) | 93 |
| 4.24 VAAR 852.243-70 CONSTRUCTION CONTRACT CHANGES—SUPPLEMENT (SEP 2019) | 93 |
| 4.25 VAAR 852.223-71 SAFETY AND HEALTH (SEP 2019) | 95 |
| 4.26 VAAR 852.228-70 BOND PREMIUM ADJUSTMENT (JAN 2008) | 96 |
| 4.27 VAAR 852.232-70 PAYMENTS UNDER FIXED-PRICE CONSTRUCTION CONTRACTS (WITHOUT NAS– CPM) (NOV 2018) | 96 |
| 4.28 VAAR 852.246-71 REJECTED GOODS (OCT 2018) | 99 |
| 5. SCOPE OF WORK | 100 |
A.2 PRICE/COST SCHEDULE
ITEM INFORMATION
| ITEM NUMBER |
| DESCRIPTION OF SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
GENERAL DEMOLITION ACTIVITIES ARE REQUIRED TO MEET INFECTION CONTROL RISK ASSESSMENT (ICRA) LEVEL 4 FOR WORK INSIDE OF THE HOSPITAL Contract Period: Base POP Begin: 07-01-2025 POP End: 06-30-2026
0001A
| 1.00 |
| SF |
| ___________ |
Removal of existing flooring and associated adhesives (• Subfloor to be free of all residue and ground to a flat, smooth finish)
0001B
| 1.00 |
| SF |
| ___________ |
Removal of partition metal stud and drywall with or without plaster skim coat and flattened expanded metal fastened to metal studs, including demountable partitions and repair damage to other wall surfaces. Remove all debris from Government property.
0001C
| 1.00 |
| SF |
| ___________ |
Removal of drywall with or without plaster skim coat on one side of partition or wall. Remove all debris from Government property.
0001D
| 1.00 |
| SF |
| ___________ |
Removal of wall protection, including but not limited to IPC rigid vinyl sheets and removal of all debris from Government property.
POP Begin: 07-01-2025 and Infirmaries
0001E
| 1.00 |
| SF |
| ___________ |
Removal of masonry style wall, including removal of all debris from Government property.
0001F
| 1.00 |
| SF |
| ___________ |
Removal of existing ceramic, porcelain, or quarry tile (wall and floor) and associated thinset/mortar
0001G
| 1.00 |
| SF |
| ___________ |
Removal of existing flooring and associated adhesives (Subfloor to be free of all residue and ground to a flat, smooth finish)
0001H
| 1.00 |
| SF |
| ___________ |
Remove wall covering, vinyl or fabric, including cleaning of the wall surface and remove from the Government property.
0001I
| 1.00 |
| JB |
| ___________ |
Remove door and frame from masonry type wall. Door and frame shall be removed from Government property unless requested to be returned to the Government.
0001J
| 1.00 |
| JB |
| ___________ |
Remove door and frame from drywall and/or demountable partition. Door and frame shall be removed from Government property unless requested to be returned to the Government.
0001K
| 1.00 |
| JB |
| ___________ |
Remove lockset from existing door and return to the Government.
0001L
| 1.00 |
| SF |
| ___________ |
Remove ceiling tile and suspension system, any type, and remove from the Government property.
0001M
| 1.00 |
| SF |
| ___________ |
Remove ceiling tile only and remove from the Government property.
0001N
| 1.00 |
| SF |
| ___________ |
Remove plaster style or solid ceiling, any type, and remove from Government property
0001O
| 1.00 |
| JB |
| ___________ |
Remove light fixture any type including exit, emergency light.
0001P
| 1.00 |
| JB |
| ___________ |
Remove electrical switch, any type. Remove electrical wall receptacle, any type including wiring up to 50'-0".
0001Q
| 1.00 |
| LF |
| ___________ |
Remove rigid style conduit, including installed feeders (not powered) up to 2 inches in diameter and remove from the Government property.
0001R
| 1.00 |
| LF |
| ___________ |
Remove rigid style conduit, including installed feeders (not powered) larger than 2 inches in diameter and remove from the Government property.
0001S
| 1.00 |
| JB |
| ___________ |
Remove electrical floor receptacle flush or pedestal and provide cap and plug assembly. Remove telephone floor outlet flush or pedestal and provide cap and plug assemble.
0001T
| 1.00 |
| JB |
| ___________ |
Remove electrical floor receptacle flush or pedestal and provide cap and plug assembly. Remove telephone floor outlet flush or pedestal and provide cap and plug assemble.
0001U
| 1.00 |
| JB |
| ___________ |
Removal of furniture, remove from Government property unless requested to be returned to the Government. Price shall be determined by the number of items.
0001V
| 1.00 |
| SF |
| ___________ |
Remove carpet tack-less method, glued down, or carpet tile including cleaning of the floor surface to remove residual glue and remove from the Government property.
0001W
| 1.00 |
| SF |
| ___________ |
Remove carpet pad any type and remove all debris from Government property, including cleaning of the floor surface.
0001X
| 1.00 |
| LF |
| ___________ |
Remove cove base molding or carpet base and remove from the Government property.
0001Y
| 1.00 |
| SF |
| ___________ |
Remove resilient floor tile, including cleaning of the floor surface and remove all debris from Government property.
0001Z
| 1.00 |
| JB |
| ___________ |
Removal of plumbing fixtures, including but not limited to toilets, sinks, urinals, restroom partitions, etc.
0001ZA
| 1.00 |
| LF |
| ___________ |
Removal of abandoned or isolated plumbing supply or return lines smaller than 2 inches in diameter.
0001ZB
| 1.00 |
| LF |
| ___________ |
Removal of abandoned or isolated plumbing supply or return lines greater than 2 inches in diameter.
0001ZC
| 1.00 |
| JB |
| ___________ |
Mobilization/Demobilization fee for all demolition activities.
ABATEMENT DEMOLITION ACTIVITIES ARE REQUIRED TO MEET INFECTION CONTROL RISK ASSESSMENT (ICRA) LEVEL 4 AND '12 NYCRR PART 56' FOR WORK INSIDE OF THE HOSPITAL
0002A
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of flooring and mastic (multiple layers will double the SF).
0002B
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of only flooring (multiple layers will double the SF).
0002C
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of only mastic (multiple layers will double the SF).
0002D
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of carpet.
0002E
| 1.00 |
| LF |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation up to 2 inches in diameter.
0002F
| 1.00 |
| LF |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation between 2 inches - 6 inches in diameter.
0002G
| 1.00 |
| LF |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation larger than 6 inches in diameter.
0002H
| 1.00 |
| JB |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of fittings, saddle blocks, valves, T's or other mechanical appurtenances 2 inches to 6 inches in diameter.
0002I
| 1.00 |
| SF |
| ___________ |
Removal and disposal of lead-based paint from Government property.
0002J
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements of Transite-type materials.
0002K
| 1.00 |
| LF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of Transite-type pipe up to 2 inches in diameter.
0002L
| 1.00 |
| LF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of Transite-type pipe between 2 inches - 6 inches in diameter.
0002M
| 1.00 |
| LF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of Transite-type pipe larger than 6 inches in diameter.
0002N
| 1.00 |
| LF |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation up to 2 inches in diameter.
0002O
| 1.00 |
| LF |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation between 2 inches - 6 inches in diameter.
0002P
| 1.00 |
| LF |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation larger than 6 inches in diameter.
0002Q
| 1.00 |
| JB |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of fittings, saddle blocks, valves, T's or other mechanical appurtenances 2 inches to 6 inches in diameter.
0002R
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of duct insulation.
0002S
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of radiator insulation and mastic.
0002T
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of plaster ceiling/wall.
0002U
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of drywall and/or drywall joint compound.
0002V
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of sprayed on or troweled on surfacing.
0002W
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of miscellaneous material.
0002X
| 1.00 |
| JB |
| ___________ |
Removal and disposal of asbestos containing fire-rated doors (does not require removal from frame).
0002Y
| 1.00 |
| JB |
| ___________ |
Encapsulation of remaining Asbestos Containing Material.
0002Z
| 1.00 |
| JB |
| ___________ |
Enclosure of remaining Asbestos Containing Material.
0002ZA
| 1.00 |
| JB |
| ___________ |
Mobilization/Demobilization fee for all Abatement Activities.
| 1.00 |
| JB |
| ___________ |
Emergency Call-In Service shall respond to that call within thirty (30) minutes and be onsite within two (2) hours ready to mobilize associated with any of the above services.
Rate multiplier for any of the above services to be performed off-hours or during the weekend.
GENERAL DEMOLITION ACTIVITIES ARE REQUIRED TO MEET INFECTION CONTROL RISK ASSESSMENT (ICRA) LEVEL 4 FOR WORK INSIDE OF THE HOSPITAL Contract Period: Option 1 POP Begin: 07-01-2026 POP End: 06-30-2027
1001A
| 1.00 |
| SF |
| ___________ |
Removal of existing flooring and associated adhesives (•Subfloor to be free of all residue and ground to a flat, smooth finish)
1001B
| 1.00 |
| SF |
| ___________ |
Removal of partition metal stud and drywall with or without plaster skim coat and flattened expanded metal fastened to metal studs, including demountable partitions and repair damage to other wall surfaces. Remove all debris from Government property.
1001C
| 1.00 |
| SF |
| ___________ |
Removal of drywall with or without plaster skim coat on one side of partition or wall. Remove all debris from Government property.
1001D
| 1.00 |
| SF |
| ___________ |
Removal of wall protection, including but not limited to IPC rigid vinyl sheets and removal of all debris from Government property.
1001E
| 1.00 |
| SF |
| ___________ |
Removal of masonry style wall, including removal of all debris from Government property.
1001F
| 1.00 |
| SF |
| ___________ |
Removal of existing ceramic, porcelain, or quarry tile (wall and floor) and associated thinset/mortar
1001G
| 1.00 |
| SF |
| ___________ |
Removal of existing flooring and associated adhesives (Subfloor to be free of all residue and ground to a flat, smooth finish)
1001H
| 1.00 |
| SF |
| ___________ |
Remove wall covering, vinyl or fabric, including cleaning of the wall surface and remove from the Government property.
1001I
| 1.00 |
| JB |
| ___________ |
Remove door and frame from masonry type wall. Door and frame shall be removed from Government property unless requested to be returned to the Government.
1001J
| 1.00 |
| JB |
| ___________ |
Remove door and frame from drywall and/or demountable partition. Door and frame shall be removed from Government property unless requested to be returned to the Government.
1001K
| 1.00 |
| JB |
| ___________ |
Remove lockset from existing door and return to the Government.
1001L
| 1.00 |
| SF |
| ___________ |
Remove ceiling tile and suspension system, any type, and remove from the Government property.
POP Begin: 07-01-2026 POP End: 06-30-2027 PRINCIPAL NAICS CODE: 562910 - Remediation Services PRODUCT/SERVICE CODE: Z1DA - Maintenance of Hospitals and Infirmaries
1001M
| 1.00 |
| SF |
| ___________ |
Remove ceiling tile only and remove from the Government property.
1001N
| 1.00 |
| SF |
| ___________ |
Remove plaster style or solid ceiling, any type, and remove from Government property
1001O
| 1.00 |
| JB |
| ___________ |
Remove light fixture any type including exit, emergency light.
1001P
| 1.00 |
| JB |
| ___________ |
Remove electrical switch, any type. Remove electrical wall receptacle, any type including wiring up to 50'-0".
1001Q
| 1.00 |
| LF |
| ___________ |
Remove rigid style conduit, including installed feeders (not powered) up to 2 inches in diameter and remove from the Government property.
1001R
| 1.00 |
| LF |
| ___________ |
Remove rigid style conduit, including installed feeders (not powered) larger than 2 inches in diameter and remove from the Government property.
1001S
| 1.00 |
| JB |
| ___________ |
Remove electrical floor receptacle flush or pedestal and provide cap and plug assembly. Remove telephone floor outlet flush or pedestal and provide cap and plug assemble.
1001T
| 1.00 |
| JB |
| ___________ |
Remove electrical floor receptacle flush or pedestal and provide cap and plug assembly. Remove telephone floor outlet flush or pedestal and provide cap and plug assemble.
1001U
| 1.00 |
| JB |
| ___________ |
Removal of furniture, remove from Government property unless requested to be returned to the Government. Price shall be determined by the number of items.
1001V
| 1.00 |
| SF |
| ___________ |
Remove carpet tack-less method, glued down, or carpet tile including cleaning of the floor surface to remove residual glue and remove from the Government property.
1001W
| 1.00 |
| SF |
| ___________ |
Remove carpet pad any type and remove all debris from Government property, including cleaning of the floor surface.
1001X
| 1.00 |
| LF |
| ___________ |
Remove cove base molding or carpet base and remove from the Government property.
1001Y
| 1.00 |
| SF |
| ___________ |
Remove resilient floor tile, including cleaning of the floor surface and remove all debris from Government property.
1001Z
| 1.00 |
| JB |
| ___________ |
Removal of plumbing fixtures, including but not limited to toilets, sinks, urinals, restroom partitions, etc.
1001ZA
| 1.00 |
| LF |
| ___________ |
Removal of abandoned or isolated plumbing supply or return lines smaller than 2 inches in diameter.
1001ZB
| 1.00 |
| LF |
| ___________ |
Removal of abandoned or isolated plumbing supply or return lines greater than 2 inches in diameter.
1001ZC
| 1.00 |
| JB |
| ___________ |
Mobilization/Demobilization fee for all demolition activities.
ABATEMENT DEMOLITION ACTIVITIES ARE REQUIRED TO MEET INFECTION CONTROL RISK ASSESSMENT (ICRA) LEVEL 4 AND '12 NYCRR PART 56' FOR WORK INSIDE OF THE HOSPITAL
1002A
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of flooring and mastic (multiple layers will double the SF).
1002B
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of only flooring (multiple layers will double the SF).
1002C
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of only mastic (multiple layers will double the SF).
1002D
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of carpet.
1002E
| 1.00 |
| LF |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation up to 2 inches in diameter.
1002F
| 1.00 |
| LF |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation between 2 inches - 6 inches in diameter.
1002G
| 1.00 |
| LF |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation larger than 6 inches in diameter.
1002H
| 1.00 |
| JB |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of fittings, saddle blocks, valves, T's or other mechanical appurtenances 2 inches to 6 inches in diameter.
1002I
| 1.00 |
| SF |
| ___________ |
Removal and disposal of lead-based paint from Government property.
1002J
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements of Transite-type materials.
1002K
| 1.00 |
| LF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of Transite-type pipe up to 2 inches in diameter.
1002L
| 1.00 |
| LF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of Transite-type pipe between 2 inches - 6 inches in diameter.
1002M
| 1.00 |
| LF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of Transite-type pipe larger than 6 inches in diameter.
1002N
| 1.00 |
| LF |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation up to 2 inches in diameter.
1002O
| 1.00 |
| LF |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation between 2 inches - 6 inches in diameter.
1002P
| 1.00 |
| LF |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation larger than 6 inches in diameter.
1002Q
| 1.00 |
| JB |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of fittings, saddle blocks, valves, T's or other mechanical appurtenances 2 inches to 6 inches in diameter.
1002R
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of duct insulation.
1002S
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of radiator insulation and mastic.
1002T
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of plaster ceiling/wall.
1002U
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of drywall and/or drywall joint compound.
1002V
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of sprayed on or troweled on surfacing.
1002W
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of miscellaneous material.
1002X
| 1.00 |
| JB |
| ___________ |
Removal and disposal of asbestos containing fire-rated doors (does not require removal from frame).
1002Y
| 1.00 |
| JB |
| ___________ |
Encapsulation of remaining Asbestos Containing Material.
1002Z
| 1.00 |
| JB |
| ___________ |
Enclosure of remaining Asbestos Containing Material.
1002ZA
| 1.00 |
| JB |
| ___________ |
Mobilization/Demobilization fee for all Abatement Activities.
| 1.00 |
| JB |
| ___________ |
Emergency Call-In Service shall respond to that call within thirty (30) minutes and be onsite within two (2) hours ready to mobilize associated with any of the above services.
Rate multiplier for any of the above services to be performed off-hours or during the weekend.
GENERAL DEMOLITION ACTIVITIES ARE REQUIRED TO MEET INFECTION CONTROL RISK ASSESSMENT (ICRA) LEVEL 4 FOR WORK INSIDE OF THE HOSPITAL Contract Period: Option 2 POP Begin: 07-01-2027 POP End: 06-30-2028
2001A
| 1.00 |
| SF |
| ___________ |
Removal of existing flooring and associated adhesives (Subfloor to be free of all residue and ground to a flat, smooth finish)
2001B
| 1.00 |
| SF |
| ___________ |
Removal of partition metal stud and drywall with or without plaster skim coat and flattened expanded metal fastened to metal studs, including demountable partitions and repair damage to other wall surfaces. Remove all debris from Government property.
2001C
| 1.00 |
| SF |
| ___________ |
Removal of drywall with or without plaster skim coat on one side of partition or wall. Remove all debris from Government property.
2001D
| 1.00 |
| SF |
| ___________ |
Removal of wall protection, including but not limited to IPC rigid vinyl sheets and removal of all debris from Government property.
2001E
| 1.00 |
| SF |
| ___________ |
Removal of masonry style wall, including removal of all debris from Government property.
2001F
| 1.00 |
| SF |
| ___________ |
Removal of existing ceramic, porcelain, or quarry tile (wall and floor) and associated thinset/mortar
2001G
| 1.00 |
| SF |
| ___________ |
Removal of existing flooring and associated adhesives (Subfloor to be free of all residue and ground to a flat, smooth finish)
2001H
| 1.00 |
| SF |
| ___________ |
Remove wall covering, vinyl or fabric, including cleaning of the wall surface and remove from the Government property.
2001I
| 1.00 |
| JB |
| ___________ |
Remove door and frame from masonry type wall. Door and frame shall be removed from Government property unless requested to be returned to the Government.
2001J
| 1.00 |
| JB |
| ___________ |
Remove door and frame from drywall and/or demountable partition. Door and frame shall be removed from Government property unless requested to be returned to the Government.
2001K
| 1.00 |
| JB |
| ___________ |
Remove lockset from existing door and return to the Government.
2001L
| 1.00 |
| SF |
| ___________ |
Remove ceiling tile and suspension system, any type, and remove from the Government property.
2001M
| 1.00 |
| SF |
| ___________ |
Remove ceiling tile only and remove from the Government property.
2001N
| 1.00 |
| SF |
| ___________ |
Remove plaster style or solid ceiling, any type, and remove from Government property
2001O
| 1.00 |
| JB |
| ___________ |
Remove light fixture any type including exit, emergency light.
2001P
| 1.00 |
| JB |
| ___________ |
Remove electrical switch, any type. Remove electrical wall receptacle, any type including wiring up to 50'-0".
2001Q
| 1.00 |
| LF |
| ___________ |
Remove rigid style conduit, including installed feeders (not powered) up to 2 inches in diameter and remove from the Government property.
2001R
| 1.00 |
| LF |
| ___________ |
Remove rigid style conduit, including installed feeders (not powered) larger than 2 inches in diameter and remove from the Government property.
2001S
| 1.00 |
| JB |
| ___________ |
Remove electrical floor receptacle flush or pedestal and provide cap and plug assembly. Remove telephone floor outlet flush or pedestal and provide cap and plug assemble.
2001T
| 1.00 |
| JB |
| ___________ |
Remove electrical floor receptacle flush or pedestal and provide cap and plug assembly. Remove telephone floor outlet flush or pedestal and provide cap and plug assemble.
2001U
| 1.00 |
| JB |
| ___________ |
Removal of furniture, remove from Government property unless requested to be returned to the Government. Price shall be determined by the number of items.
2001V
| 1.00 |
| SF |
| ___________ |
Remove carpet tack-less method, glued down, or carpet tile including cleaning of the floor surface to remove residual glue and remove from the Government property.
2001W
| 1.00 |
| SF |
| ___________ |
Remove carpet pad any type and remove all debris from Government property, including cleaning of the floor surface.
2001X
| 1.00 |
| LF |
| ___________ |
Remove cove base molding or carpet base and remove from the Government property.
2001Y
| 1.00 |
| SF |
| ___________ |
Remove resilient floor tile, including cleaning of the floor surface and remove all debris from Government property.
2001Z
| 1.00 |
| JB |
| ___________ |
Removal of plumbing fixtures, including but not limited to toilets, sinks, urinals, restroom partitions, etc.
2001ZA
| 1.00 |
| LF |
| ___________ |
Removal of abandoned or isolated plumbing supply or return lines smaller than 2 inches in diameter.
2001ZB
| 1.00 |
| LF |
| ___________ |
Removal of abandoned or isolated plumbing supply or return lines greater than 2 inches in diameter.
2001ZC
| 1.00 |
| JB |
| ___________ |
Mobilization/Demobilization fee for all demolition activities.
ABATEMENT DEMOLITION ACTIVITIES ARE REQUIRED TO MEET INFECTION CONTROL RISK ASSESSMENT (ICRA) LEVEL 4 AND '12 NYCRR PART 56' FOR WORK INSIDE OF THE HOSPITAL
2002A
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of flooring and mastic (multiple layers will double the SF).
2002B
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of only flooring (multiple layers will double the SF).
2002C
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of only mastic (multiple layers will double the SF).
2002D
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of carpet.
2002E
| 1.00 |
| LF |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation up to 2 inches in diameter.
2002F
| 1.00 |
| LF |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation between 2 inches - 6 inches in diameter.
2002G
| 1.00 |
| LF |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation larger than 6 inches in diameter.
2002H
| 1.00 |
| JB |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of fittings, saddle blocks, valves, T's or other mechanical appurtenances 2 inches to 6 inches in diameter.
2002I
| 1.00 |
| SF |
| ___________ |
Removal and disposal of lead-based paint from Government property.
2002J
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements of Transite-type materials.
2002K
| 1.00 |
| LF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of Transite-type pipe up to 2 inches in diameter.
2002L
| 1.00 |
| LF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of Transite-type pipe between 2 inches - 6 inches in diameter.
2002M
| 1.00 |
| LF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of Transite-type pipe larger than 6 inches in diameter.
2002N
| 1.00 |
| LF |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation up to 2 inches in diameter.
2002O
| 1.00 |
| LF |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation between 2 inches - 6 inches in diameter.
2002P
| 1.00 |
| LF |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation larger than 6 inches in diameter.
2002Q
| 1.00 |
| JB |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of fittings, saddle blocks, valves, T's or other mechanical appurtenances 2 inches to 6 inches in diameter.
2002R
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of duct insulation.
2002S
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of radiator insulation and mastic.
2002T
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of plaster ceiling/wall.
2002U
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of drywall and/or drywall joint compound.
2002V
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of sprayed on or troweled on surfacing.
2002W
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of miscellaneous material.
2002X
| 1.00 |
| JB |
| ___________ |
Removal and disposal of asbestos containing fire-rated doors (does not require removal from frame).
2002Y
| 1.00 |
| JB |
| ___________ |
Encapsulation of remaining Asbestos Containing Material.
2002Z
| 1.00 |
| JB |
| ___________ |
Enclosure of remaining Asbestos Containing Material.
2002ZA
| 1.00 |
| JB |
| ___________ |
Mobilization/Demobilization fee for all Abatement Activities.
| 1.00 |
| JB |
| ___________ |
Emergency Call-In Service shall respond to that call within thirty (30) minutes and be onsite within two (2) hours ready to mobilize associated with any of the above services.
Rate multiplier for any of the above services to be performed off-hours or during the weekend.
GENERAL DEMOLITION ACTIVITIES ARE REQUIRED TO MEET INFECTION CONTROL RISK ASSESSMENT (ICRA) LEVEL 4 FOR WORK INSIDE OF THE HOSPITAL Contract Period: Option 3 POP Begin: 07-01-2028 POP End: 06-30-2029
3001A
| 1.00 |
| SF |
| ___________ |
Removal of existing flooring and associated adhesives (Subfloor to be free of all residue and ground to a flat, smooth finish)
3001B
| 1.00 |
| SF |
| ___________ |
Removal of partition metal stud and drywall with or without plaster skim coat and flattened expanded metal fastened to metal studs, including demountable partitions and repair damage to other wall surfaces. Remove all debris from Government property.
3001C
| 1.00 |
| SF |
| ___________ |
Removal of drywall with or without plaster skim coat on one side of partition or wall. Remove all debris from Government property.
3001D
| 1.00 |
| SF |
| ___________ |
Removal of wall protection, including but not limited to IPC rigid vinyl sheets and removal of all debris from Government property.
3001E
| 1.00 |
| SF |
| ___________ |
Removal of masonry style wall, including removal of all debris from Government property.
3001F
| 1.00 |
| SF |
| ___________ |
Removal of existing ceramic, porcelain, or quarry tile (wall and floor) and associated thinset/mortar
3001G
| 1.00 |
| SF |
| ___________ |
Removal of existing flooring and associated adhesives (Subfloor to be free of all residue and ground to a flat, smooth finish)
3001H
| 1.00 |
| SF |
| ___________ |
Remove wall covering, vinyl or fabric, including cleaning of the wall surface and remove from the Government property.
3001I
| 1.00 |
| JB |
| ___________ |
Remove door and frame from masonry type wall. Door and frame shall be removed from Government property unless requested to be returned to the Government.
3001J
| 1.00 |
| JB |
| ___________ |
Remove door and frame from drywall and/or demountable partition. Door and frame shall be removed from Government property unless requested to be returned to the Government.
3001K
| 1.00 |
| JB |
| ___________ |
Remove lockset from existing door and return to the Government.
3001L
| 1.00 |
| SF |
| ___________ |
Remove ceiling tile and suspension system, any type, and remove from the Government property.
3001M
| 1.00 |
| SF |
| ___________ |
Remove ceiling tile only and remove from the Government property.
3001N
| 1.00 |
| SF |
| ___________ |
Remove plaster style or solid ceiling, any type, and remove from Government property
3001O
| 1.00 |
| JB |
| ___________ |
Remove light fixture any type including exit, emergency light.
3001P
| 1.00 |
| JB |
| ___________ |
Remove electrical switch, any type. Remove electrical wall receptacle, any type including wiring up to 50'-0".
3001Q
| 1.00 |
| LF |
| ___________ |
Remove rigid style conduit, including installed feeders (not powered) up to 2 inches in diameter and remove from the Government property.
3001R
| 1.00 |
| LF |
| ___________ |
Remove rigid style conduit, including installed feeders (not powered) larger than 2 inches in diameter and remove from the Government property.
3001S
| 1.00 |
| JB |
| ___________ |
Remove electrical floor receptacle flush or pedestal and provide cap and plug assembly. Remove telephone floor outlet flush or pedestal and provide cap and plug assemble.
3001T
| 1.00 |
| JB |
| ___________ |
Remove electrical floor receptacle flush or pedestal and provide cap and plug assembly. Remove telephone floor outlet flush or pedestal and provide cap and plug assemble.
3001U
| 1.00 |
| JB |
| ___________ |
Removal of furniture, remove from Government property unless requested to be returned to the Government. Price shall be determined by the number of items.
3001V
| 1.00 |
| SF |
| ___________ |
Remove carpet tack-less method, glued down, or carpet tile including cleaning of the floor surface to remove residual glue and remove from the Government property.
3001W
| 1.00 |
| SF |
| ___________ |
Remove carpet pad any type and remove all debris from Government property, including cleaning of the floor surface.
3001X
| 1.00 |
| LF |
| ___________ |
Remove cove base molding or carpet base and remove from the Government property.
3001Y
| 1.00 |
| SF |
| ___________ |
Remove resilient floor tile, including cleaning of the floor surface and remove all debris from Government property.
3001Z
| 1.00 |
| JB |
| ___________ |
Removal of plumbing fixtures, including but not limited to toilets, sinks, urinals, restroom partitions, etc.
3001ZA
| 1.00 |
| LF |
| ___________ |
Removal of abandoned or isolated plumbing supply or return lines smaller than 2 inches in diameter.
3001ZB
| 1.00 |
| LF |
| ___________ |
Removal of abandoned or isolated plumbing supply or return lines greater than 2 inches in diameter.
3001ZC
| 1.00 |
| JB |
| ___________ |
Mobilization/Demobilization fee for all demolition activities.
ABATEMENT DEMOLITION ACTIVITIES ARE REQUIRED TO MEET INFECTION CONTROL RISK ASSESSMENT (ICRA) LEVEL 4 AND '12 NYCRR PART 56' FOR WORK INSIDE OF THE HOSPITAL
3002A
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of flooring and mastic (multiple layers will double the SF).
3002B
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of only flooring (multiple layers will double the SF).
3002C
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of only mastic (multiple layers will double the SF).
3002D
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of carpet.
3002E
| 1.00 |
| LF |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation up to 2 inches in diameter.
3002F
| 1.00 |
| LF |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation between 2 inches - 6 inches in diameter.
3002G
| 1.00 |
| LF |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation larger than 6 inches in diameter.
3002H
| 1.00 |
| JB |
| ___________ |
Glovebag removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of fittings, saddle blocks, valves, T's or other mechanical appurtenances 2 inches to 6 inches in diameter.
3002I
| 1.00 |
| SF |
| ___________ |
Removal and disposal of lead-based paint from Government property.
3002J
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements of Transite-type materials.
3002K
| 1.00 |
| LF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of Transite-type pipe up to 2 inches in diameter.
3002L
| 1.00 |
| LF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of Transite-type pipe between 2 inches - 6 inches in diameter.
3002M
| 1.00 |
| LF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of Transite-type pipe larger than 6 inches in diameter.
3002N
| 1.00 |
| LF |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation up to 2 inches in diameter.
3002O
| 1.00 |
| LF |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation between 2 inches - 6 inches in diameter.
3002P
| 1.00 |
| LF |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of pipe insulation larger than 6 inches in diameter.
3002Q
| 1.00 |
| JB |
| ___________ |
Removal (above glovebag limit), clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of fittings, saddle blocks, valves, T's or other mechanical appurtenances 2 inches to 6 inches in diameter.
3002R
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of duct insulation.
3002S
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of radiator insulation and mastic.
3002T
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of plaster ceiling/wall.
3002U
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of drywall and/or drywall joint compound.
3002V
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of sprayed on or troweled on surfacing.
3002W
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material and asbestos/waste related contaminated elements of miscellaneous material.
3002X
| 1.00 |
| JB |
| ___________ |
Removal and disposal of asbestos containing fire-rated doors (does not require removal from frame).
3002Y
| 1.00 |
| JB |
| ___________ |
Encapsulation of remaining Asbestos Containing Material.
3002Z
| 1.00 |
| JB |
| ___________ |
Enclosure of remaining Asbestos Containing Material.
3002ZA
| 1.00 |
| JB |
| ___________ |
Mobilization/Demobilization fee for all Abatement Activities.
| 1.00 |
| JB |
| ___________ |
Emergency Call-In Service shall respond to that call within thirty (30) minutes and be onsite within two (2) hours ready to mobilize associated with any of the above services.
Rate multiplier for any of the above services to be performed off-hours or during the weekend.
GENERAL DEMOLITION ACTIVITIES ARE REQUIRED TO MEET INFECTION CONTROL RISK ASSESSMENT (ICRA) LEVEL 4 FOR WORK INSIDE OF THE HOSPITAL
4001A
| 1.00 |
| SF |
| ___________ |
Removal of existing flooring and associated adhesives (Subfloor to be free of all residue and ground to a flat, smooth finish) Contract Period: Option 4 POP Begin: 07-01-2029 POP End: 06-30-2030
4001B
| 1.00 |
| SF |
| ___________ |
Removal of partition metal stud and drywall with or without plaster skim coat and flattened expanded metal fastened to metal studs, including demountable partitions and repair damage to other wall surfaces. Remove all debris from Government property.
4001C
| 1.00 |
| SF |
| ___________ |
Removal of drywall with or without plaster skim coat on one side of partition or wall. Remove all debris from Government property.
4001D
| 1.00 |
| SF |
| ___________ |
Removal of wall protection, including but not limited to IPC rigid vinyl sheets and removal of all debris from Government property.
4001E
| 1.00 |
| SF |
| ___________ |
Removal of masonry style wall, including removal of all debris from Government property.
4001F
| 1.00 |
| SF |
| ___________ |
Removal of existing ceramic, porcelain, or quarry tile (wall and floor) and associated thinset/mortar
4001G
| 1.00 |
| SF |
| ___________ |
Removal of existing flooring and associated adhesives (Subfloor to be free of all residue and ground to a flat, smooth finish)
4001H
| 1.00 |
| SF |
| ___________ |
Remove wall covering, vinyl or fabric, including cleaning of the wall surface and remove from the Government property.
4001I
| 1.00 |
| JB |
| ___________ |
Remove door and frame from masonry type wall. Door and frame shall be removed from Government property unless requested to be returned to the Government.
4001J
| 1.00 |
| JB |
| ___________ |
Remove door and frame from drywall and/or demountable partition. Door and frame shall be removed from Government property unless requested to be returned to the Government.
4001K
| 1.00 |
| JB |
| ___________ |
Remove lockset from existing door and return to the Government.
4001L
| 1.00 |
| SF |
| ___________ |
Remove ceiling tile and suspension system, any type, and remove from the Government property.
4001M
| 1.00 |
| SF |
| ___________ |
Remove ceiling tile only and remove from the Government property.
4001N
| 1.00 |
| SF |
| ___________ |
Remove plaster style or solid ceiling, any type, and remove from Government property
4001O
| 1.00 |
| JB |
| ___________ |
Remove light fixture any type including exit, emergency light.
4001P
| 1.00 |
| JB |
| ___________ |
Remove electrical switch, any type. Remove electrical wall receptacle, any type including wiring up to 50'-0".
4001Q
| 1.00 |
| LF |
| __________ |
Remove rigid style conduit, including installed feeders (not powered) up to 2 inches in diameter and remove from the Government property.
4001R
| 1.00 |
| LF |
| ___________ |
Remove rigid style conduit, including installed feeders (not powered) larger than 2 inches in diameter and remove from the Government property.
4001S
| 1.00 |
| JB |
| ___________ |
Remove electrical floor receptacle flush or pedestal and provide cap and plug assembly. Remove telephone floor outlet flush or pedestal and provide cap and plug assemble.
4001T
| 1.00 |
| JB |
| __________ |
Remove electrical floor receptacle flush or pedestal and provide cap and plug assembly. Remove telephone floor outlet flush or pedestal and provide cap and plug assemble.
4001U
| 1.00 |
| JB |
| ___________ |
Removal of furniture, remove from Government property unless requested to be returned to the Government. Price shall be determined by the number of items.
4001V
| 1.00 |
| SF |
| ___________ |
Remove carpet tack-less method, glued down, or carpet tile including cleaning of the floor surface to remove residual glue and remove from the Government property.
4001W
| 1.00 |
| SF |
| __________ |
Remove carpet pad any type and remove all debris from Government property, including cleaning of the floor surface.
4001X
| 1.00 |
| LF |
| ___________ |
Remove cove base molding or carpet base and remove from the Government property.
4001Y
| 1.00 |
| SF |
| ___________ |
Remove resilient floor tile, including cleaning of the floor surface and remove all debris from Government property.
4001Z
| 1.00 |
| JB |
| ___________ |
Removal of plumbing fixtures, including but not limited to toilets, sinks, urinals, restroom partitions, etc.
4001ZA
| 1.00 |
| LF |
| ___________ |
Removal of abandoned or isolated plumbing supply or return lines smaller than 2 inches in diameter.
4001ZB
| 1.00 |
| LF |
| ___________ |
Removal of abandoned or isolated plumbing supply or return lines greater than 2 inches in diameter.
4001ZC
| 1.00 |
| JB |
| ___________ |
Mobilization/Demobilization fee for all demolition activities.
ABATEMENT DEMOLITION ACTIVITIES ARE REQUIRED TO MEET INFECTION CONTROL RISK ASSESSMENT (ICRA) LEVEL 4 AND '12 NYCRR PART 56' FOR WORK INSIDE OF THE HOSPITAL
POP Begin: 06-01-2029 POP End: 05-31-2030
4002A
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of flooring and mastic (multiple layers will double the SF).
4002B
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of only flooring (multiple layers will double the SF).
4002C
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements or debris of only mastic (multiple layers will double the SF).
4002D
| 1.00 |
| SF |
| ___________ |
Removal, clean-up and disposal of asbestos containing material (ACM) and asbestos/waste related contaminated elements…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .