36C24224Q0254_1.docx
DOCX document 23 KB Posted
- Attached to
- 6520--Brand Name or Equal DentalEZ / Nevins Lab Workstations with Suction and Electric Handpieces
- Solicitation number
- 36C24224Q0254
About this file
This is a combined synopsis/solicitation notice for brand name or equal dental laboratory workstations with suction and electric handpieces. The Department of Veterans Affairs, on behalf of the VA New Jersey Healthcare System, is seeking quotes for two-sided, face-to-face pedestal workstations between 44 to 48 inches in length and 55 to 60 inches deep. Each workstation must include overhead task lighting, a dust extraction system, knee-activated electric handpieces, a minimum of four drawers per side, and electrical outlets. Quotes are due no later than January 22, 2024 at 12:00 PM Eastern Time and will be evaluated based on price, technical compliance, and delivery/installation schedule. This requirement is set aside for small businesses.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24224Q0254.docx | DOCX document | |
| D0904 Dental Lab Workstation wSuction and Electric Handpieces SOW.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUBJECT*
Brand Name or Equal DentalEZ / Nevins Lab Workstations with Suction and Electric Handpieces
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 12208-3410 |
| SOLICITATION NUMBER* |
| 36C24224Q0254 |
| RESPONSE DATE/TIME/ZONE |
| 01-22-2024 12:00 PM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 5 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SBA |
| PRODUCT SERVICE CODE* |
| 6520 |
| NAICS CODE* |
| 339114 |
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs Network Contracting Office NCO2 20 Madison Avenue Extension Albany NY 12203
POINT OF CONTACT*
Contracting Officer Lindsay Goldsmith Lindsay.Goldsmith@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
VA New Jersey Healthcare System
Toms River VA Outpatient Clinic
1055 Hooper Ave
Toms River New Jersey
| POSTAL CODE |
| 08753-8322 |
COUNTRY
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice
DESCRIPTION
| *= Required Field |
| Combined Synopsis/Solicitation Notice |
Combined Synopsis/Solicitation Notice
The Department of Veterans Affairs on behalf of the VA New Jersey Healthcare System in Toms River NJ, has a BRAND NAME OR EQUAL requirement for Surgical Dental Drill Systems as defined below.
This requirement is set aside for small businesses (SB).
All small business (SB) vendors meeting the standard of an acceptable source under the terms of either a manufacturer or authorized distributor are encouraged to provide a bid.
All vendors are required to be registered with the System for Award Management (sam.gov) and deemed in good standing and available for award. All bids shall include the vendors unique entity identifier number provided by sam.gov.
All vendors claiming authorized distributor status must provide a letter from the manufacturer.
Quotes shall be Firm Fixed Price (FFP); evaluations will be based on Best Value Criteria, in accordance with FAR 52.212-2, and utilizing the evaluation factors of price, technical compliance and delivery / installation schedule (see clauses below).
Items listed in this requirement;
| CLIN |
| Sub Line |
| Item Description |
Basis of Design for BRAND NAME OR EQUAL
| Part # (Basis of Design ONLY) |
| Quantity |
Dental EZ / Nevin Labs Pedestal Workstation
Two Person, Face to Face Pedestal Workstation with dust collector and 2 electric handpieces.
| See Sub Lines. |
| 1 |
| 1-1 |
| 3 Way 20 Amp 277V Whist Switch |
| 10120SWW |
| 2 |
| 1-2 |
| Double Duplex 20Amp Receipt |
| 10220 |
| 2 |
| 1-3 |
| 20A DUP Dbl Duplex + 2 USB, Box, Chrome Cover |
| 10220DUPWUSB |
| 2 |
| 1-4 |
| Retractable Air Gun System |
| 2001AG |
| 2 |
| 1-5 |
| 206gas Valve with 212 Flange |
| 206G212 |
| 2 |
| 1-6 |
| Bracket for Air Gun (nozzle) |
| 209B |
| 2 |
| 1-7 |
| Blast Gate w/3-1/2 in Duct |
| 322 |
| 2 |
| 1-8 |
| Moulded Plastic Grinding Hood |
| 325 |
| 2 |
| 1-9 |
| 42” X 24” X 3” Frame, No Top |
| 33042NT |
| 3 |
| 1-10 |
| Under Frame Support |
| 333 |
| 2 |
| 1-11 |
| 3-1/2in dia. Flex Hose – {by foot} |
| 351FH |
| 6 |
| 1-12 |
| 3-1/2in Hose Clamps |
| 351HC |
| 4 |
| 1-13 |
| Dust Collector for use W/3-1/2 |
| 444R |
| 1 |
| 1-14 |
| Staron ½” Sanded (Vermillion or Gray) Finished sqft |
| 475FINCOR |
| 26 |
| 1-15 |
| 30 5/8” Ht X 60” DP Panel Leg |
| 60SPL |
| 2 |
| 1-16 |
| 35 Watt LED Light with 40” Shelves, 14.25” Support Tubes |
| 800110-LED |
| 2 |
| 1-17 |
| 4 Drawer Cab. For Power Frames |
| 9200CAB |
| 2 |
| 1-18 |
| Mount Panel for Knee Control |
| DC91110 |
| 2 |
| 1-19 |
| 6” X 8” Filler Panel |
| DF4168 |
| 2 |
| 1-20 |
| 1 ½” Dia Hole w/ Snap Ring |
| HOLE1.5 |
| 2 |
| 1-21 |
| VARIOstar K50 Knee Control Unit 120V |
| K50 |
| 2 |
| 1-22 |
| Double Side, Metal Backshelf |
| MBS2 |
| 4 |
Description: Brand name or equal modular technician's workstation for the dental laboratory. The unit contains an overhead task lighting array. The workstation also includes a dust extraction system with filtration, knee activated electric handpieces, a minimum of 4 drawers for storage, per side, and electrical outlets for accessory equipment. The workstation generally has slanted overhead case pan shelves for storing equipment trays. The desktop is made from a fiber/cement mixture or similar material to resist heat, abrasion, and chemical attack. The workstation shall have the following Salient Characteristics:
· Shall be two-sided, face to face, pedestal design
· Shall be between 44” to 48” in length
· Shall be between 55” to 60” deep (entire face to face pedestal workstation)
· Shall have a work surface depth of 20” to 24”
· Shall have an ADA seating opening of approximately 32” high
· Shall have at least four drawers, per user
· Shall have at least a 35-watt task side, and two slanted overhead case pan shelves per user
· Task light and shelves shall be at least 40” in length and not extend past the outer dimension of the workstation
· Shall have at least two sets of double duplex outlets per user
· Shall have an integrated dust collector
· capable of collecting 0.5 microns
· capable of at least 750 CFM
· blast gates will be approximately 3.5” in diameter and mounted to the rear of the work surface, one per user
· Workstation shall be in Postal Blue color or similar
· Shall have a solid surface countertop in Sanded Grey color or similar
· Shall be 120VAC, 60Hz, 20Amp with hospital grade plug
· Shall have a brushless handpiece with knee control, one per user
· capable of being operated with left or right hand rotation
· up to 50,000 rpm
· capable of sending start-up signal to dust collector
· Shall be 115VAC, 60Hz, with hospital grade plug
This procurement is limited to new equipment only. Used, gray, refurbished or aftermarket equipment will not be considered for this requirement. The Veterans Health Administration prohibits the use of gray/ aftermarket items in their Medical Centers. Gray/ aftermarket items are considered to be items outside of the original equipment manufacturer's intended distribution channels. Quotes for other than new, will be deemed non-compliant and will be removed from the competitive range without discussion.
Delivery shall be quoted Free on Board (FOB) to the Department of Veterans Affairs, VA New Jersey Healthcare System, Toms River VA Outpatient Clinic, 1055 Hooper Avenue Toms River, NJ 08753.
CLAUSES
ADDENDUM to 52.212-2 EVALUATION—COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES
(a) Basis for Award. The Government will issue a purchase order to the responsible quoter whose quotation conforming to the solicitation will be most advantageous to the Government, price and other factors considered.
(b) The following factors shall be used to evaluate quotations:
1. Price
2. Technical Compliance with the SOW.
3. Delivery and Installation Schedule
(c) Evaluation Approach. The Government will evaluate quotations using the comparative evaluation process outlined in FAR 13.106-2 (b) (3), where quotations will be compared to one another to determine which provides the best benefit to the Government. The Government reserves the right to consider a quotation other than the lowest price that provides additional benefit(s). Quotations may exceed minimum requirements of the solicitation. The Government reserves the right to select a quotation that provides benefit to the Government that exceeds the minimum requirements of the solicitation but is not required to do so. Each response must meet the minimum requirements of the solicitation. The Government is not requesting or accepting alternate quotations. The evaluation will consider the following:
(1) Price: The Government will evaluate the price by adding the total of all line-item prices. The Total Evaluated Price will be that sum.
(2) Technical Compliance: The proposed units compliance with the salient characteristics and the SOW.
(3) Delivery and installation schedule: The Government will evaluate the schedule by total days proposed for completed installed job.
CLAUSES INCORPORATED BY REFERENCE:
FAR 52.212-1 Instructions to Offerors—Commercial Products and Commercial Services.
FAR 52.212-3 Offeror Representations and Certifications—Comm Products and Comm Services.
FAR 52.212-4 Contract Terms and Conditions—Commercial Products and Commercial Services FAR 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders—Commercial Products and Commercial Services.
Responses to this notice must be submitted in writing via email to lindsay.goldsmith@va.gov and must be received not later than Monday, January 22, 2024, at 12:00 PM. No telephone inquiries will be accepted. Late submissions shall be treated in accordance with the solicitation provision FAR 52.212-1(f).
See attached document: D0904 Dental Lab Workstation wSuction and Electric Handpieces SOW.
See attached document: 36C24224Q0254.
Page 1 of
File details come from the government source that posted it. Updated .