36C24220R0045-005.pdf
PDF Posted
- Solicitation number
- 36C24220R0045
About this file
36C24220R0045 Exhibit 4 Nurses Station Units 21 22 Rev 1 as of 12-27-19.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24220R0045-0001000.docx | DOCX document | |
| 36C24220R0045-006.docx | DOCX document | |
| 36C24220R0045-002.xlsx | XLSX spreadsheet | |
| 36C24220R0045-003.pdf | ||
| 36C24220R0045-004.pdf | ||
| 36C24220R0045-007.docx | DOCX document | |
| 36C24220R0045-001.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
13'-11"
11 1/2"
2'-8 1/2"
3'-8 1/2"
/2
3'-1"
Remove existing wood frame and post.
Install a 1" single metal tubular partition frame to fit a 5/16 laminated safety glass.
Color of frame TBD upon approval.
Existing metal frame to remain. Repaint frame to match existing paint color.
1" 3'-1" 1"
Department of Veteran Affairs Northport VA - Building 200, Units 21 & 22 – Exhibit 4A
1"1"
Front Elevation1
Scale: ½”=1'0"2
*All submittals to be submitted for approval not later then 10 days after NTP
NOTE: Add tamper proof screws to existing window frame retaining bars. Caulk as required. Reinstall retaining bars with new tampered proof screws
Adhesive alone is unacceptable.
Corner and side frame to have rounded edge surface or rubber guard.
Existing nursing station and counter height to remain.
1'-11"
/2
Department of Veteran Affairs Northport VA - Building 200, Units 21 & 22 – Exhibit 4B
1'-6"
Side Elevation2 2 Scale: ½”=1'0"
*All submittals to be submitted for approval not later then 10 days after NTP
Existing metal frame to remain. Repaint frame to match existing paint color.
Corner and side frame to have rounded surface or rubber guard.
NOTE: Add tamper proof screws to existing window frame retaining bars. Caulk as required. Reinstall retaining bars with new tampered proof screws Adhesive alone is unacceptable.
Remove existing wood frame and post.
Install a 1" single metal tubular partition frame to fit a 5/16 laminated safety glass.
Color of frame TBD upon approval.
Contractor to provide color samples.
Department of Veteran Affairs Northport VA - Building 200, Units 21 & 22 – Exhibit 4C
Existing condition in Unit 21. Existing condition in Unit 22.
*All submittals to be submitted for approval not later then 10 days after NTP
| 2019_1227 Department of VA_Nurses Station_Unit21+22_Elevations.vsd |
| Page-1 |
| Page-2 |
| Page-3 |