S05 REGULATED BUILDING MATERIALS SURVEY REPORT.pdf
PDF 6 MB Posted
- Solicitation number
- 36C24220B0062
About this file
This document outlines a federal contract opportunity for corrective facility condition deficiency work at the VA East Orange Campus in New Jersey. The solicitation seeks bids for mechanical, electrical, plumbing, and structural repairs to Building 8's boiler plant, with an estimated cost between $1-2 million. Responses are due by the date specified in solicitation number 36C24220B0062, to be posted on October 15, 2020. The work includes temporary systems, pipe replacements, equipment demolitions and installations, electrical upgrades, and proprietary boiler and control systems to be provided by Miller & Chitty Company. The contract has a 180-day completion period and is set aside for Service-Disabled Veteran Owned Small Businesses. The Department of Veterans Affairs Veterans Health Administration VISN 2 is the contracting agency.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24220B0062 0003.docx | DOCX document | |
| S05 RFIs-36C24220B0062 Responses.pdf | ||
| 36C24220B0062 0002.docx | DOCX document | |
| 36C24220B0062 0001.docx | DOCX document | |
| 36C24220B0062_1.docx | DOCX document | |
| S02 Wage Determination.pdf | ||
| S02 _SINGLE SPEC Boiler FCA_rev1.pdf | ||
| S02 Correct Boiler FCA Deficiencies Drawings - Issued for Bid.pdf | ||
| P03 Brand Name PM_Part806.3_Atch2_FAR6_JA_OVER_SAT.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
p
REGULATED BUILDING MATERIALS
SURVEY REPORT
East Orange VA Medical Center Building 8 Boiler House
A/E Design Services, Correct FCA Deficiencies VA Project No. 561-18-180 385 Tremont Ave.
East Orange, NJ
May 15, 2020 Mabbett Project No. R2019057.002.001
Prepared for:
Miller-Remick, LLC.
1010 Kings Highway South Cherry Hill, NJ 08034
Mabbett & Associates, Inc.
105 Central Street, Suite 4100 Stoneham, MA 02180-1260 T. 781-275-6050 Massachusetts | Virginia | Rhode Island | New Jersey
© 2020, Mabbett & Associates, Inc.
www.mabbett.com
REGULATED BUILDING MATERIALS SURVEY REPORT
VAMC A/E Design Services, Bldg. 8 Correct FCA Deficiencies| East Orange, N.J.
© 2020, Mabbett & Associates, Inc. Page i May 15, 2020 Project No. R2019057.002.001 S:\ADMINA\2019057 Miller-Remick\002\001\Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc
ACKNOWLEDGEMENT
This Regulated Building Materials Survey Report has been prepared by Mabbett & Associates, Inc. (Mabbett®) for the A/E Design Services to Correct FCA Deficiencies, Building 8 at the East Orange Veterans Affairs Medical Center located in East Orange, New Jersey, VA Project No. 561-18-180. The information presented herein is based on the facts and information conveyed to or received by Mabbett during the preparation of this report. If any of the information provided to Mabbett that was used in preparing this report is incorrect, incomplete, or subject to change, Mabbett would wish to alter its opinion(s) accordingly. In addition, the professional opinions and information contained in this report are based solely on the requirements of the applicable regulations and technical data as known to Mabbett as of the date of this report and considered applicable to this report.
The attached Regulated Building Materials Survey Report was prepared by the following Mabbett personnel:
Kevin M. Donovan Environmental, Health & Safety Specialist
This report has been reviewed and approved by:
Michael F. Delaney Director, Building Sciences Group
© 2020, Mabbett & Associates, Inc. Page ii May 15, 2020 Project No. R2019057.002.001 S:\ADMINA\2019057 Miller-Remick\002\001\Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc
TABLE OF CONTENTS
SECTION PAGE
1.0 INTRODUCTION
2.0 ASBESTOS SURVEY
2.1 Sampling Methodology
2.2 Analytical Methodology
2.3 Summary of Asbestos Containing Materials Findings
3.0 LEAD CONTAINING PAINT SURVEY
4.0 CONCLUSIONS AND RECOMMENDATIONS
4.1 Asbestos
4.2 Lead Containing Paint
5.0 LIMITATIONS
TABLES
Table 1 – Summary of ACM (in text) Table 2 – Summary of Lead Paint Chip Analytical Results (in text)
FIGURES
ASB-1 Ground Floor, Asbestos and Lead Sampling Location Plan ASB-2 Roof, Asbestos and Lead Sampling Location Plan
APPENDICES
Appendix A – Summary of ACM Building Survey Results, Including Negative Results Appendix B – PLM Laboratory Report and Chain of Custody Appendix C – Lead Paint Chip Laboratory Report and Chain of Custody
© 2020, Mabbett & Associates, Inc. Page 1 May 15, 2020 Project No. R2019057.002.001 S:\ADMINA\2019057 Miller-Remick\002\001\Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc
1.0 INTRODUCTION
Mabbett and Associates, Inc. (Mabbett®) performed a survey for regulated building materials (RBM) as part of the A/E Design to Correct FCA Deficiencies, Building 8 at the East Orange Veterans Affairs Medical Center (VAMC) located in East Orange, New Jersey, VA Project No. 561-18-180. Site survey work was performed on April 30, 2020 by appropriately credentialed regulated building materials inspectors, and consisted of the following activities:
A review of the existing 95% A/E Construction Documents;
An Asbestos Containing Material (ACM) survey of suspect materials (Analysis by Polarized Light Microscopy
[PLM] and Transmission Electron Microscopy [TEM]); and Limited Lead Containing Paint (LCP) sampling (Analysis by atomic absorption [AA]).
The survey was limited to Building 8, Boiler House and areas anticipated to be disturbed and identified on the 95% construction set drawings, dated April 10, 2020 which was provided to Mabbett prior to the survey. Areas and materials outside of this scope of work were not surveyed by Mabbett.
2.0 ASBESTOS SURVEY
A visual screening inspection was conducted by EPA trained and accredited asbestos inspectors to identify locations of suspect ACM and conceptualize the sampling program. Only areas that were accessible during the field work phase were inspected, with reasonable efforts made during the initial field survey work to access areas as necessary to complete the asbestos survey and sampling program.
Prior to the execution of this survey, provided Building 8 plans were examined and VA engineering personnel interviewed to discern the age and condition of existing materials, as well as the renovation history of the areas being surveyed.
2.1 Sampling Methodology
Site inspection work was performed on April 30, 2020, by EPA trained and accredited asbestos inspector Mr. Kevin Donovan. Bulk asbestos samples were collected using EPA National Emissions Standards for Hazardous Air Pollutants (NESHAP), 40 CFR Part 763, and Asbestos Hazard Emergency Response Act (AHERA) protocols. The inspection was limited to areas that may be impacted by the proposed renovation project. Bulk suspect ACM sampling was generally conducted according to the following sampling protocol:
Friable surfacing material:
At least three bulk samples shall be collected from each homogeneous area that is 1,000 ft2 or less.
At least five bulk samples shall be collected from each homogeneous area that is greater than 1,000 ft2 but less than or equal to 5,000 ft2.
At least seven bulk samples shall be collected from each homogeneous area that is greater than
5,000 ft2.
Thermal system insulation:
At least three bulk samples shall be collected from each homogeneous area of thermal system insulation.
At least one bulk sample shall be collected from each homogeneous area of patched area of thermal system insulation.
Sufficient samples shall be collected from elbows and fittings to determine if they contain ACM.
Bulk samples shall not be collected from any homogeneous area where the state licensed asbestos inspector determined that the thermal system insulation is fiberglass, foam glass, rubber, or other non-ACM.
© 2020, Mabbett & Associates, Inc. Page 2 May 15, 2020 Project No. R2019057.002.001 S:\ADMINA\2019057 Miller-Remick\002\001\Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc
Miscellaneous material:
At least two bulk sample shall be collected from each homogeneous area that is less than 100 ft2.
At least three bulk samples shall be collected from each homogeneous area that is greater than 100 ft2.
Areas that were inaccessible, or where the survey was limited to visual observation only, are identified below:
Within walls Within fire doors Enclosed pipe/duct chases Inside mechanical equipment/ductwork Above fixed drywall or plaster ceilings Electrical equipment
2.2 Analytical Methodology
The collected bulk samples were submitted under chain of custody (COC) procedures to AmeriSci of Midlothian, VA for polarized light microscopy (PLM) analysis of bulk materials using EPA Methods 600/R-93/116. AmeriSci is accredited by the American Industrial Hygiene Association (AIHA) and participates in the National Voluntary Laboratory Accreditation Program (NVLAP) and is licensed by the New Jersey Department of Environmental Protection (NJDEP) (Certification No. VA012) for asbestos analysis.
All bulk sample results from this inspection are summarized in Appendix A, Summary of ACM Building Survey Results.
The EPA, Occupational Safety and Health Administration (OSHA), and the NJDEP defines any material that contains greater than one percent (>1%) asbestos as being an ACM. As such, the analytical laboratory identified bulk samples as positive for asbestos that met the regulatory criteria of greater than one percent (>1%) asbestos. Laboratory reports and COC documentation are provided in Appendix B of this report.
2.3 Summary of Asbestos Containing Materials Findings
Mabbett identified sixteen (16) areas of homogenous materials and collected fifty-one (51) representative bulk ACM samples. Asbestos sampling locations and results are identified on Figures ASB-1 and ASB-2. The laboratory reported analytical data indicated that there (3) homogenous materials had greater than 1% asbestos and were identified as ACM. Estimated quantities of materials identified as ACM are presented in Table 1 below:
TABLE 1
Summary of ACM
A/E Design Services to Correct FCA Deficiencies, Building 8 East Orange Veterans Affairs Medical Center
Location Description of Material Percent and Type of Asbestos
Estimated Quantity Amount Units
Exterior, East Side of Building White Door Frame Caulk 3% Chrysotile 25 Linear Feet
Roof, Penthouse Siding Yellow Stucco (Joint Compound Layer) 2% Chrysotile 400 Square Feet
Roof, Penthouse Gray Door Frame Caulk 3% Chrysotile 20 Linear Feet
© 2020, Mabbett & Associates, Inc. Page 3 May 15, 2020 Project No. R2019057.002.001 S:\ADMINA\2019057 Miller-Remick\002\001\Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc
3.0 LEAD CONTAINING PAINT SURVEY
The limited LCP survey included the collection of paint chips from painted surfaces and systems in Building 8 that may be impacted by the planned renovation. Ten (10) samples of different homogenous areas of paint were collected during this survey. Paint chip samples were submitted under standard COC procedures to Environmental Hazards Services, LLC (EHS), via AmeriSci. Analysis was conducted using EPA Method SW846 7000B: Flame Atomic Absorption Spectrophotometry.
The results of the limited LCP sampling are summarized in Table 2, with laboratory reports provided in Appendix C.
TABLE 2
Summary of Lead Paint Chip Analytical Results
A/E Design Services to Correct FCA Deficiencies, Building 8 East Orange Veterans Affairs Medical Center
Sample # Location Substrate and Component Color Result
(% Pb by Wt.)
Pb-01 Overhead Door Concrete Floor Gray 0.0087 Pb-02 Between Boilers 1 and 2 Metal Stair Frame Green 19 Pb-03 Mezzanine Concrete Deck Gray 0.06 Pb-04 Mezzanine Concrete Beam Gray 0.063 Pb-05 Mezzanine Metal Stairs White 2.1 Pb-06 Mezzanine Metal Railing Green <0.0097 Pb-07 Boiler House Metal Door Frame White 0.097 Pb-08 Boilers 2 and 3 Metal Drain Pipe Silver 0.42 Pb-09 Roof Access Metal Door Gray 30 Pb-10 Roof Vent Rubber Vent Base Silver <0.0050
The Occupational Safety & Health Administration (OSHA) does not recognize a “safe” level of lead in paint.
Depending on the method of removal used, even trace amounts of lead in paint may result in airborne concentrations of lead during removal. An employer or contractor who disturbs or removes lead paint must comply with OSHA Standard 29 CFR 1926.62, “Lead Exposure in Construction; Interim Final Rule.”
4.0 CONCLUSIONS AND RECOMMENDATIONS
4.1 Asbestos
Identified ACM must be abated and properly disposed of prior to disturbance by state licensed and properly trained contractors. All abatement must be performed in accordance with federal, state and local requirements. Any suspect materials encountered during demolition or renovation activities that were not identified in this report as being non- ACM, should be assumed to be ACM unless sample results prove otherwise. Suspect ACM that may be present within operating equipment, walls, above inaccessible hard ceilings, or in other inaccessible locations, should be assumed to contain asbestos if discovered during any demolition or renovation process or until otherwise verified.
4.2 Lead Containing Paint
The purpose of the limited LCP survey was to identify similar areas of LCP. During the on-site survey, representative samples of similar areas of interior and exterior building coatings were collected and analyzed for lead content. The regulations addressing LCP in non-residential buildings are focused on occupational exposures involved with paint-disturbing activities and related waste-disposal activities.
© 2020, Mabbett & Associates, Inc. Page 4 May 15, 2020 Project No. R2019057.002.001 S:\ADMINA\2019057 Miller-Remick\002\001\Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc
Occupational exposure to lead during construction is regulated by OSHA regulation 29 CFR 1926.62 “Lead in Construction,” as well as other applicable state and local regulations. These regulations involve air monitoring to determine worker exposure levels when disturbing paint containing measurable levels of lead. This LCP survey cannot determine a safe level of lead for the purpose of paint-disturbing activities. However, this report is intended to provide guidance as to the location of LCP so it can be controlled, abated or disposed of properly during this project’s construction related activities. Information gathered during this LCP survey should be used to determine where worker exposures to airborne lead may occur. Additionally, this information should also be used to assess the potential for exposure to workers, and for determining appropriate controls necessary to limit his or her health risks during this project.
A concentration of lead greater than or equal to 0.5 percent by weight or 1.0 mg/cm2 exceeds EPA and HUD residential standards and is considered an indicator of risk. Representative samples of LCP waste to be generated during building renovation, or following demolition but prior to disposal, should be collected and analyzed using toxicity characteristic leaching procedure (TCLP) in accordance with 40 CFR Part 261. Management and disposal of lead containing waste must be done in accordance with all applicable local, state, and federal regulations.
OSHA regulations may require certain procedures for any paint that contains lead, even if it is below these levels. All LCP identified, regardless of the lead content, should either be sampled and analyzed by TCLP and then handled/disposed of accordingly, or segregated from other large-scale debris and then managed as hazardous waste in accordance with federal, state and local hazardous waste disposal regulations.
5.0 LIMITATIONS
This survey report is the result of a diligent and thorough inspection for regulated building materials of the designated areas and materials that may be impacted by the renovation project. Inaccessible areas were not included in this survey. Although a comprehensive inspection of these areas was performed, Mabbett does not claim to have identified all hazardous materials that could be present in the facility (for example, materials potentially located within the inaccessible areas). Mabbett has conducted this assessment with reasonable care and has performed this project in accordance with generally accepted industry standards. There can be no assurances, and Mabbett makes no assurances, that the information, research, and technology used to prepare this report may not change in the future, thus affecting the results reported herein.
© 2020, Mabbett & Associates, Inc. FIGURES May 15, 2020 Project No. R2019057.002.001 Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc
FIGURES
NO. DESCRIPTION DATE
o n e e i g h t h i n c e f o t
B
A
C
D
E
F t h r e e i n c h e s o t o n e a d a l f i n c h e o t o n e i n o t t h r e e q u a r t e r s i n o t o n e h a l f i n o t t h r e e e i g h t h s i n o t o n e q u a r t e r i n o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned
Small Business
A
S r v i c e
D i s a b l
V t e r a
O w n m a l
B u s i n e s s
SDVOSB
CVE
MR PROJECT NO: 0499-0122
B
A
C
D
E
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANT CORRECT FCA DEFICIENCIES
VA EAST ORANGE CAMPUS
561-18-180
BUILDING 8
Project Director
2020-04-15
95% CONSTRUCTION
DOCUMENTS
NOT FOR CONSTRUCTION
ASBESTOS & LEAD SURVEY PLAN
BUILDING-8
GROUND FLOOR
MFD DJA
ASB-1
Scientists I Engineers I Program Managers
Mabbett & Associates, Inc.
105 Central Street Stoneham, MA 02180
T. 781-275-6050 www.mabbett.com
Mabbett
R
PLAN
NORTH
ACTUAL
NORTH
KEYPLAN
05A*
05A**
05A
05A
06A*
Pb-01
04B, 04C
04A
10A
10B, 10C
05A, 05B
05C Pb-07
07A, 08A, 08B, 08C
07B 07C
Pb-01
09A 09B 09C
02B
03C
02C 03B
06B**, 06C**
03A
02A
Pb-06Pb-08Pb-02Pb-03Pb-04Pb-05
01C01A, 01B
SECOND FLOOR LOCKER ROOM
SAMPLES,
02A, 02B, 02C
03A, 03B, 03C
AutoCAD SHX Text
STAIRS
AutoCAD SHX Text
STAIRS
AutoCAD SHX Text
BOILER
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
EMERGENCY
AutoCAD SHX Text
GENERATOR
AutoCAD SHX Text 8-02
AutoCAD SHX Text
CONDENSATE
AutoCAD SHX Text
PUMP
AutoCAD SHX Text
ROOM
AutoCAD SHX Text 8-03A
AutoCAD SHX Text
STAIRWAY
AutoCAD SHX Text
MAIN
AutoCAD SHX Text 8-04
AutoCAD SHX Text 8-01
AutoCAD SHX Text 8-03
AutoCAD SHX Text 8-B1
AutoCAD SHX Text 8-B2
AutoCAD SHX Text 8-B3
AutoCAD SHX Text 8-B4
AutoCAD SHX Text
(EX)
AutoCAD SHX Text
(EX)
AutoCAD SHX Text
EX.BLOW-OFF TANK
AutoCAD SHX Text
(EXISTING)
AutoCAD SHX Text
600HP BOILER
AutoCAD SHX Text
(EXISTING)
AutoCAD SHX Text
600HP BOILER
AutoCAD SHX Text
(EXISTING)
AutoCAD SHX Text
600HP BOILER
AutoCAD SHX Text
(EXISTING)
AutoCAD SHX Text
600HP BOILER
AutoCAD SHX Text
(EXISTING)
AutoCAD SHX Text
CONTROL ROOM
AutoCAD SHX Text
BOILER MASTER
AutoCAD SHX Text
CONTROL PANEL
AutoCAD SHX Text
MCC
AutoCAD SHX Text
(E) FIRE HYDRANT
AutoCAD SHX Text
(E) TRANSFORMER
AutoCAD SHX Text
(E) PROPANE STORAGE
AutoCAD SHX Text
(E) CONDENSING UNIT
AutoCAD SHX Text
(E) CONDENSING UNIT
AutoCAD SHX Text
(E) UNDERGROUND FUEL TANKS
AutoCAD SHX Text
(E) GENERATOR FUEL TANK
AutoCAD SHX Text
(E) ELECTRICAL PANELS
AutoCAD SHX Text
(E) FD
AutoCAD SHX Text
(E) PUMP
AutoCAD SHX Text
(E) PUMP
AutoCAD SHX Text
(E) FD
AutoCAD SHX Text
(E) SURGE TANK
AutoCAD SHX Text
(E) FD
AutoCAD SHX Text
(E) FD
AutoCAD SHX Text
(E) FD
AutoCAD SHX Text
(E)FD
AutoCAD SHX Text
(E) PUMPS
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
AutoCAD SHX Text
ASBESTOS & LEAD SURVEY PLAN - GROUND FLOOR
AutoCAD SHX Text 3/16" = 1'-0"
AutoCAD SHX Text
STOP POSITIVE SAMPLE FOR ASBESTOS
AutoCAD SHX Text
NO ASBESTOS DETECTED (NAD)
AutoCAD SHX Text
SAMPLE POSITIVE FOR ASBESTOS
AutoCAD SHX Text
APPROXIMATE SAMPLE LOCATION
AutoCAD SHX Text
GENERAL SHEET NOTES:
AutoCAD SHX Text LEAD (Pb) SAMPLING LOCATION
NO. DESCRIPTION DATE
n e e i g h t i o t
B
A
C
D
E
F t h r e e i n c h e o t o n e a a l f i n c h e o t o n e i n o t t h r e e q u a r t e r s i n o t o n e h a l f i n o t t h r e e e i g h t h s i n o t o n e q u a r t e r i n o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned
Small Business
A r v i c e
D i s a b l
V t e r a
O w n m a
B u s i n e s s
SDVOSB
CVE
MR PROJECT NO: 0499-0122
B
A
C
D
E
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseENGINEER OF RECORDCONSULTANT CORRECT FCA DEFICIENCIES
VA EAST ORANGE CAMPUS
561-18-180
BUILDING 8
Project Director
2020-04-15
95% CONSTRUCTION
DOCUMENTS
NOT FOR CONSTRUCTION
ASBESTOS AND LEAD SURVEY PLAN
BUILDING-8
ROOF
MFD DJA
ASB-2
Scientists I Engineers I Program Managers
Mabbett & Associates, Inc.
105 Central Street Stoneham, MA 02180
T. 781-275-6050 www.mabbett.com
Mabbett
R
PLAN
NORTH
ACTUAL
NORTH
KEYPLAN
05A*
05A**
05A
05A
Pb-01
12A*, 12B**, 13A
11A.1, 11A.2*
Pb-09
16A 16B 16C
11C.1, 11C.2** 12C**, 13B, 13C
14A
15C
Pb-10
15A 15B 14C
14B
11B.1, 11B.2**
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text (E)
AutoCAD SHX Text
RELIEF VENTS
AutoCAD SHX Text (E)
AutoCAD SHX Text
RELIEF VENTS
AutoCAD SHX Text (E)
AutoCAD SHX Text
RELIEF VENTS
AutoCAD SHX Text (E)
AutoCAD SHX Text
RELIEF VENTS
AutoCAD SHX Text (E)
AutoCAD SHX Text
BOILER STACK
AutoCAD SHX Text (E)
AutoCAD SHX Text
BOILER STACK
AutoCAD SHX Text (E)
AutoCAD SHX Text
BOILER STACK
AutoCAD SHX Text (E)
AutoCAD SHX Text
BOILER STACK
AutoCAD SHX Text (E)
AutoCAD SHX Text
RELIEF VENT
AutoCAD SHX Text
(E)EXISTING MAKE-UP AIR HEATER HV-1
AutoCAD SHX Text
(E)EXISTING MAKE-UP AIR HEATER HV-2
AutoCAD SHX Text (E)
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text (E)
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text (E)
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text (E)
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
AutoCAD SHX Text
ASBESTOS AND LEAD SURVEY PLAN - ROOF PLAN
AutoCAD SHX Text 3/16" = 1'-0"
AutoCAD SHX Text
STOP POSITIVE SAMPLE FOR ASBESTOS
AutoCAD SHX Text
NO ASBESTOS DETECTED (NAD)
AutoCAD SHX Text
SAMPLE POSITIVE FOR ASBESTOS
AutoCAD SHX Text
APPROXIMATE SAMPLE LOCATION
AutoCAD SHX Text
GENERAL SHEET NOTES:
AutoCAD SHX Text LEAD (Pb) SAMPLING LOCATION
© 2020, Mabbett & Associates, Inc. APPENDIX A May 15, 2020 Project No. R2019057.002.001 Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc
APPENDIX A
Summary of ACM Building Survey Results, Including Negative Results
© 2020, Mabbett & Associates, Inc. Appendix A Page 1 of 2 May 15, 2020 Project No. R2019057.002.001 Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc
APPENDIX A
Summary of ACM Sampling Results A/E Design Services to Correct FCA Deficiencies, Building 8
East Orange Veterans Affairs Medical Center
Sample No. Sample Location Description of Material
Percent and Type of
Asbestos
01A Boiler 2 White Fiberglass End Sealant NAD
01B Boiler 2 White Fiberglass End Sealant NAD
01C Boiler 3 White Fiberglass End Sealant NAD
02A 2nd Floor Locker Room Blow-Off Tank Insulation NAD 02B 2nd Floor Locker Room Blow-Off Tank Insulation NAD 02C 2nd Floor Locker Room Blow-Off Tank Insulation NAD 03A 2nd Floor Locker Room Blue Block Pipe Insulation NAD 03B 2nd Floor Locker Room Blue Block Pipe Insulation NAD 03C 2nd Floor Locker Room Blue Block Pipe Insulation NAD 04A Interior, Emergency Generator Room White Door Frame Caulk NAD 04B Interior, Emergency Generator Room White Door Frame Caulk NAD 04C Interior, Emergency Generator Room White Door Frame Caulk NAD 05A Boiler House by Stairwell Red Fire Stop NAD 05B Boiler House by Stairwell Red Fire Stop NAD 05C Boiler House by Stairwell Red Fire Stop NAD 06A Exterior, Corner of Building White Door Frame Caulk 3% Chrysotile 06B Exterior, Corner of Building White Door Frame Caulk NA/PS 06C Exterior, Corner of Building White Door Frame Caulk NA/PS 07A Exterior, Roll-Up Door Lintel Mortar NAD 07B Exterior, Roll-Up Door Lintel Mortar NAD 07C Exterior, Roll-Up Door Lintel Mortar NAD 08A Exterior, Roll-Up Door Gray Lintel Caulk NAD 08B Exterior, Roll-Up Door Gray Lintel Caulk NAD 08C Exterior, Roll-Up Door Gray Lintel Caulk NAD 09A Exterior, Bldg. South-west Tan Window Frame Caulk NAD 09B Exterior, Bldg. South-west Tan Window Frame Caulk NAD 09C Exterior, Bldg. South-west Tan Window Frame Caulk NAD 10A Exterior, Emergency Generator Room Gray Door Frame Caulk NAD 10B Exterior, Emergency Generator Room Gray Door Frame Caulk NAD 10C Exterior, Emergency Generator Room Gray Door Frame Caulk NAD
© 2020, Mabbett & Associates, Inc. Appendix A Page 2 of 2 May 15, 2020
APPENDIX A
Summary of ACM Sampling Results
A/E Design Services to Correct FCA Deficiencies, Building 8 East Orange Veterans Affairs Medical Center
Sample No. Sample Location Description of Material
Percent and Type of
Asbestos
11A.1 Roof, Stairwell Penthouse Yellow Stucco (Cementitious Layer) NAD
11B.1 Roof, Stairwell Penthouse Yellow Stucco (Cementitious Layer) NAD
11C.1 Roof, Stairwell Penthouse Yellow Stucco (Cementitious Layer) NAD
11A.2 Roof, Stairwell Penthouse Yellow Stucco (Joint Compound Layer) 2% Chrysotile
11B.2 Roof, Stairwell Penthouse Yellow Stucco (Joint Compound Layer) NA/PS
11C.2 Roof, Stairwell Penthouse Yellow Stucco (Joint Compound Layer) NA/PS
12A Roof, Stairwell Penthouse Gray Door Frame Caulk 3% Chrysotile 12B Roof, Stairwell Penthouse Gray Door Frame Caulk NA/PS 12C Roof, Stairwell Penthouse Gray Door Frame Caulk NA/PS 13A Roof, Stairwell Penthouse Gray Flashing Caulk NAD 13B Roof, Stairwell Penthouse Gray Flashing Caulk NAD 13C Roof, Stairwell Penthouse Gray Flashing Caulk NAD 14A Roof, at Vent 1 Black Built-Up Roof NAD 14B Roof, between Vents 1 and 2 Black Built-Up Roof NAD 14C Roof, at Vent 2 Black Built-Up Roof NAD 15A Roof, at Vent 2 Silver Flashing (Roof) NAD 15B Roof, between Vents 1 and 2 Silver Flashing (Roof) NAD 15C Roof, at Vent 1 Silver Flashing (Roof) NAD 16A Roof, at Boiler 1 Gray Boiler Stack Caulk NAD 16B Roof, at Boiler 2 Gray Boiler Stack Caulk NAD 16C Roof, at Boiler 4 Gray Boiler Stack Caulk NAD Notes: NAD = No Asbestos Detected
NA/PS = Not Analyzed, Positive Stop
© 2020, Mabbett & Associates, Inc. APPENDIX B May 15, 2020
APPENDIX B
PLM Laboratory Report and Chain of Custody
© 2020, Mabbett & Associates, Inc. APPENDIX C May 15, 2020
APPENDIX C
Lead Paint Chip Laboratory Report and Chain of Custody
AmeriSci Richmond
Analysis Report
Client:
Project/Test Address:
Ameri-Sci
7469 Whitepine Rd
Telephone: 800.347.4010 Richmond, VA 23237
Environmental Hazards Services, L.L.C.
120-05-1039; R2019057.002; East Orange VBMC; Bldg 8 Boiler House
Client Number:
48-3042
Fax Number:
804-763-1800Laboratory Results
Analyzed Date:
Client Sample Number
Lab Sample Number
Pb (ug/g) ppm
Lead Paint Chip
05/05/2020
05/04/2020
20-05-00283
Reported Date:
Received Date:
Report Number:
13635 Genito Road Midlothian, VA 23112-400
Narrative
ID
05/05/2020
Collection Location % Pb by Wt.
04/30/2020Collection Date:
PB-01 GRAY
CONCRETE
20-05-00283-001 BOILER HOUSE OH DOOR 87 0.0087
PB-02 GREEN
METAL ST
20-05-00283-002 BETWEEN BOILERS 1 & 2 190000 19
PB-03 GRAY
CONCRETE
20-05-00283-003 MEZZ @ BOILER 1 600 0.060
PB-04 GRAY
CONCRETE
20-05-00283-004 MEZZ NW AREA 630 0.063
PB-05 WHITE
METAL ST
20-05-00283-005 MEZZ NW AREA 21000 2.1
PB-06 GREEN
METAL RA
20-05-00283-006 MEZZ @ BOILER 4 <97 <0.0097
PB-07 WHITE
METAL DO
20-05-00283-007 BOILER HOUSE SW AREA 970 0.097
PB-08 SILVER
METAL D
20-05-00283-008 BOILER 2 & 3 4200 0.42
PB-09 GRAY
METAL DOO
20-05-00283-009 ROOF ACCESS PH 300000 30
PB-10 SILVER
RUBBER
20-05-00283-010 ROOF BETWEEN BOILERS 1
& 2
<50 <0.0050
Page 2of1
Report Number:
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: 20-05-00283
120-05-1039; R2019057.002; East Orange VBMC; Bldg 8 Boiler House
48-3042
Collection LocationClient Sample Number
Lab Sample Number
% Pb by Wt.
Narrative
ID
Pb (ug/g) ppm
Missy Kanode QA/QC Clerk
Analysis Method: EPA SW846 7000B
The HUD lead guidelines for lead paint chips are 0.50% by Weight, 5000 ppm, or 1.0 mg/cm². The Reporting Limit (RL) for samples prepared by ASTM E-1979-17 is 10.0 ug Total Pb. The RL for samples prepared by EPA SW846 3050B is 25.0 ug Total Pb. Paint chip area and results are calculated based on area measurements determined by the client. All internal quality control requirements associated with this batch were met, unless otherwise noted.
LEGEND Pb= lead ug = microgram ppm = parts per million ug/g = micrograms per gram Wt. = weight
Reviewed By Authorized Signatory:
Preparation Method: ASTM E-1979-17
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Results represent the analysis of samples submitted by the client. Sample location, description, area, etc., was provided by the client. Results reported above in mg/cm3 are calculated based on area supplied by client. This report shall not be reproduced except in full, without the written consent of the Environmental Hazards Service, L.L.C.
ELLAP Accredtitation through AIHA-LAP, LLC (100420), NY ELAP #11714.
Page 2of2
| 1.0 INTRODUCTION |
| 2.0 ASBESTOS SURVEY |
| 2.1 Sampling Methodology |
| 2.2 Analytical Methodology |
| 2.3 Summary of Asbestos Containing Materials Findings |
| 3.0 LEAD CONTAINING PAINT SURVEY |
| 4.0 CONCLUSIONS AND RECOMMENDATIONS |
| 4.1 Asbestos |
| 4.2 Lead Containing Paint |
| 5.0 LIMITATIONS |
| ASB-1 ACM Survey 0499-0122 GROUND FLOOR-ASB-1.pdf |
| Sheets and Views |
| ASB-1 |
| ASB-2 ACM Survey 0499-0122 ROOF (1)-ASB-2.pdf |
| Sheets and Views |
| ASB-2 |