About this file

This document outlines a federal contract opportunity for corrective facility condition deficiency work at the VA East Orange Campus in New Jersey. The solicitation seeks bids for mechanical, electrical, plumbing, and structural repairs to Building 8's boiler plant, with an estimated cost between $1-2 million. Responses are due by the date specified in solicitation number 36C24220B0062, to be posted on October 15, 2020. The work includes temporary systems, pipe replacements, equipment demolitions and installations, electrical upgrades, and proprietary boiler and control systems to be provided by Miller & Chitty Company. The contract has a 180-day completion period and is set aside for Service-Disabled Veteran Owned Small Businesses. The Department of Veterans Affairs Veterans Health Administration VISN 2 is the contracting agency.

View the file

Other files

File Type Posted
36C24220B0062 0003.docx DOCX document
S05 RFIs-36C24220B0062 Responses.pdf PDF
36C24220B0062 0002.docx DOCX document
36C24220B0062 0001.docx DOCX document
36C24220B0062_1.docx DOCX document
S02 Wage Determination.pdf PDF
S02 _SINGLE SPEC Boiler FCA_rev1.pdf PDF
S02 Correct Boiler FCA Deficiencies Drawings - Issued for Bid.pdf PDF
P03 Brand Name PM_Part806.3_Atch2_FAR6_JA_OVER_SAT.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

p

REGULATED BUILDING MATERIALS

SURVEY REPORT

East Orange VA Medical Center Building 8 Boiler House

A/E Design Services, Correct FCA Deficiencies VA Project No. 561-18-180 385 Tremont Ave.

East Orange, NJ

May 15, 2020 Mabbett Project No. R2019057.002.001

Prepared for:

Miller-Remick, LLC.

1010 Kings Highway South Cherry Hill, NJ 08034

Mabbett & Associates, Inc.

105 Central Street, Suite 4100 Stoneham, MA 02180-1260 T. 781-275-6050 Massachusetts | Virginia | Rhode Island | New Jersey

© 2020, Mabbett & Associates, Inc.

www.mabbett.com

REGULATED BUILDING MATERIALS SURVEY REPORT

VAMC A/E Design Services, Bldg. 8 Correct FCA Deficiencies| East Orange, N.J.

© 2020, Mabbett & Associates, Inc. Page i May 15, 2020 Project No. R2019057.002.001 S:\ADMINA\2019057 Miller-Remick\002\001\Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc

ACKNOWLEDGEMENT

This Regulated Building Materials Survey Report has been prepared by Mabbett & Associates, Inc. (Mabbett®) for the A/E Design Services to Correct FCA Deficiencies, Building 8 at the East Orange Veterans Affairs Medical Center located in East Orange, New Jersey, VA Project No. 561-18-180. The information presented herein is based on the facts and information conveyed to or received by Mabbett during the preparation of this report. If any of the information provided to Mabbett that was used in preparing this report is incorrect, incomplete, or subject to change, Mabbett would wish to alter its opinion(s) accordingly. In addition, the professional opinions and information contained in this report are based solely on the requirements of the applicable regulations and technical data as known to Mabbett as of the date of this report and considered applicable to this report.

The attached Regulated Building Materials Survey Report was prepared by the following Mabbett personnel:

Kevin M. Donovan Environmental, Health & Safety Specialist

This report has been reviewed and approved by:

Michael F. Delaney Director, Building Sciences Group

© 2020, Mabbett & Associates, Inc. Page ii May 15, 2020 Project No. R2019057.002.001 S:\ADMINA\2019057 Miller-Remick\002\001\Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc

TABLE OF CONTENTS

SECTION PAGE

1.0 INTRODUCTION

2.0 ASBESTOS SURVEY

2.1 Sampling Methodology

2.2 Analytical Methodology

2.3 Summary of Asbestos Containing Materials Findings

3.0 LEAD CONTAINING PAINT SURVEY

4.0 CONCLUSIONS AND RECOMMENDATIONS

4.1 Asbestos

4.2 Lead Containing Paint

5.0 LIMITATIONS

TABLES

Table 1 – Summary of ACM (in text) Table 2 – Summary of Lead Paint Chip Analytical Results (in text)

FIGURES

ASB-1 Ground Floor, Asbestos and Lead Sampling Location Plan ASB-2 Roof, Asbestos and Lead Sampling Location Plan

APPENDICES

Appendix A – Summary of ACM Building Survey Results, Including Negative Results Appendix B – PLM Laboratory Report and Chain of Custody Appendix C – Lead Paint Chip Laboratory Report and Chain of Custody

© 2020, Mabbett & Associates, Inc. Page 1 May 15, 2020 Project No. R2019057.002.001 S:\ADMINA\2019057 Miller-Remick\002\001\Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc

1.0 INTRODUCTION

Mabbett and Associates, Inc. (Mabbett®) performed a survey for regulated building materials (RBM) as part of the A/E Design to Correct FCA Deficiencies, Building 8 at the East Orange Veterans Affairs Medical Center (VAMC) located in East Orange, New Jersey, VA Project No. 561-18-180. Site survey work was performed on April 30, 2020 by appropriately credentialed regulated building materials inspectors, and consisted of the following activities:

A review of the existing 95% A/E Construction Documents;

An Asbestos Containing Material (ACM) survey of suspect materials (Analysis by Polarized Light Microscopy

[PLM] and Transmission Electron Microscopy [TEM]); and Limited Lead Containing Paint (LCP) sampling (Analysis by atomic absorption [AA]).

The survey was limited to Building 8, Boiler House and areas anticipated to be disturbed and identified on the 95% construction set drawings, dated April 10, 2020 which was provided to Mabbett prior to the survey. Areas and materials outside of this scope of work were not surveyed by Mabbett.

2.0 ASBESTOS SURVEY

A visual screening inspection was conducted by EPA trained and accredited asbestos inspectors to identify locations of suspect ACM and conceptualize the sampling program. Only areas that were accessible during the field work phase were inspected, with reasonable efforts made during the initial field survey work to access areas as necessary to complete the asbestos survey and sampling program.

Prior to the execution of this survey, provided Building 8 plans were examined and VA engineering personnel interviewed to discern the age and condition of existing materials, as well as the renovation history of the areas being surveyed.

2.1 Sampling Methodology

Site inspection work was performed on April 30, 2020, by EPA trained and accredited asbestos inspector Mr. Kevin Donovan. Bulk asbestos samples were collected using EPA National Emissions Standards for Hazardous Air Pollutants (NESHAP), 40 CFR Part 763, and Asbestos Hazard Emergency Response Act (AHERA) protocols. The inspection was limited to areas that may be impacted by the proposed renovation project. Bulk suspect ACM sampling was generally conducted according to the following sampling protocol:

Friable surfacing material:

At least three bulk samples shall be collected from each homogeneous area that is 1,000 ft2 or less.

At least five bulk samples shall be collected from each homogeneous area that is greater than 1,000 ft2 but less than or equal to 5,000 ft2.

At least seven bulk samples shall be collected from each homogeneous area that is greater than

5,000 ft2.

Thermal system insulation:

At least three bulk samples shall be collected from each homogeneous area of thermal system insulation.

At least one bulk sample shall be collected from each homogeneous area of patched area of thermal system insulation.

Sufficient samples shall be collected from elbows and fittings to determine if they contain ACM.

Bulk samples shall not be collected from any homogeneous area where the state licensed asbestos inspector determined that the thermal system insulation is fiberglass, foam glass, rubber, or other non-ACM.

© 2020, Mabbett & Associates, Inc. Page 2 May 15, 2020 Project No. R2019057.002.001 S:\ADMINA\2019057 Miller-Remick\002\001\Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc

Miscellaneous material:

At least two bulk sample shall be collected from each homogeneous area that is less than 100 ft2.

At least three bulk samples shall be collected from each homogeneous area that is greater than 100 ft2.

Areas that were inaccessible, or where the survey was limited to visual observation only, are identified below:

Within walls Within fire doors Enclosed pipe/duct chases Inside mechanical equipment/ductwork Above fixed drywall or plaster ceilings Electrical equipment

2.2 Analytical Methodology

The collected bulk samples were submitted under chain of custody (COC) procedures to AmeriSci of Midlothian, VA for polarized light microscopy (PLM) analysis of bulk materials using EPA Methods 600/R-93/116. AmeriSci is accredited by the American Industrial Hygiene Association (AIHA) and participates in the National Voluntary Laboratory Accreditation Program (NVLAP) and is licensed by the New Jersey Department of Environmental Protection (NJDEP) (Certification No. VA012) for asbestos analysis.

All bulk sample results from this inspection are summarized in Appendix A, Summary of ACM Building Survey Results.

The EPA, Occupational Safety and Health Administration (OSHA), and the NJDEP defines any material that contains greater than one percent (>1%) asbestos as being an ACM. As such, the analytical laboratory identified bulk samples as positive for asbestos that met the regulatory criteria of greater than one percent (>1%) asbestos. Laboratory reports and COC documentation are provided in Appendix B of this report.

2.3 Summary of Asbestos Containing Materials Findings

Mabbett identified sixteen (16) areas of homogenous materials and collected fifty-one (51) representative bulk ACM samples. Asbestos sampling locations and results are identified on Figures ASB-1 and ASB-2. The laboratory reported analytical data indicated that there (3) homogenous materials had greater than 1% asbestos and were identified as ACM. Estimated quantities of materials identified as ACM are presented in Table 1 below:

TABLE 1

Summary of ACM

A/E Design Services to Correct FCA Deficiencies, Building 8 East Orange Veterans Affairs Medical Center

Location Description of Material Percent and Type of Asbestos

Estimated Quantity Amount Units

Exterior, East Side of Building White Door Frame Caulk 3% Chrysotile 25 Linear Feet

Roof, Penthouse Siding Yellow Stucco (Joint Compound Layer) 2% Chrysotile 400 Square Feet

Roof, Penthouse Gray Door Frame Caulk 3% Chrysotile 20 Linear Feet

© 2020, Mabbett & Associates, Inc. Page 3 May 15, 2020 Project No. R2019057.002.001 S:\ADMINA\2019057 Miller-Remick\002\001\Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc

3.0 LEAD CONTAINING PAINT SURVEY

The limited LCP survey included the collection of paint chips from painted surfaces and systems in Building 8 that may be impacted by the planned renovation. Ten (10) samples of different homogenous areas of paint were collected during this survey. Paint chip samples were submitted under standard COC procedures to Environmental Hazards Services, LLC (EHS), via AmeriSci. Analysis was conducted using EPA Method SW846 7000B: Flame Atomic Absorption Spectrophotometry.

The results of the limited LCP sampling are summarized in Table 2, with laboratory reports provided in Appendix C.

TABLE 2

Summary of Lead Paint Chip Analytical Results

A/E Design Services to Correct FCA Deficiencies, Building 8 East Orange Veterans Affairs Medical Center

Sample # Location Substrate and Component Color Result

(% Pb by Wt.)

Pb-01 Overhead Door Concrete Floor Gray 0.0087 Pb-02 Between Boilers 1 and 2 Metal Stair Frame Green 19 Pb-03 Mezzanine Concrete Deck Gray 0.06 Pb-04 Mezzanine Concrete Beam Gray 0.063 Pb-05 Mezzanine Metal Stairs White 2.1 Pb-06 Mezzanine Metal Railing Green <0.0097 Pb-07 Boiler House Metal Door Frame White 0.097 Pb-08 Boilers 2 and 3 Metal Drain Pipe Silver 0.42 Pb-09 Roof Access Metal Door Gray 30 Pb-10 Roof Vent Rubber Vent Base Silver <0.0050

The Occupational Safety & Health Administration (OSHA) does not recognize a “safe” level of lead in paint.

Depending on the method of removal used, even trace amounts of lead in paint may result in airborne concentrations of lead during removal. An employer or contractor who disturbs or removes lead paint must comply with OSHA Standard 29 CFR 1926.62, “Lead Exposure in Construction; Interim Final Rule.”

4.0 CONCLUSIONS AND RECOMMENDATIONS

4.1 Asbestos

Identified ACM must be abated and properly disposed of prior to disturbance by state licensed and properly trained contractors. All abatement must be performed in accordance with federal, state and local requirements. Any suspect materials encountered during demolition or renovation activities that were not identified in this report as being non- ACM, should be assumed to be ACM unless sample results prove otherwise. Suspect ACM that may be present within operating equipment, walls, above inaccessible hard ceilings, or in other inaccessible locations, should be assumed to contain asbestos if discovered during any demolition or renovation process or until otherwise verified.

4.2 Lead Containing Paint

The purpose of the limited LCP survey was to identify similar areas of LCP. During the on-site survey, representative samples of similar areas of interior and exterior building coatings were collected and analyzed for lead content. The regulations addressing LCP in non-residential buildings are focused on occupational exposures involved with paint-disturbing activities and related waste-disposal activities.

© 2020, Mabbett & Associates, Inc. Page 4 May 15, 2020 Project No. R2019057.002.001 S:\ADMINA\2019057 Miller-Remick\002\001\Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc

Occupational exposure to lead during construction is regulated by OSHA regulation 29 CFR 1926.62 “Lead in Construction,” as well as other applicable state and local regulations. These regulations involve air monitoring to determine worker exposure levels when disturbing paint containing measurable levels of lead. This LCP survey cannot determine a safe level of lead for the purpose of paint-disturbing activities. However, this report is intended to provide guidance as to the location of LCP so it can be controlled, abated or disposed of properly during this project’s construction related activities. Information gathered during this LCP survey should be used to determine where worker exposures to airborne lead may occur. Additionally, this information should also be used to assess the potential for exposure to workers, and for determining appropriate controls necessary to limit his or her health risks during this project.

A concentration of lead greater than or equal to 0.5 percent by weight or 1.0 mg/cm2 exceeds EPA and HUD residential standards and is considered an indicator of risk. Representative samples of LCP waste to be generated during building renovation, or following demolition but prior to disposal, should be collected and analyzed using toxicity characteristic leaching procedure (TCLP) in accordance with 40 CFR Part 261. Management and disposal of lead containing waste must be done in accordance with all applicable local, state, and federal regulations.

OSHA regulations may require certain procedures for any paint that contains lead, even if it is below these levels. All LCP identified, regardless of the lead content, should either be sampled and analyzed by TCLP and then handled/disposed of accordingly, or segregated from other large-scale debris and then managed as hazardous waste in accordance with federal, state and local hazardous waste disposal regulations.

5.0 LIMITATIONS

This survey report is the result of a diligent and thorough inspection for regulated building materials of the designated areas and materials that may be impacted by the renovation project. Inaccessible areas were not included in this survey. Although a comprehensive inspection of these areas was performed, Mabbett does not claim to have identified all hazardous materials that could be present in the facility (for example, materials potentially located within the inaccessible areas). Mabbett has conducted this assessment with reasonable care and has performed this project in accordance with generally accepted industry standards. There can be no assurances, and Mabbett makes no assurances, that the information, research, and technology used to prepare this report may not change in the future, thus affecting the results reported herein.

© 2020, Mabbett & Associates, Inc. FIGURES May 15, 2020 Project No. R2019057.002.001 Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc

FIGURES

NO. DESCRIPTION DATE

o n e e i g h t h i n c e f o t

B

A

C

D

E

F t h r e e i n c h e s o t o n e a d a l f i n c h e o t o n e i n o t t h r e e q u a r t e r s i n o t o n e h a l f i n o t t h r e e e i g h t h s i n o t o n e q u a r t e r i n o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

97 8654321

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE

WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE

PROFESSIONAL ENGINEER.

Miller-Remick LLC

1010 KINGS HIGHWAY SOUTH

CHERRY HILL, NEW JERSEY 08034

PHONE: (856)429-4000

FAX: (856)429-5002

M.E.P. & Structural Engineering

A Service Disabled Veteran Owned

Small Business

A

S r v i c e

D i s a b l

V t e r a

O w n m a l

B u s i n e s s

SDVOSB

CVE

MR PROJECT NO: 0499-0122

B

A

C

D

E

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseENGINEER OF RECORDCONSULTANT CORRECT FCA DEFICIENCIES

VA EAST ORANGE CAMPUS

561-18-180

BUILDING 8

Project Director

2020-04-15

95% CONSTRUCTION

DOCUMENTS

NOT FOR CONSTRUCTION

ASBESTOS & LEAD SURVEY PLAN

BUILDING-8

GROUND FLOOR

MFD DJA

ASB-1

Scientists I Engineers I Program Managers

Mabbett & Associates, Inc.

105 Central Street Stoneham, MA 02180

T. 781-275-6050 www.mabbett.com

Mabbett

R

PLAN

NORTH

ACTUAL

NORTH

KEYPLAN

05A*

05A**

05A

05A

06A*

Pb-01

04B, 04C

04A

10A

10B, 10C

05A, 05B

05C Pb-07

07A, 08A, 08B, 08C

07B 07C

Pb-01

09A 09B 09C

02B

03C

02C 03B

06B**, 06C**

03A

02A

Pb-06Pb-08Pb-02Pb-03Pb-04Pb-05

01C01A, 01B

SECOND FLOOR LOCKER ROOM

SAMPLES,

02A, 02B, 02C

03A, 03B, 03C

AutoCAD SHX Text

STAIRS

AutoCAD SHX Text

STAIRS

AutoCAD SHX Text

BOILER

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

EMERGENCY

AutoCAD SHX Text

GENERATOR

AutoCAD SHX Text 8-02

AutoCAD SHX Text

CONDENSATE

AutoCAD SHX Text

PUMP

AutoCAD SHX Text

ROOM

AutoCAD SHX Text 8-03A

AutoCAD SHX Text

STAIRWAY

AutoCAD SHX Text

MAIN

AutoCAD SHX Text 8-04

AutoCAD SHX Text 8-01

AutoCAD SHX Text 8-03

AutoCAD SHX Text 8-B1

AutoCAD SHX Text 8-B2

AutoCAD SHX Text 8-B3

AutoCAD SHX Text 8-B4

AutoCAD SHX Text

(EX)

AutoCAD SHX Text

(EX)

AutoCAD SHX Text

EX.BLOW-OFF TANK

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

600HP BOILER

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

600HP BOILER

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

600HP BOILER

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

600HP BOILER

AutoCAD SHX Text

(EXISTING)

AutoCAD SHX Text

CONTROL ROOM

AutoCAD SHX Text

BOILER MASTER

AutoCAD SHX Text

CONTROL PANEL

AutoCAD SHX Text

MCC

AutoCAD SHX Text

(E) FIRE HYDRANT

AutoCAD SHX Text

(E) TRANSFORMER

AutoCAD SHX Text

(E) PROPANE STORAGE

AutoCAD SHX Text

(E) CONDENSING UNIT

AutoCAD SHX Text

(E) CONDENSING UNIT

AutoCAD SHX Text

(E) UNDERGROUND FUEL TANKS

AutoCAD SHX Text

(E) GENERATOR FUEL TANK

AutoCAD SHX Text

(E) ELECTRICAL PANELS

AutoCAD SHX Text

(E) FD

AutoCAD SHX Text

(E) PUMP

AutoCAD SHX Text

(E) PUMP

AutoCAD SHX Text

(E) FD

AutoCAD SHX Text

(E) SURGE TANK

AutoCAD SHX Text

(E) FD

AutoCAD SHX Text

(E) FD

AutoCAD SHX Text

(E) FD

AutoCAD SHX Text

(E)FD

AutoCAD SHX Text

(E) PUMPS

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

AutoCAD SHX Text

ASBESTOS & LEAD SURVEY PLAN - GROUND FLOOR

AutoCAD SHX Text 3/16" = 1'-0"

AutoCAD SHX Text

STOP POSITIVE SAMPLE FOR ASBESTOS

AutoCAD SHX Text

NO ASBESTOS DETECTED (NAD)

AutoCAD SHX Text

SAMPLE POSITIVE FOR ASBESTOS

AutoCAD SHX Text

APPROXIMATE SAMPLE LOCATION

AutoCAD SHX Text

GENERAL SHEET NOTES:

AutoCAD SHX Text LEAD (Pb) SAMPLING LOCATION

NO. DESCRIPTION DATE

n e e i g h t i o t

B

A

C

D

E

F t h r e e i n c h e o t o n e a a l f i n c h e o t o n e i n o t t h r e e q u a r t e r s i n o t o n e h a l f i n o t t h r e e e i g h t h s i n o t o n e q u a r t e r i n o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

97 8654321

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE

WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE

PROFESSIONAL ENGINEER.

Miller-Remick LLC

1010 KINGS HIGHWAY SOUTH

CHERRY HILL, NEW JERSEY 08034

PHONE: (856)429-4000

FAX: (856)429-5002

M.E.P. & Structural Engineering

A Service Disabled Veteran Owned

Small Business

A r v i c e

D i s a b l

V t e r a

O w n m a

B u s i n e s s

SDVOSB

CVE

MR PROJECT NO: 0499-0122

B

A

C

D

E

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseENGINEER OF RECORDCONSULTANT CORRECT FCA DEFICIENCIES

VA EAST ORANGE CAMPUS

561-18-180

BUILDING 8

Project Director

2020-04-15

95% CONSTRUCTION

DOCUMENTS

NOT FOR CONSTRUCTION

ASBESTOS AND LEAD SURVEY PLAN

BUILDING-8

ROOF

MFD DJA

ASB-2

Scientists I Engineers I Program Managers

Mabbett & Associates, Inc.

105 Central Street Stoneham, MA 02180

T. 781-275-6050 www.mabbett.com

Mabbett

R

PLAN

NORTH

ACTUAL

NORTH

KEYPLAN

05A*

05A**

05A

05A

Pb-01

12A*, 12B**, 13A

11A.1, 11A.2*

Pb-09

16A 16B 16C

11C.1, 11C.2** 12C**, 13B, 13C

14A

15C

Pb-10

15A 15B 14C

14B

11B.1, 11B.2**

AutoCAD SHX Text

ROOF PLAN

AutoCAD SHX Text (E)

AutoCAD SHX Text

RELIEF VENTS

AutoCAD SHX Text (E)

AutoCAD SHX Text

RELIEF VENTS

AutoCAD SHX Text (E)

AutoCAD SHX Text

RELIEF VENTS

AutoCAD SHX Text (E)

AutoCAD SHX Text

RELIEF VENTS

AutoCAD SHX Text (E)

AutoCAD SHX Text

BOILER STACK

AutoCAD SHX Text (E)

AutoCAD SHX Text

BOILER STACK

AutoCAD SHX Text (E)

AutoCAD SHX Text

BOILER STACK

AutoCAD SHX Text (E)

AutoCAD SHX Text

BOILER STACK

AutoCAD SHX Text (E)

AutoCAD SHX Text

RELIEF VENT

AutoCAD SHX Text

(E)EXISTING MAKE-UP AIR HEATER HV-1

AutoCAD SHX Text

(E)EXISTING MAKE-UP AIR HEATER HV-2

AutoCAD SHX Text (E)

AutoCAD SHX Text

EXHAUST FAN

AutoCAD SHX Text (E)

AutoCAD SHX Text

EXHAUST FAN

AutoCAD SHX Text (E)

AutoCAD SHX Text

EXHAUST FAN

AutoCAD SHX Text (E)

AutoCAD SHX Text

EXHAUST FAN

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

AutoCAD SHX Text

ASBESTOS AND LEAD SURVEY PLAN - ROOF PLAN

AutoCAD SHX Text 3/16" = 1'-0"

AutoCAD SHX Text

STOP POSITIVE SAMPLE FOR ASBESTOS

AutoCAD SHX Text

NO ASBESTOS DETECTED (NAD)

AutoCAD SHX Text

SAMPLE POSITIVE FOR ASBESTOS

AutoCAD SHX Text

APPROXIMATE SAMPLE LOCATION

AutoCAD SHX Text

GENERAL SHEET NOTES:

AutoCAD SHX Text LEAD (Pb) SAMPLING LOCATION

© 2020, Mabbett & Associates, Inc. APPENDIX A May 15, 2020 Project No. R2019057.002.001 Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc

APPENDIX A

Summary of ACM Building Survey Results, Including Negative Results

© 2020, Mabbett & Associates, Inc. Appendix A Page 1 of 2 May 15, 2020 Project No. R2019057.002.001 Miller-Remick East Orange VAMC Correct FCA Deficiencies V1 - Final.doc

APPENDIX A

Summary of ACM Sampling Results A/E Design Services to Correct FCA Deficiencies, Building 8

East Orange Veterans Affairs Medical Center

Sample No. Sample Location Description of Material

Percent and Type of

Asbestos

01A Boiler 2 White Fiberglass End Sealant NAD

01B Boiler 2 White Fiberglass End Sealant NAD

01C Boiler 3 White Fiberglass End Sealant NAD

02A 2nd Floor Locker Room Blow-Off Tank Insulation NAD 02B 2nd Floor Locker Room Blow-Off Tank Insulation NAD 02C 2nd Floor Locker Room Blow-Off Tank Insulation NAD 03A 2nd Floor Locker Room Blue Block Pipe Insulation NAD 03B 2nd Floor Locker Room Blue Block Pipe Insulation NAD 03C 2nd Floor Locker Room Blue Block Pipe Insulation NAD 04A Interior, Emergency Generator Room White Door Frame Caulk NAD 04B Interior, Emergency Generator Room White Door Frame Caulk NAD 04C Interior, Emergency Generator Room White Door Frame Caulk NAD 05A Boiler House by Stairwell Red Fire Stop NAD 05B Boiler House by Stairwell Red Fire Stop NAD 05C Boiler House by Stairwell Red Fire Stop NAD 06A Exterior, Corner of Building White Door Frame Caulk 3% Chrysotile 06B Exterior, Corner of Building White Door Frame Caulk NA/PS 06C Exterior, Corner of Building White Door Frame Caulk NA/PS 07A Exterior, Roll-Up Door Lintel Mortar NAD 07B Exterior, Roll-Up Door Lintel Mortar NAD 07C Exterior, Roll-Up Door Lintel Mortar NAD 08A Exterior, Roll-Up Door Gray Lintel Caulk NAD 08B Exterior, Roll-Up Door Gray Lintel Caulk NAD 08C Exterior, Roll-Up Door Gray Lintel Caulk NAD 09A Exterior, Bldg. South-west Tan Window Frame Caulk NAD 09B Exterior, Bldg. South-west Tan Window Frame Caulk NAD 09C Exterior, Bldg. South-west Tan Window Frame Caulk NAD 10A Exterior, Emergency Generator Room Gray Door Frame Caulk NAD 10B Exterior, Emergency Generator Room Gray Door Frame Caulk NAD 10C Exterior, Emergency Generator Room Gray Door Frame Caulk NAD

© 2020, Mabbett & Associates, Inc. Appendix A Page 2 of 2 May 15, 2020

APPENDIX A

Summary of ACM Sampling Results

A/E Design Services to Correct FCA Deficiencies, Building 8 East Orange Veterans Affairs Medical Center

Sample No. Sample Location Description of Material

Percent and Type of

Asbestos

11A.1 Roof, Stairwell Penthouse Yellow Stucco (Cementitious Layer) NAD

11B.1 Roof, Stairwell Penthouse Yellow Stucco (Cementitious Layer) NAD

11C.1 Roof, Stairwell Penthouse Yellow Stucco (Cementitious Layer) NAD

11A.2 Roof, Stairwell Penthouse Yellow Stucco (Joint Compound Layer) 2% Chrysotile

11B.2 Roof, Stairwell Penthouse Yellow Stucco (Joint Compound Layer) NA/PS

11C.2 Roof, Stairwell Penthouse Yellow Stucco (Joint Compound Layer) NA/PS

12A Roof, Stairwell Penthouse Gray Door Frame Caulk 3% Chrysotile 12B Roof, Stairwell Penthouse Gray Door Frame Caulk NA/PS 12C Roof, Stairwell Penthouse Gray Door Frame Caulk NA/PS 13A Roof, Stairwell Penthouse Gray Flashing Caulk NAD 13B Roof, Stairwell Penthouse Gray Flashing Caulk NAD 13C Roof, Stairwell Penthouse Gray Flashing Caulk NAD 14A Roof, at Vent 1 Black Built-Up Roof NAD 14B Roof, between Vents 1 and 2 Black Built-Up Roof NAD 14C Roof, at Vent 2 Black Built-Up Roof NAD 15A Roof, at Vent 2 Silver Flashing (Roof) NAD 15B Roof, between Vents 1 and 2 Silver Flashing (Roof) NAD 15C Roof, at Vent 1 Silver Flashing (Roof) NAD 16A Roof, at Boiler 1 Gray Boiler Stack Caulk NAD 16B Roof, at Boiler 2 Gray Boiler Stack Caulk NAD 16C Roof, at Boiler 4 Gray Boiler Stack Caulk NAD Notes: NAD = No Asbestos Detected

NA/PS = Not Analyzed, Positive Stop

© 2020, Mabbett & Associates, Inc. APPENDIX B May 15, 2020

APPENDIX B

PLM Laboratory Report and Chain of Custody

© 2020, Mabbett & Associates, Inc. APPENDIX C May 15, 2020

APPENDIX C

Lead Paint Chip Laboratory Report and Chain of Custody

AmeriSci Richmond

Analysis Report

Client:

Project/Test Address:

Ameri-Sci

7469 Whitepine Rd

Telephone: 800.347.4010 Richmond, VA 23237

Environmental Hazards Services, L.L.C.

120-05-1039; R2019057.002; East Orange VBMC; Bldg 8 Boiler House

Client Number:

48-3042

Fax Number:

804-763-1800Laboratory Results

Analyzed Date:

Client Sample Number

Lab Sample Number

Pb (ug/g) ppm

Lead Paint Chip

05/05/2020

05/04/2020

20-05-00283

Reported Date:

Received Date:

Report Number:

13635 Genito Road Midlothian, VA 23112-400

Narrative

ID

05/05/2020

Collection Location % Pb by Wt.

04/30/2020Collection Date:

PB-01 GRAY

CONCRETE

20-05-00283-001 BOILER HOUSE OH DOOR 87 0.0087

PB-02 GREEN

METAL ST

20-05-00283-002 BETWEEN BOILERS 1 & 2 190000 19

PB-03 GRAY

CONCRETE

20-05-00283-003 MEZZ @ BOILER 1 600 0.060

PB-04 GRAY

CONCRETE

20-05-00283-004 MEZZ NW AREA 630 0.063

PB-05 WHITE

METAL ST

20-05-00283-005 MEZZ NW AREA 21000 2.1

PB-06 GREEN

METAL RA

20-05-00283-006 MEZZ @ BOILER 4 <97 <0.0097

PB-07 WHITE

METAL DO

20-05-00283-007 BOILER HOUSE SW AREA 970 0.097

PB-08 SILVER

METAL D

20-05-00283-008 BOILER 2 & 3 4200 0.42

PB-09 GRAY

METAL DOO

20-05-00283-009 ROOF ACCESS PH 300000 30

PB-10 SILVER

RUBBER

20-05-00283-010 ROOF BETWEEN BOILERS 1

& 2

<50 <0.0050

Page 2of1

Report Number:

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: 20-05-00283

120-05-1039; R2019057.002; East Orange VBMC; Bldg 8 Boiler House

48-3042

Collection LocationClient Sample Number

Lab Sample Number

% Pb by Wt.

Narrative

ID

Pb (ug/g) ppm

Missy Kanode QA/QC Clerk

Analysis Method: EPA SW846 7000B

The HUD lead guidelines for lead paint chips are 0.50% by Weight, 5000 ppm, or 1.0 mg/cm². The Reporting Limit (RL) for samples prepared by ASTM E-1979-17 is 10.0 ug Total Pb. The RL for samples prepared by EPA SW846 3050B is 25.0 ug Total Pb. Paint chip area and results are calculated based on area measurements determined by the client. All internal quality control requirements associated with this batch were met, unless otherwise noted.

LEGEND Pb= lead ug = microgram ppm = parts per million ug/g = micrograms per gram Wt. = weight

Reviewed By Authorized Signatory:

Preparation Method: ASTM E-1979-17

The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Results represent the analysis of samples submitted by the client. Sample location, description, area, etc., was provided by the client. Results reported above in mg/cm3 are calculated based on area supplied by client. This report shall not be reproduced except in full, without the written consent of the Environmental Hazards Service, L.L.C.

ELLAP Accredtitation through AIHA-LAP, LLC (100420), NY ELAP #11714.

Page 2of2

1.0 INTRODUCTION
2.0 ASBESTOS SURVEY
2.1 Sampling Methodology
2.2 Analytical Methodology
2.3 Summary of Asbestos Containing Materials Findings
3.0 LEAD CONTAINING PAINT SURVEY
4.0 CONCLUSIONS AND RECOMMENDATIONS
4.1 Asbestos
4.2 Lead Containing Paint
5.0 LIMITATIONS
ASB-1 ACM Survey 0499-0122 GROUND FLOOR-ASB-1.pdf
Sheets and Views
ASB-1
ASB-2 ACM Survey 0499-0122 ROOF (1)-ASB-2.pdf
Sheets and Views
ASB-2