36C24219B0056-019.pdf

PDF 18 MB Posted

Attached to
528A7-15-703 MEDICAL CENTER EXTERIOR WAYFINDING SIGNAGE AND GRAPHICS UPGRADE
Solicitation number
36C24219B0056
Issued by

About this file

36C24219B0056 specs Syracuse Project Manual Part 4-4.pdf

View the file

Other files

File Type Posted
36C24220C0013-000.docx DOCX document
36C24219B0056-0004000.docx DOCX document
36C24219B0056-0004000.docx DOCX document
36C24219B0056-0003000.docx DOCX document
36C24219B0056-0003000.docx DOCX document
36C24219B0056-0002001.pdf PDF
36C24219B0056-0002000.docx DOCX document
36C24219B0056-0002000.docx DOCX document
36C24219B0056-0002001.pdf PDF
36C24219B0056-0001000.docx DOCX document
36C24219B0056-0001000.docx DOCX document
36C24219B0056-026.pdf PDF
36C24219B0056-020.pdf PDF
36C24219B0056-018.pdf PDF
36C24219B0056-023.pdf PDF
36C24219B0056-016.pdf PDF
36C24219B0056-022.pdf PDF
36C24219B0056-024.pdf PDF
36C24219B0056-021.pdf PDF
36C24219B0056-015.docx DOCX document
36C24219B0056-027.pdf PDF
36C24219B0056-025.pdf PDF
36C24219B0056-028.pdf PDF
36C24219B0056-019.pdf PDF
36C24219B0056-017.pdf PDF
36C24219B0056-021.pdf PDF
36C24219B0056-028.pdf PDF
36C24219B0056-016.pdf PDF
36C24219B0056-027.pdf PDF
36C24219B0056-015.docx DOCX document
36C24219B0056-024.pdf PDF
36C24219B0056-022.pdf PDF
36C24219B0056-025.pdf PDF
36C24219B0056-026.pdf PDF
36C24219B0056-023.pdf PDF
36C24219B0056-018.pdf PDF
36C24219B0056-020.pdf PDF
36C24219B0056-017.pdf PDF
36C24219B0056-000.docx DOCX document
36C24219B0056-000.docx DOCX document
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

July 2, 2019

Proj 36C24219C0021

Bid

02-01-17 areas and adjoining areas. Construct partitions of gypsum board or treated plywood (flame spread rating of 25 or less in accordance with ASTM E84) on both sides of fire retardant treated wood or metal steel studs. Extend the partitions through suspended ceilings to floor slab deck or roof. Seal joints and penetrations. At door openings, install Class C, ¾ hour fire/smoke rated doors with self closing devices.

2. Install one-hour fire-rated temporary construction partitions as shown on drawings to maintain integrity of existing exit stair enclosures, exit passageways, fire rated enclosures of hazardous areas, horizontal exits, smoke barriers, vertical shafts and opening enclosures.

3. Close openings in smoke barriers and fire-rated construction to maintain fire ratings. Seal penetrations with listed through-penetration firestop materials in accordance with Section 07 84 00, FIRESTOPPING.

E. Temporary Heating and Electrical: Install, use and maintain installations in accordance with 29 CFR 1926, NFPA 241 and

NFPA 70.

F. Means of Egress: Do not block exiting for occupied buildings, including paths from exits to roads. Minimize disruptions and coordinate with Contracting Officer

Representative or Government Designated Authority.

G. Egress Routes for Construction Workers: Maintain free and unobstructed egress. Inspect daily. Report findings and corrective actions weekly to Contracting Officer

Representative or Government Designated Authority.

01 35 26 -33