About this file

36C24219B0028 C27 DRAWINGS 15-47 (MEP).pdf

View the file

Other files

File Type Posted
36C24219B0028-0001001.pdf PDF
36C24219B0028-0001003.pdf PDF
36C24219B0028-0001002.pdf PDF
36C24219B0028-0001000.docx DOCX document
36C24219B0028-021.pdf PDF
36C24219B0028-015.pdf PDF
36C24219B0028-018.pdf PDF
36C24219B0028-020.pdf PDF
36C24219B0028-014.docx DOCX document
36C24219B0028-016.pdf PDF
36C24219B0028-017.pdf PDF
36C24219B0028-019.pdf PDF
36C24219B0028-013.pdf PDF
36C24219B0028-011.pdf PDF
36C24219B0028-006.pdf PDF
36C24219B0028-005.docx DOCX document
36C24219B0028-009.pdf PDF
36C24219B0028-012.pdf PDF
36C24219B0028-008.pdf PDF
36C24219B0028-007.pdf PDF
36C24219B0028-010.pdf PDF
36C24219B0028-002.pdf PDF
36C24219B0028-003.pdf PDF
36C24219B0028-001.pdf PDF
36C24219B0028-000.docx DOCX document
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SYMBOL LIST AND ABBREVIATIONS

EXISTING WORK TO REMAIN

DIRECTION OF FLOW

NEW WORK

FLEXIBLE CONNECTION

FIRE & SMOKE DAMPERS W/ACCESS DOOR

RECTANGULAR ELBOW WITH TURNING VANES

IN DUCT AT WALL

FC

FC

RETURN OR EXHAUST DUCT DOWN

RETURN OR EXHAUST DUCT UP

SUPPLY DUCT DOWN

SUPPLY DUCT UP

CEILING DIFFUSER

CEILING REGISTER

MOTORIZED DAMPER

TEMPERATURE SENSOR

CEILING DIFFUSER W/150 CFM SUPPLY AIR CD CD(150)

ACOUSTICAL LINED DUCT

VOLUME DAMPER

VD

VD

VD

STRAINER WITH BLOW-OFF VALVE

UNION

REDUCER

THREE WAY CONTROL VALVE

COMBINATION MEASURING, BALANCING &

SOLENOID VALVE

COCK VALVE

GATE VALVE / SHUT-OFF VALVE

GLOBE VALVE

CHECK VALVE

WATER PRESSURE GAUGE

TWO WAY CONTROL VALVE

THERMOMETER

BUTTERFLY VALVE

PIPE DOWN

PIPE UP

END CAP

SHUT-OFF VALVE

CAV-6

(600)

CAV

EXISTING WORK TO BE DEMOLISHED

SG

RG

SG(300)

RG(300)

SUPPLY AIR GRILLE 300 CFM

RETURN AIR GRILLE 300 CFM

CONSTANT AIR VOLUME BOX W/REHEAT COIL #

6, 600 CFM

HUMIDITY SENSOR

POINT OF CONNECTION NEW TO EXISTING

POINT OF DISCONNECTION FOR REMOVAL

LOW PRESSURE RETURN

MEDIUM PRESSURE RETURN

MEDIUM PRESSURE STEAMMPS

MPR

LOW PRESSURE STEAM

EXHAUST AIR

ACCESS DOOR

SYMBOL LIST AND ABBREVIATIONS

CUBIC FEET PER MINUTE

ABOVE FINISHED FLOOR

GALLON PER MINITE

ACOUSTICAL LINING

300 CUBIC FEET OF AIR PER MINUTE

CEILING GRILLE

BRITISH THERMAL UNIT

BUILDING AUTOMATION SYSTEM

CEILING DIFFUSER

CEILING REGISTER

HORSE POWER

HEATING COIL

LEAVING WATER TEMPERATURE

LOCKED ROTOR AMPS

LEAVING AIR TEMPERATURE

LRA

LWT

KW

HP

LAT

GPM

HC

EA

DN

CR

KILOWATT

DOWN

CFM

CD

CG

BTU

BAS

AFF

AL

AD

(300)

VFD

W/WMS

WMS

CAV

VARIABLE FREQUENCY DRIVE

WIRE MESH SCREEN

WITH WIRE MESH SCREEN

CONSTANT AIR VOLUME

LVG LEAVING

EEF EFFICIENCY

DWG DRAWING

FC FLEXIBLE CONNECTION

HEATINGHTG

DDC DIRECT DIGITAL CONTROL

FPM FEET PER MINUTE

FT FEET

ELEV ELEVATION

FSD FIRE/SMOKE DAMPER

CHWS

CHWR CHILLED WATER RETURN

CHILLED WATER SUPPLY

OUTSIDE AIR INTAKE

OUTSIDE AIR

NOT TO SCALE

NORMALLY CLOSED

NOT IN THIS CONTRACT

OAI

OA

NTS

NIC

NC

MIN MINIMUM

SA

RA

SUPPLY AIR

RETURN AIR

TYP TYPICAL

MECH MECHANICAL

DET DETAIL

FTR FIN TUBE RADIATION

MAT MIXED AIR TEMPERATURE

MAX MAXIMUM

MBH THOUSANDS BTU PER HOUR

MD MOTORIZED DAMPER

RHC REHEAT COIL

WPD WATER PRESSURE DROP

ABBREV. SYMBOL DESCRIPTIONS ABBREV. SYMBOL DESCRIPTIONS

FSD/AD, SFD, FSD,

F/SD

1. ALL PIPING AND DUCTWORK SHALL BE SUSPENDED FROM BUILDING STRUCTURE ONLY, EXCEPT AS SPECIFICALLY ALLOWED IN THE SPECIFICATIONS. HVAC CONTRACTOR SHALL PROVIDE SUPPLEMENTARY STEEL AS NECESSARY TO SUPPORT PIPES AND DUCTS FROM BUILDING STRUCTURE. THE ARCHITECT AND STRUCTURAL ENGINEER SHALL BE THE SOLE DETERMINANT AS TO PERMISSIBILITY OF HANGING NEW WORK FROM BUILDING STRUCTURE AND SLABS.

2. PIPING AND DUCTWORK PROVIDED UNDER THIS CONTRACT SHALL BE COORDINATED UNDER THIS CONTRACT WITH

WORK BEING PROVIDED BY OTHER TRADES.

3. FINAL LOCATION OF ALL CEILING DIFFUSERS, RETURN REGISTERS AND CEILING GRILLES SHALL BE AS SHOWN ON THE ARCHITECTURAL DRAWINGS. QUANTITIES OF THESE DEVICES SHALL BE PROVIDED AS SHOWN ON THE HVAC DRAWINGS.

ANY DISCREPANCIES BETWEEN THE HVAC DRAWINGS AND THE ARCHITECTURAL DRAWINGS SHALL BE BROUGHT TO THE

ATTENTION OF THE ARCHITECT FOR RESOLUTION PRIOR TO BID.

4. WHILE THE DRAWINGS SHALL BE ADHERED TO AS CLOSELY AS POSSIBLE, THE ARCHITECT'S RIGHT IS RESERVED TO VARY THE RUN AND SIZE OF DUCTS DURING THE PROGRESS OF THE WORK IF REQUIRED TO MEET CEILING HEIGHTS, TO MEET STRUCTURAL AND FIELD CONDITIONS. CONTRACTOR SHALL PROVIDE REDRAWING OF SHOP DRAWINGS AS NECESSARY TO ACCOMMODATE THE ARCHITECT'S REQUIREMENTS, AT NO ADDITIONAL COST TO THE OWNER. REFER TO

ARCHITECTURAL REFLECTED CEILING PLANS FOR REQUIRED CEILING HEIGHTS.

5. INSTALL ALL DUCTWORK IN STRICT ADHERENCE TO THE CEILING HEIGHTS INDICATED ON THE ARCHITECT'S DRAWINGS.

CONSULT WITH OTHER CONTRACTORS AND IN CONJUNCTION WITH THE OTHER CONTRACTORS, ESTABLISH THE

NECESSARY SPACE REQUIREMENTS FOR EACH TRADE.

6. THE SHEET METAL DUCTWORK SHALL, WHETHER INDICATED OR NOT, RISE AND/OR DROP AND/OR CHANGE IN SHAPE TO CLEAR ANY AND ALL OTHER DUCTWORK, CONDUITS, LIGHTING FIXTURES, PLUMBING AND HEATING/COOLING MAINS TO MAINTAIN THE DESIRED CEILING HEIGHTS AND TO PROVIDE ADEQUATE MAINTENANCE ROOM AND HEADROOM IN MECHANICAL EQUIPMENT ROOMS. THE DRAWINGS, IN GENERAL, DO NOT SHOW ALL RISES, DROPS AND DUCT

TRANSITIONS REQUIRED. THE DRAWINGS SHOW GENERAL ROUTING REQUIREMENTS ONLY.

7. ALL RECTANGULAR DUCTWORK, UNLESS OTHERWISE NOTED, SHALL BE BUILT FROM GALVANIZED SHEET STEEL AND THOROUGHLY BRACED AND STIFFENED. SEE SPECIFICATIONS FOR DUCTS REQUIRED TO BE FABRICATED OF ALUMINUM

AND STAINLESS STEEL. ALL EXHAUST DUCTWORK SHALL BE WELDED 316 STAINLESS STEEL.

8. ALL VALVES, REHEAT COIL, TERMINAL BOXES (VAV AND CV), DAMPERS AND OTHER EQUIPMENT LOCATED ABOVE THE CEILING, WHICH REQUIRE MAINTENANCE, SHALL BE LOCATED SO AS TO PERMIT MAINTENANCE. IN HIGH FLOOR TO FLOOR AREAS, THIS EQUIPMENT SHALL BE LOCATED AS LOW AS POSSIBLE IN THE CEILING CAVITY FOR EASIER ACCESS. LOCATE SUCH EQUIPMENT ABOVE ACCESSIBLE CEILINGS TO THE EXTENT POSSIBLE TO AVOID ACCESS DOORS IN THE CEILING.

9. PROVIDE ISOLATION VALVES WHERE TYING NEW PIPING INTO THE EXISTING SYSTEM. REFER TO THE VALVES SPECIFICATIONS FOR THE PROPER VALVE TYPE FOR THE SERVICE. REFER TO THE DRAWINGS FOR THE PIPE/VALVE SIZE.

IN ADDITION TO THE ISOLATION VALVES AT THE TIE-IN POINTS, ALSO PROVIDE A BALANCING VALVE ON THE SUPPLY SIDE FOR CHILLED WATER, CHILLED GLYCOL/BRINE, CONDENSER WATER AND HEATING/REHEAT HOT WATER SYSTEM TIE-INS.

10. ALL BIDDERS ARE REQUIRED TO REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL MEP/FP COMPONENTS FOR FULL INTEGRATION INTO ARCHITECTURAL DESIGN. BIDDERS ARE TO IMMEDIATELY CALL TO THE ARCHITECT'S ATTENTION ANY DISCREPANCIES IN QUANTITIES, TYPES AND SCOPE FOR ALL DISCIPLINES/TRADES.

11. SEE ARCHITECTURAL REFLECTED CEILING PLAN (RCP), DRAWINGS AND FLOOR PLANS FOR LOCATION OF ALL CEILING MOUNTED DEVICES. SEE ARCHITECTURAL DRAWINGS FOR LOCATION OF ALL WALL MOUNTED DEVICES.

12. SYMBOLS AND ABBREVIATIONS SHOWN ON THE DRAWINGS ARE FOR MECHANICAL DRAWINGS ONLY. SEE ARCHITECTURAL DRAWING AND OTHER TRADES DRAWINGS FOR THEIR RESPECTIVE SYMBOLS AND ABBREVIATIONS.

13. PRIOR TO PERFORMING ANY CORE DRILLING OR CUTTING OF EXISTING FLOOR OR ROOF SLAB, CONTRACTOR SHALL PERFORM A SCAN OF THE SLAB USING GROUND PENETRATING RADAR (GPR) TO CONFIRM THAT THERE ARE NO EXISTING

CONDUITS OR PIPES IN THE AREA OF CORE DRILL OR CUTTING OF THE SLAB.

14. REFER TO DWG AS101 AND SPECIFICATIONS FOR PHASING SEQUENCE OF DEMOLITION AND NEW WORK.

1. DEMOLITION OF HVAC ITEMS SHALL BE PERFORMED UNDER THE HVAC WORK.

2. LOCATION OF THE EXISTING DUCTWORK & PIPING AS SHOWN ON DRAWINGS IS APPROXIMATE.

3. PROVIDE TEMPORARY SUPPORTS WHERE REQUIRED.

4. DURING DEMOLITION, PROPERLY CAP AND PROTECT ALL DUCTWORK, EQUIPMENT, AND PIPING THAT WILL REMAIN IN OPERATION.

5. WHERE EXISTING INSULATION TO REMAIN IS DAMAGED BY THE REQUIREMENTS OF THE WORK, REPLACE ANY DAMAGED INSULATION TO

MATCH EXISTING.

6. DEMOLISH ALL EQUIPMENT AS INDICATED, FIXTURES AND/OR MISCELLANEOUS ARTICLES IN THEIR ENTIRETY INCLUDING AUXILIARY

EQUIPMENT, PIPING, WIRING, CONDUIT AND DUCTWORK.

7. MATERIALS RESULTING FROM THE DEMOLITION OPERATIONS SHALL NOT BE ALLOWED TO ACCUMULATE ON THE FLOORS AND ROOF SURFACES, EXTERIOR GRADE SURFACES OR OTHER PARTS OF THE PREMISES, AND SHALL BE PROMPTLY REMOVED AND DISPOSED OF

AWAY FROM THE PREMISES.

8. INCLUDE ALL DEMOLITION OF SYSTEMS AND COMPONENTS WHERE SYSTEMS SHALL BE REPLACED BY NEW WORK. REFER TO THE DRAWINGS AND SPECIFICATIONS FOR THE SCOPE OF NEW AND RECONNECTED WORK. THE INTENT OF THIS REQUIREMENT IS TO HAVE THE CONTRACTOR DISCONNECT, DEMOLISH AND REMOVE ALL EXPOSED AND CONCEALED WORK WHERE BEING REPLACED OR

CONNECTED TO THE NEW LAYOUTS.

9. COORDINATE ELECTRICAL POWER DISCONNECTION PRIOR TO DEMOLITION.

10. PROTECT ALL HVAC WORK AND WORK OF OTHER TRADES WHICH IS TO REMAIN, FROM DAMAGE DURING DEMOLITION.

11. ALL PIPING AND DUCTWORK TO REMAIN SHALL HAVE ENDS TERMINATED IN A NEAT MANNER READY FOR CONNECTION OF NEW WORK.

ALL EXPOSED ENDS OF PIPING AND DUCTWORK SHALL BE CAPPED. SCREWED PIPING SHALL END ON A SCREWED JOINT. FLANGED PIPE SHALL END WITH A FLANGED JOINT. WELDED PIPING SHALL BE MECHANICALLY CUT, CLEANED OF BURRS AND A CAP WELDED TO THE

PIPE. DUCTWORK SHALL BE CAPPED WITH SHEET METAL CONNECTED TO THE DUCT TO REMAIN.

12. REMOVAL OF EQUIPMENT, PIPING AND DUCTWORK SHALL INCLUDE ALL HANGERS & SUPPORT ASSOCIATED WITH THE EQUIPMENT, PIPING AND DUCTWORK TO BE REMOVED.

GENERAL NOTES:

GENERAL DEMOLITION NOTES:

NOTE:

SYMBOLS AND ABBREVIATIONS LISTED IN THE TABLES ABOVE ARE TYPICAL FOR HVAC AIR AND WATER DISTRIBUTION SYSTEMS. NOT ALL OF LISTED SYMBOLS OR ABBREVIATIONS WERE USED IN THIS PROJECT.

EF EXHAUST FAN

LAB EXHAUST FANLE

AIR HANDLERAH

FFU FAN FILTER UNIT

CONDENSATE PUMPCP

SG STEAM GENERATOR

INCHES OF WATER GAUGEIN. W.G.

T

H

DP DIFFERENTIAL PRESSURE SENSOR

AND DISPLAY

LPS

LPR

FFU-1

(400) FAN FILTER UNIT FFU-1, 400 CFM

INDUCTION UNITIU

PUMP CONDENSATEPC

SECONDARY CHILLED WATERSC

SECONDARY HOT WATERSH

SECONDARY RETURNSR

DRAIND

LOW PRESSURE CONDENSATELPC

TEMPERATURE AND HUMIDITY SENSORTH

SMOKE DETECTORSD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

MEP Consultant:

Project Director

20 Dec 2018Revisions: Date:

630-17-104

423 EAST 23RD STREET, NEW YORK, NY

RENOVATE ONCOLOGY PHARMACY

MICHAEL AVRAMIDES ARCHITECT

319 E 50TH STREET, STUDIO E

NEW YORK, NY 10022

T:917.855.8111

ONSULTING NGINEERS

KALLEN & LEMELSON, LLP

P: (212) 643-9898 F: (212) 643-2332

IGHTH VENUE, TH LOOR, EW ORK, 520 E

A 17 F N Y

C E

NY 10018

1-MH001

SYMBOLS, ABBREVIATIONS

AND GENERAL NOTES

J.O. N.R.

D

SR

SH

SC

IU IU IU IU

IU

IU

40x20 UP 40x18 DN

15x30 UP & DN

28x56 UP & DN

16x1012x8 x1

(210)

(210)

(270)

9x x6

(100)

(100)

(270)

8x

(100)

16x10

(100) 8x6

12"Ø 11"Ø

IU

D

SR

SH

SC

7" Ø

IU

10"Ø 10"Ø

D

SR

SH

SC

IU IU

8"Ø 7"Ø 7"Ø

1¼"

1"1¼"

1¼" 2"

1¼" 2"

42x24 UP

24x22 UP

24x20 UP

8" TR SITE FOR GE

FLUE

VAC. PUMP VENT UP TO ROOF

COND. PUMP VENT UP TO ROOF

CHEMO

COMPOUNDING

ISOLATOR

COMPOUNDING

ISOLATOR

EXHAUST FAN

VFD DRIVE

BCG HOOD

DISCONNECT AND

CAP DUCTWORK

DISCONNECT AND CAP

ALL DUCTWORK AND

PIPING TO IU (TYPICAL

FOR 6)

2"Ø MPR UP & DN

4"Ø MPS UP & DN

17x10

REMOVE RADIATORS AND CAP

STEAM AND CONDENSATE

RETURN CONNECTORS

CONDENSATE

RETURN

CONDENSATE

RETURN

STEAM

SUPPLY

STEAM

SUPPLY

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

MEP Consultant:

Project Director

20 Dec 2018Revisions: Date:

630-17-104

423 EAST 23RD STREET, NEW YORK, NY

RENOVATE ONCOLOGY PHARMACY

MICHAEL AVRAMIDES ARCHITECT

319 E 50TH STREET, STUDIO E

NEW YORK, NY 10022

T:917.855.8111

ONSULTING NGINEERS

KALLEN & LEMELSON, LLP

P: (212) 643-9898 F: (212) 643-2332

IGHTH VENUE, TH LOOR, EW ORK, 520 E

A 17 F N Y

C E

NY 10018

0 4' 8' 16'

SCALE: 1/8" = 1'-0"

12TH FLOOR DEMOLITION WORK HVAC PLAN

1-MD100J.O. N.R.

KEY MAP - BLDG 1 : 12TH FLOOR

12TH FLOOR DEMOLITION PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text

OFFICE R.M.

AutoCAD SHX Text 12090S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12091S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12092S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12093S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12095S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12082S

AutoCAD SHX Text

COPY

AutoCAD SHX Text 12080S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12079S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12077S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12075S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12073S

AutoCAD SHX Text

WAITING

AutoCAD SHX Text 12096S

AutoCAD SHX Text

RECEP

AutoCAD SHX Text 12097S

AutoCAD SHX Text

STAIR #3

AutoCAD SHX Text 12070S

AutoCAD SHX Text L.C.

AutoCAD SHX Text 12068S

AutoCAD SHX Text

SOILED

AutoCAD SHX Text

UTILITY

AutoCAD SHX Text 12062S

AutoCAD SHX Text

STOR

AutoCAD SHX Text 12064S

AutoCAD SHX Text

SUPPLY

AutoCAD SHX Text 12067S

AutoCAD SHX Text

TOILET

AutoCAD SHX Text 12069S

AutoCAD SHX Text

CHEMO AREA

AutoCAD SHX Text 12066S

AutoCAD SHX Text

CORR

AutoCAD SHX Text 12063S

AutoCAD SHX Text

CORR

AutoCAD SHX Text 12071S

AutoCAD SHX Text

CORR

AutoCAD SHX Text 12107S

AutoCAD SHX Text

ONCOLOGY

AutoCAD SHX Text

PHARMACY

AutoCAD SHX Text 12102S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12099S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12101S

AutoCAD SHX Text 12061S

AutoCAD SHX Text

TOILET

AutoCAD SHX Text 12059S

AutoCAD SHX Text

BATH

AutoCAD SHX Text 12058S

AutoCAD SHX Text 12057S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

12103AS

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12103S

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

NO SCALE

D

SR

SH

SC

40x20 UP 40x18 DN

15x30 UP & DN

28x56 UP & DN

16x1012x8

30x12

(210)

(210)

(270)

9x6

12x6

(100)

(100)

(270)

8x

(100)

8x612"Ø 11"Ø

D

SR

SH

SC

7"Ø

IU

IU

10"Ø 10"Ø

1¼"

2"

42x24 UP

2" MPR UP & DN

4" MPS UP & DN

17x10

DD

16x10

1" MPS

2" MPS

AC-60RF

MOTORIZED RELIEF AIR DAMPER

PLENUM 36x24x14

FC

20x10

FFU-4

(450) x1

1" PC

SR

SH

SC

PRV VALVE

8x18

12x8

CAV-12

IN VERTICAL

(800)

CR

(450)

CAV-1

(275)

FFU-2

(300)

12x10

FFU-3

(450)

FFU-1

(300)

FFU-7

(220)

5" Ø

FFU-6

(650)

CAV-6

(220)

8x8

CR

(75)

CAV-7

(310)

8x

18x8 DN 18x8 BR 6" AFF

CR

(350)

24x12

CAV-10

(75)

24x1022x8

12x8

8x68x6

20x8

24x14

5 1/8"Ø

12x6

7 1/8"Ø

12x10

8x

8x8

14x8

CAV-5

(650)

CAV-4

(450)

CAV-3

(450)

CAV-2

(300)

CAV-11

(350)

14"Ø14"Ø

DP

DP

18x8

FFU-5

(700)

12x8

8x612x8

20x10 12x8

12x8

8x

CAV-8

(310) FOR WORK IN THIS MER

AREA SEE DWG. MH-500

M

16x12 18x10

12x8

FC

18x8

CD

(275)

NEW INSULATED PANEL

IN WINDOW OPENING

NEW EXHAUST LOUVER IN

WINDOW OPENING BLANKED OFF

WITH INSULATED PANEL EXCEPT

FOR TOP 36x12

SEE ARCHITECTURAL DWG. FOR

DETAILS

VD

TH T

TH

TH

24x22 UP24x20 UP8" TR SITE FOR GE FLUE

VAC. PUMP VENT UP TO ROOF

COND. PUMP VENT UP TO ROOF

DP

NOTE:

1. CONTRACTOR SHALL RELOCATE ALL EXISTING PIPING AND CONDUITS AS REQUIRED TO INSTALL NEW WORK.

2. LINE OF PHASE 1 TEMPORARY CONSTRUCTION BARRIER SEE DWG. AD101.

3. REFER TO DWG. AS101 AND SPECIFICATIONS FOR PHASING SEQUENCE OF DEMOLITION AND NEW WORK.

12x8

12x8

DP

12x8 DN 12x8 BR 6" AFF

18x8 DN 18x8 BR 6" AFF

12x8

8x8

VD

8x8CAV-9 (450)

14"Ø

12x8

12" Ø ID

14" Ø OD 316 STAINLESS STEEL

MANUFACTURED EXHAUST DUCT

UP TO EF-19S FAN ON ROOF

12" Ø ID

14" Ø OD 316 STAINLESS STEEL

MANUFACTURED EXHAUST DUCT

UP TO EF-20S FAN ON ROOF

12" Ø ID

14" Ø OD 316 STAINLESS STEEL

MANUFACTURED EXHAUST DUCT

UP TO EF-20S FAN ON ROOF

CORRIDOR

CHEMO BUFER ROOM

STERILE COMPOUNDING

ROOM

OFFICE

ANTE ROOM

(171 SQ. FT.)

NEGATIVE TO CORRIDOR

NEGATIVE PRESSURE

-.01"

(123 SQ. FT.), 36.6 AC/HR

POSITIVE PRESSURE

+.02" W.G.

(185 SQ. FT.), 35.3 AC/HR

NEGATIVE PRESSURE

-0.02" W.G.

(192 SQ. FT.), 62.5 AC/HR

POSITIVE PRESSURE

O.02" W.G.

EXHAUST AIR

(1070 CFM)

SUPPLY AIR

(870 CFM)

TRANSFER AIR

(200 CFM)

SUPPLY AIR

(300 CFM)

FFU

RECIRCULATION

AIR (300 CFM)

TRANSFER AIR

(300 CFM)

TRANSFER AIR

(200 CFM)

RETURN AIR

(800 CFM)

SUPPLY AIR

(900 CFM)

TRANSFER AIR

(50 CFM)

SUPPLY AIR

(275 CFM)

RETURN AIR

(350 CFM)

DISPENSING ROOM

(45 SQ. FT.)

NEGATIVE PRESSURE

-.01" W.G.

EXHAUST AIR

(75 CFM)

TRANSFER AIR

(75 CFM)

FFU

RECIRCULATION

AIR (700 CFM)

ISO 7

CLEAN ROOM

ISO 7

CLEAN ROOM

ISO 7

CLEAN ROOM

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

MEP Consultant:

Project Director

20 Dec 2018Revisions: Date:

630-17-104

423 EAST 23RD STREET, NEW YORK, NY

RENOVATE ONCOLOGY PHARMACY

MICHAEL AVRAMIDES ARCHITECT

319 E 50TH STREET, STUDIO E

NEW YORK, NY 10022

T:917.855.8111

ONSULTING NGINEERS

KALLEN & LEMELSON, LLP

P: (212) 643-9898 F: (212) 643-2332

IGHTH VENUE, TH LOOR, EW ORK, 520 E

A 17 F

N Y

C E

NY 10018

0 2' 4' 8'

SCALE: 1/4" = 1'-0"

12TH FLOOR NEW WORK HVAC PART PLAN AND

PHARMACY AIRFLOW PRESSURE DIAGRAM

1-MH101

J.O. N.R.

KEY MAP - BLDG 1 : 12TH FLOOR

12TH FLOOR NEW WORK HVAC PART PLAN

PHARMACY AIRFLOW AND PRESSURE DIAGRAM

AutoCAD SHX Text W

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text T

AutoCAD SHX Text

OFFICE R.M.

AutoCAD SHX Text 12090S

AutoCAD SHX Text

OFFICE R.M.

AutoCAD SHX Text 12089S

AutoCAD SHX Text

OFFICE R.M.

AutoCAD SHX Text 12088S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12086S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12087S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12082S

AutoCAD SHX Text

COPY

AutoCAD SHX Text 12080S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12079S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12077S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12075S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12073S

AutoCAD SHX Text

STAIR #3

AutoCAD SHX Text 12070S

AutoCAD SHX Text L.C.

AutoCAD SHX Text 12068S

AutoCAD SHX Text

SUPPLY

AutoCAD SHX Text 12067S

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text 12095S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12093S

AutoCAD SHX Text

CHANGING

AutoCAD SHX Text

12093BS

AutoCAD SHX Text

DISPENSING

AutoCAD SHX Text

12093AS

AutoCAD SHX Text

ANTEROOM

AutoCAD SHX Text

12093CS

AutoCAD SHX Text

STERILE

AutoCAD SHX Text

COMPOUNDING

AutoCAD SHX Text

12093DS

AutoCAD SHX Text

CHEMO

AutoCAD SHX Text

BUFFER

AutoCAD SHX Text

12093ES

AutoCAD SHX Text W

AutoCAD SHX Text X

AutoCAD SHX Text W

AutoCAD SHX Text V

AutoCAD SHX Text U

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

NO SCALE

NTS

CHEMO EF-19S

ON 12" HIGH CURB

NOTE:

SCAFFOLDING AND SIDEWALK SHED AND BRIDGING ARE REQUIRED

FOR INSTALLATION OF THE EXTERIOR CONDUITS AND DUCTWORK.

VFD IN NEMA 3R

ENCLOSURE

14" EXHAUST DUCT

TO FAN ON ROOF

FENCE

14" EXHAUST DUCT

TO FAN ON ROOF

CHEMO EF-20S

ON 12" HIGH CURB

VFD IN NEMA 3R

ENCLOSURE

12" Ø ID

14" Ø OD 316 STAINLESS STEEL

MANUFACTURED EXHAUST DUCT

14"Ø

14"Ø

I" GALVANIZED

STEEL CONDUIT

STAINLESS STEEL

CONDUIT STRAP

SUPPORT TO WALL

EVERY 10 FT.

(TYPICAL)

134.00

BYPASS AIR PLENUM

14" EXHAUST DUCT

TO FAN ON ROOF

12" ROOF CURB

CHEMO EF-19S

FENCE

ROOF

14"Ø

14"Ø

DUCT SUPPORTS A MINIMUM

OF EVERY 6 FT.

14"Ø

12" Ø ID

14" Ø OD 316 STAINLESS STEEL

MANUFACTURED EXHAUST DUCT

134.00

BYPASS AIR

PLENUM

CHEMO EF-20S

12" ROOF

CURB

14" EXHAUST DUCT

TO FAN ON ROOF

14"Ø

14"Ø

NEW INSULATED PANEL

IN WINDOW OPENING

DUCT SUPPORTS A MINIMUM

OF EVERY 6 FT.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

MEP Consultant:

Project Director

20 Dec 2018Revisions: Date:

630-17-104

423 EAST 23RD STREET, NEW YORK, NY

RENOVATE ONCOLOGY PHARMACY

MICHAEL AVRAMIDES ARCHITECT

319 E 50TH STREET, STUDIO E

NEW YORK, NY 10022

T:917.855.8111

ONSULTING NGINEERS

KALLEN & LEMELSON, LLP

P: (212) 643-9898 F: (212) 643-2332

IGHTH VENUE, TH LOOR, EW ORK, 520 E

A 17 F N Y

C E

NY 10018

ROOF HVAC PART PLAN & SOUTH ELEVATION

1-MH102J.O. N.R.

0 1' 2' 4'

SCALE: 1/2" = 1'-0"

0 2' 4' 8'

SCALE: 1/4" = 1'-0"

SOUTH ELEVATION

ROOF PART PLAN

AutoCAD SHX Text

SIDE INLET

AutoCAD SHX Text

SIDE INLET

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

18TH FL

AutoCAD SHX Text

17TH FL

AutoCAD SHX Text

16TH FL

AutoCAD SHX Text

15TH FL

AutoCAD SHX Text

14TH FL

AutoCAD SHX Text

13TH FL

AutoCAD SHX Text

12TH FL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

14" PRIMARY CHILLED WATER

SUPPLY & RETURN

D

SR

SH

SC

40x20 UP 40x18 DN

15x30 UP & DN

28x56 UP & DN

16x1012x8 x1

(210)

(210)

(270)

9x x6

(100)

(100)

(270)

8x

(100)

16x10 8x612"Ø

11"Ø

D

SR

SH

SC

7" Ø

IU

IU

10"Ø 10"Ø

D

SR

SH

SC

IU IU

8"Ø 7"Ø 7"Ø

1¼"

1" 1¼"1¼"

2"

1¼" 2"

42x24 UP

24x22 UP

24x20 UP

8" TR SITE FOR GE FLUE

VAC. PUMP VENT UP TO ROOF

COND. PUMP VENT UP TO ROOF

17x10

DD

112"Ø CHWS&R

FOR NEW WORK IN THIS AREA

REFER TO DRAWING MH-101

CAV-1

(275)

CAV-6

(190)

CAV-5

(650)

CAV-4

(475) CAV-2

(200)

1 1/4"

HWS&R

1"

1"

3/4"

1"

HWS&R 1"

3/4"

3/4"

HWS&R

2"Ø MPR UP & DN

4"Ø MPS UP & DN

1"Ø MPS

112"Ø MPS

1"Ø PC

PRV VALVE

1"Ø PC

1"

FOR WORK IN THIS MER

AREA SEE DWG. MH-500

DATA

12109C

CAV-3

(475)

0 4' 8' 16'

SCALE: 1/8" = 1'-0"

12TH FLOOR NEW WORK PIPING PLAN

1-MP103

J.O. N.R.

KEY MAP - BLDG 1 : 12TH FLOOR

12TH FLOOR NEW WORK PIPING PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

MEP Consultant:

Project Director

20 Dec 2018Revisions: Date:

630-17-104

423 EAST 23RD STREET, NEW YORK, NY

RENOVATE ONCOLOGY PHARMACY

MICHAEL AVRAMIDES ARCHITECT

319 E 50TH STREET, STUDIO E

NEW YORK, NY 10022

T:917.855.8111

ONSULTING NGINEERS

KALLEN & LEMELSON, LLP

P: (212) 643-9898 F: (212) 643-2332

IGHTH VENUE, TH LOOR, EW ORK, 520 E

A 17 F

N Y

C E

NY 10018

AutoCAD SHX Text

AutoCAD SHX Text X

AutoCAD SHX Text W

AutoCAD SHX Text V

AutoCAD SHX Text U

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text O

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE R.M.

AutoCAD SHX Text 12090S

AutoCAD SHX Text

OFFICE R.M.

AutoCAD SHX Text 12089S

AutoCAD SHX Text

OFFICE R.M.

AutoCAD SHX Text 12088S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12086S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12087S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12082S

AutoCAD SHX Text

COPY

AutoCAD SHX Text 12080S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12079S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12077S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12075S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12073S

AutoCAD SHX Text

WAITING

AutoCAD SHX Text 12096S

AutoCAD SHX Text

RECEP

AutoCAD SHX Text 12097S

AutoCAD SHX Text

STAIR #3

AutoCAD SHX Text 12070S

AutoCAD SHX Text L.C.

AutoCAD SHX Text 12068S

AutoCAD SHX Text

SOILED

AutoCAD SHX Text

UTILITY

AutoCAD SHX Text 12062S

AutoCAD SHX Text

STOR

AutoCAD SHX Text 12064S

AutoCAD SHX Text

SUPPLY

AutoCAD SHX Text 12067S

AutoCAD SHX Text

TOILET

AutoCAD SHX Text 12069S

AutoCAD SHX Text

CHEMO AREA

AutoCAD SHX Text 12066S

AutoCAD SHX Text

CORR

AutoCAD SHX Text 12063S

AutoCAD SHX Text

CORR

AutoCAD SHX Text 12071S

AutoCAD SHX Text

CORR

AutoCAD SHX Text 12107S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12099S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12101S

AutoCAD SHX Text 12061S

AutoCAD SHX Text

TOILET

AutoCAD SHX Text 12059S

AutoCAD SHX Text

BATH

AutoCAD SHX Text 12058S

AutoCAD SHX Text 12057S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

12103AS

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12103S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12105S

AutoCAD SHX Text

CORR

AutoCAD SHX Text 12113S

AutoCAD SHX Text 12109C

AutoCAD SHX Text 12111C

AutoCAD SHX Text

LAB

AutoCAD SHX Text

12111AC

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12112C

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12113C

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12114N

AutoCAD SHX Text

CORR

AutoCAD SHX Text 12161N

AutoCAD SHX Text 12160N

AutoCAD SHX Text

CORR

AutoCAD SHX Text 12118C

AutoCAD SHX Text

CORR

AutoCAD SHX Text 12118N

AutoCAD SHX Text

SERVICE

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text 12114C

AutoCAD SHX Text

CORR

AutoCAD SHX Text 12055C

AutoCAD SHX Text

ELEV

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text 12000C

AutoCAD SHX Text

CORR

AutoCAD SHX Text 12054W

AutoCAD SHX Text

TOILET

AutoCAD SHX Text 12053C

AutoCAD SHX Text

TOILET

AutoCAD SHX Text 12052C

AutoCAD SHX Text

JC

AutoCAD SHX Text 12049C

AutoCAD SHX Text

TELE

AutoCAD SHX Text 12050C

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12048C

AutoCAD SHX Text

WAITING

AutoCAD SHX Text

12048AC

AutoCAD SHX Text

RECEP

AutoCAD SHX Text

12048BC

AutoCAD SHX Text

STAIR #1

AutoCAD SHX Text 12002C

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12045W

AutoCAD SHX Text

EXAM

AutoCAD SHX Text 12000W

AutoCAD SHX Text

CORR

AutoCAD SHX Text 12042W

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text 12095S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12102S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 12093S

AutoCAD SHX Text

CHANGING

AutoCAD SHX Text

12093BS

AutoCAD SHX Text

DISPENSING

AutoCAD SHX Text

12093AS

AutoCAD SHX Text

ANTEROOM

AutoCAD SHX Text

12093CS

AutoCAD SHX Text

STERILE

AutoCAD SHX Text

COMPOUNDING

AutoCAD SHX Text

12093DS

AutoCAD SHX Text

CHEMO

AutoCAD SHX Text

BUFFER

AutoCAD SHX Text

12093ES

AutoCAD SHX Text

NORTH

NO SCALE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

MEP Consultant:

Project Director

20 Dec 2018Revisions: Date:

630-17-104

423 EAST 23RD STREET, NEW YORK, NY

RENOVATE ONCOLOGY PHARMACY

MICHAEL AVRAMIDES ARCHITECT

319 E 50TH STREET, STUDIO E

NEW YORK, NY 10022

T:917.855.8111

ONSULTING NGINEERS

KALLEN & LEMELSON, LLP

P: (212) 643-9898 F: (212) 643-2332

IGHTH VENUE, TH LOOR, EW ORK, 520 E

A 17 F N Y

C E

NY 10018

HVAC SCHEDULES 1

1-MH401

J.O. N.R.

HVAC SCHEDULES 2

1-MH402

J.O. N.R.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

MEP Consultant:

Project Director

20 Dec 2018Revisions: Date:

630-17-104

423 EAST 23RD STREET, NEW YORK, NY

RENOVATE ONCOLOGY PHARMACY

MICHAEL AVRAMIDES ARCHITECT

319 E 50TH STREET, STUDIO E

NEW YORK, NY 10022

T:917.855.8111

ONSULTING NGINEERS

KALLEN & LEMELSON, LLP

P: (212) 643-9898 F: (212) 643-2332

IGHTH VENUE, TH LOOR, EW ORK, 520 E

A 17 F N Y

C E

NY 10018

6" HIGH CONCRETE

CURB PAINTED SAFETY YELLOW,

SEE A-5-200 FOR DETAILS

AC-60

NEW AIR CONDITIONING UNIT AC-60 TO BE INSTALLED

1"Ø MPS

1"Ø PC

2"Ø COPPER ATMOSPHERIC

STEAM TO HUMIDIFIER

STEAM EXCHANGE

STEAM GENERATOR,

WALL MOUNTED 4'-6" AFF

20x10

20x10 DN TO UNIT W/FC

(2250)

CONDENSATE PUMP CP-1

ON 4" CONCRETE PAD

PAINTED YELLOW

SD

PRV VALVE ASSEMBLY

(10"-0" LONG ABOVE)

1" Ø RELIEF VENT

OUTSIDE

1/2"Ø LPC

TO CP-1

1"Ø LPC

1/2"Ø LPS

40" x 52" x 32" D PLENUM

1" PC

1"Ø DRAIN

1 1/2"Ø LPS

1"Ø DRAIN

1"Ø CW

44"X12"X55"

PLENUM

8X24 AD

1"Ø LPS

1"Ø LPS

INTEGRAL FACE AND

BYPASS STEAM COIL

FOR CONTINUATION

SEE DWG. MH-101

CHILLED WATER COIL

HUMIDIFIER SECTION

1"Ø DRAIN

NEW LOUVER IN WINDOW OPENING BLANKED OFF

WITH INSULATED PANEL EXCEPT BOTTOM 34x24.

SEE ARCHITECTURAL DWG. FOR DETAILS

1" LPC

TO CP-1

1 1/2"

CHWS&R

2 VFDS (STACKED)

FOR CHEMO EF19S

EXHAUST FANS ON ROOF

BMS CONTROL PANEL

VF

D

ELECTRICAL PANEL

BM

S

FAN

FILTERS

24x12 DN TO UNIT W/FC

11'-2"

2'

9'-0"

10'-6"

10'

12" w x 55" H x 44" D PLENUM

20x10 DN TO UNIT W/FC

52" x 32" x 40" D PLENUM

6" HIGH CONCRETE CURB

PAINTED SAFETY YELLOW, SEE

ARCHITECTURAL FOR DETAILS

8"x24"ACCESS DOOR

MIXING PLENUM

RA DAMPER

OA DAMPER

FILTERS

INTERNAL FACE & BYPASS STEAM COIL

24x36 OAI LOUVER IN

THE WINDOW OPENING

CHILLED WATER COILHUMIDIFIER SECTION

FAN

NEW LOUVER IN WINDOW OPENING BLANKED OFF

WITH INSULATED PANEL EXCEPT BOTTOM 24x36

ACCESS

SD

x

OA AIRFLOW SENSOR

STEAM EXCHANGE

STEAM GENERATOR,

WALL MOUNTED 4'-6" AFF

CONDENSATE PUMP CP-1

ON 4" CONCRETE PAD

PAINTED YELLOW

CHILLED WATER COIL

AC-60

(2250)

VF

D

BM

S

INTEGRAL FACE AND

BYPASS STEAM COIL

HUMIDIFIER SECTION

2 VFDS (STACKED)

FOR CHEMO EF19S

EXHAUST FANS ON ROOF

BMS CONTROL PANEL

ELECTRICAL PANEL

FAN

FILTERS

12TH FLOOR NEW WORK

HVAC MER PART PLAN AND SECTION

1-MH500

J.O. N.R.

0 1' 2' 4'

SCALE: 1/2" = 1'-0"

12TH FLOOR NEW WORK HVAC MER PART PLAN

0 1' 2' 4'

SCALE: 1/2" = 1'-0"

12TH FLOOR NEW WORK HVAC MER SECTION A-A

0 1' 2' 4'

SCALE: 1/2" = 1'-0"

MER EQUIPMENT ACCESS PART PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

MEP Consultant:

Project Director

20 Dec 2018Revisions: Date:

630-17-104

423 EAST 23RD STREET, NEW YORK, NY

RENOVATE ONCOLOGY PHARMACY

MICHAEL AVRAMIDES ARCHITECT

319 E 50TH STREET, STUDIO E

NEW YORK, NY 10022

T:917.855.8111

ONSULTING NGINEERS

KALLEN & LEMELSON, LLP

P: (212) 643-9898 F: (212) 643-2332

IGHTH VENUE, TH LOOR, EW ORK, 520 E

A 17 F

N Y

C E

NY 10018

AutoCAD SHX Text "A"

AutoCAD SHX Text "A"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

STEAM SUPPLY

SHUT-OFF VALVE

CONDENSATE RETURN

GATE VALVE (TYP.)

CHECK VALVE

STEAM TRAP TEST TEE

FLOAT & THERMOSTATIC TRAP

(TWICE COIL CAPACITY)

Y-STRAINER W/BLOW-OFF VALVE

CAP

6" MINIMUM

FULL SIZE COIL TAPPING

UNION OR FLANGE

(AS REQUIRED TYP.)

VACUUM BREAKER

STEAM COIL

CONTROL

VALVE

BYPASS

LINE

GLOBE VALVE

HVAC DETAILS 1

1-MH701

J.O. N.R.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

MEP Consultant:

Project Director

20 Dec 2018Revisions: Date:

630-17-104

423 EAST 23RD STREET, NEW YORK, NY

RENOVATE ONCOLOGY PHARMACY

MICHAEL AVRAMIDES ARCHITECT

319 E 50TH STREET, STUDIO E

NEW YORK, NY 10022

T:917.855.8111

ONSULTING NGINEERS

KALLEN & LEMELSON, LLP

P: (212) 643-9898 F: (212) 643-2332

IGHTH VENUE, TH LOOR, EW ORK, 520 E

A 17 F N Y

C E

NY 10018

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

DUCTWORK RADIUS ELBOWS

AutoCAD SHX Text

VANE

AutoCAD SHX Text

VANE

AutoCAD SHX Text

NOTE: 1. 2.

AutoCAD SHX Text THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND. ALL STANDARD RADIUS ELBOWS CAN BE SUBSTITUTED WITH SHORT RADIUS ELBOWS. ALL SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES SHALL BE CONSTRUCTED, SUPPORTED AND FASTENED AS RECOMMENDED BY SMACNA.

AutoCAD SHX Text

R SHALL EQUAL OR BE GREATER THAN W.

AutoCAD SHX Text

R SHALL EQUAL OR BE GREATER THAN 1/3W.

AutoCAD SHX Text R

AutoCAD SHX Text

R SHALL EQUAL OR BE GREATER THAN 1/6W.

AutoCAD SHX Text

STANDARD RADIUS OR LONG RADIUS ELBOW

AutoCAD SHX Text

SHORT RADIUS ELBOW WITH ONE VANE

AutoCAD SHX Text

SHORT RADIUS ELBOW WITH TWO VANES

AutoCAD SHX Text R

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

DUCTWORK SQUARE VANE ELBOWS

AutoCAD SHX Text

NOTE: 1. 2. 3. 4.

AutoCAD SHX Text ALL VANE ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY SMACNA. WHEN W1 DOES NOT EQUAL W2, VANE SHALL BE SINGLE THICKNESS VANE TYPE REGARDLESS OF W DIMENSION. ALL SINGLE THICKNESS VANES SHALL HAVE A 2" [50mm] RADIUS, 1 1/2" [40mm] MAXIMUM SPACE BETWEEN VANES AND A 3/4" [20mm] TRAILING EDGE. WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" [500mm] VANES SHALL BE DOUBLE VANE TYPE.

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

SUPPLY DUCT TAKEOFF - AIR TERMINAL UNIT

AutoCAD SHX Text

RIGID DUCT TO AIR TERMINAL UNIT.

AutoCAD SHX Text

ROUND SHEET METAL DUCT.

AutoCAD SHX Text

MAIN SUPPLY

AutoCAD SHX Text

PLAN VIEW

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

SUPPLY DUCTWORK TAKE-OFFS

AutoCAD SHX Text

DESIGNER'S NOTES:

AutoCAD SHX Text

1. THE SUPPLY REGISTER TAKE-OFF MAY BE USED FOR UP UP TO 25% OF THE MAIN THE SUPPLY REGISTER TAKE-OFF MAY BE USED FOR UP UP TO 25% OF THE MAIN DUCT CFM. THE BRANCH DUCT TAKE-OFF MAY BE USED FOR UP TO 15% OF THE MAIN DUCT CFM ANYTIME AND UP TO 40% WHEN THE MAIN DUCT VELOCITY IS 1000 FPM [5.1 M/S] OR LESS. THE AIR SPLIT DUCT TAKE-OFF SHALL BE USED IN ALL OTHER CASES AND MAY BE USED AT ANYTIME. 2. SHOW ALL VOLUME DAMPERS ON FLOOR PLANS.SHOW ALL VOLUME DAMPERS ON FLOOR PLANS.

AutoCAD SHX Text

AIR SPLIT DUCT TAKE-OFF PLAN VIEW

AutoCAD SHX Text

BRANCH DUCT TAKE-OFF PLAN VIEW

AutoCAD SHX Text

SUPPLY REGISTER TAKE-OFF PLAN VIEW

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

SUPPLY REGISTER OR BRANCH DUCT

AutoCAD SHX Text

TURNING VANES

AutoCAD SHX Text

MAIN SUPPLY DUCT

AutoCAD SHX Text

SEE FLOOR PLAN FOR SPLIT DIMENSION

AutoCAD SHX Text

VOLUME DAMPER

AutoCAD SHX Text

VOLUME DAMPER

AutoCAD SHX Text

ADJUSTABLE METAL ROD OR LINKAGE

AutoCAD SHX Text

TOP REGISTER

AutoCAD SHX Text

MAIN SUPPLY DUCT

AutoCAD SHX Text VOLUME EXTRACTOR; ADJUSTABLE FROM FULLY CLOSED POSITION TO CFM NOTED ON FLOOR PLANS

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text 1/4 W OR 4" [100mm] MIN.

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

MAIN SUPPLY DUCT

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

VOLUME DAMPER

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

EXHAUST OR RETURN BRANCH DUCTWORK

AutoCAD SHX Text

MAIN EXHAUST OR RETURN

AutoCAD SHX Text

%%UPLAN VIEW

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

PROVIDE VOLUME DAMPER AT EACH BRANCH DUCT

AutoCAD SHX Text 1/4W OR 4" [100mm] MIN.

AutoCAD SHX Text

BRANCH DUCT

AutoCAD SHX Text

VD

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

VOLUME DAMPER DETAIL

AutoCAD SHX Text

NOTE: 1. 2.

AutoCAD SHX Text DELETE INSULATION STAND-OFF ON DUCTWORK WITHOUT EXTERIOR INSULATION. DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR FOR MULTI-BLADE DAMPERS & ROUND DAMPERS.

AutoCAD SHX Text

INSULATION SEE SPECIFICATION

AutoCAD SHX Text

DAMPER BLADE

AutoCAD SHX Text 1/8" [6mm] CLEARANCE ALL AROUND

AutoCAD SHX Text

OUTSIDE END BEARING

AutoCAD SHX Text

INSIDE END BEARING

AutoCAD SHX Text

HANDLE WITH LOCKING QUADRANT

AutoCAD SHX Text

INSULATION STAND-OFF

AutoCAD SHX Text 1/2" [15mm] ROUND ROD PIN

AutoCAD SHX Text

DUCT

AutoCAD SHX Text

STIFFEN BLADE AS REQUIRED

AutoCAD SHX Text

SIDE ELEVATION

AutoCAD SHX Text

SECTION

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

(WITH EQUIPMENT MOUNTED IN DUCT)

AutoCAD SHX Text

DUCTWORK TRANSITIONS

AutoCAD SHX Text

NOTE: UNLESS OTHERWISE INDICATED ON PLANS, MAXIMUM ANGLES SHOWN SHALL APPLY.

AutoCAD SHX Text

MAX.

AutoCAD SHX Text

MAX.

AutoCAD SHX Text

EQUIPMENT

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

TYPICAL DUCTWORK TRANSITION PLAN OR SIDE VIEW

AutoCAD SHX Text

TYPICAL DUCTWORK TRANSITION WITH EQUIPMENT MOUNTED IN DUCT PLAN OR SIDE VIEW

AutoCAD SHX Text

MAX.

AutoCAD SHX Text

MAX.

AutoCAD SHX Text

MAX.

AutoCAD SHX Text

MAX.

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

DUCT CONNECTIONS - AIR TERMINAL UNITS

AutoCAD SHX Text

NOTE: 1. 2. 3. 4. 5. 6.

AutoCAD SHX Text RIGID STRAIGHT TERMINAL UNIT INLET LENGTH SHALL BE A MINIMUM OF 3 TIMES THE DIAMETER OF INLET A FLEXIBLE AIR DUCT CONNECTOR IS NOT MANDATORY FOR INLET TO THIS BOX, BUT ALLOWED TO ACCOMMODATE MINOR OFFSETS. MAXIMUM LENGTH 3'-0" [900mm]. A BRANCH DUCT SERVING AN INDIVIDUAL BOX MAY BE THE SAME SIZE AS THE BOX INLET, PROVIDED THE EQUIVALENT LENGTH OF THE BRANCH DUCT, AS SHOWN, DOES NOT EXCEED 10 FEET (3 METERS). FOR LONGER LENGTHS, INCREASE THE DUCT SIZE AND PROVIDE A DUCT TRANSITION TO MAINTAIN THE DUCT STATIC PRESSURE DROP AT OR BELOW 0.2"/100' [1.64Pa/m]. FLEXIBLE AIR DUCT CONNECTORS, WHEN USED FROM TERMINAL UNIT SUPPLY AIR DUCT TO DIFFUSER, SHALL NOT EXCEED 5'-0" [1500mm]. USE RIGID ELBOWS FOR CHANGE OF DIRECTION GREATER THAN 45°.COMPONENT ARRANGEMENT MAY VARY BY MANUFACTURER. PROVIDE INSULATION W/VAPOR BARRIER FOR CONNECTING DUCT SECTIONS. USE OF THE FLEXIBLE AIR DUCT CONNECTORS ARE NOT PERMITTED FOR THE DEDICATED AHU SERVING THE SURGICAL SUITE.

AutoCAD SHX Text

AIR TERMINAL UNIT (CV OR VAV)

AutoCAD SHX Text

REHEAT COIL

AutoCAD SHX Text

SOUND ATTENUATOR SEE EQUIPMENT SCHEDULE

AutoCAD SHX Text

FLEXIBLE AIR DUCT CONNECTOR. SEE DETAIL

AutoCAD SHX Text

DIFFUSER (TYP.)

AutoCAD SHX Text

SEE SPECIFICATIONS FOR CLAMPS AND SEALANT (TYP.)

AutoCAD SHX Text

SEE NOTE 5

AutoCAD SHX Text

DESIGNER'S NOTE: 1.INDICATE SOUND ATTENUATOR AS REQUIRED BY ACOUSTICAL ANALYSIS

AutoCAD SHX Text

AutoCAD SHX Text

AIR HANDLING UNIT DRAIN TRAP DETAIL

AutoCAD SHX Text

NTS

AutoCAD SHX Text

DRAW THRU

AutoCAD SHX Text

BLOW THRU

AutoCAD SHX Text 2" [50mm] PLUS X

AutoCAD SHX Text 1" [25mm] MINIMUM

AutoCAD SHX Text X

AutoCAD SHX Text 2X

AutoCAD SHX Text

UNIT TYPE

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text

WHERE X = STATIC PRESSURE IN PAN

AutoCAD SHX Text DRAIN LINE SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN PIPING SHALL BE RIGID COPPER TYPE L OR TYPE M UNLESS NOTE BELOW IS MET

AutoCAD SHX Text

PITCH DOWN TOWARD DRAIN

AutoCAD SHX Text

CLEAN OUT

AutoCAD SHX Text

FLOOR SINK

AutoCAD SHX Text

DRAIN PAN

AutoCAD SHX Text NOTE: 1. CPVC PIPE MAY BE USED ONLY IF APPROVED BY 1. CPVC PIPE MAY BE USED ONLY IF APPROVED BY LOCAL VA AND IS INDOORS AND DOES NOT PASS THROUGH RATED BARRIERS. 2. DIELECTRIC FITTING TO BE USED WHEN TWO DISSIMILAR METALS ARE TO BE CONNECTED.

AutoCAD SHX Text [25mm]

AutoCAD SHX Text

DIELECTRIC FITTING

AutoCAD SHX Text

STEAM COIL PIPING DETAIL

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

TYPICAL MANUAL AIR VENT

AutoCAD SHX Text

TYPICAL CHILLED AND HOT WATER PIPING DRAIN VALVE CONNECTIONS

AutoCAD SHX Text

ELEVATION THREADED PIPING

AutoCAD SHX Text

ELEVATION WELDED PIPING

AutoCAD SHX Text

TYPICAL WATER PIPING

AutoCAD SHX Text

REDUCER, IF REQUIRED

AutoCAD SHX Text 3/4" [20mm] BALL VALVE

AutoCAD SHX Text ADAPTER TO 3/4" [20mm] HOSE THREAD-PROVIDE HOSE CAP NUT

AutoCAD SHX Text NOTES: 1. DRAIN ALL LOW POINTS AS INDICATED ABOVE. 2. WHERE SCALE POCKETS ARE SHOWN ON PIPE RISER DIAGRAMS AND/OR PLANS LOCATE DRAIN AT BOTTOM OF SCALE POCKET.

AutoCAD SHX Text

AIR VENT

AutoCAD SHX Text 1/2" [15mm] BALL VALVE

AutoCAD SHX Text 1/4" [8mm] COPPER TUBING

AutoCAD SHX Text 1/2" [15mm] x 4" [100mm] NIPPLE

AutoCAD SHX Text

CIRCULATING WATER PIPING

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text NOTES: 1. VENT ALL HIGH POINTS INDICATED ABOVE. 2. IF AUTOMATIC AIR VENTS ARE USED, PIPE DISCHARGE TO DRAIN.

AutoCAD SHX Text

DRAIN VALVE AND AIR VENT CONNECTIONS (HYDRONIC SYSTEMS)

AutoCAD SHX Text

MV

AutoCAD SHX Text

OR

AutoCAD SHX Text

AV

AutoCAD SHX Text

RECEIVER

AutoCAD SHX Text

WATER LEVEL GAUGE

AutoCAD SHX Text

THERMOMETER

AutoCAD SHX Text

AutoCAD SHX Text

CONDENSATE PUMPS - PIPING CONNECTIONS

AutoCAD SHX Text

NTS

AutoCAD SHX Text

LPR

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text 20mm [3/4"] DRAIN, DISCHARGE INTO NEAREST FLOOR DRAIN, NC.

AutoCAD SHX Text

THERMOMETER

AutoCAD SHX Text

SCHEDULE 80 PUMP DISCHARGE TO PLANT

AutoCAD SHX Text

VENT

AutoCAD SHX Text

FLUSHING CONNECTION

AutoCAD SHX Text

SCHEDULE 80 STEEL PIPE

AutoCAD SHX Text

SCHEDULE 80 STEEL PIPE

100mm [4"] THICK CONCRETE HOUSEKEEPING PAD PAINT SAFETY YELLOW

HVAC DETAILS 2

1-MH702

J.O. N.R.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

MEP Consultant:

Project Director

20 Dec 2018Revisions: Date:

630-17-104

423 EAST 23RD STREET, NEW YORK, NY

RENOVATE ONCOLOGY PHARMACY

MICHAEL AVRAMIDES ARCHITECT

319 E 50TH STREET, STUDIO E

NEW YORK, NY 10022

T:917.855.8111

ONSULTING NGINEERS

KALLEN & LEMELSON, LLP

P: (212) 643-9898 F: (212) 643-2332

IGHTH VENUE, TH LOOR, EW ORK, 520 E

A 17 F N Y

C E

NY 10018

AutoCAD SHX Text

WATER COILS - PIPING CONNECTIONS

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

%%USINGLE COIL

AutoCAD SHX Text

WATER COIL

AutoCAD SHX Text

AIR VENT WHEN COIL IS NOT SELF-VENTING

AutoCAD SHX Text

DRAIN WHEN COIL IS NOT SELF-DRAINING

AutoCAD SHX Text

TEST PLUG (TYP.)

AutoCAD SHX Text

PIPE HANGER SHALL SUPPORT PIPING INDEPENDENT OF COIL

AutoCAD SHX Text

REDUCER, IF REQUIRED

AutoCAD SHX Text

DRAIN

AutoCAD SHX Text

WATER COIL

AutoCAD SHX Text

AIR VENT WHEN COIL IS NOT SELF-VENTING

AutoCAD SHX Text

TEST PLUG (TYP.)

AutoCAD SHX Text

PIPE HANGER SHALL SUPPORT PIPING INDEPENDENT OF COIL

AutoCAD SHX Text

WATER COIL

AutoCAD SHX Text

REDUCER, IF REQUIRED

AutoCAD SHX Text

FLOW ELEMENT

AutoCAD SHX Text

DRAIN WHEN COIL IS NOT SELF-DRAINING

AutoCAD SHX Text

DRAIN

AutoCAD SHX Text

%%UDOUBLE COIL

AutoCAD SHX Text NOTES: 1. WHEN COIL IS INCLUDED IN CASING MOUNTED ON VIBRATION ISOLATORS THE FIRST 2 WHEN COIL IS INCLUDED IN CASING MOUNTED ON VIBRATION ISOLATORS THE FIRST 2 HANGERS FOR EACH PIPE SHALL BE SPRING & NEOPRENE TYPE. TYPE "H" FOR 100mm [4"] PIPE & SMALLER. TYPE "H-P" FOR 125mm [5"] PIPE & LARGER.2. PIPING SHALL BE INSTALLED IN SUCH MANNER THAT IT WILL NOT BLOCK THE SWING OR PIPING SHALL BE INSTALLED IN SUCH MANNER THAT IT WILL NOT BLOCK THE SWING OR USE OF ACCESS DOORS OR PANELS; NEITHER SHALL IT BLOCK THE SERVICING OF FILTERS, VALES, OR EQUIPMENT. 3. THE FLOW ELEMENT MAY BE INSTALLED IN THE SUPPLY PIPING IF THE REQUIRED MINIMUM THE FLOW ELEMENT MAY BE INSTALLED IN THE SUPPLY PIPING IF THE REQUIRED MINIMUM UPSTREAM AND DOWNSTREAM DIMENSIONS CANNOT BE OBTAINED IN THE RETURN PIPING.

AutoCAD SHX Text

FE

AutoCAD SHX Text

MV

AutoCAD SHX Text

MV

AutoCAD SHX Text

MV

AutoCAD SHX Text

MV

AutoCAD SHX Text

MV

AutoCAD SHX Text

MV

AutoCAD SHX Text

FE

AutoCAD SHX Text

TI

AutoCAD SHX Text

TI

AutoCAD SHX Text

TEMPERATURE INDICATION TO ECC SEE CONTROL DIAGRAM

AutoCAD SHX Text

MV

AutoCAD SHX Text

CALIBRATED BALANCING VALVE (TYP.)

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

%%USTEAM TRAP ASSEMBLY

AutoCAD SHX Text

[6"] MIN.

AutoCAD SHX Text [12"]

AutoCAD SHX Text

[6"] MIN.

AutoCAD SHX Text

[12"] MIN.

AutoCAD SHX Text

DRIP LEG (TYP.)

AutoCAD SHX Text 20mm [3/4"] DRAIN (ALTERNATE LOCATIONS) (TYPICAL)

AutoCAD SHX Text

STEAM LINE (TYPICAL)

AutoCAD SHX Text

CAP (TYPICAL)

AutoCAD SHX Text

PIPE T0 STEAM TRAP (TYPICAL)

AutoCAD SHX Text

NOTE: DRIP POCKET PIPE SIZE SAME AS STEAM MAIN UNLESS OTHERWISE NOTED.

AutoCAD SHX Text

STEAM LINE DRIP POCKET

AutoCAD SHX Text 20mm [3/4"] MIN.

AutoCAD SHX Text

FROM DRIP CONNECTION

AutoCAD SHX Text

DRIP RETURN

AutoCAD SHX Text 10mm [3/8"] TEST CONNECTION

AutoCAD SHX Text

STEAM LINE DRIP POCKET AND STEAM TRAP ASSEMBLY

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text NOTE: ALL DRIP POINTS ON STEAM MAINS SHALL BE PROVIDED WITH A 300mm [12"] MINIMUM HIGH DRIP LEG FROM BOTTOM OF STEAM MAIN TO TRAP INLET. DRIP LEG SHALL HAVE 150mm [6"] SCALE POCKET BELOW TRAP INLET.

AutoCAD SHX Text

TO RETURN MAIN

AutoCAD SHX Text

PIPE SIZE SHALL BE SAME SIZE AS TRAP

AutoCAD SHX Text

FLOAT AND THERMOSTATIC TRAP. SEE PLANS, AND SCHEDULES

AutoCAD SHX Text

DIELECTRIC FITTING WHERE RETURN IS COPPER PIPE

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

SCHEDULE 80 STEEL PIPE

AutoCAD SHX Text BYPASS-INSTALL IN HORIZONTAL PLANE LEVEL WITH TRAP OR IN VERTICAL PLANE & BELOW TRAP PROVIDE BYPASS PIPING FOR ALL TRAPS 25mm [1"] AND LARGER.

AutoCAD SHX Text 300mm

AutoCAD SHX Text 150mm

AutoCAD SHX Text DRIP LEG OR EQUIPMENT CONNECTION. MAKE THE SAME SIZE AS THE SUPPLY MAIN OR EQUIPMENT CONNECTION. SEE NOTE 1

AutoCAD SHX Text

[12" MIN.]

AutoCAD SHX Text

[6" MIN.]

AutoCAD SHX Text

SCHEDULE 80 STEEL PIPE

AutoCAD SHX Text

SEE DRAWINGS FOR PIPE SIZES

AutoCAD SHX Text 25mm [1"] GATE VALVE

AutoCAD SHX Text

USE 4-BOLT RAISED FACE FLANGES

AutoCAD SHX Text

FLOAT AND THERMOSTATIC STEAM TRAP ASSEMBLY

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

END OF STEAM LINE DRIP TRAP

AutoCAD SHX Text

CONDENSATE

AutoCAD SHX Text

STEAM PIPE

AutoCAD SHX Text

CLEAN STEAM GENERATOR

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

WHENEVER PIPING AND EQUIPMENT

AutoCAD SHX Text

STEEL ANGLES

AutoCAD SHX Text

BEAM

AutoCAD SHX Text

PROVIDE SUPPLEMENTAL 3"X3"X1/2"

AutoCAD SHX Text

CAN NOT BE SUPPORTED FROM BEAMS

AutoCAD SHX Text

CONTINUOUS

AutoCAD SHX Text

WELD TO BEAM

AutoCAD SHX Text

BEAM CLAMP

AutoCAD SHX Text

HANGER ROD

AutoCAD SHX Text

HANGER ROD

AutoCAD SHX Text

STEEL ROOF

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

STEAM HUMIDIFIER DETAIL

AutoCAD SHX Text

NTS

AutoCAD SHX Text

AutoCAD SHX Text 3/4"

AutoCAD SHX Text

ATMOSPHERIC

AutoCAD SHX Text

STEAM

AutoCAD SHX Text

3/4" BLOWDOWN TO

AutoCAD SHX Text

FLOOR DRAIN

AutoCAD SHX Text

6" P TRAP

AutoCAD SHX Text

3/4" CONDENSATE

AutoCAD SHX Text

RETURN

AutoCAD SHX Text

TO FLOOR DRAIN

AutoCAD SHX Text

SS STEAM HEADER

AutoCAD SHX Text

6" MIN.

AutoCAD SHX Text

HOSE CUFF

AutoCAD SHX Text

FROM STEAM

AutoCAD SHX Text

GENERATOR

AutoCAD SHX Text

COPPER OR SS PIPE

AutoCAD SHX Text

WITH 1" INSULATION

AutoCAD SHX Text

SEE SIZE IN DWG

AutoCAD SHX Text

STAINLESS STELL

AutoCAD SHX Text

STEAM TUBES

AutoCAD SHX Text

DUCT UP AHU

AutoCAD SHX Text

TO CONDENSATE

AutoCAD SHX Text

RETURN

AutoCAD SHX Text

PIPE AND DUCT SUPPORT

AutoCAD SHX Text

DETAIL FOR MER

AutoCAD SHX Text

WATER LEVEL

AutoCAD SHX Text

SET @15 PSIG

AutoCAD SHX Text

FOR COLD WATER FEED

AutoCAD SHX Text

SEE PLUMBING DWG.

AutoCAD SHX Text

ATM STM

AutoCAD SHX Text

MODULATING LEVEL

AutoCAD SHX Text

CONTROL VALVE

AutoCAD SHX Text

PC

AutoCAD SHX Text

PT

AutoCAD SHX Text

SHUTOFF VALVE

AutoCAD SHX Text

MIST ELIMINATOR

AutoCAD SHX Text

FEEDWATER

AutoCAD SHX Text

F&T TRAP ASSEMBLY

AutoCAD SHX Text

LPS

AutoCAD SHX Text

STEAM CONTROL

AutoCAD SHX Text

VALVE

AutoCAD SHX Text

LC

AutoCAD SHX Text

LT

AutoCAD SHX Text

TO HUMIDIFIER(S)

AutoCAD SHX Text

1" GATE VALVE

AutoCAD SHX Text

SCHEDULE 80 STEEL PIPE

AutoCAD SHX Text

WELDED

AutoCAD SHX Text

TEE

AutoCAD SHX Text

INVERTED BUCKET

AutoCAD SHX Text

TRAP ASSEMBLY

AutoCAD SHX Text

TO BUILDING

AutoCAD SHX Text

LOAD

AutoCAD SHX Text

MANUAL

AutoCAD SHX Text

AIR VENT

AutoCAD SHX Text

MV

AutoCAD SHX Text

TO DRAIN

AutoCAD SHX Text

TEST TEE

AutoCAD SHX Text

BYPASS VALVE

AutoCAD SHX Text

BACK FLOW PREVENTOR

BYPASS VALVE

HVAC DETAILS 3

1-MH703

J.O. N.R.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

MEP Consultant:

Project Director

20 Dec 2018Revisions: Date:

630-17-104

423 EAST 23RD STREET, NEW YORK, NY

RENOVATE ONCOLOGY PHARMACY

MICHAEL AVRAMIDES ARCHITECT

319 E 50TH STREET, STUDIO E

NEW YORK, NY 10022

T:917.855.8111

ONSULTING NGINEERS

KALLEN & LEMELSON, LLP

P: (212) 643-9898 F: (212) 643-2332

IGHTH VENUE, TH LOOR, EW ORK, 520 E

A 17 F N Y

C E

NY 10018

AutoCAD SHX Text

5 FT

AutoCAD SHX Text

AutoCAD SHX Text

THRU [20]

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text [32]

AutoCAD SHX Text [25]

AutoCAD SHX Text [40]

AutoCAD SHX Text

AutoCAD SHX Text [65]

AutoCAD SHX Text

AutoCAD SHX Text [50]

AutoCAD SHX Text

AutoCAD SHX Text [75]

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text [125]

AutoCAD SHX Text [100]

AutoCAD SHX Text

AutoCAD SHX Text [150]

AutoCAD SHX Text

AutoCAD SHX Text [250]

AutoCAD SHX Text

AutoCAD SHX Text [200]

AutoCAD SHX Text

AutoCAD SHX Text [300]

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text [400]

AutoCAD SHX Text

AutoCAD SHX Text [350]

AutoCAD SHX Text

AutoCAD SHX Text [450]

AutoCAD SHX Text

AutoCAD SHX Text [600]

AutoCAD SHX Text

AutoCAD SHX Text [500]

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 2 1/2

AutoCAD SHX Text 1 1/2

AutoCAD SHX Text

AutoCAD SHX Text 1 1/4

AutoCAD SHX Text [9100]

AutoCAD SHX Text [9600]

AutoCAD SHX Text [8500]

AutoCAD SHX Text [7600]

AutoCAD SHX Text [8200]

AutoCAD SHX Text [7000]

AutoCAD SHX Text [5800]

AutoCAD SHX Text [6700]

AutoCAD SHX Text [5200]

AutoCAD SHX Text [4100]

AutoCAD SHX Text [4900]

AutoCAD SHX Text [3700]

AutoCAD SHX Text [3000]

AutoCAD SHX Text [3400]

AutoCAD SHX Text [2700]

AutoCAD SHX Text [2100]

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text [4900]

AutoCAD SHX Text

AutoCAD SHX Text [4100]

AutoCAD SHX Text [3700]

AutoCAD SHX Text [4000]

AutoCAD SHX Text

AutoCAD SHX Text [3000]

AutoCAD SHX Text [2400]

AutoCAD SHX Text [1800]

AutoCAD SHX Text [1500]

AutoCAD SHX Text

THRU 3/4

AutoCAD SHX Text

AutoCAD SHX Text [2100]

AutoCAD SHX Text [2100]

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text [2100]

AutoCAD SHX Text

AutoCAD SHX Text [2700]

AutoCAD SHX Text

AutoCAD SHX Text [2400]

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

MV

AutoCAD SHX Text

OR

AutoCAD SHX Text

AV

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

FLEXIBLE DUCT CONNECTIONS

AutoCAD SHX Text

%%UROUND FLEXIBLE CONNECTION

AutoCAD SHX Text

%%URECTANGULAR FLEXIBLE CONNECTION

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

(WITH EQUIPMENT MOUNTED IN DUCT)

AutoCAD SHX Text

DUCTWORK TRANSITIONS

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

SHIM AS

AutoCAD SHX Text

REQUIERED

AutoCAD SHX Text

%%UNOTE:

AutoCAD SHX Text

1. PIPE SUPPORT SPACED A MINIMUM OF EVERY 6 FEET

AutoCAD SHX Text

DUCT AND PIPE SUPPORT

AutoCAD SHX Text

%%UFROM EXTERIOR WALL

AutoCAD SHX Text

PIPE

AutoCAD SHX Text

14" GAUGE 6"

AutoCAD SHX Text

WIDE

AutoCAD SHX Text

STAINLESS STEEL

AutoCAD SHX Text

STRAP.

AutoCAD SHX Text

4" LONG SS

AutoCAD SHX Text

MASONARY EXPANSION

AutoCAD SHX Text

BOLTS

AutoCAD SHX Text

WALL

AutoCAD SHX Text

MAX.

AutoCAD SHX Text

MAX.

AutoCAD SHX Text

MAX.

AutoCAD SHX Text 15°

AutoCAD SHX Text 15°

AutoCAD SHX Text

MAX.

AutoCAD SHX Text 15°

AutoCAD SHX Text 15°

AutoCAD SHX Text

%%UTYPICAL DUCTWORK TRANSITION WITH

AutoCAD SHX Text

%%UEQUIPMENT MOUNTED IN DUCT

AutoCAD SHX Text

%%UPLAN OR SIDE VIEW

AutoCAD SHX Text

%%UTYPICAL DUCTWORK TRANSITION

AutoCAD SHX Text

%%UPLAN OR SIDE VIEW

AutoCAD SHX Text

AIR

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

AIR

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

EQUIPMENT

AutoCAD SHX Text

MAX.

AutoCAD SHX Text 30°

AutoCAD SHX Text

MAX.

AutoCAD SHX Text 30°

AutoCAD SHX Text

%%UNOTE:

AutoCAD SHX Text

UNLESS OTHERWISE INDICATED ON PLANS, MAXIMUM ANGLES SHOWN SHALL APPLY.

AutoCAD SHX Text

FLEXIBLE MATERIAL

AutoCAD SHX Text

AS SPECIFIED

AutoCAD SHX Text

WASHER

AutoCAD SHX Text

FLANGED

AutoCAD SHX Text

CONNECTION

AutoCAD SHX Text

ON FAN SIDE

AutoCAD SHX Text 1 1/2" [40mm] MIN. TO 3" [75mm]

AutoCAD SHX Text MAX. INSTALLED. 6" [150mm]

AutoCAD SHX Text

NOMINAL WITH MATERIAL TAUT

AutoCAD SHX Text [40mm]

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text [15mm]

AutoCAD SHX Text 1/2"

AutoCAD SHX Text [15mm]

AutoCAD SHX Text 1/2"

AutoCAD SHX Text

SHEET METAL AS

AutoCAD SHX Text

SPECIFIED FOR

AutoCAD SHX Text

DUCTWORK.

AutoCAD SHX Text

DUCT

AutoCAD SHX Text 1 1/2" [40mm]

AutoCAD SHX Text

POCKET SLIP

AutoCAD SHX Text

ALTERNATE

AutoCAD SHX Text

POSITION

AutoCAD SHX Text

OF BOLT

AutoCAD SHX Text 1" [25mm] FLANGE & HEM

AutoCAD SHX Text BOLT ON 4" [100mm] CENTERS

AutoCAD SHX Text 1"x1/8" [25x3mm] BAND IRON

AutoCAD SHX Text

SHEET METAL AS

AutoCAD SHX Text

SPECIFIED FOR

AutoCAD SHX Text

DUCTWORK.

AutoCAD SHX Text

RIVET ON 4"

AutoCAD SHX Text [100mm]

AutoCAD SHX Text

CENTERS

AutoCAD SHX Text

SHEET METAL SCREWS ON

AutoCAD SHX Text 12" [300mm] CENTERS

AutoCAD SHX Text

DUCT

AutoCAD SHX Text 5/16" [8mm] FLANGE

AutoCAD SHX Text BOLT ON 4" [100mm] CENTERS

AutoCAD SHX Text 1"x1/8" [25x3mm] BAND IRON

AutoCAD SHX Text 1"x1/8" [25x3mm] DRAW BAND

AutoCAD SHX Text

FLEXIBLE

AutoCAD SHX Text

MATERIAL AS

AutoCAD SHX Text

SPECIFIED

AutoCAD SHX Text 1-1/2" [40mm] MIN. TO 3" [75mm]

AutoCAD SHX Text MAX. INSTALLED. 6" [150mm]

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.