5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.
is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO:
Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer) 04-24-2019 526-19-1-5019-0007 526-18-134 36C242 Department of Veterans Affairs Network Contracting Office 2 James J. Peters VA Medical Center 130 West Kingsbridge Road Bronx NY 10468-3904 36C242 Department of Veterans Affairs James J. Peters VA Medical Center Network Contracting Office 2 130 West Kingsbridge Road Bronx NY 10468-3904 To all Offerors/Bidders
36C24219B0015 03-21-2019
X X X ** HOUR & DATE for Receipt of Offers is EXTENDED to:
X AMENDMENT 00001 to INVITATION FOR BID Solicitation 36C24219B0015 526-18-134 Animal Research Trailer Disposal & Site Restoration.
The purpose of this Amenedment 00001 is to:
1. This Amenedment extends the Response Due Date Deadline to Wednesday May 8, 2019 11:15 AM ET. All responses must be received by Wednesday May 8, 2019 11:15 AM ET. Response address information remains the same.
2.
Request for Information Questions (RFI Questions) were received and answers are posted here with 6 photos
3. The Sign In Sheet from the Pre-bid Walk Thru held April 3, 2019 is posted here.
This Amendment 00001 reposted due to pagination issue, only 1 Amendment 00001 to be signed.
ALL OTHER TERMS AND CONDITIONS REMAIN THE SAME AND UNCHANGED. ALL SOLICITATION AMENDEMENTS MUST BE SIGNED ACKNOWLEDGED.
Joseph Ercole copy on file signed by CO
V31OL3185
CONTINUATION PAGE
RFIs With Answers
1) Drawings has boxes with 'Red' and 'Blue' colors. Please advise if all these red and blue color notes are part of scope of the work.
Please pay attention to only the colored comment boxes and lines. The drawings are made by marking up existing drawings. Please disregard the old notes in black.
2) Drawing A-002 is missing.
A-002 is not a required drawing. It is referenced from the old notes (in black). Please disregard those notes.
3) Please define the correct scope of the work for plumbing work. Also, what is the grey PVC pipe under trailer for (it is understood it needs to be removed).
Contractor is to demolish all plumbing lines going to and from the trailers. The water line is copper and is connected to the hose bib outside of the Research Building and runs into both Trailers, with parts of the piping underground (see attached pictures). The sanitary lines come out of the trailers in multiple locations and is tied into a main line that is connected to the manhole outside of the gated area. Demolish these lines and seal the manhole penetration. The lines are not installed exactly as shown in P1.00. I’ve attached pictures of the original installation showing 2 sanitary lines connecting the trailers entering a main line running parallel to the trailers and sidewalk before turning towards the manhole.
The “grey” PVC pipe might be the white PVC that is sanitary line shown in the attached pictures or, if it is actually grey, then it is the electrical lines that was installed in a different path than shown on the drawings. The past installers could have run the electrical lines perpendicular to the transformer pad underground then brought them up under the trailers to save on burying large portions of the electrical conduit. Contractor to confirm during demolition if this is correct. The labor should be less extensive due to less excavation work if this is true.
4) Please clarify how many footings are to be removed from under the trailer. Also, all the existing steel beams has to be removed by contractor.
All the footings are to be removed. There are 14 footings per trailer as per my inspections and records. Contractor to confirm exact number of footings. There are also footings under the wooden walkway that must be removed. The numbers of footings under the walkway should be more than 6, but the exact number is not known until the walkway is removed. Steel beams should be a part of the trailer structure that will be removed by the company disposing the trailers. Contractor is expected to remove the skirt and wooden members under the steel beams to get to the utilities under the trailers.
5) After the trailers are removed does contractor has to restore the site area with top soil and seed?
Yes.
6) Page 2 of solicitation document is blank.
During pagination a Blank Page 2 was created Blank (from page break), however all information is in the Solicitation and Page 2 is Intentionally Blank.
7) Please advise which work is in scope of the work on drawing E5.01 That drawing is a riser diagram of the electrical wiring as it is now. The contractor should review the red notes to get the scope of the electrical modifications, which include demolishing the existing electrical wires and conduit up to a certain point, turning over electrical equipment, and installing a weather-rated underground pull box to keep the wires for future use. The contractor should also excavate around the penetration point into the research building and reseal the conduits. I’ve attached a photo of the previous installation to show the conduit penetrations.
-END OF QUESTIONS AND ANSWERS-
PICTURES BELOW AND THIS AMENDMENT ENDS WITH SIGN IN SHEET BELOW
image5.jpeg image6.jpeg image7.emf image1.jpeg image2.jpeg image3.jpeg image4.jpeg