36C24218R0519-008.pdf

PDF 894 KB Posted

Attached to
Project 526-18-133 Emergency Power Repair to Building 107
Solicitation number
36C24218R0519
Issued by

About this file

36C24218R0519 EMERGENCY REPAIR TO ELECTRICAL POWER TO BLDG.107 D-1.pdf

View the file

Other files

File Type Posted
36C24218R0519-009.pdf PDF
36C24218R0519-007.docx DOCX document
36C24218R0519-010.docx DOCX document
36C24218R0519-006.docx DOCX document
36C24218R0519-005.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

ELEV

AutoCAD SHX Text

STAIR NO.U

AutoCAD SHX Text

ELEV.MACHINE

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

CLOS.

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

EQUIPMENT ROOM

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text

STAIR NO.2

AutoCAD SHX Text H.A.C

AutoCAD SHX Text

SOILED

AutoCAD SHX Text

LINEN

AutoCAD SHX Text

HOLDING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

TRASH

AutoCAD SHX Text

HOLDING

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

MECH.

AutoCAD SHX Text

SHAFT

AutoCAD SHX Text P1

AutoCAD SHX Text

TELEPHONE

AutoCAD SHX Text

CLOSET

AutoCAD SHX Text

CONNECTING TUNNEL

AutoCAD SHX Text

GA09

AutoCAD SHX Text

UNEXCAVATED

AutoCAD SHX Text

GA03

AutoCAD SHX Text P2

AutoCAD SHX Text P3

AutoCAD SHX Text

GA01

AutoCAD SHX Text

GA02

AutoCAD SHX Text

GA04

AutoCAD SHX Text

GA05

AutoCAD SHX Text

GA06

AutoCAD SHX Text

GA07

AutoCAD SHX Text

GA08

AutoCAD SHX Text

GA08A

AutoCAD SHX Text

TUNNEL

AutoCAD SHX Text

MECH

AutoCAD SHX Text

SHAFT

AutoCAD SHX Text

ABOVE

AutoCAD SHX Text

BASEMENT

AutoCAD SHX Text 52.48

AutoCAD SHX Text 121.94

AutoCAD SHX Text 160.04

AutoCAD SHX Text 547.78

AutoCAD SHX Text 108.33

AutoCAD SHX Text 152.54

AutoCAD SHX Text 253.81

AutoCAD SHX Text 152.63

AutoCAD SHX Text 166.21

AutoCAD SHX Text 71.50

AutoCAD SHX Text 32.67

AutoCAD SHX Text 107.00

AutoCAD SHX Text 48.00

AutoCAD SHX Text 860.49

AutoCAD SHX Text 6629.85

AutoCAD SHX Text PANEL ENCLOSURE NEMA 4, SIZE TO BE DETERMINED AND VERIFIED IN FIELD BY CONTRACTOR

AutoCAD SHX Text EXISITNG 2" STEEL CONDUIT TO BE CUT AND SPLICE BOX INSTALLED. OLD CONDUCTORS REMOVED, CAPPED AND SEALED.

AutoCAD SHX Text INSTALL NEW 3/0 HOT CONDUCTORS AND #4 GROUND. SPLICE TO EXITING CONDUCTORS FEEDING CHAPEL BLDG. LOADS.

AutoCAD SHX Text INSTALL NEW 3" RIGID METAL CONDUIT AND ROUTE TO 480 V SUBSTATION. INSTALL A NEW 200 AMP BREAKER IN PANEL MDS AT ELECTRICAL ROOM DIRECTLY ABOVE AND TIE INTO NEW BREAKER.

AutoCAD SHX Text

TOP VIEW OF WALL PENETRATION

AutoCAD SHX Text

EXISITNG CONDUIT AND CONDUCTORS FEEDING LOAD AT CHAPEL BLDG TO BE SPLICED INTO

AutoCAD SHX Text FIRE STOPPING WITH MATERIALS HAVING UL CERTIFICATION SHALL BE PERFORMED AT ALL CONDUIT PENETRATIONS OF FIRE WALLS, FIRE PARTITIONS, SMOKE PARTITIONS OR FLOORS. ALL SMOKE/FIRE STOPPED PENETRATIONS MUST HAVE A MINIMUM 2-HOUR RATING.

AutoCAD SHX Text APPROVED RUBBERIZED OR OTHER WATERPROOF SEALER OF AN APPLIED DEPTH OF AT LEAST 2."

AutoCAD SHX Text EUSCUTCHEON PLATE ON BOTH SIDES TO COVER HOLE (ONLY REQ'D. IF VISIBLE UPON JOB COMPLETION)

AutoCAD SHX Text

CONDUIT

AutoCAD SHX Text

FLOOR/CEILING CONSTRUCTION

AutoCAD SHX Text

CORE DRILLED HOLE NO MORE THAN 1" LARGER IN DIA. THAN CONDUIT

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Revisions

AutoCAD SHX Text

VA FORM 08-6231, OCT 1978

AutoCAD SHX Text F

AutoCAD SHX Text Date

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Professional Seal

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VAMC BRONX

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ELECTRICAL POWER TO BLDG. 107

AutoCAD SHX Text Approved: Project Manager

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Location

AutoCAD SHX Text

AutoCAD SHX Text Project Title

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Checked

AutoCAD SHX Text Drawn

AutoCAD SHX Text Project No.

AutoCAD SHX Text Drawing No.

AutoCAD SHX Text Date

AutoCAD SHX Text

VAMC, BRONX

AutoCAD SHX Text Department of

AutoCAD SHX Text Veterans Affairs

AutoCAD SHX Text

VA

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

BASEMENT FLOOR PLAN

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 03-25-2018

AutoCAD SHX Text

EMERGENCY REPAIR TO

AutoCAD SHX Text

ELECTRICAL POWER TO

AutoCAD SHX Text N.Y.

AutoCAD SHX Text

BLDG. 107

AutoCAD SHX Text 526-18-133

AutoCAD SHX Text D-1

AutoCAD SHX Text 480 V Disconnect

AutoCAD SHX Text

REMOVE ALL CONDUCTORS THAT POWERED BLDG. 107 TO EXISTING TROUGH.

AutoCAD SHX Text

EXISITNG POWER FEED THAT CONNECTS TO BLDG. 107 TRANSFORMER AND LOADS

AutoCAD SHX Text DETERMINE PROPER LOCATION TO CUT CONDUIT AND INSTALL ADEQUATE SIZED SPLICE BOX TO ROUTE NEW FEED TO 480 V SUBSTATION TO ROOM DIRECTLY ABOVE. CAP AND SEAL ALL CONDUIT ON ABANDONED CONDUIT ONCE CONDUCTORS REMOVED.

AutoCAD SHX Text

%%UDETAIL "A"

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text D-1

AutoCAD SHX Text A

AutoCAD SHX Text D-1

AutoCAD SHX Text

%%UDETAIL "B"

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text D-1

AutoCAD SHX Text B

AutoCAD SHX Text D-1

Sheets and Views
EMERGENCY REPAIR TO ELECTRICAL POWER TO BLDG.107 D-1 with notes-BASEMENT

File details come from the government source that posted it.