36C24126Q0719.docx

DOCX document 26 KB Posted

Attached to
6515--Sources Sought Notice - Syringe Pumps - White River Junction VAMC
Solicitation number
36C24126Q0719
Issued by

About this file

This is a Sources Sought Notice issued by the Department of Veterans Affairs Network Contracting Office 1 (NCO 1) on behalf of the White River Junction VA Medical Center (WRJ VAMC) for market research purposes. The notice is not a formal solicitation and does not constitute a commitment to award a contract. The solicitation number is 36C24126Q0719, with a response deadline of August 17, 2026, at 1:00 PM Eastern Time. The contracting office is located in Augusta, Maine (zip code 04330), and the place of performance is White River Junction VA Medical Center in White River Junction, Vermont.

The requirement is for ICU Medical Medfusion 4000 Syringe Infusion Pumps with associated software, accessories, installation, and training services to support multiple clinical environments requiring precise small-volume drug delivery. Equipment specifications include delivery accuracy of ±2%, flow rates from 0.01 mL/hr to 1130 mL/hr, automatic syringe detection for 1-60 mL syringes, customizable drug libraries, FlowSentry pressure monitoring technology, and PharmGuard software. Only new equipment is acceptable; no refurbished units are permitted. The vendor must provide complete installation services, deployment configuration, technical checks, one-year manufacturer warranty, and comprehensive training for all clinical staff including providers, technicians, and biomedical engineers. Responses should include company information (SAM UEI, CAGE code, business size and socioeconomic status), capability statements demonstrating experience with similar medical devices, authorized distributor certification from ICU Medical/Smith Medical, delivery and lead time estimates, and relevant past performance references. The government has determined that no equivalent domestic end products are available; however, vendors may propose suitable domestic alternatives if they can demonstrate full technical equivalency. No pricing is required at this stage. The primary contact is Contract Specialist Dewan Britton (Dewan.Britton@va.gov, 910-343-5300), and all responses must be submitted via email only.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
Sources Sought Notice - Syringe Pumps - White River Junction VAMC

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
04330
SOLICITATION NUMBER*
36C24126Q0719
RESPONSE DATE/TIME/ZONE
08-17-2026 1PM EASTERN TIME, NEW YORK, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
339112
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 1 (NCO 1) Contracting Officer (90C) 1 VA Center Augusta ME 04330

POINT OF CONTACT*

Contract Specialist Dewan Britton Dewan.Britton@va.gov 910-343-5300

PLACE OF PERFORMANCE

ADDRESS
Department of Veterans Affairs

Veterans Health Administration

White River Junction VA Medical Center

163 Veterans Drive

White River Junction VT

POSTAL CODE
05009-0001
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov/
URL DESCRIPTION
Department of Veterans Affairs
AGENCY CONTACT’S EMAIL ADDRESS
Dewan.Britton@va.gov
EMAIL DESCRIPTION
Contract Specialist's Email

DESCRIPTION

This Sources Sought Notice is issued solely for market research and planning purposes. It does not constitute a solicitation, nor is it a request for quotes, and shall not be construed as a commitment by the Government to issue a solicitation or make an award.

1. Purpose of the Notice The White River Junction VA Medical Center (WRJ VAMC) is conducting market research to identify qualified and capable sources (large or small; including SDVOSB/VOSB) that can provide ICU Medical Medfusion 4000 Syringe Infusion Pumps, associated software, accessories, installation, and training services. The requirement supports multiple clinical environments requiring precise small‑volume drug delivery.

2. Description of the Requirement The Government requires:

· Medfusion 4000 syringe infusion pumps

· Delivery accuracy ±2%, flow rates 0.01 mL/hr to 1130 mL/hr

· Automatic syringe detection (1 mL–60 mL)

· Smart pump safety features including customizable drug libraries and FlowSentry pressure monitoring technology

· PharmGuard software for drug library customization specific to WRJ VAMC clinical needs

· Equipment specifications

· New equipment only (no refurbished units)

· Vendor-supported OS

· Delivery, setup, software configuration, calibration, and user/account management

· Training

· User manuals, service manuals

· On‑station clinical and technical training

· Cleaning and maintenance guidelines

· Training for all clinical staff: providers, technicians, biomedical engineers, and other designated users

· Installation Services

· Complete deployment, configuration, technical checks, trash removal

· Coordination with Biomed staff and WRJ VAMC project POC

· One-year manufacturer warranty

· Vendor to provide all tools/materials required for full installation

3. Delivery Information Delivery Location:

White River Junction VA Medical Center 163 Veterans Drive White River Junction, VT 05009

4. Requested Response Information Interested parties are asked to submit the following:

1. Company Information

· Company Name, SAM UEI, CAGE code

· Business size & socioeconomic status (SDVOSB, VOSB, Small Business, etc.)

2. Capability Statement

· Ability to provide ICU Medical Medfusion 4000 pumps, software, accessories

· Experience with installation and clinical training for similar medical devices

· Ability to meet VA requirements (equipment specs, warranty, manuals, deployment schedule)

3. Authorized Distributor Certification

· Proof of authorized reseller/distributor status for ICU Medical/Smith Medical products

4. Delivery & Lead Time Estimates

5. Past Performance

· Relevant projects in the last 3–5 years involving medical infusion devices

5. Important Notes

· This is NOT a solicitation; no pricing is required at this stage.

· The Government will not reimburse costs associated with responding to this notice.

· Email submissions only; no paper submissions will be accepted.

6. Domestic Alternatives Statement Market research conducted by the White River Junction VA Medical Center indicates that no equivalent domestic end products are available for this requirement. Vendors may still propose suitable domestic products only if they can demonstrate full technical equivalency to the ICU Medical Medfusion 4000 syringe infusion pumps.

7. Primary Contact for Responding Vendors Please submit all responses via email to:

Dewan.Britton@va.gov Subject Line: Sources Sought – Medfusion 4000 Syringe Pumps (WRJ VAMC)

*= Required Field
Sources Sought Notice

Sources Sought Notice

File details come from the government source that posted it. Updated .