36C24125Q0839 0001.docx
DOCX document 137 KB Posted
- Solicitation number
- 36C24125Q0839
About this file
This document is an Amendment of Solicitation/Modification of Contract for sterilizer preventative maintenance services issued by the Department of Veterans Affairs (VA) Boston Healthcare System. The solicitation (RFQ 36C24125Q0839) seeks a contractor to perform preventative maintenance on medical equipment at three VA facilities: Jamaica Plain, Brockton, and West Roxbury VAMCs. The procurement is now unrestricted (previously set aside for Veteran-Owned Small Businesses) and covers a base year with four optional one-year extensions, involving maintenance services for multiple sterilization and medical equipment across the three locations.
Key details include a NAICS code of 811210 with a $34.0 million small business size standard, services spanning equipment like steam autoclaves, washer disinfectors, ultrasonic cleaners, and sterilization units. The solicitation requires quotes to be submitted by Monday, September 15, 2025, at 3:00 PM EST, with award based on comparative evaluation of price and technical capabilities. Contractors must provide labor rates, equipment specification sheets, and demonstrate experience in maintaining the listed medical equipment according to manufacturer specifications, with services to be performed during standard business hours (8:00 am to 4:30 pm, Monday-Friday, excluding federal holidays).
View the file
Other files
| File | Type | Posted |
|---|---|---|
| WD 2015 4053 MA Brockton Rev30.pdf | ||
| WD 2015 4047 MA Boston Rev29.pdf | ||
| LOS certification.pdf | ||
| Past Performance Worksheet.xlsx | XLSX spreadsheet | |
| 52.212-1 Instructions to Quoters.docx | DOCX document | |
| 36C24125Q0839.docx | DOCX document | |
| Evaluation Process.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.
is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer)
36C241 Department of Veterans Affairs VAMC Providence
830 Chalkstone Avenue Providence RI 02908
36C241 Department of Veterans Affairs VAMC Providence
830 Chalkstone Avenue Providence RI 02908 To all Offerors/Bidders
36C24125Q0839
X
X X
** HOUR & DATE for Receipt of Offers is EXTENDED to: 09-15-2025 3PM EDT
The purpose of this amendment is to remove the Veteran-Owned Small (VOSB) set-aside and extend the due date to Monday, September 15, 2025 at 3:00PM.
Description
This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, “Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,” as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.
This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through the most current Federal Acquisition Circular. The most current Federal Acquisition Circular can be found at Acquisition.gov.
This solicitation is unrestricted.
The associated North American Industrial Classification System (NAICS) code for this procurement is 811210, Electronic and Precision Equipment Repair and Maintenance, with a small business size standard of $34.0 million.
The FSC/PSC is J065 Maint/repair/rebuild Of Equipment- Medical, Dental, and Veterinary Equipment and Supplies.
The VA Boston Healthcare System (HCS) is seeking a contractor to perform sterilizer preventative maintenance services on the equipment listed below.
All interested companies shall provide quotations for the following:
Supplies/Services
| Line Item |
| Description |
| Quantity |
| Unit of Measure |
| Unit Price |
| Total Price |
| 0001 |
| Base Year: Sterilizer Preventative Maintenance Services for Jamaica Plain |
| 12 |
| MO |
| 0002 |
| Base Year: Sterilizer Preventative Maintenance Services for Brockton |
| 12 |
| MO |
| 0003 |
| Base Year: Sterilizer Preventative Maintenance Services for West Roxbury |
| 12 |
| MO |
| 1001 |
| Option Year 1: Sterilizer Preventative Maintenance Services for Jamaica Plain |
| 12 |
| MO |
| 1002 |
| Option Year 1: Sterilizer Preventative Maintenance Services for Brockton |
| 12 |
| MO |
| 1003 |
| Option Year 1: Sterilizer Preventative Maintenance Services for West Roxbury |
| 12 |
| MO |
| 2001 |
| Option Year 2: Sterilizer Preventative Maintenance Services for Jamaica Plain |
| 12 |
| MO |
| 2002 |
| Option Year 2: Sterilizer Preventative Maintenance Services for Brockton |
| 12 |
| MO |
| 2003 |
| Option Year 2: Sterilizer Preventative Maintenance Services for West Roxbury |
| 12 |
| MO |
| 3001 |
| Option Year 3: Sterilizer Preventative Maintenance Services for Jamaica Plain |
| 12 |
| MO |
| 3002 |
| Option Year 3: Sterilizer Preventative Maintenance Services for Brockton |
| 12 |
| MO |
| 3003 |
| Option Year 3: Sterilizer Preventative Maintenance Services for West Roxbury |
| 12 |
| MO |
| 4001 |
| Option Year 4: Sterilizer Preventative Maintenance Services for Jamaica Plain |
| 12 |
| MO |
| 4002 |
| Option Year 4: Sterilizer Preventative Maintenance Services for Brockton |
| 12 |
| MO |
| 4003 |
| Option Year 4: Sterilizer Preventative Maintenance Services for West Roxbury |
| 12 |
| MO |
Total
Statement of Work
STERILIZER MAINTENANCE SERVICES
Objective: The Full-Service Maintenance Services shall include all necessary labor, tools, equipment, transportation, and parts (with the exclusions noted below) required to perform repair and preventive maintenance on the equipment listed below. All equipment shall be maintained in proper operating condition as specified by the manufacturer. The Contractor must have proven access to manufacturers (OEM) parts, manuals and schematics needed to perform the service.
Hours of coverage: 8:00 am to 4:30pm, Monday-Friday (excluding Federal Holidays) Place of Performance: The place of performance is the Boston Healthcare System:
Jamaica Plain VAMC 150 South Huntington Ave Boston, MA 02130-48170
Brockton VAMC 940 Belmont St Brockton, MA 02301-5596
West Roxbury VAMC 1400 VFW Parkway West Roxbury, MA 02132-4927
Period of Performance: The anticipated period of performance will be a one base year with four (one) year options.
Specifications of Work: Repair Services will be provided, at the request of the VA, to diagnose and correct equipment malfunctions on a routine basis. All repairs shall be performed to manufacturer’s specification by a trained technician with experience on the unit.
The Preventive Maintenance Service will be mutually scheduled in advance during contractor’s normal weekday working hours and will be performed at two (2) month intervals. Preventive maintenance inspections shall include a minimum: electrical safety testing, lubrication, adjustment, testing and replacement of faulty parts and parts which are likely to fail during the specified time of this contract, and verification of proper operation conforming to manufacturer’s specifications. Upon completion of PM, the unit must be clearly labeled with a sticker stating the date the last PM was completed and the due date of the next PM, as well as the name of the technician that performed said PM.
Documentation Requirements: At the completion of each service call/PM, the contractor will provide a written service report to Engineering. This report will clearly show the date of service, type of service performed, model and serial numbers, name of field technician(s), a description of the work performed, and a list of any parts replaced. All Documentation shall be electronically transmitted to the COR.
Service and Parts Not Covered or Excluded by Contractor: COR authorization must be received prior to performance of any work or parts outside the scope of this contract or payment will not be authorized. Work and parts outside the scope of this contract are:
Consumables including charts, paper roll, ink cartridges, lamps lubricants, test items, cleaning agents, sterilization agent, printer paper and similar items are not covered. Expendable parts, such as filters, gaskets/seals, trap elements, fuses, detergent squeeze tubes, light handles, technician supplies, and similar items are not covered.
Overhaul or rebuild, upgrade or modification of contracted equipment. Industry standard exclusions such as heat exchangers, sonic & scope washer lid assemblies are not covered.
Service visits due to equipment failure resulting from operator error, misuse by any party, or improper operations or when after inspection of the equipment in question by contractor, it is determined that, in fact, no repair was required.
Visits to perform preventive maintenance and safety inspections on equipment which was not available, or which could not be located at the time of a previously scheduled preventive maintenance and safety inspection.
Service visits due to damage or loss caused by fire, theft, explosions, strikes, floods, riots, power failures, unauthorized repair, or any other cause beyond the control of contractor.
Additions And Deletions Under the terms of the contract similar and identical equipment may be added or deleted. Pricing shall be communicated with and negotiated with the Contracting office at the time of each occurrence.
Equipment List SPS
| Machine |
| Facility |
| SN# |
| Belimed Steam Autoclave #1, MST-H-9-6-12 HSI |
| Brockton |
| Belimed 21635 |
| Belimed Steam Autoclave #2, MST-H-9-6-12 HIS |
| Brockton |
| Belimed 21533 |
| Sterrad NX #14, ASP |
| Brockton |
| 33090328 |
| Belimed Cart Washer |
| Brockton |
| Belimed 16937 |
| Belimed Washer #1, Model# WD 250 |
| Brockton |
| Belimed N/A |
| Belimed Washer #2, Model # WD 250 |
| Brockton |
| Belimed N/A |
| Ultrasonic - Steris Innowave Unity 20 Sonic Irrigator 208V 60Hz |
| Brockton |
| 08231876202 |
| L&R Ultrasonics Quantrex, Model# Q310 |
| Brockton |
| DESCO 00725 |
| Steris Innowave Eco Tabletop Ultrasonic |
| Brockton |
| 03236273205 |
| STERRAD NX #4, ASP |
| Brockton |
| 33090009 |
| Sterrad NX100, ASP (Advanced Sterilization Products), Johnson & Johnson |
| Jamaica Plain |
| 1047180232 |
| Belimed Steam Sterilizer Machine #1, Model CL:8583, 9-6-15 HS1 |
| Jamaica Plain |
| 21615 |
| Belimed Steam Sterilizer Machine #2, Model CL:8583, 9-6-15 HS1 |
| Jamaica Plain |
| 21607 |
| Eye Sonic instruments, Sonic Systems Inc, HL series |
| Jamaica Plain |
| 17211 |
| Steris AMSCO 7000 Series Washer Disinfector, MN#7052HP |
| Jamaica Plain |
| 3600523021 |
| Belimed Washer #1, WD 290 |
| Jamaica Plain |
| 994031 |
| Belimed Washer #2, WD 290 |
| Jamaica Plain |
| VJPEE140232 |
| Evoqua RO/DI Systems |
| Jamaica Plain |
| Site ID# 0133014763 |
| Steris AMSCO Drying Cabinet Model#DCR101101 |
| Jamaica Plain |
| 6602 |
| Innowave Ultra Table Top Ultrasonic |
| Jamaica Plain |
| 0424 22822 01 |
| Innowave Ultra Table Top Ultrasonic |
| Jamaica Plain |
| 0424 84787 01 |
| Ultrasonic UW565 DVI, Belimed |
| West Roxbury |
| SN#3UW565K18061 |
| Steris Washer #21, AMSCO 7000 Series, Model# 7250HP |
| West Roxbury |
| SN#3625921008 |
| Steris Washer #22, AMSCO 7000 Series, Model# 7250HP |
| West Roxbury |
| SN#3624421009 |
| Belimed Washer #23, Model# WD 290 |
| West Roxbury |
| SN#2008554 |
| Belimed Cart Washer |
| West Roxbury |
| 17006 |
| Medivator (28L + 29R), Advantage, Steris |
| West Roxbury |
| SN#13133744 |
| Medivator (26L + 27R), Advantage, Steris |
| West Roxbury |
| SN#13133746 |
| Evoqua RO/DI Systems |
| West Roxbury |
| Site ID# 0132165957 |
| Medisafe Sonic Irrigator digital Table top Ultrasonic |
| West Roxbury |
| desco N/A |
| OR IUSS #1 |
| West Roxbury |
| 31811206 |
| OR IUSS #2 |
| West Roxbury |
| 31141002 |
Equipment List Other
| VA JP# |
| Description |
| Manufacturer |
| Model |
| Serial |
| Location |
| 69453 |
| Sterilizer |
| Castle |
| 133 |
| 99D59964 |
| F342 |
| 83552 |
| Sterilizer |
| Castle |
| 133 |
| 99D59966 |
| F353 |
| 115498 |
| Sterilizer |
| Steris |
| Lab 250 |
| 0323009-06 |
| Research room 219 |
| 69516 |
| Warming Cabinet |
| Steris |
| QDJ04 |
| 414802019 |
| 3F55 |
| 180742 |
| Warming Cabinet |
| Claflin |
| DC350 |
| 2282507 |
| PACU |
| 139140 |
| Warming Cabinet |
| Ganim Medical |
| SWC72 |
| 071612-710 |
| 2D159-1-JP |
| 139090 |
| Sterilizer |
| Steris |
| Lab 250 |
| 0317812-17 |
| Bldg 1A Rm 218 |
| OR Light |
| ALM |
| PRX 6400 |
OR 1
| OR Light |
| ALM |
| PRX 6400 |
OR 2
| OR Light |
| ALM |
| PRX 6400 |
OR 3
| OR Light |
| ALM |
| PRX 6400 |
OR 4
| OR Light |
| ALM |
| PRX 6400 |
OR 5
| OR Light |
| ALM |
| PRX 6400 |
OR 6
| OR Light |
| ALM |
| PRX 6400 |
OR 7
| OR Light |
| ALM |
| PRX 6400 |
OR 8
| OR Light |
| ALM |
| PRX 6400 |
OR 9
| OR Light |
| ALM |
| PRX 6400 |
OR 10
Equipment List Other
| VA WR# |
| Description |
| Manufacturer |
| Model |
| Serial |
| Location |
| 112594 |
| Caviwave Sonic Cleaner |
| Steris |
| CR12 |
| 96AWR9 |
| AB3-02-WR |
| 2543 |
| Bottel Washer |
| Damas Augasan |
| MK4 |
Bld. 3
| 126808 |
| OR Table |
| Steris |
| 4085 |
| 430110020 |
| OR |
| 126810 |
| OR Table |
| Steris |
| 4085 |
| 430110075 |
| OR |
| 126811 |
| OR Table |
| Steris |
| 4085 |
| 431510002 |
| OR |
| 126807 |
| OR Table |
| Steris |
| 4085 |
| 430110019 |
| OR |
| 126800 |
| OR Table |
| Steris |
| 4085 |
| 431210074 |
| OR |
| 126803 |
| OR Table |
| Steris |
| 4085 |
| 430110021 |
| OR |
| 126806 |
| OR Table |
| Steris |
| 4085 |
| 430910127 |
| OR |
| 126809 |
| OR Table |
| Steris |
| 4085 |
| 430810112 |
| OR |
| 24825 |
| Orthovision OR table |
| Steris |
| Orthovision |
| 417097035 |
| Surgical ICU |
| 139091 |
| Sterilizer |
| Steris |
| Lab 250 |
| 31811206 |
| Rm 2B13 |
| 168167 |
| Sterilizer |
| Steris |
| Lab 250 |
| 311410-02 |
| Research |
| 52907 |
| Sterilizer Gravity |
| Amsco |
| 2041 |
| 0116586-004 |
| 2B113 |
| 36420 |
| Sterilizer |
| Amsco |
| 2031 |
| 11688004 |
| Bld. 3 |
| 127334 |
| Sterilizer |
| Steris |
| FS1221001 |
A320-02
| 127335 |
| Sterilizer |
| Steris |
| FS1221001 |
A320-02
| 14984 |
| Ultrasonic Washer |
| Sonic System |
112594
| 81482 |
| Warming Cabinet |
| Amsco |
| QDJ02 |
| NSN |
| OR |
| 97424 |
| Warming Cabinet |
| Steris |
| 24" |
| 429207046 |
| A317-02-WR |
| 97422 |
| Warming Cabinet |
| Steris |
| 24" |
| 429007010 |
| A313-02-WR |
| 97421 |
| Warming Cabinet |
| Steris |
| 24" |
| 4297707050 |
| A313-02-WR |
| CHROMOPHARE OR Light |
| Stryker |
| ATO model |
| 700001945 |
| OR 1 |
| CHROMOPHARE OR Light |
| Stryker |
| ATO model |
| 700001944 |
| OR 2 |
| CHROMOPHARE OR Light |
| Stryker |
| ATO model |
| 700001946 |
| OR 3 |
| CHROMOPHARE OR Light |
| Stryker |
| ATO model |
| 700001947 |
| OR 4 |
| CHROMOPHARE OR Light |
| Stryker |
| ATO model |
| 700001948 |
| OR 5 |
RECORDS MANAGEMENT OBLIGATIONS
A. Applicability This clause applies to all Contractors whose employees create, work with, or otherwise handle Federal records, as defined in Section B, regardless of the medium in which the record exists.
B. Definitions “Federal record” as defined in 44 U.S.C. § 3301, includes all recorded information, regardless of form or characteristics, made or received by a Federal agency under Federal law or in connection with the transaction of public business and preserved or appropriate for preservation by that agency or its legitimate successor as evidence of the organization, functions, policies, decisions, procedures, operations, or other activities of the United States Government or because of the informational value of data in them.
The term Federal record:
1. includes VHA records.
2. does not include personal materials.
3. applies to records created, received, or maintained by Contractors pursuant to their VHA contract.
4. may include deliverables and documentation associated with deliverables.
C. Requirements
1. Contractor shall comply with all applicable records management laws and regulations, as well as National Archives and Records Administration (NARA) records policies, including but not limited to the Federal Records Act (44 U.S.C. chs. 21, 29, 31, 33), NARA regulations at 36 CFR Chapter XII Subchapter B, and those policies associated with the safeguarding of records covered by the Privacy Act of 1974 (5 U.S.C. 552a). These policies include the preservation of all records, regardless of form or characteristics, mode of transmission, or state of completion.
2. In accordance with 36 CFR 1222.32, all data created for Government use and delivered to, or falling under the legal control of, the Government are Federal records subject to the provisions of 44 U.S.C. chapters 21, 29, 31, and 33, the Freedom of Information Act (FOIA) (5 U.S.C. 552), as amended, and the Privacy Act of 1974 (5 U.S.C. 552a), as amended and must be managed and scheduled for disposition only as permitted by statute or regulation.
3. In accordance with 36 CFR 1222.32, the Contractor shall maintain all records created for Government use or created in the course of performing the contract and/or delivered to, or under the legal control of the Government and must be managed in accordance with Federal law. Electronic records and associated metadata must be accompanied by sufficient technical documentation to permit understanding and use of the records and data.
4. VHA and its contractors are responsible for preventing the alienation or unauthorized destruction of records, including all forms of mutilation. Records may not be removed from the legal custody of VHA or destroyed except in accordance with the provisions of the agency records schedules and with the written concurrence of the Head of the Contracting Activity. Willful and unlawful destruction, damage, or alienation of Federal records is subject to the fines and penalties imposed by 18 U.S.C. 2701. In the event of any unlawful or accidental removal, defacing, alteration, or destruction of records, the Contractor must report to VHA. The agency must report promptly to NARA in accordance with 36 CFR 1230.
5. The Contractor shall immediately notify the appropriate Contracting Officer upon discovery of any inadvertent or unauthorized disclosures of information, data, documentary materials, records, or equipment. Disclosure of non-public information is limited to authorized personnel with a need-to-know as described in the [contract vehicle]. The Contractor shall ensure that the appropriate personnel, administrative, technical, and physical safeguards are established to ensure the security and confidentiality of this information, data, documentary material, records, and/or equipment is properly protected. The Contractor shall not remove material from Government facilities or systems, or facilities or systems operated or maintained on the Government’s behalf, without the express written permission of the Head of the Contracting Activity. When information, data, documentary material, records, and/or equipment is no longer required, it shall be returned to VHA control or the Contractor must hold it until otherwise directed. Items returned to the Government shall be hand-carried, mailed, emailed, or securely electronically transmitted to the Contracting Officer or address prescribed in the [contract vehicle]. Destruction of records is EXPRESSLY PROHIBITED unless in accordance with Paragraph (4).
6. The Contractor is required to obtain the Contracting Officer's approval prior to engaging in any contractual relationship (sub-contractor) in support of this contract requiring the disclosure of information, documentary material, and/or records generated under, or relating to, contracts. The Contractor (and any sub-contractor) is required to abide by Government and VHA guidance for protecting sensitive, proprietary information, classified, and controlled unclassified information.
7. The Contractor shall only use Government IT equipment for purposes specifically tied to or authorized by the contract and in accordance with VHA policy.
8. The Contractor shall not create or maintain any records containing any non-public VHA information that is not specifically tied to or authorized by the contract.
9. The Contractor shall not retain, use, sell, or disseminate copies of any deliverable that contains information covered by the Privacy Act of 1974 or that which is generally protected from public disclosure by an exemption to the Freedom of Information Act.
10. The VHA owns the rights to all data and records produced as part of this contract. All deliverables under the contract are the property of the U.S. Government for which VHA shall have unlimited rights to use, dispose of, or disclose such data contained therein as it determines to be in the public interest. Any Contractor rights in the data or deliverables must be identified as required by FAR 52.227-11 through FAR 52.227-20.
11. Training. All Contractor employees assigned to this contract who create, work with or otherwise handle records are required to take VHA-provided records management training. The Contractor is responsible for confirming training has been completed according to agency policies, including initial training and any annual or refresher training.
VHA training for contractors is available in Talent Management System (TMS): Records Management for Records Officers and Liaisons, Item #3873736
D. Flow down of requirements to subcontractors
1. The Contractor shall incorporate the substance of this clause, its terms, and requirements including this paragraph, in all subcontracts under this [contract vehicle], and require written subcontractor acknowledgment of same.
2. Violation by a subcontractor of any provision set forth in this clause will be attributed to the Contractor.
All quoters shall submit the following:
3. Questions: Any questions must be submitted in writing no later than Thursday, September 11, 2025 at 3:00 PM EST.
2. Quote: Offeror shall provide a quote using the table above. Offerors must also provide all applicable labor rates for the solicited services so they can be compared to the applicable wage determination for compliance with the Service Contract Labor Standards.
All quotes shall be sent to the Contract Specialist, Rosangela Pereira at Rosangela.Pereira@va.gov.
Award will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of FAR 13. Comparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government.
The following are the decision factors:
1. Price: Quotes will be compared by price.
1. Technical: The offeror’s quote shall be evaluated to determine if the organization has the experience and capabilities to provide the requested services IAW the Statement of Work in a timely efficient manner.
1. Contractor shall provide specification sheets for proposed equipment and include within the solicitation response.
The award will be made to the response most advantageous to the Government. Responses should contain your best terms, conditions.
Submission of your response shall be received not later than Monday September 15, 2025 at 3:00 PM EST. All quotes shall be emailed to Rosangela Pereira at Rosangela.Pereira@va.gov.
Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1.
Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below.
Point of Contact: Rosangela Pereira, Rosangela.Pereira@va.gov
File details come from the government source that posted it. Updated .