Floor Layout.pdf
PDF 394 KB Posted
- Solicitation number
- 36C24125Q0702
About this file
This floor plan layout document depicts a comprehensive architectural blueprint for a Department of Veterans Affairs medical facility, specifically Building 1 at the Northampton VA Medical Center. The detailed drawing shows a fully sprinklered floor plan with multiple interconnected corridors and rooms, including treatment rooms (numbered 1103-1153), exam rooms, offices, staff facilities, patient areas, and support spaces like mechanical rooms, electrical rooms, and utility closets. The floor plan includes precise room measurements, room numbers, and a room description legend, providing a complete spatial overview of the facility's interior design and functional layout.
The blueprint is associated with a federal contract opportunity (Solicitation Number: 36C24125Q0702) for ACRE PAC System Upgrades and IDS System Relocation, which involves installing 12 reader boards, connecting to an updated PAC system, moving an Intrusion Detection System, installing 10 single-door electronic locks, and performing work within a 40-day performance period. The project is a small business set-aside with a NAICS code of 238210 and a small business size standard of $19.0 million, with quotes due by August 1, 2025, at 4:00 PM EST, to be submitted electronically to the contracting officer.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| PAC System Installation and Intrusion Detection System Relocation RFIs.docx | DOCX document | |
| 36C24125Q0702_1.docx | DOCX document | |
| 36C24125Q0702.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
- - Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseDESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Approved Date:
Approved Title:
Approved Name:
GR
AP
HI
C
SC
AL
E:
1/
4"
1' -0
4' 2'
1' 8'
0'
GR
AP
HI
C
SC
AL
E:
1/
2"
1' -0
2' 1'
6" 4'
0'
GR
AP
HI
C
SC
AL
E:
1/
8"
1' -0
8' 4'
2'
GR
AP
HI
C
SC
AL
E:
3/
8"
1' -0
4' 2'
6'
1' 6"
GR
AP
HI
C
SC
AL
E:
3/
4"
1' -0
2' 1'
6" 3'
0' 3"
GR
AP
HI
C
SC
AL
E:
1"
1'
-0
2' 1'
1/2
0'
GR
AP
HI
C
SC
AL
E:
3"
1'
-0
1' 6"
3" 0'
9" 11 2"
GR
AP
HI
C
SC
AL
E:
1-
1/2
1' -0
2' 1'
6" 0'
3"
# Date:Revision Description:
SCALE:01 BUILDING 1 LEVEL 1
1/16" = 1'-0" GRAPHIC SCALE:
1/16" = 1'-0"
16'8'4' 32'0 2'
B1-01
WITHOUT
FURN
EXPANSION JOINT
UP
DN.
DN
EXIST. STAIR
S-102
ELEV.
M101
GARAGE
EXIST. STAIR
S-100
EXIST. ELEV.
M100
POLICE
TREAT
TREAT
TREAT
MH VIEW
MH WAITING
TREAT
TREAT
TREAT
TREAT
OFFICE
SUPPLY
STAF TLT
PATIENT
EFFECTS
TREAT
CHECK-IN/OUT
PAT. TLT
EXAM
EXAM
PAT. TLT
STAFF TLT
EXAM
EXAM
EXAM
EXAM
1135 CONSULT
EXAM
PROCEDURE
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
PCMHI EXAM
CONSULT
EXAM
EXAM
EXAM
ACUP.
1151 ACUP.
CHIRO.
PROCEDURE
SHAREDSHARED
APPT.
IT CLOSET
PAT. TLT
1145 LOADING
DOCK
C106
CLEAN
UTILITY
MEDS
MEDS
ELEC.
E100
WAITING
VEST.
PUB TLT
1101C
PUB TLT
1101D
BARI TLT
1101A
PUB TLT
1101B
CORRIDOR
C101
TLT
1154A
PATIENT CORRIDOR
C105
PATIENT CORRIDOR
C103
ELEC
E101
LINEN
TOILET
1141A
CLOSET
Exist. Drum
UTWBBF162366
AED
AE
D
UP
1-PC-8
1-PC-9
THIS WINDOW
WALLED OFF
1265B
111 SF
1-TC-3
1-FC-2
1-EL-3
1-PC-6
1-FC-1
1218A
33 SF
1-PC-7
1256C
30 SF
1265A
10 SF
EXPANSION JOINT
OFFICE
97 SF
COPY
33 SF
OFFICE
104 SF
OFFICE
106 SF
OFFICE
116 SF
OFFICE
97 SF
OFFICE
95 SF
OFFICE
102 SF
STORAGE /
FUTURE WC
73 SF
OFFICE
149 SF
OFFICE
210 SF
OFFICE
97 SF
OFFICE
115 SF
OFFICE
93 SF
OFFICE
168 SF
STORAGE /
FUTURE WC
77 SF
MECHANICAL RM
1-ME-2
169 SF
OFFICE
108 SF
SHELL SPACE
140 SF
LOCKERS
1003A
85 SF
STAFF BREAK
316 SF
CONFERENCE
296 SF
SHARED SPACE
125 SFREST RM
90 SF
HSKP
90 SF
LEARNING CENTER
1620 SF
CREATIVE
THINKING RM
635 SF
GROUP RM
249 SF
WAITING RM
212 SF
250 SF
97 SF
144 SF
99 SF
80 SF
1265D
257 SF
177 SF
96 SF
148 SF
101 SF
1290A
155 SF
1290B
116 SF
119 SF
1277A
87 SF
129 SF
172 SF
94 SF
121 SF
116 SF
131 SF
163 SF
1272A
71 SF
121 SF
1270A
81 SF
1270B
61 SF
119 SF
122 SF
STAIR
1-PC-10
CORRIDOR
C100
1254A
23 SF
HK
73 SF
34 SF
36 SF
STAIR
RECEPTION
131 SF
114 SF
183 SF
1-MC-3
174 SF
87 SF
107 SF
153 SF
136 SF
225 SF
84 SF
103 SF
153 SF
136 SF
225 SF
114 SF
80 SF
175 SF
77 SF
171 SF
110 SF
EXAM
195 SF
114 SF
124 SF CONSULT
1257A
107 SF
HALLWAY
1255A
58 SF
WAITING
AREA
106 SF
CO
RR
ID
OR
C1 0?
-1 CORRIDOR
C10?-2
650 SF
181 SF
159 SF
94 SF
142 SF
1238A
57 SF
107 SF
214 SF
103 SF
164 SF
85 SF
97 SF
95 SF
197 SF
130 SF
87 SF
39 SF 1233A
42 SF
STAIR
ON CALL
146 SF
CO
RR
ID
OR
1 S
F
STAIR
235 SF
1071A
116 SF
90 SF
134 SF
165 SF
124 SF
131 SF
261 SF
1084A
59 SF 1083
32 SF
38 SF
123 SF
138 SF
135 SF
178 SF
149 SF
1082A
62 SF
1-PC-5
129 SF
66 SF
1-PC-4
1-
PC
-3
1638 SF (AREA 1)
296 SF (AREA 2)
1090C
90 SF
1646 SF
1090B
136 SF
1090A
103 SF
1095A
118 SF
1095B
81 SF
140 SF
1254B
12 SF
49 SF
CO
RR
ID
OR
C1 0?
-4
24 SF
VENDING
115 SF
VESTIBULE
OFFICE
111 SF
STAFF TLT
137 SF
SOILED
UTILITY
HSKP
EXAM
TEAM WORK
C104
TEAM WORK
C102
EXAM
130 SF
MED EQUIP
100 SF
CHANGING
60 SF
CORRIDOR
1253A
440 SF
DN
DN
MRI TRAILER
ROOM DESCRIPTION LEGEND
ELECTRICAL ROOM
FIRE CLOSET
HOUSEKEEPING
PIPE CHASE
TELEPHONE CLOSET (IRM)
EL
FC
HK
MECHANICAL ROOMME
PC
TC
| Sheets and Views |
| B1-01 Without Furn |
File details come from the government source that posted it. Updated .