Attachment 1 SOW.pdf
PDF 537 KB Posted
- Attached to
- J063--CBOC Lock Replacement Federal contract opportunity
- Solicitation number
- 36C24124Q0130
About this file
This scope of work document outlines a project to replace mortise locks at a Veterans Affairs medical facility. The VA Central Western Massachusetts is procuring and installing Corbin Russwin mortise locks with dormitory function and deadbolts at 26 patient room doors in the primary care section of the Worcester Belmont Street Community Based Outpatient Clinic. The contractor will be responsible for procuring the locks, removing the existing locks and deadbolts, installing the new locks and reusing existing cylinders, filling abandonment holes, and coordinating all work with VA facility staff over a four month performance period. The related federal contract opportunity is a solicitation issued by the VA Veterans Health Administration VISN 1 to obtain these lock replacement services.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Questions and Answers.pdf | ||
| 36C24124Q0130_3.docx | DOCX document | |
| 36C24124Q0130_2.docx | DOCX document | |
| Attachment 4 852.219-75 VA Notice of Limitations on Subcontracting.docx | DOCX document | |
| Attachment 2 Price Schedule.xlsx | XLSX spreadsheet | |
| Combined Synopsis - Solicitation.docx | DOCX document | |
| Attachment 3 Past Performance Worksheet.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
October 13, 2023
SCOPE OF WORK
VA Medical Center Leeds, MA Procure and Change Locks at Patient Rooms Worcester
CBOC
Belmont St. Worcester, MA
1. GENERAL
The VA Central Western Mass is replacing all the mortised locks in the patient rooms at the Worcester, Belmont St. CBOC, to change the functionality to better serve the users and patients. This requires the procurement and installation of new Corbin Russwin mortise Ml2065 dormitory function single cylinder with deadbolt, Mortise lock x NSA trim x US26d satin chrome finish to replace the existing mortised locks and thumb-turn deadbolts for all the patient rooms in the clinic.
2. PROJECT SCOPE OF WORK
Work will consist of: Procurement of Corbin Russwin mortise Ml2065 dormitory function single cylinder with deadbolt, Mortise lock x NSA trim x US26d satin chrome finish for every patient room door in the primary care section of the Clinic. New locks will be provided with inside and outside occupancy indicators. Scope will include removal existing mortise lock and deadbolt and filling the existing deadbolt hole with filler plates on the side, edge and strike of the door.
Existing cylinders to be relocated from the inside on the existing locks to outside on the new locks. Provide submittal with Install all cylinders upon schedule approved by VA.
This includes the following tasks:
a) Meet with VA Facilities staff, review existing drawings and estimates, and perform field work necessary to determine required materials and equipment.
b) Provide of Corbin Russwin mortise Ml2065 dormitory function single cylinder with deadbolt, Mortise lock x NSA trim x US26d satin chrome finish locks with inside and outside occupancy indicators at 26 doors in the primary care section of the clinic.
c) All Cylinders shall be re used on new locks. Cylinders to be re installed on outside of door.
d) Remove existing mortised locks/deadbolts (26) from primary care section of clinic and fill abandoned holes with filler plates.
e) Work will be in accordance with applicable VHA, OSHA, EPA, and Mass DEP standards and regulations. Requirements for OSHA to be completed by contractor.
f) Installation and any site visits shall be scheduled at least 72 hours in advance with VA Facilities Management. All work is expected to occur during business hours (7Am to
5:30PM)
g) The performance period for this work is 4 months after receipt of order.
h) The A&A requirements do not apply, and that a Security Accreditation Package is not required.