RFI 518-23-320 Bldg. #78 Ambulatory Chiller Replacement.docx

DOCX document 13 KB Posted

Attached to
Z1DA--518-23-320 Bldg. #78 Ambulatory Chiller Replacement
Solicitation number
36C24124B0012
Issued by

About this file

This document contains responses to questions regarding a request for information (RFI) for the replacement of an ambulatory care packaged unit/rooftop unit (RTU) at Building 78 of a Veterans Affairs medical center. The existing unit is a 50FY-074BHA500EA model manufactured by an unknown brand. The goal of the project is to replace the unit in kind. Photographs and building plans are provided as attachments to specify the location and dimensions of the existing unit. The related federal contract opportunity is a sealed bid solicitation numbered 36C24124B0012 for the replacement project, to be awarded by the Department of Veterans Affairs Veterans Health Administration VISN 1. Responses to the RFI seek to clarify details of the existing unit to inform bids for the replacement.

View the file

Other files

File Type Posted
RFI 36C24124B0012 11 JAN 24.docx DOCX document
36C24124B0012 0004.docx DOCX document
VAAR 852.219-75.docx DOCX document
36C24124B0012 0003.docx DOCX document
518-23-320 Aerial Photo - Bing.pdf PDF
78-6 Exterior Elevations _ Building Sections (13202).pdf PDF
36C24124B0012 0002.docx DOCX document
Sign In 518-23-320.pdf PDF
518-23-320 Building 78 Ambulatory Chiller Replacement - Site Photos.pdf PDF
36C24124B0012 0001.docx DOCX document
36C24124B0012.docx DOCX document
SOW Amb Care 02.docx DOCX document
WAGE-RATES 02.docx DOCX document
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RFI response to 518-23-320 Bldg. #78 Ambulatory Chiller Replacement.

Response to Question 1 - Please clarify the Model No of the Chiller. There is no information available concerning this unit, who is the Manufacturer and the specifics that the VA wants.

Answer: Please response to Question 2 below.

Response to Question 2 - Please clarify the existing model no. Packaged Unit/RTU Model # 50FY-074BHA500EA and the manufacturer. Please provide capacity of the new unit. Please provide photos of the existing installation and height of the building.

Answer: The goal of this project is to replace the existing unit in kind. Please see attached PDF File “518-23-320 Building 78 Ambulatory Chiller Replacement - Site Photo” for manufacturer, model number and photographs of existing unit. Please see the attached record plan “78-6 Exterior Elevations & Building Sections (13202)” for elevation and sectional view of roof top area where unit is located and height information. Please see attached PDF File “518-23-320 Aerial Photo – Bing” for an aerial photo identifying unit.