MHEOC Checklist.xlsx

XLSX spreadsheet 110 KB Posted

Attached to
C1DA--631-22-010 Renovate Building 6 (Cascades) for Acute Inpatient Mental Health
Solicitation number
36C24123R0074
Issued by

About this file

This sources sought notice requests letters of interest from firms for architect and engineering services related to renovating a 9,500 square foot building on a VA campus to create a Psychosocial Residential Acute Mental Health Inpatient space. The renovation includes interior renovations, masonry repairs, window repairs and abatement, and adding an egress corridor. The NAICS code is 541330 for Engineering Services and the small business size standard is $22.5 million average annual revenue. The notice requests information on company name and socioeconomic status, team composition and percentages of work, experience with mental health and VA design requirements, experience with state historical offices and renovating historical buildings, and any additional capability statements by February 13, 2023 to Chelsea Rodrigue.

View the file

Other files

File Type Posted
36C24123C0111_1 Award Notice.pdf PDF
SOW AE Renovate Cascades Building for Acute Mental Health.pdf PDF
B6 Concept Sketch.pdf PDF
36C24123R0074 0003.docx DOCX document
1061_D_2021-02-16 Legionella Prev.pdf PDF
Past Performance Questionnaire.pdf PDF
36C24123R0074 0002.docx DOCX document
36C24123R0074.docx DOCX document
SOW AE Renovate Cascades.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Background

Background:

The idea of an Environment of Care Checklist to reduce the risk of suicide and para-suicidal behaviors grew out of the Patient Safety Workgroup, a subcommittee of the Performance Measures Workgroup. Dr. Ira Katz (Deputy Chief Patient Care Services Officer for Mental Health) asked us to first review the Root Cause Analysis Database to see if inpatient suicides and parasuicidal behaviors were in fact related to environmental factors. The results revealed that 54% of inpatient suicides and suicide attempts in VA occurred on inpatient psychiatry units or detox units. In addition, approximately 70% of the events were either hangings, cutting with a sharp object or drug overdoses, with hanging the largest category. Virtually all of the hangings used some environmental anchor that could be modified to reduce the risk of harm; and 39% of the cutting incidents used razor blades.

Based on this report, it made sense to develop an environmental checklist for use in VA mental health units. Dr. Katz approved of this course of action.

A national committee was formed to develop the checklist with the following charter:

Committee Charter: To develop a consensus environmental checklist for the purpose of reducing environmental factors that contribute to inpatient suicides, suicide attempts, and other self-injurious behaviors. A secondary product of the committee will be to add items to the checklist that consider environmental factors that reduce employee safety on mental health units. The checklist will not address procedures for determining whether a patient is at risk for suicide or reducing the risk of suicide through various mental health treatments. The focus will be on the environmental factors contributing to patient and staff safety. We will do this by reviewing existing checklists and adding to the checklists based on professional experience. The committee will also make recommendations for how to use the checklist in conducting environmental rounds on mental health units. This initiative is consistent with the Joint Commission patient safety goals and Dr. Katz's mental health initiatives within VHA as well as the current literature on prevention of suicidal behaviors (see Mann et al, Suicide Prevention Strategies: A systematic review. JAMA, 2005, v 294, 2064 -2074).

Committee Members:

Peter D. Mills Ph.D. Associate Director NCPS Field Office
Shoshana Boar MS Research Assistant NCPS Field Office
Joseph DeRosier PE, CSP, Program Manager, NCPS
Noel Eldridge MS, Executive Assistant NCPS
B. Vince Watts MD, Psychiatry and Patient Safety VAMC White River Junction.
Eunice Steimke VISN 6 Patient Safety Officer
Terry Sanders VISN 21 Patient Safety Officer
Jim Rice VISN 11 Quality Management Officer
Mike Miller MD VISN 1 CMO
E. Sam Rofman MD, Mental Health Service Line Manager VISN 1
Katherine Kotrla MD, Mental Health Service Line Manager VISN 17
Hedy Stump RN - Associate Chief Nurse for Behavioral Health, Lebanon VAMC
David P. Klein, P.E., VHA Fire Protection Program Manager
Ron Gurrera MD, Chief of Psychiatry VA Boston HCS
Phil Kleespies Ph.D., Psychologist VA Boston HCS
Karen Bassett, RN, VA Boston HCS.
Dan Colagrande (183A) VACO – Architect
Del Ng, Chief Engineer, VA Palo Alto HCS
In 2013 NCPS updated the checklist. The charter for the update committee was to review the MHEOCC to ensure that it continues to be in compliance with VA codes, and to add any improvements that will make it a better tool for the field. The overarching goal is to continue to reduce suicide attempts and completions on the mental health units in VHA that use the MHEOCC to review their environment of care. As with our first charter, the focus of this committee will be reducing environmental factors that contribute to inpatient suicides, suicide attempts, and other self-injurious behaviors; and factors that reduce employee safety on mental health units. The checklist will not address procedures for determining whether a patient is at risk for suicide or reducing the risk of suicide through various mental health treatments.
Committee Members for the review committee were:
Peter Mills, NCPS
David Sine, NCPS
Vince Watts, NCPS
Lori King, NCPS
David P. Klein, VHA Fire Protection Program Manager
Dan Colagrande (183A) VACO – Architect
Linda Bond, Director, Acute Mental Health, Louis Stokes VAMC
Loren Wilkenfeld, Associate National Mental Health Director, Integrated Care
Gayle Iwamasa VACO Mental health operations.
James McCarthy, Nurse Manager, Mental Health Albuquerque VAMC
Mark Fossett, Engineering VACO
David Sabol, Chief of Engineering Service, Louis Stokes Cleveland, VAMC
Rosemary Daniels RN, QM and Patient Safety, Cleveland VAMC
Robin Anderson-V7 Patient Safety Officer
Anna Louise Scandiffio-V5 Patient Safety Officer
Catherine Rotolo, Psychiatry, Social Worker, Cleveland VAMC
Albert Henderson RN from Albuquerque
References about the checklist are as follows:
Watts, BV, Shiner, B, Young-Xu, Y and Mills PD. Sustained Effectiveness of a Mental Health Environment of Care Checklist to Decrease Inpatient Suicide. Psychiatric Services. Epub 2016 Nov 15
Watts BV, Young-Xu Y, Mills PD, DeRosier, JM, Kemp J, Shiner B & Duncan WE. An Examination of the Effectiveness of a Mental Health Environment of Care Checklist in Reducing Suicide on Inpatient Mental Health Units. Archives of General Psychiatry. 2012 June: 69(6): 588-92
Mills, PD, Watts, BV, Miller S, Kemp J, Knox K, DeRosier J, and Bagian JP. A checklist to identify inpatient suicide hazards in Veterans Affairs hospitals. The Joint Commission Journal on Quality and Patient Safety, 36 (2): 87-93, Feb. 2010.
In May 2017 a Directive will all policy and procedures related to the MHEOCC was released in VHA. VHA Directive 1167. Available at:
http://vaww.ncps.med.va.gov/Guidelines/mheocc/1167_D_2017-05-12.pdf

MHEOCC Transmittal Letter Page &P of &N http://vaww.ncps.med.va.gov/Guidelines/mheocc/1167_D_2017-05-12.pdf General Instructions

Mental Health Environment of Care Checklist

VHA National Center for Patient Safety

Department of Veterans Affairs

Version 09-30-2020

Should you require further information, please contact Peter Mills, PhD from the National Patient Safety Center at peter.mills@va.gov, Gayle Iwamsa Ph.D, Office of Mental Health Operations and Suicide Prevention - Gayle.Iwamasa@va.gov.

General Instructions for the Mental Health Environment of Care Checklist
This spreadsheet contains the Mental Health Environment of Care Checklist (MHEOCC) along with a protocol for using the checklist and a list of references regarding mental health environment of care. Please review the protocol for information on forming a Multidisciplinary Safety Inspection Team (MSIT) and using the checklist to identify environmental safety concerns on locked mental health units and Emergency Departments. Once environmental concerns are identified the protocol guides users in rating the level of risk, developing a corrective action plan, and monitoring progress. Environmental concerns that are rated at the highest level of risk should be corrected within 24 hours. Identified environmental concerns rated at a lower level of risk should be addressed as soon as possible based on a cost-benefit analysis and available funding.
Criteria that are only applicable to NEW mental health care units (including those units undergoing renovation that require use of Chapter 18 of the Life Safety Code) have been identified with the designation "Only New Units." Existing space should be modified to meet ALL of the remaining criteria.
1. POLICY:
Please refer to VHA Directive 1167: MENTAL HEALTH ENVIRONMENT OF CARE CHECKLIST FOR MENTAL HEALTH UNITS TREATING SUICIDAL PATIENTS (Date: May 12, 2017) for all policy and procedures related to the MHEOCC, available at:
http://vaww.ncps.med.va.gov/Guidelines/mheocc/1167_D_2017-05-12.pdf

MHEOCC, Instructions Page &P of &N http://vaww.ncps.med.va.gov/Guidelines/mheocc/1167_D_2017-05-12.pdf General Criteria

Version 09-30-2020
Mental Health Environment of Care Checklist General Criteria
Ques. No.ePSAT cross reference numberSite / ItemQuestions / CriteriaRationale / Assessment MethodsN/AMetPartially MetNot MetComments
FLOORS
17.2.13.1.1Floor covering1.a. Are floor coverings free of tripping hazards?
1.b. Are floor coverings secured to the floor?Floor coverings should be tightly sealed to the floor, in good repair without tripping hazards, and not easily torn or dislodged.Updated March 2013
27.2.13.1.2HVAC ventsAre floor-mounted HVAC vents removed?Floor-mounted HVAC vents should not be used. There should be no exposed and accessible HVAC equipment such as floor mounted fan coil units, radiators, convectors, or finned tube radiation. Note these vents can be used as a weapon and as a tie-off point for a ligature. Until they can be removed the risk must be mitigated and this mitigation noted in the tracking sheet.Updated March 2013
37.2.13.1.3Thresholds3.a. Are door thresholds secured to the floor and no higher than 3/4 inches above the floor?
3.b. Are door thresholds secured using tamper resistant anchors or fasteners?Avoid thresholds where possible. Look for other projections on the floor that could be tripping hazards or could be removed easily to be used for self-harm or as a weapon.
WALLS
47.2.13.1.4Wall covering or paint4.a. Are wall coverings and paint non-toxic?
4.b. Are wall coverings secured to the wall and not peeling?Non-toxic wall paper, glue, and paint should be used. (Note that most newer wall coverings, glues and paints are non-toxic). Paint and wall paper should not be peeling.
57.2.13.1.5Pictures5.a. Are picture frames and coverings made of non-breakable material?

5.b. Are picture frames secured to the walls using tamper resistant screws or anchors?

5.c . Are picture frames hung so that they cannot be used for hanging?No glass coverings; no sharp edges; wood frames only, no metal frames; secured to the wall; may also be frameless; smaller is better; safe pictures are encouraged for milieu.Updated March 2013
67.2.13.1.6Electrical outlets6.a. Are the number and locations of electrical receptacles in the room adequate?

6.b. Are receptacles and switches covered by metal plates that are secured by tamper resistant screws?

6.c. Are the electrical boxes flush mounted?

6.d. Are all receptacles provided with GFCI protection? GFCI-protected outlets, adequate number of outlets, short electrical cords. Equipment with cords should be located close to the wall outlet; cords should be too short to loop around the neck and secure to an anchor point for hanging. If the outlet will be used for medical equipment it should be tamper resistant but not GFCI as GFCI outlet may trip and shut off the equipment (added August 2008). As of August 2008 there are GFCI-Tamper Resistant outlets that should be used.

http://www.cooperindustries.com/content/public/en/wiring_devices/products/receptacles/residential/aspire/aspire_tamper_resistant_gfcis_9566tr_9569tr.html?_ga=2.252483850.203627272.1561398478-1792284201.1561398478

Link added June 2019 7 7.2.13.1.7 HVAC vents 7.a. Are HVAC vents flush with the wall?

7.b. Are HVAC vents secured with tamper resistant screws?

7.c. Are louvers designed so that they cannot be used to secure any item that might be used to attempt suicide by hanging?

7.d. Are vents designed without sharp edges to prevent self-harm?Vents should be flush with the wall and secured with tamper resistant anchors; vents or registers must be designed so that they cannot be used as anchor points for hanging. Vents should not be able to be removed and used as a weapon or for self-harm.Updated March 2013
87.2.13.1.8Edges of wallsAre corner guards present on all wall edges?
Are corner guards secured with tamper resistant screws?Wall edges and corners should be protected by corner guards.
97.2.13.1.9Vinyl BaseboardIf used, is vinyl baseboard secured to the wall so that it cannot be easily removed and used as a weapon?Vinyl baseboard is used in many buildings. It should be secured to the wall. Look for sections that may be loose or have gaps making it easy to remove. If removed it could be used as a weapon.
107.2.13.1.10Surface wire moldHas all surface-mounted wire molding been removed?In older buildings, it is not unusual for wiring to newer receptacles to be run in surface-mounted wire molding. Ideally, wire should be run inside of the wall and out of sight. Surface-mounted molding could potentially be used as an anchor point and should be replaced with flush wall-mounted receptacles. Prior to being replaced, any surface-mounted wire molding must be secured tight to the wall with no gaps and secured with tamper resistant screws.
117.2.13.1.11Corner MirrorsCorner mirrors are secured with tamper resistant screws and are flush mounted so that they will not support a rope or material for hanging.Corner mirrors may be necessary for safety, but must not provide an anchor for hanging and must be made of non-glass material.
127.2.13.1.12Other items on the wall12.a. Are bulletin boards, message boards, posters, telephones, door stops, exit signs, and lights secured using tamper resistant screws?

12.b. Alcohol dispensers should not be on the walls in patient areas? Look at each item. All items must be secured to the wall in a manner that prevents removal or use as a weapon or for self-harm. It must be flush with the wall or beveled in a manner so that it cannot be used as an anchor for hanging. If lights are on the wall, the glass bulbs should not be easily accessed.

Alcohol based gels and foams may be consumed by patients and therefore should not be accessible to them. See question #19 below for guidance on sprinklers.

Updated March 2013

137.2.13.1.13Other projectionsAre items projecting from the wall, even if otherwise considered a safety item, designed so they cannot be used for harm of self or to harm others? For wall-mounted sprinklers, see sprinkler criteria under Ceilings section.Cords should be too short to use to wrap around a neck and hang from any securing point (maximum of 12 inches). Wall telephones should only be in locations that can be continuously observed by staff and the cord between the telephone base and the hand set should be as short as practically possible. Hooks and hangers, even if structured with safety features, should be evaluated for risk to others. Drinking fountains should be secured to the wall and visible to staff.
13.1Tamper Resistant ScrewsAre all tamper resistant screws checked quarterly to ensure that they are still tight and do not create an anchor point for hanging?Tamper resistant screws can become loose making them easy to remove.Added March 2013
147.2.13.1.14Thermo-statsAre wall mounted exposed room thermostats removed from patient areas?No wall mounted exposed room thermostat in patient areas. Use duct mounted temperature sensor programmable from a remote control panel or (if necessary) recessed wall mounted aspirating type room thermostat with a tamper resistant perforated cover.
CEILINGS
157.2.13.1.15Surface15.a. Are ceilings that are in areas not in the direct line of sight of the nursing station constructed of solid materials such as plaster/lath, gypsum board, or a metal pan system that requires the use special tools for removal?

15.b. Are ceilings free of hanging objects such as plant hangers and wind chimes?

15.c. Check all ceiling tiles and access panels semi-annually to make sure they are still secure and that patients cannot access the ceiling. Added November 2016.The space above a ceiling will almost always contain pipes, conduits, ductwork, and other building features that could be used as an anchor point for hanging. In areas accessible to patients and not continuously observable by staff (e.g., patient bed rooms, day rooms), ceilings should be solid or of a rigid, locking metal tile. Acoustical tile lay-in ceilings are not acceptable in these areas, even if the tiles are locked in place. There should not be items hanging from the ceiling since these will present anchor points.
167.2.13.1.16Access DoorsAre access doors in solid ceilings locked using a key or special tool to prevent unauthorized access and secured to the ceiling using tamper resistant fasteners?Access doors are needed to access electrical and mechanical equipment above the ceiling. Patients having access to this space may harm themselves or others or use the space for storing contraband items. It is critical that these access door be locked at all times and the locks are routinely checked. All access doors should be flush with ceiling to prevent being used as an anchor point or being bent into a sharp edge.
177.2.13.1.17Light fixturesAre light fixtures flush mounted in the ceiling, tamper resistant, and provided with break-resistant panels or covers and designed so they cannot serve as an anchor point for hanging?Light fixture coverings should be secure and of break-resistant material so that bulbs cannot be accessed for self harm or harm to others. Tamper resistant screws/attachment devices should be used, and the light fixtures should not create an anchor point.
187.2.13.1.18HVAC vents18.a. Are vents in the ceiling flush mounted with the ceiling surface and secured with tamper resistant fasteners?
18.b. Are vents in the ceiling designed so they cannot serve as an anchor point for hanging?Louvers can be used as an anchor point; mesh or grates are preferable or the louver should not support weight. Edges should be caulked with tamper resistant caulk to avoid being used as anchor point or sharp.
197.2.13.1.19SprinklersAre fire sprinklers the institutional type that cannot be used as an anchor point for hanging?Institutional sprinklers should be used for sprinklers installed on the walls as well as the ceiling. An institutional sprinkler is designed to resist tampering and to not provide an anchor for hanging; the fusible element is designed to breakaway rather than support the weight of a person. See http://www.reliablesprinkler.com/sprinklers_products.php?cid=28
19.17.2.13.19.01Access Point for Wireless ComputersAre all access points for wireless computers covered with a shatter-proof cover that cannot be pulled down from the ceiling?Wireless access points cannot be installed in patient sleeping rooms or patient bathrooms; the wireless access points are authorized to be installed in the corridors, day-room, computer rooms and nursing stations (For questions on any other areas within mental please contact Peter.Mills@va.gov). All wireless access points on mental health units must be protected by a shatterproof cover that is installed and secured with tamper resistance screws. Tamper resistant screws used for the covers should be of the TORX or Allen head type (tools typically carried by IT personnel) for maintenance access purposes. The access point and the cover will be secured in such a way to prevent pulling away from the ceiling.See: https://vaww.sde.portal.va.gov/sites/fo/svcs/ectm/fis/wireless/Shared%20Documents/Important%20Docs%20for%20Sites/Installation%20Docs/Mental%20Health%20Areas%20Installation%20Guide.pdf
WINDOWS
207.2.13.1.20Panes20a. Does the glazing material in windows comply with VA specifications (5/16 inch laminated safety glazing for general areas and 7/16 inch laminated safety glazing for high-security areas such as seclusion rooms? - updated January 2013)

20.b. If windows open, are they restricted so that the maximum opening is 4 inches or locked to prevent them from being opened by a patient? Do staff know the location of the key need to unlock the window and is it accessible to them if it is needed? Updated November 2016.

20.c. Are windows inspected at least semi-annually to ensure locking mechanisms have not been compromised (added 9/01/2009) See below for glazing requirements from VA Master Specification Section 08810, Glass and Glazing. If the unit was designed as a mental health unit it is likely that the glazing meets the requirements. If the unit was converted from a different use, the glazing may not meet the requirements for mental health units. Consult with facility Engineering staff regarding use of Section 08810.

For Glazing Specifications please see: Section 08 80 00, Glazing @ http://www.cfm.va.gov/TIL/spec.asp#08

Security screens, if placed over external windows, are also an acceptable mitigation. (August 2008)
20Panes, continuedExcerpted from VA Master Specification Section 088000:

1. Mental health and behavioral science service for psychiatric, alcohol, and drug dependency treatment areas require "Security Glazing" assemblies, resistant to breakage and use as weapons.

2. Security (seclusion) rooms, including room doors, use 11 mm (7/16 inch) laminated clear glass, clear heat strengthened glass clad polycarbonate, or clear tempered glass clad polycarbonate.

3. For patient ward glazing use laminated assemblies of tinted, heat strengthened, clear, clear tempered, or clear heat strengthened glass.

4. Specify optional glazing of clear heat strengthened glass clad polycarbonate, or clear tempered glass clad polycarbonate for 11 mm inch (7/16) thick laminated glass.

Please see: Section 08 80 00, Glazing @ http://www.cfm.va.gov/TIL/spec.asp#08 21 7.2.13.1.21 Window frames 21.a. Are window frames designed to prevent them from being broken by a patient?

21.b. Are the windows frames free of projections or holes that could serve as an anchor point for hanging? Frames should be tamper resistant and shatter resistant and tested to make sure that they cannot be broken apart.

The following are the performance requirements for window frames in mental health units:

“Behavioral Health Interior Access Windows: Provide interior access windows designed to meet the 2711 Newton meters (Nm) (2000 ft-lb.) simulated human impact test in accordance with AAMA 501.8-13.”

Updated November 2016
227.2.13.1.22Window coverings22.a. Are window covering designed so they cannot be used for hanging?
22.b. Is the hardware supporting the window covering designed and installed such that it cannot serve as an anchor point for hanging and secured with tamper resistant fasteners?Shades, or blinds inside of window panes are safest choices. There should be no cords or ropes attached and curtains should not be used. Hardware should be flush with the wall so that it can’t be used to secure a noose. It should also be tamper proof to prevent it being removed and used as a weapon or for self harm.
DOORS
2313.00-1.00-38.00Corridor Doors23.a. Do corridor doors to patient sleeping rooms have the ability to swing out into the corridor or have a wicket door? (Only New Units)

23. b. If a gasket or sweep is used, it should be cut into sections that are short enough (e.g., 12 inches or less) so that if the gasket or sweep is removed it cannot be used for self harm.

23. c. Do corridor doors to patient sleeping rooms have an over-the-door alarm? Updated November 2019

23. d. Are all over the door alarms checked semi-annually to make sure they are still working properly? Updated November 2019 Because of Life Safety Code limitations regarding door swing into the corridor and corridor obstruction from a fully-opened door, corridor doors have traditionally been designed to swing into the room. For corridor doors in new construction it is recommended to install a door and frame assembly that will permit the door to swing in both directions. Normal operation could be door swing into the room, but if necessary (e.g., patient barricaded inside the room), staff could release the door stop so that the door could swing into the corridor. NOTE: The use of a wicket door (a door within a door) is also acceptable in both new and existing construction.

Refer to the Life Safety Code (NFPA 101) for the complete set of door requirements. Note: The 2012 Edition of the Life Safety Code has been changed (See 18.3.6.3.9.2 below) based upon a proposal by the VA to assist in the hardware selection for psyche facilities. It would essentially allow the option of using a roller latch (not previously permitted in new construction) along with no door handle to assist in meeting the Life Safety Code corridor door requirements. Contact: peter.a.larrimer@va.gov if you have questions.

Please Note: We have not been able to find a corridor door that completely eliminates all suicide hazards. Corridor doors must also be designed to limit the transfer of smoke so they cannot be cut down.

A Memo from 10N dated May 10, 2019 required all sleeping room corridor doors to have an over-the-door alarm by January 1, 2020.

23.1. 7.2.13.11.23.1 Interior Doors that do not need to limit the transfer of smoke 23.c. Are doors that are within rooms and that open to other in-room areas such as bath/shower/toilet areas (i.e., not corridor doors) designed to eliminate anchor points?

23. d. Are thick wooden cut-down doors removed and replaced by SER doors, soft suicide prevention doors or break-away curtains?

23. e. Are interior doors are inspected semi-annually to ensure that the top hinge is intact and that there are no anchor points?

Updated November 2016 For doors NOT opening to the corridor, the preferred door design is an angled top (hinge side higher) with an approximately 6-inch gap between the top of the door and the door frame. Doors that do not open to the corridor are not required to limit the transfer of smoke, so the dimension of the gap between the door and the frame is not specified. Doors to wardrobe cabinets or closets should be removed and shelves should replace rods and hangers.

Even with an angled top door, the presence of door latching hardware, including roller latches, provides an accessible anchor point to patients when ligatures are pinched between the door edge and the door frame.

Another potential anchor point may exist above the continuous (piano) hinge of an angled top door. While a continuous hinge is recommended over standard door (2 or 3 point) hinges, it is not without risk. The continuous hinge must have a “hospital cut” at the top providing a sloped surface for the entire top surface of the door.

If cut down doors or SER doors are installed in locked mental health units, then do one of the following:

a) Remove latching door hardware, (positive latching or roller latches) on cut down doors or SER doors. Fill any holes in the doors to remove potential anchor points. Trim back the latching edge of the door to create a gap of approximately 1 inch between the door and the door frame that will not permit a ligature to be pinched between them. Install a soft gasket material to the latching edge of the door that is cut into lengths not exceeding 12 inches.

or

b) Replace cut down doors equipped with any type of latching door hardware with soft break-away doors for bathrooms and showers.

See Patient Safety Alert AL10-03 (10/06/2009) 24 7.2.13.1.24 Hinges 25.a. Are swinging doors provided hardware that reduces the risk of the hardware being used as an anchor?

25.b. Are three point hinges designed and installed so they do not protrude providing an anchor point for hanging? Standard butt hinges, if used, must have a "hospital tip" that is beveled. Wherever possible use continuous piano hinges.

25.c. Are doors free of hold-open devices and self-closers that could be used as an anchor point for hanging? The dual-swing doors discussed in item 23 above are supported by a post at the top and bottom of the door and do not have hinges. Such hardware is acceptable as long as the gap at the top of the door is sufficiently small to reduce the risk that the post could be used as an anchor point. (Note it is not possible to completely eliminate the risk of a person threading a small lanyard around the post and using it to hang.) If piano hinges are used, it is recommended to use piano-type hinges that are flush-mounted to the door frame.

Spring loaded hinges are acceptable if the door is required to be self closing by a code or regulation.Updated March 2013
257.2.13.1.25Door hardware for corridor doorsIs the door latching hardware designed and installed to prevent it from being used as an anchor point for hanging?Hardware should be designed with a taper or a lever so a noose would slip off with the weight of a person. See Reference to Products for specific products.

Note: The 2012 Edition of the Life Safety Code has been changed (See 18.3.6.3.9.2) based upon a proposal by the VA to assist in the hardware selection for psyche facilities. It would essentially allow the option of using a roller latch (not previously permitted in new construction) along with no door handle to assist in meeting the Life Safety Code corridor door requirements.

See: http://vaww.ceosh.med.va.gov/01FS/Pages/firesafety.shtml

25.17.2.13.1.25.1Door StoppersAre door stoppers attached with tamper resistant hardware and designed to prevent self-harm or harm to others?We have had several reports of door stoppers that expose long sharp screws when removed, it is important to check door stopper to be sure they are not loose and cannot be used as weapons or for self-harm.Added March 2013
CLOSETS / SHELVES / RACKS
267.2.13.1.26Closets27.a. Are closets free of clothes rods? There should be no clothes rods of any kind in closets.

27.b. Are closets free of clothes hangers (plastic, wood, and metal)? (Added September 2010)

27. c. Are doors on closets or wardrobe cabinets removed? Clothing rods of any type can be used as a ligature point for hanging and can be used as a weapon.

Doors on closets and cabinets should be removed so that they do not provide an anchor point for hanging.

Spring-loaded hooks designed for mental health areas should be used in lieu of closet rods and hangers.

27 7.2.13.1.27 Shelves 28.a. Are shelves in closets secured with tamper resistant fasteners and designed so they cannot be used as an anchor for hanging?

28.b. Are heavy items on shelves placed low to the floor and secured in place to prevent them from being removed?

28.c. Is each shelf layer secured and not removable so that it cannot be pulled apart to be used as a weapon?If there is a television or other electrical or heavy item on the shelf, it should be secured so that it cannot be pulled off onto someone, and the electrical cord must be short and plugged directly into the electrical receptacle. Sets of shelves should be short or low in height (low profile) to prevent the patient from reaching the ceiling.
287.2.13.1.28Racks29.a. Are racks secured to the wall with tamper resistant fasteners?

29.b. Are racks designed so they cannot be used as an anchor point for hanging?

29.c. Are racks free of parts or pieces that can be removed and used as a weapon?Any racks must be flush with the wall and secured with tamper resistant screws.
FURNITURE
297.2.13.1.29Furniture – general considerations30.a. Is furniture secured or heavy enough to prevent it from being picked up and thrown or moved to block a door?

30.b. Is furniture designed to prevent it from being pulled apart or splintered to be used as a weapon for self-harm or harm to others? Examples of potential hazards are pieces of metal such as drawer roller assembly, or a part of a bed or chair that could be removed and used as a weapon.

30.c Is the furniture (e.g., chairs, stools, tables, beds, cabinets, shelves, desks) accessible to patients free of anchor points to prevent hanging? Are wheelchairs with anchor points are inaccessible to patients?

30.d Are floor guards on all furniture in the unit either a) attached to the furniture using tamper-resistant fasteners or b) removed from the furniture?

Furniture should be heavy and difficult to pick up and move; it should be made of wood or sturdy plastic; knobs and pulls should be designed to not support weight. Furniture should be low profile type so that it cannot be used by the patient to reach the ceiling.

Furniture should not have anchor points for hanging, or floor guards that can be removed by patients and used as a weapon or for self-harm.

Furniture in private areas such as bedrooms should have no anchor points. Heavy furniture should not be in bedrooms. Added November 2017.

Furniture, including wheelchairs, should be free of plastic, vinyl, or other materials that could be removed and used for suffocation or strangulation (Added March 2014).

29.17.2.13.1.29.1Furniture in private areas such as bedrooms and bathrooms.Furniture in private areas such as bedrooms and bathrooms should have no anchor points. Heavy furniture should not be in bedrooms or bathrooms.Furniture in private areas such as bedrooms should have no anchor points. Heavy furniture should not be in bedrooms or bathrooms. We have had several adverse events in which patients used heavy furniture as an anchor for attempted hanging. Added November 2017.
See:

http://vaww.office.ncps.med.va.gov/tools/pslog/edit.asp?id=937

PLUMBINGreports of adverse events in which patients used heavy furniture as an anchor for attempted hanging. Added November 2017
307.2.13.1.30Plumbing – not bathroom31.a. Are sinks secured to the wall or floor so that they cannot be easily moved?

31.b. Is the plumbing enclosed in a tamper-resistant enclosure to prevent access by patients?

31.c. Is under-sink storage secured?

31.d. Is the temperature of the hot water tested to ensure it will not cause a burn?

31.e. Do anchor points exist on the sinks or faucets (or other accessories)? (Added March 2012)

There should be no exposed piping or conduit in patient areas. The sink faucet should be a single unit with a round handle that is designed with a taper or a round lever so a noose would slip off with the weight of a person. A sensor type faucet is preferable since this has no lever. Hot water should be regulated so that it is 105 - 110 degrees F at the tap (see VHA Directive 2002-073, Domestic Hot Water Temperature Limits).

Sinks must not have any anchor points and the patient should not be able to hang from the sink itself. One design that achieves this is a vanity that extends from wall to wall. Added March 2013.

Faucets must also have no anchor points.

OTHER CONSIDERATIONS
317.2.13.1.31VisibilityIs the unit designed to eliminate blind spots? Note: In existing buildings alternate and equivalent methods must be in place (e.g., non breakable mirrors) to increase visibility.Some older buildings have configurations that result in hallways that are not visible from the nurses station. Any blind spots should be mitigated or addressed. Rooms that house patients on special watches should not have any areas that are not visible. Blind corners or hallway intersections should have a corner mirror (non-glass material) installed at the ceiling as discussed above.
327.2.13.1.32Chemicals and equipmentAre chemicals, including those in housekeeping carts, secured when not in use?

Are carts locked away when not in use? (January 2013) Can locks for storage cabinets on the unit be disabled by items that may be available to patients, such as plastic cards? (2014) All chemicals, housekeeping supplies and equipment, and maintenance carts and equipment must be secured or have someone in attendance.

33 7.2.13.1.33 Medical Equipment 34 a. Are devices such as blood pressure cuffs and other medical equipment kept inaccessible to patients? Also make sure that wheelchairs with anchor points are not accessible to patients.

34 b. Have patients with assistive devices been evaluated for their risk for using the device as a weapon or to barricade themselves in a room? Blood pressure cuffs can be placed around the neck and inflated, or the cords and hoses can be used for self harm or to harm others. Other medical equipment may present dangers also. These items should be kept in locked rooms or where a staff member is in attendance.

Practitioners should assess a patient’s suicide and fall risks, the need for assistive devices and the danger of the assistive device, on a case-by-case basis. The practitioners and the treatment team must weigh the risks vs. benefits for each patient and the environment as a whole. This assessment needs to include, at minimum, the patient’s risk for falls, the patient’s risk for suicide, aggression or aggressive behaviors on the part of the patient or other patients within the unit, and the ability of the device to barricade a door or be used as a weapon. It is suggested that physical therapy be consulted, as needed, to assist in developing an interdisciplinary plan of care that minimizes risk for injury from falls, self-harm behavior or of harm to others. Less complex options for patient mobility could be found to be more applicable (e.g., don’t permit use of a walker if a quad cane is equally effective and safe for the particular patient). Note that reassessment during a patient’s stay will be required if the patient’s behavior or suicidal status changes (e.g., if the patient become aggressive) or if the environment changes. Updated June 2011

See Patient Safety Alert: AL 11-06

33.1 7.2.13.1.33.1 Medical Equipment 33.1 a. Is all medical equipment, such as CPAP machines, blood pressure cuff, Oxygen tubing, and medical beds under direct line-of-sight observation by staff?

Added June 2018

Medical equipment can be used for self-harm. Medical beds and wheelchairs have anchor points for hanging. CPAP machines and oxygen tubing can be used for hanging or strangulation.

Direct line-of-sight observation is defined as constant observation of the patient by staff. Staff can observe multiple patients, but must remain in the area with patients, such that if a patient needs immediate intervention, the staff member can intervene and call other staff to help as needed. Observation by cameras cannot substitute for direct line-of-sight observation.

See: VHA DIRECTIVE 1167 Added August 2019:

NOTE: As of August 2019 it is acceptable to have wheelchairs, without high bars or modifications that increase the hanging risk, to be used by patients who are assessed to be at low-risk for suicide on mental health units at night with 15 min checks. Patients must be in single rooms (or double rooms where both occupants have wheelchairs and are assessed to be at low risk for suicide) close to the nursing station so that staff can ensure that other patients do not have access to the wheelchairs at night. During the day patients in wheelchairs should be under direct line-of-sight observation (this is keep other patients from accessing the wheelchair for self-harm or to harm others).

34 7.2.13.1.34 Trash bags Are trash cans in areas accessible to the patients free of plastic bags that can present a suffocation hazard?

All trash cans should be collapsible so they cannot be used to stand on. (Updated January 2013)The trash cans should be lined with paper liners. Also see question number 42.1.
357.2.13.1.35CordsIs the area free of unnecessary cords?If cords are present, they should be 12 inches or less. Cords of any length are not recommended for seclusion rooms.
367.2.13.1.36Weapons37 a. Is the area free of lamps, steel trash cans, and other items that could be used as weapons?

Inspect ward and patient rooms. Also inspect for devices with detachable pieces that could be used to harm themselves or another e.g., wheelchairs with detachable pieces (e.g., arm rests, anti-tip parts, foot rest, etc.)

Added March 2013
377.2.13.1.37Sharps38 a. Are sharps containers tamper-resistant and installed only in locations where the containers can be continuously monitored by staff?
38 b. Have plastic items, in areas where suicidal patients have access to or can potentially gain access to, been assessed for their ability to be torn or broken and subsequently created into sharp objects that could be used for self-harm or to harm others.?Inspect ward and patient rooms. Plastic items seem safe to have on mental health units treating actively suicidal patients and other areas treating or holding suicidal patients that are not on 1:1 observation (e.g., psychiatric holding areas in emergency departments); however, some plastics, when broken or torn, create sharp edged pieces that can be used for self harm or harm to others. Updated September 2011See Patient Safety Advisory AD11-02.
38 (repeat of #23 above)13.00-1.00-38.00Corridor Doors23.a. Do corridor doors to patient sleeping rooms have the ability to swing out into the corridor or have a wicket door? (Only New Units)

23. b. If a gasket or sweep is used, it should be cut into sections that are short enough (e.g., 12 inches or less) so that if the gasket or sweep is removed it cannot be used for self harm.

23. c. Do corridor doors to patient sleeping rooms have an over-the-door alarm? Updated November 2019

23. d. Are all over the door alarms checked semi-annually to make sure they are still working properly? Updated November 2019 Because of Life Safety Code limitations regarding door swing into the corridor and corridor obstruction from a fully-opened door, corridor doors have traditionally been designed to swing into the room. For corridor doors in new construction it is recommended to install a door and frame assembly that will permit the door to swing in both directions. Normal operation could be door swing into the room, but if necessary (e.g., patient barricaded inside the room), staff could release the door stop so that the door could swing into the corridor. NOTE: The use of a wicket door (a door within a door) is also acceptable in both new and existing construction. Wicket doors must not form anchor points (Added Sept 2020)

Refer to the Life Safety Code (NFPA 101) for the complete set of door requirements. Note: The 2012 Edition of the Life Safety Code has been changed (See 18.3.6.3.9.2 below) based upon a proposal by the VA to assist in the hardware selection for psyche facilities. It would essentially allow the option of using a roller latch (not previously permitted in new construction) along with no door handle to assist in meeting the Life Safety Code corridor door requirements. Contact: peter.a.larrimer@va.gov if you have questions.

Please Note: We have not been able to find a corridor door that completely eliminates all suicide hazards. Corridor doors must also be designed to limit the transfer of smoke so they cannot be cut down.

A Memo from 10N dated May 10, 2019 required all sleeping room corridor doors to have an over-the-door alarm by January 1, 2020.

38.1 13.00-1.00-38.01 Corridor Doors 38.1 Are all components of the over the door alarms free of anchor points? (Added Sept 2020) Over-the-door alarms must be inspected to ensure that they have been installed properly and do not have anchor points. See Patient Safety Advisory AL 20-02 Anchor point identified on The Door SwitchTM over-the-door alarm product in Veterans Health Administration (VHA) acute mental health units

MHEOCC for Locked Mental Health Units, General Criteria

&"Arial Narrow,Regular"Page &P of &N http://www.patientsafety.gov/alerts/AD11-02.pdfhttp://vaww.ncps.med.va.gov/Guidelines/alerts/Docs/AD12-01.pdfhttp://vaww.ceosh.med.va.gov/01FS/Pages/firesafety.shtmlhttps://vaww.sde.portal.va.gov/sites/fo/svcs/ectm/fis/wireless/Shared%20Documents/Important%20Docs%20for%20Sites/Installation%20Docs/Mental%20Health%20Areas%20Installation%20Guide.pdfhttp://vaww.office.ncps.med.va.gov/tools/pslog/edit.asp?id=937http://www.cooperindustries.com/content/public/en/wiring_devices/products/receptacles/residential/aspire/aspire_tamper_resistant_gfcis_9566tr_9569tr.html?_ga=2.252483850.203627272.1561398478-1792284201.1561398478 Sleeping Rooms

Version 09-30-2020
Mental Health Environment of Care Checklist for Sleeping Rooms
In addition to the following criteria, sleeping rooms must also meet all General Criteria.
Ques. No.ePSAT cross reference numberSite / ItemQuestions / CriteriaRationale / Assessment Methods:MetPartially MetNot MetComments
387.2.13.2.1Mounted FixturesAre all mounted fixtures designed to prevent attachment of devices that could be used to inflict self-harm?
Wireless Access Points for computers should not be installed in patient sleeping rooms or bathrooms.Sprinkler heads; flush mounted vent covers free of louvers; no attachment points on furniture parts or doors (i.e., no hooks) or anything fixed to the walls or ceilings. Tamper-resistant screws should be used on all devices.

Note: break-away clothing rods are not allowed.

No rods of any kind should be allowed.

39 7.2.13.2.1.01 Door Locks Are locks on patient rooms free of anchor points and able to be open by staff? Also see 23 e. under the general criteria. (Added October 2010)

1. There is a requirement that all female patient rooms on mixed gender units have door locks. This is included in VHA Handbook 1160.01, Uniform Mental Health Services in VA Medical Centers and Clinics, as follows:

“All inpatient and residential care facilities must provide separate and secured sleeping accommodations for women. Mixed gender units must ensure safe and secure sleeping and bathroom arrangements, including, but not limited to door locks and proximity to staff” (p. 11).

3. For mental health units treating suicidal patients, it is important not to introduce new anchor points for hanging when adding locks to corridor doors to sleeping rooms. It is also critical to install door locks that can be opened by staff permitting them to enter the room and locking systems that do not prevent the patient from exiting the room (the exiting requirement does not apply to seclusion rooms). Either a manual locking system without anchor points or an electronic locking system that could be operated via a key fob or access card with rounded edges would be acceptable. Such an electronic locking system must also allow for staff access and have an override system that will allow for doors to be unlocked in the event of a power loss or system malfunction. Moreover, it is recommended that door locks not include slots in which cards are to be inserted or keyholes, as other materials may be placed in these slots and cause the locks to malfunction; rather, electronic sensors are recommended for electronic door locking systems, and cipher locks are recommended for mechanical locks. [Note: All locking systems must be in compliance with the requirements of the Life-Safety Code (National Fire Protection Association 101)].

4. In rare cases, the treatment team may determine that it is contraindicated to place a female patient in a sleeping room that has a corridor door that locks. In such instances, the reasons for not placing the patient in a locking room must be documented in the chart.

39.1 Sleeping Room Doors 39.1 a. Do all sleeping room doors have an over the door alarm?

39.1 b. Are all over the door alarms checked semi-annually to make sure they are still working properly? A May 10, 2019 memo from 10N states:

Effective January 1, 2020, all VA medical facilities with an acute mental health unit will be required to install door top alarms as recommended by the CFM design guide

Updated November, 2019
407.2.13.2.2MirrorsAre patient room mirrors shatter-resistant and not able to be used as an anchor point?Mirrors should be stainless steel, not glass and have no anchor points for hanging.
417.2.13.2.3Platform BedsAre all beds free of anchor points for hanging?Platform beds are the safest for an acute psychiatric environment.When reviewing beds make sure it is not possible to create an anchor point by standing the bed on its end or side, or by looping a lanyard over the top or back of the bed to hang. With some beds it is necessary to bolt them to the floor to avoid them being used as an anchor point. Securing platform beds to the floor also eliminates the beds being moved and used to barricade the door or stacked one on top of another to reach the ceiling. (added October 2010).
41.17.2.13.2.3.01Medical BedsHave electric and manually adjustable beds been eliminated unless indicated by clinical need?If electric beds are necessary, power cords should be shortened and securely fastened. If hospital beds (electrical or mechanical) are used in locked units, they should be in a sleeping room that is close to the nursing station, patients should be watched when the beds are occupied (often there is other medical equipment in the room, since the medical condition is driving the need for the hospital bed) and the room should be locked when not occupied.When patients are in a hospital bed, or have medical equipment, a risk assessment should be conducted frequently to determine potential level of suicide risk. (section on medical beds added January 2013

41.2 7.2.13.2.3.02 Pillows and mattresses Are pillows and mattresses free of plastic, vinyl, or other materials that could be removed and used for suffocation or strangulation? Pillows and mattresses should not have covers that can be easily removed by the patient and used for suffocation. This requirement is consistent with eliminating plastic trash can liners (refer to question #35) and vinyl or plastic shower curtains (refer to question #59). Updated 2014

See Use of elastic-hemmed fitted bed sheets in mental health units AL 11-02 http://vaww.ncps.med.va.gov/Guidelines/alerts/Docs/AL11-02Elastic-hemmedFittedBedSheets.pdf

41.3 7.2.13.2.3.03 Sheets Are all fitted bed sheets (with elastic) removed from the units and replaced with either non-elastic fitted sheets or standard flat bed sheets? While bed sheets themselves can be used as ligatures, bed sheets with elastic are potentially more dangerous as ligatures than bed sheets without elastic. Elastic wrapped tightly around a neck may continue to remain tight and strangle the patient, even after the patient has passed out and stopped applying tension.

NOTE: This is specific to fitted sheets and is not intended to suggest that other items which generally do not have non-elastic alternatives (e.g. pajama pants, underwear, brassieres) be removed from the units.