- K041--Transformer Cooling Fans Installation in Building 31 VA Medical Center White River Junction, VT
- Solicitation number
- 36C24121Q0457
View the file
Other files
| File | Type | Posted |
|---|---|---|
| T17 Transformer.jpg | JPG image | |
| Transformer Front Work Area.jpg | JPG image | |
| Transformer Rear Work Area.jpg | JPG image | |
| T18 Transformer.jpg | JPG image | |
| P07 Wage Determination 36C241-21-AP-1609.pdf | ||
| SOW Install Cooling Fans in Building 31 03 03 21.docx | DOCX document | |
| 36C24121Q0457_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.
is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer) 36C241 405-17-021 Department of Veterans Affairs Network Contracting Office 1 Contracting Officer 623 Atwells Avenue Providence
RI
02909
To all Offerors/Bidders
36C24121Q0457 07-01-2021
X X X
The solicitation identified in block 9A above for Building 31 Transfrmer Cooling Fam Installation at the VA White River Junction is hereby amendment to provide the RFI questions and responses. See page 2.
The due date for receipt of quotes is not extended and remains close of business on 07/23/2021.
Page 2 – Amendment A0001 to 36C24121Q0457 Project - Bldg 31 Transformer Cooling Fans Installation at VA White River Junction
The following Requests for Information with the responses are provided:
Q. Can you provide nameplates and drawings for each transformer?
A. Photos of the name plates are attached. There are two attachments and they are titled T18 Transformer and T17 Transformer.
Q. Can you provide nameplates and/or specifications for the existing parts that are being replaced so we can source equivalent? Or do you have specifications of alternate new equipment that you specifically want?
A. From the SOW: Six (6) 120VAC cooling fans
· Mounting brackets
· Two (2) digital transformer temperature monitors and controllers
· Two (2) control power transformers
· SIS wiring
· Six (6) insulated thermocouples
· Misc. items
Q. Can you provide oil quality and DGA oil diagnostics for each transformer?
A. Since the transformers are dry types, there is no oil used in the transformers.
Q. Can you provide photos of each transformer and/or map showing access around the transformer to perform the work?
A. Photos are attached. There are two attachments and they are titled Transformer Front Work Area and Transformer Rear Work Area.
Q. Is there any electrical testing required on the transformers? Or strictly functional checks of replaced parts?
A. The SOW does call for testing of the new cooling system at completion of the install.
Q. Please provide GE Fan model number for the Transformer Fans.
A. Currently no fan is in place.
Q. Are the 750KVA pad mounted transformers or dry types.
A. According to the SOW, the transformers are dry types.
Q. The “Statement of Work” 1.A: Indicates six (6) fans + the other equipment. Each Transformer will require Six (6) to Twelve (12) fans, or 12 to 24 Total Fans will be required for the 2 Transformers.
A. The main goal of the cooling fans is to increase the capacity of the transformers from 750 KVA to 1000 KVA. Past engineering investigations have pointed us towards 12 fans per transformer, for a total of 24 fans.
See attached document: T17 Transformer.
See attached document: T18 Transformer.
See attached document: Transformer Front Work Area.
See attached document: Transformer Rear Work Area.