36C24118Q0130-003.xlsx

XLSX spreadsheet 15 KB Posted

Attached to
SB SA FireDoor Assembly Repair
Solicitation number
36C24118Q0130
Issued by

About this file

36C24118Q0130 Attachment A - Known Door Deficiencies.xlsx

View the file

Other files

File Type Posted
36C24118Q0130-000.docx DOCX document
36C24118Q0130-001.docx DOCX document
36C24118Q0130-002.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Deficiency decsription

Door ID #BuildingFloorRoom #Location Desc.Deficiencies
B-FD-0011BW55Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
B-FD-0031BW54Electrical ClosetO2-Door does not close completely (operational)
B-FD-0041BE05Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
B-FD-0071BN98Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
B-FD-0101BN95Mechanical roomH5- Missing or incorrect screws (hinges), C3- Non-approved hold-open device (door closer)
B-FD-0151BN81Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
1-FD-00811SW102Electrical ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
1-FD-00911SW103Electrical ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
1-FD-01011W107Sprinkler ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
1-FD-01411E109Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
1-FD-01811N144Storage RoomO2-Door does not close completely (operational)
1-FD-02011N147ADouble Doors leading into Bldg 15F2-Fire label painted over(frame), D11-Unused fastener holes(door)
1-FD-02111N147ADouble Doors leading into Bldg 15F2-Fire label painted over(frame), D11-Unused fastener holes(door)
2-FD-00112N264Fire Closet N264F1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
2-FD-00612E208Fire Closet E208F10- Unused fastener holes(frame), D1-Missing fire label(door)
2-FD-00712E209Stairwell #1F9-Missing silencers(frame), F10-Unused fastener holes(frame)
2-FD-01112W248Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
2-FD-01312W247Electrical ClosetO2-Door does not close completely (operational)
3-FD-00113N388Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
3-FD-00413N377Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
3-FD-00713E314Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
3-FD-00813E316Stairwell #1D11- Unused fastener holes(door)
3-FD-00913E315Electrical ClosetO2-Door does not close completely (operational)
3-FD-01213W351Fire closetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
3-FD-01413W350Electrical ClosetO2-Door does not close completely (operational)
4-FD-00114N496Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
4-FD-00414N480AElectrical ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door), O2-Door does not close completely(operational)
4-FD-00514N481Stairwell #4F2- Fire label painted over(frame)
4-FD-00614E413Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
4-FD-00714E415Stairwell #1F9- Missing Silencers (Frame)
5-FD-00115W550Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door), C1-Missing or Defective door closer
5-FD-00315W549Electrical ClosetO2-Door does not close completely (operational)
5-FD-00415W556Electrical ClosetF2-Fire label painted over(frame), D2-Fire label
5-FD-00515W556Electrical ClosetF2-Fire label painted over(frame), D2-Fire label
5-FD-00615N578Stairwell #2F1-Missing fire label(frame), D1-Missing fire label(door), D14-Vison light not labeled(door)
5-FD-01115N566Mechanical roomF1-Misiing fire label(frame), D2-Fire label painted over(door)
5-FD-01315E513Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door)
6-FD-00216N662Stairwell #2L8- Missing or incorrect screws(Locks)
6-FD-00516E613Electrical ClosetF9- Missing Silencers (Frame)
6-FD-00616E612Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door), C1-Missing or Defective door closer
6-FD-00716N660Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door), C1-Missing or Defective door closer
6-FD-00816W645Electrical ClosetF2-Fire label painted over(frame), C1-Nissing or defective door closer(door closer)
6-FD-00916W645Electrical ClosetF2-Fire label painted over(frame), C1-Nissing or defective door closer(door closer)
6-FD-01016W640Fire ClosetF1-Missing Fire Label(frame), D1-Missing Fire Label (Door), C1-Missing or Defective door closer
6-FD-01216W639Electrical ClosetF9- Missing Silencers (Frame)
B-FD-00215BD02Electrical ClosetF9- Missing Silencers (Frame)
B-FD-00315BD02Electrical ClosetF9-Missing Silencers(frame), H5-Missing or incorrect screws(hinges)
B-FD-00415BD04AIT ClosetF1-Missing Fire label(frame), F9-Missing silencers(frame), H5- Missing or incorrect screws(hinges)
1-FD-004151D104AIT ClosetF2-Fire label painted over(frame), D1-Mising fire label(door)
2-FD-002152S2AStairwell #2F2-Fire label painted over(frame), M4- Incorrect clearance between door and frame head(Misc), M5- Incorrect clearance bewteen door and floor(misc)
2-FD-003152C201Double Entrance doors from Bldg 1F2-Fire label painted over, D14-Vision light not labeled(door), M5-Incorrect clearance between door an dfloor(misc)
2-FD-004152C201Double Entrance doors from Bldg 1F2-Fire label painted over(frame), D14-Vision light not labeled(door)

# of Deficiencies

Deficieny descriptionNumber of deficiencies
Frame
F1-Missing fire label25
F2-Fire label painted over11
F9-Missing Silencers7
F10-Unused fastener holes1
Door
D1- Missing fire label25
D2-Fire label painted over3
D11-Unused fastener holes3
D14- Vision light not labeled3
Hinges
H5-Missing or incorrect screws3
Locks
L8-Missing or incorrect screws1
Door Closers
C1- Missing or defective closer6
C3-Non-Approved hold-open device1
Miscellaneous
M4-Incorrect clearance between door and frame head1
M5-Incorrect clearnace between door and floor2
Operational
O2- Door does not clmpletely7