36C10X26R0062.pdf

PDF 333 KB Posted

Attached to
NX EQ Monitors_Physio_Neurology_Intraop_EEG (VA-26-00045643)
Solicitation number
36C10X26R0062
Issued by

About this file

This is a Combined Synopsis/Solicitation Notice for Electroencephalography (EEG) systems issued by the Department of Veterans Affairs, Enterprise Procurement Office-Frederick. The solicitation number is 36C10X26R0062, with a response deadline of October 7, 2026, at 12:00 PM ET. This is a total service-disabled veteran-owned small business (SDVOSBC) set-aside for a single-award Requirements contract with firm-fixed-price (FFP) delivery orders under FAR Subpart 16.5. The contract will cover one 12-month base year with four 12-month option years, with nationwide delivery on an FOB destination basis.

The requirement is for Natus® brand name or equal EEG systems and accessories comprising 104 contract line items (CLINs 0001–0104) that support routine EEG assessments, intraoperative neurophysiological monitoring, long-term monitoring, polysomnography, and ambulatory EEG capabilities for use across VA medical centers and facilities. Offerors must meet 14 salient characteristics (SCs) including routine and ambulatory EEG capability, sleep study functionality, analysis software, seizure/spike detection, simultaneous video and audio recording, remote viewing, continuous long-term recording with infrared capability, minimum 32 channels, IEC 60601-2 electromagnetic emissions compliance, extended service and support options, one-year minimum warranty, training provision, and FDA/501(k) approval. Only new equipment is acceptable; distributors must be authorized resellers with OEM letters dated within 12 months of solicitation close and valid for the contract life. Vendors must complete a supplied salient characteristics chart identifying where compliance is demonstrated in their technical submission. Questions are due by September 23, 2026, at 12:00 PM ET to the Contract Specialist (Levi.Russin@va.gov) and Contracting Officer (Jessica.Smith32@va.gov).

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Combined Synopsis/Solicitation Notice

*= Required Field Combined Synopsis/Solicitation Notice

SUBJECT* NX EQ EEG Monitors

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE* 21703

SOLICITATION NUMBER* 36C10X26R0062

RESPONSE DATE/TIME/ZONE 10-07-2026 12:00 EASTERN TIME, NEW YORK, USA

ARCHIVE 60 DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS N

SET-ASIDE SDVOSBC

PRODUCT SERVICE CODE* 6515

NAICS CODE* 334510

CONTRACTING OFFICE ADDRESS Enterprise Procurement Office-Frederick

Department of Veterans Affairs

5202 Presidents Court, Suite 103 Frederick MD 21703

POINT OF CONTACT*

CONTRACT SPECIALIST

Levi Russin Levi.Russin@va.gov

CONTRACTING OFFICER

Jessica Smith Jessica.Smith32@va.gov

PLACE OF PERFORMANCE

ADDRESS Nationwide

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL https://www.va.gov/opal/sac/index.asp

URL DESCRIPTION VA | OALC | OPAL | SAC

AGENCY CONTACT’S EMAIL ADDRESS Levi.Russin@va.gov EMAIL DESCRIPTION CONTRACT SPECIALIST, Levi Russin

DESCRIPTION

Solicitation Number:

36C10X26R0062

Notice Type:

Combined Synopsis/Solicitation

Synopsis:

COMBINED SYNOPSIS/SOLICITATION

This is a combined synopsis/solicitation for commercial items prepared in accordance with (IAW) the format in Federal Acquisition Regulation (FAR) 12.2, “Solicitation, Evaluation, and Award,” as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; offers are being requested, and a written solicitation will not be issued.

Solicitation number 36C10X26R0062 is issued for this combined synopsis/solicitation; this solicitation is being issued as a Request for Proposal (RFP). This combined synopsis/solicitation is issued under the agency's implementation of the Federal Acquisition Regulation (FAR) Overhaul, as adopted through agency class deviation. All applicable provisions, clauses, definitions, and procedures are those contained in the Overhaul text and the agency's implementation deviations. In the event of a conflict with the codified FAR, the adopted Overhaul text governs. The full text of provisions and clauses may be accessed electronically at https://www.acquisition.gov/far-overhaul.

Requirement Description:

The Veterans Health Administration (VHA) Equipment Life Cycle Management (ELCM) Program has identified the Electroencephalography (EEG): Electroencephalographic Systems as a candidate for the Department of Veterans Affairs VA-wide (otherwise referred to as “national”) Non-Expendable Equipment (NX EQ) contract award.

A single award Requirements contract will be awarded IAW all terms, conditions, provisions, specifications, and schedule of this solicitation herein. Offers shall contain the terms for cost/price and technical capabilities of brand name or equal equipment. The Government reserves the right to award without discussions.

The associated North American Industrial Classification System (NAICS) code for this procurement is 334510 – Electromedical and Electrotherapeutic Apparatus Manufacturing, Product Service Code: 6515 – Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 1,250 employees. There is an existing Non- Manufacturer Rule Class Waiver for Electromedical and Electrotherapeutic Apparatus Manufacturing under NAICS 334510 as of December 20, 2007.

https://www.acquisition.gov/far-overhaul

This procurement action is issued as a total service-disabled veteran-owned small business set-aside.

This acquisition is for a single award Requirements contract with firm-fixed priced (FFP) delivery orders IAW FAR Subpart 16.5 for Natus® brand name or equal NX EQ Electroencephalography (EEG): Electroencephalographic Systems and accessories as identified in ATTACHMENT A – PRICE COST SCHEDULE - NX EQ EEG SYSTEMS. Offerors shall provide a quote for all Contract Line-Item Numbers (CLINs) listed in ATTACHMENT A –

PRICE COST SCHEDULE - NX EQ EEG SYSTEMS.

The ordering period is for one 12-month base year with four 12-month option years. Delivery is Free on Board (FOB) destination. FFP Orders will be placed against this contract in writing and will provide the delivery locations, delivery dates and exact quantities.

The FAR provision at 52.212-1, Instructions to Offerors-Commercial Products And Commercial Services, applies to this acquisition including attached addenda to the provision (see

ATTACHMENT D - SOLICITATION PROVISIONS - NX EQ EEG SYSTEMS).

The FAR provision at 52.212-2, Evaluation-Commercial Products and Commercial Services, and the specific evaluation criteria as attached addenda also applies to this acquisition (see

ATTACHMENT D - NX EQ EEG SYSTEMS).

Clause at 52.212-4, Contract Terms and Conditions-Commercial Products and Commercial Services, applies to this acquisition and a statement regarding any addenda to the clause. (see

ATTACHMENT C - CONTRACT CLAUSES – NX EQ EEG SYSTEMS).

All interested Offerors must be registered in the System for Award Management (SAM) prior to submitting a proposal. You may access SAM at https://sam.gov/SAM/.

Questions regarding this combined synopsis/solicitation are due via email by 12:00 PM ET on September 23, 2026, to Contract Specialist, Levi.Russin@va.gov, and Contracting Officer, Jessica Smith at Jessica.Smith32@va.gov. No questions will be accepted after the due date. No calls will be accepted.

Offers are due via email by 12:00 PM ET on October 7, 2026, to Contract Specialist, Levi.Russin@va.gov, and Contracting Officer, Jessica Smith at Jessica.Smith32@va.gov.

PRODUCT DESCRIPTION

1. SCOPE OF WORK

The VHA Non-Expendable Equipment National Program has identified the Electroencephalography (EEG): Electroencephalographic Systems product line as a candidate for a VA-wide (otherwise referred to as “national”) single award Requirements contract.

https://sam.gov/SAM/ mailto:Courtney.Chattman@va.gov mailto:Jessica.Smith32@va.gov mailto:Courtney.Chattman@va.gov mailto:Jessica.Smith32@va.gov

EEG uses electrodes placed on a patient's scalp to measure, amplify, filter, and record the electrical signals (EEG signals) generated by the brain and subsequently display the acquired patient data in digital wave forms. There are three Neurodiagnostic procedures that Electroencephalographic systems are used for: EEG, Intraoperative Neurophysiological Monitoring (IONM), Long-Term Monitoring (LTM). The first Neurodiagnostic procedure, EEG, is used in areas such as Outpatient Labs, Inpatient Wards, and ICU settings. It observes and diagnoses a range of neurologic conditions, including epilepsy. It can also be employed to evaluate psychiatric disorders and differentiate them from neurologic conditions. IONM has the capability to monitor the functional integrity of neural structures during surgeries such as Carotid Endarterectomy, Corticography, Brain Mapping, Stimulation, Aneurysm Clipping, and the effects of anesthesia on the brain during these procedures. LTM is the collection of EEG data over a period of time. These recordings include Ambulatory EEG (aEEG), which is used for recording at the Veteran’s residence. Continuous EEG (cEEG) is used for inpatient video monitoring greater than 2 hours. Prolonged EEG (pEEG) monitoring is used for outpatient video monitoring greater than 2 hours. Video EEG (vEEG) is an elective EEG admission for prolonged video EEG recording which is performed in an Epilepsy Monitoring Unit (EMU). An EMU is a specialized inpatient unit designed to evaluate, diagnose, and treat seizures. The ability to record and monitor non-invasive scalp electrode EEG, intracranial EEG (Grid and Strip), and invasive stereotactic depth electrodes (sEEG) is the gold standard using state-of-the art continuous video electroencephalogram (vEEG) monitoring technology.

Offerors must demonstrate the ability to meet all requirements for the solicitation. The objective is to provide Electroencephalography (EEG): Electroencephalographic Systems to be used by clinicians throughout the VA medical centers and facilities. The period of performance is for a base of 12-months with four 12-month option periods.

2. REQUIREMENT

This requirement will be solicited and awarded as “Brand Name or Equal” which requires the offeror indicate that each product being offered as an “equal” product to the Natus® Inc EEG system. For each equal product, the offeror must include a description reflecting the salient characteristics (SC) and level of quality that will satisfy the salient physical, functional, or performance characteristics of the equal product(s) specified in the solicitation. The offeror must also clearly identify the item by brand name (if any) and make/model number. Finally, the offeror must include descriptive literature, such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the Contracting Officer, clearly describe any modifications it plans to make to a product to make it conform to the solicitation requirements.

The following line-items comprise the Natus® Inc EEG and accessories product line:

Contract Line Items Manufacture Part Number Description

0001 NATUS INC LC101-10 NeuroWorks 10.x Acquisition Software with Spike / Event and High Res Video

0002 NATUS INC LC100-10 NeuroWorks 10.x Acquisition Software without Spike / Event

0003 NATUS INC LC306-10 NeuroWorks/SleepWorks 10.x Citrix Software

0004 NATUS INC LC500-10 NeuroWorks/SleepWorks 10.x Data Server Software

0005 NATUS INC 105075XL 24in FP Monitor 0006 NATUS INC 16269 Bulk connector pin box assembly 1 0007 NATUS INC ENCRYPTED Computer Provided with Encrypted

Hard Drive 0008 NATUS INC PK1057U EEG Laptop Upg w Startech Grb 0009 NATUS INC PK1204HD EEG/Sleep Acq Desktop with IP

PTZ 1080p HD Color/BW Camera on ErgoJust Cart

0010 NATUS INC PK1065 EEG/Sleep Video Acquistion Laptop with Compact IP Camera

0011 NATUS INC 12760 Embletta MPR PG with ST Proxy

XR ENU

0012 NATUS INC 10368 EMU40 / Brain Monitor Wall Mount Kit

0013 NATUS INC PK1072-NTB-9 EMU40EX with new Natus Base (Requires NW 9.x or newer)

0014 NATUS INC 28066 EMU40EXQ Breakout Box 0015 NATUS INC ISO-NA Isolation Transformer - 110V 0016 NATUS INC ISO-NA-EJ Isolation Transformer - 110V

ErgoJust cart 0017 NATUS INC 12269 LCD 30-inch monitor with soundbar 0018 NATUS INC PK1103 LED Photic Stimulator with Stand 0019 NATUS INC PK1102 LED Photic Stimulator.

0020 NATUS INC UPS-NA-EJ Medical Grade UPS with Isolation -

110V ErgoJust Cart 0021 NATUS INC REPORT-EDITOR MS Word Report Editor for

Neuroworks/Sleepworks 0022 NATUS INC 16862 Natus Base Unit 0023 NATUS INC PK1274 Natus Brain Monitor Amplifier 0024 NATUS INC 21911 Natus Brain Monitor Breakout 0025 NATUS INC PK1174 Natus Quantum (Phase II) Amplifier

- 256 Channels 0026 NATUS INC PK1014 Review/Monitoring Desktop

(NeuroWorks software not included) 0027 NATUS INC LC101-U10 Upgrade NeuroWorks 10.x

Acquisition Software with Spike / Event and High Res Video

0028 NATUS INC PK1092T-FHD 1080p HD IP PTZ Camera Ceiling mounted

0029 NATUS INC PK1093P-FHD 1080p HD IP PTZ Camera Wall mounted

0030 NATUS INC AMB-MON-2VIDWIFI-

10-NOAMP

Ambulatory Monitoring Package with Tablet, NW 10, Dual IP Wi-Fi Camera, NO AMP, 110V

0031 NATUS INC AMB-MON-VIDWIFI-

10-NOAMP

Ambulatory Monitoring Package with Tablet, NW 10, Single IP Wi-Fi Camera, NO AMP, 110V

0032 NATUS INC AMB-MON-2VIDWIFI-

Ambulatory Monitoring Package with Tablet, Software NW 10, Dual IP Wi-Fi Camera Kit - 110V

0033 NATUS INC AMB-MON-VIDWIFI-

Ambulatory Monitoring Package with Tablet, Software NW 10, Single IP Wi-Fi Camera Kit - 11

0034 NATUS INC PK1001U EEG Desktop Upg w Startech Grb 0035 NATUS INC PK1108T-FHD EEG/Sleep Tech Room Acquisition

Desktop with Ceiling Mount 1080p HD IP PTZ Camera

0036 NATUS INC 12759 Embletta MPR PG with ST Proxy

XS ENU

0037 NATUS INC W6437H EMU40EX / Brain Monitor Breakout Cable 15ft

0038 NATUS INC W6438H EMU40EX / Brain Monitor Breakout Cable 30ft

0039 NATUS INC 021743-9 EMU40EX Breakout Box Add-on kit for Natus Base 2nd gen.

0040 NATUS INC 10193 Extended Video Monitoring Controllers

0041 NATUS INC HL7-OUT-10 HL7 Implementation for NeuroWorks 10.x - EXPORT

0042 NATUS INC HL7-IN-10 HL7 Implementation for NeuroWorks 10.x - IMPORT

0043 NATUS INC HL7-MM-10 HL7 Implementation for NeuroWorks 10.x for Existing HL7

EMG - IMPORT/EXPORT

0044 NATUS INC HL7-IN-U10 HL7 Implementation for NeuroWorks 10.x UPGRADE -

IMPORT/EXPORT

0045 NATUS INC 48354 Logitech Wireless Keyboard and mouse for Trex HDM Case (English)

0046 NATUS INC UPS-NA Medical Grade UPS with Isolation (North America 5-15R HG plug)

0047 NATUS INC 021911-9 Natus Brain Monitor breakout Add-on kit for Natus Base 2nd gen.

0048 NATUS INC BM-CH-10 Natus Brain Monitor IP Vid Cart System (incl BM, NW10, ErgoJust Lite, 24in Mtr, Photic)

0049 NATUS INC 24318 Natus Brain Monitor Wall Mount Kit 0050 NATUS INC PK1245 Natus Embla SDx Amplifier 0051 NATUS INC 21920 Natus Embla SDx Breakout 0052 NATUS INC 021920-9 Natus Embla SDx breakout Add-on kit for Natus Base 2nd gen.

0053 NATUS INC 021676-9 Natus Quantum 2nd gen. 256ch breakout Add-on kit for Natus base 2nd gen.

0054 NATUS INC LC105-10 NeuroWorks 10.x Nurse Station Software

0055 NATUS INC LC103-10-UNL NeuroWorks 10.x Review Non- XLTEK PC (Single-site unlimited)

0056 NATUS INC LC102-10 NeuroWorks 10.x Review Software 0057 NATUS INC LC103-10 NeuroWorks 10.x Review Software

Non-XLTEK PC 0058 NATUS INC LC301-10 NeuroWorks/SleepWorks 10.x

Acquisition Software with Spike / Event and High Res Video

0059 NATUS INC LC300-10 NeuroWorks/SleepWorks 10.x Acquisition Software without Spike / Event

0060 NATUS INC LC306-10-ADD3 NeuroWorks/SleepWorks 10.x Citrix Software - Add 3 Users to an existing User license

0061 NATUS INC LC302-10 NeuroWorks/SleepWorks 10.x Review Software

0062 NATUS INC PK1204HD-NPC PK1204HD

0063 NATUS INC 4244014 Prem Intercom Sys W/Recording 0064 NATUS INC 10441 Rollstand for LED photic 0065 NATUS INC LC202-10 SleepWorks 10.x Review Software 0066 NATUS INC LC203-10 SleepWorks 10.x Review Software

Non-XLTEK PC 0067 NATUS INC LC203-10-5 SleepWorks 10.x Review Software

Non-XLTEK PC 5pk

0068 NATUS INC PSG-CEIL-PTZHD-

SDX-10

SleepWorks Sys with Ceiling Mounted 1080p PTZ Video,SDx amp, SleepWorks 10, no Sensor Kit

0069 NATUS INC PSG-WALL-PTZHD-

SDX-10

SleepWorks Sys with Wall Mounted 1080p PTZ Video, SDx amp, SleepWorks 10, no Sensor Kit

0070 NATUS INC PSG-CEIL-PTZ-FHD-

NDX-10

SleepWorks sys. Ceiling mount 1080p PTZ, Embla NDx, PC, 24" LCD, SleepWorks V10.x, Rpt Ed

0071 NATUS INC PSG-WALL-PTZ-

FHD-NDX-10

SleepWorks sys. Wall mount 1080p PTZ, Embla NDx, PC, 24" LCD, SleepWorks V10.x, Rpt Ed.

0072 NATUS INC PK1058 Small-form Factor Computer (NeuroWorks/SleepWorks not Included)

0073 NATUS INC 15968 StarTech PCIe Gigabit NIC 0074 NATUS INC EZ-CASEUPG-2 Trex HDM EZ-CASE Replacement for Dual IP Cameras - NA camera power supply

0075 NATUS INC EZ-CASEUPG-1 Trex HDM EZ-CASE Replacement for Single IP Camera - NA camera power supply

0076 NATUS INC AMB-MON-10 Trex HDM System with Tablet, Software NW 10, Pouch - 110V

0077 NATUS INC AMB-MON-10-

NOCASE

Trex HDM System, Software NW 10, Pouch - 110V

0078 NATUS INC LC105-U10 Upgrade NeuroWorks 10.x Nurse Station Software

0079 NATUS INC LC105-U10 Upgrade NeuroWorks 10.x Review Software

0080 NATUS INC LC103-U10 Upgrade NeuroWorks 10.x Review Software Non-XLTEK PC

0081 NATUS INC LC105-U9 Upgrade NeuroWorks 9.x Nurse Station Software

0082 NATUS INC LC103-U9 Upgrade NeuroWorks 9.x Review Software Non-Natus PC

0083 NATUS INC LC301-U10 Upgrade NeuroWorks/SleepWorks 10.x Acquisition Software with Spike / Event and High Res Vi

0084 NATUS INC LC306-U10 Upgrade NeuroWorks/SleepWorks 10.x Citrix Software

0085 NATUS INC LC500-U10 Upgrade NeuroWorks/SleepWorks 10.x Data Server Software

0086 NATUS INC LC305-U10 Upgrade NeuroWorks/SleepWorks 10.x Nurse Station Software

0087 NATUS INC LC302-U10 Upgrade NeuroWorks/SleepWorks 10.x Review Software

0088 NATUS INC LC303-U10 Upgrade NeuroWorks/SleepWorks 10.x Review Software Non-XLTEK

PC

0089 NATUS INC LC200-U10 Upgrade SleepWorks 10.x Acquisition Software without Spike / Event

0090 NATUS INC LC202-U10 Upgrade SleepWorks 10.x Review Software

0091 NATUS INC LC203-U10 Upgrade SleepWorks 10.x Review Software Non-XLTEK PC

0092 NATUS INC 24252 Sleep Supplies Starter Kit with Single Use Supplies for Embla DX Series Amplifiers

0093 NATUS INC SVC800INSTALl_INC IT DEMO ACQ KIT WITH NATUS BRAIN MONITOR NW10.x

0094 NATUS INC SVC800TRAIN_INC IT DEMO ACQ KIT WITH EMU40EX

NW10.x

0095 NATUS INC IT-BM-ACQ-10

IT DEMO SERVER KIT NW10.x

0096 NATUS INC IT-EMU40-ACQ-10 Persyst AMBI - Routine and Ambulatory Review

0097 NATUS INC IT-SERVER-DEMO-

KIT-10 Persyst CPRA - Clinical Review 5+

0098 NATUS INC 2928

Persyst CPRI - Clinical Review

0099 NATUS INC 002941-INC Persyst CPAA - Continuous / Long- Term Acquisition 5+

0100 NATUS INC 2930

Persyst AERI - Advanced Review

0101 NATUS INC 002944-INC Persyst CPAI - Continuous / Long- Term Acquisition

0102 NATUS INC 10199 Persyst CPRC - Clinical Review for Server

0103 NATUS INC 2929 Installation Included

0104 NATUS INC 3053 Training Included

The VA is seeking offerors who can provide Natus® Inc EEG systems and accessories or equal as listed above which meet all SCs listed below. Offerors may propose any product solution or configuration so long as they meet the SCs.

Offerors may propose an alternative CLIN structure IAW FAR 4.202-2 and 4.202-3. Products proposed in the technical volume must appear on and correspond with the Offeror’s pricing volume (ATTACHMENT A - PRICE COST SCHEDULE - NX EQ EEG SYSTEMS).

Offerors may propose any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these ancillary items must be quantified in the Offeror’s pricing volume with an estimated quantity of zero (0).

Only new equipment is acceptable; no remanufactured or "gray market" items. No product in development shall be considered. All items must be covered by the manufacturer's warranty.

Distributors must be authorized-distributors/resellers as certified by the Original Equipment Manufacturer (OEM) (i.e., OEM letter dated within 12 months of the solicitation close date and duly signed by OEM’s authorized representative) to be eligible for award. The OEM letter must be valid for the life of the contract.

Vendors are required to complete the highlighted area on the SCs Chart located on the Combined Synopsis/Solicitation document listing the location where compliance to the SCs can be found. The chart must be included with the vendor’s submission. Offers which do not include this complete chart will not be considered for award.

CLIN's 0001 to 0103 apply to SC's 1-13 CLIN 0104 applies to SC 14

SC # SALIENT CHARACTERISTICS METHOD OF

EVALUATION SC – Literature Map

SC 1 Must have the capability to perform EEG (Routine) assessments by acquiring and recording data.

Literature Review Brand

Name:

Page #:

SC 2 EEG system must have a fully wireless in-home care (Ambulatory) configuration option

Literature Review Brand

SC 3 Must have the polysomnography (PSG) package option to perform a full sleep study

Literature Review

Brand

SC4 Must have EEG analysis software Literature Review

Brand

SC 5 Must have Seizure and Spike/Burst Detection

Literature Review

Brand

SC 6 Must be able to simultaneously collect video and audio data during EEG data collection

Literature Review

Brand

SC 7 Must have Remote viewing capabilities

Literature Review

Brand

SC 8 EEG must have continuous audio and video (with infrared) data recording capability for assessments greater than two hours (Long Term)

Literature Review Brand

SC 9 Must have a minimum of 32 channels

Literature Review

Brand

SC 10 Must be Electromagnetic Emissions IEC 60601-2 compliant

Literature Review

Brand

SC 11 Must provide extended service and support plan option.

Literature Review

Brand

SC 12 Must have minimum one-year Warranty

Literature Review

Brand

SC 13 Must provide training. Literature

Brand

SC 14 FDA or 501(K) approved

Literature

Brand

• ATTACHMENT A - PRICE COST SCHEDULE - NX EQ EEG SYSTEMS

• ATTACHMENT B - CONTRACT ADMINISTRATION - NX EQ EEG SYSTEMS

• ATTACHMENT C - CONTRACT CLAUSES - NX EQ EEG SYSTEMS

• ATTACHMENT D - SOLICITATION PROVISIONS - NX EQ EEG SYSTEMS

• ATTACHMENT E - QUARTERLY SALES REPORT - NX EQ EEG SYSTEMS

• ATTACHMENT F - PAST PERFORMANCE REFERENCES - NX EQ EEG SYSTEMS

• ATTACHMENT G - PAST PERFORMANCE QUESTIONAIRE - NX EQ EEG SYSTEMS

• ATTACHMENT H - RFQ QUESTIONS - NX EQ EEG SYSTEMS

• ATTACHMENT J - CERTIFICATION OF RECALL OR SAFETY ISSUES - NX EQ EEG

SYSTEMS

• APPENDIX C - NX EQ EEG SYSTEMS

See attached document: ATTACHMENT A - PRICE COST SCHEDULE - NX EQ EEG

SYSTEMS.

See attached document: ATTACHMENT B - CONTRACT ADMINISTRATION - NX EQ EEG

SYSTEMS.

See attached document: ATTACHMENT C - CONTRACT CLAUSES - NX EQ EEG

SYSTEMS.

See attached document: ATTACHMENT D - SOLICITATION PROVISIONS - NX EQ EEG

SYSTEMS.

See attached document: ATTACHMENT E - QUARTERLY SALES REPORT - NX EQ EEG

SYSTEMS.

See attached document: ATTACHMENT F - PAST PERFORMANCE REFERENCES - NX

EQ EEG SYSTEMS.

See attached document: ATTACHMENT G - PAST PERFORMANCE QUESTIONAIRE - NX

EQ EEG SYSTEMS.

See attached document: ATTACHMENT H - RFQ QUESTIONS - NX EQ EEG SYSTEMS.

See attached document: ATTACHMENT J - CERTIFICATION OF RECALL OR SAFETY

ISSUES - NX EQ EEG SYSTEMS.

See attached document: APPENDIX C - NX EQ EEG SYSTEMS.

See attached document: 852.219-76 VA NOTICE OF LIMITATIONS ON

SUBCONTRACTING-CERTIFICATE OF COMPLIANCE FOR SUPPLIES AND PRODUCTS

-DEVIATION.

File details come from the government source that posted it. Updated .