This is a Combined Synopsis/Solicitation Notice and Request for Proposal (RFP) issued by the Department of Veterans Affairs Strategic Acquisition Center in Frederick, Maryland for the procurement of Medtronic EndoFLIP 300 Physiologic Motility Analyzers and related accessories. The solicitation number is 36C10X26R0054, with proposals due by 10:00 AM Eastern Time on October 6, 2026. This is a brand name only, single award Requirements contract for commercial items with a 12-month base period and four 12-month option years, with FOB destination and firm-fixed pricing terms. The requirement encompasses 15 contract line items including the EndoFLIP 300 System (part 47229), existing customer promotion pricing (part 47230), one and two-day on-site training services, reader units, pre-use tubes, endoscopic catheters in various sizes, and one to three-year service plans. Questions must be submitted by September 29, 2026, to Contract Specialist Jalima Jones and Contracting Officer Anthony Zibolski. The procurement is unrestricted full and open competition, classified under NAICS code 339113 (Surgical Appliance and Supplies Manufacturing) and Product Service Code 6515 (Medical and Surgical Instruments, Equipment, and Supplies), with nationwide place of performance across VA Medical Centers. All offerors must be registered in the System for Award Management (SAM) prior to submission.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice
| SUBJECT* |
| NX EQ Physiologic Motility Analyzers (EndoFLIP) |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 21703 |
| SOLICITATION NUMBER* |
| 36C10X26R0054 |
| RESPONSE DATE/TIME/ZONE |
| 10-06-2026 10:00am EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 99 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339113 |
| CONTRACTING OFFICE ADDRESS |
| Enterprise Procurement Office |
Department of Veterans Affairs
5202 Presidents Court, Suite 103 Frederick MD 21703
POINT OF CONTACT*
Contract Specialist Jalima J. Jones Jalima.Jones@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| Nationwide |
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/opal/sac/index.asp |
| URL DESCRIPTION |
| VA | OALC | OPAL | SAC |
| AGENCY CONTACT’S EMAIL ADDRESS |
| Jalima.Jones@va.gov |
| EMAIL DESCRIPTION |
| Jalima.Jones@va.gov |
DESCRIPTION
Solicitation Number:
36C10X26R0054 Notice Type:
Combined Synopsis/Solicitation This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, “Streamlined Procedures for Evaluation and Solicitation for Commercial Items,” as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested, and a written solicitation will not be issued.
Solicitation number 36C10X26R0054 is issued for this combined synopsis/solicitation; this solicitation is being issued as a Request for Proposal (RFP). This combined synopsis/solicitation incorporates provisions and clauses in effect through Federal Acquisition Circular (FAC) 2026-01, dated 13 March 2026.
Requirement Description:
VA has a requirement to purchase the Medtronic EndoFLIP™ 300 system and related accessories and to deliver the same to its VA Medical Centers around the country. The EndoFLIP™ 300 provides real-time measurements of the pressure and dimensions of the esophagus during endoscopic evaluation and surgical procedures through Impedance Planimetry. Impedance Planimetry is described as a catheter-mounted, balloon-covered probe placed during a regular endoscopy using sedation and inflated to prespecified pressures. During inflation, pressure sensors along the balloon measure intraluminal pressure and cross-sectional areas within a gastrointestinal lumen or sphincter. The measurements are used to calculate a distensibility index (mm2/mm Hg) or compliance of the evaluated area.
A single award, Brand Name Only Requirements contract will be awarded for Medtronic EndoFLIP™ accordance with all terms, conditions, provisions, specifications, and schedule of this solicitation herein. Proposals shall contain the terms for cost/price. The Government reserves the right to award without discussions.
The associated North American Industrial Classification System (NAICS) code for this procurement is 339113 – Surgical Appliance and Supplies Manufacturing, Product Service Code: 6515 Medical and Surgical Instruments, Equipment, and Supplies. This procurement action is Unrestricted Full and Open.
This acquisition anticipates award of a single award Requirements contract in accordance with FAR Part 16.503 for Medtronic EndoFLIP™ 300 System and related accessories as identified in ATTACHMENT A – PRICE COST SCHEDULE - NX EQ PHYSIOLOGIC MOTILITY ANALYZERS ENDOFLIP. All interested companies shall provide a proposal for all Contract Line-Item Numbers (CLINs) listed in ATTACHMENT A – PRICE COST SCHEDULE - NX EQ PHYSIOLOGIC MOTILITY ANALYZERS ENDOFLIP. Only Medtronic products will be considered for award.
The ordering period is for one 12-month base year with four 12-month option years. Delivery is a FOB destination. Firm-Fixed Price Orders will be placed against this contract in writing and will provide the delivery locations, delivery dates and exact quantities.
The FAR provision at 52.212-1, Instructions to Offerors – Commercial Products and Commercial Services, applies to this acquisition including attached addenda to the provision.
The FAR provision at 52.212-2, Evaluation -- Commercial Products and Commercial Services Items, and the specific evaluation criteria as attached addenda also applies to this acquisition.
Clause 52.212-4, Terms and Conditions -- Commercial Products and Commercial Services, applies to this acquisition and a statement regarding any addenda to the clause. Addendum is attached.
All interested offerors must be registered in the System for Award Management (SAM) prior to submitting a quote. You may access SAM at https://sam.gov/SAM/.
Questions regarding this combined synopsis/solicitation are due via email by 10:00 AM Eastern Standard Time (EST) on September 29, 2026, to Contract Specialist, Jalima Jones at Jalima.Jones@va.gov and Contracting Officer Anthony Zibolski at Anthony.Zibolski@va.gov
No calls will be accepted. Proposals are due via email by 10:00 AM EST on October 06, 2026, to Contract Specialist, Jalima Jones at Jalima.Jones@va.gov and Contracting Officer Anthony Zibolski at Anthony.Zibolski@va.gov
1. SCOPE OF WORK
The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified Physiologic Motility Analyzers (Medtronic EndoFLIP™) product line as a candidate for a VA-wide (otherwise referred to as “national”) single Requirements contract award.
Physiologic Motility Analyzers determine the peristaltic smooth movement of some part of the digestive tract (e.g,. esophagus, stomach, small intestine, colon) and the intraluminal pressure exerted on its content. Most of these analyzers can evaluate motility in several areas on the intestinal tract using interchangeable dedicated catheters and accessories for different applications. Motility study results provide information necessary for prescribing treatment such as surgery, drug therapy, and biofeedback therapy.
The Contractor must demonstrate the ability to meet all requirements for the solicitation. The objective is to provide Medtronic EndoFLIP™ Physiologic Motility Analyzers to be used by VHA clinicians throughout the United States and its territories. The period of performance is for one 12-month base period with four 12-month option periods.
2. REQUIREMENT
This requirement will be brand name only for Physiologic Motility Analyzers which requires the offeror indicate that the product being offered is the Medtronic EndoFLIP™ and related accessories. The offeror must also clearly identify each item by brand name (Medtronic EndoFLIP™) including part/model number.
The following line-items comprise the Physiologic Motility Analyzers product line:
Contract Line-Item Number
Brand
Part Number
Description
| 0001 |
| Medtronic |
| 47229 |
| ENDOFLIPTM 300 SYSTEM |
| 0002 |
| Medtronic |
| 47230 |
| ENDOFLIPTM 300 EXISTING CUSTOMER PROMO (FOR EXISTING EF 100, 200 SYSTEMS |
| 0003 |
| Medtronic |
| 80488 |
| 1-DAY ON-SITE TRAINING |
| 0004 |
| Medtronic |
| 80489 |
| 2-DAY ON-SITE TRAINING |
| 0005 |
| Medtronic |
| EF-304 |
| ENDOFLIP 300 READER |
| 0006 |
| Medtronic |
| EF-305 |
| ENDOFLIP PRE-USE TUBE |
| 0007 |
| Medtronic |
| EF-322N |
| ENDO CATHETER 16CM NASAL TIP |
| 0008 |
| Medtronic |
| EF-325N |
| ENDO CATHETER 8CM NASAL TIP |
| 0009 |
| Medtronic |
| ES-310 |
| CATHETER 10MM ESO DILATION |
| 0010 |
| Medtronic |
| ES-320 |
| CATHETER 20MM ESO DILATION |
| 0011 |
| Medtronic |
| ES-330 |
| CATHETER 30MM ESO DILATION |
| 0012 |
| Medtronic |
| ES-ENDOFLIP3001 |
| ONE YEAR SERVICE PLAN |
| 0013 |
| Medtronic |
| ES-ENDOFLIP3002 |
| TWO-YEAR SERVICE PLAN |
| 0014 |
| Medtronic |
| ES-ENDOFLIP3003 |
| THREE-YEAR SERVICE PLAN |
| 0015 |
| Medtronic |
| LK-200 |
| PRE USE CHECK KIT FLIP |
The Department of Veterans Affairs (VA) is seeking vendors who can provide brand name Medtronic EndoFLIP™ 300 for Physiologic Motility Analyzers as listed above.
The following attachments are incorporated by reference. All criteria outlined in the attachments are applicable to this combined synopsis/solicitation.
See attached document: ATTACHMENT A - PRICE COST SCHEDULE - NX EQ PHYSIOLOGIC MOTILITY ANALYZERS.
See attached document: ATTACHMENT B - CONTRACT ADMINISTRATION - NX EQ PHYSIOLOGIC MOTILITY ANALYZERS 02.
See attached document: ATTACHMENT C - CONTRACT CLAUSES - NX EQ PHYSIOLOGIC MOTILITY ANALYZERS.
See attached document: ATTACHMENT D - SOLICITATION PROVISIONS - NX EQ PHYSIOLOGIC MOTILITY ANALYZERS.
See attached document: ATTACHMENT E - REPORTING TOOL - NX EQ PHYSIOLOGIC MOTILITY ANALYZERS.
See attached document: ATTACHMENT F - PAST PERFORMANCE REFERENCE - NX EQ PHYSIOLOGIC MOTILITY ANALYZERS.
See attached document: ATTACHMENT G - PAST PERFORMANCE QUESTIONNAIRE - NX EQ PHYSIOLOGY MOTILITY ANALYZERS 02.
See attached document: ATTACHMENT H - BNJ NX EQ PHYSIOLOGIC MOTILITY ANALYZERS EndoFLIP- FE.
| *= Required Field |
| Combined Synopsis/Solicitation Notice |
Combined Synopsis/Solicitation Notice
File details come from the government source that posted it. Updated .