36C10G24Q0046.docx
DOCX document 30 KB Posted
- Solicitation number
- 36C10G24Q0046
About this file
This document is a Sources Sought Notice issued by the U.S. Department of Veterans Affairs (VA) Strategic Acquisition Center, on behalf of the Veterans Health Administration (VHA), for Circulatory Assist Units: Intra-Aortic Balloon.
The VA is seeking a qualified source to provide Getinge brand name or equal Circulatory Assist Units, Intra-Aortic Balloon on an agency-wide basis. The anticipated period of performance is for one 12-month base period with four 12-month option periods. The VA intends to award a Requirements Contract with Firm-Fixed Price orders. The associated NAICS code is 339113 Surgical Appliance and Supplies Manufacturing. Vendors must be registered in SAM and meet the 800-employee size standard. The VA has identified specific salient characteristics the products must meet, including eliminating 99.99% of pathogens, automatic/semi-automatic/manual modes, multiple triggering modes, event/history log, pump rate up to 200 bpm, auto condensation removal, display of parameters, and QRS indicator. Vendors must provide technical literature demonstrating compliance with the salient characteristics and may propose additional beneficial product configurations. The VA is also requesting information on the vendor's ability to provide an annual service plan, uninterrupted national supply, and company details.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C10G24Q0107 0002.pdf | ||
| ATTACHMENT G - PAST PERFORMANCE QUESTIONAIRE - NX EQ Circulatory Assist Units Revised 8.8.24.docx | DOCX document | |
| ATTACHMENT D - SOLICITATION PROVISIONS - NX EQ Circulatory Assist Units Revised 8.824.docx | DOCX document | |
| 36C10G24Q0107 0001.pdf | ||
| 36C10G24Q0046 0001.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| BNOE NX EQ Circulatory Assist Units: Intra-Aortic Balloon |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 22408-2697 |
| SOLICITATION NUMBER* |
| 36C10G24Q0046 |
| RESPONSE DATE/TIME/ZONE |
| 04-05-2024 03:30PM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 99 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339113 |
| CONTRACTING OFFICE ADDRESS |
| U.S. Department of Veterans Affairs |
OPAL | Strategic Acquisition Center
10300 Spotsylvania Ave | STE 400 Fredericksburg VA 22408-2697
POINT OF CONTACT*
Contract Specialist Deidre Parker Deidre.Parker@va.gov 202-603-4420
PLACE OF PERFORMANCE
ADDRESS
Nationwide
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/opal/sac/index.asp |
| URL DESCRIPTION |
| VA | OALC | OPAL | SAC |
| AGENCY CONTACT’S EMAIL ADDRESS |
| Deidre.Parker@va.gov |
| EMAIL DESCRIPTION |
| Deidre.Parker@va.gov |
DESCRIPTION
1.0 DESCRIPTION
The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Circulatory Assist Units, Intra-Aortic Ballon product line as a candidate for a VA-wide (otherwise referred to as “national”) single Requirements contract award.
The Department of Veterans Affairs’ (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources.
The SAC in conjunction with VHA is seeking a qualified source to provide Getinge® brand name or equal Circulatory Assist Units, Intra-Aortic Ballon on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Circulatory Assist Units, Intra-Aortic Ballon to VA medical centers and facilities throughout the United States.
The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.
The associated North American Industrial Classification System (NAICS) code for this procurement is 339113 Surgical Appliance and Supplies Manufacturing and the associated size standard is 800 employees. The FAR Provision found at 52.204-7(b)(1) requires that “All interested Offerors must be registered in SAM prior to submitting an offer or quotation.” You may access the SAM website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission.
This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.
2.0 SCOPE -
Circulatory Assist Units: Intra-Aortic Balloon produce mechanical counter pulsation to reduce the afterload to the heart and increase coronary and cerebral blood flow. These devices consist of an inflatable balloon catheter, which is placed in the aorta attached to an external unit that includes a pneumatic system, regulating the automated inflation and deflation of the balloon in synchronism with the cardiac cycle; they include monitors of the physiologic parameters of the patient (e.g., heart rate, arterial pressure) and also of balloon pressure and volume. The inflated intra-aortic balloon forces the blood toward the heart during each diastolic phase of the cardiac cycle. Intra-aortic balloon circulatory assist units are used to improve cardiovascular functioning during cardiac failures that constitute life-threatening emergencies.
The Contractor must demonstrate the ability to meet all requirements for the solicitation. The objective is to provide Circulatory Assist Units: Intra-Aortic Balloon to be used by clinicians throughout the VA medical centers and facilities.
The following Contract Line Items are being considered:
| Contract Line Item# |
| Part Number |
| Description |
| BASE YEAR |
| YEAR 1 |
| YEAR 2 |
| YEAR 3 |
| YEAR 4 |
| 0001 |
| 0998-00-0800-53 |
| Cardiosave Hybrid Intra-Aortic Balloon Pump includes accessory kit (D0020-00-0480-01), 2 Li-Ion battery pack (D146-00-0097), Helium Tanks (D075-00-0024-03) and CARDIOSAVE Li-Ion Single Battery Transport PART NUMBER (D202-00- 0206-01) (Protective transport case required by fed regs). MANUFACTURER PART NUMBER (D202-00- 0206-01) - charger integral to Cardiosave cart |
| 23 |
| 26 |
| 28 |
| 12 |
| 10 |
| 0002 |
| 0998-00-0803 |
| Cardiosave Trainer |
| 10 |
| 12 |
| 14 |
| 6 |
| 5 |
| 0003 |
| ZSUSBZCDSVPOSEW |
| CRDSVE - GCare Preventative - EW 1Y |
| 5 |
| 5 |
| 9 |
| 4 |
| 3 |
| 0004 |
| ZSUSSVCDSVPOSEW |
| CRDSVE - GCare Professional - EW 1Y |
| 5 |
| 5 |
| 9 |
| 4 |
| 3 |
| 0005 |
| ZSUSGDCDSVPOSEW |
| CRDSVE - GCare Premium - EW 1Y |
| 5 |
| 5 |
| 9 |
| 4 |
| 3 |
The Department of Veterans Affairs (VA) is seeking vendors who can provide Getinge® brand name or equal Circulatory Assist Units, Intra-Aortic Ballon as listed above or equal commodities which meet all the following salient characteristics.
| SC # |
| SALIENT CHARACTERISTICS |
| METHOD OF EVALUATION |
| APPLICABLE CLINS |
| VENDOR’S PROVIDE PAGE # WHERE EACH SC IS MET IN YOUR TECHNICAL LITERATURE |
| SC 1 |
| Must Eliminate (Kill) 99.99% Pathogens (Bacteria) |
| Literature Review |
| 0001 |
| SC 1 |
| Automatic, semiautomatic or manual modes of operation |
| Literature Review |
| 0001 |
| SC 2 |
| Multiple triggering modes |
| Literature Review |
| 0001 |
| SC 3 |
| Event/History Log capable |
| Literature Review |
| 0001 |
| SC4 |
| Maximum Pump Rate of 200 bpm |
| Literature Review |
| 0001 |
| SC 5 |
| Auto condensation removal capable |
| Literature Review |
| 0001 |
| SC 6 |
| Display with parameters (e.g., ECG, heart rate, arterial pressure) |
| Literature Review |
| 0001 |
| SC 7 |
| QRS Indicator |
| Literature Review |
| 0001 |
For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics (SC) specified above.
The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the OEM and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.
Responses to this Sources Sought Notice shall include the following:
1. Does vendor offer an annual service plan, Yes or No?
2. If Yes:
a. What does the plan cover?
b. Does plan cover software updates only?
c. Does the plan cover parts repair or replacement only?
d. Does the plan cover both software and parts?
3. Vendor are requested to provide documentation that shows information on their service plan.
4. Is the service provided by the OEM or a subcontractor?
5. Full name and address of company
6. DUNS number/ CAGE Code/ SAM UIE
7. Business Size
8. Manufacturer or Distributor
a. If distributor provide full name, business size and address of manufacturer.
9. Country of Origin designation for all products
10. Ability to provide uninterrupted supply of products on a national scale.
11. Technical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.
12. Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.
Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
File details come from the government source that posted it. Updated .