36A79720Q0010-0001002.xlsx

XLSX spreadsheet Posted

Attached to
6525--FEBRUARY 2020 CONSOLIDATION Federal contract opportunity
Solicitation number
36A79720Q0010
Issued by
Department of Veterans Affairs National Acquisition Center

About this file

36A79720Q0010 0001 TEAM A - Vendor Q_A Feb 2020 Consolidation.xlsx

View the file

Other files for this federal contract opportunity

Other files attached to 6525--FEBRUARY 2020 CONSOLIDATION, newest first.
File Type Posted
36A79720Q0010-0002004.xlsx XLSX spreadsheet
36A79720Q0010-0002000.docx DOCX document
36A79720Q0010-0002003.zip ZIP file
36A79720Q0010-0002001.pdf PDF
36A79720Q0010-0002006.zip ZIP file
36A79720Q0010-0002005.zip ZIP file
36A79720Q0010-0002002.pdf PDF
36A79720Q0010-0001011.zip ZIP file
36A79720Q0010-0001004.zip ZIP file
36A79720Q0010-0001007.zip ZIP file
36A79720Q0010-0001009.zip ZIP file
36A79720Q0010-0001010.zip ZIP file
36A79720Q0010-0001005.zip ZIP file
36A79720Q0010-0001003.zip ZIP file
36A79720Q0010-0001006.zip ZIP file
36A79720Q0010-0001001.pdf PDF
36A79720Q0010-0001008.zip ZIP file
36A79720Q0010-0001000.docx DOCX document
36A79720Q0010-0001012.zip ZIP file
36A79720Q0010-017.zip ZIP file
36A79720Q0010-020.pdf PDF
36A79720Q0010-008.pdf PDF
36A79720Q0010-005.pdf PDF
36A79720Q0010-010.zip ZIP file
36A79720Q0010-007.xlsx XLSX spreadsheet
36A79720Q0010-006.pdf PDF
36A79720Q0010-024.zip ZIP file
36A79720Q0010-021.pdf PDF
36A79720Q0010-014.zip ZIP file
36A79720Q0010-023.zip ZIP file
36A79720Q0010-026.xlsx XLSX spreadsheet
36A79720Q0010-012.zip ZIP file
36A79720Q0010-011.pdf PDF
36A79720Q0010-022.pdf PDF
36A79720Q0010-019.pdf PDF
36A79720Q0010-016.zip ZIP file
36A79720Q0010-025.zip ZIP file
36A79720Q0010-015.zip ZIP file
36A79720Q0010-004.docx DOCX document
36A79720Q0010-029.pdf PDF
36A79720Q0010-028.pdf PDF
36A79720Q0010-013.zip ZIP file
36A79720Q0010-009.zip ZIP file
36A79720Q0010-027.pdf PDF
36A79720Q0010-018.zip ZIP file
Show all 45

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

February 2020 Team A

Consolidation Report
HTME VISNConsolidation PeriodConsolidation TypeRequisition Number in ActionEquipment TypeStation
VISN 21: VA Sierra Pacific NetworkFEB 2020CONSOLIDATION459B00005XR MAMMO459 HONOLULU, HI
VISN 1: VA New England Healthcare SystemFEB 2020CONSOLIDATION523B61009NM SPECT CT523 W ROXBURY, MA
VISN 12: VA Great Lakes Health Care SystemFEB 2020CONSOLIDATION537B98023XR CT537 CHICAGO, IL
VISN 10: VA Healthcare System of OhioFEB 2020CONSOLIDATION541B93021XR MAMMO541 CLEVELAND, OH
VISN 10: VA Healthcare System of OhioFEB 2020CONSOLIDATION583B01055XR RAD583 INDIANAPOLIS, IN
VISN 10: VA Healthcare System of OhioFEB 2020CONSOLIDATION583B01056XR RAD583 INDIANAPOLIS, IN
VISN 15: VA Heartland NetworkFEB 2020CONSOLIDATION589B00016NM SPECT CT589 KANSAS CITY, MO
VISN 21: VA Sierra Pacific NetworkFEB 2020CONSOLIDATION612B96007XR MRI612 REDDING, CA
VISN 5: VA Capitol Health Care NetworkFEB 2020CONSOLIDATION613B91030XR CT613 MARTINSBURG, WV
VISN 21: VA Sierra Pacific NetworkFEB 2020CONSOLIDATION640B94013XR MRI640 PALO ALTO, CA
VISN 21: VA Sierra Pacific NetworkFEB 2020CONSOLIDATION640B94014XR MRI640 PALO ALTO, CA
VISN 22G: VA Southwest Health Care NetworkFEB 2020CONSOLIDATION644B08013XR CT644 PHOENIX, AZ
VISN 22G: VA Southwest Health Care NetworkFEB 2020CONSOLIDATION644B08015XR RF644 PHOENIX, AZ
VISN 22G: VA Southwest Health Care NetworkFEB 2020CONSOLIDATION644B08016XR RAD644 PHOENIX, AZ
VISN 22G: VA Southwest Health Care NetworkFEB 2020CONSOLIDATION644B08017XR RAD644 PHOENIX, AZ
VISN 21: VA Sierra Pacific NetworkFEB 2020CONSOLIDATION662B00011XR CT662 SAN FRANCISCO, C
VISN 8: VA Sunshine Healthcare NetworkFEB 2020CONSOLIDATION673B40006XR MRI673 TAMPA, FL

Q&A

TeamService Responsible for providing answersRequisition NumberQUESTIONSANSWERS
ANAC-HTME Team A600B00003Was not included in the actual consolidation listing – was this cancelled?Requirement was cancelled.
ANAC-HTME Team A600B00003Benchmark was not included in the releaseRequirement was cancelled.
ANAC-HTME Team AResponse Submission3.2 Multi-unit discounts shall be nationwide, and based on the total number of line items purchased from this RFQ.

3.3 Multi-unit discounts shall be applied by equipment modality for the entire consolidation.

The above two phrases seem to conflict with each other. Could you provide clarification on wheter multi-unnit discounts shall be applied by (a) the total number of awards by specific modality in the entire consolidation, or (b) by the total number of awards for all modalities combined in the entire consolidation?This is the same language as in the past Consolidations and it is referencing that the multi-unit discounts are applied by equipment modality (total line items for that modality); for all of the VISNs that are purchased and not confined to certain locations.
ANAC-HTME Team AResponse Submission1.Please clarify file naming structure. Examples throughout the instructions lack the special character punctuation (i.e. “-“ and “,”) that is specified in section 7.3.3.Please do not use "-" or "," when listing out the PO/Requsition number in the file name
ANAC-HTME Team AResponse Submission2.Section 2.8.g states, “No travel expenses for any VA employees will be included in any HTME equipment or training order.” Redacted benchmark quotes however do show travel and training included in the offering (i.e. 644-B08014 XR US). Knowing that education will be purchased at the time of need, will NAC be requiring a change to all training quotations to assure that travel, per diem, etc. is no longer grouped into the training quote? If not, that inclusion of travel related benefit does become a selection criterion. How will the NAC ensure such offerings do not factor into the station’s evaluation for selection?Although the NAC will not award this training along with the equipment, it is imperative that the customer is informed that this training is available. Vendors must demonstrate that they can provide any required off-site training, therefore off-site training should be quoted as an optional item. Off-site training will be purchased at the time of need via a modification (if the original order remains open) or via a separate order. No travel expenses for any VA employees will be included in any HTME equipment or training order.

Technical training information to include detailed information about the curriculum and length of the biomedical technical training required for each equipment type.

ANAC-HTME Team AResponse SubmissionHow do we know when TURNKEY Construction is required as a part of the response? Will that be clearly indicated in the GENERIC SPECIFICATION?The solicitation is for equipment only. If extended installation is required it will be communicated after delivery order award and be incoporated via Modification.
ANAC-HTME Team AResponse SubmissionIn some of the line items, the word “REDACTED” appears, what does that mean, relative to a specific line item?Redacted means it is a redacted benchmark quote and not a generic technical specifications
ANAC-HTME Team AConsolidation Schedule of Milestone datesWill the Milestone dates for Team A be adjusted/extended since the Solicitation was delayed in being posted from 3/25/20 to 3/30/20?No, milestones remain as posted.
ANAC-HTME Team AInstructions to OfferorsPer the Instructions to Offerors: 1)There are 2 Main folders, Information and Quotes-Workups-Matrix. 2) Information folder contains subfolders for each equipment type.

What was provided: 1) There are 3 Main folders, 6550, Information, Quotes-Workups-Matrix. 2) Information folder does NOT contain any subfolders

Should we create equipment subfolders in the Information folder? Should the 6550 form be saved in both the 6550 and Information folders?The folders zip file will be corrected via Amendment 00001
ANAC-HTME Team AInstructions to OfferorsPlease note that in the Instructions to Offerors, the address for overnight deliveries is referencing the Sept 2019 ConsolidationA corrected Instructions of Offerors will be provided via Amendment 0001
ANAC-HTME Team AResponse SubmissionDue to service impact of COVID-19, mail and Fedex seem to be experiencing delays. Would the NAC consider other options to submit responses, such as email? If our submission is late due to unforeseen delays with mail/Fedex, will there be a grace period for submission receipt?Sending in a CD with the quotes is still going to be the same process as always. Someone will pick up the quotes from the facility in the event that the stay-at-home is still in place. If there is an issue with delays, we will deal with that when the time comes, however, trying to overnight something on the 12th to get there on the 13th would be advised against.
ANAC-HTME Team AResponse SubmissionCan you please confirm the VA/National Acquisition Center at address listed for overnight deliveries is open for receipt of Fedex deliveries.Yes, it is open.
ANAC-HTME Team AResponse SubmissionFedex states they have suspended Signature Required for most shipments. If we are unable to get a signature, who should we contact to confirm receipt of our submission?Consolidation Manager, Iliana Jorge
AVISN 01523B610092.c. Caudal Tilt

Question: The Caudal Tilt is a restrictive requirement provided by one vendor, please remove this minimum requirement.

2.g. Automatic collimator changer Question: The automatic collimator changer is a restrictive requirement for a specific vendor. Please change this requirement to, Automatic or Semi-Automatic collimator changer or remove the requirement.

5.h. Integrated collimator changer Question: The integrated collimator changer is a restrictive requirement for a specific vendor. Please change this requirement to, “Fast, efficient and reliable collimator exchange process” or remove the requirement.

5.i. ECG Triggering software for CT and SPECT Question: Please change this requirement to “ECG triggering software for SPECT/CT.” The CT is typically not triggered, or gated, in a SPECT/CT with a non-diagnostic CT.

5.q. Auto QC Question: This is a restrictive requirement for a specific vendor. Please change this requirement to: Fast, efficient and reliable Quality Control process, or remove the requirement. 2.c. Caudal Tilt Clinical staff said that this is required to meet their clinical need.

2.g. Automatic collimator changer Changed to “Automatic or Semi-Automatic collimator changer”

5.h. Integrated collimator changer changed to, “Fast, efficient and reliable collimator exchange process”

5.i. ECG Triggering software for CT and SPECT Changed to “ECG triggering software for SPECT/CT.”

5.q. Auto QC Changed to: “Fast, efficient and reliable Quality Control process” A VISN 05 613B91030 2.j. Full UPS Question: Please clarify this requirement to full or partial UPS. If you are requesting a full UPS (ability to scan patients without power) please confirm that the facility has the room, the correct HVAC and power to install this unit.

3.a. Minimum acquisition workstation monitor size 27”.

Question: To allow for full competition, please change this spec to minimum of 19” monitor. 2.j. Provide a UPS that provides the ability to do one full scan when not on power

3.a. specification changed to 19 - updated specifiations and compliance matrix provided A VISN 05 613B91030 Need more Trade-in information Serial nuber, Make and Model. As listed in the specifications:

Manufacturer: Canon/Toshiba Model: Aquilion 64 EE/Asset Number: 43504 Serial Number: JDA10Z2215

AVISN 08673B40006Any MR monitoring needs at this site such as the Invivo MR 400 or other?
Please confirm - No Breast imaging/breast coil needs?No Breast Imaging needed.
AVISN 08673B40006This is a construction related specification: b. Fire suppression system meeting NFPA standards and all applicable codes (the system must connect to the facility fire alarm system). Please confirm this is not applicable.This is applicable to an MRI.
AVISN 08673B400061d.Is this cm? Or mm? Maximum FOV? OR minimum?

1e. Is this really 75 T/m/s? NO vendor today offers this slow slew rate. Minimum should be at least 155 T/m/s. There is also no specification for minimum Aplitude. This should be a minimu of at lease 34 mT/m.

1f. 8 channel minimum is very low. Typical would be at leaset 32 channel.

1h. Is this for the entire system or just the workstation? 1200 seconds is 20 minutes and would require a massive UPS if for the entire system. Typical UPS is 7 min or 420 seconds. Would require more space for all the batteries if 1200 seconds.

1j. Is this requiremetn for the magnet? 1d.-cm adjusted to maximum FOV 50cm.

1e.- adjusted to minimum slew rate 155 T/m/s 1.f- adjusted to minimum number of channels 32 1h.adjusted to minimum UPS time at full functionality 10 Min.

1.yes A VISN 08 673B40006 Technical Requirements 1.d. Minimum field of view [cm] 500 Question: please change this specification to Minimum FOV 10 cm or Maximum FOV 50 cm.

1.g. Minimum patient table load capacity 550lbs.

Question: To allow for full competition, please change this specification to 500lbs.

1.h. Minimum UPS time at full functionality – 1200 Question: Does the facility want a UPS that will allow the scan to continue with a power loss (full UPS) and if yes, please change the requirement to 10 min. The 1200 seems to be an error. Does the facility have the facility room and power requirements for a full UPS, or should this be changed to a partial UPS, (110v only) will cover computers only for a controlled shutdown – lasting about 10 min.?

Table Requirements 4.a. Motorized Question: Please remove this requirement. All systems have tables that are motorized to move the patient into the gantry. Some vendors require a motorized detachable table because the table is heavy and difficult to handle. This is an option that is very specific and should be removed from the minimum requirements.

4.b. Adjustable height when table is attached and detached.

Question: Please remove the word, “detached”, from this requirement. 1.d-adjusted to maximum FOV 50cm.

1.g- adjusted to minimum patient table load capacity 500lbs.

1.h- adjusted to minimum UPS time at full functionality 10 Min.

4.a-Motorized moved to the Added Value section 4.b-Detached moved to the Added Value section

AVISN 10583B01055Compliance matrix is corrupted and can't be openedUpdated Matrix provided
AVISN 10583B01055We are having issues accessing the correct Compliance Matrix for this requisition. The Excel document that was included in the zip file appears to be an internal VA document and does not contain specifications for this requisition. Can you please provide the correct Compliance Matrix?Updated Matrix provided
AVISN 10583B01055The matrix is actually their planning worksheet, can you please provide the correct document? The benchmark shows for 2 systems. Do we quote 2 or will they create another Requisition #?Updated Matrix provided

Brownsburg CBOC is quantity of 2 Radiographic X-Ray rooms of the same technical specifications. Please quote two systems utilize PO 583-B01055 for both rooms.

AVISN 10583B01055
583B01056Section 1 seems to indicate two fixed detectors and one wireless detector. Please confirm how many detectors are required of each type.

Please expand item 2n to at least 21 inches, as 20 inches is unduly restrictive.

Items 4c and 4f - Please reduce to minimum of 256GB, as there appears to be no clinical need for 1TB of hard drive size. Images are taken and then sent to PACS. 256GB holds over 22,000 images.

"Version/platform long-range plan" - Can NAC please expand on the type of information being requested in this section including examples of how one meets a minimum requirement for having a version/platform long-range plan?

Please confirm no trade-ins.

Two fixed detectors and 1 wireless detector

Changed specification to 21 inches.

Changed to 256GB

Version/platform long-range plan is in the Added Value section therefore it is not a requirement. Information provided can include details about the long range plans for the support, upgrades, etc. for the platform being proposed.

Confirmation there are No Trade Ins.

AVISN 10583B01055
583B01056Per the equipment specifications PDF for the Indy VA. The Brownsburg CBOC location is showing a quantity of 2, while the Terra Haute CBOC location is showing a quantity of 1. The question is that we are only showing two Xray Rad line items for the Indy VA consolidate buy. With this being a total of 3 radiographic rooms, what obligations numbers should we use for all the quotes? Would we just reuse the Brownsburg obligation number twice? Will that be appropriate for this response?Brownsburg CBOC is quantity of 2 Radiographic X-Ray rooms of the same technical specifications. Please utilize PO 583-B01055 for both rooms.

Terre Haute COBIC has a quantity of 1 Radiographic X-Ray room. Please utilize PO 583-B01056 for that room.

A VISN 12 537B98023 1.e. Table height range from floor [cm] 49-92 Question: In order to allow for full competition please change this minimum requirement to 55-103cm.

2. j. Gantry- or ceiling-mounted contrast injector with proven reliable synchronicity.

Question: This requirement conflicts with the requirements overview that stated the injectors should not be replaced. Please confirm if vendors should include a new injector.

2.k. Full UPS Question: Please clarify this requirement to full or partial UPS. If you are requesting a full UPS (ability to scan patients without power) please confirm that the facility has the room, the correct HVAC and power to install this unit.

3. Workstation Requirements Question: Please confirm that this requirement is for a post processing workstation? Would you prefer a workstation or a thin client server?

3.a. Minimum acquisition workstation monitor size 24”.

Question: To allow for full competition, please change this spec to minimum of 19” monitor. 1.e. Clinical requirement and multiple vendors can meet therefore this specification will remain as is.

2.j. No new injector - this has been removed from the specifiations 2.k. Full UPS

3. Post processing, workstation 3.a. Clinical requirement and multiple vendors can meet therefore this specification will remain as is.

A VISN 12 537B98023 Would you be able to also send over:

3. Original Year of Manufacture

4. Gantry Count

5. Tube Model + Year of Manufacturer

6. Tube Count in seconds

7. Removal Path (i.e. system will come out through doors or will require wall removal?

8. Service on system - OEM Full service? Biomed only? Third Party? No additional information about the unit will be provided at this time other then that it is serviced by the OEM.

A VISN 15 589B00016 Requirements Overview Overview states the requirement is for a SPECT/CT unit used for “…low dose non-diagnostic CT for anatomic localization and CT attenuation correction.”

Question: Please clarify if this request is for a SPECT/CT with a low-dose, non-diagnostic CT or is the requirement for a SPECT/CT with a diagnostic CT.

Technical Requirements 1.a. Minimum number of slices 16 Question: If this requirement is for a non-diagnostic SPECT/CT please change the minimum requirement to a 4 slice CT or update the requirements overview and section 2.a. to a diagnostic SPECT/CT.

1.l. Maximum system dimensions [in] 92 in x 54 in x 92 in Question: Please confirm that this specification is for the full system? Please clarify the room dimensions so we can ensure our product will fit.

1. m. Maximum system weight [lbs.] 9,000 lbs.

Question: This is a restrictive requirement, please change the weight to 10,000.

Additional Specifications 2.a.SPECT CT Type – Non-diagnostic Question: This specification identifies a low dose non-diagnostic CT requirement, however many of the specifications are for a SPECT/CT that has diagnostic quality . Please clarify the requirement the requirement.

2.c. Cephalic and caudal tilt.

Question: Cephalic and caudal tilt is a restrictive requirement provided by one vendor. Please remove this as a minimum requirement.

2.h. Automatic collimator changer Question: Automatic Collimator Changer is a restrictive requirement for a specific vendor. Please change this requirement to, “Automatic or Semi-Automatic Collimator Changing,” or remove this requirement

3.k. Supplemental in-room SPECT acquisition control Question: This is an unduly restrictive requirement for one vendor not required for all vendors please remove this requirement.

3.l. Professional interpretation workstation hardware Question: Please clarify this requirement. Are you requesting a second post processing workstation, a post processing server with clients or is the intent to confirm the workstation included in the configuration is capable of “professional interpretation” functionality?

4.m. 3D/CTA fusion overlay (Advanced Applications) Question: Please confirm this is a required option. This is normally a CT application.

Software Requirements

5.h. Integrated collimator changer Question: This is an unduly restrictive requirement for one vendor not required for all vendors please remove this requirement. 5.i. ECG triggering software for CT and SPECT Question: The CT is typically not triggered, or gated, in a SPECT/CT with a non-diagnostic CT. Please change this requirement to “ECG triggering software for SPECT/CT,” or remove this requirement.

5.k. List mode acquisition software Question: List mode is normally required only if you're doing research and may require a higher end system than the specs indicate. Please explain the clinical requirement to understand how we can fulfill the need.

5.v. Auto QC Question: Auto QC is a restrictive requirement for a specific vendor. Please change this to “Fast, efficient and reliable Quality Control process,” or remove this requirement.

5.x. Oncology/Treatment Planning Positioning/Pallet Question: This is normally a PET/CT requirement, please remove this from as a minimum requirement.

Additional Questions:

Question: Is the customer requesting CT dose reduction software?

Question: Does the customer need Metal Artifact Reduction included in the offer?

1.a. Minimum number of slices is 16 as outlined in the technical specification.

1.l. Maximum full system dimensions is 92 in x 54 in x 92 in 1.m. Changed tech spec to Maximum System Weight 10,000.

2.a. Clinical purpose is for non-diagnostic. Requirement to remain 16 slices 2.c. Changed tech spec - Remove Cephalic and caudal tilt as requirement 2.h. Changed tech spec to Semi-Automatic collimator changer 3.k. Technical specification will not change.

3.l. Changed tech spec - One acquisition and one post processing workstation 4.m. Changed tech spec - Removed specification 3D/CTA fusion overlay (Advanced Applications) 5.h. Addressed on 2.h.

5.k. List-mode software allows for refinement of myocardial perfusion SPECT by interrogating particular data from selected cardiac cycles.

5.v. Changed tech spec to - Fast, efficient and reliable Quality Control process 5.x. Changed tech spec – removed Oncology/Treatment Planning Positioning/Pallet

Additional questions:

Question: Is the customer requesting CT dose reduction software? Offer as an option

Question: Does the customer need Metal Artifact Reduction included in the offer?

Offer as an option A VISN 15 589B00016 SPECT CT type: It states Non-Diagnostic – what do they mean by that?

You've listed required specs for: energy range 60-560KeV - What studies are you looking to perform? Anythig over 511+ is considered, PET energy. Our system covers a range from 4-200KeV.

Room size: 92"x54"x92" - this space seems small for any SPECT CT system on the market, can you verify these are the correct room spec requirements? (7'6" x 4'5" x 7'6")See above
AVISN 15589B00016a. In section 3 a-F. Confirm that the customer wants a separate Acquisition and separate Processing/Reading workstation.
b.We usually configure the system with 1 work station that does both the acquisition and processing reconstruction.
c.What is the Reading Physician’s workflow? If the Physicians need a Reading solution can we add the Cardiac, Oncology and Neurology software to their existing Siemens Syngo Via Thin Client Server? In this case, the Physicians would use their PACS work station and monitor. How many concurrent users. Please advise.
d.In section 2A. the specification is for a non-diagnostic CT, but it also calls for a 16 slice, please clarify
e.In section 5T lists Thin Client as a requirement, can we confirm that is the Syngo Via, please clarify?
f.In section 2 K & I asks for a external ECG and Monitor with stand, will an internal ECG also meet the requirement?
g.We can also provide an Internal ECG & Monitor on the scanner for a lower cost and more convenient workflow. Please advise.
h.In section 1J asks for Low Energy Ultra High Resolution collimators, please advise that they do not want to replace this with a Pin Hole collimator?
i.In section 3J, asks for a mounting system for the monitor in the scan room. Are they referring to a desk in the control room for the acquisition/processing work station.?
j.In section 3K, asks for a supplemental in-room SPECT acquisition control, need more calcification
k.In section 5X asks for a Oncology/Treatment Planning Positing Pallet. Treatment planning can not be done on a SPECT/CT. Please advise.
l.In section F. What is the current scan seconds on the current CT of the Symbia T to be traded in.A. Repeat question – see above

B. Repeat question - See above.

C. Up to 7 concurrent users D. Repeat question - See above.

E. Confirmed Syngo Via F. Internal should be accessible for patient monitoring on the bed/table.

G. Repeat question - See above.

H. No pin hole desired.

I. Both J. This is a request for an attached P-scope.

K. Repeat question - See above.

AVISN 21459B00005•It is Screening only?
•Diagnostic? If so, are you doing needle locs?
•Biopsy? If so, what is your vacuum assist system?
•Do you need the biopsy chair? (on AWS, would you like double screens if you are doing biopsy, most facilities like this for diagnostic and biopsy)
•Reading workstation needed?
•What is the PACS?
•Is your PACS upgraded to latest mammo module for tomo?
•Please send in pics of current mammo system and the serial number. <<<• It is Screening only? No

• Diagnostic? If so, are you doing needle locs? Diagnostic yes, no needle locs.

• Biopsy? If so, what is your vacuum assist system? No

• Do you need the biopsy chair? No (on AWS, would you like double screens if you are doing biopsy, most facilities like this for diagnostic and biopsy) No

• Reading workstation needed? No

• What is the PACS? Philips IntelliSpace

• Is your PACS upgraded to latest mammo module for tomo? Yes

• Please send in pics of current mammo system and the serial number. See attached for photos and serial numbers.

A VISN 21 612B96007 I see that there are Mobile Trailer requirements. We wish to inquire if a modular building is an option?

1. We wish to inquire if a modular building is an option?

2. Additionally, do they plan to move the trailer, or if it is intended to reside at one location?1.No modular building option is required.
2.The trailer will reside at one location.
AVISN 21612B960071c. Shouldn't this be Maximum Field of View?
1g. Is this weight for magnet only?1c. Yes, that is the Max Field of View.

1g. Yes, this is the weight for the magnet only.

A VISN 21 612B96007 Technical Requirements 1.c. Minimum field of view [cm] 55 Question: To allow for full competition, please change this specification to 50cm.

1.f. Minimum patient table load capacity 550lbs.

Question: To allow for full competition, please change this specification to 500lbs.

1.g. Maximum system weight 3060 lbs.

Question: Maximum system weight appears to be an error, please change this requirement to Magnet Weight: 7500 lbs.

Table Requirements 5.b. Motorized Question: Please remove this requirement. All systems have tables that are motorized to move the patient into the gantry. Some vendors require a motorized detachable table because the table is heavy and difficult to handle. This is an option that is very specific and should be removed from the minimum requirements. 1c. Agreed. Min FOV changed to 50 cm.

1f. Agreed. Min patient table capacity changed to 500 lbs.

1g. Agreed with changes. Maximum System weight changed to Maximum Magnet Weight: 7500 lbs.

5b. Agreed. Motorized requirement moved to added value section

AVISN 21640B94013
640B94014Technical Requirements

1.i. Minimum UPS time at full functionality – 6 Hours Question: Does the facility want a UPS that will allow the scan to continue with a power loss (full UPS) and if yes, please change the requirement to 10 min. A UPS just keeps the system functional until a generator starts, or power is restored. Does the facility have the facility room and power requirements for a full UPS, or should this be changed to a partial UPS, (110v only) will cover computers only for a controlled shutdown – lasting about 10 min.?

Table Requirements 5.b. Motorized Question: Please remove this requirement. All systems have tables that are motorized to move the patient into the gantry. Some vendors require a motorized detachable table because the table is heavy and difficult to handle. This is an option that is very specific and should be removed from the minimum requirements. 1.h. UPS time has been changed to 600 seconds. This is full functionality, not just workstations Table requirements remain as is. The requirement is for a table that is motorized to move the patient into the gantry, as described in the question, and also detachable and dockable. The detached table does not need to be motorized to move it around with the patient on it.

AVISN 21640B94013
640B940141H. Minimum UPS time at Full Functionality (s) - 6 hours ------- Is the requirement of 6 hours for the workstation or the entire operational system at peak operation? What if any clarification can be provided here?

Do they require de-installation of an existing MR?

1i. Minimum UPS time at full funcitionality (s) - Is this requirement for the entire system to allow full scanning or just for the workstation? 1.h. UPS time has been changed to 600 seconds. This is full functionality, not just workstations There is no existing MR to de-install 1i. UPS time has been changed to 600 seconds. This is full functionality, not just workstations A VISN 21 662B00011 1d. Is the 80cm requirement referring to a calibrated or extrapolated FOV? Please clarify 2k. Seek clarification of whether the intent of the requirement is to propose a UPS for the entire system including the gantry?

3c. Seek clarification on whether the intent of the requirement is for a 2nd operator's console or an advanced visualization workstation?

3e/f. Please clarifly if the intent of the requriemetn is for redundant UPS systems for both acquisition & post processing workstations given requirement 2k Trade-in: Please provide additional information to assist in determining system value (i.e. date of installation, total rotations/scan seconds on the gantry, date of last tube replacement, rotation/scan seconds on current x-ray tube, general condition, etc). 1d. 80cm calibrated FOV 2k. CT System will be plugged into back-up generator. UPS will be required to bridge an approximate 10 second gap till the generator power kicks in.

3c. Advanced processing workstation 3e/f. Do not require a redundant UPS Trade in: Installation Date: Mar 30, 2011 Tube Replacement Dates: 5/30/19 A VISN 21 662B00011 1.d. Minimum detector field of view [cm] 80.

Question: Please clarify this requirement. If the requirement is Minimum scan field of view, please change to 50 cm. If the requirement is Minimum detector coverage please change to 80 mm.

2.k. Full UPS Question: Please clarify this requirement to full or partial UPS. If you are requesting a full UPS (ability to scan patients without power) please confirm that the facility has the room, the correct HVAC and power to install this unit.

3.a. Minimum acquisition workstation monitor size 20”.

Question: To allow for full competition, please change this spec to minimum of 19” monitor.

Additional Question: The specification does not require Metal Artifact Reduction software should this be a requirement? 1.d 80cm calibrated FOV 2.k CT System will be plugged into back-up generator. UPS will be required to bridge an approximate 10 second gap till the generator power kicks in.

3.a. Requirement can change to 19” for full competition Additional question: Metal Artifact Reduction software desired - included in the Added Value section

AVISN 22644B08015The benchmark for this is the Siemens Luminos Agile Max, which is a conventional R/F room with the tube under the table. Please advise if the site will consider a remote R/F room with the tube above the table.
A remote R/F room would be great—it’s easier to use and allows for more functionality.
AVISN 22644B08017The benchmark quote contains a 65 kW generator and a 80 kW generator. Please clarify if the site wants/needs two generators or if this is specific to the benchmark vendor's configuration.
Please confirm no trade-insThe system only requires one generator. The benchmark quote included an upgrade from the minimum spec 65kW generator to an 80kW generator and put it as a separate line item. Note that per the benchmark, we prefer an 80kW generator. No trade-in. This is for a new outpatient clinic.
AVISN 22644B08016
644B08017This benchmark has listed both a 65kW and a 80kW generator. Can you please confirm whether the site wants a 65kW or 80kW generator?80kW generator
AVISN 22644B08016
644B08018On both Benchmark quotes, Line 8 lists 65 kW High Frequency Generator and Line 9 lists 80 kW High Frequency Generator, which do they want?80kW generator
AVISN 22644B08016
644B08018On both Benchmark quotes, Line 8 lists 65 kW High Frequency Generator and Line 9 lists 80 kW High Frequency Generator, which do they want?80kW generator