36A79720Q0010-011.pdf

PDF Posted

Attached to
6525--FEBRUARY 2020 CONSOLIDATION Federal contract opportunity
Solicitation number
36A79720Q0010
Issued by
Department of Veterans Affairs National Acquisition Center

About this file

36A79720Q0010 541B93021 - XR MAMMO, VAMC CLEVELAND, OH redacted.pdf

View the file

Other files for this federal contract opportunity

Other files attached to 6525--FEBRUARY 2020 CONSOLIDATION, newest first.
File Type Posted
36A79720Q0010-0002004.xlsx XLSX spreadsheet
36A79720Q0010-0002001.pdf PDF
36A79720Q0010-0002000.docx DOCX document
36A79720Q0010-0002003.zip ZIP file
36A79720Q0010-0002006.zip ZIP file
36A79720Q0010-0002005.zip ZIP file
36A79720Q0010-0002002.pdf PDF
36A79720Q0010-0001011.zip ZIP file
36A79720Q0010-0001004.zip ZIP file
36A79720Q0010-0001009.zip ZIP file
36A79720Q0010-0001010.zip ZIP file
36A79720Q0010-0001005.zip ZIP file
36A79720Q0010-0001003.zip ZIP file
36A79720Q0010-0001006.zip ZIP file
36A79720Q0010-0001001.pdf PDF
36A79720Q0010-0001008.zip ZIP file
36A79720Q0010-0001002.xlsx XLSX spreadsheet
36A79720Q0010-0001007.zip ZIP file
36A79720Q0010-0001000.docx DOCX document
36A79720Q0010-0001012.zip ZIP file
36A79720Q0010-017.zip ZIP file
36A79720Q0010-020.pdf PDF
36A79720Q0010-008.pdf PDF
36A79720Q0010-005.pdf PDF
36A79720Q0010-010.zip ZIP file
36A79720Q0010-007.xlsx XLSX spreadsheet
36A79720Q0010-022.pdf PDF
36A79720Q0010-019.pdf PDF
36A79720Q0010-016.zip ZIP file
36A79720Q0010-025.zip ZIP file
36A79720Q0010-015.zip ZIP file
36A79720Q0010-004.docx DOCX document
36A79720Q0010-006.pdf PDF
36A79720Q0010-024.zip ZIP file
36A79720Q0010-021.pdf PDF
36A79720Q0010-014.zip ZIP file
36A79720Q0010-023.zip ZIP file
36A79720Q0010-026.xlsx XLSX spreadsheet
36A79720Q0010-012.zip ZIP file
36A79720Q0010-029.pdf PDF
36A79720Q0010-028.pdf PDF
36A79720Q0010-013.zip ZIP file
36A79720Q0010-009.zip ZIP file
36A79720Q0010-027.pdf PDF
36A79720Q0010-018.zip ZIP file
Show all 45

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHIP TO ADDRESS

10701 EAST BLVD

CLEVELAND Ohio

United States 44106

3Dimensions with Affirm Upright Biopsy

Qty Product Name Description

1 3DM-SYS-STD 3DIMENSIONS

MAMMOGRAPHY

SYSTEM 3D US

1 PRD-04420 3DIMENSIONS

HIGH-

RESOLUTION

DETECTOR

1 3DM-KIT-

ERGO

3DM ERGONOMIC

UPGRADE

1 ASY-08109 I-VIEW CONTRAST

ENHANCED

2D IMAGING

SOFTWARE

LICENSE AND KIT

1 SDM-TRAIN-

INIT-06

CE2D TRAINING,

INITIAL, 1 DAY,

1 SITE, MAX 5

TECHS

REQUISITION: 541-B93021

REQUESTING SERVICE: RADIOLOGY-(W)

SHIP TO: WADE PARK WHSE

V.A. Medical Center

CHIEF, ACQ & MAT'L MGT

10701 EAST BOULEVARD

CLEVELAND, OH 44106

Qty Product Name Description

1 SDM-TRAIN-

ADDL-06

CE2D TRAINING,

ADDITIONAL, 1

DAY, 1 SITE, MAX

5 TECHS

1 SDM-LIC-0005 C-VIEW

SOFTWARE

LICENSE

1 3DM-LIC-I2D-

UP

INTELLIGENT 2D

IMAGING LICENSE

UPGRADE FROM

C-VIEW (3DM

ONLY)

1 STLC-00004 AFFIRM BREAST

BIOPSY

GUIDANCE

SYSTEM

1 ASY-06484 KIT, FMI,

DIMENSIONS

TOMO BIOPSY

1 SDM-TRAIN-

INIT-02

AFFIRM TRAINING,

INITIAL, 3 DAYS,

1 SITE, MAX 3

TECHS & 3 DOCS

1 BI-FURN-0002 AKRUS

STANDARD

MAMMOGRAPHY

CHAIR

1 SDM-TRAIN-

INIT-05

AFFIRM 3D UPG

TRAINING, INITIAL,

1 DAY, 1 SITE,

MAX 3 TECHS & 3

DOCS

1 ASY-09880 AFFIRM LATERAL

ARM UPRIGHT

BIOPSY

ACCESSORY KIT

1 SDM-TRAIN-

ADDL-05

AFFIRM 3D

TRAINING,

ADDITIONAL,

1 DAY, 1 SITE,

MAX 3 TECHS & 3

DOCS

1 SVC-SDM-

OPT-BTO

SELENIA

DIMENSIONS BTO

ENABLED

1 ASY-04662 RACK, PADDLE

STORAGE

1 R2-TRAIN-

INIT-01

CAD TRAINING,

INITIAL, 1 DAY,

1 SITE, MAX 10

RADS

1 R2LIC-2103-

V2.2

QUANTRA (2.2)

LICENSE FOR

ONE FFDM

1 R2SYS-2200 CENOVA 2D

TOWER SYSTEM

1 R2LIC-2111 IMAGECHECKER

CAD SOFTWARE

LICENSE FOR

ONE FFDM

Qty Product Name Description

1 R2-TRAIN-

ADDL-03

CAD TRAINING,

ADDITIONAL, 1

DAY, 1 SITE, MAX

10 RADS

1 DIM-TRAIN-

APPS-INIT

CLINICAL APPS

INITIAL TRAINING

1 DIM-TRAIN-

PHY-INIT

MEDICAL

PHYSICIST,

INITIAL TRAINING,

8 HOURS (5

HOURS LIVE - 3

HOURS ONLINE

TRAINING), 1

SITE, MAXIMUM 2

PHYSICISTS

1 DIM-TRAIN-

RAD-INIT

RADIOLOGISTS 3D

INITIAL TRAINING

8 HOURS VIRTUAL

TRAINING, 14

RADIOLOGISTS,

90 DAY ACCESS

PERIOD

Brevera Biopsy System

Qty Product Name Description

1 BREV100 BREVERA™

BREAST BIOPSY

SYSTEM WITH

CORLUMINA™

IMAGING

TECHNOLOGY

1 BREVDRV BREVERA®

BREAST BIOPSY

SYSTEM

REUSABLE

DRIVER

1 BREVADPTR BREVERA®

BREAST BIOPSY

SYSTEM

ADAPTER

1 BREVDRV BREVERA®

BREAST BIOPSY

SYSTEM

REUSABLE

DRIVER

3Dimensions with Affirm Upright Biopsy

Product Name Long Description

3DM-SYS-STD 3Dimensions™ mammography system for 3D™ screening and diagnostic mammography with 2D capabilities. Upgradeable to interventional imaging. 3Dimensions™ is a high-resolution capable system.

Includes: X-ray Gantry: •Generator: Fully integrated constant potential, high frequency, inverter type •X-ray Tube: Tungsten, bi-angular, high speed, high heat capacity •X-ray Filters: Rhodium, silver, aluminum •Anti-scatter Grid: Auto-retracting linear grid •Dual-function gantry footswitches (2) with Genius™ 3D Mammography™ artwork on gantry foot cover Adjustable-height Acquisition Workstation:

•CPU: Multi-Core Intel-based CPU, 16 GB RAM min., 2 TB disk min., DVD +/- R/W, Win 7/64 •NVIDIA GPU •User Interface Display: 1.2 MP color LCD touchscreen display •Image Review Display: 21.3” 3 MP, medical-grade color, DICOM monitor with double-jointed articulating arm •Full X-ray shield, X-ray exposure footswitch, pull-out keyboard drawer, keyboard and mouse •Uninterruptible Power Supply (UPS) 3Dimensions™ System Software: •User access control, patient and study selection, imaging procedure selection and definition, X-ray parameter control, image review and acceptance/rejection, quality control. •Software Licenses: 3Dimensions™ System, Diagnostic Imaging, Dynamic Tube Head Motion, Tomosynthesis Imaging, Advanced Connectivity, Bi-directional Communication (Notices), SmartCurve™ Breast Stabilization System Connectivity: •DICOM: Modality work list, storage, storage commitment, query/retrieve, print •IHE Profiles: Scheduled workflow, patient information reconciliation, mammography image •Advanced Connectivity: Ability for the system to participate in DICOM Modality Performed Procedure Step (MPPS) transactions and to output DICOM Radiation Dose Structured Report (RDSR) objects to third-party dose aggregation and reporting systems. The MPPS and RDSR capabilities can be enabled and disabled independently. Accessories: •Small 18 x 24 cm SmartCurve System and large 24 x 29 cm SmartCurve System •Screening Paddles (3): Frameless, 24 x 29 cm, 18 x 24 cm, small breast •Diagnostic Paddles (5): Spot contact, spot contact 10 cm, spot contact 7.5 cm, 10 cm magnification, 7.5 cm spot magnification •Spot Contact Paddle (1): 7.5 cm for use during QC testing only •Other: Magnification stand with platform, flat field phantom and case, ACR tomosynthesis geometry calibration phantom, Dimensions interconnect cable kit •Shields: 2D fixed face shield and sliding 3DMammography™ face shield •MammoPad® Breast Cushion trial box Platinum Marketplace: The Hologic® Platinum Marketplace provides access to free and for purchase promotional and educational material designed to help drive demand for the Hologic products that your site offers. From customizable features to options for digital download or professional printing, choose what works best for your practice.

Added value: $5000. Included Service: Installation by Hologic certified technicians. Warranty: Standard one-year parts and labor warranty; two-year prorated manufacturer's warranty on X-ray tube. Warranty service coverage is Monday-Friday from 8:00 am to 5:00 pm local time. Conditions: •Required but independently sold software features are not included gratis under Hologic Warranty, or Hologic Service Contracts that include software upgrades, and must be ordered separately •Required system software updates that are included under Hologic Warranty, or Hologic Service Contracts will be provided at no charge SecurView® Workstation Recommendations: If using SecurView workstations, please contact your Hologic representative to confirm that your workstations meet the minimum software and hardware requirements to support the 3Dimensions™ configuration.

PRD-04420 Hologic 3D Mammography™ high-resolution digital image receptor for 3Dimensions™ mammography systems or to upgrade existing Selenia® Dimensions® systems. Includes: Digital Image Receptor •Amorphous selenium, TFT •Structure: Single 24 x 29 cm plate •Image Matrix Sizes: 2560 x 3328 (18 x 24 cm); 3328 x 4096 (24 x 29 cm) •Pixel Size: 0.070 mm •Limiting Spatial Resolution: 7.1 lp/mm

3DM-KIT-ERGO Provides an integrated ergonomic package for the 3Dimensions™ system. Includes: •Fingerprint reader for quick biometric login of the technologist, manager or other site personnel •Powered memory height adjust •Bar code scanner Note: •Kit only available for 3Dimensions systems

ASY-08109 The I-View option provides contrast enhanced 2D (CE2D) imaging for one (1) Selenia® Dimensions® 2D or 3D™ system, or one (1) 3Dimensions™ system. This option allows CE2D imaging on both 2D and 3D™ systems, and CE2D Combo imaging on 3D™ systems. Includes: •CE2D Software License •Copper filter Included Training: •Two days training at one site, maximum 5 technologists. Requirements:

•Dimensions system software version 1.8.3 or later •Dimensions system with Diagnostic license installed •Supply the Dimensions system serial number with your order Recommended: •3MP medical grade DICOM monitor

Quote #: Q-121541-1

SDM-TRAIN-INIT-06 This two-day technologist instructional training is provided by a Hologic Clinical Applications Specialist and includes both didactic instruction and hands-on clinical patient examinations. The added value for the training is $3,800.00 and is included in the price of the I-View™ software license. Application training on I-View software for Contrast Enhanced 2D Mammography is conducted on 2 consecutive days, with clinical patients scheduled starting the afternoon of the 1st day and continuing on through the 2nd day.

Technologists must be available the entire training. Please refer to the I-View software Contrast Enhanced 2D Mammography Preparation Guide and Agenda for Applications Training for additional information.

Hologic recommends that Radiologists attend the course "Contrast-enhanced Mammography" available from www.ICPME.us Price for above is "included in the price" of I-View.

SDM-TRAIN-ADDL-06 This purchase entitles additional consecutive two-day technologist instructional training provided by a Hologic Clinical Applications Specialist on I-View™ software for Contrast Enhanced 2D Mammography.

Application training on I-View software for Contrast Enhanced 2D Mammography is conducted on 2 consecutive days, with clinical patients scheduled starting the afternoon of the 1st day and continuing on through the 2nd day. Technologists must be available the entire training. Price for above is $3,800.00.

Extra two days of contrast enhanced training 1 site, maximum of 5 technologists.

SDM-LIC-0005 Enables creation of C-View™ generated 2D images on Selenia® Dimensions® systems or 3Dimensions™ systems configured with Hologic standard resolution 3D™ imaging. The C-View software license adds the ability to create low dose tomosynthesis studies in Tomo HD (standard tomo + C-View) and Combo HD (standard tomo + FFDM + C-View) imaging modes. Includes: •C-View Generated 2D Imaging software license

3DM-LIC-I2D-UP Enables creation of Intelligent 2D™ images on 3Dimensions™ systems configured with Clarity HD high-resolution 3D™ imaging. The Intelligent 2D Imaging software license adds the ability to create low-dose tomosynthesis studies in Tomo HD (high-resolution tomo + Intelligent 2D) and Combo HD (high-resolution tomo + FFDM + Intelligent 2D) imaging modes. Intelligent 2D may be used to replace FFDM when used in combination with high-resolution 3D™ imaging. Includes: •Intelligent 2D™ Imaging software license Requirements: •3Dimensions™ or Selenia Dimensions system with software version 1.9 or later •Clarity HD High-resolution 3D™ Imaging license •Supply Selenia Dimensions system serial number at time of purchase •Advanced Workflow Manager software version 1.8.2 or later Note for optional CAD application:

•Cenova™ software version 3.0 or later •ImageChecker ® CAD software version 10.0 or later •Service flag needed to enable CAD for Intelligent 2D processing at this facility Intelligent 2D™ upgrade (part #: 3DM- LIC-I2D-UP) includes license, 12 months of software maintenance, and one-time installation. Installation is for a one-time setup of Intelligent 2D from C-View™. If customer no longer requires the use of Intelligent 2D and would like to go back and configure the system for C-View later, the customer will incur a separate service charge. Part number is only valid for a 3Dimensions™ and not a 3D™ Performance, 6000 or 9000 Selenia® Dimensions® system.

STLC-00004 The Affirm® upright breast biopsy guidance system for a 3Dimensions™ system or Selenia® Dimensions® system supports stereotactic 2D biopsy and wire localization. Supports fast positioning through motorized X and Y axis guidance with manual Z direction positioning. The Affirm upright does more than deliver superior imaging performance to 2D biopsy. It’s designed to integrate with the Selenia Dimensions system from the ground up to streamline workflow and accelerate the journey from screening to breast biopsy. Includes: •Affirm breast biopsy guidance module •Biopsy control module with touchscreen display •One (1) Stereotactic 2D Biopsy software license for one gantry; additional licenses may be purchased •Biopsy compression paddles (3): Standard biopsy compression paddle (biopsy window: 5.4 x 5.2 cm); axillary biopsy compression paddle (biopsy window: 5.4 x 5.2 cm); wide biopsy compression paddle (biopsy window: 7.4 x 6.2 cm) •Quality assurance needle •Needle guide holder •Geometry calibration phantom •Affirm tabletop stand •User and service manuals Included Training:

•Three days onsite training for 3 technologists and 3 radiologists Requires: •2MP medical grade LCD display •Dimensions system software version 1.9 or later •3Dimensions™ or Selenia Dimensions system with both diagnostic and dynamic tube head motion for 2D Biopsy license installed •3Dimensions™ or Selenia Dimensions system serial number at time of order Recommendations: •3MP medical grade DICOM monitor Hologic® Platinum Marketplace: Access to a comprehensive co-operative marketing program focused on business growth through patient and referring physician education on the benefits of the Affirm™ breast biopsy guidance system. Online entry into the program will be provided once order is placed and online initiation form completed at hologicmarketplace.com/user/register.

ASY-06484 The Affirm® Tomosynthesis Biopsy Option software license provides the ability to easily and accurately target lesions with tomosynthesis imaging including lesions that may only be found under tomosynthesis. This license provides the ability to use Affirm tomosynthesis biopsy option software on one (1) 3Dimensions™ or Selenia® Dimensions® tomosynthesis system that has an Affirm Upright Biopsy license. Also included is a tomosynthesis biopsy QAS needle. Intended for use on installed 3Dimensions™ or Selenia Dimensions systems. Includes: •3D™ Biopsy license •3D™ QAS Target Requires: •3Dimensions 3D™ or Selenia Dimensions system with software version 1.9 or later •Tomosynthesis license •Affirm breast biopsy guidance system •Affirm Biopsy license •Supply the system serial number with your order Recommendation: •3MP medical grade DICOM monitor •Two (2) dual-function gantry footswitches

SDM-TRAIN-INIT-02 Three (3) days of Applications Training for 3 technologists and 3 doctors per site. * Applications must be completed within 24 months of equipment installed. * Please note: Cancellation must be made 6 business days prior to the confirmed and scheduled applications training start date. Fee for Cancellation $2,000.00 Initial Applications Added Value: $5,100.00

BI-FURN-0002 AKRUS mammography positioning and biopsy chair. Supports seated, decubitus and Trendelenburg positioning. Includes: • Adjustable backrest (0 to 90 degrees) • Adjustable backrest segments • Adjustable arm supports • Adjustable headrest • Lateral back support • Electronic lift • Three position braking system • Max pt weight 330 lb Warranty: • Standard one-year parts and labor warranty

SDM-TRAIN-INIT-05 * One (1) day of applications Training for up to 3 Technologists and 3 Doctors per site. * Applications must be completed within 24 months of equipment install. * Please note: Cancellation must be made 6 business days prior to the confirmed and scheduled applications training start date. Fee for Cancellation $2,000.00 Initial Applications Added Value: $2,500.00

ASY-09880 Provides secure mounting of biopsy hand pieces onto the Affirm® breast biopsy guidance system. The Affirm lateral arm upright biopsy accessory is an optional accessory to the Affirm biopsy guidance system and has the capability to perform 2D or tomosynthesis-guided biopsies using a right or left lateral needle approach. Includes: •Lateral arm hardware •Lateral arm stand enables technicians to elevate the breast off the detector – to maximize access and minimize the potential for needle-to-platform collision •15 cm lateral biopsy paddle •Lateral QAS phantom •License key and software for the lateral arm upright biopsy accessory •User and service manuals Requires: •Affirm breast biopsy guidance system •Dimensions® software version 1.8.3 or later •Supply the Dimensions and Affirm breast biopsy guidance system serial numbers at time of order - last four digits of Affirm serial number must be greater than or equal to: 0913 Access to a comprehensive co-operative marketing program focused on business growth through patient and referring physician education on the benefits of the Affirm™ breast biopsy guidance system. Online entry into the program will be provided once order is placed and online initiation form completed at hologicmarketplace.com/user/register. Estimated value included per system: $5,000.00

SDM-TRAIN-ADDL-05 * One (1) day of applications Training for up to 3 Technologists and 3 Doctors per site. * Applications must be completed within 24 months from date of purchase. * Please note: Cancellation must be made 6 business days prior to the confirmed and scheduled applications training start date. Fee for Cancellation $2,000.00

SVC-SDM-OPT-BTO This configuration enables output of tomosynthesis slices in DICOM Breast Tomosynthesis Image Object form. Use of this configuration will first require an integrated planning team, including your IT department, Hologic and other vendors, to work together to ensure that your enterprise is ready for use of the tomosynthesis data in DICOM Breast Tomosynthesis Image Object form. The completion of critical feasibility questions included in Hologic’s Enterprise Survey will guide the team through understanding any infrastructure requirements and changes necessary. Note: While a preliminary check by your Hologic representatives may have allowed the ability to quote this output configuration, completion of the Enterprise Survey is required before Dimensions Tomosynthesis system or option is enabled.

Software and hardware upgrades may be required. Hologic makes no guarantees of software and hardware performance for products not associated to Hologic. By signing this quote, the customer agrees that the completion of purchase of the accompanying Hologic products shall not be contingent on the implementation of this no-charge configuration. Requires: - Completion of Hologic Enterprise Survey by site personnel in conjunction with Hologic representatives - PACS system including Deep Archive capable of storing / retrieving DICOM Breast Tomosynthesis Image Objects and with suitable storage capacity - Softcopy review workstation capable of displaying DICOM Breast Tomosynthesis Image Objects

ASY-04662 Wall-mounted, felt-lined rack for storing system compression paddles. Each rack, sold separately, provides enough storage room for 3-4 compression paddles. Includes: •Paddle storage rack with felt lining •Wall-mounting bracket (installation not included) •Graphic paddle labels Dimensions: •W x H x D: 36 1/4" x 7" x 4" (from the wall) •Minimum Vertical Pitch: 12" to 14” when multiple racks are installed one above another Recommended: •Selenia® Dimension® Avia systems: min. 1 rack •Selenia Dimensions 2D systems: min. 2 racks •Selenia Dimensions 3D™ systems: min. 3 racks •3Dimensions™ systems: min. 3 racks Requirements: •Must be securely attached to the wall •Must be installed by a professional installer

R2-TRAIN-INIT-01 * One (1) day of Applications Training. Training for up to 10 Rads * Applications must be completed within 24 months of equipment installed. * This training cannot be performed until FFDM certification extension is received for Tomosynthesis. * Please note: Cancellation must be made 6 business days prior to the confirmed and scheduled applications training start date. * Fee for cancellation $2,000.00 * Initial Application Added Value: $2,500.00

R2LIC-2103-V2.2 Quantra™ breast density assessment software to standardize breast density analysis for 2D and 3D mammography images on the 3Dimensions™ or Dimensions® system. The Quantra software license adds one Quantra port license to a Cenova™ server for a single mammography system. Quantra calculates breast density using machine learning algorithms that evaluate pattern and texture of dense breast tissue. Quantra segregates breast density into BI-RADS®-like categories based on the BI-RADS Atlas 5th Edition. The results may be useful in the reporting of consistent BI-RADS breast composition categories as mandated by certain state regulations. The Quantra results for each breast and subject are intended to aid radiologists in the assessment of breast tissue composition. Quantra produces adjunctive information; it is not an interpretive or diagnostic aid. The output may be transmitted to viewing stations via a DICOM Structured Report or DICOM Secondary Capture image. Includes: •Quantra Breast Density license version for one Hologic system

R2SYS-2200 The Cenova™ digital mammography processing system hosts image analytics software applications.

Image analytics licenses are sold separately. Includes: •Cenova processing unit server (6U) •Windows 7 operating system •Dynamic resource management and case control •Output transmission re-try mechanism •Flexible output routing to multiple output destinations •License dongle •Hologic Connect™ remote system diagnostics software for post-installation service and applications support; conforms with Verisign security Requirements: •Specify manufacturer and model of FFDM system at time of order •Verify with the technical team that the number of licenses on a server can be adequately supported. Notes:

•This server can be used horizontally and rack-mounted by ordering R2ACC-2001. (R2SYS-2200-1U is a thinner server, ships with a rack mount and is preferred for rack mounting.) •The system is designed to process 2D images only

R2LIC-2111 The ImageChecker® Digital computer-added detection (CAD) and Citra™ advanced CAD display software adds one port license to a Cenova™ image analytics server to process images from a single digital mammography system. Includes: •One ImageChecker CAD software license to support: •Hologic software generated 2D For Processing synthesized images •Hologic and other manufacturers’ For processing 2D FFDM images •Citra advanced CAD display license to provide additional information about why ImageChecker CAD marked specific regions: •RightOn™ CAD marks placed right on the potential region-of-interest to unambiguously flag the location •Malc™ CAD marks placed where the algorithm detects signs of both density and calcifications •PeerView Digital to outline exactly the tissue that caused CAD to mark the region •EmphaSize™ variable size CAD marks differentiate CAD marks that have more prominent features •LesionMetrics™ ancillary CAD information to display additional quantitative information about the finding Requirements: •A Cenova server at Cenova software version

2.4.3 or later •Specify serial number, manufacturer and model of FFDM system at time of order •For CAD on synthesized 2D images, a Dimensions® tomosynthesis system with software version 1.8.3 or higher •Please refer to SecurView® DX diagnostic workstation description for minimum requirements Notes:

•Advanced Citra CAD features require workstations that conform to proper display of those features.

They can be disabled for use with other non-conformant workstations. The customer needs to check with their workstation vendor •This item is for use with 2D Images only. •Verify with the technical team that the number of licenses on a server can be adequately supported. •Order additional licenses for each additional FFDM system. •With respect to the future development path of our products, during the warranty period and during the term of any Hologic Service Agreement, Hologic will provide, at no cost to the Customer, any commercially released software update that (i) improves the ability of any Equipment purchased under the Agreement

R2-TRAIN-ADDL-03 One (1) additional, purchasable, day of applications training for up to 10 Radiologists. Applications must be completed within 12 months of equipment shipment. This training cannot be performed until FFDM certification extension is received for Tomosynthesis. Note: Cancellation must be made 6 business days prior to the confirmed and scheduled applications training start date. Fee for cancellation within 6 business days of confirmed training is $2,000.

DIM-TRAIN-APPS-INIT Included in the purchase price of your 3Dimensions™ or Selenia® Dimensions® system(s); Initial applications added value of $5,100. Technologists: Onsite applications training or other clinical support at one site, maximum of 5 technologists. •Online CEU courses required prior to onsite applications training •Video training available during and post applications training •Onsite portion of purchased applications training or other clinical support must be completed within 24 months of equipment installation. Required FDA training: •FFDM accreditation is required: Apply to the ACR or your State for FFDM certification.

•Once FFDM accredited, contact the MQSA FFDM Certification Extension Program for Tomosynthesis at 301-796-5710. •Sites must obtain ACR or State FFDM accreditation before using the tomosynthesis modality Note: Cancellation must be made 6 business days prior to the confirmed and scheduled applications training start date. Fee for cancellation within 6 business days of confirmed training is $2,000.

DIM-TRAIN-PHY-INIT Included in the purchase price of your 3Dimensions™ or Selenia® Dimensions® system(s); Initial applications added value of $1,500. Medical Physicists: 5 hours of live tomosynthesis training with a Hologic Field Service Engineer during the installation of the system and access to Hologic’s 3-hour online tomosynthesis training course for medical physicists to fulfill the 8 hour FDA requirement. See course description for more details and requirements. Visit www.hologic.com/training for a complete list of Hologic educational opportunities. Note: Cancellation must be made 6 business days prior to the confirmed and scheduled applications training start date. Fee for cancellation within 6 business days of confirmed training is $2,000.

DIM-TRAIN-RAD-INIT Included in the purchase price of your 3Dimensions™ or Selenia® Dimensions® system(s); Initial applications added value of $5,250. Radiologists: Access to Hologic's virtual tomosynthesis training course for up to 14 radiologists. This program will fulfill the 8-hour FDA training requirement. Upon activation, each radiologist will have 90 days to complete the course. See course description for more details and requirements. Visit www.hologic.com/training www.hologic.com/training for a complete list of Hologic educational opportunities.

Brevera Biopsy System

Product Name Long Description

BREV100 The Brevera breast biopsy system with CorLumina imaging technology has system components for vacuum-assisted breast tissue biopsy and system components for x-ray generation and image acquisition under stereotactic X-ray or tomosynthesis image guidance. A user interface for data entry, patient selection, and image acquisition and review is on the Imaging display. Console requires an adapter for each image guidance system and includes: Two days on-site training-One year standard parts and labor warranty-Title passes to customer. Hologic® Platinum Marketplace: Access to a comprehensive co-operative marketing program focused on business growth through patient and referring physician education on the benefits of the Affirm™ prone breast biopsy guidance system.

Online entry into the program will be provided once order is placed and online initiation form completed at hologicmarketplace.com/user/register. Estimated value included per system: $5,000.00

BREVDRV The biopsy device driver is an electromechanical component powered by the console. When the device driver is connected to the biopsy needle, the device driver propels the rotation and the advancement of the cutting cannula in the biopsy needle. The device driver also arms and fires the biopsy needle.

BREVADPTR The Brevera adapter is a separately packaged accessory that connects the Brevera biopsy device to the Hologic prone or upright image guidance system.

File details come from the government source that posted it. Updated .