32098_Jan_28_26_solicitation_doc.pdf
PDF 17 KB Posted
- Attached to
- ODOR CONTROL IMPROVEMENTS
- Solicitation number
- 32098
- Issued by
- Connecticut
About this file
Odor Control Improvements - Solicitation Document
This is a solicitation document issued by the Connecticut Department of Energy and Environmental Protection (DEEP) for odor control improvements at the Water Pollution Control Facility. The project encompasses the installation of new carbon filtration equipment, demolition of the existing biofilter and aluminum grating from the primary clarifier effluent channel, installation of a stationary anti-rotation scum deflector on the secondary clarifiers, and covering of the anoxic tanks. The solicitation document outlines the technical specifications, project scope, and bidding requirements for contractors interested in undertaking these facility upgrades designed to improve operational efficiency and environmental performance.
The document establishes the bidding timeline, evaluation criteria, and contractual terms governing contractor selection and project execution. Key provisions address insurance requirements, bonding, compliance with Connecticut regulations, and safety standards applicable to work at the Water Pollution Control Facility. The solicitation specifies documentation requirements for bidders, including proof of licensing, financial capacity, and relevant project experience. Award decisions will be based on qualifications, pricing, and technical merit, with the selected contractor expected to complete the work according to the specified schedule and technical requirements outlined in the project plans and specifications.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation Number: 32098
ODOR CONTROL IMPROVEMENTS
Invitation to Bid (ITB)
South Windsor, Town of
August 26, 2025 - September 30, 2025
Page:2
General Header Information
32098
No. 32098 Title: ODOR CONTROL IMPROVEMENTS Start Date: August 26, 2025 at 10:00:00 AM EDT End Date: September 30, 2025 at 11:00:00 AM EDT Vendor Q&A Start Date:
Vendor Q&A End Date:
Estimated Total Value:
Who can respond to this bid? : All Vendors Description: Installation of new carbon filtration equipment, the demolition of the existing biofilter and aluminum grating from the primary clarifier effluent channel, the installation of a stationary anti rotation scum deflector on the secondary clarifiers, and the covering of the anoxic tanks at the Water Pollution Control Facility.
Delivery Terms: Free On Board Destination Payment Terms: Vendor Specified Contact Information: South Windsor, Town of
Anthony Manfre 1540 Sullivan Avenue South Windsor CT, 06074 United States Tel: 860-644-2511 Fax:
Anthony.manfre@southwindsor-ct.gov
Contact Details: If you have any questions, please contact:
Anthony Manfre 1540 Sullivan Avenue South Windsor CT, 06074 United States Tel: 860-644-2511 Fax:
Anthony.manfre@southwindsor-ct.gov
Selected Categories:
Page:3
Header Custom Fields:
32098
Invitation to Bid
N/A
Page:4
Solicitation Requirements:
This bid has no questions defined.
32098
Invitation to Bid
Page:5
Documents:
Odor Control Invitation to Bid_Signed.pdf
Page:6
Item Specifications
No. Item Alternative Supplier Part No Mfr.
Name
Mfr. No Del
Date
Unit Unit Bid Qty. Total
1 ODOR CONTROL each 1.00
Item Specification for ODOR CONTROL
Description: Installation of new carbon filtration equipment, the demolition of the existing biofilter and aluminum grating from the primary clarifier effluent channel, the installation of a stationary anti rotation scum deflector on the secondary clarifiers, and the covering of the anoxic tanks at the Water Pollution Control Facility
Allow Vendor to Enter Negative Value : No
Exclude Line Item from Bid Total : No
2 CARBON FILTRATION each 1.00
Item Specification for CARBON FILTRATION
Description: Installation of new carbon filtration equipment, the demolition of the existing biofilter and aluminum grating from the primary clarifier effluent channel, the installation of a stationary anti rotation scum deflector on the secondary clarifiers, and the covering of the anoxic tanks at the Water Pollution Control Facility
Allow Vendor to Enter Negative Value : No
Exclude Line Item from Bid Total : No
Page:7
File details come from the government source that posted it. Updated .