314_Flagpatch_Rd_Lead_Report[1].pdf
PDF 4 MB Posted
- Solicitation number
- 2023-04-007
- Issued by
- Horry County, Lugoff CDP, South Carolina
About this file
This document is a Lead-Based Paint Inspection Report prepared by Asbestos Inspections, LLC for Horry County Government, conducted on a single-family home located at 314 Flagpatch Road in Loris, South Carolina. The inspection was performed on June 8, 2023, with the report prepared on June 15, 2023, in accordance with HUD guidelines and OSHA regulation 29 CFR 1926.62. The purpose of the inspection was to identify lead-based paint on building components prior to the scheduled demolition of the property, which is a 1,092 square feet single-family home with a pitched shingle roof, brick veneer siding, and wood windows.
The laboratory analysis of paint chip samples revealed lead concentrations in white wood windowsills throughout the home, with one sample (P2) showing a lead concentration of 0.56 mg/cm², which exceeds the HUD standard of 1.0 mg/cm² or 0.5% by weight for lead-based paint. The inspection involved collecting eight paint chip samples from various surfaces, including exterior and interior components such as doors, windowsills, walls, and trim. The samples were analyzed by Eurofins/CEI using EPA Method SW846 7000B, and the results indicate that while most samples were below the lead threshold, the windowsills pose a potential lead-based paint hazard. The report emphasizes the importance of proper handling and disclosure of lead-based paint findings to future owners, tenants, and contractors.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Required Bid Forms Packet.pdf | ||
| IFB# 2023-24-007 314 Flag Patch Road.pdf | ||
| 314 Flag Patch Pre Bid Sign in.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEAD-BASED PAINT INSPECTION REPORT
314 Flagpatch Road
Loris, South Carolina Asbestos Inspections, LLC Project # 2023-03-205
Performed in general accordance with HUD along with OSHA regulation 29 CFR 1926.62
Assessment Completed by:
Asbestos Inspections, LLC 4686 Pee Dee Highway
Conway, South Carolina 29527
(843) 995-5197
Dawn Schoolcraft
Lead Paint Inspector #LBP-R-I162035-2
Assessment Completed For:
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue
Conway, South Carolina 29526
Inspection Completed On – June 8, 2023 Report Prepared On – June 15, 2023
Lead-Based Paint Inspection Report
Project Number – 2023-03-205 June 15, 2023
TABLE OF CONTENTS
Appendix 1-Site Locations Plan and Sample Location Plan Appendix 2-Photographs Appendix 3-Lead-Based Paint Laboratory Results Appendix 4-License
1.0 SIGNATURE PAGE
This report has been performed at the request of Mr. Sam LoFaso with Horry County Government. The inspection was conducted by Mike Schoolcraft with Asbestos Inspections, LLC on June 08, 2023. The report was prepared and reviewed by the undersigned inspector.
Inspection Performed by: License# Signature Date
Mike Schoolcraft LBP- I-I241150-1 Mike Schoolcraft June 08, 2023
Report Prepared by:
Dawn Schoolcraft LBP-R-I162035-2 Dawn Schoolcraft June 15, 2023
Report Reviewed by:
Dawn Schoolcraft LBP-R-I162035-2 Dawn Schoolcraft June 15, 2023
2.0 COVER LETTER
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue Conway, South Carolina29526
Subject: Lead-Based Paint Inspection Report 314 Flagpatch Road Loris, South Carolina Asbestos Inspections, LLC Project # 2023-03-205
Asbestos Inspections, LLC has completed a Lead-Based Paint Inspection for the structure located at 314 Flagpatch Road, in Loris, South Carolina. The inspection was completed on June 08, 2023 by a licensed lead paint inspector.
The following report summarizes the project background, assessment procedures, results, and conclusions. The results presented in this report are indicative of conditions during the time of the inspection and of the specific areas outlined. The information provided in this report should not be used as a bidding document and field conditions should be verified. Should suspect paint coated surfaces, not included within this report, be identified or impacted during the destructive activities, samples must be collected and analyzed for lead content.
Disclosure Responsibility: A copy of this summary must be provided to new lessees (tenants), owners and purchasers of this property under Federal Law (24 CFR part 35 and 40 CFR part 745) before they become obligated under a lease or sales contract. The complete report must also be provided to new purchasers and it must be made available to new tenants. Landlords (lessors) and sellers are also required to distribute an educational pamphlet and include standard warning language in their leases or sales contracts to ensure that parents have the information they need to protect their children from lead-based paint hazards.
I appreciate this opportunity to provide my services. Should you have any questions concerning this report, please contact me at (843) 995-5197.
Sincerely, Lead Paint Inspector (License #LBP-R-I162035-2)
3.0 PROJECT INFORMATION
1.1 Scope and Purpose
Mr. Sam LoFaso with Horry County Government requested this inspection for the structure located at 314 Flagpatch Road in Loris, South Carolina. Based on information obtained from you, the structure is scheduled for demolition. The purpose of this assessment was to identify lead-based paint on building components prior to the scheduled demolition.
The inspection was completed in accordance with procedures specified in the Department of Housing and Urban Development (HUD) 1997 Revision that replaces Chapter 7, Lead-Based Paint Inspection along with Occupational Safety and Health Administration (OSHA) Lead in Construction Standard regulation 29 Code of the Federal Regulations (CFR) 1926.62. The representative bulk samples collected were analyzed by a laboratory recognized under the Environmental Protection Agencies (EPA) National Lead Laboratory Accreditation Program (NLLAP).
2.1 Facility Conditions
The subject structure is a 1,092 square feet single-family home with a pitched shingle roof, brick veneer siding, and wood windows. The interior consists of mostly wood panelled walls, drywall ceilings, and flooring ranging between wood, carpet and sheet flooring.
The possibility exists that paint coated surfaces were undetected in inaccessible areas such as, locked rooms, behind exterior veneer, pipe chases, or wall voids. If additional suspect paint coated surfaces not included in this report are discovered during renovation, samples should be collected and analyzed for lead content.
3.1 Lead-Based Paint Assessment Data
The assessment was performed by identifying paint coated surfaces associated with the structure in accordance with HUD guidelines. One paint chip sample was collected for each painted surface of the structure’s building components, which includes but is not limited to shutters, siding, exterior trim, window trim, windowsills, interior and exterior doors, door frames, walls, baseboards, chair rails and floors. The samples collected were approximately 1-4 square inches in size and included all layers of paint, placed inside an appropriate sample container, and labeled accordingly using a unique identification number. A chain of custody was completed for the samples with project specific information and then submitted to Eurofins/CEI for analysis. The samples collected were analyzed via EPA Method SW846 3050B/7000B. The following outlines the paint chip samples collected and analyzed:
Sample # Substrate Component Color Paint Location Condition Lead Concentration (mg/cm2 ) P1 Wood Exterior Door White Back Porch Intact 0.098 P2 Wood Windowsill White Bedroom 2 Intact 0.56 P3 Wood Handicap Ramp Red Handicap Ramp Intact <0.0049
Sample # Substrate Component Color Paint Location Condition Lead Concentration (mg/cm2 ) P4 Wood Windowsill Tan Living Room Intact <0.011 P5 Wood Interior Door Tan Hallway Intact <0.013 P6 Drywall Interior Wall White Bathroom Intact 0.0042 P7 Wood Interior Window White Bathroom Intact <0.0080 P8 Metal Exterior Door White Kitchen Intact <0.0078
Condition Assessment Key
Type of Bldg. Component Total Area of Deteriorated Paint on Each Component
Intact Fair1 Poor2
Exterior components with large surface area
Entire surface area is intact
Less than or equal to 10 square feet
More than 10 square feet
Interior components with large surface area
Entire surface area is intact
Less than or equal to 2 square feet
More than 2 square feet
Interior and exterior components with small surface areas
Entire surface area is intact
Less than or equal to 10% of the total surface area of component
More than 10% of the total surface area or the component
Superscript 1 = surfaces in “fair” condition should be repaired and/or monitored but are not considered to be lead based paint hazards.
Superscript 2 = surfaces in “poor” condition are considered to be lead based paint hazards as defined by Title X and should be addressed through abatement or interim controls.
Site location plan and sample locations are identified as Figures 1 and 2 in Appendix 1 of this report, photographs are in Appendix 2, lead-based paint lab results are in Appendix 3, and licenses are in Appendix 4.
4.1 Conclusions
HUD defines paint as lead-based if an amount greater than 1.0 mg/cm2 or 0.5 percent by weight is identified in a paint chip sample. The results of this inspection indicate that lead in concentrations greater than or equal to 1.0 mg/cm2 or 0.5 percent by weight was identified on the building components sampled and analyzed for the structure located at 314 Flagpatch Road, in Loris, South Carolina:
White Wood Windowsills throughout the home
A copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations. Additionally, this report should be kept by the owner and future owners for the life of the dwelling.
Site Location Plan and Sample Location Plan
Site Location Plan 314 Flagpatch Rd Loris, SC Project # - 2023-03-205
Scale: Not to Scale Reviewed By: DS Date: 6/9/23 Source: N/A
Figure 1
Subject Property
Sample Location Plan 314 Flagpatch Rd Loris, SC Project # - 2023-03-205
Figure 2
LEGEND
Sample Location
Scale: Not to Scale Reviewed By: DS Date: 6/9/23 Source: N/A
Figure 2
LEGEND
Sample Location
Kitchen
P1
P7
Bath Bedroom 3
Bedroom 2Bedroom 1
Living Room
P6
P2
P5
P3
P8
P4
Photographs
Site Photos
Exterior
Bedroom
Bathroom
Living Room
Living Room
Kitchen
Laboratory Results
Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
06-12-23 06-14-23Analyzed:
LABORATORY REPORT
LEAD IN PAINT
Lab Code: C230779
LAB ID
Received:
CLIENT ID
314 Flagpatch RdProject:
Client:
PPM (µg/g) CONCENTRATION
% BY WEIGHT
Eurofins CEI 730 SE Maynard Road Cary, NC 27511
TEL: 866-481-1412
TEL: 919-481-1413
FAX: 919-481-1442
METHOD: EPA SW846 7000B
06-14-23Reported:
P1 CA3055 0.098980
P2 CA3056 0.565600
P3 CA3057 <0.0049<49
P4 CA3058 <0.011<110
Sample weight below protocol guidelines
P5 CA3059 <0.013<130
Sample weight below protocol guidelines
P6 CA3060 0.004242
P7 CA3061 <0.0080<80
P8 CA3062 <0.0078<78
Page 1730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
METHOD: EPA SW846 7000B
LAB ID
Eurofins CEI 730 SE Maynard Road Cary, NC 27511
TEL: 866-481-1412
TEL: 919-481-1413
FAX: 919-481-1442
Project: 314 Flagpatch Rd
Lab Code: C230779
CLIENT ID PPM (µg/g)
CONCENTRATION
% BY WEIGHT
LEGEND µg = microgram ml = milliliter ppm = parts per million Pb = lead g = grams
Reviewed By:
This method has been validated for sample weights of 0.020g or greater. When samples with a weight of less than that are analyzed those results fall outside of the scope of accreditations.
* The analysis of composite wipe samples as a single samples is not included under AIHA accreditation.
Minimum reporting limit is 10 µg total lead. Sample results denoted with a “less than” (<) sign contain less than 10.0 µg total lead, based on a 40ml sample volume.
REGULATORY
LIMITS
Federal Lead Standard / HUD: 0.5% lead by weight.
wt = weight
Consumer Products Safety Standard: Greater than 0.009% lead by weight.
OSHA Standard: No safe limit.
Lead samples are not analyzed by Eurofins CEI Lead samples are submitted to an AIHA ELLAP accredited laboratory for lead analysis of soil, dust, paint, and TCLP samples.
Laboratory results represent the analysis of samples as submitted by the client. Information regarding sample location, description, area, volume, etc., was provided by the client. Unless notified in writing to return samples, Eurofins CEI discards client samples after 30 days. This report shall not be reproduced, except in full, without the written consent of Eurofins CEI.
Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.
Tianbao Bai, Ph.D.
Laboratory Director
End of Report
Page 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Certifications
12884, 06/30/2023, North Carolina, Dawn Schoolcraft
1909008, 09/30/2023, South Carolina, Dawn
LBP-R-I162035-2, 03/16/2024, South Carolina, Dawn Schoolcraft
BI-00738, 06/06/2023, South Carolina, Dawn