This file consists of three preliminary site plans for the GRIC District 4 Subdivision Sites 1 and 6 feasibility master plan located in Queen Creek, Arizona. The document presents detailed lot layouts and specifications for two distinct development sites prepared by MergeAG, a Phoenix-based architectural and planning firm. Site 1 features 30 residential lots ranging from 0.50 to 0.54 acres each, with two stormwater retention basins totaling approximately 70,140 square feet. Site 6 contains 30 residential lots of 0.50 acres each, with two stormwater retention basins totaling approximately 81,324 square feet. Both sites are bounded by Street A, Street B, Street C, and Sotonic Road, with standard setback requirements of 35 feet for front yards with sidewalks, 25 feet for sides facing streets, 15 feet for rear yards, and 10 feet for in-between lot setbacks. The plans are dated January 21, 2026, and include comprehensive drainage, utility, landscaping, and accessibility requirements coordinated across multiple discipline drawings.

The site plans incorporate mandatory construction specifications including positive drainage slopes of 1 percent minimum to 2 percent maximum for pedestrian areas, finish grade slopes not exceeding 1 foot vertical in 3 feet horizontal, fiber-reinforced concrete sidewalks with control joints at 5-foot intervals and expansion joints at 25-foot intervals, and underground utility placement. All lighting is restricted to one foot candle at property lines and must be directed away from adjacent residential units. Drainage features include trench drains at sidewalk stormwater crossings, splashblocks, and equalizer pipes as shown on civil drawings. The project is designated as having an assured water supply per Arizona requirements, and development must conform to all applicable Queen Creek codes and ordinances. Contractor responsibilities include verifying existing utility locations, coordinating utility removal and relocation, ensuring ADA-accessible paths from parking to main entrances, and providing temporary pedestrian protection during construction.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ST

O

TO

N

IC

R

O

AD

STREET "A"

STREET "C"

ST

R

EE

T

"B

BASIN 2

13,640 SF

BASIN 1

56,500 SF

2319 24

41 2 3

11121314151618

Jan 21, 2026 Y:\MES\2024 Jobs\224295 - GRIC Dist 4 Subdiv 1&6 PreDevelopment\CAD Files\Exhibits\224295 - PRELIM LOT LAYOUT.dwgFILE:DATE:

GRIC D4 - SITE 1

PRELIMINARY LOT LAYOUT

DWG.

NO.

SHEET

NO.

TOTAL

SHEETS

CHECKED:DRAWN:DESIGNED:

DATE:DATE:DATE:

NO. BY DATE REVISION APPR. DATE

O: 602 263 1177

1001 N. CENTRAL AVE.,

SUITE 900

PHOENIX, AZ 85004

COLLABORATE. INNOVATE. CREATE.

CL

STREET "A"

STREET "C"

ST

R

EE

T

"B

BASIN 1

54,876 SF

BASIN 2

26,448 SF ST

O

TO

N

IC

R O

AD

7 6 5 3 1

3025 26 27 28 29

23 19202124 22

1817151413

Jan 21, 2026 Y:\MES\2024 Jobs\224295 - GRIC Dist 4 Subdiv 1&6 PreDevelopment\CAD Files\Exhibits\224295 - PRELIM LOT LAYOUT.dwgFILE:DATE:

GRIC D4 - SITE 6

PRELIMINARY LOT LAYOUT

DWG.

NO.

SHEET

NO.

TOTAL

SHEETS

CHECKED:DRAWN:DESIGNED:

DATE:DATE:DATE:

NO. BY DATE REVISION APPR. DATE

O: 602 263 1177

1001 N. CENTRAL AVE.,

SUITE 900

PHOENIX, AZ 85004

COLLABORATE. INNOVATE. CREATE.

CL

S T

R E

E T

B

PROPERTY LINE

PROPERTY LINE

PROPERTY LINE

PROPERTY LINE

S T

O T

O N

IC

R

O A

D

BASIN 2

13,640 SF

0.30 AC

BASIN 1

56,500 SF

0.50 AC

T Y

P

SETBACKS:

FRONT WITH SIDEWALKS: 35'-0"

SIDES FACING STREETS: 25'-0"

REAR: 15'-0"

IN BETWEEN: 10'-0"

0.52 AC

0.52 AC

0.52 AC

0.52 AC

0.52 AC

0.52 AC

0.52 AC

0.52 AC

0.52 AC

0.54 AC

0.52 AC

0.52 AC

0.52 AC

0.52 AC

0.52 AC

0.52 AC

0.52 AC

0.52 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

25'-0"

35'-0"

T Y

P

TYP.

25'-0"

TYP.

10'-0" TYP.

10'-0"

TYP.

10'-0"

10'-0"10'-0"

P U

E

R /W

R /W

PUE

10'-0"

R/W

40'-0"

P U

E

0.52 AC

LOT NUMBER

LOT SIZE

LEGEND:

EQUALIZER PIPE, SEE

CIVIL DRAWINGS

12 3 4 5678 91011 121314 15 161718

12 3 4 5678 91011 121314 15 161718

A

B

C

D

E

F

G

H

J

K

L

M

N

P

A

B

C

D

E

F

G

H

J

K

L

M

N

P

555 E FILLMORE ST, STE 100

PHOENIX ARIZONA 85004

P (602) 635 1581 F (602) 635 1581 cam@mergeAG.com cdc@mergeAG.com

DATE

SHEET

SHEET TITLE

COPYRIGHT

THIS DRAWING IS AN INSTRUMENT OF SERVICE

ONLY AND IS AND SHALL REMAIN, EXCLUSIVE

PROPERTY OF THE ARCHITECT. NO REPRODUCTION

OR OTHER USE SHALL BE MADE BY ANY PERSON

OR FIRM WITHOUT THE EXPRESS WRITTEN

PERMISSION OF THE ARCHITECT. ANY

UNAUTHORIZED USE SHALL VOID THE

ARCHITECT'S SEAL AND SIGNATURE HEREON AND

NO PROFESSIONAL LIABILITY WILL REMAIN.

PROJECT NO.

REVISION

SEAL

O W

N E R I N

F O

R M

A T

IO

N

P R O

JE

C

T

A001

07/01/2025

SITE 1 PLAN

G R

IC

D

F

E A

S

IB

IL

IT

Y

M A

S T

E R

P L A

N

D

IS

T R

IC

T

1. COORDINATE ALL SPOT ELEVATIONS, SLOPES AND DIMENSIONS WITH

CIVIL/LANDSCAPE/STRUCTURAL DRAWINGS

2. PROVIDE POSITIVE DRAINAGE OF 1% MINIMUM / 2% MAXIMUM AT ALL EXTERIOR

PAVED PEDESTRIAN AREAS SUCH AS SIDEWALKS, PATIOS, STAIRS, ETC. UNLESS

NOTED OTHERWISE

3. PROVIDE POSITIVE DRAINAGE AWAY FROM THE

4. BUILDING OF 5% FOR A DISTANCE OF 10 FEET UNLESS NOTED OTHERWISE.

5. FINISH GRADE SLOPES SHALL BE NO STEEPER THAN 1 FOOT VERTICAL IN 3 FEET

HORIZONTAL UNLESS NOTED OTHERWISE.

6. CONTRACTOR TO ENSURE THAT AN ACCESSIBLE PATH CONNECTS THE ADA

PARKING STALLS TO THE MAIN ENTRANC.

7. CONTRACTOR TO ENSURE POSITIVE DRAINAGE ACROSS ALL PAVED SURFACES.

GENERAL SHEET NOTES

1. TEMPORARY PEDESTRIAN PROTECTION SHALL BE PROVIDED WHERE REQUIRED

BY BUILDING USER'S TRAFFIC. COORDINATE WITH OWNER.

2. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES

BELOW GRADE AND RELATED SERVICES CONNECTIONS WITH THE RESPECTIVE

UTILITY COMPANIES.

3. CONTRACTOR SHALL COORDINATE THE REMOVAL, ABANDONMENT, AND/OR

RELOCATION OF EXITING UTILITIES ABOVE OR BELOW GRADE WITH THE

RESPECTIVE UTILITY COMPANIES.

4. SEE LANDSCAPE DRAWINGS FOR PLANTING & GROUND MATERIALS TO BE

INSTALLED.

5. DEVELOPMENT AND USE OF THIS SITE WILL CONFORM WITH ALL APPLICABLE

CODES & ORDINANCES.

6. THIS PROJECT IS LOCATED IN QUEEN CREEK, ARIZONA, AND HAS BEEN

DESIGNATED AS HAVING AN ASSURED WATER SUPPLY.

7. ALL NEW UTILITIES WILL BE PLACED UNDERGROUND U.N.O. SEE CIVIL

DRAWINGS.

8. ANY LIGHTING WILL BE REPLACED SO AS TO DIRECT LIGHT AWAY FROM

ADJACENT RESIDENTIAL UNITS AND WILL NOT EXCEED ONE FOOT CANDLE AT

THE PROPERTY LINE. NO NOISE, ODOR OR VIBRATION EMITTED BY USES IN THE

AREA OUTSIDE THE SITE.

9. ALL ROOFTOP AND GROUND EQUIPMENT AND SATELLITE DISHES SHALL BE

SCREENED TO THE HEIGHT OF THE TALLEST EQUIPMENT.

10. LOCATE IRRIGATION CONTROL BOXES ON LANDSCAPE DRAWINGS & SET TOP

LEVEL AT SIDEWALK LOCATIONS. PROVIDE CONCRETE BASE AND CASE FOR

PROTECTION AS INDICATED BY ARCHITECT.

11. REFER TO PLUMBING DRAWINGS AND EXTERIOR ELEVATIONS TO IDENTIFY

LOCATIONS OF OVERFLOW AND ROOF DRAIN LEADER DISCHARGE AREAS AND

PROVIDE SPLASHBLOCK OR RIP-RAP PER SITE AND CIVIL DRAWINGS.

12. PROVIDE TRENCH DRAINS AT ANY LOCATION WHERE STORMWATER CROSSES

ANY PEDESTRIAN SIDEWALK, SEE SITE DETAILS FOR TYPICAL DETAIL.

13. ALL CONCRETE AT SIDEWALKS, EQUIPMENT PADS, RAMPS AND STAIRS TO BE

PROVIDED WITH FIBER REINFORCING AS FOLLOWS: SYNTHETIC MICRO-FIBER

MONOFILAMENT POLYPROPYLENE MICRO-FIBERS ENGINEERED AND DESIGNED

FOR USE IN CONCRETE, COMPLYING WITH ASTM C 1116/C 1116M, TYPE III, 1/2

TO 1 1/2 INCHES LONG.

14. MAXIMUM CROSSSLOPES FOR SIDEWALKS NOT TO EXCEED 2.0%.

15. MINIMUM SLOPE AT SIDEWALKS FOR WATER DRAINAGE PURPOSES TO NO LESS

THAN 1.0% AND NOT TO EXCEED 2%.

16. SIDEWALK AND SLAB CONTROL JOINTS NOT SHOWN FOR DRAWING CLARITY;

CONTROL JOINTS TO BE PROVIDED AT 5'-0" O.C. MAXIMUM OR AT EQUAL SPACE

DISTRIBUTED ALONG THE LENGHT OF THE SURFACE. SEE ALSO SITE DETAILS.

17. SIDEWALK AND SLAB CONSTRUCTION/EXPANSION JOINTS NOT SHOWN FOR

DRAWING CLARITY; EXPANSION JOINTS TO BE PROVIDED AT 25'-0" O.C.

MAXIMUM OR AT EQUAL SPACE DISTRIBUTED ALONG THE LENGHT OF THE

SURFACE. SEE ALSO SITE DETAILS.

SITE GENERAL NOTES

1" = 50'-0"

SITE PLAN SITE 1 '

N

NUMBER DESCRIPTION DATE

S T

R E

E T

B

BASIN 2

26,448 SF

BASIN 1

54,876 SF

PROPERTY LINE

PROPERTY LINE

PROPERTY LINEPROPERTY LINE

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

0.50 AC

S T

O T

O N

IC

R

O A

D

SETBACKS:

FRONT WITH SIDEWALKS: 35'-0"

SIDES FACING STREETS: 25'-0"

REAR: 15'-0"

IN BETWEEN: 10'-0"

T Y

P

TYP.

25'-0"

T Y

P

TYP.

10'-0"

TYP.

10'-0"

P U

E

R /W

EQUALIZER PIPE,

SEE CIVIL

DRAWINGS

R /W

P U

E

P U

E

P U

E

'-0

10'-0"

R/W

40'-0"

PUE

10'-0"

PUE

10'-0"

0.52 AC

LOT NUMBER

LOT SIZE

LEGEND:

12 3 4 5678 91011 121314 15 161718

12 3 4 5678 91011 121314 15 161718

A

B

C

D

E

F

G

H

J

K

L

M

N

P

A

B

C

D

E

F

G

H

J

K

L

M

N

P

555 E FILLMORE ST, STE 100

PHOENIX ARIZONA 85004

P (602) 635 1581 F (602) 635 1581 cam@mergeAG.com cdc@mergeAG.com

DATE

SHEET

SHEET TITLE

COPYRIGHT

THIS DRAWING IS AN INSTRUMENT OF SERVICE

ONLY AND IS AND SHALL REMAIN, EXCLUSIVE

PROPERTY OF THE ARCHITECT. NO REPRODUCTION

OR OTHER USE SHALL BE MADE BY ANY PERSON

OR FIRM WITHOUT THE EXPRESS WRITTEN

PERMISSION OF THE ARCHITECT. ANY

UNAUTHORIZED USE SHALL VOID THE

ARCHITECT'S SEAL AND SIGNATURE HEREON AND

NO PROFESSIONAL LIABILITY WILL REMAIN.

PROJECT NO.

REVISION

SEAL

O W

N E R I N

F O

R M

A T

IO

N

P R O

JE

C

T

A002

07/01/2025

SITE 6 PLAN

G R

IC

D

F

E A

S

IB

IL

IT

Y

M A

S T

E R

P L A

N

D

IS

T R

IC

T

1. COORDINATE ALL SPOT ELEVATIONS, SLOPES AND DIMENSIONS WITH

CIVIL/LANDSCAPE/STRUCTURAL DRAWINGS

2. PROVIDE POSITIVE DRAINAGE OF 1% MINIMUM / 2% MAXIMUM AT ALL EXTERIOR

PAVED PEDESTRIAN AREAS SUCH AS SIDEWALKS, PATIOS, STAIRS, ETC. UNLESS

NOTED OTHERWISE

3. PROVIDE POSITIVE DRAINAGE AWAY FROM THE

4. BUILDING OF 5% FOR A DISTANCE OF 10 FEET UNLESS NOTED OTHERWISE.

5. FINISH GRADE SLOPES SHALL BE NO STEEPER THAN 1 FOOT VERTICAL IN 3 FEET

HORIZONTAL UNLESS NOTED OTHERWISE.

6. CONTRACTOR TO ENSURE THAT AN ACCESSIBLE PATH CONNECTS THE ADA

PARKING STALLS TO THE MAIN ENTRANC.

7. CONTRACTOR TO ENSURE POSITIVE DRAINAGE ACROSS ALL PAVED SURFACES.

GENERAL SHEET NOTES

1. TEMPORARY PEDESTRIAN PROTECTION SHALL BE PROVIDED WHERE REQUIRED

BY BUILDING USER'S TRAFFIC. COORDINATE WITH OWNER.

2. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES

BELOW GRADE AND RELATED SERVICES CONNECTIONS WITH THE RESPECTIVE

UTILITY COMPANIES.

3. CONTRACTOR SHALL COORDINATE THE REMOVAL, ABANDONMENT, AND/OR

RELOCATION OF EXITING UTILITIES ABOVE OR BELOW GRADE WITH THE

RESPECTIVE UTILITY COMPANIES.

4. SEE LANDSCAPE DRAWINGS FOR PLANTING & GROUND MATERIALS TO BE

INSTALLED.

5. DEVELOPMENT AND USE OF THIS SITE WILL CONFORM WITH ALL APPLICABLE

CODES & ORDINANCES.

6. THIS PROJECT IS LOCATED IN QUEEN CREEK, ARIZONA, AND HAS BEEN

DESIGNATED AS HAVING AN ASSURED WATER SUPPLY.

7. ALL NEW UTILITIES WILL BE PLACED UNDERGROUND U.N.O. SEE CIVIL

DRAWINGS.

8. ANY LIGHTING WILL BE REPLACED SO AS TO DIRECT LIGHT AWAY FROM

ADJACENT RESIDENTIAL UNITS AND WILL NOT EXCEED ONE FOOT CANDLE AT

THE PROPERTY LINE. NO NOISE, ODOR OR VIBRATION EMITTED BY USES IN THE

AREA OUTSIDE THE SITE.

9. ALL ROOFTOP AND GROUND EQUIPMENT AND SATELLITE DISHES SHALL BE

SCREENED TO THE HEIGHT OF THE TALLEST EQUIPMENT.

10. LOCATE IRRIGATION CONTROL BOXES ON LANDSCAPE DRAWINGS & SET TOP

LEVEL AT SIDEWALK LOCATIONS. PROVIDE CONCRETE BASE AND CASE FOR

PROTECTION AS INDICATED BY ARCHITECT.

11. REFER TO PLUMBING DRAWINGS AND EXTERIOR ELEVATIONS TO IDENTIFY

LOCATIONS OF OVERFLOW AND ROOF DRAIN LEADER DISCHARGE AREAS AND

PROVIDE SPLASHBLOCK OR RIP-RAP PER SITE AND CIVIL DRAWINGS.

12. PROVIDE TRENCH DRAINS AT ANY LOCATION WHERE STORMWATER CROSSES

ANY PEDESTRIAN SIDEWALK, SEE SITE DETAILS FOR TYPICAL DETAIL.

13. ALL CONCRETE AT SIDEWALKS, EQUIPMENT PADS, RAMPS AND STAIRS TO BE

PROVIDED WITH FIBER REINFORCING AS FOLLOWS: SYNTHETIC MICRO-FIBER

MONOFILAMENT POLYPROPYLENE MICRO-FIBERS ENGINEERED AND DESIGNED

FOR USE IN CONCRETE, COMPLYING WITH ASTM C 1116/C 1116M, TYPE III, 1/2

TO 1 1/2 INCHES LONG.

14. MAXIMUM CROSSSLOPES FOR SIDEWALKS NOT TO EXCEED 2.0%.

15. MINIMUM SLOPE AT SIDEWALKS FOR WATER DRAINAGE PURPOSES TO NO LESS

THAN 1.0% AND NOT TO EXCEED 2%.

16. SIDEWALK AND SLAB CONTROL JOINTS NOT SHOWN FOR DRAWING CLARITY;

CONTROL JOINTS TO BE PROVIDED AT 5'-0" O.C. MAXIMUM OR AT EQUAL SPACE

DISTRIBUTED ALONG THE LENGHT OF THE SURFACE. SEE ALSO SITE DETAILS.

17. SIDEWALK AND SLAB CONSTRUCTION/EXPANSION JOINTS NOT SHOWN FOR

DRAWING CLARITY; EXPANSION JOINTS TO BE PROVIDED AT 25'-0" O.C.

MAXIMUM OR AT EQUAL SPACE DISTRIBUTED ALONG THE LENGHT OF THE

SURFACE. SEE ALSO SITE DETAILS.

SITE GENERAL NOTES

1" = 50'-0"

SITE PLAN SITE 6 'N

NUMBER DESCRIPTION DATE

File details come from the government source that posted it. Updated .