This is a Bidder's Qualification Questionnaire document issued by the City of Fort Worth Purchasing Division for RFQt Ref. #26-0172 regarding Bulk Rock Salt procurement. The City of Fort Worth seeks bids to establish an agreement for bulk rock salt supply for the Transportation and Public Works Department on an as-needed basis. The questionnaire requires bidders to provide detailed technical specifications and product information to demonstrate responsiveness to the solicitation requirements.

Bidders must complete comprehensive chemical analysis data including weight percentages for sodium chloride, calcium sulfate, potassium chloride, sodium sulfate, and moisture content. Additional technical specifications required include screen analysis data showing U.S. sieve opening sizes and weight percentages retained, density measurement per cubic foot, disclosure of any additives in the product, and confirmation that the rock salt meets caking and free-flowing specifications. The responses provided in this questionnaire, combined with bid submittal information, will be used to evaluate bidder responsiveness and qualification for contract award.

View the file

Other files

File Type Posted
1-RFQt-02-Standard Purchasing Terms and Conditions.pdf PDF
4-RFQt-03-Specifications.pdf PDF
2-RFQt-01-Forms.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CITY OF FORT WORTH - PURCHASING DIVISION QUESTIONNAIRE

RFQt Ref. #: 26-0172
Doc. Ref#: RFQt-04
Page 2 of 4

RFQt Title: Bulk Rock Salt

1.0 BIDDER’S QUALIFICATION QUESTIONNAIRE

The information provided on this questionnaire and in the bid submittal will be used to determine the responsiveness of the bid. Please answer each question thoroughly. Answers may be provided on a separate sheet as long as each response is labeled according to the question.

1.1 Chemical Analysis Range (Please fill in the graph with the weight percent).

Constituent
Weight Percent

Sodium Chloride

Calcium Sulfate

Potassium Chloride

Sodium Sulfate

Moisture

1.2 Screen Analysis Range (Please fill in the graph with the opening inches and weight % Retained on)

U.S.

Sieve Opening, Inches Weight % Retained On

3/8

1/4

1.3 What is the density per cubic foot?

1.4. Are there any additives?

1.5.Is the size on-caking and free flowing?
________________________________________________________