This is a technical specifications attachment for a chlorine bulk storage tank testing and inspection request for quotation issued by the City of Fort Worth Water Department in Texas. The contract covers periodic testing and inspection services for nine liquid chlorine bulk storage tanks located across three water treatment facilities: Eagle Mountain Water Treatment Plant (two tanks), Rolling Hills Water Treatment Plant (two tanks), and Village Creek Water Treatment Plant (five tanks). The tanks vary in age and specifications, with four older tanks manufactured by Ace Buehler between 1983 and 1986 and five newer tanks manufactured by Tank & Vessel Builders installed in 2020. Tank capacities range from 5,000 to 5,300 gallons, with designed working pressures of 225 psi for the older tanks and 275 psi for the newer tanks. The older tanks were last tested between 2014 and October 2014, while the newly installed 2020 tanks have not yet been tested. All tanks are constructed to ASME standards, with the older tanks built to ASME Section 8, Division 1 specifications and the newer tanks constructed to ASME U W RT-1 HT standards.
The specification document provides detailed technical parameters for bidders, including shell and head thickness requirements, tank serial numbers, and manufacturer information necessary for contractors to understand the scope of work and develop accurate pricing. The City of Fort Worth is seeking bids on an "as needed" basis for this testing and inspection agreement, indicating a potential ongoing or flexible contract arrangement rather than a one-time engagement. No pricing terms, contract duration, award dates, or response deadlines are specified within this attachment, as it serves solely as a technical reference document detailing the assets requiring inspection and their current condition.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 4-RFQt-03-Specifications.pdf | ||
| 1-RFQt-02-Standard Purchasing Terms and Conditions.pdf | ||
| 2-RFQt-01-Forms.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Chlorine Bulk Storage Tank Testing
Background The Fort Worth Water Department owns and operates bulk liquid chlorine tanks that require periodic testing and inspection. This contract will cover the testing and inspection services for the following nine liquid chlorine bulk storage tanks:
| Location |
| Eagle Mnt. WTP |
6801 Bowman Roberts Eagle Mnt. WTP 6801 Bowman Roberts Rolling Hills WTP 2500 SE Loop 820 Rolling Hills WTP 2500 SE Loop 820 Village Creek 4500 Wilma lane Village Creek 4500 Wilma lane
| Village Creek 4500 Wilma Lane |
| Village Creek 4500 Wilma Lane |
| Village Creek 4500 Wilma Lane |
| Tank Serial Number |
| Serial 68587 |
| Serial 62039 |
| Serial 62536 |
| Serial 68586 |
| Serial 18079 |
| Serial 18078 |
| Serial 18075 |
| Serial 18076 |
| Serial 18077 |
| Date Last Tested |
| 2014 |
| 2014 |
| 10/2014 |
| 4/2014 |
| New tank installed |
New tank installed
| New tank installed 2020 |
| New tank installed 2020 |
| New tank installed 2020 |
| Manufacturer |
| Ace Buehler |
| Ace Buehler |
| Ace Buehler |
| Ace Buehler |
| Tank& Vessel Builders |
| Tank& Vessel Builders |
| Tank& Vessel Builders |
| Tank& Vessel Builders |
| Tank& Vessel Builders |
| Date of Manufacture |
| 1986 |
| 1983 |
| 1983 |
| 1986 |
| 2020 |
| 2020 |
| 2020 |
| 2020 |
| 2020 |
| Des. Working Pressure |
| 225 psi |
| 225 psi |
| 225 psi |
| 225 psi |
| 275 psi |
| 275 psi |
| 275 psi |
| 275 psi |
| 275 psi |
| Code |
| ASME Section 8, Div. 1 |
| ASME Section 8, Div. 1 |
| ASME Section 8, Div. 1 |
| ASME Section 8, Div. 1 |
| ASME U W RT-1 HT |
| ASME U W RT-1 HT |
| ASME U W RT-1 HT |
| ASME U W RT-1 HT |
| ASME U W RT-1 HT |
| Shell thickness (minimum in) |
| 0.625” |
| 0.625” |
| 0.625” |
| 0.625” |
| .625” |
| .625” |
| 0.625” |
| 0.625” |
| 0.625” |
| Head thickness (minimum in) |
| 0.625” |
| 0.625” |
| 0.625” |
| 0.625” |
| .750” |
| .750” |
| .750” |
| 750” |
| 750” |
| Tank Volume |
| 5,000 gallons |
| 5,000 gallons |
| 5,000 gallons |
| 5,000 gallons |
| 5,300 gallons |
| 5,300 gallons |
| 5,300 gallons |
| 5,300 gallons |
| 5,300 gallons |