3-Drawings - RPS Elton Hills ES Window Replacement - CDs Issued.pdf

PDF 7 MB Posted

Attached to
Elton Hills Elementary School Window Replacement
Solicitation number
032426
Issued by
Morrison County, Minnesota

About this file

RPS Elton Hills Elementary School Window Replacement - Construction Documents Summary

This is a comprehensive set of construction drawings and specifications for the Elton Hills Elementary School Window Replacement project in Rochester, Minnesota, prepared by CRW Architecture + Design Group and issued March 3, 2026. The project scope involves the complete replacement of all existing exterior aluminum windows with new thermally broken insulated aluminum storefront window systems throughout the facility. The work includes demolition of existing window assemblies, associated doors, louvers, and transom panels; installation of new insulated storefront systems with pre-finished aluminum components; and restoration of adjacent construction including hardcoat stucco repairs, interior partitions, and ceiling modifications. The construction documents include architectural demolition and construction plans, mechanical systems drawings addressing louver and damper reinstallation, and electrical plans detailing the removal and reinstallation of security devices, intercoms, door operators, and lighting controls that are mounted on or penetrate the existing window frames. The project is subject to the 2020 Minnesota State Building Code, 2020 Minnesota Accessibility Code, and 2024 Minnesota Energy Code requirements, with new exterior walls meeting minimum insulation requirements of R-13 plus 12.5 continuous insulation for climate zone 6.

The construction documents impose responsibility on the general contractor to obtain all required permits, coordinate with all trade contractors, verify existing conditions, and address any impractical design elements prior to construction. Contractors are responsible for safe removal and proper disposal of all demolition debris, with mechanical and electrical contractors required to salvage and reinstall specific existing equipment including door hardware, security system components, and motorized dampers. The project maintains the building's existing occupancy classification as Group E Education and Type II-B full sprinklered construction, adding no additional building square footage. Rochester Public Schools serves as the project owner, with Bill Burt (507-328-4505) as the primary contact, Troy Dokken of CRW Architecture as the architect contact, and Mike Szuberski of Dunham Engineering as the mechanical design contact.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OWNER

ARCHITECT

MECHANICAL DESIGN

ROCHESTER PUBLIC SCHOOLS

CONSTRUCTION SERVICES DEPARTMENT

393935 HIGHWAY 14 EAST

ROCHESTER, MINNESOTA 55904

CONTACT: BILL BURT

PHONE NUMBER: (507) 328-4505

EMAIL: wiburt@rochesterschools.org

CRW ARCHITECTURE + DESIGN GROUP

211 ELEVETH AVENUE NORTHWEST

ROCHESTER, MINNESOTA 55901

CONTACT: TROY DOKKEN

PHONE NUMBER: (507) 206-6201

EMAIL: tdokken@crwarchitecture.com

DUNHAM ENGINEERING

421 FIRST AVENUE SW - SUITE 201W

ROCHESTER, MINNESOTA 55902

CONTACT: MIKE SZUBERSKI

PHONE NUMBER: (507) 424-6868

EMAIL: mike.szuberski@dunhameng.com

N O

R T

H

SITE

ELTON HILLS DR N

W

15TH

A

V E

N W

26TH ST NW

14T H

A V

E N

W

SCHEDULE OF REQUIRED PERMITS

DESCRIPTION OF PERMIT TYPE

PERMIT ARRANGED FOR AND

PAID FOR BY:

= NOT APPLICABLE= BY OWNER= BY CONTRACTOR

12. SIGNAGE PERMIT

11. FOOTING & FOUNDATION PERMIT

(IF PHASED PERMIT REQUESTED)

10. ZONING & BUILDING REVIEW & PERMIT

9. SITE GRADING PERMIT

8. SEWER & WATER CONNECTION PERMIT

7. TELEPHONE PERMIT

6. CABLE TELEVISION PERMIT

5. GAS UTILITY PERMIT

4. ELECTRICAL UTILITY PERMIT

3. DRIVEWAY APPROACH PERMIT

2. SIDEWALK PERMIT (IF APPLICABLE)

1. DEMOLITION PERMIT

A

B

C

D

E

F

P

O

N

M

L

K

J

H

G

R

S

T

U

V

W I

STANDARD ABBREVIATIONS

W/O.

W.C.

WD.

WDW.

WT.

W.W.F.

W.W.M.

VAR.

V.C.T.

U.L.

UNFIN.

U.N.O.

T.&G.

TEMP.

THK.

T.O.

T.V.

TYP.

SCHD.

SECT.

S.F.

SHT.

SHTG.

SIM.

SIM.REV.

SPEC.

STD.

STL.

STOR.

STRUCT.

SUSP.

SYM.

R.D.

REBAR

REF.

REINF.

REQ.

REV.

RM.

R.O.

PC.

PERF.

P.LAM.

PLYW.

O.C.

OF.D.

O.H.D.

OPNG.

OPP.

O.S.B.

N.I.C.

NO. / #

NOM.

N.T.S.

MAINT.

MATL.

MAX.

MECH.

MEMB.

MEZZ.

MFR.

MIN.

MIR.

MISC.

M.O.

MTD.

MTL.

LAM.

LAV.

L.F.

KIT.

JAN.

I.D.

IN.

INFO.

INSUL.

INT.

H.C.

HCP.

HDR.

HDWD

HDWR.

H.M.

HORIZ

HR.

HT./HGT.

GA

GALV.

G.C.

GYP. BD.

F.D.

FDN.

F.E.

F.E.CAB.

F.F.E.

FLR.

F.O.

F.R.P.

FT.

FTG.

FURN.

F.V.

DBL.

DEPT.

DET.

D.F.

DIA./ Ø

DIAG.

DIM.

DISP.

DN.

DR.

DS.

DWG.

C.I.P.

C.J.

C/L / ℄

CLG.

CLR.

C.M.U.

COL.

COMP.

CONC.

CONST.

CONT.

COORD.

CORR.

CPT.

CT.

BD.

BLDG.

BM.

B.O

BRG.

ACC.

A.C.T.

ADD.

ADJ.

A.F.F.

ALT.

APPROX.

ARCH.

AVG.

EA.

E.I.F.S.

E.J.

ELEC.

ELEV.

ENTR.

EQ.

EQUIP.

EXP.

EXIST.

ACCORDING/ACCORDION

ACOUSTICAL CEILING TILE

ADDENDUM

ADJUSTABLE/ADJACENT

ABOVE FINISHED FLOOR

ALTERNATE/ALTERATION

APPROXIMATE

ARCHITECT/ARCHITECTURAL

AVERAGE

BOARD

BUILDING

BEAM

BOTTOM OF

BEARING

DOUBLE

DEPARTMENT

DETAIL

DRINKING FOUNTAIN

DIAMETER

DIAGONAL

DIMENSION

DISPOSAL

DOWN

DOOR

DOWNSPOUT

DRAWING

EACH

EXTERIOR INSUL. FINISH SYSTEM

EXPANSION JOINT

ELECTRICAL

ELEVATOR / ELEVATION

ENTRANCE

EQUAL

EQUIPMENT

EXPANSION

EXISTING

CAST IRON PIPE/CAST IN PLACE

CONTROL JOINT

CENTER-LINE

CEILING

CLEAR

CONCRETE MASONRY UNITS

COLUMN

COMPOSITE/COMPOSITION

CONCRETE

CONSTRUCTION

CONTINUOUS

COORDINATE

CORRIDOR

CARPET

CERAMIC TILE

FLOOR DRAIN

FOUNDATION

FIRE EXTINGUISHER

FIRE EXTINGUISHER CABINET

FINISH FLOOR ELEVATION

FLOOR

FACE OF

FIBERGLASS REINFORCED PANEL

FOOT OR FEET

FOOTING

FURNACE/FURNISH

FIELD VERIFY

GAUGE

GALVANIZED

GENERAL CONTRACTOR

GYPSUM BOARD

HOLLOW CORE

HANDICAP

HEADER

HARDWOOD

HARDWARE

HOLLOW METAL

HORIZONTAL

HOUR

HEIGHT

INSIDE DIMENSION

INCHES

INFORMATION

INSULATION

INTERIOR

LAMINATED

LAVATORY

LINEAL FOOT

KITCHEN

JANITOR

MAINTENANCE/MAINTAIN

MATERIAL

MAXIMUM

MECHANICAL

MEMBRANE

MEZZANINE

MANUFACTURER

MINIMUM/MINUTE

MIRROR

MISCELLANEOUS

MASONRY OPENING

MOUNTED

METAL

NOT IN CONTRACT

NUMBER

NOMINAL

NOT TO SCALE

ON CENTER

OVERFLOW DRAIN

OVERHEAD DOOR

OPENING

OPPOSITE

ORIENTED STRAND BOARD

PRECAST

PERFORATED

PLASTIC LAMINATE

PLYWOOD

ROOF DRAIN

REINFORCING BAR

REFERENCE/REFRIGERATOR

REINFORCED

REQUIRED

REVISION/REVERSE

ROOM

ROUGH OPENING

SCHEDULE

SECTION

SQUARE FEET

SHEET

SHEATHING

SIMILAR

SIMILAR REVERSE

SPECIFICATION

STANDARD

STEEL

STORAGE

STRUCTURE/STRUCTURAL

SUSPENDED

SYMBOL

TONGUE AND GROOVE

TEMPERED/TEMPORARY/TEMPERATURE

THICK

TOP OF

TELEVISION

TYPICAL

UNDERWRITERS LABORATORIES, INC.

UNFINISHED

UNLESS NOTED OTHERWISE

VARIES

VINYL-COMPOSITION TILE

WITHOUT

WATER CLOSET

WOOD

WINDOW

WEIGHT

WELDED WIRE FABRIC

WELDED WIRE MESH

O.F.C.I. OWNER FURNISHED

CONTRACTOR INSTALLED

GRAPHIC SYMBOLS

100A

ROOM TAG

Room Name

DOOR TAG

WINDOW TAG1t

WALL PARTITION TYPE

FIRE EXTINGUISHER CABINET

A101

SIM

F.E.C

F.E

ELEVATION NUMBER

SHEET NUMBER

BUILDING SECTION NUMBER

SHEET NUMBER

FIRE EXTINGUISHER CABINET

INTERIOR ELEVATION MARK

ELEVATION MARKER

A1.100

Ref

Ref

R e fR e f

XX

2h

A101

Ref

1Ref 1 Ref

Ref

Name Elevation

SHEET NUMBER

ISSUE/REVISION HISTORY

CHECKED BY

DRAWN BY

DATE

PROJECT

NUMBER

NUMBER DATE

OF SHEETS

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS

PREPARED BY ME OR UNDER MY

DIRECT SUPERVISION AND THAT I

AM A DULY LICENSED ARCHITECT

UNDER THE LAWS OF THE STATE OF

MINNESOTA.

© 2026 CRW architecture + design group

CONSTRUCTION DOCUMENT SET

No. ISSUED FOR DATE

211 11th ave nw rochester, mn 55901

p. 507.206.6201

f. 507.206.46.21 www.crwarchitecture.com

CLIENT

100% CDs 03/03/26

A u to d e s k D o c s

/R P

S E lt o n

H ill s E

S W in d o w R e p la c e m e n t/

-0

R P

S E lt o n H ill s E

S W in d o w

R e p la c e m e n t (R rv t

/4 /2

:4

:0

A M

G0.00

JASON WOODHOUSE

44421 03/03/2026

COVER SHEET

R O

C H

E S

T E

R M

IN

N

E S

O T

A

R P

S E

LT

O

N H

IL

LS

E S

W

IN

D O

W R

E P

L A

C E

M E

N T

26-009

03/03/2026

TMD,LG

JW

RPS ELTON HILLS ES WINDOW

REPLACEMENT

ROCHESTER MINNESOTA

PLANS ISSUED:03/03/2026

1-GENERAL INFORMATION

G0.00 COVER SHEET

2-ARCHITECTURAL DEMO

AD1.01 DEMO PLAN

AD1.21 DEMO REFLECTED CEILING PLAN

AD2.00 DEMO EXTERIOR ELEVATIONS

AD2.01 DEMO ENLARGED EXTERIOR ELEVATIONS

3-ARCHITECTURAL

A1.01 FLOOR PLAN

A1.21 REFLECTED CEILING PLAN

A2.00 EXTERIOR ELEVATIONS

A2.01 ENLARGED EXTERIOR ELEVATIONS

A4.10 DETAILS

A4.11 PARTIAL EXISTING PHOTO REFRENCE

4-MECHANICAL

M0 MECHANICAL SYMBOLS AND ABBREVIATIONS

M1 MECHANICAL PLANS

5-ELECTRICAL

E0 ELECTRICAL SYMBOLS AND ABBREVIATIONS

ED1 ELECTRICAL DEMOLITION PLAN

E1 ELECTRICAL PLAN

E2 ELECTRICAL PHOTOS

CODE INFORMATION: SHEET INDEXSITE LOCATION MAP

2020 MINNESOTA STATE BUILDING CODE

2020 MINNESOTA ACCESSIBILITY CODE

2024 MINNESOTA ENERGY CODE

PROPOSED PROJECT SUMMARY:

THE PROJECTS CONSIST OF REPLACING THE EXISTING EXTERIOR WINDOW SYSTEMS.

INSTALLING NEW EXTERIOR INSULATED STOREFRONT SYSTEMS.

WORK INCLUDES GENERAL, MECHANICAL AND ELECTRICAL SCOPE.

(NO ADDITIONAL BUILDING SQUARE FOOTAGE ADDED, CHANGE IN EXISTING BUILDING

SEPARATIONS AND MODIFICATIONS MADE TO EXISTING PARTITION RATINGS WITHIN THIS

PROJECT SCOPE)

OCCUPANCY CLASSIFICATION (CHAPTER 3):

GROUP E - EDUCATION (UNCHANGED)

TYPE OF CONSTRUCTION (CHAPTER 6):

TYPE II-B CONSTRUCTION, FULL SPRINKLERED (UNCHANGED)

2024 MINNESOTA ENERGY CODE

TABLE 5.5-6 BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 6

NEW EXTERIOR WALLS:

NON-RESIDENTIAL, INSULATION MIN. R-VALUE: R-13 + 12.5 C.I.

THE PROJECT CONSISTS OF THE REPLACEMENT OF AN EXISTING CURTAIN WALL SYSTEM

WITH NEW THERMALLY BROKEN INSULATED STOREFRONT WINDOW SYSTEM.

NO. REVISIONS DATE

DN

S B

S B

S B

DEMOLITION NOTES:

GENERAL DEMOLITION NOTES:

1. DASHED LINES REPRESENT EXISTING ITEMS TO BE REMOVED. U.N.O.

2. PROVIDE ALL WORK TO COMPLETE DEMOLITION AS MAY BE REQUIRED

TO ACCOMPLISH WORK AS SHOWN ON THE DRAWINGS UNLESS NOTED

OTHERWISE. ALL AS INDICATED OR REQUIRED RELATING TO THE

EXISTING BUILDING AND NOT OTHERWISE ASSIGNED IS INCLUDED

UNDER THE RESPONSIBILITY OF THE CONTRACTOR.

3. CONTRACTOR TO VERIFY EXISTING ELECTRICAL & PLUMBING

LOCATIONS PRIOR TO DEMOLITION. EXISTING PLUMBING AND

ELECTRICAL MAY REQUIRE MODIFICATION TO ACCOMPLISH THE NEW

DESIGN AS SHOWN ON THESE PLANS.

4. MECHANICAL, ELECTRICAL AND PLUMBING CONTRACTORS SHALL

TERMINATE ALL APPROPRIATE SERVICES TO EXISTING CONSTRUCTION

WHICH ARE TO BE PERMANENTLY DISCONNECTED. THEY SHALL

FURTHER MAKE ALL TEMPORARY SERVICE TERMINATIONS INDICATED

OR REQUIRED TO ACCOMPLISH THE DEMOLITION AND/OR NEW REVISED

OR REPLACED SERVICES AS PART OF WORK UNDER ALL CONTRACTS.

ALL PERMANENT TERMINATIONS SHALL BE REMOVED BACK TO THE

SOURCE. NO VACANT SERVICES SHALL BE LEFT IN PLACE.

5. CONTRACTORS ARE TO BE RESPONSIBLE FOR REMOVING AND HAULING

OF ALL DEMOLITION DEBRIS.

6. AT CONCLUSION OF DEMOLITION, ALL SURFACES SHALL BE READY TO

RECEIVE NEW FINISHES.

7. OWNER TO REMOVE/ RELOCATE FURNITURE, FIXTURES AND

EQUIPMENT, WITHIN CONSTRUCTION LIMITS, PRIOR TO START OF

CONSTRUCTION, COORDINATE PROJECT SCHEDULE WITH GENERAL

CONTRACTOR.

8. GENERAL CONTRACTOR IS RESPONSIBLE FOR EXISTING CONDITIONS

AND COORD. OF DRAWING INTENT. G.C. TO VERIFY EXISTING

CONDITIONS AND COORD. WITH ARCHITECT / ENGINEER TO ADJUST

PLANS FOR UNFORESEEN ISSUES. THE G.C. MUST ENSURE THE

DESIGN IS BUILDABLE WITH PRACTICAL MEANS AND METHODS,

FLAGGING ANY IMPRACTICAL ELEMENTS BEFORE CONSTRUCTION.

9. REMOVE AND SALVAGE ANY LOOSE BRICKS ALONG TOP OF WALLS FOR

SECURE REINSTALLATION PRIOR TO NEW BACKER ROD AND SEALANT.

1 REMOVE EXISTING STOREFRONT WINDOW IN ITS ENTIRETY AND

DISPOSE OF PROPERLY.

2 REMOVE EXISTING DOOR IN ITS ENTIRETY AND DISPOSE OF

PROPERLY. SALVAGE ALL EXISTING ELECTRONIC DOOR

HARDWARE AND SECURITY SYSTEM FOR REINSTALLATION.

(NOT ALL DEMOLITION NOTES APPEAR ON EVERY SHEET)

3 REMOVE EXISTING LOUVER IN ITS ENTIRETY AND DISPOSE OF

PROPERLY. SALVAGE EXISTING DAMPER FOR REINSTALLATION,

SEE MECH.

4 REMOVE EXISTING DOOR WEATHERSTIPPING AND DOOR SWEEP.

5 REMOVE EXISTING BLUE TRANSOM PANEL AND TRANSOM TOP

FRAME.

6 REMOVE EXISTING BLUE PANEL AND TRANSOM FRAME.

7 REMOVE EXISTING TRANSOM BLUE PANELS.

8 REMOVE EXISTING EXPOSED CONDUIT FOR PHOTO CELL DEVICE.

9 SALVAGE EXISTING METAL SILL CORNER GUARD FOR

REINSTALLLATION.

AD2.00

AD2.00

AD2.00

AD2.00

1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1

1 3

SHEET NUMBER

ISSUE/REVISION HISTORY

CHECKED BY

DRAWN BY

DATE

PROJECT

NUMBER

NUMBER DATE

OF SHEETS

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS

PREPARED BY ME OR UNDER MY

DIRECT SUPERVISION AND THAT I

AM A DULY LICENSED ARCHITECT

UNDER THE LAWS OF THE STATE OF

MINNESOTA.

© 2026 CRW architecture + design group

No. ISSUED FOR DATE

211 11th ave nw rochester, mn 55901

p. 507.206.6201

f. 507.206.46.21 www.crwarchitecture.com

CLIENT

100% CDs 03/03/26

A u to d e s k D o c s

/R P

S E lt o n

H ill s E

S W in d o w R e p la c e m e n t/

-0

R P

S E lt o n H ill s E

S W in d o w

R e p la c e m e n t (R rv t

/4 /2

:5

:5

A M

AD1.01

JASON WOODHOUSE

44421 03/03/2026

DEMO PLAN

R O

C H

E S

T E

R

M

IN

N

E S

O T

A

R P

S E

L T

O N

H

IL

L S

E S

W

IN

D O

W R

E P

L A

C E

M E

N T

26-009

03/03/2026

TMD,LG

JW

3/32" = 1'-0"

LEVEL 1 - DEMOLITION FLOOR PLAN NORTH

1 1 1 1 1 1 1 1 1 11 1 1 1 1

1111111111111

2 2 2 2 2 2 2 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 2 2 2 2 2

DEMOLITION CEILING NOTES:

2 REMOVE EXISTING WINDOW SHADE AND DISPOSE OF PROPERLY.

(NOT ALL DEMOLITION NOTES APPEAR ON EVERY SHEET)

1 REMOVE EXISTING CEILING TILE AND GRID FOR INSTALLATION OF

NEW WINDOW SCOPE.

3 REMOVE EXISTING FIBERGLASS SCREEN AND DISPOSE OF

PROPERLY.

GENERAL DEMOLITION NOTES:

1. DASHED LINES REPRESENT EXISTING ITEMS TO BE REMOVED. U.N.O.

2. PROVIDE ALL WORK TO COMPLETE DEMOLITION AS MAY BE REQUIRED

TO ACCOMPLISH WORK AS SHOWN ON THE DRAWINGS UNLESS

NOTED OTHERWISE. ALL AS INDICATED OR REQUIRED RELATING TO

THE EXISTING BUILDING AND NOT OTHERWISE ASSIGNED IS INCLUDED

UNDER THE RESPONSIBILITY OF THE CONTRACTOR.

3. CONTRACTOR TO VERIFY EXISTING ELECTRICAL & PLUMBING

LOCATIONS PRIOR TO DEMOLITION. EXISTING PLUMBING AND

ELECTRICAL MAY REQUIRE MODIFICATION TO ACCOMPLISH THE NEW

DESIGN AS SHOWN ON THESE PLANS.

4. MECHANICAL, ELECTRICAL AND PLUMBING CONTRACTORS SHALL

TERMINATE ALL APPROPRIATE SERVICES TO EXISTING CONSTRUCTION

WHICH ARE TO BE PERMANENTLY DISCONNECTED. THEY SHALL

FURTHER MAKE ALL TEMPORARY SERVICE TERMINATIONS INDICATED

OR REQUIRED TO ACCOMPLISH THE DEMOLITION AND/OR NEW

REVISED OR REPLACED SERVICES AS PART OF WORK UNDER ALL

CONTRACTS. ALL PERMANENT TERMINATIONS SHALL BE REMOVED

BACK TO THE SOURCE. NO VACANT SERVICES SHALL BE LEFT IN

PLACE.

5. CONTRACTORS ARE TO BE RESPONSIBLE FOR REMOVING AND

HAULING OF ALL DEMOLITION DEBRIS.

6. AT CONCLUSION OF DEMOLITION, ALL SURFACES SHALL BE READY TO

RECEIVE NEW FINISHES.

7. OWNER TO REMOVE/ RELOCATE FURNITURE, FIXTURES AND

EQUIPMENT, WITHIN CONSTRUCTION LIMITS, PRIOR TO START OF

CONSTRUCTION, COORDINATE PROJECT SCHEDULE WITH GENERAL

CONTRACTOR.

8. GENERAL CONTRACTOR IS RESPONSIBLE FOR EXISTING CONDITIONS

AND COORD. OF DRAWING INTENT. G.C. TO VERIFY EXISTING

CONDITIONS AND COORD. WITH ARCHITECT / ENGINEER TO ADJUST

PLANS FOR UNFORESEEN ISSUES. THE G.C. MUST ENSURE THE

DESIGN IS BUILDABLE WITH PRACTICAL MEANS AND METHODS,

FLAGGING ANY IMPRACTICAL ELEMENTS BEFORE CONSTRUCTION.

4 REMOVE PORTION OF EXISTING SOFFIT AT EXISTING JOINT FROM

A PREVIOUSLY DEMO.

5 REMOVE EXISTING EXPOSED CONDUIT FOR PHOTO CELL DEVICE

SHEET NUMBER

ISSUE/REVISION HISTORY

CHECKED BY

DRAWN BY

DATE

PROJECT

NUMBER

NUMBER DATE

OF SHEETS

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS

PREPARED BY ME OR UNDER MY

DIRECT SUPERVISION AND THAT I

AM A DULY LICENSED ARCHITECT

UNDER THE LAWS OF THE STATE OF

MINNESOTA.

© 2026 CRW architecture + design group

No. ISSUED FOR DATE

211 11th ave nw rochester, mn 55901

p. 507.206.6201

f. 507.206.46.21 www.crwarchitecture.com

CLIENT

100% CDs 03/03/26

A u to d e s k D o c s

/R P

S E lt o n

H ill s E

S W in d o w R e p la c e m e n t/

-0

R P

S E lt o n H ill s E

S W in d o w

R e p la c e m e n t (R rv t

/4 /2

:5

:5

A M

AD1.21

JASON WOODHOUSE

44421 03/03/2026

DEMO REFLECTED CEILING

PLAN

R O

C H

E S

T E

R

M

IN

N

E S

O T

A

R P

S E

L T

O N

H

IL

L S

E S

W

IN

D O

W R

E P

L A

C E

M E

N T

26-009

03/03/2026

TMD,LG

JW

3/32" = 1'-0"

LEVEL 1 - REFLECTED CEILING PLAN DEMO

NORTH

LEVEL 1

100' - 0"

B.O.ROOF

112' - 0"

Level 1A Top of Joists 110' - 0"

Level 3 top of gym 119' - 4"

AD2.01

1 ___________________

AD2.01

AD2.01

AD2.01

6 5

LEVEL 1

100' - 0"

B.O.ROOF

112' - 0"

Level 1A Top of Joists 110' - 0"

Level 3 top of gym 119' - 4"

AD2.01

7 7

4 4

LEVEL 1

100' - 0"

B.O.ROOF

112' - 0"

Level 1A Top of Joists 110' - 0"

Level 3 top of gym 119' - 4"

LEVEL 1

100' - 0"

B.O.ROOF

112' - 0"

Level 1A Top of Joists 110' - 0"

Level 3 top of gym 119' - 4"

AD2.01

DEMOLITION NOTES:

GENERAL DEMOLITION NOTES:

1. DASHED LINES REPRESENT EXISTING ITEMS TO BE REMOVED. U.N.O.

2. PROVIDE ALL WORK TO COMPLETE DEMOLITION AS MAY BE REQUIRED

TO ACCOMPLISH WORK AS SHOWN ON THE DRAWINGS UNLESS NOTED

OTHERWISE. ALL AS INDICATED OR REQUIRED RELATING TO THE

EXISTING BUILDING AND NOT OTHERWISE ASSIGNED IS INCLUDED

UNDER THE RESPONSIBILITY OF THE CONTRACTOR.

3. CONTRACTOR TO VERIFY EXISTING ELECTRICAL & PLUMBING

LOCATIONS PRIOR TO DEMOLITION. EXISTING PLUMBING AND

ELECTRICAL MAY REQUIRE MODIFICATION TO ACCOMPLISH THE NEW

DESIGN AS SHOWN ON THESE PLANS.

4. MECHANICAL, ELECTRICAL AND PLUMBING CONTRACTORS SHALL

TERMINATE ALL APPROPRIATE SERVICES TO EXISTING CONSTRUCTION

WHICH ARE TO BE PERMANENTLY DISCONNECTED. THEY SHALL

FURTHER MAKE ALL TEMPORARY SERVICE TERMINATIONS INDICATED

OR REQUIRED TO ACCOMPLISH THE DEMOLITION AND/OR NEW REVISED

OR REPLACED SERVICES AS PART OF WORK UNDER ALL CONTRACTS.

ALL PERMANENT TERMINATIONS SHALL BE REMOVED BACK TO THE

SOURCE. NO VACANT SERVICES SHALL BE LEFT IN PLACE.

5. CONTRACTORS ARE TO BE RESPONSIBLE FOR REMOVING AND HAULING

OF ALL DEMOLITION DEBRIS.

6. AT CONCLUSION OF DEMOLITION, ALL SURFACES SHALL BE READY TO

RECEIVE NEW FINISHES.

7. OWNER TO REMOVE/ RELOCATE FURNITURE, FIXTURES AND

EQUIPMENT, WITHIN CONSTRUCTION LIMITS, PRIOR TO START OF

CONSTRUCTION, COORDINATE PROJECT SCHEDULE WITH GENERAL

CONTRACTOR.

8. GENERAL CONTRACTOR IS RESPONSIBLE FOR EXISTING CONDITIONS

AND COORD. OF DRAWING INTENT. G.C. TO VERIFY EXISTING

CONDITIONS AND COORD. WITH ARCHITECT / ENGINEER TO ADJUST

PLANS FOR UNFORESEEN ISSUES. THE G.C. MUST ENSURE THE

DESIGN IS BUILDABLE WITH PRACTICAL MEANS AND METHODS,

FLAGGING ANY IMPRACTICAL ELEMENTS BEFORE CONSTRUCTION.

9. REMOVE AND SALVAGE ANY LOOSE BRICKS ALONG TOP OF WALLS FOR

SECURE REINSTALLATION PRIOR TO NEW BACKER ROD AND SEALANT.

1 REMOVE EXISTING STOREFRONT WINDOW IN ITS ENTIRETY AND

DISPOSE OF PROPERLY.

2 REMOVE EXISTING DOOR IN ITS ENTIRETY AND DISPOSE OF

PROPERLY. SALVAGE ALL EXISTING ELECTRONIC DOOR

HARDWARE AND SECURITY SYSTEM FOR REINSTALLATION.

(NOT ALL DEMOLITION NOTES APPEAR ON EVERY SHEET)

3 REMOVE EXISTING LOUVER IN ITS ENTIRETY AND DISPOSE OF

PROPERLY. SALVAGE EXISTING DAMPER FOR REINSTALLATION,

SEE MECH.

4 REMOVE EXISTING DOOR WEATHERSTIPPING AND DOOR SWEEP.

5 REMOVE EXISTING BLUE TRANSOM PANEL AND TRANSOM TOP

FRAME.

6 REMOVE EXISTING BLUE PANEL AND TRANSOM FRAME.

7 REMOVE EXISTING TRANSOM BLUE PANELS.

8 REMOVE EXISTING EXPOSED CONDUIT FOR PHOTO CELL DEVICE.

9 SALVAGE EXISTING METAL SILL CORNER GUARD FOR

REINSTALLLATION.

3/32" = 1'-0"

DEMO WEST ELEVATION

1/8" = 1'-0"

DEMO NORTH ELEVATION

3/32" = 1'-0"

DEMO EAST ELEVATION

1/8" = 1'-0"

DEMO SOUTH ELEVATION SHEET NUMBER

ISSUE/REVISION HISTORY

CHECKED BY

DRAWN BY

DATE

PROJECT

NUMBER

NUMBER DATE

OF SHEETS

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS

PREPARED BY ME OR UNDER MY

DIRECT SUPERVISION AND THAT I

AM A DULY LICENSED ARCHITECT

UNDER THE LAWS OF THE STATE OF

MINNESOTA.

© 2026 CRW architecture + design group

No. ISSUED FOR DATE

211 11th ave nw rochester, mn 55901

p. 507.206.6201

f. 507.206.46.21 www.crwarchitecture.com

CLIENT

100% CDs 03/03/26

A u to d e s k D o c s

/R P

S E lt o n

H ill s E

S W in d o w R e p la c e m e n t/

-0

R P

S E lt o n H ill s E

S W in d o w

R e p la c e m e n t (R rv t

/4 /2

:5

:0

A M

AD2.00

JASON WOODHOUSE

44421 03/03/2026

DEMO EXTERIOR

ELEVATIONS

R O

C H

E S

T E

R

M

IN

N

E S

O T

A

R P

S E

L T

O N

H

IL

L S

E S

W

IN

D O

W R

E P

L A

C E

M E

N T

26-009

03/03/2026

TMD,LG

JW

26' - 0"

V .I .F

23' - 10"

V .I

.F

6' - 4"13' - 4"6' - 4"

A4.10

26' - 0"

V .I

.F

26' - 0"

V .I

.F

V .I

.F

25' - 9"

SHEET NUMBER

ISSUE/REVISION HISTORY

CHECKED BY

DRAWN BY

DATE

PROJECT

NUMBER

NUMBER DATE

OF SHEETS

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS

PREPARED BY ME OR UNDER MY

DIRECT SUPERVISION AND THAT I

AM A DULY LICENSED ARCHITECT

UNDER THE LAWS OF THE STATE OF

MINNESOTA.

© 2026 CRW architecture + design group

No. ISSUED FOR DATE

211 11th ave nw rochester, mn 55901

p. 507.206.6201

f. 507.206.46.21 www.crwarchitecture.com

CLIENT

100% CDs 03/03/26

A u to d e s k D o c s

/R P

S E lt o n

H ill s E

S W in d o w R e p la c e m e n t/

-0

R P

S E lt o n H ill s E

S W in d o w

R e p la c e m e n t (R rv t

/4 /2

:5

:0

A M

AD2.01

JASON WOODHOUSE

44421 03/03/2026

DEMO ENLARGED EXTERIOR

ELEVATIONS

R O

C H

E S

T E

R

M

IN

N

E S

O T

A

R P

S E

L T

O N

H

IL

L S

E S

W

IN

D O

W R

E P

L A

C E

M E

N T

26-009

03/03/2026

TMD,LG

JW

1/2" = 1'-0"

DEMO PANEL A

1/2" = 1'-0"

DEMO PANEL B

1/2" = 1'-0"

DEMO PANEL C

1/2" = 1'-0"

DEMO PANEL D

1/2" = 1'-0"

DEMO PANEL E

1/2" = 1'-0"

DEMO PANEL F

B

S B

S B

1. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH ALL

REQUIREMENTS OF THE OWNER. EACH TRADE CONTRACTOR SHALL BE

RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL

SAFETY PROCEDURES, PRECAUTIONS AND PROGRAMS IN CONNECTION

WITH THEIR WORK.

2. THE GENERAL CONTRACTOR SHALL FILE FOR AND OBTAIN ALL REQUIRED

PERMITS, LETTERS OF SATISFACTORY COMPLETION AND CERTIFICATES

OF OCCUPANCY FROM THE LOCAL BUILDING OFFICIALS.

3. ALL EQUIPMENT SHOWN AS DASHED IS BY THE OWNER. ELECTRICAL

CONTRACTOR TO VERIFY POWER REQUIREMENTS FOR OWNER'S

EQUIPMENT. MECHANICAL CONTRACTOR TO VERIFY PLUMBING AND

HVAC REQUIREMENTS OF OWNER'S EQUIP.

4. REFER TO THE MECHANICAL, ELECTRICAL DRAWINGS FOR ADDITIONAL

WORK REQUIRED UNDER THIS CONTRACT.

5. THE GENERAL CONTRACTOR AND/OR MECHANICAL CONTRACTOR SHALL

COORDINATE ALL MECHANICAL WORK WITH THE OWNER'S

REPRESENTATIVE AND ALL OTHER TRADES.

6. THE GENERAL CONTRACTOR AND/OR ELECTRICAL CONTRACTOR SHALL

COORDINATE ALL ELECTRICAL WORK WITH THE OWNER'S

REPRESENTATIVE AND ALL OTHER TRADES.

GENERAL NOTES:

FLOOR PLAN NOTES:

1 NEW STOREFRONT WINDOW WITH INSULATED PANEL.

2 PATCH EXISTING CONCRETE SLAB EDGE

3 NEW LOUVER WITH REINSTALLED DAMPER, SEE MECH.

FOR SCOPE.

4 REPAIR EXISTING HARDCOAT STUCCO TO MATCH

ADJACENT SOFFIT COLOR AND TEXTURE

A2.00

A2.00

A2.00

A2.00

1 11 1 1 1 1 1 1 1

1111111111111

A4.10

A4.10

11 3

A4.10

101 102

SHEET NUMBER

ISSUE/REVISION HISTORY

CHECKED BY

DRAWN BY

DATE

PROJECT

NUMBER

NUMBER DATE

OF SHEETS

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS

PREPARED BY ME OR UNDER MY

DIRECT SUPERVISION AND THAT I

AM A DULY LICENSED ARCHITECT

UNDER THE LAWS OF THE STATE OF

MINNESOTA.

© 2026 CRW architecture + design group

No. ISSUED FOR DATE

211 11th ave nw rochester, mn 55901

p. 507.206.6201

f. 507.206.46.21 www.crwarchitecture.com

CLIENT

100% CDs 03/03/26

A u to d e s k D o c s

/R P

S E lt o n

H ill s E

S W in d o w R e p la c e m e n t/

-0

R P

S E lt o n H ill s E

S W in d o w

R e p la c e m e n t (R rv t

/4 /2

:4

:1

A M

A1.01

JASON WOODHOUSE

44421 03/03/2026

FLOOR PLAN

R O

C H

E S

T E

R M

IN

N

E S

O T

A

R P

S E

LT

O

N H

IL

LS

E S

W

IN

D O

W R

E P

L A

C E

M E

N T

26-009

03/03/2026

TMD,LG

JW

3/32" = 1'-0"

LEVEL 1 - FLOOR PLAN NORTH

1. MECHANICAL AND ELECTRICAL INFORMATION SHOWN IS INTENDED ONLY TO

COMMUNICATE DESIGN INTENT. REFER TO MECHANICAL AND ELECTRICAL

DRAWINGS FOR DETAILED INFORMATION. NOTIFY ARCHITECT/ENGINEER OF ANY

DISCREPANCIES NOTED PRIOR TO COMMENCEMENT OF WORK.

2. COORDINATE ALL CEILING MOUNTED EQUIPMENT SUPPORTS, DEVICE LOCATIONS,

CLEARANCES, ETC. WITH EQUIPMENT INSTALLERS AND SUPPLIERS PRIOR TO

INSTALLATION.

3. ACOUSTICAL PANEL CEILING GRIDS OR PANELS SHALL BE CENTERED IN ROOMS

UNLESS OTHERWISE NOTED OR DIMENSIONED.

4. ALL CEILING MOUNTED ITEMS (LIGHT FIXTURES, SPRINKLER HEADS, SPEAKERS,

ETC.) SHALL BE CENTERED IN ACOUSTICAL CEILING PANELS OR GYPSUM BOARD

SOFFITS UNLESS OTHERWISE NOTED OR DIMENSIONED.

5. SPACE LIGHT FIXTURES EVENLY IN ROOMS, BAYS, SPACES, ETC. AND CENTER

BETWEEN EXPOSED STRUCTURAL ELEMENTS WHERE APPROPRIATE.

6. DIMENSIONS TO CEILING-INSTALLED ITEMS ARE TO CENTERLINE OF FIXTURE OR

EQUIPMENT UNLESS NOTED OTHERWISE.

7. LOCATE CONTROL JOINTS IN GYPSUM BOARD CEILINGS, SOFFITS, BULKHEADS,

AND FASCIAS AS INDICATED ON DRAWINGS OR AS SPECIFIED AND TO ALIGN WITH

THOSE IN WALLS BELOW. VERIFY PROPOSED LAYOUT WITH ARCHITECT PRIOR TO

INSTALLATION.

8. PAINT ALL CONDUITS, DUCTWORK, SUPPORTS, HANGERS, ETC. THAT WILL REMAIN

EXPOSED TO VIEW. MATCH COLOR INDICATED FOR STRUCTURE UNLESS NOTED

OTHERWISE.

GENERAL CEILING NOTES:

ACOUSTICAL CEILING TILE (ACT-1)

CEILING TYPES LEGEND

CEILING PLAN NOTES:

2 PATCH HARD COAT STUCCO MATCHING EXISTING CONSTRUCTION AND

FINISH.

1 REINSTALL MODIFIED CEILING TILE AND GRID TO ALIGN WITH VERTICAL

MECH. PANEL.

3 NEW CONTINUOUS SOFFIT VENT.

1 1 1 1 1 1 1 1 11 1

1111111111111

A4.10

SHEET NUMBER

ISSUE/REVISION HISTORY

CHECKED BY

DRAWN BY

DATE

PROJECT

NUMBER

NUMBER DATE

OF SHEETS

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS

PREPARED BY ME OR UNDER MY

DIRECT SUPERVISION AND THAT I

AM A DULY LICENSED ARCHITECT

UNDER THE LAWS OF THE STATE OF

MINNESOTA.

© 2026 CRW architecture + design group

No. ISSUED FOR DATE

211 11th ave nw rochester, mn 55901

p. 507.206.6201

f. 507.206.46.21 www.crwarchitecture.com

CLIENT

100% CDs 03/03/26

A u to d e s k D o c s

/R P

S E lt o n

H ill s E

S W in d o w R e p la c e m e n t/

-0

R P

S E lt o n H ill s E

S W in d o w

R e p la c e m e n t (R rv t

/4 /2

:4

:1

A M

A1.21

JASON WOODHOUSE

44421 03/03/2026

REFLECTED CEILING PLAN

R O

C H

E S

T E

R M

IN

N

E S

O T

A

R P

S E

LT

O

N H

IL

LS

E S

W

IN

D O

W R

E P

L A

C E

M E

N T

26-009

03/03/2026

TMD,LG

JW

3/32" = 1'-0"

LEVEL 1 - REFLECTED CEILING PLAN NORTH

LEVEL 1

100' - 0"

B.O.ROOF

112' - 0"

Level 1 Finished Floor 100' - 0"

Level 1A Top of Joists 110' - 0"

Level 3 top of gym 119' - 4"

W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1W32

A4.10

W5

5 6

LEVEL 1

100' - 0"

B.O.ROOF

112' - 0"

Level 1A Top of Joists 110' - 0"

Level 3 top of gym 119' - 4"

W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W11

LEVEL 1

100' - 0"

B.O.ROOF

112' - 0"

Level 1 Finished Floor 100' - 0"

Level 1A Top of Joists 110' - 0"

Level 3 top of gym 119' - 4"

W2 W2

LEVEL 1

100' - 0"

B.O.ROOF

112' - 0"

Level 1 Finished Floor 100' - 0"

Level 1A Top of Joists 110' - 0"

Level 3 top of gym 119' - 4"

W43

1 CAULK AROUND EXISTING DOOR FRAME.

ELEVATION NOTES:

GENERAL REPAIR NOTES:

1. ALL SURFACE-MOUNTED FIXTURES AND ACCESSORIES

(LIGHTING, SPEAKERS, ETC.) REMOVED DURING

CONSTRUCTION ARE TO BE REINSTALLED IN THEIR

ORIGINAL LOCATION AT THE COMPLETION OF WORK

TO THAT AREA.

2. PROVIDE BACKER ROD AND SEALANT MISSING AT

STUCCO, BRICK AND ALUM. DOOR / WINDOW FRAMES.

3. PROVIDE NEW SEALANT AT FAILED SEALANT JOINTS

OF EXISTING TO REMAIN ALUM. DOOR / WINDOW

FRAMES.

4. NEW DOOR WEATHERSTRIPPING AND DOOR SWEEP AT

EXISTING ALUM. DOORS TO REMAIN.

2 NEW LOUVER WITH REINSTALLED DAMPER, SEE

MECH. FOR SCOPE.

3 REPAIR EXISTING HARDCOAT STUCCO TO

MATCH ADJACENT WALL COLOR AND TEXTURE

4 FABRICATED INSULATED ACM PANEL AND

BONDED INSULATION PANEL

5 NEW BLUE TRANSOM PANEL AND NEW

TRANSOM TOP FRAME.

6 INSTALL SALVAGED EXISTING METAL SILL

CORNER GUARD WITH NEW S.S. FASTENER.

SHEET NUMBER

ISSUE/REVISION HISTORY

CHECKED BY

DRAWN BY

DATE

PROJECT

NUMBER

NUMBER DATE

OF SHEETS

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS

PREPARED BY ME OR UNDER MY

DIRECT SUPERVISION AND THAT I

AM A DULY LICENSED ARCHITECT

UNDER THE LAWS OF THE STATE OF

MINNESOTA.

© 2026 CRW architecture + design group

No. ISSUED FOR DATE

211 11th ave nw rochester, mn 55901

p. 507.206.6201

f. 507.206.46.21 www.crwarchitecture.com

CLIENT

100% CDs 03/03/26

A u to d e s k D o c s

/R P

S E lt o n

H ill s E

S W in d o w R e p la c e m e n t/

-0

R P

S E lt o n H ill s E

S W in d o w

R e p la c e m e n t (R rv t

/4 /2

:4

:2

A M

A2.00

JASON WOODHOUSE

44421 03/03/2026

EXTERIOR ELEVATIONS

R O

C H

E S

T E

R M

IN

N

E S

O T

A

R P

S E

LT

O

N H

IL

LS

E S

W

IN

D O

W R

E P

L A

C E

M E

N T

26-009

03/03/2026

TMD,LG

JW

3/32" = 1'-0"

WEST ELEVATION

3/32" = 1'-0"

EAST ELEVATION

1/8" = 1'-0"

NORTH ELEVATION

1/8" = 1'-0"

SOUTH ELEVATION

26' - 0" - F.V.

6' - 6" 6' - 6" 6' - 6" 6' - 6" V

.I .F

/8

/8

F

.V

/8

/8

5' - 11" 6' - 0" 6' - 0" 5' - 11"

23' - 10" - F.V.

/8

/8

F

.V

V .I

.F

A4.10

6' - 4" 4' - 5" 4' - 6" 4' - 5" 6' - 4"

F

.V

26' - 0" - F.V.

25' - 9" - F.V.

4' - 4" 4' - 4" 4' - 2 1/2" 4' - 2 1/2" 4' - 4" 4' - 4"

F

.V

V .I

.F

V .I

.F

/8

17' - 4" - F.V.

4' - 4" 4' - 4" 4' - 4" 4' - 4"

4' - 2"

/8

F

.V

/8

1 CAULK AROUND EXISTING DOOR FRAME.

ELEVATION NOTES:

GENERAL REPAIR NOTES:

1. ALL SURFACE-MOUNTED FIXTURES AND ACCESSORIES

(LIGHTING, SPEAKERS, ETC.) REMOVED DURING

CONSTRUCTION ARE TO BE REINSTALLED IN THEIR

ORIGINAL LOCATION AT THE COMPLETION OF WORK

TO THAT AREA.

2. PROVIDE BACKER ROD AND SEALANT MISSING AT

STUCCO, BRICK AND ALUM. DOOR / WINDOW FRAMES.

3. PROVIDE NEW SEALANT AT FAILED SEALANT JOINTS

OF EXISTING TO REMAIN ALUM. DOOR / WINDOW

FRAMES.

4. NEW DOOR WEATHERSTRIPPING AND DOOR SWEEP AT

EXISTING ALUM. DOORS TO REMAIN.

2 NEW LOUVER WITH REINSTALLED DAMPER, SEE

MECH. FOR SCOPE.

3 REPAIR EXISTING HARDCOAT STUCCO TO

MATCH ADJACENT WALL COLOR AND TEXTURE

4 FABRICATED INSULATED ACM PANEL AND

BONDED INSULATION PANEL

5 NEW BLUE TRANSOM PANEL AND NEW

TRANSOM TOP FRAME.

6 INSTALL SALVAGED EXISTING METAL SILL

CORNER GUARD WITH NEW S.S. FASTENER.

SHEET NUMBER

ISSUE/REVISION HISTORY

CHECKED BY

DRAWN BY

DATE

PROJECT

NUMBER

NUMBER DATE

OF SHEETS

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS

PREPARED BY ME OR UNDER MY

DIRECT SUPERVISION AND THAT I

AM A DULY LICENSED ARCHITECT

UNDER THE LAWS OF THE STATE OF

MINNESOTA.

© 2026 CRW architecture + design group

No. ISSUED FOR DATE

211 11th ave nw rochester, mn 55901

p. 507.206.6201

f. 507.206.46.21 www.crwarchitecture.com

CLIENT

100% CDs 03/03/26

A u to d e s k D o c s

/R P

S E lt o n

H ill s E

S W in d o w R e p la c e m e n t/

-0

R P

S E lt o n H ill s E

S W in d o w

R e p la c e m e n t (R rv t

/4 /2

:4

:2

A M

A2.01

JASON WOODHOUSE

44421 03/03/2026

ENLARGED EXTERIOR

ELEVATIONS

R O

C H

E S

T E

R M

IN

N

E S

O T

A

R P

S E

LT

O

N H

IL

LS

E S

W

IN

D O

W R

E P

L A

C E

M E

N T

26-009

03/03/2026

TMD,LG

JW

1/2" = 1'-0"

W1 1/2" = 1'-0"

W2

1/2" = 1'-0"

W3 1/2" = 1'-0"

W4

1/2" = 1'-0"

W5

EXISTING MECHANICAL UNIT TO REMAIN

EXISTING WALL ASSEMBLY TO REMAIN

EXISTING MASONRY CAP TO REMAIN

CONT. SEALANT

1" INSULATED THERMALLY BROKEN

STOREFRONT WINDOW SYSTEM

PREFINISHED ALUM. BREAK METAL

SLOPE SILL

BACKER ROD AND SEALANT

CONTINUOUS NEOPRENE

GASKET BETWEEN WINDOW

AND FRAME CLOSURE

EXTERIOR WINDOW SYSTEM

PRE-FINISHED ALUM.

CLOSURE WITH HEMMED

EDGES TO MATCH WINDOW

SYSTEM - MECHANICALLY

ATTACH TO WINDOW MULLION

FALSE WINDOW MULLION

CENTERED ON EXISTING

INTERIOR PARTITION

BREAK METAL MULLION WITH

ACOUSTICAL INSULATION

CONTINUOUS SEALANT -

EACH SIDE OF WINDOW

FRAME

LINE OF WINDOW SILL BELOW

CONTINUOUS NEOPRENE

GASKET BETWEEN WINDOW

AND FRAME CLOSURE

EXTERIOR WINDOW SYSTEM

PRE-FINISHED ALUM.

CLOSURE WITH HEMMED

EDGES TO MATCH WINDOW

SYSTEM - MECHANICALLY

ATTACH TO WINDOW MULLION

FALSE WINDOW MULLION

CENTERED ON EXISTING

INTERIOR PARTITION

BREAK METAL FALSE MULLION

WITH ACOUSTICAL

INSULATION

CONTINUOUS SEALANT -

EACH SIDE OF WINDOW

FRAME

LINE OF WINDOW SILL BELOW

MODIFIED CEILING TILE

REMOVE AND REINSTALL

EXISTING ALUM. CLOSER ANGLE.

NEW BACKER ROD AND SEALANT

WOOD BLOCKING

2 1/2" THICK FABRICATED

INSULATED ACM PANEL AND

BONDED INSULATION PANEL

HORZ. ROLLER SHADE

EXISTING BRICK BEYOND

EXISTING BAR JOIST

EXISTING SUPPORT / BLOCKING MAY VARY.

CONTRACTOR SHALL PROVIDE NEW

SUPPORTS AND BLOCKING AS NECESSARY

EXISTING ALUM. FASCIA TO REMAIN.

CONTRACTOR SHALL REPAIR / REPLACE

FASCIA THAT BECOMES DAMAGED DURING

CONSTRUCTION

F.V.

6 1/2"

/4

LINE OF VERTICAL EXISTING MECH.

ENCLOSURE PANEL BEYOND

CEILING GRID EDGE TRIM TO PROVIDE

FINISHED TRANSITION. ALIGN WITH

VERRTICAL EXISTING MECH.

ENCLOSURE PANEL BEYOND

1" INSULATED THERMALLY BROKEN

STOREFRONT WINDOW SYSTEM

1" INSULATED THERMALLY BROKEN

STOREFRONT WINDOW SYSTEM

F.V. ALUM. BREAK METAL AND

FINISHED ENDS SHADE POCKET

WITH HEMMED EDGES. COLOR TO

MATCH EXISTING CEILING GRID

3/4" PLYWOOD

PREFINISHED BRAKE METAL

FLASHING MATCH FASCIA COLOR

EXISTING FASCIA FLASHING

EXISTING ALUM. PLATE

V A

R

IE

S

EXISTING CANOPY ROOF STRUCTURE

SUSPENDED CANOPY CEILING TO MATCH

EXISTING WITH STUCCO FINISH

WOOD BLOCKING

5/8" EXTERIOR SHEATHING

CLASS 'A' CLOSED CELL SPRAY FOAM INSULATION

3 5/8" METAL STUD

5/8" GYPSUM BOARD

2 X 6 WOOD STUD

EXISTING BAR JOIST AND

STRUCTURE ABOVE

CEILING GRID EDGE TRIM TO

PROVIDE FINISHED TRANSION

NEW MODIFIED CEILING TO

MATCH EXISTING

EXTERIOR SEALANT

1" INSULATED THERMALLY BROKEN

STOREFRONT WINDOW SYSTEM

PREFINISHED ALUM. FLASHING

BACKER ROD AND CONT. SEALANT

STUD BRACING, AS REQUIRED

SHEET NUMBER

ISSUE/REVISION HISTORY

CHECKED BY

DRAWN BY

DATE

PROJECT

NUMBER

NUMBER DATE

OF SHEETS

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS

PREPARED BY ME OR UNDER MY

DIRECT SUPERVISION AND THAT I

AM A DULY LICENSED ARCHITECT

UNDER THE LAWS OF THE STATE OF

MINNESOTA.

© 2026 CRW architecture + design group

No. ISSUED FOR DATE

211 11th ave nw rochester, mn 55901

p. 507.206.6201

f. 507.206.46.21 www.crwarchitecture.com

CLIENT

100% CDs 03/03/26

A u to d e s k D o c s

/R P

S E lt o n

H ill s E

S W in d o w R e p la c e m e n t/

-0

R P

S E lt o n H ill s E

S W in d o w

R e p la c e m e n t (R rv t

/4 /2

:4

:2

A M

A4.10

JASON WOODHOUSE

44421 03/03/2026

DETAILS

R O

C H

E S

T E

R M

IN

N

E S

O T

A

R P

S E

LT

O

N H

IL

LS

E S

W

IN

D O

W R

E P

L A

C E

M E

N T

26-009

03/03/2026

TMD,LG

JW

3" = 1'-0"

TYPICAL WINDOW SILL DETAIL

1 1/2" = 1'-0"

CMU WALL AT WINDOW

1 1/2" = 1'-0"

INTERIOR PARTITION AT WINDOW

3" = 1'-0"

TYPICAL INSULATED PANEL HEAD DETAIL

3" = 1'-0"

CANOPY SECTION AT STOREFRONT

B

S B

S B

3 54

6 78

9 10

14 1312

18 19

SHEET NUMBER

ISSUE/REVISION HISTORY

CHECKED BY

DRAWN BY

DATE

PROJECT

NUMBER

NUMBER DATE

OF SHEETS

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS

PREPARED BY ME OR UNDER MY

DIRECT SUPERVISION AND THAT I

AM A DULY LICENSED ARCHITECT

UNDER THE LAWS OF THE STATE OF

MINNESOTA.

© 2026 CRW architecture + design group

No. ISSUED FOR DATE

211 11th ave nw rochester, mn 55901

p. 507.206.6201

f. 507.206.46.21 www.crwarchitecture.com

CLIENT

100% CDs 03/03/26

A u to d e s k D o c s

/R P

S E lt o n

H ill s E

S W in d o w R e p la c e m e n t/

-0

R P

S E lt o n H ill s E

S W in d o w

R e p la c e m e n t (R rv t

/4 /2

:4

:3

A M

A4.11

JASON WOODHOUSE

44421 03/03/2026

PARTIAL EXISTING PHOTO

REFRENCE

R O

C H

E S

T E

R M

IN

N

E S

O T

A

R P

S E

LT

O

N H

IL

LS

E S

W

IN

D O

W R

E P

L A

C E

M E

N T

26-009

03/03/2026

TMD,LG

JW

1 2 6

7 8 9 10

NO. REVISIONS DATE

14 15

17 - typical classroom

18 19 20

MECHANICAL SYMBOLS LEGEND

DESIGNATIONSSYMBOLDESIGNATIONSSYMBOLDESIGNATIONSSYMBOL DESIGNATIONSSYMBOL

PLUMBING

ACID VENT

ACID WASTE

DEIONIZED WATER SUPPLY

FILTERED WATER

DOMESTIC HOT WATER

DOMESTIC HOT WATER (TEMP. INDICATED)

DOMESTIC RECIRC. HOT WATER

HARD COLD WATER

OVERFLOW STORM DRAIN

REVERSE OSMOSIS WATER

SANITARY VENT

SANITARY WASTE

SOIL DRAINAGE TILE

SOFTENED COLD WATER

SOFTENED HOT WATER

TEMPERED WATER

STORM DRAIN

WELL WATER

AV

AW

DIS

HARD

SDT

RO

V

W

SOFT

SHW

TW

OSD

SD

WW

NPCW NON-POTABLE COLD WATER

NPHW NON-POTABLE HOT WATER

FW

HW

RHW

GW GREASE WASTE

DOMESTIC COLD WATERCW

CLEAR WATER VENTCWV

CLEAR WATER WASTECWW

DOM. RECIRC. HOT WATER (TEMP. INDICATED)140 RHW

PUMPED ACID WASTEPAW

PUMPED STORMPSD

PUMPED WASTEPW

COMPRESSED AIR (PSI INDICATED)10#A

MECHANICAL PIPING

BOILER FEED

CHILLED WATER SUPPLY

CHILLED WATER RETURN

CONDENSATE DRAIN

CONDENSER WATER SUPPLY

CONDENSER WATER RETURN

FUEL OIL SUPPLY

FUEL OIL RETURN

FUEL OIL VENT

FUEL OIL FILL

GLYCOL SUPPLY

GLYCOL RETURN

HEAT RECOVERY SUPPLY

HEAT RECOVERY RETURN

HEATING WATER SUPPLY

HEATING WATER RETURN

LIQUIFIED PETROLEUM GAS

NATURAL GAS (PSI INDICATED)

PUMPED CONDENSATE

RADIATION WATER SUPPLY

RADIATION WATER RETURN

REFRIGERANT LIQUID

BF

CWS

CWR

CD

FOS

GS

GR

HRS

HRR

HWR

HWS

LPG

2#G

FOF

PC

RADS

CS

CR

FOR

FOV

RADR

RL

REFRIGERANT SUCTION

REFRIGERANT HOT GAS BYPASS

REHEAT WATER SUPPLY

REHEAT WATER RETURN

REMOTE RADIATOR SUPPLY

REMOTE RADIATOR RETURN

SECONDARY HEATING WATER SUPPLY

SECONDARY HEATING WATER RETURN

SNOW MELT SUPPLY

SNOW MELT RETURN

STEAM SUPPLY (PSI INDICATED)

STEAM CONDENSATE (PSI INDICATED)

RRS

RS

RHG

RHR

RHS

RRR

SHWS

SHWR

SMS

SMR

10#STM

10#SC

PIPE FITTINGS

ELBOW DOWN

PIPE CAP

ELBOW UP

TEE, OUTLET UP

TEE, OUTLET DOWN

CONNECTION, TOP

ECCENTRIC REDUCER

CONCENTRIC REDUCER

MEDICAL GAS

MEDICAL VACUUM

WASTE ANESTHETIC GAS DISPOSAL

CARBON DIOXIDE

OXYGEN

NITROGEN

NITROUS OXIDE

MEDICAL AIR

WAGD

CO2

O

N

MV

N2O

MA

PIPE UNION

PIPE FLANGE

ELBOW

TEE

FIRE PROTECTION

DFP

F FIRE PROTECTION

FIRE PROTECTION (DRY SYSTEM)

POST INDICATOR VALVE (PIV)

RECESSED FIRE DEPT CABINET

SURFACE MOUNTED FIRE DEPT CABINET

FIRE PROTECTION RISER

UPRIGHT SPRINKLER HEAD W/GUARD

PENDANT SPRINKLER HEAD

UPRIGHT SPRINKLER HEAD

SIDEWALL SPRINKLER HEAD

BUTTERFLY VALVE W/TAMPER SWITCH

DETECTOR CHECK W/BYPASS METER

GRADE FIRE DEPT CONNECTION

FLUSH FIRE DEPT CONNECTION

FIRE DEPT VALVE W/CAP AND CHAIN

O.S. & Y. VALVE W/TAMPER SWITCH

DRY PIPE VALVE

PREACTION VALVE

TS

FDVC

FDVC

FDV

TS

ANNOTATION

(4)A-12"ø

GRILLE, REGISTER, &

DIFFUSER IDENTIFICATION

QUANTITY

CFM

TYPE

SIZE

X X

X X

X X

X X

DETAIL NUMBER

SHEET NUMBER

SECTION NUMBER

SHEET NUMBER

EQUIP DESIGNATION

EQUIP NUMBER

POINT OF CONNECTION, NEW TO EXISTING

POINT OF DISCONNECTION

FTR/RP 01

6'-5"

0.5

HYDRONIC FINNED TUBE

RADIATION & RADIANT

PANEL IDENTIFICATION

TYPE ACTIVE

ELEMENT

LENGTHGPM

EBR 01

6'-5"

ELECTRIC BASEBOARD

RADIATION

IDENTIFICATION

ACTIVE

ELEMENT

LENGTH

ZONE VALVE BOXZVB

AREA ALARM PANELAAP

COMBINATION AREA/MASTER ALARM

PANEL

CAP

TYPE

INTERRUPTIBLE GASIG

PROCESS AND LABORATORY

LABORATORY AIR

LABORATORY VACUUM

ARGON

PROCESS WASTE

NITROGEN

HOUSE VACUUM

LV

AR

PRW

LA

N

HV

PROCESS VACUUMPV

INSTRUMENT AIRIA

ATMOSPHERIC STEAM SUPPLY

ATMOSPHERIC STEAM CONDENSATE

ATM STM

ATM SC

CONNECTION, BOTTOM

DARK DASHED LINE WEIGHT INDICATES

EXISTING ITEM TO BE DEMOLISHED.

GENERAL

LIGHT SOLID LINE WEIGHT INDICATES

EXISTING ITEM TO REMAIN.

DARK SOLID LINE WEIGHT INDICATES

NEW ITEM OR NEW LOCATION.

ROUND

12x12

12ø 12/12

RECTANGULAR (WxH)

FLAT-OVAL (W/H)

DUCT

DIMENSIONS

LIQUID NITROGENLN

MASTER ALARM PANELMAP

XXXX #-## EXISTING EQUIP NUMBER

EXISTING EQUIP DESIGNATION

MECHANICAL ABBREVIATIONS

AD AREA DRAIN

AFF ABOVE FINISHED FLOOR

AFMS AIR FLOW MEASURING STATION

AHU AIR HANDLING UNIT

ANB ACID NEUTRALIZING BASIN

AP ACCESS PANEL

ARCH ARCHITECT

AS AIR SEPARATOR

BD BUTTERFLY DAMPER

B/G BELOW GRADE

BTU BRITISH THERMAL UNIT

BWV BACKWATER VALVE

CCF HUNDRED CUBIC FEET

CFH CUBIC FEET PER HOUR

CFM CUBIC FEET PER MINUTE

CL CENTER LINE

CLG CEILING

CO CLEAN OUT

CONTR CONTRACTOR

CONV CONVECTOR

CUH CABINET UNIT HEATER

CW COLD WATER

DB DECIBEL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIFF DIFFUSER

DISCH DISCHARGE

DMPR DAMPER

DN DOWN

DR DRAIN

DSN DOWNSPOUT NOZZLE

DWG DRAWING

EAT ENTERING AIR TEMPERATURE

EDR EQUIVALENT DIRECT RADIATION

EP ELECTRIC-PNEUMATIC

EWC ELECTRIC WATER COOLER

EWT ENTERING WATER TEMPERATURE

EXH EXHAUST

EXP EXPANSION

F FAHRENHEIT

FC FAN COIL

FCO FLOOR CLEAN OUT

FD FLOOR DRAIN

FHC FIRE HOSE CABINET

FHR FIRE HOSE RACK

FLR FLOOR

FLEX FLEXIBLE

FM FIRE MAIN

FPM FEET PER MINUTE

FPS FEET PER SECOND

FT FEET OR FOOT

F&T FLOAT AND THERMOSTATIC

FTG FOOTING

FTR FINNED TUBE RADIATION

FV FACE VELOCITY

GA GAUGE

GAL GALLON

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

HB HOSE BIBB

HD HEAD

HOA HANDS-OFF-AUTOMATIC

HTG HEATING

HTR HEATER

HVAC HEATING, VENTILATION,

AND AIR CONDITIONING

HYD HYDRANT

HW HOT WATER

GCO GRADE CLEANOUT

INSUL INSULATION

KW KILOWATT

LAT LEAVING AIR TEMPERATURE

LAV LAVATORY

LWT LEAVING WATER TEMPERATURE

MBH BTU PER HOUR (THOUSANDS)

MCF THOUSAND CUBIC FEET

MH MANHOLE

NC

NOISE CRITERIA OR

NORMALLY CLOSED

NEG NEGATIVE

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NTS NOT TO SCALE

OA OUTSIDE AIR

OBD OPPOSED BLADE DAMPER

ORD OVERFLOW ROOF DRAIN

PD PRESSURE DROP OR DIFFERENCE

PE PNEUMATIC-ELECTRIC

PLBG PLUMBING

PRV

PRESSURE REDUCING VALVE

OR POWER ROOF VENTILATOR

PSIA POUNDS/SQ INCH ABSOLUTE

PSIG POUNDS/SQ INCH GAUGE

PVC POLY VINYL CHLORIDE

RA RETURN AIR

RCP REINFORCED CONCRETE PIPE

RD ROOF DRAIN

RECIRC RECIRCULATING

REG REGISTER

RET RETURN

RH RELATIVE HUMIDITY

RHT REHEAT

RHC REHEAT COIL

RHW RECIRCULATED HOT WATER

RM ROOM

RPM REVOLUTIONS PER MINUTE

RPZ

REDUCED ZONE BACKFLOW

PREVENTER

SA SUPPLY AIR

SAN SANITARY

SCFM CFM, STANDARD CONDITIONS

SD SMOKE DAMPER

SP STATIC PRESSURE

SPECS SPECIFICATIONS

SUP SUPPLY

SQ SQUARE

STM STEAM

TD TEMPERATURE DIFFERENCE

TEMP TEMPERATURE

TONS TONS OF REFRIGERATION

T-STAT THERMOSTAT

TYP TYPICAL

UB UP-BLAST

UG UNDERGROUND

UH UNIT HEATER

UR URINAL

V SANITARY VENT

VD VOLUME DAMPER

VEL VELOCITY

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

W SANITARY WASTE

W/ WITH

WC WATER CLOSET

WCO WALL CLEANOUT

WH WALL HYDRANT

W/O WITHOUT

WTR WATER

GR GRILLE

VAV VARIABLE AIR VOLUME

VTR VENT THROUGH ROOF

INV INVERT

RLF RELIEF

ISO ISOLATION EXHAUST

GEXH GREASE EXHAUST

RH ROOF HYDRANT

YCO YARD CLEANOUT

ZDL ZERO DEADLEG VALVE

AUTOMATIC AIR VENT

AUTOMATIC CONTROL VALVE, 2-WAY

AUTOMATIC CONTROL VALVE, 3-WAY

STRAINER W/BLOWDOWN

CAP AND VALVE

PIPE SPECIALTIES

FLEXIBLE CONNECTION

PIPE ANCHOR

ALIGNMENT GUIDE

STRAINER

PRESSURE REDUCING VALVE

(SETTING AS NOTED, PSI)

EXPANSION JOINT

MANUAL AIR VENT

PRESSURE RELIEF/SAFETY

VALVES(SETTING AS NOTED, PSI)

DRAIN VALVE

REDUCED PRESSURE ZONE BACK

FLOW PREVENTER

DIAPHRAGM

REFRIGERANT SIGHT GLASS

GAS PRESSURE REGULATOR VALVE

BACKWATER VALVE

REFRIGERANT DRYER

FLOW DIRECTION

FLOW DIRECTION W/PITCH

DUPLEX STRAINER

PUMP

THERMOMETER

PRESSURE/TEMPERATURE TEST PORT

STEAM TRAP (TYPE INDICATED)

FLOW SWITCH

PRESSURE GAUGE W/PIGTAIL &

PETCOCK

PRESSURE SWITCH

FLOOR DRAIN

DRAIN ABOVE

FLOOR SINK

WALL HYDRANT

HOSE BIBB

WALL CLEANOUT

ROOF DRAIN

MANHOLE

HB

A

M

FS

PS

GAS COCK VALVE

WH

DEIONIZED WATER RETURNDIR

CLEAN DRY AIRCDA

REVERSE OSMOSISRO

CONTROLS

AQUA STAT

TAMPERPROOF THERMOSTAT

HUMIDISTAT OR R.H. SENSOR

REFRIGERANT SENSOR

SMOKE DETECTOR

SPACE TEMPERATURE SENSOR

STATIC PRESSURE SENSOR

ROOM PRESSURE MONITOR

THERMOSTAT

THERMOSTAT W/GUARD

CARBON MONOXIDE SENSOR

CARBON DIOXIDE SENSOR

DIFFERENTIAL PRESSURE SENSOR

TEMPERATURE SENSOR

A

CO2

CO

H

R

P

SD

TS

SP

PS

T

T

T

DP

TS

P

DUCTWORK

SUPPLY AIR OR OUTDOOR AIR

RETURN AIR

EXHAUST AIR

STANDARD BRANCH, NO SPLITTER -

SUPPLY FLOW TO RIGHT -

RETURN/EXHAUST FLOW TO LEFT

BELLMOUTH WITH BALANCING

DAMPER

FLEXIBLE DUCT

TURNING VANES

FLEXIBLE CONNECTION

MANUAL VOLUME DAMPER

MOTORIZED DAMPER

TYPE:

FD = FIRE DAMPER

SD = SMOKE DAMPER

FSD = COMBINATION FIRE/SMOKE

DAMPER

CRD = CEILING RADIATION DAMPER

ORIENTATION:

SUPPLY GRILLE OR REGISTER

RETURN DUCT UP, NEGATIVE

PRESSURE

SUPPLY DIFFUSER/REGISTER

BLANKOFF INDICATED

RETURN OR EXHAUST GRILLE OR

REGISTER

SUPPLY DUCT UP, POSITIVE

PRESSURE

EXHAUST DUCT UP, NEGATIVE

PRESSURE

RETURN GRILLE/REGISTER

EXHAUST GRILLE/REGISTER

LINEAR DIFFUSER

CONCENTRIC DUCT TRANSITION

ECCENTRIC DUCT TRANSITION

RECTANGULAR-TO-ROUND DUCT

TRANSITION

VAV BOX

REHEAT COIL

VAV BOX W/ REHEAT COIL

DUCT OFFSETS

DUCT CUTLINE

M

XXX

RETURN DUCT DN, NEGATIVE

PRESSURE

SUPPLY DUCT DN, POSITIVE

PRESSURE

EXHAUST DUCT DN, NEGATIVE

PRESSURE

DROPRISE

VERTICAL

XXX

XXX

XXX

ACTUATOR (AS

APPLICABLE)

HORIZONTAL

BLADE/CURTAIN

FIRE, SMOKE, AND

COMBINATION

FIRE/SMOKE DAMPERS

TYPE

ORIENTATION

AIRFLOW MEASURING STATIONAFMS

VAV BOX W/ DUCT SILENCER

VENTURI TYPE AIR VALVE

VAV BOX W/ DUCT SILENCER

& REHEAT COIL

VAV BOX W/ ELECTRIC REHEAT

ENERGY METER

FLOW METER

GPM

EM

WATER HAMMER ARRESTOR

CATCH BASIN

BALANCE VALVE

GENERAL DUTY VALVES

CHECK VALVE

SHUTOFF VALVE

PLUG VALVE

BALL VALVE

BUTTERFLY VALVE

GLOBE ANGLE VALVE

O. S. & Y. VALVE

SOLENOID VALVE

FLOW LIMITING VALVE

GLOBE VALVE

S

OR

OR

OR

OR

OR

GATE VALVE

NITROGEN OXIDE SENSORNOX

SHEET NUMBER

ISSUE/REVISION HISTORY

CHECKED BY

DRAWN BY

DATE

PROJECT

NUMBER

NUMBER DATE

OF SHEETS

© 2025 CRW architecture + design group

No. ISSUED FOR DATE

211 11th ave nw rochester, mn 55901

p. 507.206.6201

f. 507.206.46.21 www.crwarchitecture.com

CLIENT

100% CDs 03/03/26

I HEREBY CERTIFY THAT THIS

PLAN, SPECIFICATION, OR REPORT

WAS PREPARED BY ME OR UNDER

MY DIRECT SUPERVISION AND

THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER

THE LAWS OF THE STATE OF

MINNESOTA.

Steven C Harmon

23501

A u to d e s k D o c s /R

P S

E lt o n

H ill s E

S W in d o w

R e p la c e m e n t/ M

E P

E lt o n

H ils

E S

W in d o w s R e p la c e m e n t (R rv t

/3 /2

:5

:5

A M

M0

03/03/26

MECHANICAL SYMBOLS AND

ABBREVIATIONS

R O

C H

E S

T E

R M

IN

N

E S

O T

A

R P

S E

L T

O N

H

IL

L S

E S

W

IN

D O

W R

E P

L A

C E

M E

N T

1226041

03/03/26

MJS

SCH

MECHANICAL SHEET LIST

SHEET

NUMBER SHEET NAME

M0 MECHANICAL SYMBOLS AND ABBREVIATIONS

M1 MECHANICAL PLANS

SHEET TOTAL: 2

M

DN

M

KEY NOTES: KEY NOTES:

BOILER

ROOM

CLASSROOM

CORRIDOR

DATA

150A

COMPUTER

150B

CORRIDOR

MEDIA

CLASSROOM

CLASSROOM

CLASSROOM

BOYS

STAFF

RESTROOM

STAFF

RESTROOM

GIRLS

SMALL

GROUP

RECEPTION/WAITING

NURSE

101A

MAIN OFFICE

BOILER

ROOM

CLASSROOM

CORRIDOR

DATA

150A

COMPUTER

150B

CORRIDOR

MEDIA

CLASSROOM

CLASSROOM

CLASSROOM

BOYS

STAFF

RESTROOM

STAFF

RESTROOM

GIRLS

SMALL

GROUP

RECEPTION/WAITING

NURSE

101A

MAIN OFFICE

1 LOUVER TO BE REMOVED BY GENERAL CONTRACTOR.

DISCONNECT CONTROL WIRING. REMOVE MOTORIZED DAMPER AND

DUCT SLEEVE. SAVE FOR REINSTALLATION.

1 NEW LOUVER BY GENERAL CONTRACTOR.

REINSTALL EXISTING MOTORIZED DAMPER AND DUCT SLEEVE.

PROVIDE TRANSITION TO NEW LOUVER. CONFIRM SIZE WITH

GENERAL CONTRACTOR. RECONNECT CONTROL WIRING.

SHEET NUMBER

ISSUE/REVISION HISTORY

CHECKED BY

DRAWN BY

DATE

PROJECT

NUMBER

NUMBER DATE

OF SHEETS

© 2025 CRW architecture + design group

No. ISSUED FOR DATE

211 11th ave nw rochester, mn 55901

p. 507.206.6201

f. 507.206.46.21 www.crwarchitecture.com

CLIENT

100% CDs 03/03/26

I HEREBY CERTIFY THAT THIS

PLAN, SPECIFICATION, OR REPORT

WAS PREPARED BY ME OR UNDER

MY DIRECT SUPERVISION AND

THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER

THE LAWS OF THE STATE OF

MINNESOTA.

Steven C Harmon

23501

A u to d e s k D o c s /R

P S

E lt o n

H ill s E

S W in d o w

R e p la c e m e n t/ M

E P

E lt o n

H ils

E S

W in d o w s R e p la c e m e n t (R rv t

/3 /2

:5

:5

A M

M1

03/03/26

MECHANICAL PLANS

R O

C H

E S

T E

R M

IN

N

E S

O T

A

R P

S E

L T

O N

H

IL

L S

E S

W

IN

D O

W R

E P

L A

C E

M E

N T

1226041

03/03/26

MJS

SCH

1/8" = 1'-0"

PARTIAL MECHANICAL DEMOLITION PLAN

1/8" = 1'-0"

PARTIAL MECHANICAL PLAN

DESIGNATIONSSYMBOL

MTG

HT

SYMBOL SCHEDULE NOTES

THESE SYMBOLS COMPRISE A STANDARD LIST, NOT ALL SYMBOLS MAY

APPEAR ON THESE DRAWINGS.

MOUNTING HEIGHTS INDICATED ARE STANDARD. DIMENSIONAL NUMBERS

INDICATED AT DEVICES SHALL OVERRIDE THESE STANDARDS. MOUNTED

HEIGHTS ARE TO THE CENTER OF THE DEVICE, UNLESS NOTED OTHERWISE.

MOUNTING HEIGHTS INDICATED ARE FOR STUD WALL CONSTRUCTION.

WHEN BLOCK OR BRICK CONSTRUCTION IS USED, ADJUST MOUNTING

HEIGHTS TO ALIGN DEVICE PLATES WITH RUNNING JOINT.

REFER TO SPECIFICATIONS FOR FURTHER INFORMATION.

GENERAL

DARK DASHED LINE WEIGHT INDICATES

EXISTING ITEM TO BE REMOVED.

LIGHT SOLID LINE WEIGHT INDICATES EXISTING

ITEM TO REMAIN.

DARK SOLID LINE WEIGHT INDICATES NEW ITEM

OR NEW LOCATION.

REMOVE EXISTING ITEM

REMOVE EXISTING ITEM AND RELOCATE AS INDICATED

NL

EXISTING ITEM TO REMAIN

NEW LOCATION FOR RELOCATED ITEM

NOTES & TAGS

EQUIPMENT IDENTIFICATION TAG - SEE EQUIPMENT SCHEDULES

FEEDER SIZE TAG - SEE POWER RISER SCHEDULE

ELEC EQUIP CONNECTION TAG - SEE EQUIP SCHEDULE

KEYNOTE

MISCELLANEOUS NOTE

#/C

XX

LIGHTING CONTROL SEQUENCE - SEE SCHEDULE

LC

XXX-X

RACEWAYS

CONDUIT CONCEALED IN CEILING OR WALLS

CONDUIT CONCEALED IN THE FLOOR OR BELOW

CONDUIT EXPOSED ON THE CEILING OR WALLS

CONDUIT BURIED UNDERGROUND (# = DEPTH)

CONDUIT WITH BEND DOWN

CONDUIT WITH BEND UP

CONDUIT WITH BUSHED END

CONDUIT WITH BREAK OR CONTINUATION

UG

CIRCUIT HOME RUN

- L1 INDICATES PANEL

- NUMBER

L1 1,3,5

JUNCTION BOX - WALL/CEILING MOUNT

WIREWAY, DUCT BANK, OR FLOOR DUCT AS NOTED

CABLE TRAY, TYPE/SIZE AS INDICATED

J J

X

R

RL

ELECTRICAL ABBREVIATIONS

AMPERES

ABOVE

ADDENDUM

AVAILABLE FAULT CURRENT

ABOVE FINISHED FLOOR

AIR HANDLING UNIT

ALUMINUM

ANTENNA

A, AMP

ABV

ADD

AFC

AFF

AHU

AL

ANT

ABOVE COUNTERAC

ARC FAULT CIRCUIT INTERRUPTERAFCI

BELOW FINISHED CEILING

BOLTED PRESSURE SWITCH

BFC

BPS

AUTOMATIC TRANSFER SWITCHATS

BUILDING AUTOMATION SYSTEMBAS

COPPER

DISTRIBUTED ANTENNA SYSTEM

ELECTRICAL CONTRACTOR

ELECTRIC OR ELECTRICAL

EMERGENCY

ELECTRICAL METALLIC TUBING

ENCLOSURE

ELECTRIC PNEUMATIC

EMERGENCY POWER OFF

CU

DAS

EC

ELEC

EM

EMT

ENCL

EP

EPO

CONDUIT OR CONTROLLED RECEPT

CIRCUIT BREAKER

CLOSED CIRCUIT TV

CIRCUIT

CABINET

C

CAB

CB

CCTV

CKT

ELECTRIC WATER COOLER

FUSE OR FUSED

FIRE ALARM

FLOOR BOX

FIRE-SMOKE DAMPER

GROUND

GROUND FAULT CIRCUIT INTERRUPTER

ISOLATED GROUND

JUNCTION BOX

KILOVOLT

KILOVOLT-AMP

KILOWATT

KILOWATT-HOUR

FILM VIEWER

EWC

F

FA

FB

FSD

FV

G, GND

GFI, GFCI

IG

JBOX

KV

KVA

KW

KWH

MAIN CIRCUIT BREAKER

MOMENTARY CONTACT OR

NATIONAL ELECTRICAL CODE

NOT IN CONTRACT

NOT TO SCALE

ON CENTER

PULL BOX OR PUSHBUTTON

NORMALLY OPEN

NORMALLY CLOSED

MAIN SWITCHBOARD

MC

MCB

MSB

NC

NEC

NIC

NO

NTS

OC

PB

MAIN LUG ONLYMLO

MOTOR RATED SWITCHMR

EMPTYMT

PNEUMATIC ELECTRIC

POWER FACTOR

PHASE

PRIMARY

PANEL

REFRIGERATOR

SECONDARY

SWITCH

SWITCHBOARD

SPEAKER

ROOF TOP UNIT

RECEPTACLE

TELEPHONE

PE

PF

PH

PNL

PRI

RECEPT

REFG

RTU

SEC

SW

SWBD

SPKR

TEL

TAMPER RESISTANTTR

THERMOSTAT

TYPICAL

UNDER COUNTER

UNDER GROUND

UNLESS NOTED OTHERWISE

VOLT OR VOLTAGE

VOLT-AMP

VOLTS ALTERNATING CURRENT

UNIT HEATER

VOLTS DIRECT CURRENT

WATT, WIRE OR WALL PHONE

WEATHERPROOF

EXISTING

TSTAT

TYP

UC

UG

UH

UNO

V

VA

VAC

VDC

W

WP

X

UNIVERSAL SERIAL BUSUSB

18"

18"

18"

18"

18"

18"

18"

VERIFY

VERIFY

VERIFY

VERIFY

VERIFY

VERIFY

VERIFY

VERIFY

VERIFY

18"

18"

18"

18"

BRANCH CIRCUIT PANEL

EQUIPMENT CABINET

TS=TRANSFER SWITCH

MOTOR OR MOTOR CONNECTION

MOTOR CONTROLLER, STARTER OR VFD

COMBINATION STARTER & DISCONNECT SWITCH

FUSED DISCONNECT SWITCH

MOTOR RATED TOGGLE

MANUAL MOTOR STARTER SWITCH WITH THERMAL

OVERLOAD

DUPLEX RECEPTACLE - WALL/CEILING MOUNT

EMERGENCY DUPLEX RECEPTACLE - WALL/CEILING

MOUNT

QUADPLEX RECEPTACLE - WALL/CEILING MOUNT

GFI RECEPTACLE, DUPLEX/QUADPLEX - WALL MOUNT

SPECIAL PURPOSE RECEPTACLE - WALL/CEILING

MOUNT

POKE-THRU - DEVICES AS INDICATED

POWER POLE - DEVICES AS INDICATED

EMERGENCY SPECIAL PURPOSE RECEPTACLE -

WALL/CEILING MOUNT

MR

MMS

G G

P

GFI DEAD FRONT DEVICE, NORMAL/EMERGENCY -

WALL MOUNT

C

SPLIT DUPLEX RECEPTACLE - WALL/CEILING MOUNT

SIMPLEX RECEPTACLE - WALL/CEILING MOUNT

EMERGENCY SIMPLEX RECEPTACLE - WALL/CEILING

MOUNT

DUPLEX RECEPTACLE - CONTROLLED - WALL/CEILING

MOUNT

EMERGENCY QUADPLEX RECEPTACLE - WALL/CEILING

MOUNT

GROUND REFERENCE BUS - AS NOTED - WALL/CEILING

MOUNT

VERIFY

EMERGENCY SPLIT DUPLEX RECEPTACLE -

WALL/CEILING MOUNT

LIGHT FIXTURE ID - REFER TO LIGHT FIXTURE SCHEDULE

(SCHEDULE OVERRIDES SYMBOL ABBREVIATION)

A - INDICATES LIGHT FIXTURE TYPE

# - INDICATES CIRCUIT NUMBER

b - INDICATES SWITCHING

LIGHT FIXTURE CIRCUIT TYPE

- NO HATCH INDICATES NORMAL CIRCUIT

- ANGLED HATCH INDICATES CRITICAL CIRCUIT

- SOLID HATCH INDICATES LIFE SAFETY CIRCUIT

TROFFER TYPE LIGHT FIXTURE, SIZE AS INDICATED -

CEILING MOUNT

CHANNEL OR INDUSTRIAL, LENGTH AS INDICATED

ROUND DOWNLIGHT, RECESSED OR SURFACE MOUNT

CEILING WALL WASH FIXTURE OR TRACK HEAD

WALL MOUNT FIXTURE OR SCONCE

LINEAR RECESSED, LENGTH AS INDICATED

UNDER CABINET FIXTURE, LENGTH AS INDICATED

TRACK FIXTURE, NUMBER OF HEADS AS INDICATED

EMERGENCY BATTERY LIGHT - WALL/CEILING MOUNT

EXIT LIGHT, FILLED QUADRANT INDICATES FACES -

WALL/CEILING MOUNT

VERIFY

SITE LIGHTING ROUND OR SQUARE BOLLARD

SITE LIGHTING POLE FIXTURE, ROUND/RECTANGLE

HEAD - NUMBER OF HEADS INDICATED

b

A

LINEAR SUSPENDED , LENGTH AS INDICATED VERIFY

VERIFY

SQUARE DOWNLIGHT, RECESSED OR SURFACE MOUNT

CHANNEL OR INDUSTRIAL WALL MOUNT, LENGTH AS

INDICATED

ROUND OR SQUARE PENDANT

TAPE OR ROPE LIGHT

VANITY FIXTURE

WALL PACK

FLAG OR FLOOD LIGHT

VERIFY

VERIFY

SINGLE POLE TOGGLE SWITCH

DOUBLE POLE TOGGLE SWITCH

THREE WAY TOGGLE SWITCH

FOUR WAY TOGGLE SWITCH

TOGGLE SWITCH - "a" INDICATES SWITCHING a

48"

PILOT LIGHT TOGGLE SWITCH

ILLUMINATED TOGGLE - TOGGLE SWITCH

KEYED SWITCH

MOMENTARY CONTACT TOGGLE SWITCH

TIMER SWITCH

DIMMER SWITCH

OCCUPANCY SENSOR - CLG MOUNT

OCCUPANCY SENSOR WALL SWITCH

PHOTO ELECTRIC CELL

TIME CLOCK

CONTACTOR

RELAY

IL

K

MC

TS

OS

PUSH BUTTON STATION - BUTTONS AS INDICATED

48"

48"

48"

48"

48"

48"

48"

48"

48"

48"

48"

48"

60"

60"

PC

TC

C

R

D

MULTI SWITCH, MULTI GANG BOX 48"

VERIFY

VERIFY

PUSH BUTTON SWITCHB 48"

SIGNAL AND COMMUNICATIONS

DATA OUTLET - WALL/CEILING MOUNT

(# = WIRE COUNTS)

VOICE/DATA OUTLET - WALL/CEILING MOUNT

FLOOR OUTLET (# = WIRE COUNTS)

WALL PHONE - HIGH WALL MOUNT

WIRELESS ACCESS POINT - WALL/CEILING MOUNT

18"

SPEAKER - WALL/CEILING MOUNT

HORN SPEAKER - WALL MOUNT

VOLUME SWITCH - WALL MOUNT

AUDIO JACK (M=MICROPHONE, A=AUXILIARY)

BUZZER - WALL/CEILING MOUNT

BELL - WALL/CEILING MOUNT

CHIME - WALL/CEILING MOUNT

CLOCK - WALL/CEILING MOUNT (# = DIAMETER)

PROJECTOR/VIDEO CAMERA/DOCUMENT

CAMERA - WALL/CEILING MOUNT

TV SYSTEM OUTLET - WALL/CEILING MOUNT

ANNUNCIATOR PANEL - WALL MOUNT TYPICAL

60"

96"

48"

18"

96"

VERIFY

18"

WALL INTERCOM STATION (M=MASTER, R=REMOTE) 48"

96"

96"

96"

18"

96"

W

PRJ

AUDIO VIDEO SYSTEM OUTLET - WALL/CEILING MOUNT 18"

A/V SYSTEMS CONTROLLER - WALL MOUNT 18"

S

S S

C C

ICM

AM

V

VID

SECURITY

SECURITY - WALL MOUNT - TYPICAL

ES

EL

DC

GB

48"

SECURITY PANEL - WALL MOUNT - TYPICAL VERIFY

S

S

SECURITY CAMERA - WALL/CEILING MOUNT

VERIFY

CR

EP

SECURITY - CEILING MOUNT - TYPICAL

SWITCHES AND CONTROLS

LIGHTING

POWER

A.

B.

C.

D.

TRANSFORMERXFMR

ABOVE GRADEAG

AUDIBLE ALARMAA

CEILING CLG

DOWNDN

DEDICATEDDED

COMMUNICATIONSCOMM

CONTROL CTRL

FIRE ALARM ANNUNCIATOR PANELFAAP

FIRE ALARM CONTROL PANELFACP

FIBER OPTICFO

SINGLE MODE FIBER OPTICSMFO

MULTI MODE FIBER OPTICMMFO

GROUND FAULT EQUIPMENT PROTECTIONGFEP

GENERAL CONTRACTORGC

CURRENT TRANSFORMERCT

ABOVE COUNTER HEIGHTACH

AUDIO VISUALAV

AMERICAN WIRE GAUGEAWG

MOTOR CONTROL CENTERMCC

METER M

MAN HOLEMH

NEUTRALN

HAND HOLEHH

HAND OFF AUTOHOA

POTENTIAL TRANSFORMERPT

MECHANICAL CONTRACTOR

RACEWAYR

UNDER FLOORUF

WIRELESS ACCESS POINTWAP

SHIELDED TWISTED PAIRSTP

SUBSTATIONSUB

UNSHIELDED TWISTED PAIRUTP

ELECTRICAL GROUND BAREGB

SERVICE GROUND BARSGB

TELECOMMUNICATIONSTELCOM

TELECOMMUNICATIONS MAIN GROUND BARTMGB

TELECOMMUNICATIONS GROUND BARTGB

DESIGNATIONSSYMBOL

MTG

HT

DESIGNATIONSSYMBOL

MTG

HT

ELECTRICAL SYMBOLS LEGEND

VERIFY

VERIFY

C

18"

A/V MONITOR - WALL MOUNT 18"MT

CX

AV

TV

AV

TV

X" H X" W

X' - X" AFF

CABLE TRAY TAG

X" W - WIDTH OF CABLE TRAY

X" H - HEIGHT OF CABLE TRAY

X' - X" AFF - MOUNTING HEIGHT OF CABLE TRAY (FROM FINISH

FLOOR TO BOTTOM OF TRAY)

GFI RECEPTACLE, DUPLEX/QUADPLEX - CEILING MOUNT

18"

UTILITY SERVICE:

EQUIPMENT ID

VOLTAGE, PHASE, 3 OR 4 WIRE

ONE LINE AND RISER

ID

V, Ø, W

XX

AF/AT

XX

AF/AT

XX

AF/AT

XX

AF/AT

600 VOLT MOLDED CASE CIRCUIT BREAKER:

AF = AMP FRAME, AT = AMP TRIP

XX = OPTIONS TO BE PROVIDED, MAY BE BLANK

OPTIONS ABBREVIATIONS:

LSI = LONG TIME/SHORT TIME/INSTANTANEOUS TRIP SETTINGS

LSIG = LSI WITH GROUND FAULT PROTECTION

EO=ELECTRICALLY OPERATED

M1=METER (REFER TO METER SCHEDULE)

ST=SHUNT TRIP

K1=KIRK KEYED (REFER TO KIRK KEY SCHEDULE)

600 VOLT INSULATED CASE CIRCUIT BREAKER:

AF = AMP FRAME, AT = AMP TRIP

XX = OPTIONS TO BE PROVIDED, MAY BE BLANK

600 VOLT DRAWOUT CIRCUIT BREAKER:

AF = AMP FRAME, AT = AMP TRIP

XX = OPTIONS TO BE PROVIDED, MAY BE BLANK

15,000 VOLT DRAWOUT CIRCUIT BREAKER:

AF = AMP FRAME, AT = AMP TRIP

XX = OPTIONS TO BE PROVIDED, MAY BE BLANK

K1

M A V

M M M

MMM

XX

ID

V, Ø, W

A MCB

SPACES

KAIC

XX

AS

DISCONNECT SWITCH:

AS = AMP SWITCH

XX = OPTIONS TO BE PROVIDED, MAY BE BLANK

XX

AF

FUSE:

AF = AMP FUSE

XX = OPTIONS TO BE PROVIDED, MAY BE BLANK

XX

AS/AF

FUSED DISCONNECT SWITCH:

AS = AMP SWITCH, AF = AMP FUSE

XX = OPTIONS TO BE PROVIDED, MAY BE BLANK

ID

KVA

V

MF

ID

V, Ø, W A

XX

KAIC

ID

HP

Ø

ID

KW/KVA

V, Ø, W

PF

ENGINE GENERATOR:

EQUIPMENT ID

KW/KVA RATING OF GENERATOR

VOLTAGE, PHASE, 3 OR 4 WIRE, POWER FACTOR

TRANSFER SWITCH:

EQUIPMENT ID

VOL…