3-Drawings - RPS Elton Hills ES Window Replacement - CDs Issued.pdf
PDF 7 MB Posted
- Attached to
- Elton Hills Elementary School Window Replacement
- Solicitation number
- 032426
- Issued by
- Morrison County, Minnesota
About this file
RPS Elton Hills Elementary School Window Replacement - Construction Documents Summary
This is a comprehensive set of construction drawings and specifications for the Elton Hills Elementary School Window Replacement project in Rochester, Minnesota, prepared by CRW Architecture + Design Group and issued March 3, 2026. The project scope involves the complete replacement of all existing exterior aluminum windows with new thermally broken insulated aluminum storefront window systems throughout the facility. The work includes demolition of existing window assemblies, associated doors, louvers, and transom panels; installation of new insulated storefront systems with pre-finished aluminum components; and restoration of adjacent construction including hardcoat stucco repairs, interior partitions, and ceiling modifications. The construction documents include architectural demolition and construction plans, mechanical systems drawings addressing louver and damper reinstallation, and electrical plans detailing the removal and reinstallation of security devices, intercoms, door operators, and lighting controls that are mounted on or penetrate the existing window frames. The project is subject to the 2020 Minnesota State Building Code, 2020 Minnesota Accessibility Code, and 2024 Minnesota Energy Code requirements, with new exterior walls meeting minimum insulation requirements of R-13 plus 12.5 continuous insulation for climate zone 6.
The construction documents impose responsibility on the general contractor to obtain all required permits, coordinate with all trade contractors, verify existing conditions, and address any impractical design elements prior to construction. Contractors are responsible for safe removal and proper disposal of all demolition debris, with mechanical and electrical contractors required to salvage and reinstall specific existing equipment including door hardware, security system components, and motorized dampers. The project maintains the building's existing occupancy classification as Group E Education and Type II-B full sprinklered construction, adding no additional building square footage. Rochester Public Schools serves as the project owner, with Bill Burt (507-328-4505) as the primary contact, Troy Dokken of CRW Architecture as the architect contact, and Mike Szuberski of Dunham Engineering as the mechanical design contact.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OWNER
ARCHITECT
MECHANICAL DESIGN
ROCHESTER PUBLIC SCHOOLS
CONSTRUCTION SERVICES DEPARTMENT
393935 HIGHWAY 14 EAST
ROCHESTER, MINNESOTA 55904
CONTACT: BILL BURT
PHONE NUMBER: (507) 328-4505
EMAIL: wiburt@rochesterschools.org
CRW ARCHITECTURE + DESIGN GROUP
211 ELEVETH AVENUE NORTHWEST
ROCHESTER, MINNESOTA 55901
CONTACT: TROY DOKKEN
PHONE NUMBER: (507) 206-6201
EMAIL: tdokken@crwarchitecture.com
DUNHAM ENGINEERING
421 FIRST AVENUE SW - SUITE 201W
ROCHESTER, MINNESOTA 55902
CONTACT: MIKE SZUBERSKI
PHONE NUMBER: (507) 424-6868
EMAIL: mike.szuberski@dunhameng.com
N O
R T
H
SITE
ELTON HILLS DR N
W
15TH
A
V E
N W
26TH ST NW
14T H
A V
E N
W
SCHEDULE OF REQUIRED PERMITS
DESCRIPTION OF PERMIT TYPE
PERMIT ARRANGED FOR AND
PAID FOR BY:
= NOT APPLICABLE= BY OWNER= BY CONTRACTOR
12. SIGNAGE PERMIT
11. FOOTING & FOUNDATION PERMIT
(IF PHASED PERMIT REQUESTED)
10. ZONING & BUILDING REVIEW & PERMIT
9. SITE GRADING PERMIT
8. SEWER & WATER CONNECTION PERMIT
7. TELEPHONE PERMIT
6. CABLE TELEVISION PERMIT
5. GAS UTILITY PERMIT
4. ELECTRICAL UTILITY PERMIT
3. DRIVEWAY APPROACH PERMIT
2. SIDEWALK PERMIT (IF APPLICABLE)
1. DEMOLITION PERMIT
A
B
C
D
E
F
P
O
N
M
L
K
J
H
G
R
S
T
U
V
W I
STANDARD ABBREVIATIONS
W/O.
W.C.
WD.
WDW.
WT.
W.W.F.
W.W.M.
VAR.
V.C.T.
U.L.
UNFIN.
U.N.O.
T.&G.
TEMP.
THK.
T.O.
T.V.
TYP.
SCHD.
SECT.
S.F.
SHT.
SHTG.
SIM.
SIM.REV.
SPEC.
STD.
STL.
STOR.
STRUCT.
SUSP.
SYM.
R.D.
REBAR
REF.
REINF.
REQ.
REV.
RM.
R.O.
PC.
PERF.
P.LAM.
PLYW.
O.C.
OF.D.
O.H.D.
OPNG.
OPP.
O.S.B.
N.I.C.
NO. / #
NOM.
N.T.S.
MAINT.
MATL.
MAX.
MECH.
MEMB.
MEZZ.
MFR.
MIN.
MIR.
MISC.
M.O.
MTD.
MTL.
LAM.
LAV.
L.F.
KIT.
JAN.
I.D.
IN.
INFO.
INSUL.
INT.
H.C.
HCP.
HDR.
HDWD
HDWR.
H.M.
HORIZ
HR.
HT./HGT.
GA
GALV.
G.C.
GYP. BD.
F.D.
FDN.
F.E.
F.E.CAB.
F.F.E.
FLR.
F.O.
F.R.P.
FT.
FTG.
FURN.
F.V.
DBL.
DEPT.
DET.
D.F.
DIA./ Ø
DIAG.
DIM.
DISP.
DN.
DR.
DS.
DWG.
C.I.P.
C.J.
C/L / ℄
CLG.
CLR.
C.M.U.
COL.
COMP.
CONC.
CONST.
CONT.
COORD.
CORR.
CPT.
CT.
BD.
BLDG.
BM.
B.O
BRG.
ACC.
A.C.T.
ADD.
ADJ.
A.F.F.
ALT.
APPROX.
ARCH.
AVG.
EA.
E.I.F.S.
E.J.
ELEC.
ELEV.
ENTR.
EQ.
EQUIP.
EXP.
EXIST.
ACCORDING/ACCORDION
ACOUSTICAL CEILING TILE
ADDENDUM
ADJUSTABLE/ADJACENT
ABOVE FINISHED FLOOR
ALTERNATE/ALTERATION
APPROXIMATE
ARCHITECT/ARCHITECTURAL
AVERAGE
BOARD
BUILDING
BEAM
BOTTOM OF
BEARING
DOUBLE
DEPARTMENT
DETAIL
DRINKING FOUNTAIN
DIAMETER
DIAGONAL
DIMENSION
DISPOSAL
DOWN
DOOR
DOWNSPOUT
DRAWING
EACH
EXTERIOR INSUL. FINISH SYSTEM
EXPANSION JOINT
ELECTRICAL
ELEVATOR / ELEVATION
ENTRANCE
EQUAL
EQUIPMENT
EXPANSION
EXISTING
CAST IRON PIPE/CAST IN PLACE
CONTROL JOINT
CENTER-LINE
CEILING
CLEAR
CONCRETE MASONRY UNITS
COLUMN
COMPOSITE/COMPOSITION
CONCRETE
CONSTRUCTION
CONTINUOUS
COORDINATE
CORRIDOR
CARPET
CERAMIC TILE
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISH FLOOR ELEVATION
FLOOR
FACE OF
FIBERGLASS REINFORCED PANEL
FOOT OR FEET
FOOTING
FURNACE/FURNISH
FIELD VERIFY
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GYPSUM BOARD
HOLLOW CORE
HANDICAP
HEADER
HARDWOOD
HARDWARE
HOLLOW METAL
HORIZONTAL
HOUR
HEIGHT
INSIDE DIMENSION
INCHES
INFORMATION
INSULATION
INTERIOR
LAMINATED
LAVATORY
LINEAL FOOT
KITCHEN
JANITOR
MAINTENANCE/MAINTAIN
MATERIAL
MAXIMUM
MECHANICAL
MEMBRANE
MEZZANINE
MANUFACTURER
MINIMUM/MINUTE
MIRROR
MISCELLANEOUS
MASONRY OPENING
MOUNTED
METAL
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
ON CENTER
OVERFLOW DRAIN
OVERHEAD DOOR
OPENING
OPPOSITE
ORIENTED STRAND BOARD
PRECAST
PERFORATED
PLASTIC LAMINATE
PLYWOOD
ROOF DRAIN
REINFORCING BAR
REFERENCE/REFRIGERATOR
REINFORCED
REQUIRED
REVISION/REVERSE
ROOM
ROUGH OPENING
SCHEDULE
SECTION
SQUARE FEET
SHEET
SHEATHING
SIMILAR
SIMILAR REVERSE
SPECIFICATION
STANDARD
STEEL
STORAGE
STRUCTURE/STRUCTURAL
SUSPENDED
SYMBOL
TONGUE AND GROOVE
TEMPERED/TEMPORARY/TEMPERATURE
THICK
TOP OF
TELEVISION
TYPICAL
UNDERWRITERS LABORATORIES, INC.
UNFINISHED
UNLESS NOTED OTHERWISE
VARIES
VINYL-COMPOSITION TILE
WITHOUT
WATER CLOSET
WOOD
WINDOW
WEIGHT
WELDED WIRE FABRIC
WELDED WIRE MESH
O.F.C.I. OWNER FURNISHED
CONTRACTOR INSTALLED
GRAPHIC SYMBOLS
100A
ROOM TAG
Room Name
DOOR TAG
WINDOW TAG1t
WALL PARTITION TYPE
FIRE EXTINGUISHER CABINET
A101
SIM
F.E.C
F.E
ELEVATION NUMBER
SHEET NUMBER
BUILDING SECTION NUMBER
SHEET NUMBER
FIRE EXTINGUISHER CABINET
INTERIOR ELEVATION MARK
ELEVATION MARKER
A1.100
Ref
Ref
R e fR e f
XX
2h
A101
Ref
1Ref 1 Ref
Ref
Name Elevation
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
CONSTRUCTION DOCUMENT SET
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/03/26
A u to d e s k D o c s
/R P
S E lt o n
H ill s E
S W in d o w R e p la c e m e n t/
-0
R P
S E lt o n H ill s E
S W in d o w
R e p la c e m e n t (R rv t
/4 /2
:4
:0
A M
G0.00
JASON WOODHOUSE
44421 03/03/2026
COVER SHEET
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S E
LT
O
N H
IL
LS
E S
W
IN
D O
W R
E P
L A
C E
M E
N T
26-009
03/03/2026
TMD,LG
JW
RPS ELTON HILLS ES WINDOW
REPLACEMENT
ROCHESTER MINNESOTA
PLANS ISSUED:03/03/2026
1-GENERAL INFORMATION
G0.00 COVER SHEET
2-ARCHITECTURAL DEMO
AD1.01 DEMO PLAN
AD1.21 DEMO REFLECTED CEILING PLAN
AD2.00 DEMO EXTERIOR ELEVATIONS
AD2.01 DEMO ENLARGED EXTERIOR ELEVATIONS
3-ARCHITECTURAL
A1.01 FLOOR PLAN
A1.21 REFLECTED CEILING PLAN
A2.00 EXTERIOR ELEVATIONS
A2.01 ENLARGED EXTERIOR ELEVATIONS
A4.10 DETAILS
A4.11 PARTIAL EXISTING PHOTO REFRENCE
4-MECHANICAL
M0 MECHANICAL SYMBOLS AND ABBREVIATIONS
M1 MECHANICAL PLANS
5-ELECTRICAL
E0 ELECTRICAL SYMBOLS AND ABBREVIATIONS
ED1 ELECTRICAL DEMOLITION PLAN
E1 ELECTRICAL PLAN
E2 ELECTRICAL PHOTOS
CODE INFORMATION: SHEET INDEXSITE LOCATION MAP
2020 MINNESOTA STATE BUILDING CODE
2020 MINNESOTA ACCESSIBILITY CODE
2024 MINNESOTA ENERGY CODE
PROPOSED PROJECT SUMMARY:
THE PROJECTS CONSIST OF REPLACING THE EXISTING EXTERIOR WINDOW SYSTEMS.
INSTALLING NEW EXTERIOR INSULATED STOREFRONT SYSTEMS.
WORK INCLUDES GENERAL, MECHANICAL AND ELECTRICAL SCOPE.
(NO ADDITIONAL BUILDING SQUARE FOOTAGE ADDED, CHANGE IN EXISTING BUILDING
SEPARATIONS AND MODIFICATIONS MADE TO EXISTING PARTITION RATINGS WITHIN THIS
PROJECT SCOPE)
OCCUPANCY CLASSIFICATION (CHAPTER 3):
GROUP E - EDUCATION (UNCHANGED)
TYPE OF CONSTRUCTION (CHAPTER 6):
TYPE II-B CONSTRUCTION, FULL SPRINKLERED (UNCHANGED)
2024 MINNESOTA ENERGY CODE
TABLE 5.5-6 BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 6
NEW EXTERIOR WALLS:
NON-RESIDENTIAL, INSULATION MIN. R-VALUE: R-13 + 12.5 C.I.
THE PROJECT CONSISTS OF THE REPLACEMENT OF AN EXISTING CURTAIN WALL SYSTEM
WITH NEW THERMALLY BROKEN INSULATED STOREFRONT WINDOW SYSTEM.
NO. REVISIONS DATE
DN
S B
S B
S B
DEMOLITION NOTES:
GENERAL DEMOLITION NOTES:
1. DASHED LINES REPRESENT EXISTING ITEMS TO BE REMOVED. U.N.O.
2. PROVIDE ALL WORK TO COMPLETE DEMOLITION AS MAY BE REQUIRED
TO ACCOMPLISH WORK AS SHOWN ON THE DRAWINGS UNLESS NOTED
OTHERWISE. ALL AS INDICATED OR REQUIRED RELATING TO THE
EXISTING BUILDING AND NOT OTHERWISE ASSIGNED IS INCLUDED
UNDER THE RESPONSIBILITY OF THE CONTRACTOR.
3. CONTRACTOR TO VERIFY EXISTING ELECTRICAL & PLUMBING
LOCATIONS PRIOR TO DEMOLITION. EXISTING PLUMBING AND
ELECTRICAL MAY REQUIRE MODIFICATION TO ACCOMPLISH THE NEW
DESIGN AS SHOWN ON THESE PLANS.
4. MECHANICAL, ELECTRICAL AND PLUMBING CONTRACTORS SHALL
TERMINATE ALL APPROPRIATE SERVICES TO EXISTING CONSTRUCTION
WHICH ARE TO BE PERMANENTLY DISCONNECTED. THEY SHALL
FURTHER MAKE ALL TEMPORARY SERVICE TERMINATIONS INDICATED
OR REQUIRED TO ACCOMPLISH THE DEMOLITION AND/OR NEW REVISED
OR REPLACED SERVICES AS PART OF WORK UNDER ALL CONTRACTS.
ALL PERMANENT TERMINATIONS SHALL BE REMOVED BACK TO THE
SOURCE. NO VACANT SERVICES SHALL BE LEFT IN PLACE.
5. CONTRACTORS ARE TO BE RESPONSIBLE FOR REMOVING AND HAULING
OF ALL DEMOLITION DEBRIS.
6. AT CONCLUSION OF DEMOLITION, ALL SURFACES SHALL BE READY TO
RECEIVE NEW FINISHES.
7. OWNER TO REMOVE/ RELOCATE FURNITURE, FIXTURES AND
EQUIPMENT, WITHIN CONSTRUCTION LIMITS, PRIOR TO START OF
CONSTRUCTION, COORDINATE PROJECT SCHEDULE WITH GENERAL
CONTRACTOR.
8. GENERAL CONTRACTOR IS RESPONSIBLE FOR EXISTING CONDITIONS
AND COORD. OF DRAWING INTENT. G.C. TO VERIFY EXISTING
CONDITIONS AND COORD. WITH ARCHITECT / ENGINEER TO ADJUST
PLANS FOR UNFORESEEN ISSUES. THE G.C. MUST ENSURE THE
DESIGN IS BUILDABLE WITH PRACTICAL MEANS AND METHODS,
FLAGGING ANY IMPRACTICAL ELEMENTS BEFORE CONSTRUCTION.
9. REMOVE AND SALVAGE ANY LOOSE BRICKS ALONG TOP OF WALLS FOR
SECURE REINSTALLATION PRIOR TO NEW BACKER ROD AND SEALANT.
1 REMOVE EXISTING STOREFRONT WINDOW IN ITS ENTIRETY AND
DISPOSE OF PROPERLY.
2 REMOVE EXISTING DOOR IN ITS ENTIRETY AND DISPOSE OF
PROPERLY. SALVAGE ALL EXISTING ELECTRONIC DOOR
HARDWARE AND SECURITY SYSTEM FOR REINSTALLATION.
(NOT ALL DEMOLITION NOTES APPEAR ON EVERY SHEET)
3 REMOVE EXISTING LOUVER IN ITS ENTIRETY AND DISPOSE OF
PROPERLY. SALVAGE EXISTING DAMPER FOR REINSTALLATION,
SEE MECH.
4 REMOVE EXISTING DOOR WEATHERSTIPPING AND DOOR SWEEP.
5 REMOVE EXISTING BLUE TRANSOM PANEL AND TRANSOM TOP
FRAME.
6 REMOVE EXISTING BLUE PANEL AND TRANSOM FRAME.
7 REMOVE EXISTING TRANSOM BLUE PANELS.
8 REMOVE EXISTING EXPOSED CONDUIT FOR PHOTO CELL DEVICE.
9 SALVAGE EXISTING METAL SILL CORNER GUARD FOR
REINSTALLLATION.
AD2.00
AD2.00
AD2.00
AD2.00
1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1
1 3
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/03/26
A u to d e s k D o c s
/R P
S E lt o n
H ill s E
S W in d o w R e p la c e m e n t/
-0
R P
S E lt o n H ill s E
S W in d o w
R e p la c e m e n t (R rv t
/4 /2
:5
:5
A M
AD1.01
JASON WOODHOUSE
44421 03/03/2026
DEMO PLAN
R O
C H
E S
T E
R
M
IN
N
E S
O T
A
R P
S E
L T
O N
H
IL
L S
E S
W
IN
D O
W R
E P
L A
C E
M E
N T
26-009
03/03/2026
TMD,LG
JW
3/32" = 1'-0"
LEVEL 1 - DEMOLITION FLOOR PLAN NORTH
1 1 1 1 1 1 1 1 1 11 1 1 1 1
1111111111111
2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 2 2 2 2 2 2 2 2 2 2 2 2
DEMOLITION CEILING NOTES:
2 REMOVE EXISTING WINDOW SHADE AND DISPOSE OF PROPERLY.
(NOT ALL DEMOLITION NOTES APPEAR ON EVERY SHEET)
1 REMOVE EXISTING CEILING TILE AND GRID FOR INSTALLATION OF
NEW WINDOW SCOPE.
3 REMOVE EXISTING FIBERGLASS SCREEN AND DISPOSE OF
PROPERLY.
GENERAL DEMOLITION NOTES:
1. DASHED LINES REPRESENT EXISTING ITEMS TO BE REMOVED. U.N.O.
2. PROVIDE ALL WORK TO COMPLETE DEMOLITION AS MAY BE REQUIRED
TO ACCOMPLISH WORK AS SHOWN ON THE DRAWINGS UNLESS
NOTED OTHERWISE. ALL AS INDICATED OR REQUIRED RELATING TO
THE EXISTING BUILDING AND NOT OTHERWISE ASSIGNED IS INCLUDED
UNDER THE RESPONSIBILITY OF THE CONTRACTOR.
3. CONTRACTOR TO VERIFY EXISTING ELECTRICAL & PLUMBING
LOCATIONS PRIOR TO DEMOLITION. EXISTING PLUMBING AND
ELECTRICAL MAY REQUIRE MODIFICATION TO ACCOMPLISH THE NEW
DESIGN AS SHOWN ON THESE PLANS.
4. MECHANICAL, ELECTRICAL AND PLUMBING CONTRACTORS SHALL
TERMINATE ALL APPROPRIATE SERVICES TO EXISTING CONSTRUCTION
WHICH ARE TO BE PERMANENTLY DISCONNECTED. THEY SHALL
FURTHER MAKE ALL TEMPORARY SERVICE TERMINATIONS INDICATED
OR REQUIRED TO ACCOMPLISH THE DEMOLITION AND/OR NEW
REVISED OR REPLACED SERVICES AS PART OF WORK UNDER ALL
CONTRACTS. ALL PERMANENT TERMINATIONS SHALL BE REMOVED
BACK TO THE SOURCE. NO VACANT SERVICES SHALL BE LEFT IN
PLACE.
5. CONTRACTORS ARE TO BE RESPONSIBLE FOR REMOVING AND
HAULING OF ALL DEMOLITION DEBRIS.
6. AT CONCLUSION OF DEMOLITION, ALL SURFACES SHALL BE READY TO
RECEIVE NEW FINISHES.
7. OWNER TO REMOVE/ RELOCATE FURNITURE, FIXTURES AND
EQUIPMENT, WITHIN CONSTRUCTION LIMITS, PRIOR TO START OF
CONSTRUCTION, COORDINATE PROJECT SCHEDULE WITH GENERAL
CONTRACTOR.
8. GENERAL CONTRACTOR IS RESPONSIBLE FOR EXISTING CONDITIONS
AND COORD. OF DRAWING INTENT. G.C. TO VERIFY EXISTING
CONDITIONS AND COORD. WITH ARCHITECT / ENGINEER TO ADJUST
PLANS FOR UNFORESEEN ISSUES. THE G.C. MUST ENSURE THE
DESIGN IS BUILDABLE WITH PRACTICAL MEANS AND METHODS,
FLAGGING ANY IMPRACTICAL ELEMENTS BEFORE CONSTRUCTION.
4 REMOVE PORTION OF EXISTING SOFFIT AT EXISTING JOINT FROM
A PREVIOUSLY DEMO.
5 REMOVE EXISTING EXPOSED CONDUIT FOR PHOTO CELL DEVICE
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/03/26
A u to d e s k D o c s
/R P
S E lt o n
H ill s E
S W in d o w R e p la c e m e n t/
-0
R P
S E lt o n H ill s E
S W in d o w
R e p la c e m e n t (R rv t
/4 /2
:5
:5
A M
AD1.21
JASON WOODHOUSE
44421 03/03/2026
DEMO REFLECTED CEILING
PLAN
R O
C H
E S
T E
R
M
IN
N
E S
O T
A
R P
S E
L T
O N
H
IL
L S
E S
W
IN
D O
W R
E P
L A
C E
M E
N T
26-009
03/03/2026
TMD,LG
JW
3/32" = 1'-0"
LEVEL 1 - REFLECTED CEILING PLAN DEMO
NORTH
LEVEL 1
100' - 0"
B.O.ROOF
112' - 0"
Level 1A Top of Joists 110' - 0"
Level 3 top of gym 119' - 4"
AD2.01
1 ___________________
AD2.01
AD2.01
AD2.01
6 5
LEVEL 1
100' - 0"
B.O.ROOF
112' - 0"
Level 1A Top of Joists 110' - 0"
Level 3 top of gym 119' - 4"
AD2.01
7 7
4 4
LEVEL 1
100' - 0"
B.O.ROOF
112' - 0"
Level 1A Top of Joists 110' - 0"
Level 3 top of gym 119' - 4"
LEVEL 1
100' - 0"
B.O.ROOF
112' - 0"
Level 1A Top of Joists 110' - 0"
Level 3 top of gym 119' - 4"
AD2.01
DEMOLITION NOTES:
GENERAL DEMOLITION NOTES:
1. DASHED LINES REPRESENT EXISTING ITEMS TO BE REMOVED. U.N.O.
2. PROVIDE ALL WORK TO COMPLETE DEMOLITION AS MAY BE REQUIRED
TO ACCOMPLISH WORK AS SHOWN ON THE DRAWINGS UNLESS NOTED
OTHERWISE. ALL AS INDICATED OR REQUIRED RELATING TO THE
EXISTING BUILDING AND NOT OTHERWISE ASSIGNED IS INCLUDED
UNDER THE RESPONSIBILITY OF THE CONTRACTOR.
3. CONTRACTOR TO VERIFY EXISTING ELECTRICAL & PLUMBING
LOCATIONS PRIOR TO DEMOLITION. EXISTING PLUMBING AND
ELECTRICAL MAY REQUIRE MODIFICATION TO ACCOMPLISH THE NEW
DESIGN AS SHOWN ON THESE PLANS.
4. MECHANICAL, ELECTRICAL AND PLUMBING CONTRACTORS SHALL
TERMINATE ALL APPROPRIATE SERVICES TO EXISTING CONSTRUCTION
WHICH ARE TO BE PERMANENTLY DISCONNECTED. THEY SHALL
FURTHER MAKE ALL TEMPORARY SERVICE TERMINATIONS INDICATED
OR REQUIRED TO ACCOMPLISH THE DEMOLITION AND/OR NEW REVISED
OR REPLACED SERVICES AS PART OF WORK UNDER ALL CONTRACTS.
ALL PERMANENT TERMINATIONS SHALL BE REMOVED BACK TO THE
SOURCE. NO VACANT SERVICES SHALL BE LEFT IN PLACE.
5. CONTRACTORS ARE TO BE RESPONSIBLE FOR REMOVING AND HAULING
OF ALL DEMOLITION DEBRIS.
6. AT CONCLUSION OF DEMOLITION, ALL SURFACES SHALL BE READY TO
RECEIVE NEW FINISHES.
7. OWNER TO REMOVE/ RELOCATE FURNITURE, FIXTURES AND
EQUIPMENT, WITHIN CONSTRUCTION LIMITS, PRIOR TO START OF
CONSTRUCTION, COORDINATE PROJECT SCHEDULE WITH GENERAL
CONTRACTOR.
8. GENERAL CONTRACTOR IS RESPONSIBLE FOR EXISTING CONDITIONS
AND COORD. OF DRAWING INTENT. G.C. TO VERIFY EXISTING
CONDITIONS AND COORD. WITH ARCHITECT / ENGINEER TO ADJUST
PLANS FOR UNFORESEEN ISSUES. THE G.C. MUST ENSURE THE
DESIGN IS BUILDABLE WITH PRACTICAL MEANS AND METHODS,
FLAGGING ANY IMPRACTICAL ELEMENTS BEFORE CONSTRUCTION.
9. REMOVE AND SALVAGE ANY LOOSE BRICKS ALONG TOP OF WALLS FOR
SECURE REINSTALLATION PRIOR TO NEW BACKER ROD AND SEALANT.
1 REMOVE EXISTING STOREFRONT WINDOW IN ITS ENTIRETY AND
DISPOSE OF PROPERLY.
2 REMOVE EXISTING DOOR IN ITS ENTIRETY AND DISPOSE OF
PROPERLY. SALVAGE ALL EXISTING ELECTRONIC DOOR
HARDWARE AND SECURITY SYSTEM FOR REINSTALLATION.
(NOT ALL DEMOLITION NOTES APPEAR ON EVERY SHEET)
3 REMOVE EXISTING LOUVER IN ITS ENTIRETY AND DISPOSE OF
PROPERLY. SALVAGE EXISTING DAMPER FOR REINSTALLATION,
SEE MECH.
4 REMOVE EXISTING DOOR WEATHERSTIPPING AND DOOR SWEEP.
5 REMOVE EXISTING BLUE TRANSOM PANEL AND TRANSOM TOP
FRAME.
6 REMOVE EXISTING BLUE PANEL AND TRANSOM FRAME.
7 REMOVE EXISTING TRANSOM BLUE PANELS.
8 REMOVE EXISTING EXPOSED CONDUIT FOR PHOTO CELL DEVICE.
9 SALVAGE EXISTING METAL SILL CORNER GUARD FOR
REINSTALLLATION.
3/32" = 1'-0"
DEMO WEST ELEVATION
1/8" = 1'-0"
DEMO NORTH ELEVATION
3/32" = 1'-0"
DEMO EAST ELEVATION
1/8" = 1'-0"
DEMO SOUTH ELEVATION SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/03/26
A u to d e s k D o c s
/R P
S E lt o n
H ill s E
S W in d o w R e p la c e m e n t/
-0
R P
S E lt o n H ill s E
S W in d o w
R e p la c e m e n t (R rv t
/4 /2
:5
:0
A M
AD2.00
JASON WOODHOUSE
44421 03/03/2026
DEMO EXTERIOR
ELEVATIONS
R O
C H
E S
T E
R
M
IN
N
E S
O T
A
R P
S E
L T
O N
H
IL
L S
E S
W
IN
D O
W R
E P
L A
C E
M E
N T
26-009
03/03/2026
TMD,LG
JW
26' - 0"
V .I .F
23' - 10"
V .I
.F
6' - 4"13' - 4"6' - 4"
A4.10
26' - 0"
V .I
.F
26' - 0"
V .I
.F
V .I
.F
25' - 9"
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/03/26
A u to d e s k D o c s
/R P
S E lt o n
H ill s E
S W in d o w R e p la c e m e n t/
-0
R P
S E lt o n H ill s E
S W in d o w
R e p la c e m e n t (R rv t
/4 /2
:5
:0
A M
AD2.01
JASON WOODHOUSE
44421 03/03/2026
DEMO ENLARGED EXTERIOR
ELEVATIONS
R O
C H
E S
T E
R
M
IN
N
E S
O T
A
R P
S E
L T
O N
H
IL
L S
E S
W
IN
D O
W R
E P
L A
C E
M E
N T
26-009
03/03/2026
TMD,LG
JW
1/2" = 1'-0"
DEMO PANEL A
1/2" = 1'-0"
DEMO PANEL B
1/2" = 1'-0"
DEMO PANEL C
1/2" = 1'-0"
DEMO PANEL D
1/2" = 1'-0"
DEMO PANEL E
1/2" = 1'-0"
DEMO PANEL F
B
S B
S B
1. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH ALL
REQUIREMENTS OF THE OWNER. EACH TRADE CONTRACTOR SHALL BE
RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL
SAFETY PROCEDURES, PRECAUTIONS AND PROGRAMS IN CONNECTION
WITH THEIR WORK.
2. THE GENERAL CONTRACTOR SHALL FILE FOR AND OBTAIN ALL REQUIRED
PERMITS, LETTERS OF SATISFACTORY COMPLETION AND CERTIFICATES
OF OCCUPANCY FROM THE LOCAL BUILDING OFFICIALS.
3. ALL EQUIPMENT SHOWN AS DASHED IS BY THE OWNER. ELECTRICAL
CONTRACTOR TO VERIFY POWER REQUIREMENTS FOR OWNER'S
EQUIPMENT. MECHANICAL CONTRACTOR TO VERIFY PLUMBING AND
HVAC REQUIREMENTS OF OWNER'S EQUIP.
4. REFER TO THE MECHANICAL, ELECTRICAL DRAWINGS FOR ADDITIONAL
WORK REQUIRED UNDER THIS CONTRACT.
5. THE GENERAL CONTRACTOR AND/OR MECHANICAL CONTRACTOR SHALL
COORDINATE ALL MECHANICAL WORK WITH THE OWNER'S
REPRESENTATIVE AND ALL OTHER TRADES.
6. THE GENERAL CONTRACTOR AND/OR ELECTRICAL CONTRACTOR SHALL
COORDINATE ALL ELECTRICAL WORK WITH THE OWNER'S
REPRESENTATIVE AND ALL OTHER TRADES.
GENERAL NOTES:
FLOOR PLAN NOTES:
1 NEW STOREFRONT WINDOW WITH INSULATED PANEL.
2 PATCH EXISTING CONCRETE SLAB EDGE
3 NEW LOUVER WITH REINSTALLED DAMPER, SEE MECH.
FOR SCOPE.
4 REPAIR EXISTING HARDCOAT STUCCO TO MATCH
ADJACENT SOFFIT COLOR AND TEXTURE
A2.00
A2.00
A2.00
A2.00
1 11 1 1 1 1 1 1 1
1111111111111
A4.10
A4.10
11 3
A4.10
101 102
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/03/26
A u to d e s k D o c s
/R P
S E lt o n
H ill s E
S W in d o w R e p la c e m e n t/
-0
R P
S E lt o n H ill s E
S W in d o w
R e p la c e m e n t (R rv t
/4 /2
:4
:1
A M
A1.01
JASON WOODHOUSE
44421 03/03/2026
FLOOR PLAN
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S E
LT
O
N H
IL
LS
E S
W
IN
D O
W R
E P
L A
C E
M E
N T
26-009
03/03/2026
TMD,LG
JW
3/32" = 1'-0"
LEVEL 1 - FLOOR PLAN NORTH
1. MECHANICAL AND ELECTRICAL INFORMATION SHOWN IS INTENDED ONLY TO
COMMUNICATE DESIGN INTENT. REFER TO MECHANICAL AND ELECTRICAL
DRAWINGS FOR DETAILED INFORMATION. NOTIFY ARCHITECT/ENGINEER OF ANY
DISCREPANCIES NOTED PRIOR TO COMMENCEMENT OF WORK.
2. COORDINATE ALL CEILING MOUNTED EQUIPMENT SUPPORTS, DEVICE LOCATIONS,
CLEARANCES, ETC. WITH EQUIPMENT INSTALLERS AND SUPPLIERS PRIOR TO
INSTALLATION.
3. ACOUSTICAL PANEL CEILING GRIDS OR PANELS SHALL BE CENTERED IN ROOMS
UNLESS OTHERWISE NOTED OR DIMENSIONED.
4. ALL CEILING MOUNTED ITEMS (LIGHT FIXTURES, SPRINKLER HEADS, SPEAKERS,
ETC.) SHALL BE CENTERED IN ACOUSTICAL CEILING PANELS OR GYPSUM BOARD
SOFFITS UNLESS OTHERWISE NOTED OR DIMENSIONED.
5. SPACE LIGHT FIXTURES EVENLY IN ROOMS, BAYS, SPACES, ETC. AND CENTER
BETWEEN EXPOSED STRUCTURAL ELEMENTS WHERE APPROPRIATE.
6. DIMENSIONS TO CEILING-INSTALLED ITEMS ARE TO CENTERLINE OF FIXTURE OR
EQUIPMENT UNLESS NOTED OTHERWISE.
7. LOCATE CONTROL JOINTS IN GYPSUM BOARD CEILINGS, SOFFITS, BULKHEADS,
AND FASCIAS AS INDICATED ON DRAWINGS OR AS SPECIFIED AND TO ALIGN WITH
THOSE IN WALLS BELOW. VERIFY PROPOSED LAYOUT WITH ARCHITECT PRIOR TO
INSTALLATION.
8. PAINT ALL CONDUITS, DUCTWORK, SUPPORTS, HANGERS, ETC. THAT WILL REMAIN
EXPOSED TO VIEW. MATCH COLOR INDICATED FOR STRUCTURE UNLESS NOTED
OTHERWISE.
GENERAL CEILING NOTES:
ACOUSTICAL CEILING TILE (ACT-1)
CEILING TYPES LEGEND
CEILING PLAN NOTES:
2 PATCH HARD COAT STUCCO MATCHING EXISTING CONSTRUCTION AND
FINISH.
1 REINSTALL MODIFIED CEILING TILE AND GRID TO ALIGN WITH VERTICAL
MECH. PANEL.
3 NEW CONTINUOUS SOFFIT VENT.
1 1 1 1 1 1 1 1 11 1
1111111111111
A4.10
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/03/26
A u to d e s k D o c s
/R P
S E lt o n
H ill s E
S W in d o w R e p la c e m e n t/
-0
R P
S E lt o n H ill s E
S W in d o w
R e p la c e m e n t (R rv t
/4 /2
:4
:1
A M
A1.21
JASON WOODHOUSE
44421 03/03/2026
REFLECTED CEILING PLAN
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S E
LT
O
N H
IL
LS
E S
W
IN
D O
W R
E P
L A
C E
M E
N T
26-009
03/03/2026
TMD,LG
JW
3/32" = 1'-0"
LEVEL 1 - REFLECTED CEILING PLAN NORTH
LEVEL 1
100' - 0"
B.O.ROOF
112' - 0"
Level 1 Finished Floor 100' - 0"
Level 1A Top of Joists 110' - 0"
Level 3 top of gym 119' - 4"
W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1W32
A4.10
W5
5 6
LEVEL 1
100' - 0"
B.O.ROOF
112' - 0"
Level 1A Top of Joists 110' - 0"
Level 3 top of gym 119' - 4"
W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W11
LEVEL 1
100' - 0"
B.O.ROOF
112' - 0"
Level 1 Finished Floor 100' - 0"
Level 1A Top of Joists 110' - 0"
Level 3 top of gym 119' - 4"
W2 W2
LEVEL 1
100' - 0"
B.O.ROOF
112' - 0"
Level 1 Finished Floor 100' - 0"
Level 1A Top of Joists 110' - 0"
Level 3 top of gym 119' - 4"
W43
1 CAULK AROUND EXISTING DOOR FRAME.
ELEVATION NOTES:
GENERAL REPAIR NOTES:
1. ALL SURFACE-MOUNTED FIXTURES AND ACCESSORIES
(LIGHTING, SPEAKERS, ETC.) REMOVED DURING
CONSTRUCTION ARE TO BE REINSTALLED IN THEIR
ORIGINAL LOCATION AT THE COMPLETION OF WORK
TO THAT AREA.
2. PROVIDE BACKER ROD AND SEALANT MISSING AT
STUCCO, BRICK AND ALUM. DOOR / WINDOW FRAMES.
3. PROVIDE NEW SEALANT AT FAILED SEALANT JOINTS
OF EXISTING TO REMAIN ALUM. DOOR / WINDOW
FRAMES.
4. NEW DOOR WEATHERSTRIPPING AND DOOR SWEEP AT
EXISTING ALUM. DOORS TO REMAIN.
2 NEW LOUVER WITH REINSTALLED DAMPER, SEE
MECH. FOR SCOPE.
3 REPAIR EXISTING HARDCOAT STUCCO TO
MATCH ADJACENT WALL COLOR AND TEXTURE
4 FABRICATED INSULATED ACM PANEL AND
BONDED INSULATION PANEL
5 NEW BLUE TRANSOM PANEL AND NEW
TRANSOM TOP FRAME.
6 INSTALL SALVAGED EXISTING METAL SILL
CORNER GUARD WITH NEW S.S. FASTENER.
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/03/26
A u to d e s k D o c s
/R P
S E lt o n
H ill s E
S W in d o w R e p la c e m e n t/
-0
R P
S E lt o n H ill s E
S W in d o w
R e p la c e m e n t (R rv t
/4 /2
:4
:2
A M
A2.00
JASON WOODHOUSE
44421 03/03/2026
EXTERIOR ELEVATIONS
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S E
LT
O
N H
IL
LS
E S
W
IN
D O
W R
E P
L A
C E
M E
N T
26-009
03/03/2026
TMD,LG
JW
3/32" = 1'-0"
WEST ELEVATION
3/32" = 1'-0"
EAST ELEVATION
1/8" = 1'-0"
NORTH ELEVATION
1/8" = 1'-0"
SOUTH ELEVATION
26' - 0" - F.V.
6' - 6" 6' - 6" 6' - 6" 6' - 6" V
.I .F
/8
/8
F
.V
/8
/8
5' - 11" 6' - 0" 6' - 0" 5' - 11"
23' - 10" - F.V.
/8
/8
F
.V
V .I
.F
A4.10
6' - 4" 4' - 5" 4' - 6" 4' - 5" 6' - 4"
F
.V
26' - 0" - F.V.
25' - 9" - F.V.
4' - 4" 4' - 4" 4' - 2 1/2" 4' - 2 1/2" 4' - 4" 4' - 4"
F
.V
V .I
.F
V .I
.F
/8
17' - 4" - F.V.
4' - 4" 4' - 4" 4' - 4" 4' - 4"
4' - 2"
/8
F
.V
/8
1 CAULK AROUND EXISTING DOOR FRAME.
ELEVATION NOTES:
GENERAL REPAIR NOTES:
1. ALL SURFACE-MOUNTED FIXTURES AND ACCESSORIES
(LIGHTING, SPEAKERS, ETC.) REMOVED DURING
CONSTRUCTION ARE TO BE REINSTALLED IN THEIR
ORIGINAL LOCATION AT THE COMPLETION OF WORK
TO THAT AREA.
2. PROVIDE BACKER ROD AND SEALANT MISSING AT
STUCCO, BRICK AND ALUM. DOOR / WINDOW FRAMES.
3. PROVIDE NEW SEALANT AT FAILED SEALANT JOINTS
OF EXISTING TO REMAIN ALUM. DOOR / WINDOW
FRAMES.
4. NEW DOOR WEATHERSTRIPPING AND DOOR SWEEP AT
EXISTING ALUM. DOORS TO REMAIN.
2 NEW LOUVER WITH REINSTALLED DAMPER, SEE
MECH. FOR SCOPE.
3 REPAIR EXISTING HARDCOAT STUCCO TO
MATCH ADJACENT WALL COLOR AND TEXTURE
4 FABRICATED INSULATED ACM PANEL AND
BONDED INSULATION PANEL
5 NEW BLUE TRANSOM PANEL AND NEW
TRANSOM TOP FRAME.
6 INSTALL SALVAGED EXISTING METAL SILL
CORNER GUARD WITH NEW S.S. FASTENER.
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/03/26
A u to d e s k D o c s
/R P
S E lt o n
H ill s E
S W in d o w R e p la c e m e n t/
-0
R P
S E lt o n H ill s E
S W in d o w
R e p la c e m e n t (R rv t
/4 /2
:4
:2
A M
A2.01
JASON WOODHOUSE
44421 03/03/2026
ENLARGED EXTERIOR
ELEVATIONS
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S E
LT
O
N H
IL
LS
E S
W
IN
D O
W R
E P
L A
C E
M E
N T
26-009
03/03/2026
TMD,LG
JW
1/2" = 1'-0"
W1 1/2" = 1'-0"
W2
1/2" = 1'-0"
W3 1/2" = 1'-0"
W4
1/2" = 1'-0"
W5
EXISTING MECHANICAL UNIT TO REMAIN
EXISTING WALL ASSEMBLY TO REMAIN
EXISTING MASONRY CAP TO REMAIN
CONT. SEALANT
1" INSULATED THERMALLY BROKEN
STOREFRONT WINDOW SYSTEM
PREFINISHED ALUM. BREAK METAL
SLOPE SILL
BACKER ROD AND SEALANT
CONTINUOUS NEOPRENE
GASKET BETWEEN WINDOW
AND FRAME CLOSURE
EXTERIOR WINDOW SYSTEM
PRE-FINISHED ALUM.
CLOSURE WITH HEMMED
EDGES TO MATCH WINDOW
SYSTEM - MECHANICALLY
ATTACH TO WINDOW MULLION
FALSE WINDOW MULLION
CENTERED ON EXISTING
INTERIOR PARTITION
BREAK METAL MULLION WITH
ACOUSTICAL INSULATION
CONTINUOUS SEALANT -
EACH SIDE OF WINDOW
FRAME
LINE OF WINDOW SILL BELOW
CONTINUOUS NEOPRENE
GASKET BETWEEN WINDOW
AND FRAME CLOSURE
EXTERIOR WINDOW SYSTEM
PRE-FINISHED ALUM.
CLOSURE WITH HEMMED
EDGES TO MATCH WINDOW
SYSTEM - MECHANICALLY
ATTACH TO WINDOW MULLION
FALSE WINDOW MULLION
CENTERED ON EXISTING
INTERIOR PARTITION
BREAK METAL FALSE MULLION
WITH ACOUSTICAL
INSULATION
CONTINUOUS SEALANT -
EACH SIDE OF WINDOW
FRAME
LINE OF WINDOW SILL BELOW
MODIFIED CEILING TILE
REMOVE AND REINSTALL
EXISTING ALUM. CLOSER ANGLE.
NEW BACKER ROD AND SEALANT
WOOD BLOCKING
2 1/2" THICK FABRICATED
INSULATED ACM PANEL AND
BONDED INSULATION PANEL
HORZ. ROLLER SHADE
EXISTING BRICK BEYOND
EXISTING BAR JOIST
EXISTING SUPPORT / BLOCKING MAY VARY.
CONTRACTOR SHALL PROVIDE NEW
SUPPORTS AND BLOCKING AS NECESSARY
EXISTING ALUM. FASCIA TO REMAIN.
CONTRACTOR SHALL REPAIR / REPLACE
FASCIA THAT BECOMES DAMAGED DURING
CONSTRUCTION
F.V.
6 1/2"
/4
LINE OF VERTICAL EXISTING MECH.
ENCLOSURE PANEL BEYOND
CEILING GRID EDGE TRIM TO PROVIDE
FINISHED TRANSITION. ALIGN WITH
VERRTICAL EXISTING MECH.
ENCLOSURE PANEL BEYOND
1" INSULATED THERMALLY BROKEN
STOREFRONT WINDOW SYSTEM
1" INSULATED THERMALLY BROKEN
STOREFRONT WINDOW SYSTEM
F.V. ALUM. BREAK METAL AND
FINISHED ENDS SHADE POCKET
WITH HEMMED EDGES. COLOR TO
MATCH EXISTING CEILING GRID
3/4" PLYWOOD
PREFINISHED BRAKE METAL
FLASHING MATCH FASCIA COLOR
EXISTING FASCIA FLASHING
EXISTING ALUM. PLATE
V A
R
IE
S
EXISTING CANOPY ROOF STRUCTURE
SUSPENDED CANOPY CEILING TO MATCH
EXISTING WITH STUCCO FINISH
WOOD BLOCKING
5/8" EXTERIOR SHEATHING
CLASS 'A' CLOSED CELL SPRAY FOAM INSULATION
3 5/8" METAL STUD
5/8" GYPSUM BOARD
2 X 6 WOOD STUD
EXISTING BAR JOIST AND
STRUCTURE ABOVE
CEILING GRID EDGE TRIM TO
PROVIDE FINISHED TRANSION
NEW MODIFIED CEILING TO
MATCH EXISTING
EXTERIOR SEALANT
1" INSULATED THERMALLY BROKEN
STOREFRONT WINDOW SYSTEM
PREFINISHED ALUM. FLASHING
BACKER ROD AND CONT. SEALANT
STUD BRACING, AS REQUIRED
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/03/26
A u to d e s k D o c s
/R P
S E lt o n
H ill s E
S W in d o w R e p la c e m e n t/
-0
R P
S E lt o n H ill s E
S W in d o w
R e p la c e m e n t (R rv t
/4 /2
:4
:2
A M
A4.10
JASON WOODHOUSE
44421 03/03/2026
DETAILS
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S E
LT
O
N H
IL
LS
E S
W
IN
D O
W R
E P
L A
C E
M E
N T
26-009
03/03/2026
TMD,LG
JW
3" = 1'-0"
TYPICAL WINDOW SILL DETAIL
1 1/2" = 1'-0"
CMU WALL AT WINDOW
1 1/2" = 1'-0"
INTERIOR PARTITION AT WINDOW
3" = 1'-0"
TYPICAL INSULATED PANEL HEAD DETAIL
3" = 1'-0"
CANOPY SECTION AT STOREFRONT
B
S B
S B
3 54
6 78
9 10
14 1312
18 19
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I
AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MINNESOTA.
© 2026 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/03/26
A u to d e s k D o c s
/R P
S E lt o n
H ill s E
S W in d o w R e p la c e m e n t/
-0
R P
S E lt o n H ill s E
S W in d o w
R e p la c e m e n t (R rv t
/4 /2
:4
:3
A M
A4.11
JASON WOODHOUSE
44421 03/03/2026
PARTIAL EXISTING PHOTO
REFRENCE
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S E
LT
O
N H
IL
LS
E S
W
IN
D O
W R
E P
L A
C E
M E
N T
26-009
03/03/2026
TMD,LG
JW
1 2 6
7 8 9 10
NO. REVISIONS DATE
14 15
17 - typical classroom
18 19 20
MECHANICAL SYMBOLS LEGEND
DESIGNATIONSSYMBOLDESIGNATIONSSYMBOLDESIGNATIONSSYMBOL DESIGNATIONSSYMBOL
PLUMBING
ACID VENT
ACID WASTE
DEIONIZED WATER SUPPLY
FILTERED WATER
DOMESTIC HOT WATER
DOMESTIC HOT WATER (TEMP. INDICATED)
DOMESTIC RECIRC. HOT WATER
HARD COLD WATER
OVERFLOW STORM DRAIN
REVERSE OSMOSIS WATER
SANITARY VENT
SANITARY WASTE
SOIL DRAINAGE TILE
SOFTENED COLD WATER
SOFTENED HOT WATER
TEMPERED WATER
STORM DRAIN
WELL WATER
AV
AW
DIS
HARD
SDT
RO
V
W
SOFT
SHW
TW
OSD
SD
WW
NPCW NON-POTABLE COLD WATER
NPHW NON-POTABLE HOT WATER
FW
HW
RHW
GW GREASE WASTE
DOMESTIC COLD WATERCW
CLEAR WATER VENTCWV
CLEAR WATER WASTECWW
DOM. RECIRC. HOT WATER (TEMP. INDICATED)140 RHW
PUMPED ACID WASTEPAW
PUMPED STORMPSD
PUMPED WASTEPW
COMPRESSED AIR (PSI INDICATED)10#A
MECHANICAL PIPING
BOILER FEED
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CONDENSATE DRAIN
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
FUEL OIL SUPPLY
FUEL OIL RETURN
FUEL OIL VENT
FUEL OIL FILL
GLYCOL SUPPLY
GLYCOL RETURN
HEAT RECOVERY SUPPLY
HEAT RECOVERY RETURN
HEATING WATER SUPPLY
HEATING WATER RETURN
LIQUIFIED PETROLEUM GAS
NATURAL GAS (PSI INDICATED)
PUMPED CONDENSATE
RADIATION WATER SUPPLY
RADIATION WATER RETURN
REFRIGERANT LIQUID
BF
CWS
CWR
CD
FOS
GS
GR
HRS
HRR
HWR
HWS
LPG
2#G
FOF
PC
RADS
CS
CR
FOR
FOV
RADR
RL
REFRIGERANT SUCTION
REFRIGERANT HOT GAS BYPASS
REHEAT WATER SUPPLY
REHEAT WATER RETURN
REMOTE RADIATOR SUPPLY
REMOTE RADIATOR RETURN
SECONDARY HEATING WATER SUPPLY
SECONDARY HEATING WATER RETURN
SNOW MELT SUPPLY
SNOW MELT RETURN
STEAM SUPPLY (PSI INDICATED)
STEAM CONDENSATE (PSI INDICATED)
RRS
RS
RHG
RHR
RHS
RRR
SHWS
SHWR
SMS
SMR
10#STM
10#SC
PIPE FITTINGS
ELBOW DOWN
PIPE CAP
ELBOW UP
TEE, OUTLET UP
TEE, OUTLET DOWN
CONNECTION, TOP
ECCENTRIC REDUCER
CONCENTRIC REDUCER
MEDICAL GAS
MEDICAL VACUUM
WASTE ANESTHETIC GAS DISPOSAL
CARBON DIOXIDE
OXYGEN
NITROGEN
NITROUS OXIDE
MEDICAL AIR
WAGD
CO2
O
N
MV
N2O
MA
PIPE UNION
PIPE FLANGE
ELBOW
TEE
FIRE PROTECTION
DFP
F FIRE PROTECTION
FIRE PROTECTION (DRY SYSTEM)
POST INDICATOR VALVE (PIV)
RECESSED FIRE DEPT CABINET
SURFACE MOUNTED FIRE DEPT CABINET
FIRE PROTECTION RISER
UPRIGHT SPRINKLER HEAD W/GUARD
PENDANT SPRINKLER HEAD
UPRIGHT SPRINKLER HEAD
SIDEWALL SPRINKLER HEAD
BUTTERFLY VALVE W/TAMPER SWITCH
DETECTOR CHECK W/BYPASS METER
GRADE FIRE DEPT CONNECTION
FLUSH FIRE DEPT CONNECTION
FIRE DEPT VALVE W/CAP AND CHAIN
O.S. & Y. VALVE W/TAMPER SWITCH
DRY PIPE VALVE
PREACTION VALVE
TS
FDVC
FDVC
FDV
TS
ANNOTATION
(4)A-12"ø
GRILLE, REGISTER, &
DIFFUSER IDENTIFICATION
QUANTITY
CFM
TYPE
SIZE
X X
X X
X X
X X
DETAIL NUMBER
SHEET NUMBER
SECTION NUMBER
SHEET NUMBER
EQUIP DESIGNATION
EQUIP NUMBER
POINT OF CONNECTION, NEW TO EXISTING
POINT OF DISCONNECTION
FTR/RP 01
6'-5"
0.5
HYDRONIC FINNED TUBE
RADIATION & RADIANT
PANEL IDENTIFICATION
TYPE ACTIVE
ELEMENT
LENGTHGPM
EBR 01
6'-5"
ELECTRIC BASEBOARD
RADIATION
IDENTIFICATION
ACTIVE
ELEMENT
LENGTH
ZONE VALVE BOXZVB
AREA ALARM PANELAAP
COMBINATION AREA/MASTER ALARM
PANEL
CAP
TYPE
INTERRUPTIBLE GASIG
PROCESS AND LABORATORY
LABORATORY AIR
LABORATORY VACUUM
ARGON
PROCESS WASTE
NITROGEN
HOUSE VACUUM
LV
AR
PRW
LA
N
HV
PROCESS VACUUMPV
INSTRUMENT AIRIA
ATMOSPHERIC STEAM SUPPLY
ATMOSPHERIC STEAM CONDENSATE
ATM STM
ATM SC
CONNECTION, BOTTOM
DARK DASHED LINE WEIGHT INDICATES
EXISTING ITEM TO BE DEMOLISHED.
GENERAL
LIGHT SOLID LINE WEIGHT INDICATES
EXISTING ITEM TO REMAIN.
DARK SOLID LINE WEIGHT INDICATES
NEW ITEM OR NEW LOCATION.
ROUND
12x12
12ø 12/12
RECTANGULAR (WxH)
FLAT-OVAL (W/H)
DUCT
DIMENSIONS
LIQUID NITROGENLN
MASTER ALARM PANELMAP
XXXX #-## EXISTING EQUIP NUMBER
EXISTING EQUIP DESIGNATION
MECHANICAL ABBREVIATIONS
AD AREA DRAIN
AFF ABOVE FINISHED FLOOR
AFMS AIR FLOW MEASURING STATION
AHU AIR HANDLING UNIT
ANB ACID NEUTRALIZING BASIN
AP ACCESS PANEL
ARCH ARCHITECT
AS AIR SEPARATOR
BD BUTTERFLY DAMPER
B/G BELOW GRADE
BTU BRITISH THERMAL UNIT
BWV BACKWATER VALVE
CCF HUNDRED CUBIC FEET
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CL CENTER LINE
CLG CEILING
CO CLEAN OUT
CONTR CONTRACTOR
CONV CONVECTOR
CUH CABINET UNIT HEATER
CW COLD WATER
DB DECIBEL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIFF DIFFUSER
DISCH DISCHARGE
DMPR DAMPER
DN DOWN
DR DRAIN
DSN DOWNSPOUT NOZZLE
DWG DRAWING
EAT ENTERING AIR TEMPERATURE
EDR EQUIVALENT DIRECT RADIATION
EP ELECTRIC-PNEUMATIC
EWC ELECTRIC WATER COOLER
EWT ENTERING WATER TEMPERATURE
EXH EXHAUST
EXP EXPANSION
F FAHRENHEIT
FC FAN COIL
FCO FLOOR CLEAN OUT
FD FLOOR DRAIN
FHC FIRE HOSE CABINET
FHR FIRE HOSE RACK
FLR FLOOR
FLEX FLEXIBLE
FM FIRE MAIN
FPM FEET PER MINUTE
FPS FEET PER SECOND
FT FEET OR FOOT
F&T FLOAT AND THERMOSTATIC
FTG FOOTING
FTR FINNED TUBE RADIATION
FV FACE VELOCITY
GA GAUGE
GAL GALLON
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HB HOSE BIBB
HD HEAD
HOA HANDS-OFF-AUTOMATIC
HTG HEATING
HTR HEATER
HVAC HEATING, VENTILATION,
AND AIR CONDITIONING
HYD HYDRANT
HW HOT WATER
GCO GRADE CLEANOUT
INSUL INSULATION
KW KILOWATT
LAT LEAVING AIR TEMPERATURE
LAV LAVATORY
LWT LEAVING WATER TEMPERATURE
MBH BTU PER HOUR (THOUSANDS)
MCF THOUSAND CUBIC FEET
MH MANHOLE
NC
NOISE CRITERIA OR
NORMALLY CLOSED
NEG NEGATIVE
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
OA OUTSIDE AIR
OBD OPPOSED BLADE DAMPER
ORD OVERFLOW ROOF DRAIN
PD PRESSURE DROP OR DIFFERENCE
PE PNEUMATIC-ELECTRIC
PLBG PLUMBING
PRV
PRESSURE REDUCING VALVE
OR POWER ROOF VENTILATOR
PSIA POUNDS/SQ INCH ABSOLUTE
PSIG POUNDS/SQ INCH GAUGE
PVC POLY VINYL CHLORIDE
RA RETURN AIR
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
RECIRC RECIRCULATING
REG REGISTER
RET RETURN
RH RELATIVE HUMIDITY
RHT REHEAT
RHC REHEAT COIL
RHW RECIRCULATED HOT WATER
RM ROOM
RPM REVOLUTIONS PER MINUTE
RPZ
REDUCED ZONE BACKFLOW
PREVENTER
SA SUPPLY AIR
SAN SANITARY
SCFM CFM, STANDARD CONDITIONS
SD SMOKE DAMPER
SP STATIC PRESSURE
SPECS SPECIFICATIONS
SUP SUPPLY
SQ SQUARE
STM STEAM
TD TEMPERATURE DIFFERENCE
TEMP TEMPERATURE
TONS TONS OF REFRIGERATION
T-STAT THERMOSTAT
TYP TYPICAL
UB UP-BLAST
UG UNDERGROUND
UH UNIT HEATER
UR URINAL
V SANITARY VENT
VD VOLUME DAMPER
VEL VELOCITY
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W SANITARY WASTE
W/ WITH
WC WATER CLOSET
WCO WALL CLEANOUT
WH WALL HYDRANT
W/O WITHOUT
WTR WATER
GR GRILLE
VAV VARIABLE AIR VOLUME
VTR VENT THROUGH ROOF
INV INVERT
RLF RELIEF
ISO ISOLATION EXHAUST
GEXH GREASE EXHAUST
RH ROOF HYDRANT
YCO YARD CLEANOUT
ZDL ZERO DEADLEG VALVE
AUTOMATIC AIR VENT
AUTOMATIC CONTROL VALVE, 2-WAY
AUTOMATIC CONTROL VALVE, 3-WAY
STRAINER W/BLOWDOWN
CAP AND VALVE
PIPE SPECIALTIES
FLEXIBLE CONNECTION
PIPE ANCHOR
ALIGNMENT GUIDE
STRAINER
PRESSURE REDUCING VALVE
(SETTING AS NOTED, PSI)
EXPANSION JOINT
MANUAL AIR VENT
PRESSURE RELIEF/SAFETY
VALVES(SETTING AS NOTED, PSI)
DRAIN VALVE
REDUCED PRESSURE ZONE BACK
FLOW PREVENTER
DIAPHRAGM
REFRIGERANT SIGHT GLASS
GAS PRESSURE REGULATOR VALVE
BACKWATER VALVE
REFRIGERANT DRYER
FLOW DIRECTION
FLOW DIRECTION W/PITCH
DUPLEX STRAINER
PUMP
THERMOMETER
PRESSURE/TEMPERATURE TEST PORT
STEAM TRAP (TYPE INDICATED)
FLOW SWITCH
PRESSURE GAUGE W/PIGTAIL &
PETCOCK
PRESSURE SWITCH
FLOOR DRAIN
DRAIN ABOVE
FLOOR SINK
WALL HYDRANT
HOSE BIBB
WALL CLEANOUT
ROOF DRAIN
MANHOLE
HB
A
M
FS
PS
GAS COCK VALVE
WH
DEIONIZED WATER RETURNDIR
CLEAN DRY AIRCDA
REVERSE OSMOSISRO
CONTROLS
AQUA STAT
TAMPERPROOF THERMOSTAT
HUMIDISTAT OR R.H. SENSOR
REFRIGERANT SENSOR
SMOKE DETECTOR
SPACE TEMPERATURE SENSOR
STATIC PRESSURE SENSOR
ROOM PRESSURE MONITOR
THERMOSTAT
THERMOSTAT W/GUARD
CARBON MONOXIDE SENSOR
CARBON DIOXIDE SENSOR
DIFFERENTIAL PRESSURE SENSOR
TEMPERATURE SENSOR
A
CO2
CO
H
R
P
SD
TS
SP
PS
T
T
T
DP
TS
P
DUCTWORK
SUPPLY AIR OR OUTDOOR AIR
RETURN AIR
EXHAUST AIR
STANDARD BRANCH, NO SPLITTER -
SUPPLY FLOW TO RIGHT -
RETURN/EXHAUST FLOW TO LEFT
BELLMOUTH WITH BALANCING
DAMPER
FLEXIBLE DUCT
TURNING VANES
FLEXIBLE CONNECTION
MANUAL VOLUME DAMPER
MOTORIZED DAMPER
TYPE:
FD = FIRE DAMPER
SD = SMOKE DAMPER
FSD = COMBINATION FIRE/SMOKE
DAMPER
CRD = CEILING RADIATION DAMPER
ORIENTATION:
SUPPLY GRILLE OR REGISTER
RETURN DUCT UP, NEGATIVE
PRESSURE
SUPPLY DIFFUSER/REGISTER
BLANKOFF INDICATED
RETURN OR EXHAUST GRILLE OR
REGISTER
SUPPLY DUCT UP, POSITIVE
PRESSURE
EXHAUST DUCT UP, NEGATIVE
PRESSURE
RETURN GRILLE/REGISTER
EXHAUST GRILLE/REGISTER
LINEAR DIFFUSER
CONCENTRIC DUCT TRANSITION
ECCENTRIC DUCT TRANSITION
RECTANGULAR-TO-ROUND DUCT
TRANSITION
VAV BOX
REHEAT COIL
VAV BOX W/ REHEAT COIL
DUCT OFFSETS
DUCT CUTLINE
M
XXX
RETURN DUCT DN, NEGATIVE
PRESSURE
SUPPLY DUCT DN, POSITIVE
PRESSURE
EXHAUST DUCT DN, NEGATIVE
PRESSURE
DROPRISE
VERTICAL
XXX
XXX
XXX
ACTUATOR (AS
APPLICABLE)
HORIZONTAL
BLADE/CURTAIN
FIRE, SMOKE, AND
COMBINATION
FIRE/SMOKE DAMPERS
TYPE
ORIENTATION
AIRFLOW MEASURING STATIONAFMS
VAV BOX W/ DUCT SILENCER
VENTURI TYPE AIR VALVE
VAV BOX W/ DUCT SILENCER
& REHEAT COIL
VAV BOX W/ ELECTRIC REHEAT
ENERGY METER
FLOW METER
GPM
EM
WATER HAMMER ARRESTOR
CATCH BASIN
BALANCE VALVE
GENERAL DUTY VALVES
CHECK VALVE
SHUTOFF VALVE
PLUG VALVE
BALL VALVE
BUTTERFLY VALVE
GLOBE ANGLE VALVE
O. S. & Y. VALVE
SOLENOID VALVE
FLOW LIMITING VALVE
GLOBE VALVE
S
OR
OR
OR
OR
OR
GATE VALVE
NITROGEN OXIDE SENSORNOX
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
© 2025 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/03/26
I HEREBY CERTIFY THAT THIS
PLAN, SPECIFICATION, OR REPORT
WAS PREPARED BY ME OR UNDER
MY DIRECT SUPERVISION AND
THAT I AM A DULY LICENSED
PROFESSIONAL ENGINEER UNDER
THE LAWS OF THE STATE OF
MINNESOTA.
Steven C Harmon
23501
A u to d e s k D o c s /R
P S
E lt o n
H ill s E
S W in d o w
R e p la c e m e n t/ M
E P
E lt o n
H ils
E S
W in d o w s R e p la c e m e n t (R rv t
/3 /2
:5
:5
A M
M0
03/03/26
MECHANICAL SYMBOLS AND
ABBREVIATIONS
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S E
L T
O N
H
IL
L S
E S
W
IN
D O
W R
E P
L A
C E
M E
N T
1226041
03/03/26
MJS
SCH
MECHANICAL SHEET LIST
SHEET
NUMBER SHEET NAME
M0 MECHANICAL SYMBOLS AND ABBREVIATIONS
M1 MECHANICAL PLANS
SHEET TOTAL: 2
M
DN
M
KEY NOTES: KEY NOTES:
BOILER
ROOM
CLASSROOM
CORRIDOR
DATA
150A
COMPUTER
150B
CORRIDOR
MEDIA
CLASSROOM
CLASSROOM
CLASSROOM
BOYS
STAFF
RESTROOM
STAFF
RESTROOM
GIRLS
SMALL
GROUP
RECEPTION/WAITING
NURSE
101A
MAIN OFFICE
BOILER
ROOM
CLASSROOM
CORRIDOR
DATA
150A
COMPUTER
150B
CORRIDOR
MEDIA
CLASSROOM
CLASSROOM
CLASSROOM
BOYS
STAFF
RESTROOM
STAFF
RESTROOM
GIRLS
SMALL
GROUP
RECEPTION/WAITING
NURSE
101A
MAIN OFFICE
1 LOUVER TO BE REMOVED BY GENERAL CONTRACTOR.
DISCONNECT CONTROL WIRING. REMOVE MOTORIZED DAMPER AND
DUCT SLEEVE. SAVE FOR REINSTALLATION.
1 NEW LOUVER BY GENERAL CONTRACTOR.
REINSTALL EXISTING MOTORIZED DAMPER AND DUCT SLEEVE.
PROVIDE TRANSITION TO NEW LOUVER. CONFIRM SIZE WITH
GENERAL CONTRACTOR. RECONNECT CONTROL WIRING.
SHEET NUMBER
ISSUE/REVISION HISTORY
CHECKED BY
DRAWN BY
DATE
PROJECT
NUMBER
NUMBER DATE
OF SHEETS
© 2025 CRW architecture + design group
No. ISSUED FOR DATE
211 11th ave nw rochester, mn 55901
p. 507.206.6201
f. 507.206.46.21 www.crwarchitecture.com
CLIENT
100% CDs 03/03/26
I HEREBY CERTIFY THAT THIS
PLAN, SPECIFICATION, OR REPORT
WAS PREPARED BY ME OR UNDER
MY DIRECT SUPERVISION AND
THAT I AM A DULY LICENSED
PROFESSIONAL ENGINEER UNDER
THE LAWS OF THE STATE OF
MINNESOTA.
Steven C Harmon
23501
A u to d e s k D o c s /R
P S
E lt o n
H ill s E
S W in d o w
R e p la c e m e n t/ M
E P
E lt o n
H ils
E S
W in d o w s R e p la c e m e n t (R rv t
/3 /2
:5
:5
A M
M1
03/03/26
MECHANICAL PLANS
R O
C H
E S
T E
R M
IN
N
E S
O T
A
R P
S E
L T
O N
H
IL
L S
E S
W
IN
D O
W R
E P
L A
C E
M E
N T
1226041
03/03/26
MJS
SCH
1/8" = 1'-0"
PARTIAL MECHANICAL DEMOLITION PLAN
1/8" = 1'-0"
PARTIAL MECHANICAL PLAN
DESIGNATIONSSYMBOL
MTG
HT
SYMBOL SCHEDULE NOTES
THESE SYMBOLS COMPRISE A STANDARD LIST, NOT ALL SYMBOLS MAY
APPEAR ON THESE DRAWINGS.
MOUNTING HEIGHTS INDICATED ARE STANDARD. DIMENSIONAL NUMBERS
INDICATED AT DEVICES SHALL OVERRIDE THESE STANDARDS. MOUNTED
HEIGHTS ARE TO THE CENTER OF THE DEVICE, UNLESS NOTED OTHERWISE.
MOUNTING HEIGHTS INDICATED ARE FOR STUD WALL CONSTRUCTION.
WHEN BLOCK OR BRICK CONSTRUCTION IS USED, ADJUST MOUNTING
HEIGHTS TO ALIGN DEVICE PLATES WITH RUNNING JOINT.
REFER TO SPECIFICATIONS FOR FURTHER INFORMATION.
GENERAL
DARK DASHED LINE WEIGHT INDICATES
EXISTING ITEM TO BE REMOVED.
LIGHT SOLID LINE WEIGHT INDICATES EXISTING
ITEM TO REMAIN.
DARK SOLID LINE WEIGHT INDICATES NEW ITEM
OR NEW LOCATION.
REMOVE EXISTING ITEM
REMOVE EXISTING ITEM AND RELOCATE AS INDICATED
NL
EXISTING ITEM TO REMAIN
NEW LOCATION FOR RELOCATED ITEM
NOTES & TAGS
EQUIPMENT IDENTIFICATION TAG - SEE EQUIPMENT SCHEDULES
FEEDER SIZE TAG - SEE POWER RISER SCHEDULE
ELEC EQUIP CONNECTION TAG - SEE EQUIP SCHEDULE
KEYNOTE
MISCELLANEOUS NOTE
#/C
XX
LIGHTING CONTROL SEQUENCE - SEE SCHEDULE
LC
XXX-X
RACEWAYS
CONDUIT CONCEALED IN CEILING OR WALLS
CONDUIT CONCEALED IN THE FLOOR OR BELOW
CONDUIT EXPOSED ON THE CEILING OR WALLS
CONDUIT BURIED UNDERGROUND (# = DEPTH)
CONDUIT WITH BEND DOWN
CONDUIT WITH BEND UP
CONDUIT WITH BUSHED END
CONDUIT WITH BREAK OR CONTINUATION
UG
CIRCUIT HOME RUN
- L1 INDICATES PANEL
- NUMBER
L1 1,3,5
JUNCTION BOX - WALL/CEILING MOUNT
WIREWAY, DUCT BANK, OR FLOOR DUCT AS NOTED
CABLE TRAY, TYPE/SIZE AS INDICATED
J J
X
R
RL
ELECTRICAL ABBREVIATIONS
AMPERES
ABOVE
ADDENDUM
AVAILABLE FAULT CURRENT
ABOVE FINISHED FLOOR
AIR HANDLING UNIT
ALUMINUM
ANTENNA
A, AMP
ABV
ADD
AFC
AFF
AHU
AL
ANT
ABOVE COUNTERAC
ARC FAULT CIRCUIT INTERRUPTERAFCI
BELOW FINISHED CEILING
BOLTED PRESSURE SWITCH
BFC
BPS
AUTOMATIC TRANSFER SWITCHATS
BUILDING AUTOMATION SYSTEMBAS
COPPER
DISTRIBUTED ANTENNA SYSTEM
ELECTRICAL CONTRACTOR
ELECTRIC OR ELECTRICAL
EMERGENCY
ELECTRICAL METALLIC TUBING
ENCLOSURE
ELECTRIC PNEUMATIC
EMERGENCY POWER OFF
CU
DAS
EC
ELEC
EM
EMT
ENCL
EP
EPO
CONDUIT OR CONTROLLED RECEPT
CIRCUIT BREAKER
CLOSED CIRCUIT TV
CIRCUIT
CABINET
C
CAB
CB
CCTV
CKT
ELECTRIC WATER COOLER
FUSE OR FUSED
FIRE ALARM
FLOOR BOX
FIRE-SMOKE DAMPER
GROUND
GROUND FAULT CIRCUIT INTERRUPTER
ISOLATED GROUND
JUNCTION BOX
KILOVOLT
KILOVOLT-AMP
KILOWATT
KILOWATT-HOUR
FILM VIEWER
EWC
F
FA
FB
FSD
FV
G, GND
GFI, GFCI
IG
JBOX
KV
KVA
KW
KWH
MAIN CIRCUIT BREAKER
MOMENTARY CONTACT OR
NATIONAL ELECTRICAL CODE
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
PULL BOX OR PUSHBUTTON
NORMALLY OPEN
NORMALLY CLOSED
MAIN SWITCHBOARD
MC
MCB
MSB
NC
NEC
NIC
NO
NTS
OC
PB
MAIN LUG ONLYMLO
MOTOR RATED SWITCHMR
EMPTYMT
PNEUMATIC ELECTRIC
POWER FACTOR
PHASE
PRIMARY
PANEL
REFRIGERATOR
SECONDARY
SWITCH
SWITCHBOARD
SPEAKER
ROOF TOP UNIT
RECEPTACLE
TELEPHONE
PE
PF
PH
PNL
PRI
RECEPT
REFG
RTU
SEC
SW
SWBD
SPKR
TEL
TAMPER RESISTANTTR
THERMOSTAT
TYPICAL
UNDER COUNTER
UNDER GROUND
UNLESS NOTED OTHERWISE
VOLT OR VOLTAGE
VOLT-AMP
VOLTS ALTERNATING CURRENT
UNIT HEATER
VOLTS DIRECT CURRENT
WATT, WIRE OR WALL PHONE
WEATHERPROOF
EXISTING
TSTAT
TYP
UC
UG
UH
UNO
V
VA
VAC
VDC
W
WP
X
UNIVERSAL SERIAL BUSUSB
18"
18"
18"
18"
18"
18"
18"
VERIFY
VERIFY
VERIFY
VERIFY
VERIFY
VERIFY
VERIFY
VERIFY
VERIFY
18"
18"
18"
18"
BRANCH CIRCUIT PANEL
EQUIPMENT CABINET
TS=TRANSFER SWITCH
MOTOR OR MOTOR CONNECTION
MOTOR CONTROLLER, STARTER OR VFD
COMBINATION STARTER & DISCONNECT SWITCH
FUSED DISCONNECT SWITCH
MOTOR RATED TOGGLE
MANUAL MOTOR STARTER SWITCH WITH THERMAL
OVERLOAD
DUPLEX RECEPTACLE - WALL/CEILING MOUNT
EMERGENCY DUPLEX RECEPTACLE - WALL/CEILING
MOUNT
QUADPLEX RECEPTACLE - WALL/CEILING MOUNT
GFI RECEPTACLE, DUPLEX/QUADPLEX - WALL MOUNT
SPECIAL PURPOSE RECEPTACLE - WALL/CEILING
MOUNT
POKE-THRU - DEVICES AS INDICATED
POWER POLE - DEVICES AS INDICATED
EMERGENCY SPECIAL PURPOSE RECEPTACLE -
WALL/CEILING MOUNT
MR
MMS
G G
P
GFI DEAD FRONT DEVICE, NORMAL/EMERGENCY -
WALL MOUNT
C
SPLIT DUPLEX RECEPTACLE - WALL/CEILING MOUNT
SIMPLEX RECEPTACLE - WALL/CEILING MOUNT
EMERGENCY SIMPLEX RECEPTACLE - WALL/CEILING
MOUNT
DUPLEX RECEPTACLE - CONTROLLED - WALL/CEILING
MOUNT
EMERGENCY QUADPLEX RECEPTACLE - WALL/CEILING
MOUNT
GROUND REFERENCE BUS - AS NOTED - WALL/CEILING
MOUNT
VERIFY
EMERGENCY SPLIT DUPLEX RECEPTACLE -
WALL/CEILING MOUNT
LIGHT FIXTURE ID - REFER TO LIGHT FIXTURE SCHEDULE
(SCHEDULE OVERRIDES SYMBOL ABBREVIATION)
A - INDICATES LIGHT FIXTURE TYPE
# - INDICATES CIRCUIT NUMBER
b - INDICATES SWITCHING
LIGHT FIXTURE CIRCUIT TYPE
- NO HATCH INDICATES NORMAL CIRCUIT
- ANGLED HATCH INDICATES CRITICAL CIRCUIT
- SOLID HATCH INDICATES LIFE SAFETY CIRCUIT
TROFFER TYPE LIGHT FIXTURE, SIZE AS INDICATED -
CEILING MOUNT
CHANNEL OR INDUSTRIAL, LENGTH AS INDICATED
ROUND DOWNLIGHT, RECESSED OR SURFACE MOUNT
CEILING WALL WASH FIXTURE OR TRACK HEAD
WALL MOUNT FIXTURE OR SCONCE
LINEAR RECESSED, LENGTH AS INDICATED
UNDER CABINET FIXTURE, LENGTH AS INDICATED
TRACK FIXTURE, NUMBER OF HEADS AS INDICATED
EMERGENCY BATTERY LIGHT - WALL/CEILING MOUNT
EXIT LIGHT, FILLED QUADRANT INDICATES FACES -
WALL/CEILING MOUNT
VERIFY
SITE LIGHTING ROUND OR SQUARE BOLLARD
SITE LIGHTING POLE FIXTURE, ROUND/RECTANGLE
HEAD - NUMBER OF HEADS INDICATED
b
A
LINEAR SUSPENDED , LENGTH AS INDICATED VERIFY
VERIFY
SQUARE DOWNLIGHT, RECESSED OR SURFACE MOUNT
CHANNEL OR INDUSTRIAL WALL MOUNT, LENGTH AS
INDICATED
ROUND OR SQUARE PENDANT
TAPE OR ROPE LIGHT
VANITY FIXTURE
WALL PACK
FLAG OR FLOOD LIGHT
VERIFY
VERIFY
SINGLE POLE TOGGLE SWITCH
DOUBLE POLE TOGGLE SWITCH
THREE WAY TOGGLE SWITCH
FOUR WAY TOGGLE SWITCH
TOGGLE SWITCH - "a" INDICATES SWITCHING a
48"
PILOT LIGHT TOGGLE SWITCH
ILLUMINATED TOGGLE - TOGGLE SWITCH
KEYED SWITCH
MOMENTARY CONTACT TOGGLE SWITCH
TIMER SWITCH
DIMMER SWITCH
OCCUPANCY SENSOR - CLG MOUNT
OCCUPANCY SENSOR WALL SWITCH
PHOTO ELECTRIC CELL
TIME CLOCK
CONTACTOR
RELAY
IL
K
MC
TS
OS
PUSH BUTTON STATION - BUTTONS AS INDICATED
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
60"
60"
PC
TC
C
R
D
MULTI SWITCH, MULTI GANG BOX 48"
VERIFY
VERIFY
PUSH BUTTON SWITCHB 48"
SIGNAL AND COMMUNICATIONS
DATA OUTLET - WALL/CEILING MOUNT
(# = WIRE COUNTS)
VOICE/DATA OUTLET - WALL/CEILING MOUNT
FLOOR OUTLET (# = WIRE COUNTS)
WALL PHONE - HIGH WALL MOUNT
WIRELESS ACCESS POINT - WALL/CEILING MOUNT
18"
SPEAKER - WALL/CEILING MOUNT
HORN SPEAKER - WALL MOUNT
VOLUME SWITCH - WALL MOUNT
AUDIO JACK (M=MICROPHONE, A=AUXILIARY)
BUZZER - WALL/CEILING MOUNT
BELL - WALL/CEILING MOUNT
CHIME - WALL/CEILING MOUNT
CLOCK - WALL/CEILING MOUNT (# = DIAMETER)
PROJECTOR/VIDEO CAMERA/DOCUMENT
CAMERA - WALL/CEILING MOUNT
TV SYSTEM OUTLET - WALL/CEILING MOUNT
ANNUNCIATOR PANEL - WALL MOUNT TYPICAL
60"
96"
48"
18"
96"
VERIFY
18"
WALL INTERCOM STATION (M=MASTER, R=REMOTE) 48"
96"
96"
96"
18"
96"
W
PRJ
AUDIO VIDEO SYSTEM OUTLET - WALL/CEILING MOUNT 18"
A/V SYSTEMS CONTROLLER - WALL MOUNT 18"
S
S S
C C
ICM
AM
V
VID
SECURITY
SECURITY - WALL MOUNT - TYPICAL
ES
EL
DC
GB
48"
SECURITY PANEL - WALL MOUNT - TYPICAL VERIFY
S
S
SECURITY CAMERA - WALL/CEILING MOUNT
VERIFY
CR
EP
SECURITY - CEILING MOUNT - TYPICAL
SWITCHES AND CONTROLS
LIGHTING
POWER
A.
B.
C.
D.
TRANSFORMERXFMR
ABOVE GRADEAG
AUDIBLE ALARMAA
CEILING CLG
DOWNDN
DEDICATEDDED
COMMUNICATIONSCOMM
CONTROL CTRL
FIRE ALARM ANNUNCIATOR PANELFAAP
FIRE ALARM CONTROL PANELFACP
FIBER OPTICFO
SINGLE MODE FIBER OPTICSMFO
MULTI MODE FIBER OPTICMMFO
GROUND FAULT EQUIPMENT PROTECTIONGFEP
GENERAL CONTRACTORGC
CURRENT TRANSFORMERCT
ABOVE COUNTER HEIGHTACH
AUDIO VISUALAV
AMERICAN WIRE GAUGEAWG
MOTOR CONTROL CENTERMCC
METER M
MAN HOLEMH
NEUTRALN
HAND HOLEHH
HAND OFF AUTOHOA
POTENTIAL TRANSFORMERPT
MECHANICAL CONTRACTOR
RACEWAYR
UNDER FLOORUF
WIRELESS ACCESS POINTWAP
SHIELDED TWISTED PAIRSTP
SUBSTATIONSUB
UNSHIELDED TWISTED PAIRUTP
ELECTRICAL GROUND BAREGB
SERVICE GROUND BARSGB
TELECOMMUNICATIONSTELCOM
TELECOMMUNICATIONS MAIN GROUND BARTMGB
TELECOMMUNICATIONS GROUND BARTGB
DESIGNATIONSSYMBOL
MTG
HT
DESIGNATIONSSYMBOL
MTG
HT
ELECTRICAL SYMBOLS LEGEND
VERIFY
VERIFY
C
18"
A/V MONITOR - WALL MOUNT 18"MT
CX
AV
TV
AV
TV
X" H X" W
X' - X" AFF
CABLE TRAY TAG
X" W - WIDTH OF CABLE TRAY
X" H - HEIGHT OF CABLE TRAY
X' - X" AFF - MOUNTING HEIGHT OF CABLE TRAY (FROM FINISH
FLOOR TO BOTTOM OF TRAY)
GFI RECEPTACLE, DUPLEX/QUADPLEX - CEILING MOUNT
18"
UTILITY SERVICE:
EQUIPMENT ID
VOLTAGE, PHASE, 3 OR 4 WIRE
ONE LINE AND RISER
ID
V, Ø, W
XX
AF/AT
XX
AF/AT
XX
AF/AT
XX
AF/AT
600 VOLT MOLDED CASE CIRCUIT BREAKER:
AF = AMP FRAME, AT = AMP TRIP
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
OPTIONS ABBREVIATIONS:
LSI = LONG TIME/SHORT TIME/INSTANTANEOUS TRIP SETTINGS
LSIG = LSI WITH GROUND FAULT PROTECTION
EO=ELECTRICALLY OPERATED
M1=METER (REFER TO METER SCHEDULE)
ST=SHUNT TRIP
K1=KIRK KEYED (REFER TO KIRK KEY SCHEDULE)
600 VOLT INSULATED CASE CIRCUIT BREAKER:
AF = AMP FRAME, AT = AMP TRIP
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
600 VOLT DRAWOUT CIRCUIT BREAKER:
AF = AMP FRAME, AT = AMP TRIP
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
15,000 VOLT DRAWOUT CIRCUIT BREAKER:
AF = AMP FRAME, AT = AMP TRIP
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
K1
M A V
M M M
MMM
XX
ID
V, Ø, W
A MCB
SPACES
KAIC
XX
AS
DISCONNECT SWITCH:
AS = AMP SWITCH
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
XX
AF
FUSE:
AF = AMP FUSE
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
XX
AS/AF
FUSED DISCONNECT SWITCH:
AS = AMP SWITCH, AF = AMP FUSE
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
ID
KVA
V
MF
ID
V, Ø, W A
XX
KAIC
ID
HP
Ø
ID
KW/KVA
V, Ø, W
PF
ENGINE GENERATOR:
EQUIPMENT ID
KW/KVA RATING OF GENERATOR
VOLTAGE, PHASE, 3 OR 4 WIRE, POWER FACTOR
TRANSFER SWITCH:
EQUIPMENT ID
VOL…