This is a Final Design document for a federal construction project at the 934th Airlift Wing, United States Air Force Reserve facility located at 760 Military Highway, Minneapolis, Minnesota 55450-2100.

The project, designated QJKL 26-0019, involves sustaining hangar doors at Buildings 821 and 870. Building 821 features a 200-foot, 2-inch-wide south elevation with multiple rolling hangar doors requiring paint application to metal panels above the doors and brown paint on the lower overhead door to match adjacent metal panels. The rolling hangar doors themselves also require painting. Building 870 contains a 162-foot, 11-inch-wide south elevation with six-section rolling hangar doors and a roll-up tail door; both the rolling hangar doors and tail door require paint application, along with metal panels above the rolling doors. The work includes protecting signs from paint and overspray. General notes specify that Buildings 821 and 870 are used for aircraft maintenance with doors requiring opening and closing to allow aircraft entry/exit, with project phasing to be coordinated with the project engineer. The contractor must keep all work areas clean, test hangar door paint on both facilities for lead content per specifications, and use designated free zones for parking and material storage with appropriate security escort requirements when transitioning between the entry gate and work zones. Restroom facilities are not available for contractor use and must be relocated as work progresses.

View the file

Other files

File Type Posted
1-Statement Of Work.pdf PDF
Solicitation - FA663326Q0004.pdf PDF
4-Wage Determination.pdf PDF
2-Specifications.pdf PDF
Attach. 5 Submittal Register.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VICINITY MAP

SCALE: N.T.S.

STATE OF MINNESOTA

SCALE: N.T.S.

p I-494

MINNEAPOLIS - SAINT PAUL

INTERNATIONAL AIRPORT

MSP ARS

MILITARY HIGHWAY

G R

IS

SO

M

AV

E

EA

R

H

AR

T

AV

E

KI

TT

YH

AW

K

AV

E

6TH STREET

5TH STREET

LI

N

BE

R

G A

VE

S

TH

A

VE

D E

S C

R

IP

T

IO

N M

A R

K

4T

H A

IR

LI

F T

W

IN

G , U

S A

F R

M

IL

IT

A

R Y

H

IG

H W

A Y

M

IN

N E

A P

O

LI

S , M

N

0-

B U

IL

D

IN

G

4T

H C

IV

IL

E N

G

IN

E E

R

IN

G

S U

S T

A

IN

H A

N G

A R

D O

O R

S , B

LD

G

S

Q

JK

L

-0

T

IT

LE

S

H E

E T

C D

D 5/

5/

C D

D

T M

T

D w n by

D es ig ne d by

R ev ie w ed b y:

D at e:

R ev

S ub m itt ed b y:

A W

Sheet 1 of 6

SHEET ID:

T001

D A

T E

MINNEAPOLIS MINNESOTA

760 MILITARY HIGHWAY

55450-2100

934th AIRLIFT WING

UNITED STATES AIR FORCE RESERVE

SUSTAIN HANGAR DOORS, BLDGS 821 & 870

PROJECT # QJKL 26-0019

FL

YING

VIKINGS

FINAL DESIGN

4 TH

T W

LRIA I

G

N

I F

SHEET # DESCRIPTION

T001 TITLE SHEET

G001 FREE ZONE PLAN

G002 PHOTOS

A101 BLDG 821 SOUTH ELEVATION

A102 BLDG 821 NORTH ELEVATION

A103 BLDG 870 SOUTH ELEVATION

PROJECT LOCATION

VISITORS CENTER

COMMERCIAL INSPECTION

CIVIL ENGINEERING

Scale: N.T.S.

PROJECT LOCATION 1

AutoCAD SHX Text

MINNEAPOLIS

AutoCAD SHX Text

SAINT PAUL

AutoCAD SHX Text

DULUTH

AutoCAD SHX Text

AIRPORT

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TH

AutoCAD SHX Text T

AutoCAD SHX Text W

AutoCAD SHX Text L

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text F

AutoCAD SHX Text

FI

AL

D

ES

IG

N

852853

D E

S C

R

IP

T

IO

N M

A R

K

4T

H A

IR

LI

F T

W

IN

G , U

S A

F R

M

IL

IT

A

R Y

H

IG

H W

A Y

M

IN

N E

A P

O

LI

S

0-

B U

IL

D

IN

G

4T

H C

IV

IL

E N

G

IN

E E

R

IN

G

S U

S T

A

IN

H A

N G

A R

D O

O R

S , B

LD

G

S

Q

JK

L

-0

F R

E E

Z O

N E

P

LA

N

C D

D 5/

5/

C D

D

T M

T

D w n by

D es ig ne d by

R ev ie w ed b y:

D

S ub m itt ed b y:

Sheet 2 of 6

G001

D A

T E

Scale: N.T.S.

FREE ZONE PLAN1

FREE ZONE NOTES:

1. FREE ZONES 1 & 2 ARE LOCATED IN THE RESTRICTED

AREA AND MUST BE ENCLOSED WITH A 4' ORANGE SNOW

FENCE SUPPORTED BY WATER FILLED LOW-PROFILE

BARRIERS WITH RED FLASHING LIGHTS AND SPACED AT

50' MAXIMUM AND IN ACCORDANCE WITH UFC 3-270-04

SEE DETAIL THIS SHEET.

2. FREE ZONE 3 DOES NOT REQUIRE LOW-PROFILE

BARRIERS WITH FLASHING LIGHTS AND MAY BE ENCLOSED

WITH WEIGHTED STANCHIONS CONNECTED WITH YELLOW

ROPE SPACED AT 25' INTERVALS.

3. PARKING/LAYDOWN AREA

THE CONTRACTOR MAY USE AREAS WITHIN THE

IDENTIFIED FREE ZONE FOR PARKING AND MATERIAL

STORAGE. THE CONTRACTOR IS RESPONSIBLE FOR

PROTECTION OF MATERIALS, TOOLS, AND EQUIPMENT.

4. GOVERNMENT ESCORT

THE CONTRACTOR WILL REQUIRE GOVERNMENT ESCORT

WHEN TRANSITIONING BETWEEN THE ENTRY GATE AND

EACH FREE ZONE. WORK MAY BE PERFORMED INSIDE THE

FREE ZONE WITHOUT ESCORT. FURTHER DETAILS TO BE

DISCUSSED AT THE PRE-CONSTRUCTION MEETING.

N.T.S.

LOW PROFILE BARRICADE2

AutoCAD SHX Text

ENTER

AutoCAD SHX Text

FREE ZONE 3

AutoCAD SHX Text

FREE ZONE 2

AutoCAD SHX Text

FREE ZONE 1

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TH

AutoCAD SHX Text T

AutoCAD SHX Text W

AutoCAD SHX Text L

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text F

AL

D

ES

IG

N

D E

S C

R

IP

T

IO

N M

A R

K

4T

H A

IR

LI

F T

W

IN

G , U

S A

F R

M

IL

IT

A

R Y

H

IG

H W

A Y

M

IN

N E

A P

O

LI

S

0-

B U

IL

D

IN

G

4T

H C

IV

IL

E N

G

IN

E E

R

IN

G

S U

S T

A

IN

H A

N G

A R

D O

O R

S , B

LD

G

S

Q

JK

L

-0

P H

O T

O S

C D

D 5/

5/

C D

D

T M

T

D w n by

D es ig ne d by

R ev ie w ed b y:

D

S ub m itt ed b y:

Sheet 3 of 6

G002

D A

T E

Scale: N.T.S.

BLDG 870 SOUTH ELEVATION3Scale: N.T.S.

BLDG 821 SOUTH ELEVATION1

Scale: N.T.S.

BLDG 821 NORTH ELEVATION2

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TH

AutoCAD SHX Text T

AutoCAD SHX Text W

AutoCAD SHX Text L

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text F

AL

D

ES

IG

N

200'-2"

'-2

9'-10"

'-0

9'-9"

D E

S C

R

IP

T

IO

N M

A R

K

4T

H A

IR

LI

F T

W

IN

G , U

S A

F R

M

IL

IT

A

R Y

H

IG

H W

A Y

M

IN

N E

A P

O

LI

S

0-

B U

IL

D

IN

G

4T

H C

IV

IL

E N

G

IN

E E

R

IN

G

S U

S T

A

IN

H A

N G

A R

D O

O R

S , B

LD

G

S

Q

JK

L

-0

B

LD

G

S O

U T

H E

LE

V

A T

IO

N

C D

D 5/

5/

C D

D

T M

T

D w n by

D es ig ne d by

R ev ie w ed b y:

D

S ub m itt ed b y:

Sheet 4 of 6

A101

D A

T E

Scale: 1/16" = 1'

BLDG 821 - SOUTH ELEVATION1

PAINT METAL PANELS ABOVE

ROLLING DOORS(TYP)

PAINT LOWER OVERHEAD DOOR BROWN TO

MATCH ADJACENT METAL PANELS

PROTECT SIGNS FROM

PAINT & OVERSPRAY (TYP) PAINT ROLLING HANGAR DOORS (TYP)N.I.C.

GENERAL NOTES:

1. BUILDING 821 AND 870 ARE USED FOR AIRCRAFT MAINTENANCE. HANGAR DOORS MAY NEED TO BE OPENED AND CLOSED TO ALLOW AIRCRAFT ENTRY/EXIT. COORDINATE PROJECT PHASING WITH THE

PROJECT ENGINEER.

2. SEE SPECIFICATIONS FOR COLORS AND ESTIMATED QUANTITIES.

3. PARKING/LAYDOWN AREA

THE CONTRACTOR MAY USE AREAS WITHIN THE IDENTIFIED FREE ZONE FOR PARKING AND MATERIAL

STORAGE. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF MATERIALS, TOOLS, AND

EQUIPMENT.

3. RESTROOMS

RESTROOM FACILITIES WILL NOT BE AVAILABLE FOR CONTRACTOR USE. CONTRACTOR WILL REQUIRE PORTABLE FACILITIES. PORTABLE FACILITIES SHALL BE RELOCATED AS WORK PROGRESSES TO THE

NEXT FREE ZONE. CONSULT THE PROJECT ENGINEER FOR POSITIONING.

4. WATER SOURCE

FIRE HYDRANTS ARE AVAILABLE FOR USE NEAR THE HANGAR. IF WATER IS REQUIRED, THE

CONTRACTOR MUST SUPPLY A BACK FLOW PREVENTION DEVICE, HOSE CONNECTION/MANIFOLD

EQUIPPED WITH ISOLATION VALVE, AND HYDRANT WRENCH. HOSE BIBS ARE LOCATED INSIDE THE

HANGAR BUT MAY ONLY BE AVAILABLE IF THE HANGAR IS UNOCCUPIED.

5. LEAD BASED PAINT

HANGAR DOOR PAINT ON BOTH FACILITIES TESTED POSITIVE FOR LEAD. SEE SPECIFICATIONS.

6. ALL WORK AREAS SHALL BE KEPT CLEAN. THE CONTRACTOR SHALL TAKE APPROPRIATE STEPS TO ENSURE NO DEBRIS OR MATERIALS LEAVE THE WORK AREA. NO CLEANING OF EQUIPMENT WILL BE

PERMITTED ON THE INSTALLATION.

N.I.C.

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TH

AutoCAD SHX Text T

AutoCAD SHX Text W

AutoCAD SHX Text L

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text F

AL

D

ES

IG

N

200'-2"

'-0

D E

S C

R

IP

T

IO

N M

A R

K

4T

H A

IR

LI

F T

W

IN

G , U

S A

F R

M

IL

IT

A

R Y

H

IG

H W

A Y

M

IN

N E

A P

O

LI

S

0-

B U

IL

D

IN

G

4T

H C

IV

IL

E N

G

IN

E E

R

IN

G

S U

S T

A

IN

H A

N G

A R

D O

O R

S , B

LD

G

S

Q

JK

L

-0

B

LD

G

N O

R T

H E

LE

V

A T

IO

N

C D

D 5/

5/

C D

D

T M

T

D w n by

D es ig ne d by

R ev ie w ed b y:

D

S ub m itt ed b y:

Sheet 5 of 6

A102

D A

T E

Scale: 1/16" = 1'

BLDG 821 - NORTH ELEVATION1

PAINT METAL PANELS ABOVE

ROLLING DOORS(TYP)

PAINT OVERHEAD DOOR (MATCH EXISTING) PAINT ROLLING HANGAR DOORS (TYP)N.I.C.

GENERAL NOTES:

1. BUILDING 821 AND 870 ARE USED FOR AIRCRAFT MAINTENANCE. HANGAR DOORS MAY NEED TO BE OPENED AND CLOSED TO ALLOW AIRCRAFT ENTRY/EXIT. COORDINATE PROJECT PHASING WITH THE

PROJECT ENGINEER.

2. SEE SPECIFICATIONS FOR COLORS AND ESTIMATED QUANTITIES.

3. PARKING/LAYDOWN AREA

THE CONTRACTOR MAY USE AREAS WITHIN THE IDENTIFIED FREE ZONE FOR PARKING AND MATERIAL

STORAGE. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF MATERIALS, TOOLS, AND

EQUIPMENT.

3. RESTROOMS

RESTROOM FACILITIES WILL NOT BE AVAILABLE FOR CONTRACTOR USE. CONTRACTOR WILL REQUIRE PORTABLE FACILITIES. PORTABLE FACILITIES SHALL BE RELOCATED AS WORK PROGRESSES TO THE

NEXT FREE ZONE. CONSULT THE PROJECT ENGINEER FOR POSITIONING.

4. WATER SOURCE

FIRE HYDRANTS ARE AVAILABLE FOR USE NEAR THE HANGAR. IF WATER IS REQUIRED, THE

CONTRACTOR MUST SUPPLY A BACK FLOW PREVENTION DEVICE, HOSE CONNECTION/MANIFOLD

EQUIPPED WITH ISOLATION VALVE, AND HYDRANT WRENCH. HOSE BIBS ARE LOCATED INSIDE THE

HANGAR BUT MAY ONLY BE AVAILABLE IF THE HANGAR IS UNOCCUPIED.

5. LEAD BASED PAINT

HANGAR DOOR PAINT ON BOTH FACILITIES TESTED POSITIVE FOR LEAD. SEE SPECIFICATIONS.

6. ALL WORK AREAS SHALL BE KEPT CLEAN. THE CONTRACTOR SHALL TAKE APPROPRIATE STEPS TO ENSURE NO DEBRIS OR MATERIALS LEAVE THE WORK AREA. NO CLEANING OF EQUIPMENT WILL BE

PERMITTED ON THE INSTALLATION.

N.I.C.

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TH

AutoCAD SHX Text T

AutoCAD SHX Text W

AutoCAD SHX Text L

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text F

AL

D

ES

IG

N

SIX SECTION ROLLING

HANGAR DOORS

CONC. PANEL

PRECAST

162'-11"

'-7

15'-10"

'-7

8' -5

D E

S C

R

IP

T

IO

N M

A R

K

4T

H A

IR

LI

F T

W

IN

G , U

S A

F R

M

IL

IT

A

R Y

H

IG

H W

A Y

M

IN

N E

A P

O

LI

S

0-

B U

IL

D

IN

G

4T

H C

IV

IL

E N

G

IN

E E

R

IN

G

S U

S T

A

IN

H A

N G

A R

D O

O R

S , B

LD

G

S

Q

JK

L

-0

B

LD

G

S O

U T

H E

LE

V

A T

IO

N

C D

D 5/

5/

C D

D

T M

T

D w n by

D es ig ne d by

R ev ie w ed b y:

D

S ub m itt ed b y:

Sheet 6 of 6

A103

D A

T E

GENERAL NOTES:

1. BUILDING 821 AND 870 ARE USED FOR AIRCRAFT MAINTENANCE. HANGAR DOORS MAY NEED TO BE OPENED AND CLOSED TO ALLOW AIRCRAFT ENTRY/EXIT. COORDINATE PROJECT PHASING WITH THE

PROJECT ENGINEER.

2. SEE SPECIFICATIONS FOR COLORS AND QUANTITIES.

3. PARKING/LAYDOWN AREA

THE CONTRACTOR MAY USE AREAS WITHIN THE IDENTIFIED FREE ZONE FOR PARKING AND MATERIAL

STORAGE. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF MATERIALS, TOOLS, AND

EQUIPMENT.

3. RESTROOMS

RESTROOM FACILITIES WILL NOT BE AVAILABLE FOR CONTRACTOR USE. CONTRACTOR WILL REQUIRE PORTABLE FACILITIES. PORTABLE FACILITIES SHALL BE RELOCATED AS WORK PROGRESSES TO THE

NEXT FREE ZONE. CONSULT THE PROJECT ENGINEER FOR POSITIONING.

4. WATER SOURCE

FIRE HYDRANTS ARE AVAILABLE FOR USE NEAR THE HANGAR. IF WATER IS REQUIRED, THE

CONTRACTOR MUST SUPPLY A BACK FLOW PREVENTION DEVICE, HOSE CONNECTION/MANIFOLD

EQUIPPED WITH ISOLATION VALVE, AND HYDRANT WRENCH. HOSE BIBS ARE LOCATED INSIDE THE

HANGAR BUT MAY ONLY BE AVAILABLE IF THE HANGAR IS UNOCCUPIED.

5. LEAD BASED PAINT

HANGAR DOOR PAINT ON BOTH FACILITIES TESTED POSITIVE FOR LEAD. SEE SPECIFICATIONS.

6. ALL WORK AREAS SHALL BE KEPT CLEAN. THE CONTRACTOR SHALL TAKE APPROPRIATE STEPS TO ENSURE NO DEBRIS OR MATERIALS LEAVE THE WORK AREA. NO CLEANING OF EQUIPMENT WILL BE

PERMITTED ON THE INSTALLATION.

Scale: 1/16" = 1'

BLDG 870 - SOUTH ELEVATION1

PAINT METAL PANELS ABOVE

ROLLING DOORS(TYP)

PAINT ROLL UP TAIL DOOR

PROTECT SIGNS FROM

PAINT & OVERSPRAY (TYP)

PAINT ROLLING HANGAR DOORS (TYP)

N.I.C.N.I.C.

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TH

AutoCAD SHX Text T

AutoCAD SHX Text W

AutoCAD SHX Text L

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text F

File details come from the government source that posted it. Updated .