3. Gate Plans and Drawings.pdf
PDF 1 MB Posted
- Solicitation number
- 127EAW24R0040
- Issued by
-
Department of Agriculture Forest Service
About this file
This document appears to be a set of drawings and plans for a single lane and double lane gate for the Caldor Fire project in the Eldorado National Forest. The drawings depict the dimensions and construction details for the gates, including the lock bar post, concrete base, and reflective markers.
The related federal contract opportunity is Solicitation Number 127EAW24R0040 for the Wrights Lake Visitor Parking Gates project in the Eldorado National Forest. This is a total small business set-aside opportunity with an estimated construction value between $100,000 and $250,000. The solicitation requires proposals to be submitted by 1300 hours PST on June 18th, 2024. A pre-proposal site visit will not be held, but prospective offerors can inspect the project locations on their own.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A00002 - FS Site Visit Information UPDATED.pdf | ||
| A00001 - FS Site Visit Information.pdf | ||
| 2. Schedule.docx | DOCX document | |
| 7. Davis-Bacon Act WD # CA20240007.pdf | ||
| 127EAW24R0040 - Wrights Lake Visitor Parking Gates.pdf | ||
| 6. Fire Plan.pdf | ||
| 1. Statement of Work.pdf | ||
| 4. Forest Service Supplemental Specifications (FSSS).pdf | ||
| 8. RFI Form.docx | DOCX document | |
| 5. Gate Location Map.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CWFSB523�
Single Lane Gate
8. Contractor responsible for acquiring and installing road closed sign and reflective markers.
Double Lane Gate
*** manufacturer may replace the center post with an attached jack to be approved by the COR
DRAWING TITLE
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
-- R
ES
PI
NO
ZA
02 D
RA
W
IN
G3
.D W
G;
(R05)
PACIFIC SOUTHWEST
CALDOR FIRE GATES
ELDORADO NATIONAL
FOREST
LOCK BAR POST
XX/XX/XXXX
X.XXX
X.XXX
X.XXX
X-01
001001
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
HEIGHT WILL VARY
AutoCAD SHX Text
GROUND SURFACE AT SITE
AutoCAD SHX Text
OF LOCKING POST
AutoCAD SHX Text
INSERTED THROUGH POST
AutoCAD SHX Text
(DRILL POST FOR REBAR
AutoCAD SHX Text 2' 0"
AutoCAD SHX Text 3' 0"
AutoCAD SHX Text 1' 6"
AutoCAD SHX Text
#4 X 14" REBAR
AutoCAD SHX Text 1' 0"
AutoCAD SHX Text 1' 0"
AutoCAD SHX Text
4" STEEL PIPE
AutoCAD SHX Text
90 DEGREES APART)
AutoCAD SHX Text
WELDED GUSSET
AutoCAD SHX Text
FOR SUPPORT
AutoCAD SHX Text 6 "
AutoCAD SHX Text
CONCRETE (TYP)
AutoCAD SHX Text
CAST-IN-PLACE
AutoCAD SHX Text USE 1/2" x 2" x 6" STEEL FLAT BAR, FIELD WELDED TO LOCK BACK POST TO CRADLE AND SUPPORT GATE CROSSARM
AutoCAD SHX Text
6" X 12" TYPE II OBJECT MARKER ATTACHED TO BOTH SIDES OF POST
AutoCAD SHX Text WELD 3/8" x 4" END CAP
AutoCAD SHX Text
3 FT. OF 3/8" HARDENED CHAIN, WELDED TO POST @ CENTER OF CHAIN
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
| Gate Lock Bar Typical.pdf |
| Sheets and Views |
| 17X11 EXPANDED |
File details come from the government source that posted it. Updated .