This is a bid set of construction plans for the Donner Trail Park project located in Salt Lake City, Utah, prepared by Arc Site Design Landscape Architecture and Architectural Site Design. The project, administered by Salt Lake City Public Utilities, encompasses comprehensive park improvements including replacement of playgrounds and play safety surfacing, replacement of drinking fountains, installation of new artwork and signage, addition of plantings, and modifications to existing irrigation and storm drainage systems. The bid set includes detailed plans and specifications covering site layout, materials, landscape design, irrigation systems, and existing tree inventory. The project requires compliance with the International Plumbing Code, Utah Drinking Water Regulations, APWA Manual of Standard Plans and Specifications, and Salt Lake City Public Utilities standards. The contractor must coordinate with multiple city departments and agencies including Public Utilities, Engineering, Fire Department, Planning and Zoning, Transportation, as well as county entities, prior to construction commencing within 48 hours of notification.

The construction plans specify detailed requirements for utility trenching, backfill procedures, concrete pavement demolition and installation, streetlighting, tree protection, landscape planting specifications, and irrigation system installation and modifications. The irrigation plan includes provisions for head-to-head coverage, pressure maintenance, hydrometer installation, and coordination with existing controllers. The landscape design incorporates specific plant species with identified sizes and conditions, native seed mix specifications for disturbed areas, and detailed planting and mulching requirements. Concrete collars must be constructed on all manholes, cleanout boxes, catch basins, and valves per Public Utilities standards, with all service points coordinated with the appropriate entities. The contractor bears responsibility for maintaining existing irrigation systems during construction and repairing or replacing any site items damaged during the course of work.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HAROLD '

r

" w

"' u, OFILL

.J l if.>

SAL i LAKE CITY 1/

INTERNATIONAL 1--AIRPORT

\ "' li"c, ~ ru ,f-

1 .!, >

~ ) I-

0 tf' .

'%,.,_ j w v-

1 \~

TTY DRIVE 600 NORTH

cP. { TH AVENUE r ~

"' N~ MPLE

~ " '-..,/ ;., SOUTH TEMPLE y \. , I-so r l " w

::, ~OD S[ UTH

500 S□ UTI-\ - 0 \

" 0 v 0

700 SOUTH <I 0

D "' 800 SOUTH >- " INDIANA-, 5 900 SOUTH f " t J iE D u, D 'i' " @ ;,, >-

CALIFORNIA AVE__

<I .!, " w

--.I D kl CALIFORNIA '1;:, ~

" \,, " ~ ~ >- >- >-w " " " ~\ w ' <I <I z w w w a D

0: £ <I 0 =

"' >- 0 =

1- "

SR 201 ~ ~ 2100 □UTf

SR-201

,_ 80

VICINITY MAP @

NORTH

NOTTO SCALE

UNIVERSITY

□F UTAH

SUNNYSIDE

" <I w cl oooe onm"

PROJECT

LOCATION

AVE

z

'e> ~'? ~ ~

' 'L

REIMAGINE DONNER TRAIL PARK

PRK24028

2903 KENNEDY DR

SALT LAKE CITY, UTAH

DECEMBER 16, 2025

SHEET SET ASSEMBLY ORDER

SHEET

DESIGNATOR

SDOOO

SD100

SD101-106

SD501

LM100

LM101-106

LM501-LM502

LL100

LL 101-106

LL501

LR100

LR101-106

LR501

BINDING

ORDER

4-9 12-17 18-19 21-26 29-34

SHEET

TITLE

COVER SHEET

EXISTING TREE INVENTORY

OVERALL SITE DEMOLITION PLAN

SITE DEMOLITION PLAN

SITE DEMOLITION NOTES & DETAILS

OVERALL LAYOUT AND MATERIALS PLAN

LAYOUT AND MATERIALS PLAN

LAYOUT AND MATERIALS DETAILS

OVERALL LANDSCAPE PLAN

LANDSCAPE PLAN

LANDSCAPE DETAILS

OVERALL IRRIGATION PLAN

IRRIGATION PLAN

IRRIGATION DETAILS

CITY OFFICIALS

MAYOR

CITY COUNCIL DIST. 1

DIST. 2

DIST. 3

DIST. 4

DIST. 5

DIST. 6

DIST. 7

PUBLIC SERVICES DIRECTOR

CITY ARCHITECT

ERIN MENDENHAIL

VICTORIA PETRO

ALEJANDRO PUY

CHRIS WHARTON

EV A LOPEZ CHAVEZ

ERIKA CARLSEN

DAN DUGAN

SARAH YOUNG

JORGE CHAMORRO

SEAN FYFE, AIA

PUBLIC LANDS DIRECTOR CITY ARCHITECT

KIM SHELLEY DATE SEAN FYFE, AIA DATE

e sunnyside ave s wasatch dr oak hills way emigration canyon rd

* PROJECT

LOCATION

~=====k=en=ne=dy=dr ==:::::::::::::::-_ f

~~y dr

SITE ORIENTATION MAP @

NORTH

NOTTO SCALE

PUBLIC LANDS PROJECT MANAGER SENIOR CONSTRUCTION MANAGER LANDSCAPE ARCHITECT

ARCSITIO DESIGN

KIRA JOHNSON DATE TROY ANDERSON, PLA DATE STEVEN GILBERT DATE

I ll.I en Cl -m

I ll.I

II.I

:z:

en a:

II.I

0 u

02/06/2026

Kira Johnson (Feb 6, 2026 15:59:35 MST) 02/06/2026 02/06/202602/17/2026

02/17/2026 https://secure.na1.documents.adobe.com/verifier?tx=CBJCHBCAABAAlVhU_AyuXlANWfgIFqmDn3Yo_wBG3nEZ https://secure.na1.documents.adobe.com/verifier?tx=CBJCHBCAABAAlVhU_AyuXlANWfgIFqmDn3Yo_wBG3nEZ https://secure.na1.documents.adobe.com/verifier?tx=CBJCHBCAABAAlVhU_AyuXlANWfgIFqmDn3Yo_wBG3nEZ https://secure.na1.documents.adobe.com/verifier?tx=CBJCHBCAABAAlVhU_AyuXlANWfgIFqmDn3Yo_wBG3nEZ https://secure.na1.documents.adobe.com/verifier?tx=CBJCHBCAABAAlVhU_AyuXlANWfgIFqmDn3Yo_wBG3nEZ

EXISTING TREE INVENTORY

TREE NO. SPECIES SIZE (DBI-!) CONDITION STATUS/REMARKS TREE NO. SPECIES SIZE (DBI-!) CONDITION STATUS/REMARKS TREE NO. SPECIES I 1-!A,iTl-lORN 1211 GOOD PROTECT IN PLACE 31 PINE 8" GOOD PROTECT IN PLACE /,I MAPLE 2 1-lA,iTl-lORN 1211 GOOD PROTECT IN PLACE 32 PINE 11 11 FAIR PROTECT IN PLACE 1,2 LCNDON PLANE TREE 3 LINDEN 1011 GOOD PROTECT IN PLACE 33 SPRUCE 12' GOOD PROTECT IN PLACE 1,3 LINDEN 4 1-!A,iTl-lORN 1011 GOOD PROTECT IN PLACE 34 SPRUCE 12' GOOD PROTECT IN PLACE 1,4 LINDEN 5 LINDEN 1011 GOOD PROTECT IN PLACE 35 SPRUCE 12' GOOD PROTECT IN PLACE 1,5 LINDEN I, 1-!A,iTl-lORN 1011 GOOD PROTECT IN PLACE 31, SPRUCE 12' GOOD PROTECT IN PLACE 1,1, FIR 7 MAPLE 1011 GOOD PROTECT IN PLACE 37 SPRUCE 12' GOOD PROTECT IN PLACE 1,7 1-!ACKBERRY

8 OAK 8" GOOD PROTECT IN PLACE 3S PINE 10' GOOD PROTECT IN PLACE 1,8 1-!ACKBERRY

9 RU55IAN OLIVE 8" GOOD PROTECT IN PLACE 39 PINE 8" POOR PROTECT IN PLACE 1,9 FIR

10 PINE 8" GOOD PROTECT IN PLACE 40 PINE 8" GOOD PROTECT IN PLACE 70 PINE

II PINE 8" GOOD PROTECT IN PLACE 41 PINE 12' GOOD PROTECT IN PLACE 71 OAK

12 PINE 8" GOOD PROTECT IN PLACE 42 PINE 10' GOOD PROTECT IN PLACE 72 OAK

13 PINE 8" GOOD PROTECT IN PLACE 43 SEQUOIA 14' GOOD PROTECT IN PLACE 73 LCNDON PLANE TREE 14 PINE 8" GOOD PROTECT IN PLACE 44 PINE 14' GOOD PROTECT IN PLACE 74 LCNDON PLANE TREE

15 PINE 8" GOOD PROTECT IN PLACE 45 PINE 1111 GOOD PROTECT IN PLACE 75 SPRUCE

11, PINE 12" GOOD PROTECT IN PLACE 41, PINE 12' GOOD PROTECT IN PLACE 1. 1-lACKBERRY

17 MAPLE 1011 GOOD PROTECT IN PLACE 47 PINE 11 11 GOOD PROTECT IN PLACE 77 FIR

Ill MAPLE 1011 GOOD PROTECT IN PLACE 41l LINDEN 12' FAIR PROTECT IN PLACE 78 FIR 19 PINE 1411 GOOD PROTECT IN PLACE 49 PAGODA TREE 8" GOOD PROTECT IN PLACE 79 PINE

20 FIR 1311 FAIR PROTECT IN PLACE 50 PINE II,' GOOD PROTECT IN PLACE BO LINDEN

21 PINE It GOOD PROTECT IN PLACE 51 PINE II,' GOOD PROTECT IN PLACE 81 LINDEN

22 PINE 1211 GOOD PROTECT IN PLACE 52 LINDEN 10' GOOD PROTECT IN PLACE 82 PINE

23 PINE 1411 GOOD PROTECT IN PLACE 53 PINE 12' GOOD PROTECT IN PLACE 83 PINE

24 LINDEN It GOOD PROTECT IN PLACE 54 MAPLE 13' GOOD PROTECT IN PLACE B4 PINE 25 LINDEN 1011 FAIR PROTECT IN PLACE 55 LINDEN 10' GOOD PROTECT IN PLACE 85 LOCUST 21, SRUCE 12" GOOD PROTECT IN PLACE 51, PINE 12' GOOD PROTECT IN PLACE 80 LCNDON PLANE TREE 27 SRUCE 12" GOOD PROTECT IN PLACE 57 PINE 13' GOOD PROTECT IN PLACE 87 LCNDON PLANE TREE 28 SRUCE IZU GOOD PROTECT IN PLACE 58 PINE 13' GOOD PROTECT IN PLACE 88 LCNDON PLANE TREE

29 SRUCE 1211 GOOD PROTECT IN PLACE 59 MAPLE B" POOR PROTECT IN PLACE 89 LNDEN

30 SRUCE 8" FAIR PROTECT IN PLACE i>O MAPLE 8" GOOD PROTECT IN PLACE 90 LINDEN

SIZE (DBI-!) CONDITION STATUS/REMARKS TREE NO. SPECIES SIZE (DB~)

1211 POOR PROTECT IN PLACE 91 LINDEN 10'

1011 GOOD PROTECT IN PLACE 92 1-lAWTl-lORN 12 1011 GOOD PROTECT IN PLACE 93 LINDEN e"

1011 GOOD PROTECT IN PLACE 94 LONDON PLANE TREE 8"

1011 GOOD PROTECT IN PLACE 95 1-lAWTl-lORN e"

1211 GOOD PROTECT IN PLACE % 1-!ACKBERRY 13'

1011 GOOD PROTECT IN PLACE 97 1-lAWTl-lORN 8" 1011 GOOD PROTECT IN PLACE 9B 1-!A,iTl-lORN 8"

1011 FAIR PROTECT IN PLACE 99 1-!ACKBERRY 12'

8" GOOD PROTECT IN PLACE 100 LONDON PLANE TREE 8"

12" GOOD PROTECT IN PLACE IOI 1-!ACKBERRY e"

1211 GOOD PROTECT IN PLACE 102 LONDON PLANE TREE 9"

1011 GOOD PROTECT IN PLACE 103 1-lACKBERRY 8"

10" GOOD PROTECT IN PLACE 104 LONDON PLANE TREE 10'

1011 GOOD PROTECT IN PLACE 105 LONDON PLANE TREE 10'

10" GOOD PROTECT IN PLACE IOI, LONDON PLANE TREE 10'

1011 GOOD PROTECT IN PLACE 107 1-!ACKBERRY 10'

1211 GOOD PROTECT IN PLACE 100 1-!ACKBERRY 10'

1211 GOOD PROTECT IN PLACE 109 LINDEN 1111

1211 GOOD PROTECT IN PLACE 110 LINDEN 10'

1211 GOOD PROTECT IN PLACE Ill PINE 12'

4" GOOD PROTECT IN PLACE 112 PINE 14'

lo" GOOD PROTECT IN PLACE 113 LINDEN 10'

1211 GOOD PROTECT IN PLACE 114 LNDEN 13'

1011 GOOD PROTECT IN PLACE 115 LONDON PLANE TREE 9"

1211 GOOD PROTECT IN PLACE Ill, LONDON PLANE TREE 10'

1011 GOOD PROTECT IN PLACE 117 OAK 10'

1011 GOOD PROTECT IN PLACE 118 PINE 10'

1211 GOOD PROTECT IN PLACE 119 PINE 10'

1211 GOOD PROTECT IN PLACE

CONDITION STATUS/REMARKS

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE SCALE t NORTl-l ARROW

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

GOOD PROTECT IN PLACE

FAIR PROTECT IN PLACE

FAIR PROTECT IN PLACE 6] I I I

0 40 eo NORTI-I SCALE• 111 • ao•-0 11

A

I 11&0

=-= a:

f .... -C a:

l-a:

II.I z z Q

CD

0 , q'

CD

:z: = = u u, a:

Cl Cl w z z w :=i.::::

cw, en N

*'' " i t i 0 Design, Inc Landscape Architecture & Architectural Sile Design

1 058 E;;ast 21 00 South Salt Lake City, Utah 84106 office 801 . 4B7 . 49.23 fax 801 . 468 . 3046 www.arcsitiodesign.com date: Dec. 16, 2025 revisions

Existing Tree Inventory

SDOOO

Solt Lakt City Public Utirties Generol NQles - Updo1ed 07/1/207:5

1. COMPLIANCE:

ALL CONSTIM:TION AND MATERIALS 9-IALL BE IN ACCOOOANCE WITH THESE

CONTRACT DOCUK:NTS AND THE MOST RECENT EOIT~S Cf THE rDllOWHG:

THE ~TERNATlt:fiAL PLU~NG CODE. UTAH DRINKING WATER REGULATICNS, N'WA M.MIUAL Of STAND.&RD PLANS AND PEC:FlCAllONS, Af.lD SLC PUBLIC UTILITIES MOOFICATIONS TO APWA STOOARD PL.ANS AIO APPKMD MATERIALS ANO su;

PUBLIC UTILITIES APWA SPEOFICATIONS MODIFICATIONS. THE CONTRACTOR IS

RE()JIRED m ADHERE Tc'I All or THE AEIOV[-IIENTIONED IXX:Uli1ENTS ~LESS OH£RWIS[ NOT£□ AI..Jl M'PROVED ~ lfilffiG BY THE SALT LAKE arr DIRECTOR

OF PUBLIC UTILITIES.

2. COOR[)INATION·

THE CONTRACTOR IS RESPCNSE!I.E TO NOTF'f ALL APPROPliV,lE GO\ERN~ENT AND PRIVATE ENTITIES ASSOCIATED WITH THE PROJECT. THE Fa.LO~G t.tJST ll CONTACTED 48-HOURS PRK:fl TO CONSTRUCTICN AS APPUCf\llI TO THE

PROJECT:

PUBLIC UTILITIES:

BACKFLDW PREVENTION - -48.:Hi795

DEVELOPMENT RE\IEW ENGNEERING - -483-6781

IN~ECTICNS, PERMITS. CONTRACTS ill: AGREDJENTS - -483-6727

PRETREATMENT - 799--4002

STOOi.i WATER - -48J-6721

SLG l:t:PARTMENTS;

EN~NEERING - PIB.IC WAY PEINTS MIi ISSIES - 5J5-620J

EN(}NEERING - Sl.llOMSIONS - 535-6159

FRE □ EPARlMENT - 555-66!6

PEIMTS AND LKINSII«:- (BLDG SERVICES} - 5J5-7752

PLANNING AN□ ZONING - 535- 7700

TRANSPORTATION - 535-66.lO

All OTHER POTDHW.LY IMPr\ClED OOVERNING AGENQES OR ENTITES

All WATER USERS INVOLW:□ N WATER MAN 9-!UlOOIINS

APPLICABLE SEWER. WATER WJ IRAINAGE DISTRICTS

BWEST.tKES LOCATltK: ~R\IICES - 53.2-SOOD

COONTY RRE D[P,ij(:JMENT - 743-7231

COON TY FLOOO CONTROL - -468- zm

COONTY HEALTH DEPARTMENT - JBS--468-J91J

COONTY i=\JBUC WAY PERMITS - -468-2241

HCl..LAIJAY CITY - 272-!MSO

S,',LT LAKE COONTY HIGHWAY OCPAATMENT - 468-3'705 OR 458-2156

THE UTAH TRN\ISIT AUTHCftlTY FOR RE-R<JUTING SER'.lCE - 262-5626

Ur.ION PAOFlC RAILROAD CO., SlJPERINTOOENTS CfFl[I - 5ts-J400

UTAH DEPARTMENT or TRANSPORTATICN, REGICN #2 - 075--4810

UTAH STATE ENG11£Elt - SJB-7240

SCALE t NORT~ ARROW

6D I I I 0 40 eo

NORTI-I SCALE: I ii • eo;-o•

A

I lloO

1 SCHEDULE

PRI~ TO CONST!a.CTKJN 11-E <.'OITRACTOR 'Mll PRO\!CE:, AND 'MLL UPDATE AS CHANGES OCCUR, A CONSTRI.JCTICN SCHEDlli IN ACCIROAta IIIIH THE

SPECIFICATIONS ANO SALT LAKE CITY ENCKERINC CR SALT LAKE CO~TY

RE(lJLADS AS APPLICAB...E FOR 'IIOO(ING WITHIN THE Pl.ft_( WAY.

-4. PERijlT5, FEES ANO AGREEWENTS CONTRACTOR UUST OBTAIN All Tl-IE NECESSr'RY PER"9TS ANO ~EEMENTS MO PAY All APFUCABLE FEES PRIOR TO ANY Cc:NSTRUCTION ACTI\1TIES. CONTACT SALT LN<E ON ENGINEERING {301-5J5-620J) FOR PERWI~ AN□ INSPECTKflS REWRED F(R ANY WORK CCNCJJ:TED 1/ITHN SALT LN<E an'S F\JBLIC RK,HT- □F-WAY. APFUCABLI UTILITY PERl,ITS MAY INQIAJE MAINLNE EXTENSION AGREEMENTS ANO SEINCE CCNNECTION PERMITS. All un.m WORK MUST BE BON□m. All CONTRACTORS t.l.lST BE LICENSED TO WORK ON CITY UTILITY IMINS. OJNSTROCTICN ~HES WUST BE IN COUFU.w::E WITH THE UTAH PlllUTION DISCHAR<l: ELIWINATON SYSTEM (UPCES} STORW WATER PERMIT FIJl

CONSTRUCTI()I ACTI\4TIE'S (5511-692J). A aJPY OF ll-£ Prnt.trs STORM WATER POLLUTI~ PREVENTION PLAN MUST IE SUBlillTl[D TO PLBLC UTILITIES FOO RE\"IEW AN□ M'PROVAL. ADDITIONAL WATER OU&ITY AND ER<JSION CONlROL 1,£ASURES lilAY BE REOLIRED. THE C{NTRACTOR Y.JST ALSO CO.PLY WITH S&T LOO: art's ru»1 MIEEL OOOINANCE.

!i. ASPHALT AtO S(JL TESffiG THE CCNTRACTCR IS TO PROVIDE lilAASHALl »ID PROCTOR JEST DATA 24-HOORS PRIOR TO US:. CONTRACTOR IS TO ffiOVIDE CIN'ACTION ANI> OENSIT't' TESTING AS REIJJRED BY SALT LAKE CIT't' ENGINEERING, UOOT, SALT LOO: COUNT't' OR OIHER GDIIERNNG ENTITY. TRENCH BACKFlll MATERIAL AND COMPACTKlN TESTS ARE TO BE TAKEN PER APWA STANDARD SPEOFICATICNS, SECTION 330521} - BACK~WNG TRENCIES. m AS REOURID BY TIE SLC PROJECT ENGINEER IF NATIVE MATERIALS ARE USED. NO NATI'l'E MATERIALS ARE ALLOW::□ WTHIN THE PIPE ZOiE. Tl-IE MAXIMLM LIFTS F(R BACKFlLLNG EXCAVATICNS IS 8-INCHES. ALL MAT£RIALS AND COt.lPACTION TESTNC IS TO BE PERfORMED BY A L.&8 RECOGNIZED AND ACCEPTED BY SALT LAKE COUNTY PUBUC OKS AN□_,m SALT LAKE □TY ENIJNEERN:,.

6 TRAFFIC CDN IROL Atll HAUL ROUlES TRAITIC CONTRll WST COOHflM TO THE UOST OJRIENT EDITION or SALT

LN<E CITY TRM'FIC CONTRQ MANUAL - PART 6 OF CIMANUAL CN UNFORM

TRAFFIC CONTRII.. OE\"ICES FCJl SALT LAKE CDJNTY AND STATE ROADS. SI..C TRANSPOlTATICN MUST APPROVE ALL PRO.£CT HAUL RllJTES (001-535-6653}.

THE CCNTRACTCR MUST AL.9.'l ClliFOll,I TO LOOT, SALT LAKE COJNTY 00 OTHER APPUC>BLE GO\ERNNCi ENTITIES REOUIRElt'ENTS FOR TRAFFIC CONTROL

7. SURVEY CONTROL

CONTRACTOR UUST PRO\OE A REGISTERED LAtll SJR\EYOO Cfl PERSONS UNDER SUPERi.-iSICN CJ' A REGISTERED LAND SlRVEYOR TO SET STAKES FOR AUG~ENT ANO GRAOE OF EACH MAIN AND/00 fACILITY AS APffiO~. THE '5TAKE'5 SHALL

BE M~KE□ WITH THE HORIZ<tHAL LOCATICN (STATI!l'l) MO \ERTICAL LDCA~ (CRADE) 'MTH CUTS AND/OR FlllS TO Tl-IE IR>OE or THE MAN AND/OR FACILITY AS APPRO'i'ED. IN A.OOITION, THE CONTRACTOR A~/OR Sl.RVEVOR SHAll PR0'.'1DE TO SALT LAKE CITY PUil.iC UTUTIES OJT SHEETS rm□ OUT

DEMOLITION NOTES

COMPLETELY AND QEAll.Y SHOWING THE PERTtlENT IRHJES, ELEVAT~S ANO a.JT/FlLLS ASSOCIATED '111TH Tl-£ FIELD STAKING OF THE WAIN AND/IR FAClJTY.

THE CUT SHEET Fr:RU IS AVAL.ABLE AT THE ~TRACTS ANO AGREEMENTS CfFlCE AT MUG UllUTIES. ALL WAINS AND LATERALS NOT MEETING MINll,t.JM GM[( REOURENENTS AS '5PEClflED BY IJlDINANCE (R AS REOURED TO t.EET THE WINMUM REllJIR[O FLOWS OR AS APPR0'.£0 tlJST BE REMOVED ANO REcctlSTRUCTEO TO ~EET DESIGN GRAIi:. THE COHRACTIJl SHALL PROTECT ALL STAKES ANO MARKERS UNTL PUil.iC UTILITY SURVEYOOS COll1Pl.£TE FINAL ~EA~E~ENTS. THE COiTRACTOR 'fill II: RESPCNSIBLE FOR FURNSHNG, ldAINTAINNCi, OR RESTCRINCi All lilONLt.ENTS ANO REFERENCE II.ARKS J'i1THN THE PRO.ECT 9TE. OCPENONG ON THE LOCA~ or H PRO..ECT; CONTACT THE Cll.lNTY ~'IEYOR roo SECTION CCRNER 1,1(:NUijENTS (8Dl-468-202l!.}

~□/OR TH[ SALT LAKE CITY SUIMYCR {&ll-535-7973) FOR SA.LT LAKE CITY ldONUUENTS AND ca!STRUCTION REQUIUMENTS. ALL ElfVATICtlS 9--IALL BE REFEli£NCED TO SALT LAKE CITY DATUM U~ESS NOTED OTHERWSE ON THE .,,, B. AS"liAL T QJARANTEE THE CIJHRACTIR SHALL REMOVE, llSPDSE Cf, FURNISH AND PLACE PERMNIENT ASPHALT Ft:R SALT LAKE CITY ENrJNEERNG, UOOT, COUNTY, OR OIHER OOVERNWENT STANDARDS AS APPLl::ABLE TO THE PROJECT. 11-E C()ITRACTOR SHAll CUilR.6NTEE THE ASPHALT RESTIRATKJN FOR A PERKlO AS REIJJIREO BY

THE GQIJERNINC ENTITY.

9. TEUPOORY ASPHALT

f Tl£ IXfHRf\CTOR CHOOSES TO WCRK WITHIN THE FUIUC WAY WHEN HOT MIX ASPHALT IS NOT AVAILABLE. THE Gc:NTRACTCR MUST OBTAIN A.PPROVAL FROU Tl-IE APPROPRIATE GO\ffitlNG ENTITY PRICN TO INSTAWNG TEMPORNl:Y Asi:,-,ALT SI.JRFACN'.: MATERIM. WTHIN SALT LAKE CITY, MEN PERt.lANENT ASPHALT 11:CCKS AVAILABLI, THE roiTRACTOR SH,11.l REMO\£ THE TEldPIJlARY ASPHALT, FURr.lSH ANO NSTAl.l THE PERMAIENT A!':PHAL T. Tl-[ a:NTRACTOR SHAll CUNW--ITEE TH[ ASPHALT RESTCRATION r□R A PERIOD AS REOOIREO BY THE GD'IERNING ENTITY FRet.l THE Dr..TE Of CQ..PLED.

10. S~HY

THE GIJITRACTCR IS RESPCN~BLE HR All ASPECTS OF SAFETY OF THE PROJECT ANO SHAU. WEET ALL O!i-lA, STATE, COJNTY AN) OTHER 00\fflNNG

ENTITY IEOUIREMENTS

THE CC:tnRACTIR IS SOLELY RESPONSBLE FOR CONFCflMING TO LOCAL .AND FEDERAL CODES GO\ERNNG SHOOING ANO BRACING OF EXCAVATIONS Mll TRENCHES, AND FCR THE PROTECTION OF llt1i'KERS.

11. OUST CONTRO.

Tl-IE CIJORACTCR IS RESPCNSIBLE HR DUST CCNTRCL A.CCORllNG TO THE OOVffiNING ENTITY STAtllARDS. USE OF H'r'IJRANT WAT[R CR PUWPNG f'R(),4 OTY-DYINED CANALS CR STmM OOANAGE FACUTIES IS NOT ALLO\li£0 FOR OCJST CCtHRCt ACTIVITIES J'i1THOOT ~ITTEN APPROV,',L or THE PlllL~ UTLITIES

~RECTOO,

1 l DEWA T[RN:;

Ml. ~-SITE OCWATERINC ACTIVITIES WUST BE APPRO~O IN WRITIN!:; BY PUBLIC UTUTIES. PROPOSED OJTF.AI..L LOCATl()JS ANO ESTIMATED FLOW VOLUME CALCULA.11005 MUST BE SUBMlm□ TO PUlllC UTILITES FOR REVEW AND

I. CONTRACTOR IS RESPONSIBLE FOR GeTAINING NECESSARY JURISDICTIONAL PERMITS.

N"PROVAL. AOEQl}ATE li1EA~RE5 MUST BE T~EN TO REMOVE All ~DMENT PRIIR TOOISOiARGE. PUBLIC UTILITES MAY REOOIRE ADDITIONAL li1EASURES FOR

SEDIMENT CONTROL ANO REUOVAL

lJ. PRO.ECT LIMITS THE CIJHRACTIR IS REllllli£□ TO KEEP All CCNSTll.CIDi ACTIVITIES WITHN

THE APPRD\£0 PROJECT LIMITS. THIS INCWOCS, BUT IS OOT LIMITED TO, VEHICLI

Wl EQJPMENT STAGNCi, lilA.TERIAL STOOAGE ANO LMTS OF TRENCH EXCAVATIIN. IT IS THE CCtHRA.CT<:RS RESPOOSIIILITY TO OOTAIN PEIMSSION Wl/(IR EASEMENTS FROM lHE .&PPROPRIA IE WJERNNG ENTITY ANO/OR

INDMllJN. PRCPERTY OMER(S) FOR wrRK ffi STAGING OUTSIOC OF Tl£

~O.CCT L.MITS.

14. WATER. FIRE. SANITARY !i:WER .+.ND STORM LflAINAGE UTILITIES

A. INSPECTIONS -

IT IS THE CONTRACTOR'S RESPONSIBILITY TO SOIEDI.JLI ANY WATER, SEWER,

BACKFLOW AND DRAINAGE INSPECTION 4B-HOJRS N ADVANCE TO \HN NEEDED.

~TACT ~BJ-6727 TO SCHEOOLE INSPECTIONS.

8. OAUAGE TO EXISTING UTIUTES -

THE CCNTRACTffi IS RESPONSIBLE FCR REPAIRI~ ANY DAMAGE, CAUSED BY .&NY OOt[llTICN INCUJllNG SETTLENENT, TO DISTING UTILITIES FROU \\ORK PERFORMED AT OR NEAR EXISTit«: UTILIT[S. Tl£ CONTRACTOR SHALl TAKE ,'LL f.lEASlfiES t.EGESSARY TO PROTECT ALL DJSTING PI.B_IC Atll PRIVATE ROADWAY AND UTILITY FACILITIES. □AUAII TO EXISTING FAClLITIES CAUSED BY THE CCNTRACTCfi, NUST BE lif:PAIRED BY THE CONlRACTCfl ,l,.T HIS/HER EXPENSE, TO TIE SATISFAC'TION or H OIINER OF SAID FACIUllES.

C. UllLITY LOCATIONS -

COOTRACTOR WILL BE RESPCNSB.E fOR LOCATING AND AVOIDING All UTUTIES Mil ~RVICE LATERALS, Mil FOR REPARINC All OAMACE THAT OCCl.llS TO 11-E UTLTIE:S DUE TO THE CONTRACTOR'S ACTIVITIES. CONTRAClOR 15 TO IJERlfY LOCATION, DEPTH, SIZE. UATERIAL AN:l OOTSIDE DIAMETERS CJ' UTILIT[S IN THE flELD BY PDTHCI..N:; A t.lMUUU Cf 300-FEET AHEAD Cf SOIEDULEO CONSTRUCTICN N CIIDER TO IDENTrY POTENT1AL. COlfllCTS ,WJ PRIELEMS WITH FUTIJRE CCNSTRUCTION ACTI\4TIES, EXISTING UTILITY IN"CRMA.Tlrn CIITAINE□ rnou SLC PUBLIC UTILITIES' UAPS MUST BE ASSUMED AS ,ijlPROXIMATE Atll REOJIRNG flELD IJERIFlCATION. CONTACT BUE STAKES OR APFROPRIATE OVNER F'OR COIMJNICATKli LINE LOCATKliS.

D. UllUTY RELOCATIONS -

FOR UllUTY cctiFLICTS REl)JRINC MANLNE RELOCATIONS, TIE CONTRACTOR f.lUST NOTIFY THE APPLICAa..E UTILIT't' COMPANY 00 USER A MINIMUM OF 2'-\IIEEKS IN A.DVN-0::. A ONH\EEK MNlhlU~ NOTIFICATI~ IS REQUIRED FOR CONFLICTS REOUfilNG THE RELOCATION CJ' SEINGE LATERALS. ALL RELOCATIONS .&RE: SUBJECT TO APPROVN. FROM THE APf'UCABLE UTILITY Cet.lPANY Wl/OR

"'" E. Fla.D CHANGES -

NO ROADWAY, UTLITY ALIGtl.ENT OR GRADE CHANGES ARE ALlO\IEO fRIJJ Tl£

N"PROVED CONSTRUCTI~ PLANS/OOCUMENTS \IIITHOI/T ~TTEN APPROVAL FROU

2. IJ,JLESS OTHER l»IISE NOTED, ALL PAVING, l»IALLS, STRUCTURES, SITE FURNISI-IINGS, VEGETATION, ETC. SI-IALL BE PROTECTED IN PLACE,

3. ALL ITEMS NOTED TO BE 'REl"Vw'E0" SI-IALL BE PROPERLY ANO LEGALLY DISPOSED OF, UNLESS NOTED Ofl.lERl»IISE TO BE SALVAGED, RE-INSTALLED, AND/OR CONVEYED TO OWNER.

~- CONTRACTOR TO VERIFY LOCATION ANO DEPTl-l OF ALL EXISTING UTILITIES PRIOR TO ANY CONSTRUCTION OR EXCAVATION. PROTECT IN Pl.ACE ALL

EXISTING UN0ERGRO.JN0 UTILITIES. ANT ADDITIONAL COSTS INCURRED AS A RESULT OF CONTRACTOR'S FAILURE TO VERIFY LOCATIONS OF EXISTING UTILITIES PRIOR TO 6£GINHING Of CONSTRUCTION IN TI-IEIR VICINITY SI-IALL BE BORNE Bl' Tl-IE CONTRACTOR AHD ASSUMED INCLUDED IN Tl-IE CONTRACT. CONTRACTOR IS TO VERIFY COltlECTletj POINTS l»IITH EXISTING UTILITIES. CONTRACTOR 15 RESPONSIBLE FOR ANY DAMAGE CAUSED TO EXISTING UTILITIES AND UTILITY STRUCTURES TIIAT ARE TO REMAIN. IF CONFLICTS l»IIT!-1 EXISTING UTILITIES OCCUR, THE CONTRACTOR SMALL NOTIFY THE OWNER's REPRESENTATIVE PRIOR TO <DISTRUCTION TO DETERMINE IF ANY FIELD AD.lJSTMENTS 51-1ClULD BE MADE.

s. CONTRACTOR SHALL VERIFY ALL CONDITIONS IN THE FIELD AND REPORT ANY DISCREPANCIES TO THE OWNER'S REPRESENTATIVE.

REFERENCE SC~EDULE NOTES

COD!: D=SC!c.l?il ON

D51-10l..lTION: ?lc.OT5CT-IN-?L....i..C5

!DI-IOljl

I D1-10211

GONGR.ETE PAVINc:&

SITE FUR.NISHIN<S,5 (6ENC,HES,

TABLES 61KE RAC.KS, Sl<:,N5, ETC.J

QTY

D51-10l..lTION: CONV5Y TO OWN51c.

ID2-101l1

I D2-102 j1

DR.INKINc:& FOUNTAIN

PLAYGROUND EGUIPMENT

D51-10l..lTION: lc.51-10V5 AND DISCA!c.D

!DS-01j1 VE<:,ETATION (EXC.LUDINc:& TREES, PR.OTEC.T ALL TREES)

I D:3-0211 PA'T'<:,R.OUND 5URFAc.E TO 5Uec:&AADE

5,"l51 &f

! DS-O9 Ii Sl<:,N, INGLUDIN<:, C.ONGR.ETE SLAB AND FOOTINc:&S

• G'IJANTITY INFORMATION PROVIDED FOR

REFERENC-E ONLY. c.oNTRAC,TOR RE5PON516LE TO VERIFY ALL GlUANTITIES.

THE SLC PUBLIC UTILITIES DIRECTIR. Q-IAN-iB TO HYDRANT LOCATKINS AND~ flRE UtES UUST 11: REVE~O AND APPROVED BY THE SALT LAKE CITY OR SALT LAKE C()JNTY FfiE DEPARTMENT (AS WPUCABLE TO THE PRO.ECT) AND PUii.JC

UTUTIES.

F. F,JBLJC NOTICE TO PROJECTS IN Tl-IE PUBLIC WAY -

FOR APPROVED PROJECTS THE CONTRACTIR IS RESPOO~BLE TO PRD'IIDE ANO

~STRIIIJT[ WRITTEN NOTICE TO All RESIDENTS LOCATED WTHN THE PROJECT -6RE:A AT LEAST 72-IKI.JRS PRIOR TO ~SlRUCTION. WORK TO IE Cll'>lllJCTED ~THN CCMWERCIAL CR INDUSTRIAL NOS MAY REQUIRE A LONGER NDllFICATICN PERIOD AND AODITICNAL CCNTRACTOR COCflDINATICtl 'fl!H PRa'ERT't' OWNERS, THE YIRITl[N NOTICE IS TO BE APPl!O'.£D BY THE SLC PUII.K: UTILITIES PRO.£CT

ENGINEER.

G. PUBLIC NOTICE FCR WATER MAIN Sf-UT OOYf.lS -

THRCl.lGH M SI.C PIB.IC UTILITIES INPECTOR ANO WITH THE PUil.JC UTUTES

PRO.ECT ENGINEER APPROVAL. SLC PUBLIC UTILITES MUST BE CONTACTED AN□

WPROVE All WA lER MAIN 9-tUIDOYINS. ONII APPROVE□ THE CONTRACTOR lrtJST NOTIFY ALL EFFECTED USERS BY WRITTEN NOllCE A ~NIUUld OF

48-HOLRS {RESIDENTIAL) AND 72-HCXJRS (CCN.IERCIAL/INOCJSTRIAI..} PRIOO TO

THE WATER WAN SlfJT DO~. PIB.IC l.JTILIT[S MAY REOUIRE LONGER NOTICE Ft:RIOOS.

H. WATER N-JO S[\l,{R SEPARATION -

IN ACCCRDANCI 111TH UTAH'S IEPARTMENT or HEAi.Ti-i REllJLATIONS, A MINlldUf.l TEN-FOOT HORIZONTAL ANO 1.5-fOOT VERTIC/11... (WITH WAT[R CN TOP)

SEPARATION IS RE(;IJRED. IF THESE CONDITIONS CANNOT IE ~ET, STATE AN□

SLC PIB.C UTILIT[S APPROVAL IS REQUIRED. MlllllCHAL COOSTRUCTK>N t.EASI..RES WLL 11: REQURED FOR THESE CCNDITI~S.

SIILVAOC -

ALL ldETERS UUST IE RETURNED TO PUllJC UllUTI[S, ANO AT PUllJC UTIUTI[S REOL£ST All SA.I. VAGED PII{ N-ll/QR m11oos WST B[ RETUlNrn TO SI.C

PUBLIC UTILTES (-483-6727) LOUT£□ AT 1530 SOUTH WEST T£MPLE.

J. SHER MAIN ANO LAIERAL Cl'..NSTRUCTICtl REOUIREK:NTS -

SLC PIB.C UTILIT[S MUST APPRD'IE ALL SE\lfR CON~CTIONS. ALL SEWER LATERALS 6-INCHES ANO St.lAllER tl.JST W'T'E INTO THE MANS PER SLC PUBLIC UTILITIES REIJJ11i£MENTS. N.L 8-ltK:H i\ND LARGER SEWER lnNECTIGNS MUST BE PETITIONED FOR AT PUBLIC UTILTIES (48J-6762) AtO Cc:NNECTEO AT A MANHOLI. INSIII: l:flOPS IN MN--ll □LES ARE NOT Ml.OWE□. A WIMMUl,1 -4-FOIJT BURY DEPTH IS REOUfiED 00 ALL SE'M:R WANS Mil LATERALS. cct.lTRACTOR SHALL INST,',LL INW:RT COVERS IN ALL S['M:R MANIKlES 1111HN THE PROJECT AREA. CCNTRACTCfl TO PRCMII: AIR PRES~RE ITSTING OF SEWER MAINS IN ACCCffiANCE WITH PIPE MANUrACTURERS RECOUMENOA~S AND SALT LAKE CIT't' F\JBLIC UllLITIES REQUIREMENTS. All PVC S:'ffR MAIN AND LATERAL TESTNG 5HALl BE N ACCORDANCE \\1TH UNI-IELL UN-9-6-98 RECCMMENll:D PRACTICE FIR LOW ffiESSURE AIR TESTING or INSTALLED SE\1£R PIPE.

CONTRACTCR SI-IALL PROVIDE SEM:R LATER& WATER TESllNG AS REOUREO BY TllE SAi.. T LAK[ cm PUii.iC UTUTES PROJECT ENQNEER OR INSPECTIR A

SEPARATION 15 RE~IRED. If THESE CONDln:tlS CANNOT BE UET, STATE ANJ SLC PUBLC UTILITIES APPROVAL IS REQUIRED. MJOITIONAL COOSlRUCTION MEASlffS WLL BE REQUIRED FOO THE~ aJNOITIONS.

~VA.GE -

ALL UETERS ~UST BE RETURNED TO FUIUC UllUTIES, ANO AT F\JBUC UTILITIES REQUEST All SALVAGED PFE ANO/QR FITTINGS lilUST BE REilJRNEO TO SI.C

PIAlLIC UTLTIES (48J-6n7) LOCAl[D AT 15J(] SOUTll l'i{ST TEMPLE.

J. SEVIER WAIN ANO LATERAL CO\ISTRUCTION REQ.Jllif:MENTS -

SLC PUBLK: UTILITIES MUST APPRO\E ALL SEWER !XNNECOONS. ALL SEWER

LATERALS 6-INCHES ,\I{) g.j&.l.ER WUST W'T'E NTO TIE ldAINS PER SLC PUBLIC UTILITIES REQUfiEt.ENTS. '4...L 8-INCH AND LARCi:R SEI\ER COtl\ECTill'IS KIST

BE F£TITIONED FOR AT PUBLIC UTILTIES (48.J-6762) AN□ CON~CTED AT A

MANHOLI. 1N9DE DR<YS IN MANH(lES ~ NOT AllOllE□. A MINlrtJM 4-FOOT B~Y DEPTH IS REQUIIEO ON ALL SEWER MAINS /lHJ LATERALS. CONTRACTOO SHALL INSTALL ltM:RT COVERS IN ALL SE'fER MANHOLES WITHIN THE PRCl.ECT AREA. CONTRACTCR TO PR™OE AIR PRES9.JRE ITSTNG or SEWER MAINS N ACCOIIDNCE 11TH PIF{ N.wJFACTURERS 11:CCUMENDATICNS ANC, SALT LAIH CITY MUG UllUTIES REQIJREMENTS. All PVC S:YfR WAN ANO LATERAL TESTINC SHALL BE IN ACCCROAt-1:E WITH UN-BELL 1.N-B-6-9B RECCt,IIIEN[{O PRACTICE FOR LO'/f PR~E AIR TESTitK:; OF INSTAUID SEWER PIPE.

CllflRACTCR g,ALL PROVIDE SEWER LATERAi... WATER TESTNC AS REQJIREO BY

THE SALT LAKE CITY PUBUC UTILITIES PRO.CCT ENGNEER 00 INSPECTOR. A

MINIUU~ OF 9-FEET CJ' HEAD PRESSURE IS REWRED AS t.1EASURED IJERTICALLY FROlil TH[ HK:H PONT OF THE PIPELNE ANO AT OTHER LOCATIONS ALON!:; Tl-IE PFEL.t£ AS 1:t:TERMINEO BY THE SLC F\IBUC UTILITIES PRO.EGT ENGINEER CR INSPECTOO. TESTING Tl-£ !'rill BE NO LISS THAN AS SPEIJFIED F[~ THE AIR TEST DURATION IN TABLE I CN PACE 12 or UNI-B-6-98. N.L PIR::S SUBJECT TO WATER TESTING SHALL BE Fl.UY \1SIBLE TO THE INSPECTOR DURING TESTING.

TESTING UUST BE PERFORMED IN THE PRESENCE Cf A SLC PUBLIC UTUTES REPRESENTATII£. ALL \ll~BLI LEAKAGE MUST BE REPAIRED TO THE SATISFACTION

OF THE 3-C PUBLIC UTILITES ENG11£ER OR INSPECTOO.

K WATER AND FIRE ~AIN ANO SER\llcr C<lNSTIV:TW:X'I REOUREt.£NTS -

SLC PUBLK: UTILITIES MIJST APPRO\E ALL FIRE Atll WATER SERVICE CllmEC'OCtiS. A MINNJ.1 3-FOOT SEPARATION IS REQUIRED BETVfEN ALL WATER AtO FIRE ~Ri.-iCE TAPS INTO THE MAIN. A.LL CONNECTIONS MUST BE MADE liEEllNG SL.C PUii.JC UllUTIES f;£QUREl.£NTS. A 5-r□ OT MINl~Uf.l llJRY DEPTH (FINAL GRAOC TD TOP Of PIPE) IS RECIJRED ON All WATERftTRE Ul£S U~ESS OTHERl'ilSE APPRO\/i:O BY PUil.iC UTIUllES. WATER LNE THRUST BLOCK At-.0 RESTRANTS ARE AS PER SLC APPROVED [;{TAIL 1:RAWINGS AND SPECIFICATIONS. Ml EXPOSED NUTS »m BOLTS WLL IE !DATE□ WIH CHE~ON FIil GREASE PWS MNIWUW a IIIL IHCKNESS PLAST~ PRO\IIOE STANLESS STEEL NUTS, BDLTS Nil□ WASHERS FOO HIGH CROUNDWAT£R/ SAMATEO Ct'INOITIONS AT FlANCiE FITTir,,;;s, ETC. All WATERLINES INSTALLATIONS AND TESTir-«; TO BE IN ACCORDANCE WITH A.W#A SECTK:tiS C600, C601, C651, C206, C200, C90(], CJ03 A'INIA MMIU,'l M11 Mil A.LL CTHER NlPUCABLE AWNA, UPWS, ASTM ANO ANSI SPECIFlr.ATIONS RELEV»lT TO THE INSTALLATION ANO COUPLED OF THE PRMCT. At.ENOL£NT TO SECl'O, C600 SECTION 4.1.1; DOCUWENT TO READ

MNIMUM TEST PRESSURE SHALL NOT BE LESS THAN ZOO P.SJ. GAI.KiEO TO A HIGH POINT OF !HE PIPELINE BEING TESTED. AI..L MATERIALS USED fOR WATER\lrRKS PROJECTS TO 1£ RATED Fill:: 150 P_S.I. WINNUM l'PEltA.TNC PRESSURE. CONlRACTOR IS TO INSTALL 1/A TER SERVICE LINES. METER YCt<ES AAD/Cll ASSEMBLIES Mil ~TER BOXS WITH UDS LOCAlEO AS N>PROVED IJ',.I THE PLANS PER APPLICABLE PUBLIC UTILITIES DETAIL ORAWNGS. METER BIDfS ARE TO BE Pl.ACID IN THE PARK STRIPS F{RFt:NOICLL.AR TO THE 1/AHRMAIN SEINII Tf\P CCMECTIOO. All WATER UETERS, CATCH BA9NS, CLI»IOUT BOXES, MANH(lES, OOl.BLE CIECK YALVE [)[f[CTOR ASSEWBLIES, REDUCED PRESSURE DETECTOR ASSElfiJES AND BACKFLO'fl PREVENTION DEVICES lrtJST BE LOCATE□ oornlE a= All APPROACHES, DRIVEWAYS, PEDESTRIAN WALKWAYS ANO

OTHER TRAV[LED WAYS UNLESS OTHERWISE: APPROVED~ PLANS. BACKROW

PREVENT ORS A.RE RECU11i£□ CN ALL IRRKiA TION AND FIRE SPRINKLNG TAPS PER PUBLIC UTILITIES Atl) SLC RRE DEPARTMENT REQUIREMENTS. CONTRACTOOS SH,',LL INSl,'ll Bf\CKFLO'fl' FRE\ENTION DEVICES ON FRE SPRNKLER CONNECTIONS. OOUBLE CIECK VALVE ASSEt.tlLES SHALL II: INSTALLED OI

CLASS 1, 2 AND J SYSTEMS. REDUCED PRESSURE PRNCPLE VALVES 9--IALL BE

INSTALLED ~ Q.ASS 4 SYSTEf.l'S. AI...L FIii£ SPRNKLING BAQ<FLOW AS!c:UII..IES SH,',LL CW-01.M TO ASSE STANDARD 1048, 1013, 1047 AND 1015. Tl-[

CONTRACTOR S:-IALL BE RUPl)l~BLE TD PERFCRM BACKFLDW PREVENTION T[Sr.i

PER SALT LAKE CITY STANDARDS ANO SUBMIT RESJLTS TO PUBUC UTILITIES. ALL

TESTS MUST BE PERFORUED /lHJ SJBUITIEO TO PUil.JC UTILITIES l'IITHN 10 □AYS OF INSTALLATION OR WATER TURN-ON. BA[l(FLDW TEST F~US >RE AVAILAELE AT F\JBLIC UTILITIES' CCJ-lTRACTS ANO AGREEWENTS CfFICE. BOTH PUBLIC Atll PRIVATE Sffi\llCE LINE MATERIALS MUST BE RECORDED 'MIEN

AVAILAELE THRIJ..K,H THE NCRMAL SCOPE OF WORK. LEAD SEINCE LNES, LEAD

CONNECTORS I.E. PIGTAILS. SNCllT5. ANO CiOOS:NECKS, WJ/OR GALVANIZE□ SER\1CE LNES lHA.T IS OR Wf.S E't£R DDWNSM"-1 OF LIAD PIF{ MUST IE R[WO\-£D N-ll lEPLACEO '11TH APPROl{I) MATERIALS. THE OTY t.t.JST IE NOllF[O 'MIEN IHESE WITERIALS ARE DISCOVERED t.t.4EDIATELY, FOLLOW UP IS REQUREO FOR ANY Of THESE REllACEldENTS BEFORE SERVICE IS RESTCflEO..

REOUREMENTS INCWOE: PROVIDE FLUSHING NSTRIJCTIONS TO THE CUSTCllER, OEU\/i:RY IF A FlLTER APPROVED TO REMOIJE LEAO, AND PROVIJE NOTIFICATKNS IN□K:ATING THE HEALTH EFFECTS fI LEAD AND STEPS TO MITGATE LEA□ IN

DRNKING WATER.

L m£RAL WATER, SE'IER ANO STCRM ORAN REOUIREt.ENTS -

ALL WATER, rlRE AND SEWER SER\11IS STUBIED TO A PROR::RTY IIUST BE USED OR WATER AtO FIR[ !IR\IICES MUST IE KILLED AT THE MAIN AND SEWER LATERAI..S CAPPED AT THE !:£VIER t.lAIN PER PU9LIC UTILITIES REQUIRH.ENTS.

ALLOWABLE SERVICES TO BE KEPT 'Alli BE ~ OETERIIINED BY THE F\AIUC UTILITIES PRO,ICT ENQ1£ER. All WATER AND FRE !i:RVICE KlllS A.NO SEWcR LATERAi.. CAPS ,ij(:[ TO BE KUED AND C>PPEO AS OETERMNEO ANO VISUALLY W:fflFlEO BY THE Ct-I-SITE RllUC UllLITIES INS~CTIR All MANHClES, HYDRANTS, VALVES, Q.EAN-OUT BOXES, CATCH BASINS, METERS, ETC. t.tJST BE RAISED OR LO\ICREO TO FNAL GRI{)[ PER Pl/BLIC UTILITIES STANDARDS AND IN!FECTOR REllUIREMENTS. ~CRETE CCl.LARS MUST BE C[NS~CTEO ON All MANHOLIS, a.EANllJT BOXES, CATCH BASINS AND VAL'IES PER PUBLIC UTILITIES STANDARDS. ALL MANHlli, CATCH BASIN, OR CLEANOUT BOX CCNNECTIONS t.t.JjT BE IMO[ VIITH !HE PFE an fW::tl 111TH THE INSIDE OF THE BOX AND

,. ALL CONSTRUCTION SIGNAGE, BARRICADES, TRAFFIC CONTROL DEVICES, ETC., SHALL CONFORM TO THE LATEST EDITION OF THE M.U.T.C.D.

CONTRACTOR l»IILL MAINTAIN SUCJ-1 SO Tl!AT THEY ARE PROPERLY PLACED AND VISABLE AT ALL TIMES.

1. CONCRETE PAVB"IENT ANO CURB ANO GUTTERS SMALL BE OEMOL151-1E0 TO Tl-lE NEAREST CONTRACTION JOINT, MATClllNG PLAN AS CLOSELY AS

POSSIBLE.

6, CJl,IHER'S REPRESENTATIVE SI-IALL BE CONSULTED BEFORE ANY HCIR1' SI-IALL ca'IMENCE.

q_ Tl-lE CONTRACTOR 15 RESPONS161.E EQR MM:!IIAl!:l!!'lc; EX15Tl!'lc; IRRlc;ATIQ!i 5Y5TEt! ~ITHl!i Tl-lE PROJECI 51:QeE QF WORK C1!.IRl!'lc; CQ!!l5TRUCIIQ!'l •

REFER TO NOTES ON IRRIGATION PLANS

I I

GROOTE□ 00 5EM.ED AS REQUIRED BY THE PUBLIC UTILITIES INSPECTOR. ALL

MANHIJLI, a.EANllJT BOX 00 CATCH B~N OISCONNECTICNS UUST BE REPAIRED Atl) GROOTID AS REllJIRED BY THE ON-SITE PUBLIC UTILITIES INSPECTOR.

C~TRACTCR SHALL NOT ALLOW ANY GlOUNDWATER 00 OCBRIS TO ENTER THE NEW OR EXISTING PIPE IJJllNG CCNSTRUCTIOO. UTILITY TRENCrlNG, BACKFILL.

At-.0 PIPE 201£ AS PER SLC PUil.iC UTILITIES, ®UTILITY INSTALLATION DETAIL.'

M. STRE[lLIGHTS

ALL WORK SHAU. BE INSTAUfO IN ACCl'.mANCE WTH lHE UOST a.JRRENT SAI..T LAKE CITY STANDARDS AND N.E.C. (NATIONAL ELCTRICAL C<lOC. A STREET UGHTm PLAN SOOWING 'tilfflNG LOCATION. WfilNG TYPE, VOLTAGE, P<JIIER SOORCE LOCATION, GOODU T SIZE AN□ LOCATION 9-IALL BE SlJBMI TTID TD SALT LAKE CITY AND IE AFflROi.ID PRIOR TO CONSlRUCTICN. NO OEVIATICN IF STREETLIQH, PULL BOXES. OONNTS, AND ETC. LOCA.11005 9-IA.LL BE PERi-lTTED WITHOJT PRIOR ~TTEN APPROVN. FRal THE STREEGHT UCHTING PROGRAM MANIIR 00 HIS/HER REPRESENTATIYE. STREETI..JGHT Pll.ES ~All NOT BE INSTALlED \IIITHN 5 FEET or A FIRE HYDRANT. TH[ LOC,1,.TION Sl-1ALL IE SLX:H THAT IT DCl:S NOT HINDER THE OF£RATIIN OF THE FIRE HYDRANT M{I WATER LINE IPERATION VAL YES. SIHEETLIGHTS ANO SlREETUGHT POLES SH,l,.LL N:)T BE INSTALlED \IIITHN :> FEET FROM ANY TREE. l-tll~ ~ITTEN APPROVAL IS

RECEIVED FROW !HE STREET U'JHTING PROGRAM MANAGER. BRANCHES MAY NEED

TO IE PRUNED AS OCIERMINEO BY THI INg:JECTOR IN DE mn AT THE TIME or INSTALlATION. STREEILIGITS SHALL NOT BE INSTALLED WITHIN 5 FEET FROill THE EDGE Of ANY OOl~AY ANTI-SEIZE LUIRICANT SHAl.l IE USED ON ALL COYER Bil.JS ANO mouMJ BOX BOLTS. ALL EXISTING STREET LllllTING 9--IALL REMAIN OPERATI[NAL Ol.lllNG CINSTRUCTION UNLESS APPROVED IN W!aTING BY DE STREET LIGHTIN ffiOCRAM MMIA.CER. r APPROVED llANS REQUIRE REIKJVAL OF STREETLIGHT PCUS OCJRN:. CONSTRUCTIOO Tl-IE CIMRM:TOO SHALL BE R[SPCNSl3LE FOR Tl£ Pll.ES 'fllilLE THEY ARE omm THE Pll.ES !i-lALl BE STORED IN A SEllJlE LDCA.llON AND RAIED OFT THE CRllJNO. PICTUll:S !:l-lALL BE TAKEN BEFCRE TIE POI.ES ARE REMO\ED TO DOCUMENT THE COtlllTIIJ,I OF THE POLES BEFffiE THEY WERE REMOVED. PICTURES SHALL EC SENT TO THE CITY. COflRACTOR SHALL ENSURE THE POLES ARE IN SIMI.AR c«iOITION WHEN

RESTORED TO THEIR OOIIJNAL LCDATIONS IF THE APPROVED PLANS REQUIRE

PERMMNT REMOVAL l1' SRITUCI-IT POLES THE CCtHRACTOR SHAl.l C~OINAIE SALVAG[ ,l,.tll/QR DISPOSAL OF POI.ES, Fl>:MES, Mll LIGITS WITH THE STREET UGHllNG PRO:.RMI MANM;IB, ANY STRUCT\JI: Sl>CH AS BLOCK WAllS, O,AIN Uttc: FENCIS, RETANING WALLS, ETC. 9-!All LEAVE A MINIUUU (f

EIGHTEEN (18} INCIES TO THE FACI (f THE STREETLICHT Pru ON All SOES.

ALL SERV1CE POINTS 9--IALl BE COtmlNATED l'IITH ROO<Y MOJNTAIN POWER AND \\tlENE\£R POSSEILE EE LOCAlED 1£AR THE CENlER OF THE CIRO.HT, ~RV(E PllNTS g,ALL BE SHCM'N ON THE PLN>IS lllTH A ~JHATIC FROM ROCKY MOUNTAIN POllER. P<ll.E LOCATICNS "5 Sl!OWN ON THE APPROVED PLANS MAY BE ADJUSTED IN THE FIELD BY DE STRET UliHTING PROGRA~ 11,1,.NAGER A HE TIUE OF INSTAI..LATION AT NO l>D~OOML COST TO THE OTY. IT SHALL BE REQUIRED THAT IN TIE i\BSENCE OF AN EXISTING w:BABLE ORGUIT TO ATTAQ-1 TO, THAT Ml INSTALLATIONS SHALL REQIJRE A NEW SER\1CE FIR O~RATICN or Tl-IE CIRO.HTS. N THIS CASE THE OEVEI..Ci'ER AND OR HIS ENG1t£ER SHALL Cc:NTACT ROCCKY MOUNTAIN l'O'O FOR INSTA.LLAllON Of NEW SER\!CE.

\\tlENIJER THERE IS AN OVERHEAD UTILITY THAT MAY CONFLICT WITH THE

B KEYPLAN

INSTALlATION FO THE SlREETLIGHT CIRCIJTS Mll/Cft STRE[nJ()IT POLES, THOSE CONfl.JCTS MUST IE RESClYED BETll£EN THE OE'.£LCFER »lO 11-E UTILITES INVOL\.£0 ECFOOE THE STREETLO-IT BASES ARE CONSTRUCTED AT NO EXPEN!i:

TO ll-£ CITY Cfl ROCKY MO.INT AIN POWER. THE RESQUTION MUST BE APPRCMO BY Tl£ CITY AND ROCKY MOJNTAIN POWER.

All MUC STREET UC11TS SHALL REMAIN OPERATIONAL lHRCU}IQUT TIE ~SlllUCllON IF lHIS PRO.ECT IF ANY

DAWAGE HAPPENS TO A STREET UGI-IT, THE CONTRACTCR WU

IE REQURED TO FlX THE STREETUllH TO MEET TIE CURRENT SLCDPU STAND-'ROS AT THE OWtER'S [)PENSE.

Trench Zone Iceocb lone Hittn:lal

Stabilirat ion

2-locll mlnu5 - Grarular 11,a;;idll Borrow (A.PW"- J I 0$ IJ) N°'e: MaleNII must be flee of slag or f!!C'/'Cled aspha•.

Ha1erlill car> be 2· 1ndl ml.--...S ~I n,m ..,.,ten.lll elm zoor Matedal <1 r alpgxc too· t:1 •h• n1-, Dry amditioni, - GrcKle "" UTOC (.I.PWA l2 11 2)) > Wee C()tl(/J(Jol>s - 2• mlnu5 $ewe! r(X~ (APW" JJ 05 13) • NOl:ol! : MMnlal mun be lree ol :1w;i or r«:'(d!'d asphiltt.

Slabillullon Matmal (:tlj1d:t 6" below ah.el 2" mlnu• _.,.., rcxK (AJIWA 31 OS 13) N°'e: Hat.ol!rlal must be !tee ol slag or ra:ycied as:phall

Table I - ,>ipe zOr'\e matl!!rial and r'rlil\ill'lunl pipe .i:Ol'II!! width.

Pll)fl Matttlal Pipe Zone Materillt Mfr.. PlrteZ- f"" Wklth 'T• ..,, J 4" mlru5 wdlolilded • T ... oo•--24• , 36,· HOPt:-N12 '114" mlnu1 wetl'1rilded 1 T .. •00 .. 24" ~ 36" o, 'lf4" mlru1 w81nr.med • T.,. • 00 .. 24" ~ 36" Con<~M 3/4" mlrn1 wetl '"'"" . r,. - oo .. 2~- • 3fi"

I ~!er plPf" In tre~h.

2. VMl!l!IOM mu,11; be llPPfDlll!d In !ldvance by Ctilel Eng Ille!!,.

3. 2" m1nu1- -r rock ean be u~ In,_ below water table wl'oell approved In a,d,q,n,;,e- by Chief f ng1.._-,

4. OUl~e dl.arnl!lMaf I~ ~lpe.

5. 2· min.,1, Mil!enal rot p@,IMltted wn 11VC or HOPE pjp,!!.

C

--VSD101 '\ SD103 ~.SD102' ., ~

~ V_,,...--

~106 SD105~ l r

CD

q' a: CD

C :z:

A. = .... = u -C u, a: .. a: I- Cl a: >- Cl

II.I w z z z z w 0 :=i.::::

cw, Q 0 en N

*'' " 1 t 1 0 Design, Inc Landscape Architecture & Architectural Sile Design

1 058 E;;ast 21 00 South Salt Lake City, Utah 84106 office 801 . 4B7 . 49.23 fax 801 . 468 . 3046 www.arcsitiodesign.com date: Dec. 16, 2025 revisions

Overall Site Demolition Plan

SO100

REFERENCE SC~EDULE NOTES

CODE: DE:.sCl<IPTION

CE:MOL.ITION: Pl<OTE:CT-IN-PL.,A.CE:

I DI-IOI ~

!Dl·I02jl

GONGRETE PAYINCS.

SITE FURNISHINCS,S (BENGHES,

TA61.ES 61KE RACKS, SICS,NS, ETGJ

DE:MOL.ITION: CONVSY TO OWNE:R

!D:2·1O1!] DRINK.ING- FOUNTAIN

I D2•10211 PL.A'l'G-ROUND EGUIPMENT

DE:MOL.ITION: l<E:MOVE: AND DISCAl<D

! D5-0I ~

! D5-O:2 IJ

! D5-05jl

YEG-ETATION (EXGI.UDING- TREES,

PROTEGT AL.I. TREES)

PA'l'G-ROUND SURFACE TO

SU6G-RADE

SIG-N, INC.L.UDING- C.ONC.RETE SI.Ae

AND FOOTING-S

t:+:+:~ ~I

I I

I I

SCALE t NORT~ ARROW A

0 10 20 40

NORTI-I SCAL.E,

DEMOLITION NOTES

I. CONTRACTOR IS RESPONSIBLE FOR GeTAINING NECESSARY JURISDICTIONAL PERMITS.

2. IJ.JLESS OTMER li'IISE NOTED, ALL PAVING., li'IALLS, STRUCTURES, SITE FURNISI-IING.S, VEGETATION, ETC, 51-lALL BE PROTECTED IN PLACE,

3. ALL ITEMS NOTED TO BE 'REl"Vw'E0" SI-IALL BE PROPERLY AND LEGALLY DISPOSED OF, UNLESS NOTED 011-IERll'IISE TO BE SALVAGED, RE-INSTALLED, AND/OR CONVEYED TO OWNER.

~- CCJNTRACTOR TO VERIFY LOCATION AND DEPTM OF ALL EXISTING UTILITIES PRIOR TO ANY CONSTRUCTION OR EXCAVATION. PROTECT IN PLACE ALL

EXISTING UNDERGROUND UTILITIES. ANT ADDITIONAL COSTS INCURRED AS A RESULT OF CONTRACTOR'S FAILURE TO VERIFY LOCATIONS OF EXISTING UTILITIES PRIOR TO BEG.INHING Of CONSTRUCTION IN TI-IEIR VICINITY 51-lALL BE BORNE BY Tl-IE CONTRACTOR AND ASSUMED INCLUDED IN Tl-IE CCJNTRACT. CONTRACTOR IS TO VERIFY CONNECTIQ,j POINTS l'IITM EXISTING UTILITIES. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED TO EXISTING UTILITIES AND UTILITY STRUCTURES TMAT ARE TO REMAIN. IF CONFLICTS li'IITM EXISTING UTILITIES OCCUR, Tl-IE CONTRACTOR SI-IALL NOTIFY Tl-IE Ol'INER's REPRESENTATIVE PRIOR TO CONSTRUCTION TO DETERMINE IF ANY FIELD AD.1JSTMENT5 SJ.IOULD BE MADE.

S. CCJNTRACTOR SI-IALL VERIFY ALL CONDITIONS IN Tl-IE FIELD ANO REPORT ANY DISCREPANCIES TO Tl-IE OWNER'S REPRESENTATIVE.

I I

I I I I

I -I

I

I

I

PROVIDE AIR SPADE EXCAVATION

l'IITMIN EXISTING TREE 'PRZ' •

REFER TO TREE PROTECTION DETAIL

ON SI-IEET SD50I, DETAIL·B

I

I I I

I I

I I

UNLESS OTMERll'IISE NOTED, ALL PAVING., SITE FURNISl-lli'IG.S (BENCIIES, TABLES BIKE RACKS, SIG.NS, LIGMT POLES, ETC.), UTILITY EQUIPMENT, TREES

AND VEGETATION SI-IALL BE PROTECTED IN PLACE

I I

I I I

' I 't, I I f ' f I I I I I

' I ,.. /

I ' I \ I I

I I

I

/ y \ f f

6. ALL CONSTRUCTION SIGNAGE, BARRICADES, TRAFFIC CONTROL DEVICES, ETC., SMALL CONFORM TO Tl-IE LATEST EDITION OF Tl-IE M.U.T.C.D.

CONTRACTOR li'IILL MAINTAIN SUCII SO Tl-lAT TME'f ARE PROPERLY PLACED AND VISABLE AT ALL TIMES,

7. CONCRETE PAVEMENT AND CURB AND GUTTERS SI-IALL BE DEMOLISJ.IE0 TO Tl-IE NEAREST CONTRACTION JOINT, MATCIIING PLAN AS CLOSELY AS

POSSIBLE.

6, OJ,IHER'S REPRESENTATIVE SMALL BE CONSULTED BEFORE ANY HORI; SJ.IAL.L COMMENCE.

q_ Tl-IE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING EXISTING IRRIGATION SYSTEM WITI-IIN Tl-IE PROJECT SCQPE OF WORK DlJRING @ISTRUCTION •

REFER TO NOTES ON IRRIGATION PLANS

B

I I

I --- I

I I

I

KEYPLAN

I

I I I I I I I I I I I I I I I I I

N T""

C U)

I-w w

I ::c U)

I w w

I U) w z -..J .~

I !;;: 1 I :E

I I I I I I

I I I I

17' C l r

I ,~ ir..n • . ., .. $ .. ,,,,..,, 1· 1 -..... ~ri:.

,,;,_ '"~' ,.1,, ri.'

CD

q' a: CD

C :z:

A. = .... = u -C u, a: .,_ a: I- Cl a: >- Cl

II.I w z z z z w 0 :=i.::::

Q cw, en N

*'' " i t i 0 Design, Inc Landscafie Architecture & Architec ural Sile Design

1 058 E;;ast 21 00 South Salt Lake City, Utah 84106 office 801 . 4B7 . 49.23 fax 801 . 468 . 3046 www.arcsitiodesign.com

C ric J. P date: Dec. 16, 2025 revisions

Site Demolition

S0101

I

I I I I I I I I I I I I I I I -I

,;; ~ -C l ' ti)

1- 1 W w

J

Hj I tn I w z -...J ~. ~.

:E I

I I I I I I

I I I I I

I I

SCALE t NORT~ ARROW

NORTI-I SCALE,

I ' I \

I \ I \ I \

I I

I I -\ I \ I /,,.

' I ; \ I

', I / .,,.,,,.

/ 'I---. --- , I

I I I I

I , ' ; I ;

I I I I

/ I

; ' , I

REFERENCE SC~EDULE NOTES

DE:SCl<ll='TION

DE:MOI..ITION: Fl<OTE:CT-IN-?t.AC5

I DI-IOI ii !Di-102!!

CONGRE:TE: PAVING,

SITE: FURNISHING-S (eE:NGHE:S, TABLES BIKE RAC.KS, Slc;,NS, ETC,J

DE:MOI..ITION: CONVE:Y TO OWNE:I<

! D2-101 II DRINKING, FOUNTAIN

I D2•102 II PLA'l"'c;,ROIJND EQUIPMENT

DE:MOI..ITION: l<E:MOVE: AND DISCAl<D

VE:,:S,ETATION (EXGLUDING- TREES,

PROTEC. T ALL TRE:E:S)

I D5•02 h PA'l"'c;,ROUND SURFAC.E TO

SUB6RADE:

I D5-0'3 11 Slc;,N, INGL.UDING, C,ONGRETE SLAB

- AND FOOTING,S

f:+:+:1 flJwl

PROVIDE AIR SPADE EXCAVATION

i'IITMIN EXISTING TREE 'PRZ' •

REFER TO TREE PROTECTION DETAIL

ON SMEET SDSOI, DETAIL-B

UNLESS OTMERl'IISE NOTED, ALL PAVING, SITE

FURNISMINGS (BENCMES, TABLES BIKE RACKS, SIGNS,

LIGMT POLES, ETC.), UTILITY EQUIPMENT, TREES

AND VEGETATION SI-IALL BE PROTECTED IN PLACE

I I I I

I

I I

I I I I I I

I I

I I I I I I

' ' ' - ' ~===,..Ii; , ',--~----s;_--,' ~Y7\II/ITT!\!J~

A

I

KENNEDY DRIVE

( I I

-----------------------------MATCH LINE SEE SHEET SD106

DEMOLITION NOTES

I. CONTRACTOR 15 RESPONSIBLE FOR GeTAINING NECESSARY JURISDICTIONAL PERMITS.

2. L.t.JLE55 OTMER i'IISE NOTED, ALL PAYING, NALLS, STRUCTURES, SITE FURNISMINGS, VEGETATION, ETC. SMALL BE PROTECTED IN PLACE.

3. ALL ITEMS NOTED TO BE 'REl"Vw'ED" SMALL BE PROPERLY AND LEGALLY DISPOSED OF, UNLESS NOTED OTMERl'IISE TO BE SALVAGED, RE-INSTALLED, ANO/OR CONVEYED TO Oi'INER.

~- CONTRACTOR TO VERIFY LOCATION ANO DEPT!-! OF ALL EXISTING UTILITIES PRIOR TO ANY CONSTRUCTION OR EXCAVATION. PROTECT IN PLACE ALL

EXISTING UNDERGRO.JND UTILITIES. ANT ADDITIONAL COSTS INCURRED AS A RESULT OF CONTRACTOR'S FAILURE TO VERIFY LOCATIONS OF EXISTING UTILITIES PRIOR TO BEGINHING Of CONSTRUCTION IN TI-IEIR VICINITY SMALL BE BORNE BY Tl-IE CONTRACTOR AHO ASSUMED INCLUDED IN Tl-IE CONTRACT. CONTRACTOR 15 TO VERIFY CONNECTIQ,j POINTS ~ITM EXISTING UTILITIES. CONTRACTOR 15 RESPONSIBLE FOR ANY DAMAGE CAUSED TO EXISTING UTILITIES AND UTILITY STRUCTURES TMAT ARE TO REMAIN. IF CONFLICTS ~ITI-I EXISTING UTILITIES OCCUR, Tl-IE CONTRACTOR SMALL NOTIFY Tl-IE OHNER's REPRESENTATIVE PRIOR TO <DISTRUCTION TO DETERMINE IF ANY FIELD A0.1JSTMENT5 51-!ClULD BE MADE.

S. CetjTRACTOR SMALL VERIFY ALL CONDITIONS IN Tl-IE FIELD AND REPORT ANY DISCREPANCIES TO Tl-IE Oi'INER'S REPRESENTATIVE.

6. ALL CONSTRUCTION SIGNAGE, BARRICADES, TRAFFIC CONTROL DEVICES, ETC., SMALL CONFORM TO Tl-IE LATEST EDITION OF Tl-IE M.U.T.C.D.

CONTRACTOR NILL MAINTAIN SUCJ-1 SO Tl!AT TllEY ARE PROPERLY PLACED AND VISABLE AT ALL TIMES.

7. CONCRETE PAVB"IENT AND CURB AND GUTTERS SMALL BE DEMOLISMED TO TllE NEAREST CONTRACTION JOINT, MATCMING PLAN AS CLOSELY AS

POSSIBLE.

6, ~ER'S REPRESENTATIVE SI-IALL BE CONSULTED BEFORE AH'!' HORI; SI-IALL ca'IMEHCE.

q_ Tl-IE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING EXISTING IRRIGATION SYSTEM WITMIN Tl-IE PROJECT SCQPE OF WORK DlJRING @ISTRUCTION •

REFER TO NOTES ON IRRIGATION PLANS

B KEYPLAN

I I I I I .,.

I C

CD

q' a: CD

C :z:

A. = .... = u -C u, a: ..

a: I- Cl a: >- Cl

II.I w z z z z w 0 :=i.::::

cw, Q 0 en N

*'' " i t i 0 Design, Inc Landscape Architecture & Architectural Sile Design

1 058 E;;ast 21 00 South Salt Lake City, Utah 84106 office 801 . 4B7 . 49.23 fax 801 . 468 . 3046 www.arcsitiodesign.com date: Dec. 16, 2025 revisions

Site Demolition

S0102

-C tn

- 1-i W w ::c

- tn w w tn w

\ ~ I

I :E I

I

I I

I I

I I I I

I I I ,, ' I \

I ' I ', I I I I

I I , I

SCALE t NORT~ ARROW

NORTI-I SCALE,

A

REFERENCE SC~EDULE NOTES

CISSCRIPTION

!DI-IOljl GONGRETE PAVING

! Dl-10.2 h SIT!: FURNISHINGS (61:NC.Hl:S, TA6Ll:S 61KE RACKS, Sl<S,NS, ETC.J

CISMOL.ITION: CONVISY TO OWNIS!=c

I D.2-10111 DRINKIN<S, FOUNTAIN

! D.2-10.2 ~ PLA"l'<S,ROUND EGIUIPMENT

CISMOL.ITION: RISMOVIS ANO DISCARC

I D3-0111 VEGETATION (EXGLUDIN6 TREES,

PROTEC::, T ALL TREES)

! D3-0.2 h PA"l',S,ROUND SURFAGI: TO

- SU66AADI:

I I

I I

I

Dl-10.2

DEMOLITION NOTES

I

I I I

I

I

I I

, I

I I

I

I. CONTRACTOR 15 RESPONSIBLE FOR GeTAINING NECESSARY JURISDICTIONAL PERMITS.

PROVIDE AIR SPADE £XCAVATION

WITI-IIN EXISTING TREE 'PRZ' •

REFER TO TREE PROTECTll)II DETAIL ON SMEET SD50l, DETAIL-B

UNLESS OTIIERWISE NOTED, ALL PAVlf'«., SITE

FURNISI-IINGS (BENCI-IES, TABLES BIKE RACKS, SIGNS,

LIG!lT POLES, ETC.), UTILITY EQUIPMENT, TREES

AND VEGETATION SMALL BE PROTECTED IN PLACE

KENNEDY DRIVE

2. L.t.JLESS OTMER i-llSE NOTED, ALL PAVING, i-lALLS, STRUCTURES, SITE FURNISI-IINGS, VEGETATION, ETC. SllALL BE PROTECTED IN PLACE.

3. ALL ITEMS NOTED TO BE 'REl"Vw'EO" 51-!ALL BE PROPERLY ANO LEGALLY DISPOSED OF, UNLESS NOTED OTIIERi-llSE TO BE SALVAGED, RE-INSTALLED, AND/OR CONVEYED TO OWNER.

~- CONTRACTOR TO VERIFY LOCATION ANO OEPTl-l OF ALL EXISTING UTILITIES PRIOR TO ANY CONSTRUCTION OR EXCAVATION. PROTECT IN Pl.ACE ALL

EXISTING UNOERGROJNO UTILITIES. ANY ADDITIONAL COSTS INCURRED AS A RESULT OF CONTRACTOR'S FAILURE TO VERIFY LOCATIONS OF EXISTING UTILITIES PRIOR TO BEGINHING Of CONSTRUCTION IN TI-IEIR VICINITY SMALL BE BORNE BY TME CONTRACTOR AHO ASSUMED INCLUDED IN TME CONTRACT. CONTRACTOR IS TO VERIFY CONNECTIQ,j POINTS i'IITl-l EXISTING UTILITIES. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED TO EXISTING UTILITIES AND UTILITY STRUCTURES TMAT ARE TO REMAIN. IF CONFLICTS i-llTM EXISTING UTILITIES OCCUR, Tl-IE CONTRACTOR 51-!ALL NOTIFY TME OWNER's REPRESENTATIVE PRIOR TO <DISTRUCTION TO DETERMINE IF ANY FIELD AD.1JSTMENT5 SMOULD BE MADE.

S. CONTRACTOR SllALL VERIFY ALL CONDITIONS IN Tl-IE FIELD AND REPORT ANY DISCREPANCIES TO Tl-IE OWNER'S REPRESENTATIVE.

DI-I0.2

I I I I I

I I

I I

I I I I I

I I / --, , , I I

I I I / , I I I , \ I \ I I I

I I

I I I

I I I I I I

I

' I I

' I ', I -z

I' I I

/\ ----- - I , , I ' 'I

I ' I ' I I \ I I \ I I \ I I \ I I \ I I I \ I

' ___ ..,. -- / --- 7 I

6. ALL CONSTRUCTION SIGNAGE, BARRICADES, TRAFFIC CONTROL DEVICES, ETC., SHALL CONFORM TO THE LATEST EDITIOH OF THE M.U.T.C.D.

CONTRACTOR i-llLL MAINTAIN SUCJ-1 50 Tl-lAT THEY ARE PROPERLY PLACED AND VISABLE AT ALL TIMES.

7. CONCRETE PAVEMENT AND CURB AND GUTTERS SMALL BE DEMOLISl-lED TO Tl-IE NEAREST CONTRACTIOH JOINT, MATCI-IING PLAN AS CLOSELY AS

POSSIBLE.

6, Oi'IHER'S REPRESENTATIVE SllALL BE CONSULTED BEFORE AHY HORK SllALL COMMEHCE.

q_ Tl-IE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING EXISTING IRRIGATION SYSTEM WITHIN Tl-IE PROJECT SCQPE OF WORK DlJRING @ISTRUCTION •

REFER TO NOTES OH IRRIGATION PLANS

SIGN, INC::,LUDING, C.ONC.RETE SLA6

AND FOOTING-S

B KEYPLAN

t:+:+:~ f!Jsl

I

/ -.. _______ ...- I I I I

I I I I I I I ·~ l e I tn

1-w w ::c / .~

I I w tn -w z :: -...I I

I

::c - I- ' <( ., :E ' \

I

C

CD

q' a: CD

C :z:

A. = .... = u -C u, a: ..

a: I- Cl a: >- Cl

II.I w z z z z w 0 :=i.::::

cw, Q 0 en N

*'' " i t i 0 Design, Inc Landscape Architecture & Architectural Sile Design

1 058 E;;ast 21 00 South Salt Lake City, Utah 84106 office 801 . 4B7 . 49.23 fax 801 . 468 . 3046 www.arcsitiodesign.com date: Dec. 16, 2025 revisions

Site Demolition

S0103

I I I I I I I

M l Cl c l en I i~ ~ I w

CJ)

w z -...J :::c

:E:

I I f l ,,.,,,7

'-l -,---- I

I f f f

I I

\ I

' I

I

SCALE t NORTf-1 ARROW A

0 10 20 40

NORTI-I SCALE,

I I

' I

' f \ f I / ,<

DEMOLITION NOTES

PRO,IIDE AIR SPADE EXCAVATION

HITl-ill'I EXISTING TREE 'PRZ' -

REFER TO TREE PROTECTIOl'I DETAIL Of'! SI-IEET SDSOI, DETAIL-B

UNLESS OTMERHISE NOTED, ALL PAVING, SITE

FURNISI-IINGS (BENCI-IES, TABLES BIKE RACKS, SIGNS,

LIGITT POLES, ETC.), UTILITY ECIJIPMENT, TREES

Al'IO VEGETATION SMALL BE PROTECTED IN PLACE

I I

I

I I f

I I I

- --1"- ,,.- I ', /.,. I ' / f I '

/ ! l ' / f \ \

I I \ \ I I \ \ I I \ l I ,/ \ I

I _.,,,..."' ' : ---\-- - , .... , ' I f

I

I. CONTRACTOR 15 RESPOl'ISIBLE FOR GeTAINING NECESSARY JURISDICTIONAL PERMITS.

2. L.t.JLESS 0TI-IER HISE NOTED, ALL PAVING, HALLS, STRUCTURES, SITE FURNISl-ill'IGS, VEGETATIOl'I, ETC, SMALL BE PROTECTED IN PLACE,

3. ALL ITEMS NOTED TO BE 'REl"Vw'E0" SMALL BE PROPERLY AND LEGALLY DISPOSED OF, UNLESS NOTED OTMERHISE TO BE SALVAGED, RE·ll'ISTALLED, Al'ID/OR CONVEYED TO OWNER.

~- CONTRACTOR TO VERIFY LOCATIOl'I ANO DEPTll OF ALL EXISTING UTILITIES PRIOR TO ANY CONSTRUCTIOl'I OR EXCAVATION. PROTECT IN PLACE ALL EXISTING UNDERGRO.JND UTILITIES. ANT ADDITIONAL COSTS INCURRED AS A RESULT OF COl'ITRACTOR'S FAILURE TO VERIFY LOCATIONS OF EXISTING UTILITIES PRIOR TO 6£GINN1NG OF CONSTRUCTIOl'I 11'! TI-IEIR VICll'!ITY SI-IALL BE BORNE BY Tl-IE CONTRACTOR Al'ID ASSUMED INCLUDED IN Tl-IE CONTRACT. CONTRACTOR 15 TO VERIFY CONNECTIQ,j POINTS ~ITll EXISTING UTILITIES. COl'ITRACTOR 15 RESPONSIBLE FOR ANY DAMAGE CAUSED TO EXISTING UTILITIES AND UTILITY STRUCTURES TI-IAT ARE TO REMAIN. IF CONFLICTS HITl-i EXISTING UTILITIES OCCUR, Tl-IE CONTRACTOR SI-IALL NOTIFY Tl-IE OWNER's REPRESENTATIVE PRIOR TO CONSTRUCTION TO DETERMINE IF AN'r FIELD AD..USTMENT5 51-IClULD BE MADE.

S. CONTRACTOR SMALL VERIFY ALL CONDITION5 IN TllE FIELD AND REPORT Al'IY DISCREPANCIES TO Tl-IE OWNER'S REPRESENTATIVE.

I

I I I I I

I I f

REFERENCE SCf-lEDULE NOTES CODE:. D5SCl<IP110N

D5MOL.ITION: Pl<OT5CT-IN-PL.AC5

!DI-IOljl C.ONC.RETE PAVINc&

! Dl-1O2 ~ SITE FURNISHINGS (BENCHES, TABLES BIKE RACKS, Slc&NS, ETC.J

D5MOL.ITION: CONVE"I"' TO OWN51<

I D.2-1O111 DRINKING, FOUNTAIN

I D.2-10211 PLAYc&ROUND EQUIPMENT

D5MOL.ITION: 1<5MOV5 AND DISCAl<D

VEGiETATION (EXC.LUDINc:, TREE&, PROTEC. T ALL TREES)

! D:1-O2 ~ PAYc&ROUND SURFACE TO , SUl3cSiRADE

! D:1-OS ~ SIGN, INC,LUDINc:, C,ONC,RETE SLAB

, AND FOOTING&

I I I

I

\ I \ \ I

\ I \ I \ f \ f I I I f

I /

\ - J'

I

I

' I I I

I I f --- -- // i-,,D,,.1•~1~0,..,2=->l ' f ---f f

.... ___ -~ ,,,......,.,,-..J

I I I I

I --- I

- f ~, I I

DS-O1

+ I +

A + f

I f f

I I I I I I

I f

I

I I I I

I f I

6, ALL CONSTRUCTION SIGNAGE, BARRICADES, TRAFFIC CONTROL DEVICES, ETC., SI-IALL CONFORM TO Tl-IE LATEST EDITION OF Tl-IE M.U.T.C.D.

CONTRACTOR HILL MAll'ITAIN SUCl-1 50 Tl!AT TI-IEY ARE PROPERLY PLACED Al'ID VISABLE AT ALL TIMES, I I I I

I I

I I I I I

I

7. CONCRETE PAVEMENT AND CURB ANO GUTTERS SMALL BE DEMOLISI-IED TO TllE NEAREST CONTRACTION JOINT, MATClllNG PLAl'I AS CLOSELY AS

POSSIBLE.

6, QIIIHER'S REPRESENTATIVE SMALL BE CONSULTED BEFORE ANY HORI; SMALL ca'IMENCE.

I f I I I f f f

I

I

I ,, B q_ TllE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING EXISTING IRRIGATION SYSTEM WITI-IIN TllE PROJECT SCQPE OF WORK DlJRING @ISTRUCTION •

REFER TO NOTES ON IRRIGATION PLANS

I I I

-- f ', I

\ f ,, KEYPLAN

DI-IOI

C

CD

q' a: CD

C :z:

A. = .... = u -C u, a: ..

a: I- Cl a: >- Cl

II.I w z z z z w :=i.:::: 0 cw, Q 0 en N

*'' " i t i 0 Design, Inc Landscape Architecture & Architectural Sile Design

1 058 E;;ast 21 00 South Salt Lake City, Utah 84106 office 801 . 4B7 . 49.23 fax 801 . 468 . 3046 www.arcsitiodesign.com date: Dec. 16, 2025 revisions

Site Demolition

S0104

I ----.i_ \

MATCH LINE SEE SHEET SD101 ------- -- - --- - ------

REFERENCE SC~EDULE NOTES

CODE:. DE:.SC!<IFilON

DE:.MOl..lTION: FROTE:.CT-IN-Ft.A.CE:.

I DI-IOI g GONGRETE PAVING, I c,1-10211 SITE FURNISHINGS (BENGHES, TAElL.l:S 61KE RAGKS, SIGNS, ETC.J

DE:.MOl..lTION: CONVE:."T" TO OWNE:.!<

! D2-IOI ~ DRINKING FOUNTAIN

I c,2-10211 PL.AY'GROUND EQUIPMENT

DE:.MOl..lTION: !<E:.MOVE:. AND DISCA!<D

I D5-0I 11 VEGETATION (EXGL.UDIN6 TREES,

PROTEG T AL.I. TREES)

I DS-0211 PAY'GROUND SURFAGE TO

.. SUB6RADE

I DS-05 II SIGN, INGL.UDING C.ONGRETE SL.A6

AND FOOTIN6!:>

t:+:+:1 V!}J¼I

SCALE t NORT~ ARROW A DEMOLITION NOTES

NORTI-I SCAL.E,

I. CONTRACTOR IS RESPONSIBLE FOR OBTAINING NECESSARY JURISDICTIONAL PERMITS.

2. IJ<JLESS OTllER l'llSE NOTED, ALL PAVING, l'lALLS, STRUCTURES, SITE FURNISI-IINGS, VEG.ETATION, ETC. 51-lALL BE PROTECTED IN PLACE.

3. ALL ITEMS IIOT"ED TO BE 'REl"V,'EO" 51-lALL BE PROPERLY ANO LEG.ALLY DISPOSED OF, UNLESS NOTED Ofl.lERlollSE TO BE SALVAG.EO, RE-INSTALLED, AND/OR CONVEYED TO OWNER.

~- CONTRACTOR TO VERIFY LOCATION ANO OEPTll OF ALL EXISTING UTILITIES PRIOR TO ANY CONSTRUCTION…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .